0% found this document useful (0 votes)
46 views226 pages

DSR Vol 2 Civil (1) - Output

The Delhi Schedule of Rates (DSR) Volume II for 2023 is a comprehensive technical document published by the Central Public Works Department, detailing various rates for civil works. This edition incorporates updates based on current market rates, labor wages, and GST revisions, and includes new items while removing outdated ones. The DSR serves as a crucial resource for engineers, architects, and contractors in the building construction industry.

Uploaded by

Shrihari Nagar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
46 views226 pages

DSR Vol 2 Civil (1) - Output

The Delhi Schedule of Rates (DSR) Volume II for 2023 is a comprehensive technical document published by the Central Public Works Department, detailing various rates for civil works. This edition incorporates updates based on current market rates, labor wages, and GST revisions, and includes new items while removing outdated ones. The DSR serves as a crucial resource for engineers, architects, and contractors in the building construction industry.

Uploaded by

Shrihari Nagar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 226

3Tf5T

Central Public Works Depačment

Delhi Schedule of Rates


Volume - II
2023
GOVERNMENT OFINDIA

CENTRAL PUBLIC WORKS DEPARTMENT

DELHI SCHEDULE RATES


(Vol. 2)

2023

RblishedunderlheAuthorilyofDirectorGeneiol, CP¥/DoNerDelhi
Central Public Works Department
Nirman Bhawan, New Delhi- 110011
Rajesh Kumar Kaushal Tel: 23062556/ 1317, Fax : 23061884
Director General E-Mail: cpwd [email protected]

FOREWORD
Delhi Schedule of Rates published by Central Public Works Department isa
comprehensive and useful technical document of various items used for execution of civil
works. In addition to CPWD, theSchedule of Rates are used by many Central and State
Government Departments, Institutions, Public Sector Undertakings, Architects and
Contractors.
Delhi Schedule of Rates was first published in the year 1931, followed by numerous
revisions/publications from time to time in order to bring it in line with the prevailing new
building materials, current technologies, market rates and for implementation of revised tax
regimes. It was revised in 1977, 1981, 1985, 1989, 1993, 1997, 2002, 2007, 2010 (Reprint),
2012, 2013, 2014, 2016, 2019 and 2021.

The last edition of Delhi Schedule of Rates was published in the year 2021 and its revision
had become necessary owing to:
a) Provision contained in CPWD Manual to revise it after every two years.
b) Incorporating Corrections in items which issued through correction slip No.1 to21.
c) Revision of GST rates on works from 12% to 180 w.e.f 18.07.2022.
I wish to place on record the technical input and effective coordination provided by
Shri Dharmesh Chandra Goel, ADG (Tech.), Shri Prem Mohan CE/CSO (Civil),
Shri Vinayak Rai and the sincere efforts put in by Shri D.K. Ujjainia SE (TAS),
Shri M. Seetarama Rao, Shri S.N. Jaiswal EE(TAS), Shri Durga Ram Chowdhary AE(TAS),
Shri Akhileshwar Shah, Chief Estimator and the entire team of officers in CSO unit in
preparing and finalizing the DSR 2023, ina short and time bound frame.
I am sure that CPWD Delhi Schedule of Rates 2023 will be useful to all the engineers,
architects and contractors in Building Construction Industry in general, and CPWD in
particular.

Place: New Delhi (Rajesh Kumar Kaushal)


Date: July 12, 2023 Director General

III
110011
Dharmesh Chandra Goel Central Public Works Department
Addl. Director General (Tech) Nirman Bhawan, New Delhi- 110011
Tel: 23063389, Fax: 23061833
E-Mail: [email protected]

PREFACE
1. Delhi Schedule of Rates usually calle‹1 as DSR is update‹1 as DSR-2023 andincludes
existing items of DSR 202l with deletion of few items which notin use now a days
& addition of some new items in line with emerging trends in the Construction
Industry.
DSR 2023 is based on theprevailing irai'ket rates of materials in Delhi eluting the month
of April 2023.The labour rutes adopted are as per’ minimum rate of wages applicable
with etfect from 01.04.2023 issued by Chief Labour Comnfissioner. Govt. ot India/
Commissioner’ (Labour), Govt. of Delhi, whichevei’ is higher.
The cost index forDSR 2023 is 107 with reference to CPWD Delhi Plinth Area Rates
2021, having base 100 as on 01.04.2021
4. The technical sanctioning authority may decide i'ates of non-scheduled items
judiciously, based on market i'ates without adding cost index. The description of such
items along with analysis ot rates and specifications may be shared with CSQ for
inclusion in next DSR.
5. This DSR 2023 shall be read along with CPWD Specifications 2019 Vol.-I& d with up
to date correction slips.
6. The salient Features ot DSR 2023 arcas follows:
6.1 DSR 2023 isI ilingual in two volumes. In case of any discrepancy between
English and Hindi versions, the English version will prevail.
6.2 The effect of GST l8^â on works contract has been incorporated in all items.
7. Major modifications in the fomi of correction in nomenclature of items. deletion ot
misleading content etc. have been undertaken.
8. Wholeheai‘tcd commitment and considerable efforts have been pur for preparation
of this edition ot Delhi Schedule of Rates.I convey my deep appi‘eciation and sincere
thanks to: Shri Pi'em Mohan, CE, CSQ (Civil), Shri Vinayak Rai. Shri Dinesh Kumar
Ujjainia, SE (TA S), Shri M. Seetai'ania Rao, Shri S.N. Jaiswal EE (TAS),

II*
Shri Akhileshwar SahSah Chief
ChiefEstimator(TAS),
Estimator (TAS), Shri Durga Ram
Ram Chowdhary, AE AE (TAS),
Shri Gian Chand Singla, AE AE (TAS), Shri Hemant Panrui, AE AE (TAS), Shri Raghvendra,
AE
AE (TAS) andandShri
Shri A.K. JhaAD
Jha AD (OL) and histeam
his team forthetranslation
for the translation of DSR- 2023 inin
Hindi and Shri Kamal Passi, Assistant Architect for design of cover page and other
officers and
and staff of
of CSQ
CSQ unit whose names are arenotmentioned
not mentioned here forthe
for the sake brevity
for their sincere efforts put
put in the
the preparation of this document insucha
in such a short time.
CSQ
CSQ unit is indebted forthe & immense contribution for their substantial inputs
for the support &
by
by various individuals and and field units for providing suggestions.
9. I I convey my
my gratitude to committees members under the the chairmanship of CE CE
(NDZ-I), CE
CE (NDZ-II), CECE (NDZ-III) &
& CE
CE Flyover Zone at Delhi who
who provided the
market rates of material to CSQ
CSQ which enabled CSQ
CSQ to come outwith
out with this edition of
DSR
DSR 2023
10.
10. Although, due
due care has
has been taken in bringing out DSR-2023, still there is possibility that
some errors are left inadvertently. Errors&
Errors & omission may
may be brought to the the notice of
Superintending Engineer(TAS),
Engineer (TAS), CPWD, RoomNo.
Room No. 418, A-wing, Nirman Bhawan, New New
Delhi -110011 delsetascsq.cpwdHnic.in/
[email protected] / cecsq.cpwdHnic.in
[email protected]

Suggestions from everyone who


who areusing
are using this document are
arewelcome
welcome asthese
as these have
scope for
for further improvement.
improvement.

Dharmesh Chandra Goel


ADG(Tech) CPWD

V
CO NTENTS

SH.No. NAMEOF SUB-HEAD PAGE No.

A. BASIC RATES

0.1 HIRE CHARGES OF PLANTS& MACHINERY 3

0.2 LABOUR 7

0.3 MATERIALS 9

B. SUB -HEADS

1. Carriage of Materials 79

2. Earth Work 89

3. Mortar 97

4. Concrete Work 1 01

5 Reinforced Cement Concrete 111

6. Masonry Work 1 25

7. Stone Work 131

8. Cladding Work 137

9. Wood andPVC Work 145

10. Steel Work 181

11. Flooring 187

12. Roofing 199


SH.No. NAMEOF SUB-HEAD PAGE No.

13 Finishing 215

14 Repairs to Building 227

15 Dismantling and Demolishing 237

16 Road Work 245

17 Sanitary Installations 263

18 Water Supply 277

19 Drainage 307

20 Pile work 317

21 Aluminium Work 323

22 Water Proofing 329

23 Rain Water Harvesting& Tubewells 337

24 Conservation of Heritage Buildings 343

25 Structural Glazing Aluminium Composite Panel 347

26 New Technologies and Materials 353

C. CEMENT CONSUMPTION STATEMENT 381

D. BITUMEN CONSUMPTION STATEMENT 423

Note: For Sub Heads1 to 12 refer Vol.1

1’III
DELHI SCHEDULE OF RATES
(Vol. 2)

fnY
n yh nj
fnYyh n vuq
vulq wph
l
¼Hkkx 2½
¼H kkx - 2)
2023
SUB HEAD
SUB HEAD:: 13.0
FINISHING
13.0 FINISHING

Code No Description Unit Rate


Note :- Rates forexternal
for external plastic are
are for height upto 10m
10m from ground level
in less otherwise stated.
(INFINE SAND)
CEMENT PLASTER (IN
13.1
13.1 12 mm
12 mm cement plaster of mix
mix ::
13.1.1
13.1.1 11:4
:4 (1
(1 cement:
cement:44 fine
fine sand)
sand) sqm
sqm 347.05
13.1.2 11:6
:6 (1
(1 cement:
cement:66 fine
fine sand)
sand) sqm
sqm 333.35
13.2 15 mm
15 mm cement plaster on the
on the rough side of single or half brick wall of mix
mix ::
13.2.1
13.2.1 1:4
1:4 (1
(1 cement:
cement:44 fine
fine sand)
sand) sqm
sqm 399.45
13.2.2 1:6
1:6 (1
(1 cement:
cement:66 fine
fine sand)
sand) sqm
sqm 383.00
13.3 20 mm
20 mm cement plaster of mix
mix ::
13.3.1
13.3.1 1:4
1:4 (1
(1 cement:
cement:44 fine
fine sand)
sand) sqm
sqm 471.35
13.3.2 1:6
1:6 (1
(1 cement:
cement:66 fine
fine sand)
sand) sqm
sqm 450.00
(INCOARSE SAND)
CEMENT PLASTER (IN
13.4 12 mm
12 mm cement plaster of mix
mix ::
13.4.1
13.4.1 1:4
1:4 (1
(1 cement:
cement:44 coarse
coarse sand)
sand) sqm
sqm 357.35
13.4.2 1:6
1:6 (1
(1 cement:
cement:66 coarse
coarse sand)
sand) sqm
sqm 343.65
13.5 15 mm
15 mm cement plaster on
on rough side of single or half brick wall of mix:
13.5.1
13.5.1 1:4
1:4 (1
(1 cement:
cement:44 coarse
coarse sand)
sand) sqm
sqm 411.75
13.5.2 1:6
1:6 (1 cement: 6 coarse
(1 cement:6 coarse sand)
sand) sqm
sqm 395.35
13.6 20 mm cement plaster of mix
20 mm mix ::
13.6.1
13.6.1 1:4
1:4 (1 cement: 4 coarse
(1 cement:4 coarse sand)
sand) sqm
sqm 487.40
13.6.2 1:6
1:6 (1 cement: 6 coarse
(1 cement:6 coarse sand)
sand) sqm
sqm 466.05
CEMENT PLASTER WITHA
WITH A FLOATING COAT OF NEAT CEMENT
13.7 12
12 mm
mm cement
cement plaster finished witha
plaster finished with a floating
floating coat
coat of
of neat cement ofmix
neat cement of mix::
13.7.1
13.7.1 1:3
1:3 (1 cement: 3 fine
(1 cement:3 fine sand)
sand) sqm
sqm 439.25
13.7.2 1:4
1:4 (1 cement: 4 fine
(1 cement:4 fine sand)
sand) sqm
sqm 425.55
13.8 15
15 mm
mm cement
cement plaster on rough
plaster on rough side
side of single or
of single or half
half brick wall finished
brick wall finished
with a floating
witha floating coat
coat of
of neat cement ofmix
neat cement of mix::
13.8.1
13.8.1 1:3
1:3 (1 cement: 3 fine
(1 cement:3 fine sand)
sand) sqm
sqm 494.30
13.8.2 1:4
1:4 (1 cement: 4 fine
(1 cement:4 fine sand)
sand) sqm
sqm 477.90
13.9 Cement
Cement plaster
plaster 1:3
1:3 (1 cement: 3 coarse
(1 cement:3 sand) finished
coarse sand) finished witha
with a floating
floating coat
coat
of
of neat cement.
13.9.1
13.9.1 12 mm
12 mm cement plaster sqm
sqm 449.55
13.9.2 20 mm
20 mm cement plaster sqm
sqm 587.20
13.10 15
15 mmmm cement
cement plaster
plaster 1:3
1:3 (1
(1 cement:
cement: 33 coarse sand) finished
coarse sand) finished witha
with a
floating coat
floating of neat
coat of neat cement
cement onon therough
the rough side of single
side of single or
or half
half brick wall.
brick wall. sqm
sqm 506.60
CEMENT PLASTER IN INTWO
TWO COATS
13.11
13.11 18 mm
18 mm cement plaster in twotwo coats under layer 12 12 mm
mm thick cement plaster
1:5
1:5 (1 cement : 5 coarse
(1 cement:5 coarse sand) finished witha
sand) finished with a top
top layer
layer66 mm thick cement
mm thick cement
plaster
plaster 1:6
1:6 (1 cement :6 6 fine
(1 cement: fine sand).
sand). sqm
sqm 518.55
13.12 mm cement plaster in two
18 mm two coats under layer 12 12 mm
mm thick cement plaster
1:5
1:5 (1 cement :5 5 coarse
(1 cement: coarse sand) and a top
sand) anda top layer
layer66 mm thick cement
mm thick cement plaster
plaster
1:3
1:3 (1 cement : 3 coarse
(1 cement:3 coarse sand) finished rough
sand) finished with sponge.
rough with sponge. sqm
sqm 537.45

sua HeAD
SUB HEAD:: 13.0
13.0 FiNisHiNG
FINISHING 217
Code No Description Unit Rate
13.13 12
12 mm
mm cement
cement plaster
plaster 1:2
1:2 (1
(1 cement : 2 stone
cement:2 dust).
stone dust). sqm
sqm 378.70
13.14 15
15 mm
mm cement
cement plaster
plaster 1:2
1:2 (1
(1 cement
cement::2 2 stone dust) on
stone dust) on the
the rough side of
rough side of
single or half brick wall. sqm
sqm 437.20
13.15 20
20 mm
mm cement
cement plaster
plaster 1:2
1:2 (1
(1 cement : 2 stone
cement:2 stone dust).
dust). sqm
sqm 520.55
66 mm
mm CEMENT PLASTER
13.16 66 mm
mm cement plaster of mix
mix ::
13.16.1
13.16.1 1:3
1:3 (1
(1 cement : 3 fine
cement:3 fine sand)
sand) sqm
sqm 300.45
13.17 66 mm
mm cement
cement plaster
plaster 1:3
1:3 (1
(1 cement
cement::3 3 fine
fine sand)
sand) finished
finished witha
with a floating
floating
coat of
of neat cement and thick coat of of Lime wash on topofwalls
top of walls when dry dry
for
for bearing of R.C.C. slabs and and beams. sqm
sqm 396.65
13.18 Neat cement punning. sqm
sqm 79.95
ROUGH CAST PLASTER
13.19 Rough cast plaster upto 10 m m height above ground level witha with a mixture
of sand and gravel or crushed stone from6 from 6 mm mm to to 10 mmmm nominal size,
dashed over and and including thethe fresh plaster in two two layers, under layer 12 12
mm cement plaster
mm cement plaster 1:4
1:4 (1 cement : 4 coarse
(1 cement:4 coarse sand)
sand) and top layer
and top layer 10
10 mm
mm
cement
cement plaster
plaster 1:3
1:3 (1 cement : 3 fine
(1 cement:3 fine sand)
sand) mixed with 10%
mixed with finely grounded
10% finely grounded
hydrated lime by by volume ofcement.
of cement.
13.19.1
13.19.1 Ordinary cement finish
Ordinary cement finish using
using ordinary
ordinary cement
cement sqm
sqm 886.60
PEBBLE DASH PLASTER
13.20 Pebble dash plaster upto 10 m m height above ground level witha with a mixture of
washed pebble or crushed stone6 stone 6 mm mm toto 12.5 mm mm nominal size, dashed
and including fresh plaster in two
over and two layers under layer 12 12 mm
mm cement
plaster
plaster 1:4
1:4 (1
(1 cement
cement:4: 4 coarse
coarse sand) and top
sand) and top layer
layer 1010 mm
mm cement
cement plaster
plaster
with cement
with cement mortar
mortar 1:3
1:3 (1
(1 cement
cement::3 3 finefine sand)
sand) mixed with 10%
mixed with finely
10% finely
grounded hydrated lime by by volume of ofcement.
cement. sqm
sqm 829.95
13.21
13.21 Extra for providing
Extra for providing and
and mixing water proofing
mixing water proofing material
material in in cement
cement plaster
plaster per bag
bag
work in proportion recommended by by themanufacturers.
the manufacturers. of50kg
of 50kg
cement
used in
the mix
the mix 22.10
13.22 Extra for
for plastering exterior walls of height more than 10 m
m from ground
level for every additional height of33 m
m or part thereof. sqm
sqm 87.10
13.23 Extra for on circular work not
for plastering on notexceeding6 m in radius:
exceeding 6 m
13.23.1
13.23.1 In one
one coat sqm
sqm 47.65
13.23.2 In two
two coats sqm
sqm 72.30
13.24 Extra for
for plastering done on moulding, cornices or architraves including
neat finish to
neat finish to line and level:
line and level:
13.24.1
13.24.1 In one
one coat sqm
sqm 713.20
13.24.2 In two
two coats sqm
sqm 1175.75
13.25 Extra for plastering:
for plastering:
13.25.1
13.25.1 Spherical ceiling sqm
sqm 177.60
13.25.2 Groined ceiling sqm
sqm 192.30
13.25.3 Flewing soffits
Flewing soffits sqm
sqm 117.65
13.26 and applying plaster of paris putty of2
Providing and mm thickness over
of 2 mm
plastered surface to prepare the surface even and smooth complete. sqm
sqm 262.70
ARTIFICIAL STONE PLASTER
13.27 Extra for
for lining out
out plaster to imitate stone or concrete blocks walling. sqm
sqm 113.90

218
218 SUB HEAD:: 13.0 FINISHING
SUB
Code No Description Unit Rate
PLAIN CEMENT MORTAR BANDS
13.28 mm thick plain cement mortar bands in cement mortar 1:4
12 mm 1:4 (1
(1 cement:
cement :
44 fine
fine sand):
sand):
13.28.1
13.28.1 Flush Band cm per
cm per
metre 7.50
13.28.2 Sunk Band cm per
cm
metre 8.20
13.28.3 Raised Band cm per
cm
metre 9.35
13.28.4 Moulded Band cm per
cm
metre 16.10
13.29 mm thick plain cement mortar band in cement mortar 1:4
18 mm 1:4 (1
(1 cement:4
cement : 4
fine sand):
fine sand):
13.29.1
13.29.1 Flush Band cm per
cm
metre 9.05
13.29.2 Sunk Band cm per
cm
metre 10.00
13.29.3 Raised Band cm per
cm per
metre 11.40
13.29.4 Moulded Band cm per
cm
metre 21.40
13.30 mm thick moulded cement mortar band in two
18 mm two coats under layer 12 12 mm
mm
thick with
thick with cement
cement mortar
mortar 1:5
1:5 (1
(1 cement
cement::5 5 coarse
coarse sand) top layer
sand) top layer66 mm
mm cm per
cm per
thick with
thick with cement
cement mortar
mortar11:4
:4 (1
(1 cement
cement:4: 4 fine
fine sand).
sand). metre 21.45
POINTING ON ON BRICK WORK
13.31
13.31 Pointing
Pointing onon brick work or
brick work or brick flooring with
brick flooring with cement
cement mortar
mortar11:3
:3 (1 cement
(1 cement
:33 fine
fine sand):
sand):
13.31.1
13.31.1 Flush// Ruled/ Struck or weathered pointing
Flush sqm
sqm 257.35
13.31.2 Raised and
and cut
cut pointing sqm
sqm 419.90
POINTING ON ON TILE BRICK WORK
13.32 Pointing
Pointing on tile brick
on tile work with
brick work with cement
cement mortar
mortar11:3
:3 (1 cement : 3 fine
(1 cement:3 fine sand):
sand):
13.32.1
13.32.1 Flush/ Ruled/ Struck or weathered pointing sqm
sqm 350.20
POINTING ON ON STONE WORK WORK
13.33 Pointing on stone
Pointing on stone work
work with
with cement
cement mortar
mortar 1:3
1:3 (1
(1 cement : 3 fine
cement:3 fine sand):
sand) :
13.33.1
13.33.1 Flush/ Ruled pointing sqm
sqm 385.40
13.33.2 Raised and
and cut
cut pointing sqm
sqm 701.05
13.34 and cut
Raised and cut pointing on
on stone work in white cement mortar 1:3
1:3 (1
(1 white
cement : 3 marble
cement:3 dust).
marble dust). sqm
sqm 716.95
13.35 Pointing
Pointing on stone slab
on stone ceiling with
slab ceiling with cement
cement mortar
mortar 1:2
1:2 (1 cement :2 2 fine
(1 cement: fine
sand):
sand):
13.35.1
13.35.1 Flush/ Ruled pointing sqm
sqm 214.20
13.36 Extra for
for pointing on
on walls on
on the outside at height more than 10 m
m from
ground level for every additional
additional height of33 m
m or part there of. sqm
sqm 8.65
INTERIOR FINISHING
13.37 White washing with lime to give an
an even shade:
shade :
13.37.1
13.37.1 New work (three
New work or more
(three or coats)
more coats) sqm
sqm 39.05
13.38 Satna lime wash on walls with one
one coat. sqm
sqm 15.75

sua HeAD
SUB HEAD:: 13.0
13.0 FiNisHiNG
FINISHING 219
219
Code No Description Unit Rate
13.39 Colour washing such
Colour washing as green,
such as green, blue or buff
blue or to give
buff to give an
an even
even shade
shade::
13.39.1
13.39.1 New work (two
New work or more
(two or more coats) with aa base
coats) with base coat
coat ofof white
white
washing with lime sqm
sqm 53.30
13.39.2 New work (two
New work or more
(two or coats) witha
more coats) with a base coat of
base coat of whiting
whiting sqm
sqm 52.75
13.41
13.41 Distempering with 1st
Distempering with quality acrylic
1st quality distemper (ready
acrylic distemper (ready mixed)
mixed) having VOC
having VOC
content less than 50
50 gram/litre,
gram/litre, of approved manufacturer and and ofof required
shade and colour all complete to to achieve even shade and colour
colour::
13.41.1
13.41.1 New work (two
New work or more
(two or coats) over
more coats) over and
and including water
including water
thinnable priming
thinnable priming coat with cement
coat with cement primer
primer having VOC content
having VOC content
less than 5050 gram/litre sqm
sqm 185.65
EXTERIOR FINISHING
13.44 Finishing walls with
Finishing walls with water
water proofing cement paint
proofing cement paint of
of required shade :
required shade:
13.44.1
13.44.1 New work (Two
New work (Two or
or more coats applied
more coats applied@@ 3.84
3.84 kg/10 sqm)
kg/10 sqm) sqm
sqm 116.90
13.45 Finishing walls with textured exterior paint of required shade:
shade :
13.45.1
13.45.1 New work (Two
New work (Two oror more coats applied
more coats applied @@ 3.283.28 ltr/10 sqm)
Itr/10 sqm)
over and
and including priming coat ofof exterior primer applied@
applied @
2.20kg/10 sqm
sqm sqm
sqm 223.60
13.46 Finishing walls with Acrylic Smooth exterior paint of required shade:
shade :
13.46.1
13.46.1 New work (Two or
New or more coat applied@ Itr/10 sqm
applied @ 1.67 ltr/10 sqm over
and
and including priming coat of of exterior primer applied
applied@@ 0.90
litre/10 sqm)
litre/10 sqm) sqm
sqm 160.60
13.47 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone
additives of required shade:
13.47.1
13.47.1 New work (Two or
New or more coats applied@ Itr/10 sqm
applied @ 1.43 ltr/10 sqm over
and
and including priming coat of of exterior primer applied
applied@@ 0.90
litre/10 sqm)
litre/10 sqm) sqm
sqm 171.10
13.48 Finishing with Deluxe Multi surface paint system forinteriors
for interiors and
and exteriors
using
using Primer
Primer as
as per
per manufacturers
manufacturers specifications
specifications::
13.48.1
13.48.1 Two
Two or more coats applied on on walls@ Itr/10 sqm
walls @ 1.25 ltr/10 sqm over
and
and including one
one coat ofof Special primer applied
applied@@ 0.75 ltr Itr
/10
/10 sqm
sqm sqm
sqm 193.70
13.48.2 Painting wood work with Deluxe Multi Surface Paint of required
shade. Two
Two or more coat applied
applied@@ 0.90 ltr/10
Itr/10 sqm
sqm over anan
under coat of primer applied @0.75 ltr/10 Itr/10 sqm
sqm of of approved
brand and
and manufacture sqm
sqm 176.25
13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an an
even shade. Two
Two or more coat applied
applied@@ 0.90 ltr/10
Itr/10 sqm
sqm over
an
an under coat ofof primer applied@ Itr/10 sqm
applied @ 0.80 ltr/10 sqm of of approved
brand and
and manufacture sqm
sqm 170.70
13.48A Finishing walls with ready mixed Premium acrylic emulsion paint (Company
Depot Tinted) having
Depot Tinted) VOC less
having VOC than 50
less than 50 gm/litre and UV
gm/litre and UV resistance as per
resistance as per
15489:2004, Alkali&
IS 15489:2004, Alkali & fungal resistance,
resistance, dirt resistance exterior paint of
required shade with silicon additives.
13.48A.1
13.48A.1 New work (Two or
New or more coats applied@ 10 sqm
applied @ 1.43 litre/ 10 sqm
over and
and including priming coat ofof exterior primer applied
applied@@
0.90 litre/10 sqm. sqm
sqm 181.25
13.50 Applying priming coat:
13.50.2 With ready mixed aluminium primer of of approved brand andand
manufacture on on resinous wood and
and plywood sqm
sqm 74.65

220
220 SUB HEAD:: 13.0 FINISHING
SUB
Code No Description Unit Rate
13.50.3 With ready mixed red red oxide zinc chromate primer of approved
and manufacture on
brand and on steel galvanised iron/ steel works sqm
sqm 67.40
13.50.4 With ready mixed red red oxide zinc chromate primer of approved
brand
brand and
and manufacture
manufacture onon steel work (second
steel work (second coat)
coat) sqm
sqm 36.10
13.51
13.51 Painting with silicon
silicon& & acrylic emulsion based water thinnable sealer of
approved brand and and manufacture on on wet or patchy portion of plastered
surfaces::
surfaces
13.51.1
13.51.1 One coat
One sqm
sqm 101.70
13.51.2 Two
Two coats sqm
sqm 161.70
13.52 Finishing with Epoxy
Finishing with Epoxy paint
paint (two or more
(two or more coats)
coats) at all locations
at all locations prepared
prepared
and
and applied
applied asas per
per manufacturer’s specifications including
manufacturer's specifications including appropriate
appropriate
priming coat, preparation of surface, etc. complete.
13.52.1
13.52.1 On steel work
On sqm
sqm 241.75
13.52.2 On concrete work
On sqm
sqm 235.15
13.53 Painting on
on G.S. sheet with synthetic enamel paint of approved brand and
and
of required colour to give an
manufacture of an even shade:
shade :
13.53.1
13.53.1 New work (two
New work or more
(two or more coats)
coats) including
includingaa coat
coat ofof approved
approved
steel primer but excludinga
excluding a coat of
of mordant solution sqm
sqm 180.85
13.54 Applyinga
Applying a coat of
of mordant solution on
on G.S. sheet:
13.54.1
13.54.1 Witha 38 gms
With a solution of 38 gms of copper acetate in ina a litre of
of soft
water sqm
sqm 63.35
13.54.2 Witha
With a solution made of 13 gms of
of 13 of hydrochloric acid in ina a
solution of 13
13 gms
gms each ofcopper
of copper chloride, copper nitrate andand
ammonium chloride dissolved in ina a litre of
of soft water sqm
sqm 63.05
13.55 Painting
Painting (two
(two or
or more
more coats) on rain
coats) on water, soil
rain water, waste and
soil waste vent pipes
and vent pipes and
and
fittings with
fittings with black
black anticorrosive
anticorrosive bitumastic
bitumastic paint
paint of approved brand
of approved and
brand and
manufacture, over and
manufacture, includingaa priming of ready mixed zinc chromate
and including
yellow primer onon new
new work:
13.55.1
13.55.1 100 mm
100 mm diameter pipes metre 76.35
13.55.2 150 mm
150 mm diameter pipes metre 113.80
13.56 Painting
Painting (two
(two or
or more
more coats) on rain
coats) on water, soil
rain water, soil waste
waste and vent pipes
and vent pipes and
and
fittings with
fittings with synthetic
synthetic enamel
enamel paint of approved
paint of approved brand and manufacture
brand and manufacture
and
and required colour overa
over a priming coat of
of approved steel primer on new
on new
work.
13.56.1
13.56.1 100 mm
100 mm diameter pipes metre 82.00
13.56.2 150 mm
150 mm diameter pipes metre 122.15
13.57 Paintting with oil type wood preservative of approved brand and
and
manufacture:
manufacture:
13.57.1
13.57.1 New work (two
New work or more
(two or more coats)
coats) sqm
sqm 54.40
13.58 Providing
Providing and
and applying two coats
applying two coats of
of fire
fire retardant
retardant paint on cleaned
paint on cleaned wood
wood
// ply
plysurface@ sqm per litre per
surface @ 3.5 sqm per coat including preparation of base
surface as per
surface as per recommendations
recommendations of manufacturer to
ofmanufacturer to make the surface fire
make thesurface fire
retardant. sqm
sqm 334.50
13.59 Coal tarring two
two coats on new work using 0.16 Litre and
on new and 0.12 litre coal tar
tar
per
per sqm
sqm in the first
in the first coat
coat and
and second coat respectively.
second coat respectively. sqm
sqm 66.90
13.61
13.61 Factory made 50mmx47 mm mm witha
with a wall thickness of5 mm door frame
of 5 mm
PVC
PVC extruded
extruded sheet
sheet including
including carriage
carriage
13.61.1
13.61.1 Two
Two or more coats on new work
on new sqm
sqm 155.90

sua HeAD
SUB HEAD:: 13.0
13.0 FiNisHiNG
FINISHING 221
221
Code No Description Unit Rate
13.62 Painting with synthetic enamel paint of approved brand and
and manufacture
of required colour to give an
of an even shade:
shade :
13.62.1
13.62.1 Two
Two or more coats on new work over an
on new an under coat of
of suitable
shade with ordinary paint of approved brand and and manufacture sqm
sqm 226.25
13.63 Painting with aluminium paint of approved brand and and manufacture toto give
an even shade
an shade..
13.63.1
13.63.1 Two
Two or more coats on new work
on new sqm
sqm 146.80
13.64 Painting with acid proof paint of approved brand and and manufacture of of
required colour to give anan even shade:
shade :
13.64.1
13.64.1 Two
Two or more coats on new work
on new sqm
sqm 163.35
13.65 Painting with black anti-corrosive bitumastic paint of approved brand and and
manufacture toto give an
an even shade:
shade :
13.65.1
13.65.1 Two
Two or more coats on on new
new work sqm
sqm 140.25
13.67 Varnishing with
Varnishing with varnish
varnish ofof approved
approved brand and manufacture
brand and manufacture::
13.67.1
13.67.1 Two
Two or more coats of glue sizing with copal varnish over an
under
under coat
coat ofof flatting
flatting varnish
varnish sqm
sqm 233.80
13.67.2 Two
Two or more coats glue sizing with spar varnish or an an under
coat of
coat of flatting
flatting varnish
varnish sqm
sqm 236.90
13.68 polishing::
French spirit polishing
13.68.1
13.68.1 Two or
Two or more coats on
more coats on new works including
new works includingaa coat
coat ofwood
of wood filler
filler sqm
sqm 446.25
13.69 on wood work with ready mixed wax
Polishing on wax polish of approved brand
and manufacture
and manufacture::
13.69.1
13.69.1 New work
New sqm
sqm 197.65
13.70 Floor
Floor polishing on masonry
polishing on masonry or concrete floors
orconcrete floors with
with wax
wax polish
polish of approved
of approved
and manufacture.
brand and manufacture. sqm
sqm 96.10
13.71
13.71 Lettering with black Japan paint of approved brand and
and manufacture per letter
per cm
per cm
height 6.15
13.72 Washed stone grit plaster on on exterior walls height upto 10 metre above
ground level, in two two layers, under layer 12 12 mm
mm cement plaster
plaster11:4:4 (1
(1
cement
cement:4 : 4 coarse
coarse sand
sand ), furrowing the
), furrowing the under
under layer with scratching
layer with tool,
scratching tool,
applying cement slurry on on the layer@@22 Kg
the under layer Kg of cement perper square
metre, top layer 15 15 mm
mm cement plaster 1:1/ 2:2 (1 cement: 1/2
2:2 (1 1/2coarse
coarse sand
:22 stone
stone chipping
chipping 10
10 mm
mm nominal size), in
nominal size), in panels with groove
panels with groove all
all around
around
per approved pattern, including scrubbing and
as per and washing thethe top
top layer
with brushes and and water to to expose the
the stone chippings ,complete as as per
specification
specification and direction of
and direction of Engineer-in-charge
Engineer-in-charge (payment for providing
(payment forproviding
grooves shall
grooves shall be
be made
made separately).
separately). sqm
sqm 1162.25
13.73 Forming groove ofuniform
of uniform size in the
the top
top layer of washed stone grit plaster
as per approved pattern using wooden battens, nailed to the
as per the under layer,
including removal of of wooden battens, repair to the the edges ofof panels andand
finishing the
finishing the groove
groove complete
complete as as per
per specifications and direction
specifications and direction ofof the
the
Engineer-in-charge::
Engineer-in-charge
13.73.1
13.73.1 15 mm
15 mm wide andand 15 mmmm deep groove metre 75.15
13.73.2 20 mm wide and
20 mm and 15 mmmm deep groove metre 75.80
13.74 Extra for
for washed grit plaster on on exterior walls of height more than 10 m m
from ground level for every additional height of3 of 3 mm or part thereof. sqm
sqm 165.85
13.75 Extra for
for washed stone grit plaster on on circular work notnotexceeding6
exceeding 6 m m in
radius
radius (in two coats).
(in two coats). sqm
sqm 133.55

222
222 SUB HEAD:: 13.0 FINISHING
SUB
Code No Description Unit Rate
13.76 Forming groove of of uniform size from 12x12 mm mm and upto 25x15 mm mm in the the
top
top layer of washed stone grit plastered surface as as per approved pattern,
including
including providing and fixing
providing and fixing aluminum
aluminum channels
channels of of appropriate
appropriate size size and
and
thickness (not
thickness (not less than 2 mm),
less than2 mm), nailed
nailed toto the
the under
under layer with rust
layer with rust proof
proof
screws
screws and and nails
nails and finishing the
and finishing the groove
groove complete
complete as as per
per specifications
specifications
and direction of the
and the Engineer-in-Charge. metre 100.60
13.77 Extra for for using white cement in place of ordinary cement in the the top
top layer of
the
the item of washed stone grit plaster. sqm
sqm 76.05
13.78 Providing
Providing and applying 12
and applying 12 mm thick (average)
mm thick (average) premixed formulated
premixed formulated
one coat gypsum lightweight plaster having additives and
one and light weight
aggregates as vermiculite/ perlite respectively conforming to to IS: 2547 (Part
--1 1& & II)
II) 1976, applied on
1976, applied on hacked
hacked// uneven
uneven background
background such such asas bare
bare brick/
brick/
block/
block/ RCC work on
RCC work on walls&
walls & ceiling
ceiling atat all floors and
all floors and locations, finished in
locations, finished in
smooth line and and level etc. complete. sqm
sqm 468.90
13.79 Extra
Extra for for addition
addition ofof synthetic
synthetic Polyester triangular fibre
Polyester triangular fibre of
of length
length66 mm, mm,
effective diameter 10-40
effective diameter 10-40 microns
microns and specific gravity
and specific gravity ofof 1.34
1.34 to to 1.40
1.40 in in
cement plaster/mortar by by using 125 125 gms. ofsynthetic
of synthetic Polyester triangular per per bag
bag
fibre for
fibre for 50 50 Kgs.
Kgs. cement
cement used used in cement mortar
in cement mortar as as per
per directions
directions of of of
of 50kg of
of
Engineer-in-Charge. cement 78.35
13.80 Providing and and applying white cement based putty of average thickness1 thickness 1
mm, of approved brand and
mm, and manufacturer,
manufacturer, over the the plastered wall surface
to prepare the surface even and smooth complete. sqm
sqm 156.05
13.81
13.81 Distempering
Distempering with with 1st quality acrylic
1st quality acrylic distemper
distemper (ready
(ready mixed)
mixed) having
having VOC VOC
(Volatile
(Volatile Organic
Organic Compound
Compound)) contentcontent less than 50
less than gram/ litre,
50 gram/ of approved
litre, of approved
brand and and manufacturer including applying additional additional coats wherever
required to achieve even shade and colour
13.81.1
13.81.1 Old work (one
Old work (one or or more coats)
more coats) sqm
sqm 62.70
13.82 Wall painting
Wall painting withwith acrylic
acrylic emulsion
emulsion paint,
paint, having
having VOCVOC (Volatile
(Volatile Organic
Organic
Compound
Compound )) content content less than 50
less than grams/ litre,
50 grams/ of approved
litre, of approved brand brand and and
manufacture, including applying additional
manufacture, additional coats wherever required, to
achieve even shade and colour.
13.82.1
13.82.1 One coat
One sqm
sqm 92.00
13.82.2 Two
Two coats sqm
sqm 137.45
13.83 Wall painting with premium acrylic emulsion paint of interior grade, having
VOC (Volatile
VOC (Volatile Organic
Organic Compound
Compound)) content content less than 50
less than 50 grams/
grams/ litre of
litre of
approved brand and manufacture, including applying additional coats
and manufacture,
wherever required to achieve even shade and colour.
13.83.1
13.83.1 One coat
One sqm
sqm 95.45
13.83.2 Two
Two coats sqm
sqm 142.80
13.85 Applying priming coats with primer of of approved brand and and manufacture,
manufacture,
having
having low VOC (Volatile
low VOC (Volatile Organic
Organic Compound
Compound)) content.
content.
13.85.1
13.85.1 With ready mixed pink or grey primer on on wood work (hard and and
soft wood)
soft wood) having
having VOCVOC content
content less than 50
less than grams/ litre
50 grams/ litre sqm
sqm 70.35
13.85.3 With water thinnable cement primer on on wall surface having
VOC content
VOC content less than 50
less than 50 grams/litre
grams/litre sqm
sqm 73.95
13.86 66 mm
mm plaster on
on cement concrete or reinforced cement concrete work with
white cement
white cement based
based polymer
polymer modified self curing
modified self curing mortar of approved make
mortar ofapproved make
as perthedirection
as per the direction of Engineer-In-Charge. sqm
sqm 269.15
13.87 White washing with lime to give anan even shade:
shade :
13.87.1
13.87.1 Old work
Old work (two or more
(two or coats)
more coats) sqm
sqm 22.85

sua HeAD
SUB HEAD:: 13.0
13.0 FiNisHiNG
FINISHING 223
223
Code No Description Unit Rate
13.87.2 Old work (one
Old work (one or
or more coats)
more coats) sqm
sqm 13.90
13.88 Removing white or colour wash by by scrapping and
and sand papering and and
preparing the surface smooth including necessary repairs to scratches etc.
complete sqm
sqm 19.75
13.91
13.91 Removing
Removing dry or oil
dry or oil bound distemper, water
bound distemper, water proofing cement paint
proofing cement and
paint and
the by scrapping, sand papering and
the like by and preparing the surface smooth
including necessary repairs to scratches etc. complete. sqm
sqm 25.15
13.92 Painting on
on G.S. sheet with synthetic enamel paint of approved brand and
and
manufacture ofof required colour to give an
an even shade:
shade : sqm
sqm
13.92.1
13.92.1 Old work (one
Old work (one or
or more coats)
more coats) sqm
sqm 93.30
13.93 Painting
Painting (two or more
(two or coats) on
more coats) on rain water, soil,
rain water, waste and
soil, waste and vent
vent pipes
pipes
and fittings with
and fittings with black anticorrosive bitumastic
black anticorrosive bitumastic paint of approved
paint of approved brand
brand
and manufacture over and
and includingaa priming coat of
and including of ready mixed zinc
chromate yellow primer onon new
new work:
work :
13.93.1
13.93.1 75 mm
75 mm diameter pipes metre 57.25
13.94 Painting
Painting (one
(one or
or more
more coats) on rain
coats) on water, soil
rain water, waste and
soil waste and vent
vent pipes and
pipes and
fittings with
fittings with black
black anticorrosive
anticorrosive bitumastic
bitumastic paint of approved
paint of approved brand and
brand and
manufacture on on old
oldwork:
work :
13.94.1
13.94.1 75 mm
75 mm diameter pipes metre 26.85
13.94.2 100 mm
100 mm diameter pipes metre 35.50
13.94.3 150 mm
150 mm diameter pipes metre 51.20
13.95 Painting
Painting (two
(two or
or more
more coats) on rain
coats) on water, soil
rain water, waste and
soil waste vent pipes
and vent pipes and
and
fittings with
fittings with aluminium
aluminium paint of approved
paint of approved brand
brand and
and manufacture over a
manufacture overa
priming coat ofof ready mixed zinc chromate yellow primer on new work:
on new work :
13.95.1
13.95.1 75 mm
75 mm diameter pipes metre 58.90
13.95.2 100 mm
100 mm diameter pipes metre 81.45
13.95.3 150 mm
150 mm diameter pipes metre 121.35
13.96 Painting
Painting (one or more
(one or more coats) on rain
coats) on water, soil
rain water, soil waste
waste and vent pipes
and vent pipes and
and
fittings with
fittings with synthetic
synthetic enamel
enamel paint of approved
paint of approved brand and manufacture
brand and manufacture
and required colour on
and on old work:
work :
13.96.1
13.96.1 75 mm diameter pipes
75 mm metre 28.20
13.96.2 100 mm
100 mm diameter pipes metre 36.25
13.96.3 150 mm
150 mm diameter pipes metre 52.25
13.97 Painting with oil type wood preservative ofapproved
of approved brand and manufacture:
and manufacture:
13.97.1
13.97.1 Old work
Old work (one or more
(one or more coats)
coats) sqm
sqm 41.20
13.99 Painting with synthetic enamel paint of approved brand and and manufacture
of
of required colour to give an
an even shade
shade::
13.99.1
13.99.1 One or more coats on
One on old
old work sqm
sqm 102.80
13.100 Painting with aluminium paint of approved brand and and manufacture to
to give
an
an even shade:
13.100.1
13.100.1 One or more coats on
One on old work sqm
sqm 96.00
13.101
13.101 Painting with acid proof paint of approved brand and and manufacture ofof
required colour to give anan even shade
shade::
13.101.1
13.101.1 One or more coats on
One on old work sqm
sqm 107.25

224
224 SUB HEAD:: 13.0 FINISHING
SUB
Code No Description Unit Rate
13.102 Painting with black anti-corrosive bitumastic paint of approved brand and
and
manufacture to
to give an
an even shade:
shade :
13.102.1
13.102.1 One or more coats on
One on old work sqm
sqm 93.70
13.103 French spirit polishing
polishing::
13.103.1
13.103.1 One or more coats on
One on old work sqm
sqm 224.80
13.104 Polishing on
on wood work with ready made wax polish of approved brand
and manufacture
and manufacture::
13.104.1
13.104.1 Old work
Old sqm
sqm 99.80
13.105 Re-lettering with black Japan paint of approved brand and
and manufacture. per letter
per cm
per cm
height 3.85
13.106 Painting
Painting (one
(one or
or more
more coats) with black
coats) with Japan paint
black Japan paint of approved brand
of approved and
brand and
manufacture to
to give an
an even shade. sqm
sqm 95.80
13.107 Providing and fixing
Providing and fixing C.P.
C.P. brass chain and
brass chain and rubber
rubber plug complete forsink
plug complete for sink or
or
wash basin:
13.107.1
13.107.1 32 mm
32 mm dia each 80.10
13.107.2 40 mm dia
40 mm each 78.65
13.109 Finishing walls with
Finishing walls with water
water proofing cement paint
proofing cement paint of
of required
required shade
shade::
13.109.1
13.109.1 Old work (one
Old work (one or
or more coats applied@
more coats applied @ 2.20
2.20 kg/10
kg/10 sqm) over
sqm) over
priming coat ofof primer applied
applied@@ 0.80 litrs/10
Iitrs/10 sqm
sqm complete
including cost of Priming coat. sqm
sqm 112.90
13.109.2 Old work (one
Old work or more
(one or more coats
coats@@ 2.20
2.20 kg/10
kg/10 sqm)
sqm) complete.
complete. sqm
sqm 75.80
13.110 Finishing walls with textured exterior paint of required shade:
shade :
13.110.1
13.110.1 Old work (Two or
Old ormore
more coats onon existing cement paint surface
applied@
applied @ 3.28 ltr/10
Itr/10 sqm. sqm
sqm 169.20
13.110.2 Old work (One
Old work or more coats)
(One ormore applied @ 1.82
coats) applied@ 1.82 ltr/10 sqm.
Itr/10 sqm. sqm
sqm 109.10
13.111
13.111 Finishing walls with Acrylic Smooth exterior paint of required shadeshade::
13.111.1
13.111.1 Old work (Two or more coat applied @ 1.67 ltr/ 10
Old work (Two or more coat applied@ 1.67 Itr/ 10 sqm)
sqm) on
on
existing cement paint surface sqm
sqm 120.75
13.111.2 Old work
Old work (One or more coat
(One ormore applied @ 0.90
coat applied@ 0.90 ltr/10 sqm).
Itr/10 sqm). sqm
sqm 80.65
13.112 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone
additives of required shade
13.112.1
13.112.1 Old work
Old work (Two or more coats
(Two ormore applied @ 1.43
coats applied@ 1.43 ltr/
Itr/ 10 sqm) over
10 sqm) over
existing cement paint surface sqm
sqm 131.30
13.112.2 Old work
Old work (one
(one oror more
more coats applied @ 0.83
coats applied@ 0.83 ltr/10 sqm).
Itr/10 sqm). sqm
sqm 88.55
13.113 Varnishing with
Varnishing with varnish
varnish ofof approved
approved brand
brand and
and manufacture:
manufacture:
13.113.1
13.113.1 One or more coats with copal varnish
One sqm
sqm 94.60
13.113.2 One or more coats with spar varnish
One sqm
sqm 95.05
13.114 Melamine
Melamine polishing
polishing onon wood
wood work
work (one or more
(one or more coat).
coat). sqm
sqm 1192.30
13.115 Varnishing with
Varnishing with flatting
flatting varnish
varnish of
of approved
approved brand and manufacture
brand and one or
manufacture one or
more coats on
on old work. sqm
sqm 99.70

sua HeAD
SUB HEAD:: 13.0
13.0 FiNisHiNG
FINISHING 225
225
Code No Description Unit Rate
13.116 Polishing
Polishing in
in high gloss/matt finish
high gloss/matt finish melamine
melamine clear clear polish
polish onon wood
wood work
work
in required color/wooden shade texture with following process in the the
sequence as detailed below:
1. The
The surface to be be polished is rubbed with sand paper 80/120 no. no. and
and
then with sand paper of of 160/180 nos.
2. Applying two
2. Applying two coats
coats of of sealer
sealer withwith spray
spray gun gun and
and allowing sufficient
allowing sufficient
drying time for 1st coat and
for 1st and 2nd
2nd coat is allowed to dry for for88 to 12 hrs.
3. On
3. drying of
On drying sealer coat,
of sealer coat, wet
wet rubbing
rubbing with with emery
emery cloth
cloth of
of finer
finer grading
grading
with ample water to to remove excess sealer layer and and make thesurface
the surface
further smooth after this wet rubbing, then surface is applied with
wet rubbing,
special grade melamine
special grade fillers to
melamine fillers to fill
fill all
all the
the small
small and
and big
big holes/grooves
holes/grooves
etc. Filler coat to be
be allowed to dry for for44 to66 hrs on on which againagainaa light
wet
wet rubbing is done this surface is further allowed to dry for for 12 hrs.
4. On
On this, 1st
1st coat ofof melamine polish is applied with spray gun gun using
melamine clear polish and and melamine thinner in required proportion.
This 1st
1st coat is allowed to dry for24 for 24 hrs then this dry dry surface is again
fine wet
fine wet rubbed
rubbed smooth, which is
smooth, which further allowed
is further allowed to to dry
dry for12
for 12 hrs. The
hrs. The
final melamine
final melamine polish
polish isis applied
applied withwith compressor
compressor pressure spray gun
pressure spray gun
using melamine clear polish and and melamine thinner mixed in required
proportion complete as per per direction of Engineer-in-Charge. (Final
coat to be
coat to done in
be done in11 or2
or 2 layers without gap
layers without gap ofof time.)
time.) sqm
sqm 3049.85

226 SUB HEAD:: 13.0 FINISHING


SUB
SUB HEAD
SUB HEAD:: 14.0
REPAIRS TO
TO BUILDING
14.0 REPAIRS TO
TO BUILDING

Code No Description Unit Rate


14.1
14.1 Repairs to plaster of thickness 12
12 mm
mm to 2020 mm
mm in patches ofof area 2.5
2.5
sq.meters and
and under, including cutting the
the patch in proper shape, raking
out joints and
and preparing and
and plastering the
the surface of the walls complete,
including disposal of rubbish to the dumping ground, all complete as per
direction of Engineer-in-Charge.
14.1.1
14.1.1 With cement
With cement mortar
mortar 1:4
1:4 (1 cement : 4 fine
(1 cement:4 fine sand)
sand) sqm
sqm 547.40
14.1.2 With cement
With cement mortar
mortar 1:4
1:4 (1cement:
(1cement:44 coarse
coarse sand)
sand) sqm
sqm 560.50
14.2 Fixing chowkhats in existing opening including embedding chowkhats
in floors or
in floors or walls
walls cutting
cutting masonry for holdfasts, embedding
masonry forholdfasts, embedding hold fasts in
hold fasts in
cement concrete blocks of size 15 15xx 10
10xx 10
10 cm
cm with cement concrete1 :3:6
concrete 1:3:6
(1
(1 cement
cement:3 : 3 coarse
coarse sand : 6 graded
sand:6 graded stone
stone aggregate
aggregate 20 20 mm
mm nominal size),
nominal size),
painting two
two coats ofof approved wood preservative to sides of chowkhats
and making
and good thedamages
making good the damages towalls
to walls and floors as
and floors as required complete,
required complete,
including disposal of rubbish to the dumping ground, all complete as per
direction of Engineer-in-Charge.
14.2.1
14.2.1 Door chowkhats each 1782.55
14.2.2 Window chowkhats each 1125.15
14.2.3 Clerestory window chowkhats each 851.00
14.3 Fixing chowkhat in existing opening in brick/ RCCRCC wall with dash fasteners/
Chemical fasteners of appropriate size (3 nos nos on
on each vertical member of of
door chowkhat
door chowkhat and2
and 2 nos
nos onon each vertical member
each vertical member of window chowkhats),
ofwindow chowkhats),
including Cost ofofdash
dash fasteners/ chemical fastener. each 217.10
14.4 Making the opening in
Making theopening in brick
brick masonry
masonry including
including dismantling
dismantling in floor or
in floor walls
or walls
by cutting masonry
by cutting and making
masonry and good thedamages
making good the damages towalls,
to walls, flooring
flooring and
and
jambs complete, to match existing surface including disposal of mulba/
rubbish to the nearest municipal dumping ground, all complete as per per
direction of Engineer-in-Charge.
14.4.1
14.4.1 For door/ window/ clerestory window
For sqm
sqm 1264.35
14.5 Renewing glass panes, with putty and and nails wherever necessary including
racking out the old putty:
14.5.1
14.5.1 Float glass panes ofnominal
of nominal thickness4 mm (weight not less
thickness 4 mm
than 10kg/sqm)
than 10kg/sqm) sqm
sqm 1090.65
14.5.2 Float glass panes of
ofnominal
nominal thickness5 mm (weight not less
thickness 5 mm
than 12.5kg/sqm)
than 12.5kg/sqm) sqm
sqm 1416.15
14.6 Renewing glass panes,
Renewing glass with wooden
panes, with wooden fillets
fillets wherever
wherever necessary:
necessary:
14.6.1
14.6.1 Float glass panes of
ofnominal
nominal thickness4 mm (weight not less
thickness 4 mm
than 10kg/sqm)
than 10kg/sqm) sqm
sqm 1580.90
14.6.2 Float glass panes of
ofnominal
nominal thickness5 mm (weight not less
thickness 5 mm
than 12.5kg/sqm)
than 12.5kg/sqm) sqm
sqm 1906.40
14.7 Renewing glass panes
Renewing glass panes and
and refixing existing wooden
refixing existing wooden fillets:
fillets:
14.7.1
14.7.1 Float glass panes of ofnominal
nominal thickness4 mm (weight not less
thickness 4 mm
than 10kg/sqm)
than 10kg/sqm) sqm
sqm 1227.30
14.7.2 Float glass panes ofnominal
of nominal thickness5 mm (weight not less
thickness 5 mm
than 12.5kg/sqm)
than 12.5kg/sqm) sqm
sqm 1552.75
14.8 Supplying and fixing
Supplying and fixing new wooden fillets
new wooden fillets wherever
wherever necessary:
necessary:
14.8.1
14.8.1 2nd class
2nd class teak
teak wood
wood fillets
fillets metre 77.70
14.8.2 Hollock wood fillets
Hollock wood fillets metre 70.75

sua HeAD
SUB HEAD:: 14.0
14.0 RePAiRs ro auiLDiNG
REPAIRS TO BUILDING 229
229
Code No Description Unit Rate
14.9 Renewal of old putty of
Renewal ofoldputty of glass
glass panes
panes (length)
(length) metre 56.15
14.10 Refixing old glass
Refixing old glass panes with putty
panes with and nails
putty and nails sqm
sqm 729.85
14.11
14.11 Fixing old glass
Fixing old glass panes with wooden
panes with wooden fillets
fillets (excluding cost of
(excluding cost fillets)
of fillets) sqm
sqm 679.60
14.12 Providing
Providing and fixing 16
and fixing 16 mm
mm M.S.M.S. Fan clamps of
Fan clamps of standard shape and
standard shape and
size in existing R.C.C. slab, including cutting chase, anchoring clamp to to
reinforcement
reinforcement bar, bar, including
including cleaning,
cleaning, refilling,
refilling, making
making good
good the the chase
chase
with matching concrete,
concrete, plastering and and painting the the exposed portion of the the
clamps complete. each 563.90
14.13 Regrading terracing of mud mud phaska covered with tiles or or brick,
brick, in cement
mortar by dismantling tiles or or bricks, removing mud mud plaster, preparing
the surface of mud mud phaska to to proper slope, relaying mud mud plaster gobri
leaping and tiles
leaping and tiles or
or bricks, grouted in
bricks, grouted in cement
cement mortar
mortar 1:3
1:3 (1 cement : 3 fine
(1 cement:3 fine
sand), including
sand), including replacing
replacing unserviceable tiles or
unserviceable tiles or bricks with new
bricks with new ones and
ones and
disposal of unserviceable material to the the dumping ground (the cost of the
new tiles or
new tiles or brick excluded), all
brick excluded), complete as
all complete as per direction of
per direction of Engineer-in-
Engineer-in-
Charge. sqm
sqm 696.05
14.14 Replacing sand stone
Replacing sand slabs in
stone slabs in roofing,
roofing, laid
laid in
in cement
cement mortar
mortar11:4 :4 (1
(1 cement
cement
:44 coarse
coarse sand),
sand), including
including necessary
necessary repairs
repairs andand cement
cement pointing with
pointing with
same mortar complete, including disposal of rubbish to dumping ground,
all complete as per direction of Engineer-in-Charge.
14.14.1
14.14.1 Red/ white sand stone slabs 30 30 to 5050 mm
mm thick sqm
sqm 1365.85
14.15 Renewing wooden battens in roofs, including making good the the holes
in wall and
and painting with oil type wood preservative of approved brand
and
and manufacture complete, including removal of of rubbish to the dumping
ground, all complete as per direction of Engineer-in-Charge.
14.15.1
14.15.1 Sal wood battens
Sal cum
cum 99120.65
14.16 Renewing wooden beams in roofs including making good the the holes in
walls and
and painting with oil type wood preservative of approved brand
and
and manufacture complete, including removal of of rubbish to the dumping
ground, all complete as per per direction
direction of Engineer-in-Charge.
14.16.1
14.16.1 Not exceeding 4.00 metres in length.
Not
14.16.1.1
14.16.1.1 Sal wood beams
Sal cum
cum 104573.95
14.16.1.2 Hollock wood beams cum
cum 70271.70
14.16.2 Above 4.00 metres and and upto 5.00 metres length.
14.16.2.1
14.16.2.1 Sat wood beams
Sal cum
cum 107320.00
14.16.2.2 Hollock wood beams cum
cum 72987.25
14.17 Raking out
out joints in lime or cement mortar andand preparing the surface for for
re-pointing or replastering,
re-pointing replastering, including disposal of rubbish to the dumping
ground, all complete as per direction of Engineer-in-Charge. sqm
sqm 72.45
14.18 Flush
Flush pointing with cement
pointing with cement mortar
mortar 1:3
1:3 (1 cement :3 3 fine
(1 cement: fine sand)
sand) mixed with
mixed with
2% of
2% of integral water proofing
integral water compound by
proofing compound weight of
by weight of cement
cement forflat
for flat tile
tile
bricks on
on top
top of mud
mud phaska
phaska::
14.18.1
14.18.1 With F.P.S. brick tiles sqm
sqm 137.70
14.18.2 With modular brick tiles sqm
sqm 139.05
14.19 Taking out wind ties from roof including cutting out out rusted bolts, nuts etc.
and removing materials to any
and any distance within compound and stacking. kg 5.40
14.20 Fixing
Fixing of old wind
of old wind tie
tie with
with new fittings including
new fittings including painting two or
painting two or more
more coats
coats
with anticorrosive bitumastic paint of approved brand
brand&& manufacturer over
and including priming coat of
and of ready mixed zinc chromate yellow primer of of
approved brand. metre 126.00

230
230 SUB HEAD:: 14.0 REPAIRS TO BUILDING
SUB
Code No Description Unit Rate
14.21
14.21 Renewing bottom rail and/or top runner of of collapsible gate including
making good all damages and applying priming coat of of zinc chromate
yellow primer of
of approved brand and manufacturer.
and manufacturer. kg 298.85
14.22 Renewing Wrought iron or or M.S. Wheel or
or roller of
of steel door or
or gate and
and
fitting and
fitting fixing the
and fixing the same with necessary
same with necessary clamps,
clamps, nuts and bolts/welding
nuts and bolts/welding
and
and erection etc. complete.
14.22.1
14.22.1 Wheel 50 mm mm dia
diaand
and below per wheel
per 123.70
14.22.2 Wheel above 50 mm mm dia
dia per wheel 304.55
EARTH WORK
14.23 Pumping outwater
out water caused by springs, tidal or or river seepage, broken water
mains or and the like.
or drains and kilo litre 231.05
BRICK WORK
14.25 Brick work with common burnt clay bricks of class designation 7.5 in mud mud
mortar cum
cum 6207.25
WOOD WORK
14.26 Providing and fixing
Providing and fixing 25
25 mm thick shutters
mm thick for cup
shutters for cup board
board etc.
etc.::
14.26.1
14.26.1 panelled&& glazed shutters
Panelled or panelled shutters::
14.26.1.1
14.26.1.1 Superior class teak wood including nickel plated
bright finished M.S.
bright finished M.S. piano
piano hinges with necessary
hinges with necessary
screws. sqm
sqm 5127.00
14.26.1.2 Ist class teak wood including nickel plated bright
finished M.S.
finished M.S. piano
piano hinges with necessary
hinges with necessary
screws. sqm
sqm 4484.85
14.26.2 Glazed shutters:
shutters :
14.26.2.1
14.26.2.1 Superior class teak wood including nickel plated
bright finished M.S.
bright finished M.S. piano
piano hinges with necessary
hinges with necessary
screws. sqm
sqm 5054.05
14.26.2.2 Ist class teak wood including nickel plated bright
finished M.S.
finished M.S. piano
piano hinges with necessary
hinges with necessary
screws. sqm
sqm 4362.45
14.27 Providing and fixing
Providing and fixing plain jaffri door
plain jaffri door and
and window
window shutters
shutters including
including bright
bright
or/and black enamelled M.S. butt hinges with necessary screws 35x10
mm
mm laths
laths placed
placed 3535 mm apart (frames
mm apart to be
(frames to be paid
paid separately),
separately), including
including
fixing 50x12
fixing 50x12 mmmm beading
beading complete with :
complete with:
14.27.1
14.27.1 Second class teak wood sqm
sqm 4602.65
14.28 Providing and fixing
Providing and fixing brass
brass curtain
curtain rods
rods of wall thickness
of wall thickness 1.25
1.25 mm with two
mm with two
brass
brass brackets fixed with
brackets fixed with brass screws and
brass screws and wooden
wooden plugs
plugs etc. wherever
etc. wherever
necessary complete.
14.28.1
14.28.1 20 mm diameter.
20 mm diameter. metre 343.50
14.28.2 25 mm diameter.
25 mm diameter. metre 421.75
14.29 Providing and fixing
Providing and fixing M.S.
M.S. round
round or
or square
square bars with M.S.
bars with flats at
M.S. flats at required
required
spacing in wooden frames ofwindows
of windows and clerestory windows. kg 120.75
14.30 Providing joists (karries)
Providing joists (karries) including
including hoisting, fixing in
hoisting, fixing in position
position and
and applying
applying
wood preservative on on unexposed surface etc. complete with: with :
14.30.1
14.30.1 Sal wood
Sal cum
cum 97978.30
14.30.2 Hollock wood cum
cum 64022.85
14.31
14.31 Providing and fixing
Providing and fixing bright finished brass
bright finished brass single
single acting spring hinges
acting spring with
hinges with
necessary brass screws etc. complete
complete::

sua HeAD
SUB HEAD:: 14.0
14.0 RePAiRs ro auiLDiNG
REPAIRS TO BUILDING 231
Code No Description Unit Rate
14.31.1
14.31.1 150 mm
150 mm each 765.05
14.31.2 125 mm
125 mm each 546.00
14.31.3 100 mm
100 mm each 485.65
14.32 Providing
Providing and fixing bright
and fixing finished brass
bright finished brass double acting spring
double acting spring hinges with
hinges with
necessary brass screws etc. complete:
complete :
14.32.1
14.32.1 150 mm
150 mm each 851.85
14.32.2 125 mm
125 mm each 726.65
14.32.3 100 mm
100 mm each 704.75
14.33 Providing and fixing
Providing and fixing bright finished brass
bright finished flush bolts
brass flush with necessary
bolts with necessary brass
brass
screws etc. complete:
complete :
14.33.1
14.33.1 250 mm
250 mm each 285.05
14.33.2 150 mm
150 mm each 245.35
14.33.3 100 mm
100 mm each 188.45
14.34 Providing
Providing and fixing 150
and fixing 150 mm
mm bright finished floor
bright finished floor brass door stopper
brass door with
stopper with
rubber cushion, necessary brass screws etc. to suit shutter thickness
complete each 271.45
14.35 Providing and fixing
Providing and fixing bright finished brass
bright finished brass hard
hard drawn
drawn hooks and eyes:
hooks and eyes :
14.35.1
14.35.1 300 mm
300 mm each 101.85
14.35.2 250 mm
250 mm each 97.70
14.35.3 200 mm
200 mm each 87.75
14.35.4 150 mm
150 mm each 70.55
14.35.5 100 mm
100 mm each 61.85
14.36 Providing
Providing and fixing bright
and fixing finished brass
bright finished fan light
brass fan light pivot with necessary
pivot with necessary
brass screws etc. complete. each 47.30
14.37 Providing
Providing and fixing 300
and fixing 300 mm
mm long
long bright finished brass
bright finished brass chain with hook
chain with for
hook for
fanlight
fan light including necessary brass screws etc. complete. each 74.80
14.38 Providing and fixing
Providing and fixing bright finished brass
bright finished quadrant stay
brass quadrant stay 300
300 mm
mm long with
long with
necessary brass screws etc. complete. each 191.45
14.39 Providing
Providing and fixing bright
and fixing finished brass
bright finished brass helical door spring
helical door spring (superior
(superior
quality).
quality). each 543.95
14.40 Providing
Providing and fixing chromium
and fixing chromium plated
plated brass
brass butt
butt hinges with necessary
hinges with necessary
chromium plated brass screws etc. complete.
14.40.1
14.40.1 125x70x4
125x70x4 mm mm (ordinary type)
(ordinary type) each 171.05
14.40.2 100x70x4
100x70x4 mm
mm (ordinary type)
(ordinary type) each 148.75
14.40.3 75x65x4 mm
75x65x4 mm (heavy type)
(heavy type) each 181.00
14.40.4 75x40x2.5 mm
75x40x2.5 mm (ordinary type)
(ordinary type) each 102.60
14.40.5 50x40x2.5 mm
50x40x2.5 mm (ordinary type)
(ordinary type) each 47.60
14.41
14.41 Providing and fixing
Providing and fixing 85x42
85x42 mm chromium plated
mm chromium plated brass
brass pull
pull bolt
bolt lock with
lock with
necessary chromium plated brass screws, nuts, bolts and and washers etc.
complete. each 278.60
FINISHING

232
232 SUB HEAD:: 14.0 REPAIRS TO BUILDING
SUB
Code No Description Unit Rate
14.72 Providing
Providing and and fixing
fixing double
double scaffolding
scaffolding system
system (cup (cup lock type) on
lock type) on the
the
exterior side, up up to seven story height made with 40 40 mmmm dia M.S. tube
1.5 m
1.5 m centre to centre, horizontal
horizontal&& vertical tubes joining with cup cup&& lock
system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase
system in
system the scaffolding
in the scaffolding for for working
working platform
platform etc. and maintaining
etc. and maintaining itit in ina a
serviceable condition for for the required duration as as approved and and removing
itit there
there after. The scaffolding
after. The scaffolding system
system shallshall bebe stiffened
stiffened withwith bracings,
bracings,
runners, connection with the the building etc wherever required for for inspection
of work atrequired
at required locations with essential safety features forthe for the workmen
etc. complete as per directions and and approval of Engineer-in-charge. The The
elevational area
elevational of the scaffolding
area ofthe scaffolding shall
shall bebe measured for payment purpose.
measured forpayment purpose.
The payment
The payment will will be
be made
made onceonce irrespective
irrespective of of duration
duration of of scaffolding.
scaffolding. sqm
sqm 338.25
Note: - This item to be be used formaintenance
for maintenance work judicially,judicially, necessary
deduction for scaffolding in
deduction forscaffolding the existing
in the existing item to be
item to be done.
done.
14.73 Providing
Providing and and fixing
fixing bright finished brass
bright finished brass casement
casement windowwindow fasteners
fasteners or or
peg stays to windows/ ventilators with necessary welding and
peg and machine
screws etc. complete. kg 557.20
14.74 Providing
Providing and and fixing
fixing 1414 mm
mm bright finished brass
bright finished brass spring
spring catch
catch to to steel
steel centre
centre
hung ventilators with necessary welding and and machine screws etc. complete. each 68.35
14.75 Repair to to plaster of thickness 12 12 mmmm to 20 20 mmmm in patches of of area 2.5
sqm
sqm and and under, including cutting the the patch in proper shape, raking out
joints andand preparing plastering the the wall surface with white cement based
polymer
polymer modified
modified self self curing
curing mortar,
mortar, including disposal of
including disposal of rubbish,
rubbish, allall
complete as per per the direction of Engineer-In-Charge. sqm
sqm 670.95
ROUTINE
ROUTINE MAINTENANCE
MAINTENANCE WORK WORK
14.75A Cleaning
Cleaning of of terrace/loft
terrace/loft water
water storage
storage tanktank (inside surface area)
(inside surface area) upto 2000
upto 2000
litre capacity at all heights with coconut brushes, duster etc., removal ofsilt, of silt,
rubbish from the tank and and cleaning the tank with fresh water disinfecting
with bleaching powder@@ 0.5gm per perlitre
litre capacity of tank including marking
the date of of cleaning on on the side of tank body with the help of stencil and and
paint and and disposing of malba all complete as per direction of Engineer-
in-Charge. (The old old date already written on on tank should be be removed with
paint remover or or black paint and and if date is notnot written with the stencil or old old
date is
date is not
not removed deduction will
removed deduction will be
be made
made@@ Rs. 0.10 per
Rs.0.10 per litre)
litre) (if during
(if during
cleaning any
cleaning any GI fittings or
GI fittings or ball cock is
ball cock damaged that
is damaged that is to be
is to be repaired
repaired by by
contractor at
contractor at his
his own cost and
own cost and nothing
nothing extra will be
extra will be paid
paid onon this
this account)
account) litre 0.50
14.76 Cleaning and and desilting of gully trap chamber, including removal of of rubbish
mixed with earth etc. and and disposal of same, all as as per
per thethe direction of
Engineer-in-charge. each 108.30
14.77 Cleaning of of chocked sewer line by by diesel running vehicle mounting
hydraulic operated high pressure suction cum cum jetting sewer cleaning
machine
machine fitted fitted with
with pump
pump having 4000 litres
having 4000 suction capacity
litres suction capacity and and 6000
6000
litres water jetting tank capacity including skilled operator, supervising
engineer etc. for cleaning and and partial desilting of manholes and dechocking
of sewer
of sewer lines.
lines. Dechocking
Dechocking and and flushing
flushing of of sewer
sewer line from one
line from one manhole
manhole
toanother
to another by high pressure jetting system of of2200
2200 PSIPSIforfor sewer line from
150 mm mm diadia upto 300 300 mm mm metre 340.75

sua HeAD
SUB HEAD:: 14.0
14.0 RePAiRs ro auiLDiNG
REPAIRS TO BUILDING 233
Code No Description Unit Rate
14.78 Cleaning of
of under ground sump, Over Head R.C.C. Tank(Tank ( independent
staging) including
staging) disposal of
including disposal of slit and rubbish,
slit and all as
rubbish, all as per
per direction of
direction of
Engineer-in-Charge. The
The cleaning shall consist following operations:-
(i)Tank
(i)Tank shall
shall be emptied ofwater
be emptied of water by
by pumping
pumping&& bottom shall be
bottom shall be cleaned of
cleaned of
silt and
and other deposits.
(ii)
(ii) Entire
Entire surface area of
surface area the sump
of the sump shall then scrubbed
shall then scrubbed thoroughly
thoroughly with
with
wire brush etc. andand pressure washed with water.
(iii)
(iii) Chlorination
Chlorination of
of RCC
RCC internal surface by
internal surface by liquid
liquid chlorine.
chlorine.
(iv) The treated
(iv) The treated surface
surface shall
shall be dried using
be dried using air jetting and
airjetting and all
all loose
loose particles
particles
shall bebe removal from the surface.
(v)
(v) Finally the surface
Finally the surface shall
shall be treated with
be treated with ultraviolet
ultraviolet radiation etc. as
radiation etc. as per
per
direction of Engineer-in-Charge. sqm
sqm 422.70
14.79 Disconnecting
Disconnecting damaged
damaged overhead/terrace
overhead/terrace PVC water storage
PVC water tank of
storage tank of
any
any size from water supply line andand removing from the terrace including
shifting at ground level as per direction of Engineer-in-charge.
as per each 433.75
14.80 Providing
Providing&& fixing
fixing White
White vitreous
vitreous china
china water
water closet
closet squatting
squatting pan
pan (Indian
(Indian
type) along
type) along with
with “S”“S” or “P” trap
or “P” trap including
including dismantling of old
dismantling of old WC
WC seat and
seat and
“S” or
“S” or “P” trap at
“P” trap at site
site complete
complete with with all
all operations
operations including all necessary
including all necessary
materials, labour and
materials, and disposal of dismantled material including malba, all
complete as per per the
the direction
direction of Engineer-in charge.
14.80.1
14.80.1 Long pattern W.C W.C PanPan of size 580x440 mm mm each 3501.70
14.80.2 Orissa pattern W.C Pan of size 580x440 mm
W.C Pan mm each 4478.75
14.81
14.81 Cutting
Cutting holes
holes of of required
required size
size inin brick
brick masonry wall for
masonry wall for fixing
fixing of
of exhaust
exhaust fan
fan
including
including providing
providing and fixing 300
and fixing 300 mmmm dia
dia PVC
PVC pipe conforming BIS-12818
pipe conforming BIS-12818
and
and making good thesamethe same etc. complete as per direction of Engineer-in-
charge. each 288.10
14.82 Dismantling W.C. Pan
Dismantling Pan of
ofall
all sizes including disposal of dismantled materials
including malba all complete as per directions of Engineer-in-Charge. each 134.10
14.83 Hacking
Hacking of of CC flooring including
CC flooring including cleaning for surface etc.
cleaning forsurface etc. complete
complete as as per
per
direction of thethe Engineer-in-Charge. sqm
sqm 3.45
14.84 Dismantling 15 15 to 40 40 mmmm dia G.I. pipe including stacking of dismantled
pipes
pipes (within
(within 50
50 metres
metres lead)
lead) asas per direction of
per direction of Engineer-in-Charge.
Engineer-in-Charge.
(a)
(a) Internal Work- Exposed
Internal Work- Exposed on on wall
wall metre 3.25
14.85 Taking out existing wooden door shutter, shutter, repair by by cutting, painting etc.
and refixing
and of repaired
refixing of repaired doordoor shutters
shutters to to existing
existing door frames, including
door frames, including
replacement of of hinges with screws, etc. as as required, all complete as per per
the direction of the the Engineer-in-charge. each 429.10
14.86 Providing
Providing and and laying
laying in in situ
situ seven
seven course water proofing
course water treatment with
proofing treatment with
APP (Atactic
APP (Atactic poly-propylene)
poly-propylene) modified
modified Polymeric
Polymeric memberane
memberane over over roof
roof
consisting of
consisting of first
first coat
coat ofof bitumen
bitumen primer
primer@@ 0.400.40 litre
litre per sqm, 2nd,
per sqm, 2nd, 4th
4th
&& 6th courses of material@@ 1.20 Kg/sqm, which shall consist of
of bonding material
blown type bitumen of of grade 85/25 conforming to IS:: 702, 3rd and
to IS Sth
and 5th
layers
layers of of roofing
roofing membrane
membrane APP APP modified
modified Polymeric
Polymeric membrane
membrane 1.5 mm
1.5mm
thick of
thick of 2.25
2.25 Kg/sqm weight consisting
Kg/sqm weight consisting of five layers
of five layers prefabricated
prefabricated withwith
centre core
centre core asas 20
20 micron
micron HMHDPE
HMHDPE film film sandwiched
sandwiched on on both
both sides with
sides with
polymeric mix mix and
and the polymeric mix mix is protected on on both side with 20 20
micron
micron HMHDPE
HMHDPE film. film. 7th, the top
7th, the top most
most layer shall be
layer shall finished with
be finished with brick
brick
tiles of
of class designation 10 10 grouted with cement mortar 1:3 1:3 (1cement
(1cement::3 3
fine sand)
fine sand) mixed with 2%
mixed with 2% integral water proofing
integral water compound by
proofing compound weight of
by weight of
cement overa
cement over a 1212 mmmm layer
layer ofof cement
cement mortar
mortar 1:3
1:3 (1
(1 cement
cement::3 3 fine
fine sand)
sand)
and finished
and finished neat
neat (item
(item ofof laying
laying brick tiles shall
brick tiles shall be
be paid for separately).
paid forseparately). sqm
sqm 730.55

234
234 SUB HEAD:: 14.0 REPAIRS TO BUILDING
SUB
Code No Description Unit Rate
14.87 Providing
Providing and and laying
laying in in situ five course
situ five water proofing
course water treatment with
proofing treatment with
APP (Atactic
APP (Atactic Polypropylene)
Polypropylene) modified modified Polymeric
Polymeric memberane
memberane over over roof
roof
consisting of
consisting first coat
of first coat of of bitumen
bitumen primer primer@@ 0.400.40 litre
litre per sqm, 2nd&
per sqm, 2nd & 4th4th
courses of of bonding materialmaterial@@ 1.20 kg/sqm, which shall consist of blown
type bitumen
type bitumen of grade 85/25
of grade 85/25 conforming
conforming to to IS
IS:: 702,
702, 3rd 3rd layer
layer of of roofing
roofing
membrane
membrane APP APP modified
modified Polymeric
Polymeric membranemembrane 2.0 2.0mm mm thick thick ofof 3.00
3.00 Kg/
Kg/
sqm weight
sqm weight consisting
consisting of of five
five layers
layers prefabricated
prefabricated with with centre
centre corecore asas 100
100
micron
micron HMHDPE
HMHDPE film film sandwiched
sandwiched on on both sides with
both sides with polymeric
polymeric mix and
mix and
the polymeric
the polymeric mix mix is is protected
protected on on both side with
both side with 20
20 micron
micron HMHDPEHMHDPE film. film.
5th, the
Sth, the top
top most
most layer shall be
layer shall finished with
be finished with brick tiles of
brick tiles class designation
of class designation
10 grouted with
10 grouted with cement
cement mortarmortar 1:3 1:3 (1(1 cement
cement:3: 3 fine
fine sand)
sand) mixed
mixed withwith 2%
2%
integral water proofing
integral water proofing compound
compound by weight of
byweight of cement
cement over overaa 12 12 mmmm layer
layer
of cement
of cement mortar
mortar 1:3 1:3 (1 cement :3 3 fine
(1 cement: fine sand)
sand) and finished neat
and finished neat (item
(item ofof
laying
laying brick tiles shall
brick tiles shall bebe paid for separately).
paid for separately). sqm
sqm 532.05
14.88 Providing
Providing and and laying
laying in situ seven
in situ seven course water proofing
course water treatment with
proofing treatment with
APP (Atactic
APP (Atactic Polypropylene)
Polypropylene) modified modified Polymeric
Polymeric memberane
memberane over over roof
roof
consisting of
consisting of first
first coat
coat of of bitumen
bitumen primer primer@@ 0.400.40 litre
litre per
per sqm, 2nd, 4th
sqm, 2nd, 4th
&& 6th courses of of bonding material
material@@ 1.20 kg/sqm, which shall consist of
blown type bitumen of of grade 85/25 conforming to to ISIS:: 702, 3rd and Sth
and 5th
layers
layers ofof roofing
roofing membrane
membrane APP APP modified
modified Polymeric
Polymeric membrane
membrane 2.0mm 2.0 mm
thick of
thick of 3.00
3.00 Kg/sqm
Kg/sqm weightweight consisting
consisting of of five
five layers
layers prefabricated
prefabricated with with
centre core
centre core asas 100 100 micron
micron HMHDPE
HMHDPE film film sandwiched
sandwiched on on both
both sides with
sides with
polymeric mix mix and and the polymeric mix mix is protected on on both side with 20 20
micron
micron HMHDPE
HMHDPE film. film. 7th, the top
7th, the top most
most layer shall be
layer shall finished with
be finished with brick
brick
tiles of
of class designation 10 10 grouted with cement mortar mortar11:3 :3 (1
(1 cement
cement::3 3
fine sand)
fine sand) mixed
mixed with with 2%2% integral
integral waterwater proofing compound by
proofing compound weight of
by weight of
cement overa
cement over a 12 12 mmmm layer
layer of cement mortar
of cement mortar 1:3
1:3((11 cement
cement:3: 3 fine fine sand)
sand)
and finished
and finished neatneat (item
(item of of laying
laying brick tiles shall
brick tiles shall be
be paid for separately).
paid forseparately). sqm
sqm 855.70
14.89 Providing
Providing and and fixingfixing APP APP (Atactic
(Atactic Polypropylene
Polypropylene Polymer) Polymer) modified
modified
prefabricated
prefabricated five five layer
layer22 mm mm thick thick water
water proofing
proofing membrane,
membrane, black black
finished reinforced
finished reinforced with with glass
glass fibre
fibre matt
matt consisting
consisting ofa of a coatcoat ofof bitumen
bitumen
primer forfor bitumen membranemembrane@@ 0.40 litre/sqm by by thethe same membrance
manufacture of ofdensity
density at 25°C, 0.87 - 0.89 kg/ kg/ litre and
and viscocity 70 70 - 160
160
cps. Over theprimer
the primer coat the layer of membrane shall be be laid using Butane
torch and
and sealing all joints etc., and and preparing the surface complete. The The
vital physical and and chemical parameters ofthe of the membrane shall be be asas under
:: Joint strength in longitudinal
longitudinal and and transverse direction at 23°C as 350/300
N/55 cm. Tear strength in longitudinal
N/ longitudinal and and transverse direction as as 60/80N.
Softening
Softening point
point of of membrane
membrane not notlessless than
than 150°C.
150°C. Cold flexibility shall
Cold flexibility shall be
be
upto -2°C when tested in accordance with ASTM,D ASTM, D - 5147. The The laying
of membrane shall be be got
got done through the authorised applicator of the
manufacture of of membrane.
14.89.1
14.89.1 22 mmmm (for corrugated roof
(for corrugated sheets)
roof sheets) sqm
sqm 498.35
14.90 Providing
Providing and and layinglaying APP APP (Atactic
(Atactic Polypropylene
Polypropylene Polymer) Polymer) modified
modified
prefabricated
prefabricated five five layer,
layer, 3 3 mm mm thickthick water
water proofing
proofing membrane,
membrane, black black
finished reinforced
finished reinforced with with glass
glass fibre
fibre matt
matt consisting
consisting ofa of a coatcoat ofof bitumen
bitumen
primer forfor bitumen membrane membrane@@ 0.40 litre/sqm by by thethe same membrane
manufactured ofdensityof density at 25°C, 0.87 - 0.89 kg/litre and and viscocity 70 70 - 160
160
cps. Over theprimer
the primer coat the layer of membrane shall be be laid using butane
torch and
and sealing all joints etc., and and preparing the surface complete. The The
vital physical and and chemical parameters ofthe of the membrane shall be be asas under
:: Joint strength in longitudinal
longitudinal and and transverse direction at 23°C as 350/300
N/5 cm. Tear strength in longitudinal longitudinal and and transverse direction as as 60/80N.

sua HeAD
SUB HEAD:: 14.0
14.0 RePAiRs ro auiLDiNG
REPAIRS TO BUILDING 235
Code No Description Unit Rate
Softening point
Softening point ofof membrane
membrane not less than
notless than 150°C.
150°C. Cold flexibility shall
Cold flexibility shall be
be
upto -2°C when tested in accordance with ASTM,D ASTM, D - 5147. The The laying
of membrane shall be be got
got done through the authorised
authorised applicator of the the
manufacturer of membrane::
of membrane
14.90.1
14.90.1 33 mmmm thick sqm
sqm 537.45
14.91
14.91 Providing
Providing andand laying
laying APPAPP (Atactic
(Atactic Polypropylene
Polypropylene Polymer)
Polymer) modified
modified
prefabricated
prefabricated fivefive layer
layer33 mm thick water
mm thick water proofing
proofing membrane,
membrane, black black
finished reinforced
finished reinforced with with non-woven
non-woven polyester
polyester matt consisting ofa
matt consisting of a coat
coat
of
of bitumen primer for membrane@@ 0.40 litre/sqm by
for bitumen membrane by the
the same
membrane manufacture ofdensity of density at 25°C, 0.87-0.89 kg/ litre and and viscocity
70-160 cps. Over the the primer coat the layer of membrane shall be be laid
using Butane Torch and and sealing all joints etc, andand preparing the surface
complete. TheThe vital physical and and chemical parameters of of the membrane
shall be
be as under:: Joint strength in longitudinal
as under longitudinal and
and transverse direction
at 23°C as 650/ 450N/ 5cm. Scm. Tear strength in longitudinal
longitudinal and
and transverse
direction as
as 300/250N. Softening point of membrane not notless
less than 150°C.
Cold flexibility shall
Cold flexibility shall bebe upto -2°C when
upto -2°C when tested
tested in accordance with
in accordance with ASTM,D
ASTM, D
- 5147. The
The laying of membrane shall be be got
got done through the authorised
applicator of the manufacturer of of membrane
membrane::
14.91.1
14.91.1 33 mmmm thick sqm
sqm 560.95
14.92 Extra for
for covering top of membrane with Geotextile, 120 120 gsm
gsm nonnon woven,
100%
100% polyester
polyester of of thickness
thickness 11 to to 1.25
1.25 mm
mm bonded
bonded to to the
the membrane
membrane
with intermittent touch by heating the membrane by by Butane Torch as per
manufactures recommendation. sqm
sqm 88.90
14.93 Providing round the clock security guard without gun gun for
for watch&
watch & ward of of
Government premises and and its all belongings by deploying neatly dressed
security guards in in8 8 hour’s
hour's shift including necessary T&P T&P like torch, lathi
and etc.compIete,as per the direction of Engineer-in-charge. (One
and uniform etc.complete,as
job means 88 hour’s
jobmeans duty).
hour's duty). each job
job 1308.40
14.94 Providing round the clock security guard with gun gun for
for watch&
watch & ward of of
Government premises and and its all belongings by deploying neatly dressed
security guards in in8 8 hour’s
hour's shift including necessary T&P T&P like torch, lathi
and etc.complete, as
and uniform etc.complete, as per the direction of Engineer-in-charge.(One
job means
job means 88 hour’s duty).
hour's duty). each job
job 1416.50

236
236 SUB HEAD:: 14.0 REPAIRS TO BUILDING
SUB
SUB HEAD
SUB HEAD:: 15.0
DISMANTLING AND
AND
DEMOLISHING
15.0 DISMANTLING AND
AND DEMOLISHING

Code No Description
Description Unit Rate
15.1
15.1 Demolishing lime concrete manually/ by mechanical means and and disposal
of material within 50
50 metres lead as
as per direction of Engineer- in-charge. cum
cum 851.50
15.2 Demolishing cement concrete manually/ by mechanical means including
disposal of material within 50
50 metres lead as
as per direction of Engineer -
in - charge.
15.2.1
15.2.1 Nominal concrete 11:3:6
:3:6 or
or richer mix
mix (including equivalent
design mix)
design mix) cum
cum 2434.25
15.2.2 Nominal concrete 1:4:8 or leaner mix
mix (including
(including equivalent
design mix)
design mix) cum
cum 1503.60
15.3 Demolishing R.C.C. work manually/ by mechanical means including
stacking of steel bars and and disposal of unserviceable material within 50 50
metres lead as as per direction of Engineer - in- charge. cum
cum 3551.25
15.4 Demolishing R.B. work manually/ by mechanical means including
stacking of steel bars and and disposal of unserviceable material within 50 50
metres lead as as per direction of Engineer-in- charge. cum
cum 3177.25
15.5 Extra for
for cutting reinforcement bars manually/ by mechanical means in
R.C.C. or R.B. work (Payment shall be be made on on thecross
the cross sectional area
of R.C.C.
of or R.B.
R.C.C. or work) as
R.B. work) as per
per direction of Engineer-in-charge.
direction of Engineer-in-charge. sqm
sqm 1147.20
15.6 Extra for
for scrapping, cleaning and and straightening
straightening reinforcement from
R.C.C. or R.B. work. kg 9.05
15.7 Demolishing brick work manually/ by mechanical means including
stacking of serviceable material and and disposal of unserviceable material
within 50
50 metres lead as as per direction of Engineer-in-charge.
15.7.1
15.7.1 mud mortar
In mud cum
cum 704.90
15.7.2 In lime mortar with old mughal bricks cum
cum 1783.35
15.7.3 In lime mortar cum
cum 851.50
15.7.4 In cement mortar cum
cum 2060.20
15.8 Removing mortar from bricks and and cleaning bricks including stacking
within a lead
withina lead ofof 50
50 m
m (stacks
(stacks of
of cleaned
cleaned bricks
bricks shall
shall be
be measured):
measured):
15.8.1
15.8.1 From brick work in mud mud mortar Nos
1000 Nos 4658.45
15.8.2 From brick work in lime mortar Nos
1000 Nos 5355.30
15.8.3 From brick work in cement mortar Nos
1000 Nos 6700.80
15.9 Demolishing stone rubble masonry manually/ by mechanical means
including stacking of serviceable material and and disposal of unserviceable
material within 50 50 metres lead asas per direction of Engineer-in-charge
Engineer-in-charge::
15.9.1
15.9.1 In lime mortar cum
cum 1158.10
15.9.2 In cement mortar cum
cum 2458.95
15.10 Dismantling dressed stone work ashlar face stone work, marble work
or precast concrete work manually/ by mechanical means including
or
stacking of serviceable and and disposal of unserviceable material within 50 50
metres lead as as per direction of Engineer-in-charge
Engineer-in-charge::
15.10.1
15.10.1 In lime mortar cum
cum 1464.25
15.10.2 In cement mortar cum
cum 2877.75
15.11
15.11 Removing mortar from and and cleaning stones and and concrete articles (net
quantity of stacks
quantity of stacks of
of cleaned
cleaned materials will be
materials will be measured):
measured):
15.11.1
15.11.1 In lime mortar cum
cum 478.55

SUB HEAD:: 15.0 DISMANTLING AND


SUB AND DEMOLISHING 239
Code No Description
Description Unit Rate
15.11.2 In cement mortar cum
cum 689.20
15.12 Dismantling doors, windows
Dismantling doors, windows andand clerestory
clerestory windows
windows (steel
(steel or wood)
or wood)
shutter including chowkhats, architrave, and
architrave, holdfasts etc. complete and
stacking within 50
50 metres lead
lead::
15.12.1
15.12.1 Of area33 sq.
Of area and below
sq. metres and each 367.20
15.12.2 Of beyond33 sq.
Of area beyond sq.metres
metres each 502.75
15.13 Taking out
Taking doors, windows
out doors, windows and clerestory window
and clerestory window shutters
shutters (steel or wood)
(steel or wood)
including stacking within 50
50 metres lead
lead::
15.13.1
15.13.1 Of area33 sq.
Of area and below
sq. metres and each 143.50
15.13.2 Of Of area beyond3 sq.metres
beyond 3 sq. metres each 188.90
15.14 Dismantling wood work in frames, trusses, purlins and up to 10
and rafters up 10
metres span and5
and 5 metres height including stacking the material within
50 lead::
50 metres lead
15.14.1
15.14.1 Of
Of sectional area 40
40 square centimetres and
and above cum
cum 4459.10
15.14.2 Of sectional area below 40 square centimetres
Of metre 17.85
15.15 Extra for
for dismantling trusses, rafters,
rafters, purlins etc. of wood work forevery
for every
additional span ofone
of one metre or part thereof beyond 10 metres
metres::
15.15.1
15.15.1 Of sectional area 40
Of 40 square centimetres and and above cum
cum per
metre
span 589.55
15.15.2 Of sectional area below 40 square centimetres
Of metre per
metre
span 1.65
15.16 Extra for
for dismantling trusses, rafters,
rafters, purlins etc. of wood work forevery
for every
additional height of one or part thereof beyond
one metre or beyond55 metres
metres::
15.16.1
15.16.1 Of sectional area 40
Of 40 square centimetres andand above cum per
cum
metre
height 857.00
15.16.2 Of sectional area below 40 square centimetres
Of per
metre per
metre
height 3.40
15.17 Dismantling steel work in single sections including dismembering and
and
stacking within 50
50 metres lead in:
15.17.1
15.17.1 R.S. Joists kg 3.40
15.17.2 Channels,
Channels, angles, tees and
angles, tees and flats
flats kg 2.30
15.18 Dismantling
Dismantling steel work in
steel work in built
built up sections in
up sections angles, tees,
in angles, tees, flats
flats and
and
channels including all gusset plates, bolts, nuts, cutting rivets, welding
etc. including dismembering and
and stacking within 50
50 metres lead. kg 5.65
15.19 Dismantling steel work manually/ by mechanical means in built up up
sections without dismembering and
and stacking within 50
50 metres lead as
as per
direction of Engineer-in-charge. kg 3.85
15.20 Extra for
for dismantling trusses, rafters, purlins etc. of steel work forevery
for every kg per
additional span of
ofone or part thereof beyond 10 metres
one metre or metre
span 0.85
15.21
15.21 Extra for
for dismantling trusses, rafters, purlins etc. of steel work forevery
for every kg per
one metre or
additional height of one or part thereof beyond
beyond55 metres. metre
height 0.85
15.22 Extra for
for marking of
of structural steel work required to be
be re-erected.
re-erected. kg 4.65

240
240 SUB HEAD:: 15.0 DISMANTLING AND
SUB DEMOL•ISHING
AND DEMOLISHING
Code No Description
Description Unit Rate
15.23 Dismantling tile work
Dismantling tile work in floors and
in floors and roofs
roofs laid
laid in cement mortar
in cement mortar including
including
stacking material within 50
50 metres lead.
15.23.1
15.23.1 For thickness of tiles 10
For 10 mm
mm to
to 25 mm
25 mm sqm
sqm 73.40
15.23.2 For thickness of tiles above 25 mm
mm and up to40 mm
to 40 mm sqm
sqm 113.35
15.24 Demolishing
Demolishing drydry brick
brick pitching
pitching in floors, drains
in floors, etc. including
drains etc. including stacking
stacking ofof
serviceable material andand disposal of unserviceable material within 50 50
lead::
metres lead cum
cum 1317.65
15.25 Dismantling stone slab
Dismantling stone slab flooring
flooring laid
laid in cement mortar
in cement mortar including stacking
including stacking
of serviceable material and
and disposal of unserviceable material within 50 50
metres lead. sqm
sqm 266.45
15.26 Demolishing brick tile covering in terracing including stacking of
serviceable material andand disposal of unserviceable material within 50 50
metres lead. sqm
sqm 105.35
15.27 Demolishing mudmud phaska in terracing and and disposal of material within 50 50
metres lead. cum
cum 914.30
15.28 Dismantling
Dismantling roofing
roofing including
including ridges,
ridges, hips, valleys and
hips, valleys and gutters
gutters etc.,
etc., and
and
stacking the material within 5050 metres lead of:
15.28.1
15.28.1 G.S. Sheet sqm
sqm 164.95
15.28.2 Asbestos Cement sheet sqm
sqm 77.30
15.29 Dismantling
Dismantling stone slab roofing
stone slab over wooden
roofing over wooden karries or R.C.C.
karries or R.C.C. battens
battens
(dismantling
(dismantling karries and battens
karries and to be
battens to be paid for separately),
paid for separately), including
including
stacking of serviceable material and and disposal of unserviceable material
within 50
50 metres lead. cum
cum 2664.65
15.30 Dismantling jack arch
Dismantling jack arch roofing and floors
roofing and floors including stacking of
including stacking of serviceable
serviceable
material and
and disposal of unserviceable material within 50 50 metres lead. sqm
sqm 253.90
15.31
15.31 Dismantling tiled roofing
Dismantling tiled with battens,
roofing with battens, boarding
boarding etc.
etc. complete
complete including
including
stacking of serviceable material and and disposal of unserviceable material
within 50
50 metres lead. sqm
sqm 209.90
15.32 Demolishing thatch roofing
Demolishing thatch roofing including
including mats,
mats, bamboo, jaffari etc.
bamboo, jaffari etc. complete
complete
including stacking of serviceable material and and disposal of unserviceable
material within 50 50 metres lead. sqm
sqm 57.70
15.33 Dismantling wooden ballies in posts and and struts including stacking within
50metres lead. metre 20.95
15.34 Dismantling and
and stacking within 50 50 metres lead, fencing posts or struts
including all earth work and dismantling of concrete etc. in base of:
15.34.1
15.34.1 T’ or ‘L’ iron or pipe each 230.90
15.34.2 R.C.C. each 243.30
15.35 Cutting ballies or wooden posts offencing
of fencing at the point of projection above
theconcrete
the concrete or ground and
and stacking the same within 50 50 metres lead. each 13.45
15.36 Dismantling
Dismantling barbed wire or
barbed wire or flexible
flexible wire
wire rope
rope in fencing including
in fencing including making
making
rolls and
and stacking within 50
50 metres lead. kg 36.80
15.37 Dismantling wooden trellis work excluding frames but but including stacking
the serviceable material within 50 50 metres lead. sqm
sqm 64.85
15.38 Dismantling expanded metal or I.R.C. fabrics with necessary battens and and
beading including stacking the serviceable material within 50 50 metres lead. sqm
sqm 75.80
15.39 Dismantling wooden boardings in lining of walls and partitions, excluding
and partitions,
supporting members but butincluding
including stacking within 50 lead::
50 metres lead
15.39.1
15.39.1 Up to 10
Up to 10 mm thick
mm thick sqm
sqm 61.00
15.39.2 Thickness above 10 mm mm up to25 mm
to 25 mm sqm
sqm 77.75

SUB HEAD:: 15.0 DISMANTLING AND


SUB AND DEMOLISHING 241
241
Code No Description
Description Unit Rate
15.39.3 Thickness above 25 mm
mm up to40 mm
to 40 mm sqm
sqm 90.35
15.40 Dismantling precast concrete or stone slabs in walls, partition
partition walls etc.
including stacking within 50
50 metres lead
lead::
15.40.1
15.40.1 Thickness up to
to 40 mm
40 mm sqm
sqm 289.30
15.40.2 Thickness above 40 mm
mm up to75 mm
to 75 mm sqm
sqm 433.55
15.41
15.41 Dismantling cement asbestos or other hard board ceiling or partition walls
or partition
and disposal of unserviceable
including stacking of serviceable materials and
materials within 50
50 metres lead. sqm
sqm 56.35
15.42 Dismantling
Dismantling C.I. or asbestos
C.I. or asbestos rain water pipe
rain water with fittings
pipe with fittings and
and clamps
clamps
including stacking the material within 50
50 metres lead
lead::
15.42.1
15.42.1 75
75 to 80 mm dia pipe
80 mm metre 75.70
15.42.2 100 100 mmmm dia pipe metre 78.00
15.42.3 150 150 mmmm dia pipe metre 80.25
15.43 Dismantling manually/ by mechanical means including stacking of
serviceable material and and disposal of unserviceable material within 50 50
metres lead asas per direction of Engineer-in-charge
Engineer-in-charge::
15.43.1 Water bound macadam road
15.43.1 sqm
sqm 217.45
15.43.2 bituminous road sqm
sqm 428.50
15.44 Dismantling
Dismantling G.I.
G.I. pipes
pipes (external work) including
(external work) excavation and
including excavation and refilling
refilling
trenches after taking out the pipes, manually/ by mechanical means
including stacking of pipes within 50 50 metres lead as as per direction of
Engineer-in-charge::
Engineer-in-charge
15.44.1
15.44.1 15 mm
15 mm to 40 mm nominal bore
40 mm metre 149.80
15.44.2 Above 40 mm mm nominal bore metre 161.40
15.45 Dismantling
Dismantling C.I.
C.I. pipes
pipes including excavation and
including excavation and refilling trenches after
refilling trenches after
taking out the
the pipes, manually/ by mechanical means breaking lead caulked
joints, melting of lead and
and making into blocks including stacking of pipes
&& lead at site within 50
50 metre lead asas per direction of Engineer-in-charge:
15.45.1
15.45.1 Up
Up toto 150
150 mm
mm diameter
diameter metre 332.40
15.45.2 Above 150 150 mm
mm diaup
dia up to300 mm dia
to 300 mm dia metre 456.65
15.45.3 Above 300 mm mm diameter metre 614.30
15.46 Dismantling steel cylinder
Dismantling steel cylinder R.C.
R.C. pipes
pipes including
including excavation
excavation and
and refilling
refilling
trenches after taking out the pipes, manually/ by mechanical means
breaking lead caulked joints, melting of lead and and making into blocks
including stacking of pipespipes&& lead at site within 50
50 metres lead asas per
direction of Engineer-in-charge
Engineer-in-charge::
15.46.1
15.46.1 Up to 600
Up to 600 mm
mm diameter
diameter metre 695.25
15.46.2 Above 600 mm mm diameter metre 1752.45
15.47 Dismantling asbestos cement pressure pipes including excavation and and
refilling trenches after
refilling trenches after taking
taking out
out the
the pipes
pipes manually/
manually/ by
by mechanical
mechanical
means and and stacking the pipes within 50 50 metres lead asas per direction of
Engineer-in-charge::
Engineer-in-charge
15.47.1
15.47.1 Up to 150
Up to 150 mm diameter
mm diameter metre 332.15
15.47.2 Above 150 150 mm
mm diameter metre 403.05
15.48 Taking out C.I. cover with frame from R.C.C. top slab of manholes
of
of various sizes including demolishing of of R.C.C. work manually/ by
mechanical means and and stacking of useful materials near thethe site and
and
disposal of unserviceable materials within 50 50 metres lead as
as per direction
of Engineer-in-charge. each 697.40

242
242 SUB HEAD:: 15.0 DISMANTLING AND
SUB DEMOL•ISHING
AND DEMOLISHING
Code No Description
Description Unit Rate
15.49 Taking out C.I. cover with frame from R.C.C. top slab of inspection
chambers ofvarious
of various sizes including demolishing ofR.C.C.
of R.C.C. work manually/
by mechanical means and and stacking of useful materials near the site and
and
disposal of unserviceable materials within 50 as per direction
50 metres lead as
of Engineer-in-charge. each 406.75
15.50 Dismantling of R.C.C. spun vent shaft including excavating the cement
concrete pit
concrete completely, taking
pit completely, taking out the shaft,
out the shaft, refilling the excavated
refilling the gap,
excavated gap,
stacking the useful materials near the and disposal of unserviceable
the site and
materials within 50
50 metres lead. each 4623.70
15.51
15.51 Dismantling of road gully chamber of ofvarious
various sizes including C.I. grating
with frame including stacking of useful materials near thesite and disposal
the site and
of unserviceable
of unserviceable materials within 50
materials within 50 metres
metres lead
lead including
including refilling the
refilling the
excavated gap. each 958.75
15.52 Dismantling
Dismantling ofof flushing
flushing cistern
cistern of
of all
all types
types (C.I./PVC/Vitrious
(C.I./PVC/Vitrious China)
China)
including stacking of useful materials near the site and and disposal of
unserviceable materials within 50 50 metres lead. each 112.05
15.53 Dismantling of C.I. sluice valve including stacking of useful materials
withina
within a lead of 50
50 metres
15.53.1
15.53.1 Up to 150
Up to 150 mm diameter
mm diameter each 319.50
15.53.2 Above 150 150 mm
mm diameter each 1184.15
15.54 Dismantling
Dismantling ofof spindle fire hydrant
spindle fire hydrant including stacking of
including stacking of useful
useful materials
materials
within 50
50 metres lead. each 726.35
15.55 Dismantling of cement concrete platform along with curtain walls and and
base concrete etc. including stacking of useful materials near the the site
and
and disposal of unserviceable materials within 50 lead::
50 metres lead
15.55.1
15.55.1 120
120xx 120
120 cm
cm (outside to outside)
(outside to outside) each 1104.05
15.55.2 210 210xx 120
120 cm
cm (outside to outside)
(outside to outside) each 1693.35
15.55.3 320 320xx 120
120 cm
cm (outside to outside)
(outside to outside) each 2396.95
15.56 Dismantling old plaster or skirting raking out joints and and cleaning the
surface forfor plaster including disposal of rubbish to the dumping ground
within 5050 metres lead. sqm
sqm 54.65
15.57 Dismantling aluminium/ Gypsum
Dismantling aluminium/ Gypsum partitions,
partitions, doors, windows, fixed
doors, windows, fixed glazing
glazing
and
and false ceiling including disposal of unserviceable material and and stacking
of serviceable material with in 50 50 meters lead as as directed by by Engineer-
in-charge. sqm
sqm 56.35
15.58 Demolishing R.C.C. work by mechanical means and and stockpiling at
designated locations and and disposal of dismantled materials up up toa
to a lead of
11 kilometre,
kilometre, stacking serviceable andand unserviceable material separately
including cutting reinforcement bars. cum
cum 2818.90
15.59 Dismantling
Dismantling of of flexible
flexible pavement
pavement (bituminous courses) by
(bituminous courses) by mechanical
mechanical
means and and disposal of dismantled material up up toa
to a lead of1
of 1 kilometre, as
as
per direction of Engineer-in-charge.
per cum
cum 420.80
15.60 Disposal of of building rubbish
rubbish// malba
malba// similar unserviceable, dismantled
or waste materials by by mechanical means, including loading, transporting,
transporting,
unloading to approved municipal dumping ground or or as approved by
Engineer-in-charge, beyond 50 m m initial lead, for all leads including all
lifts involved. cum
cum 263.95

SUB HEAD:: 15.0 DISMANTLING AND


SUB AND DEMOLISHING 243
SUB HEAD
SUB HEAD:: 16.0
ROAD WORK
16.0 ROAD WORK

Code No Description Unit Rate


ROADS
16.1
16.1 Preparation and
and consolidation of sub
sub grade with power road roller of8
of 8 to
to
12 tonne capacity after excavating earth to an
12 an average of
of 22.5 cm
cm depth,
dressing to camber and consolidating with road roller including making
good the
the undulations etc. and re-rolling the
and re-rolling the sub and disposal of
sub grade and
surplus earthwith lead upto 50
50 metres. sqm
sqm 218.90
16.2 Extra for
for compaction of of earth work in embankment under optimum
moisture conditions to
moisture conditions to give
give at
at least
least 95% of the
95% of the maximum dry density
maximum drydensity
(proctor density).
(proctor density). cum
cum 24.85
16.3 and stacking at site.
Supplying and
16.3.1
16.3.1 90 mm
90 mm to 45 mm size stone aggregate
45 mm cum
cum 2098.40
16.3.2 63 mm
63 mm to 45 mm size stone aggregate
45 mm cum
cum 1636.05
16.3.3 53 mm
53 mm to 22.4 mm
mm size stone aggregate cum
cum 1842.30
16.3.4 Over
Over burnt
burnt (Jhama)
(Jhama) brick aggregate 120
brick aggregate 120 mm to 40
mm to 40 mm
mm cum
cum 798.10
16.3.5 Over
Over burnt
burnt (Jhama)
(Jhama) brick aggregate 90
brick aggregate 90 mm to 45
mm to 45 mm
mm cum
cum 872.05
16.3.6 Stone screening 13.2
Stone screening 13.2 mm
mm nominal size (Type
nominal size A)
(Type A) cum
cum 2034.35
16.3.7 Stone screening 11.2
Stone screening 11.2 mm
mm nominal size (Type
nominal size (Type B)
B) cum
cum 2247.75
16.3.8 Red bajri
Red cum
cum 1564.90
16.3.9 Good earth cum
cum 775.50
16.3.10 Moorum cum
cum 768.25
16.4 Laying, spreading and
Laying, spreading and compacting
compacting stone
stone aggregate
aggregate ofof specified
specified sizes
sizes
to WBM
to WBM specifications
specifications in in uniform thickness, hand
uniform thickness, hand picking,
picking, rolling with 3
rolling with3
wheeled road/vibratory roller 8-10 tonne capacity in stages to to proper grade
and camber, applying and
and and brooming requisite type of screening/
screening / binding
material to fill
material to fill up
up interstices of coarse
interstices of coarse aggregate,
aggregate, watering
watering and compacting
and compacting
tothe
to the required density.
density . cum
cum 1046.95
16.5 Laying water bound macadam sub-base with brick aggregate and and binding
material, earth etc. including screening, sorting and
material, and spreading to to template
and consolidation with light power road-roller etc. complete.(payment for
and for
brick aggregate and
brick aggregate and moorum
moorum etc. to be
etc. to be made
made separately)
separately)
16.5.1
16.5.1 Over
Over burnt
burnt (Jhama)
(Jhama) brick aggregate 120
brick aggregate 120 mm
mm toto 40
40 mmmm cum
cum 879.70
16.5.2 Over
Over burnt
burnt (Jhama)
(Jhama) brick aggregate 90
brick aggregate 90 mm
mm toto 45
45 mm
mm cum
cum 879.70
16.6 Supplying, stacking and
Supplying, and Spreading
Spreading66 mm mm thick red
red bajri, watering and and
rolling complete including preparation of the surface and rolling.
and rolling.
16.6.1
16.6.1 With road roller/ hand roller sqm
sqm 24.45
16.7 Brick edging in full brick width and
and half brick depth including excavation,
excavation,
refilling and disposal
refilling and disposal of
of surplus earth lead
surplus earth lead upto 50 metres.
upto 50 metres.
16.7.1
16.7.1 With common
With common burnt
burnt clay
clay F.P.S.
F.P.S. (non
(non modular)
modular) bricks of class
bricks of class
designation 7.5 metre 194.30
16.8 Brick edging laid lengthwise with half brick depth including excavation,
excavation,
refilling and disposal
refilling and disposal of
of surplus
surplus earth
earth lead
lead upto
upto 50
50 metres
metres::
16.8.1
16.8.1 With common
With common burnt
burnt clay
clay F.P.S.
F.P.S. (non
(non modular)
modular) bricks of class
bricks of class
designation 7.5 metre 53.45
16.9 Scarifying
Scarifying metalled
metalled (water-bound)
(water-bound) road
road surface
surface including disposal of
including disposal of
50 m
rubbish, lead upto 50 m and
and consolidation of the aggregate received from
scarifying with power road roller of8
of 8 to 10 tonne capacity.
to 10 capacity. sqm
sqm 33.30

SUB HEAD:: 16.0 ROAD WORK


SUB WORK 247
247
Code No Description Unit Rate
16.10 Making bajri path including preparation of subgrade, supplying and
and laying
brick aggregate of 50 mm
of 50 mm nominal size 7.5 cm
cm deep with blinding material
12 mm
consisting of 12 mm moorum and 12 mm
and 12 mm red
redbajri
bajri consolidated with road
roller.
roller. sqm
sqm 191.25
16.11
16.11 Dry stone pitching 22.5 cm
Dry cm thick including supply of
of stones and
and preparing
surface complete. sqm
sqm 883.15
16.12 Dry brick pitching half brick thick in drains including supply of
Dry of bricks and
and
preparing the surface complete
complete::
16.12.1
16.12.1 With common
With common burntburnt clay
clay F.P.S.
F.P.S. (non(non modular)
modular) bricks
bricks ofof class
class
designation 7.5 sqm
sqm 644.05
16.13 Cutting road and and making good the the same including supply of of extra
aggregate, moorum screening, red bajri and
quantities of materials i.e. aggregate, and
labour required.
16.13.1
16.13.1 bituminous portion cum
cum 5032.25
16.13.2 Water bound macadam cum
cum 3078.05
16.14 Cutting bajri paths and and making good the the same including supply of of extra
quantities of brick aggregate, moorum and redbajri
and red bajri required. sqm
sqm 284.20
FENCING
16.15 Supplying atat site
site::
16.15.1
16.15.1 R.C.C. Standards post/ posh struts/rails/ pales of mix mix 11:1.5:3
:1.5:3 (1
(1
cement:: 1.5
cement 1.5 coarsesand:3
coarsesand : 3 graded stone aggregate 12.5 mm mm
nominal
nominal size) with wooden
size) with wooden plugsplugs or6or 6 mm
mm bar
bar nibs wherever
nibs wherever
required as as per direction of Engineer-in- charge (cost of earth
works in excavation,
excavation, concrete works in foundation to be be paid
separately).
separately). cum
cum 32891.20
16.15.2 Welded steel wire fabric of required width having rectangular
mesh painted with two two or more coats of of enamel paint of
approved shade overa over a coat of (Priming&& Painting to
of primer (Priming
be
be paid for separately).
paid forseparately). kg 78.95
16.16 Supplying and
Supplying and fixing
fixing turn
turn buckles
buckles andand straining
straining bolts for barbed
bolts for wire
barbed wire
fencing. set
each set 274.30
16.17 Fencing with R.C.C. post placed at atrequired
required distance, embedded in cement
concrete blocks, every 15th post, last but but one
one endend post and
and corner post
shall be
be strutted onon both sides and and end
end post one one side only, provided with
and two
horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 100
metres
metres (minimum),
(minimum), between the two posts
between thetwo fitted and
posts fitted and fixed
fixed with
with G.I. staples
G.I. staples
on wooden
on wooden plugs
plugs oror G.I.
G.I. binding wire tied
binding wire tied to6
to 6 mm
mm barbar nibs fixed while
nibs fixed while
casting the post (cost of R.C.C. posts, struts, earth work and concrete to
be
be paid for separately) :- Payment
paid forseparately):- to be made
Payment tobe made per metre cost
permetre of total
cost of total length
length
of barbed wire used.
16.17.1
16.17.1 With G.I. barbed wire metre 14.00
16.18 Fencing with angle iron post placed at at required distance embedded in
cement concrete blocks, every 15th post, last but but one
one end
end post and
and corner
post shall bebe strutted onon both sides and
and end
end post onon one and
one side only and
provided with horizontal lines andand two
two diagonals interwoven with horizontal
wires, of
wires, of barbed wire weighing
barbed wire weighing 9.38
9.38 kg
kg per
per 100
100 mm (minimum),
(minimum), between the
between the
two posts
two fitted and
posts fitted fixed with
and fixed with G.I.
G.I. staples, turn buckles
staples, turn etc. complete.
buckles etc. complete. (Cost
(Cost
of posts,
of posts, struts, earth work
struts, earth work and concrete work
and concrete work to
to be
be paid for separately).
paid for separately).
Payment tobe
to be made per permetre
metre cost of total length of barbed wire used.
16.18.1
16.18.1 With G.I. barbed wire metre 22.10

248
248 sua HEAD
SUB HeAD:: 16.0
Ys.o ROAD
RodO WORK
woRf
Code No Description Unit Rate
16.19 Supplying at at site Angle iron post
post&& strut of required size including bottom
to be split and
to be and bent atat right angle in opposite direction for 10
10 cm
cm length and
and
drilling holes upto 1010 mm
mm dia. etc. complete. kg 125.75
16.20 Welded steel
Welded wire fabric
steel wire fabric fencing
fencing with
with posts
posts of specified material
of specified and of
material and of
standard design placed and and embedded in cement concrete blocks 45x45x
60 cm of
60 cm of mix
mix 1:5:10
1:5:10 (1 cement:5 fine
(1 cement:5 fine sand
sand:: 10 graded stone
10 graded stone aggregate
aggregate
40 mm
40 mm nominal
nominal size),
size), every
every 15th
15th post,
post, last
last but
but one
one end
end post and corner
post and corner
post shall bebe strutted on
on both sides andand end
end post on on one
one side only and and
struts embedded in cement concrete blocks 70x45x50 cm cm ofthesame
of the same mix,
provided with welded
provided with welded steel
steel wire
wire fabric
fabric fixed
fixed between
between thethe posts fitted and
posts fitted and
fixed with
fixed with G.I. staples on
G.I. staples on wooden
wooden plugs
plugs oror tied
tied to6
to 6 mm
mm bar
bar nibs with G.I.
nibs with G.I.
binding wire (cost of posts, welded steel wire fabric, painting, earth work in
excavation
excavation andand concrete
concrete toto be
be paid for separately).
paid for separately). sqm
sqm 66.15
ROAD SIGNS
16.21
16.21 Engraving letters in hard stone per cm
cm
height per
letter 10.55
16.22 Providing
Providing and fixing 15x15x90
and fixing 15x15x90 cm cm boundary
boundary stone of hard
stone of stone with
hard stone with top
top
30 cm
30 cm chisel dressed on on all four sides including top
top (cost of excavation,
refilling and concrete
refilling and concrete etc. to be
etc. to be paid for separately).
paid for separately). each 252.90
16.23 Providing and fixing
Providing and fixing 15 cm dia
15 cm dia at
at top,
top, 20
20 cm
cm atat bottom and 90
bottom and 90 cm
cm high
high
precast reinforced cement concrete
concrete11:1.5:3
:1.5:3 (1
(1 cement
cement:: 1.5
1.5 coarse sand:
33 graded
graded stone
stone aggregate
aggregate 20 20 mmmm nominal size) boundary
nominal size) boundary stone
stone as
as per
per
standard
standard design,
design, including finishing smooth
including finishing with cement
smooth with cement mortar
mortar 1:3
1:3 (1
(1
cement
cement::3 3 fine
fine sand)
sand) (cost
(cost of
of excavation,
excavation, refilling
refilling and
and concreting to be
concreting to be
paid for separately).
paid for separately). each 852.40
16.24 Providing
Providing and fixing precast
and fixing precast reinforced
reinforced cement concrete 11:1.5:3
cement concrete :1.5:3 (1
(1
cement:
cement: 1.5 coarse sand:
1.5coarse sand :3 3 graded
graded stone
stone aggregate
aggregate 20 20 mm
mm nominal size)
nominal size)
kilometre
kilometre stone
stone as
as per
per standard design, including
standard design, finishing smooth
including finishing smooth inin11:3
:3
cement
cement mortar
mortar (1
(1 cement
cement::3 3 fine
fine sand)
sand) but
but excluding the cost
excluding the cost of
of earth
earth
work, concrete in foundation, painting and
and lettering etc. which shall be
be paid
forseparately.
for separately.
16.24.1
16.24.1 cm size
35x111x25 cm each 2876.70
16.24.2 cm size
50x152.5x25 cm each 5170.25
16.24.3 cm size
35x93.5x18 cm each 1924.50
SURFACE DRESSING
16.25 Surface dressing on
Surface dressing on new
new surface with paving
surface with paving bitumen of grade
bitumen of VG -- 10
grade VG 10 of
of
approved quality using 2.25 kg of of bitumen per sqm
sqm with 1.65 cum
cum of stone
mm nominal size per
chippings 13.2 mm per 100
100 sqm
sqm of road surface, including
consolidation with road roller of6
of 6 to8
to 8 tonne capacity etc. complete: sqm
sqm 225.35
16.26 Surface dressing on
Surface dressing on new surface in
new surface two coats
in two coats with
with bitumen of grade
bitumen of grade VGVG
-10 ofof approved quality using 1.8 kg
kg of bitumen per sqmsqm with 1.5 cum
cum of
stone chippings 13.2 mm mm nominal size per 100100 sqm
sqm of road surface for for
first coat
first coat and
and 1.1
1.1 kg.
kg. of
of bitumen
bitumen per sqm with
per sqm with 1.00
1.00 cu.
cu. metre
metre of
of stone
stone
chippings 11.2 mm mm nominal size per
per 100
100 sqm
sqm of road surface for
for second
coat, including consolidation of each coat separately with road roller of
of6 6 to
to
8 8 tonne capacity etc. complete. sqm
sqm 311.85
16.27 Surface
Surface dressing
dressing onon old surface with
old surface with hot
hot bitumen
bitumen ofof grade VG -- 10
grade VG 10 of
of
approved quality using 1.95 kg of bitumen per sqm sqm with 1.50 cum
cum of stone
mm nominal size per
chippings 11.2 mm per 100
100 sqm
sqm of road surface, including
consolidation with road roller of6
of 6 to8
to 8 tonne capacity,
capacity, etc. complete. sqm
sqm 175.10

sua HeAD
SUB HEAD:: 16.0
16.0 RoAD woRK
ROAD WORK 249
249
Code No Description Unit Rate
16.28 Surface dressing one
Surface dressing one coat on new
coat on surface with
new surface with bitumen of specified
bitumen of grade
specified grade
ataa rate of 1.95 kg/sqm of
at of surface area with 1.5 cum
cum of stone chippings
mm nominal size per 100
13.2 mm 100 sqm
sqm of road surface, including consolidation
with road roller of6
of 6 to8
to 8 tonne capacity,
capacity , etc. complete:
complete :
16.28.1
16.28.1 Using
Using bitumen
bitumen emulsion
emulsion (minimum
(minimum 50%
50% bitumen content- RS
bitumen content- RS
grade conforming
grade conforming to to IS
IS:: 8887)
8887) sqm
sqm 198.45
16.29 Surface dressing one
Surface dressing one coat
coat on
on old
old surface
surface with
with bitumen
bitumen ofof specified grade
specified grade
atthe
at the rate of 1.22 kg/ sqm
sqm of surface area with 1.10 cum cum of stone chippings
mm nominal size per 100
11.2 mm 100 sqm
sqm of road surface, including consolidation
with road roller of6
of 6 to8
to 8 tonne capacity etc. complete:
complete :
16.29.1
16.29.1 Using
Using bitumen
bitumen emulsion
emulsion (minimum
(minimum 50%
50% bitumen content- RS
bitumen content- RS
grade conforming
grade conforming to to IS
IS:: 8887)
8887) sqm
sqm 125.30
PREMIX CARPET
16.30 Providing andand applying tack coat using hot straight run run bitumen of of
grade
grade VGVG -- 10,
10, including
including heating the bitumen,
heating the bitumen, spraying the bitumen
spraying the with
bitumen with
mechanically operated spray
mechanically operated spray unit fitted on
unit fitted on bitumen
bitumen boiler, cleaning and
boiler, cleaning and
preparing the existing
preparing the existing road surface as
road surface as per specifications :
per specifications:
16.30.1
16.30.1 On W.B.M.@
On W.B.M. @ 0.75 Kg Kg// sqm
sqm sqm
sqm 60.50
16.30.2 On bituminous surface
On surface@@ 0.50 Kg Kg// sqm
sqm sqm
sqm 48.20
16.31
16.31 Providing andand applying tack coat using bitumen emulsion conforming
to IS:8887, using emulsion pressure distributer including preparing the
to IS:8887,
surface&& cleaning with mechanical broom.
surface
16.31.1
16.31.1 With rapid setting bitumen emulsion
16.31.1.1
16.31.1.1 On W.B.M/
On W.B.M / W.M.M.@
W.M.M. @ 0.4kg/sqm sqm
sqm 13.45
16.31.1.2 On bituminous surface
On surface@@ 0.25kg/sqm sqm
sqm 9.20
16.31.2 With medium setting bitumen emulsion
16.31.2.1
16.31.2.1 On W.B.M/
On W.B.M / W.M.M.@
W.M.M. @ 0.4kg/sqm sqm
sqm 21.20
16.31.2.2 On bituminous surface
On surface@@ 0.25kg/sqm sqm
sqm 14.05
Note
Note -- Use
Use of
of Item
Item No.
No. 16.81.1 shall be
16.81.1 shall be restricted only per
restricted only site
per site
at sub
sub zero temperature or foremergency
for emergency application
16.32 22 cm
cm premix carpet surfacing with 1.8 cum cum and and 0.90 cum cum of of stone
chippings of 13.2 mmmm size and
and 11.2 mmmm size respectively per per 100
100 sqm and
sqm and
52 kg
52 kg and
and 56
56 kg
kg of hot bitumen per cum cum of
of stone chippings of of 13.2 mmmm
and mm size respectively,
and 11.2 mm respectively, including
includingaa tack coat with hot straight run run
bitumen, including consolidation with road roller of of6 6 to9
to 9 tonne capacity
etc. complete
etc. complete (tack coat to
(tack coat to be
be paid for separately).
paid forseparately).
16.32.1
16.32.1 With paving
With Asphalt grade
paving Asphalt grade VG
VG -- 1010 heated
heated and then mixed
and then mixed
with solvent at the rate of 70 70 grams perperkg ofasphalt
kg of asphalt sqm
sqm 234.05
16.32.2 With paving
With Asphalt grade
paving Asphalt grade VG
VG -- 30
30 with
with no solvent
no solvent sqm
sqm 245.15
16.32.3 With Refinery
With Refinery Modified
Modified Bitumen
Bitumen CRMB
CRMB 55 conforming to
55conforming to IRC:
IRC:
SP: 53
SP: 53 sqm
sqm 233.15
16.33 2.5 cm
cm premix carpet surfacing with 2.25 cum cum andand 1.12 cum cum of stone
chippings of
of 13.2 mmmm and
and 11.2 mm mm size respectively per per 100
100 sqm
sqm andand
52 kg and
52 kg and 56
56 kg
kg of hot bitumen per cum cum of
of stone chippings of of 13.2 mmmm
and mm size respectively,
and 11.2 mm respectively, including
includingaa tack coat with hot straight run run
bitumen, including consolidation with road roller of of6 6 to9
to 9 tonne capacity
etc. complete
etc. complete (tack coat to
(tack coat to be
be paid for separately).
paid forseparately).
16.33.1
16.33.1 With paving
With Asphalt grade
paving Asphalt grade VG
VG -- 1010 heated
heated and then mixed
and then mixed
with solvent at the rate of 70 70 grams perperkg kg ofasphalt
of asphalt sqm
sqm 281.00

250
250 sua HEAD
SUB HeAD:: 16.0
Ys.o ROAD
RodO WORK
woRf
Code No Description Unit Rate
16.33.2 With paving
With Asphalt grade
paving Asphalt grade VGVG -- 30 with no
30 with solvent
no solvent sqm
sqm 294.95
16.33.3 With Refinery
With Refinery Modified
Modified Bitumen
Bitumen CRMB
CRMB 55 conforming to
55conforming to IRC:
IRC:
SP: 53
SP: 53 sqm
sqm 279.90
16.34 22 cm
cm premix carpet surfacing with 2.4 cum cum of stone chippings 11.2 mm mm
nominal size per 100 100 sqm
sqm and
and bitumen emulsion (medium setting min.
65%
65% bitumen content) complying
bitumen content) complying withwith IS
IS:: 8887,
8887, using
using 96 96 kg
kg per
per cum
cum ofof
chippings, including consolidation with road roller of6
chippings, of 6 to9
to 9 tonne capacity
etc. complete. sqm
sqm 208.90
16.35 2.5 cm
cm premix carpet surfacing with3 with 3 cum
cum of stone chippings 10 10 mm
mm
nominal size per 100 100 sqm
sqm and
and bitumen emulsion (medium setting min.
65%
65% bitumen
bitumen contents)
contents) complying
complying withwith IS
IS:: 8887,
8887, using
using 9696 kg
kg per
per cum
cum
of chippings of road surface, including consolidation with road roller etc
of etc
complete..
complete sqm
sqm 252.15
16.36 Providing and Penetration Macadam with hard stone
and laying Bitumen Penetration
aggregate
aggregate of quality, size
ofquality, size and
and grading
grading as specified, with
as specified, with bitumen of suitable
bitumen ofsuitable
penetration grade, including
penetration grade, including required
required key aggregate as
key aggregate as specified,
specified, spreading
spreading
coarse aggregate with the help of self propelled/ tipper tail mounted
aggregate spreader and and applying bitumen by aa pressure distributor
and then spreading key aggregate with the help of aggregate spreader
and
complete, including consolidation with road roller of minimum minimum88 to10to 10 tonne
capacity to achieve
capacity to specified values
achieve specified values of of compaction
compaction and and surface
surface accuracy
accuracy::
16.36.1
16.36.1 For 50
For mm compacted thickness using coarse aggregate of
50 mm of
size 50-20 mm mm graded@
graded @ 0.60 cum cum per 10 sqmsqm key aggregate
ofsize
of size 12.5 mmmm graded@
graded @ 0.15 cum cum per 10 sqm. With paving
asphalt grade VG
asphalt grade VG -- 10
10 @ @ 50
50 kg/
kg/ 1010 sqm.
sqm. sqm
sqm 505.65
16.36.2 For 7575 mmmm compacted thickness in two two layers using stone
aggregate of of size 63-41
63-41 mm mm graded
graded@@ 0.90 cum cum per 10 sqmsqm
key aggregate of of size 20.0 mm mm graded
graded@@ 0.18 cum cum per 10
sqm. With paving
sqm. With asphalt grade
paving asphalt grade VGVG -- 10
10 @ @ 68
68 kg/10
kg/10 sqm.
sqm. sqm
sqm 744.15
16.37 Providing
Providing and
and laying
laying bitumen
bitumen mastic wearing course
mastic wearing course (as
(as per
per specifications)
specifications)
with industrial bitumen of of grade 85/25 conforming to IS:: 702, prepared by
to IS
using mastic cooker and and laid to
to required level andand slope, including providing
antiskid surface with
antiskid surface with bitumen
bitumen precoated
precoated finefine grained
grained hard stone chipping
hard stone chipping
of approved size at the the rate of 0.005 cum cum per 10 sqmsqm andand at
at approximate
spacing of
of 10 cmcm centre to centre in both directions,
directions, pressed into surface
protruding 11 mm
mm to4 to 4 mmmm over mastic surface, including cleaning the
surface, removal of of debris etc. all complete. (Considering bitumen using
10.2%
10.2% asas per MORTH specification).
perMORTH specification).
16.37.1
16.37.1 25
25 mmmm thick sqm
sqm 854.15
16.37.2 40
40 mmmm thick sqm
sqm 1365.50
16.38 2.5 cm
2.5 cm thick bitumastic sheet with hot bitumen of of approved quality,
quality, using
stone chippings (60%
stone chippings with 12.5
(60% with 12.5 mm
mm nominal
nominal sizesize and 40% with
and 40% with 10
10 mm
mm
nominal
nominal size)
size)@@ 1.65 cum per
1.65 cum per 100 sqm and
100 sqm and coarse
coarse sand
sand@@ 1.65
1.65 cum
cum per
per
100 sqm
100 sqm of road surface and
and with bitumen
bitumen@@ 56 56 kg/cum ofstone
of stone chippings
and @@ 128
and 128 kg/cum ofsand overaa tack coat with hot straight run
of sand over run bitumen,
including consolidation with road roller of8
of 8 to 10 tonne etc. complete. (tack
to 10
coat to be
coat to be paid separately) :
paid separately):
16.38.1
16.38.1 With paving
With Asphalt grade
paving Asphalt grade VG
VG -- 10
10 heated
heated and then mixed
and then mixed
with solvent at the rate of 70
70 grams per
perkg ofasphalt
kg of asphalt sqm
sqm 353.65
16.38.2 With paving
With Asphalt grade
paving Asphalt grade VG
VG -- 30
30 sqm
sqm 377.05
16.38.3 With Refinery
With Refinery Modified
Modified Bitumen
Bitumen CRMB
CRMB 55 conforming to
55conforming to IRC:
IRC:
SP :: 53
SP 53 sqm
sqm 351.80

SUB HEAD:: 16.0 ROAD WORK


SUB WORK 251
Code No Description Unit Rate
16.39 44 cm
cm thick bitumastic sheet with hot bitumen of of approved quality, using
stone
stone chippings
chippings (60% with 12.5
(60% with 12.5 mm
mm nominal
nominal size and 40%
size and 40% with
with 10
10 mm
mm
nominal
nominal size)
size)@@ 2.60
2.60 cum
cum per
per 100
100 sqm and coarse
sqm and coarse sand
sand@@ 2.60
2.60 cum
cum per
per
100 sqm
100 sqm ofof road surface and
and with bitumen
bitumen@@ 56 56 kg/cum of ofstone
stone chippings
and @@ 128
and 128 kg/cum ofsand overaa tack coat with hot straight run
of sand over run bitumen,
including consolidation with road roller of8of 8 to 10 tonne etc. complete. (tack
to 10
coat to be
coat to be paid
paid separately)
separately)::
16.39.1
16.39.1 With paving
With Asphalt grade
paving Asphalt VG -- 10
grade VG 10 heated
heated and then mixed
and then mixed
with solvent at the rate of 70
70 grams per perkg
kg ofasphalt
of asphalt sqm
sqm 531.60
16.39.2 With paving
With asphalt grade
paving asphalt grade VG
VG -- 30 with no
30 with solvent
no solvent sqm
sqm 568.60
16.39.3 With Refinery
With Refinery Modified
Modified Bitumen
Bitumen CRMB
CRMB 55 conforming to
55conforming to IRC:
IRC:
SP :: 53
SP 53 sqm
sqm 528.65
SEAL COAT
16.40 Providing
Providing and
and laying seal coat
laying seal of premixed
coat of fine aggregate
premixed fine aggregate(( passing 2.36
passing 2.36
mm
mm andand retained on 180
retained on 180 micron sieve) with
micron sieve) with bitumen
bitumen using
using 128
128 kg
kg ofof
bitumen
bitumen of of grade VG -- 10
grade VG 10 bitumen
bitumen per
per cum
cum ofof fine
fine aggregate
aggregate and
and 0.60
0.60
cum
cum of fine aggregate
of fine aggregate per
per 100
100 sqm
sqm ofof road
road surface,
surface, including
including rolling
rolling and
and
finishing with
finishing with road
road roller
roller all complete.
all complete. sqm
sqm 88.55
16.41
16.41 and laying seal coat over prepared surface of road with bitumen
Providing and
heated
heated in
in bitumen
bitumen boiler fitted with
boiler fitted with the
the spray
spray set
set spraying
spraying using
using 98
98 kg of
kg of
bitumen
bitumen ofof grade VG -- 10
grade VG 10 and
and blinding surface with
blinding surface with 0.90
0.90 cum
cum ofof stone
stone
aggregate ofof 6.7 mm
mm size (Passing 11.2 mm mm sieve andand retained on on 2.36
mm sieve) per
mm sieve) per 100
100 sqm
sqm ofof road surface, including
road surface, including rolling
rolling and finishing with
and finishing with
power road roller all complete. sqm
sqm 130.85
Note: Seal coat items to be
be operated only with the prior approval of
of chief
Engineer concerned.
CONCRETE PAVEMENTS
16.42 Cement concrete 11:2:4
:2:4 (1
(1 cement :: 22 coarse sand :: 4 4 graded stone
aggregate 40 mm
aggregate 40 mm nominal
nominal size)
size) in
in pavements,
pavements, laid to required
laid to slope and
required slope and
camber
camber in
in panels as required
panels as required including
including consolidation finishing and
consolidation finishing tamping
and tamping
complete. cum
cum 7993.80
16.43 and laying design mix cement concrete of
Providing and of M-30 grade, in roads/
taxi tracks/ runways, using cement content as as per design mix, using coarse
sand and graded stone aggregate of of 40 mm nominal size in appropriate
40 mm
proportions
proportions asas per
per approved
approved&& specified
specified design criteria, providing
design criteria, dowel
providing dowel
bars with sleeve/ tie bars wherever required,
required, laying at site, spreading and and
compacting mechanically by using needle and and surface vibrators, levelling
to required
to required slope/
slope/ camber, finishing with
camber, finishing with required texture, including
required texture, steel
including steel
form work with sturdy M.S. channel sections, curing, making provision for
contraction/ expansion, construction&
construction & longitudinal joints (10 (10 mmmm widex
wide x
50 mm
50 mm deep)
deep) by groove cutting
by groove cutting machine,
machine, providing
providing and filling joints
and filling joints with
with
approved joint
approved joint filler
filler and
and sealants,
sealants, complete all as
complete all as per direction of
per direction of Engineer-
Engineer-
in-charge
in-charge (Item
(Item ofof joint
joint fillers,
fillers, sealants, dowel bars
sealants, dowel with sleeve/
bars with sleeve/ tietie bars to
bars to
be
be paid
paid separately).
separately).
Note:- Cement content considered in M-30 is is@ @ 340
340 kg/cum. Excess/ less
cement used as perperdesign separately.
design mix is payable/ recoverable separately.
16.43.1
16.43.1 Cement concrete prepared with batch mixing machine cum
cum 10529.35
16.43.2 Cement concrete manufactured in automatic batching plant
(RMC
(RMC plant)
plant) including transportation to
including transportation to site
site in transit mixer
in transit mixer cum
cum 11098.45
16.44 Extra for
for providing and
and mixing hardening compound ofapproved
of approved quality asas
per
per manufacturer’s
manufacturer's specification
specification in
in cement concrete.
cement concrete. litre 55.50

252
252 SUB HEAD:: 16.0
SUB Y6.0 ROAD
ROAO WORK
WORf
Code No Description Unit Rate
16.45 Providing and fixing
Providing and fixing pre-moulded joint filler
pre-moulded joint filler in expansion joints
in expansion joints of
of RCC
RCC
roads// CC
roads CC pavements after making thejoints
the joints dust free with high pressure
air jet cleaners, all complete as per per direction of the
the Engineer-in-Charge. percm
per cm
(Pre-moulded joint fillers
(Pre-moulded joint fillers shall
shall be
be made of bitumen hot
made ofbitumen sealing compound
hot sealing compound depth per
impregnated fibre board
impregnated fibre board having
having impregnation
impregnation more than 35%,
more than 35%, conforming
conforming cm
cm width
to IS:1838
to for fibre board
IS:1838 forfibre board andand IS:
IS: 1834 for hot sealing bitumen
1834 forhotsealing bitumen compound
compound per metre
grade A.)
grade A.) length 5.30
16.46 Providing
Providing and filling in
and filling in position
position rubberized
rubberized bitumen
bitumen hot
hot sealing
sealing compound
compound
forsealing
for sealing of expansion joints in roads roads// pavements all complete as per
direction of the
the Engineer-in-Charge.
16.46.1
16.46.1 Providing
Providing and and filling
filling in
in position
position rubberized
rubberized bitumen
bitumen hot sealing
hotsealing per cm
cm
compound for for sealing of expansion joints in roads// pavements depth per
all complete as per per direction of the
the Engineer-in-Charge. cm width
cm
per metre
length 8.65
PAINTING AREA/RUNWAY MARKING
16.47 Painting runway/taxi track/apron marking with adequate nos of of coats to
give
give uniform finish with
uniform finish with road
road marking
marking paint of superior
paint of superior make as approved
make as approved
by the
the Engineer-in-charge, including cleaning the surface of ail dirt,
dirt, scales,
oil, grease and
and other foreign material etc. and
and lining out
out complete.
16.47.1
16.47.1 New work (Two
New work or more
(Two or more coats)
coats) sqm
sqm 188.20
16.47.2 Old work (One
Old work (One or more coats)
ormore coats) sqm
sqm 120.80
16.48 Painting road surface marking with adequate nos of of coats to give uniform
finish with
finish with ready
ready mixed
mixed road
road marking
marking paint
paint conforming
conforming toto IS
IS:: 164, on
164, on
bituminous surface in white/yellow shade, including cleaning the surface
of all dirt, scales, oil, grease and
and foreign material etc. complete.
16.48.1
16.48.1 New work (Two
New work or more
(Two or more coats)
coats) sqm
sqm 288.90
16.48.2 Old work (One
Old work (One or more coats)
ormore coats) sqm
sqm 189.85
MISCELLANEOUS
16.49 Making bell mouth opening/ entrance of of size 100x50x50 cm cm fordrainage
for drainage
pipe under footpath, including providing cement concrete1 :3:6 (1
concrete 1:3:6 (1 cement:
cement :
3 3 coarse
coarse sand
sand::6 6 graded
graded stone
stone aggregate
aggregate 20
20 mm
mm nominal
nominal size) for shape
size) for shape
of
of bell
bell mouth,
mouth, including
including plastering
plastering providing and fixing
providing and fixing precast
precast R.C.C./
R.C.C./
S.F.R.C. slab including plastering with cement mortar
mortar11:3:3 (1
(1 cement
cement::3 3
fine sand)
fine sand) of
of66 mm thickness on
mm thickness on exposed
exposed surface
surface of the slab&
of the slab & bell
bell mouth
mouth
including centring, shuttering&
shuttering & neat cement punning inside the the bell mouth
etc. all complete. each 3050.40
16.50 Providing and fixing
Providing and fixing Glow
Glow studs of size
studs of size 100x20
100x20 mmmm made of heavy duty
made ofheavy duty
body
body shall
shall be
be moulded
moulded ASAASA (Acrylic
(Acrylic styrene Acryloretrite ) or
styrene Acryloretrite) or HIP
HIP (High
(High
impact
impact polystyrene)
polystyrene) oror ABS
ABS having
having electronically welded micro-
electronically welded micro- prismatic
prismatic
lens with abrasion resistant coating as as approved by Engineer in charge.
The
The glow stud shall supporta
support a load of 13635 kg tested in accordance
with ASTM
with ASTM D4280.
D4280. TheThe slope
slope of
of retro-
retro- reflective
reflective surface
surface shall
shall be
be 35
35 (+/-
(+/-
5) degress to
5) degress to base
base .The
.The reflective
reflective panels
panels onon both sides with
both sides with at
at least
least 12 12
cm
cm ofof reflective area up
reflective area each side.
up each side. The
The luminance
luminance intensity should be
intensity should be
as
as per the specification
per the and shall
specification and shall be tested as
be tested as described
described in ASTM I:
in ASTM I: 809
809
as
as recommended
recommended in in BS:
BS: 873
873 part
part44:: 1973. The studs
1973. The studs shall
shall be fixed to
be fixed to
the
the Road surface using the adhesive conforming to as per
to IS, as per procedure
recommended by by the
the manufacturer complete and and as per direction of
Engineer-in-charge. each 206.30

sua HeAD
SUB HEAD:: 16.0
16.0 RoAD woRK
ROAD WORK 253
Code No Description Unit Rate
16.51
16.51 Preparation
Preparation of of sub-base
sub-base road road pavement
pavement with with commercial
commercial dry dry lime
lime (slaked),
(slaked),
fly ash
fly ash stabilised
stabilised soil with a mix
soil witha mix ofof 3%
3% lime,
lime, 12%
12% flyfly ash
ash andand 85%
85% local
local
suitable
suitable soilsoil by weight, so
by weight, so as
as toto achieve
achieve minimum
minimum field field C.B.R.
C.B.R. of 20,
of 20,
including mixing, rolling with road roller curing etc. all complete.
16.51.1
16.51.1 Minimum thickness 15 15 cm
cm cum
cum 1514.40
16.52 Providing
Providing and fixing precast
and fixing precast lime fly ash
lime fly ash concrete
concrete blocks
blocks 1:2:3:6
1:2:3:6 (1(1 lime:
lime:
2 2 fly
fly ash
ash ::3 3 coarse
coarse sand:
sand :6 6 graded
graded stonestone aggregate
aggregate 20 20 mm mm nominal
nominal
size),
size), including finishing with
including finishing with 10
10 mm thick cement
mm thick cement mortar
mortar 1:31:3 (1 cement : 3
(1 cement:3
coarse sand) in
coarse sand) foot paths,
in foot paths, including
including preparation
preparation of of sub
sub grade
grade witha
with a hand
hand
rammer,
rammer, laying
laying 10 10 mm thick leveling
mm thick course of
leveling course of fine
fine sand
sand (jamuna sand)
(jamuna sand)
and filling the
and filling the joints
joints with
with fine
fine sand.
sand. cum
cum 13719.05
16.53 Providing
Providing and and fixing
fixing concertina
concertina coil fencing with
coil fencing with punched
punched tape tape concertina
concertina
coil 600 mm
coil 600 mm dia dia 10 10 metre openable length
metre openable length(( total
total length
length 9090 m),
m), having
having 5050
nos rounds per66 metre length, upto
nos upto33 m m height of wall with existing angle
iron ‘Y’ shaped placed 2.4m or or 3.00 m m apart andand with9
with 9 horizontal R.B.T.
reinforced barbed wire, stud tied with G.I. staples and and G.I. clips to retain
horizontal, including necessary bolts or G.I. barbed wire tied to angle iron,
horizontal,
all complete as per per direction of Engineer-in-charge, with reinforced barbed
tape(R.B.T.) / Spring
tape(R.B.T.)/ core (2.5
Spring core (2.5 mm thick) wire
mm thick) wire ofof high tensile strength
high tensile strength ofof
165
165 kg/ sq. mm
kg/ sq. mm with with tape
tape (0.52
(0.52 mm thick) and
mm thick) and weight
weight 43.478
43.478 gm/ gm/ metre
metre
(cost
(cost ofof M.S.
M.S. angle,
angle, C.C.C.C. blocks shall be
blocks shall be paid separately)
paid separately) metre 375.80
16.54 Providing and and laying Dense Graded Bituminous Macadam using crushed
stone aggregates of
stone aggregates of specified
specified grading,
grading, premixed
premixed with with bituminous
bituminous binder
binder
and filler, transporting
and filler, transporting the
the hot
hot mix to work
mix to work site
site by tippers, laying
by tippers, with paver
laying with paver
finisher equiped
finisher equiped with
with electronic
electronic sensor
sensor toto the
the required grade, level
required grade, and
level and
alignment and and rolling with smooth wheeled, vibratory and and tandem rollers
as
as per specifications to
per specifications to achieve
achieve the
the desired
desired compaction
compaction and and density,
density,
complete
complete as as per
per specificatons and directions
specificatons and directions of
of Engineer-in-Charge.
Engineer-in-Charge.
16.54.1
16.54.1 50 to 100
50 100 mmmm average compacted thickness with bitumen of of
grade VG-30@
grade VG-30 @ 5% 5% (percentage
(percentage by weight of
by weight total mix)
of total and
mix) and
lime filler@ @ 2%
lime filler 2% (percentage
(percentage by weight ofAggregate)
by weight of Aggregate) prepared
prepared
in Batch Type Hot Hot Mix
Mix Plant of 100-120 TPH
TPH capacity. cum
cum 11129.55
16.54.2 50 to 100
50 100 mmmm average compacted thickness with bitumen of of
grade VG-30 @ 5%
grade VG-30@ 5% (percentage
(percentage by weight of
by weight total mix)
of total mix) and
and
lime filler@ @ 2%
lime filler 2% (percentage
(percentage by weight ofAggregate)
by weight of Aggregate) prepared
prepared
in Drum Type Hot Hot Mix
Mix Plant of 60-90 TPH
TPH capacity. cum
cum 11032.20
16.55 Providing and
and laying bituminous macadam using crushed stone aggregates
of specified grading
of specified grading premixed with bituminous
premixed with bituminous binder, transported to
binder, transported to site
site
by tippers, laid
by tippers, over a previously
laid overa previously prepared
prepared surface with paver
surface with finisher
paver finisher
equiped with electronic sensor to to the
the required grade, level and
and alignment
and rolling with smooth wheeled, vibratory and
and and tandem rollers as per
as per
specifications to achieve
specifications to achieve the
the desired
desired compaction
compaction and density, complete
and density, complete as
as
per specificatons and
per specificatons and directions of Engineer-in-Charge.
directions of Engineer-in-Charge.
16.55.1
16.55.1 50 to 100
50 100 mm
mm average compacted thickness with bitumen
of grade VG-30@
of grade VG-30 @ 3.50%3.50% (percentage
(percentage by weight of
by weight of total
total
mix)
mix) prepared
prepared inin Batch Type Hot
Batch Type Hot Mix
Mix Plant of 100-120
Plant of TPH
100-120 TPH
capacity. cum
cum 8505.65
16.55.2 50 to 100
50 100 mm
mm average compacted thickness with bitumen of of
grade VG-30 @ 3.50%
grade VG-30@ 3.50% (percentage
(percentage by weight of
by weight total mix)
of total mix)
prepared in Drum Type Hot Hot Mix
Mix Plant of 60-90 TPH
TPH capacity. cum
cum 8413.00

254
254 sua HEAD
SUB HeAD:: 16.0
Ys.o ROAD
RodO WORK
woRf
Code No Description Unit Rate
16.56 Providing and and laying semi- dense Bituminous concrete using crushed
stone aggregates of
stone aggregates of specified
specified grading,
grading, premixed with bituminous
premixed with bituminous binder
binder
and filler, transporting
and filler, transporting the
the hot
hot mix to work
mix to work site
site by tippers, laying
by tippers, with paver
laying with paver
finisher equiped
finisher equiped with
with electronic
electronic sensor
sensor to
to the
the required grade, level
required grade, and
level and
alignment and and rolling with smooth wheeled, vibratory and and tandem rollers to
achieve
achieve thethe desired
desired compaction
compaction andand density
density as
as per specification, complete
per specification, complete
and as per
and per directions of Engineer-in-Charge.
16.56.1
16.56.1 25 mm
25 mm compacted thickness with
compacted thickness with bitumen
bitumen of grade VG-30@
of grade VG-30 @
5%
5% (percentage
(percentage by weight of
by weight of total
total mix)
mix) and
and lime filler @ 2%
lime filler@ 2%
(percentage
(percentage by weight of
by weight Aggregate) prepared
ofAggregate) prepared in in Batch
Batch Type Type
Hot Mix
Hot Mix Plant of 100-120 TPH capacity.
TPH capacity. sqm
sqm 277.70
16.56.2 25 mm
25 mm compacted thickness with
compacted thickness with bitumen
bitumen of grade VG-30@
of grade VG-30 @
5%
5% (percentage
(percentage by weight of
by weight of total
total mix)
mix) and
and lime filler @ 2%
lime filler@ 2%
(percentage
(percentage by weight of
by weight of Aggregate)
Aggregate) prepared
prepared in in Drum
Drum Type Type
Hot Mix
Hot Mix Plant of 60-90 TPH capacity.
TPH capacity. sqm
sqm 275.30
16.57 Providing and
and laying Bituminous concrete using crushed stone aggregates
of specified grading,
ofspecified grading, premixed
premixed withwith bituminous
bituminous binder and filler,
binder and filler, transporting
transporting
the hot
the hot mix to work
mix to work site
site by tippers, laying
by tippers, with paver
laying with finisher equiped
paver finisher equiped with with
electronic sensor to to the required grade, level and and alignment and and rolling
with smooth wheeled, vibratory and and tandem rollers to achieve the desired
compaction and density
compaction and density as
as per
per specification,
specification, complete
complete andand asas per directions
perdirections
of Engineer-in-Charge.
16.57.1
16.57.1 40/50 mm
40/50 compacted thickness
mm compacted thickness with
with bitumen
bitumen of of grade
grade VG-30VG-30
@@ 5.5%
5.5% (percentage
(percentage by weight of
by weight of total
total mix)
mix) and
and lime filler @
lime filler@
3%
3% (percentage
(percentage by weight of
by weight Aggregate) prepared
of Aggregate) prepared in in Batch
Batch
Type Hot
Hot Mix
Mix Plant of 100-120 TPH capacity.
TPH capacity. cum
cum 12126.20
16.57.2 40/50 mm
40/50 compacted thickness
mm compacted thickness with
with bitumen
bitumen ofof grade
grade VG-
VG-
30
30@@ 5.5%
5.5% (percentage
(percentage by weight of
by weight of total
total mix) and lime
mix) and filler
lime filler
@ @ 3%
3% (percentage
(percentage by weight of
by weight Aggregate) and
ofAggregate) waste plastic
and waste plastic
additive
additive@@ 8%
8% (percentage
(percentage by weight of
by weight of bitumen)
bitumen) prepared
prepared in in
Batch Type Hot
Hot Mix
Mix Plant of 100-
100-120
120 TPH
TPH capacity. cum
cum 12708.75
16.57.3 40/50 mm
mm compacted thickness with bitumen of of grade PMB-
40@@ 5.5%
40 5.5% (percentage
(percentage by weight of
by weight of total
total mix) and lime
mix) and filler
lime filler
@ @ 3%
3% (percentage
(percentage by weight ofAggregate)
by weight of Aggregate) prepared
prepared in
in Batch
Batch
Type Hot
Hot Mix
Mix Plant of 100-120 TPH capacity.
TPH capacity. cum
cum 11204.10
16.57.4 40/50 mm
mm compacted thickness with bitumen ofgrade
of grade CRMB-
60
60@@ 5.5%
5.5% (percentage
(percentage by weight of
by weight of total
total mix) and lime
mix) and filler
lime filler
@ @ 3%
3% (percentage
(percentage by weight ofAggregate)
by weight of Aggregate) prepared
prepared in
in Batch
Batch
Type Hot
Hot Mix
Mix Plant of 100-120 TPH capacity.
TPH capacity. cum
cum 10660.30
16.57.5 40/50 mm
40/50 compacted thickness
mm compacted thickness with
with bitumen
bitumen ofof grade
grade VG-
VG-
30
30@@ 5.5%
5.5% (percentage
(percentage by weight of
by weight of total
total mix) and lime
mix) and filler
lime filler
@ @ 3%
3% (percentage
(percentage by weight ofAggregate)
by weight of Aggregate) prepared
prepared in drum
in drum
Type Hot
Hot Mix
Mix Plant of 60-90 TPH capacity.
TPH capacity. cum
cum 12026.80
16.57.6 40/50 mm
40/50 compacted thickness
mm compacted thickness with
with bitumen
bitumen ofof grade
grade VG-
VG-
30
30@@ 5.5%
5.5% (percentage
(percentage by weight of
by weight of total
total mix) and lime
mix) and filler
lime filler
@ @ 3%
3% (percentage
(percentage by weight of
by weight Aggregate) and
ofAggregate) waste plastic
and waste plastic
additive
additive@@ 8%
8% (percentage
(percentage by weight of
by weight of bitumen)
bitumen) prepared
prepared in in
drum Type Hot
Hot Mix
Mix Plant of 60-90 TPH
TPH capacity. cum
cum 12609.30
16.57.7 40/50 mm
mm compacted thickness with bitumen of of grade PMB-
40@@ 5.5%
40 5.5% (percentage
(percentage by weight of
by weight of total
total mix) and lime
mix) and filler
lime filler
@ @ 3%
3% (percentage
(percentage by weight ofAggregate)
by weight of Aggregate) prepared
prepared in drum
in drum
Type Hot
Hot Mix
Mix Plant of 60-90 TPH capacity.
TPH capacity. cum
cum 11104.65

SUB HEAD:: 16.0 ROAD WORK


SUB WORK 255
255
Code No Description Unit Rate
16.57.8 40/50 mm mm compacted thickness with bitumen ofgrade of grade CRMB-
60
60@@ 5.5% 5.5% (percentage
(percentage by weight of
by weight of total
total mix) and lime
mix) and filler
lime filler
@ @ 3% 3% (percentage
(percentage by weight ofAggregate)
by weight of Aggregate) prepared
prepared in in Drum
Drum
Type Hot Hot Mix
Mix Plant of 60-90 TPH capacity.
TPH capacity. cum
cum 10560.85
16.59 Manufacturing, supplying and
Manufacturing, supplying and fixing
fixing retro
retro reflective sign boards
reflective sign boards made
made up up
of
of22 mm
mm thick aluminium sheet, face to be be fully covered with high intensity
encapsulated
encapsulated type type heatheat activated
activated retroretro reflective sheeting conforming
reflective sheeting conforming
to type
to type -- IV
IV ofof ASTM-D
ASTM-D 4956-01
4956-01 in in blue and silver
blue and white or
silver white other colour
or other colour
combination
combination including subject matter,
including subject matter, message
message (bi-lingual), symbols and
(bi-lingual), symbols and
borders etc. as as perper IRC
IRC ;; 67:2001, pasted on on substrate by by an
an adhesive
backing which shall be be activated by by applying heat andand pressure conforming
to class
to class -2
-2 ofof ASTM-D-4956-01
ASTM-D-4956-01 and fixing the
and fixing the same with suitable
same with suitable sized
sized
aluminium alloy rivets rivets@ @ 2020 cmcm c/cc/c to back support frame of of M.S. angle
iron of size 25x25x3 mm mm along with theft resistant measures, mounted
and fixed with2
and fixed with 2 Nos. Nos. M.S. angles of
M.S. angles size 35x35x5
of size 35x35x5 mmmm to toaa vertical
vertical post
post
made up up toM.S.
to M.S. Tee Tee section ISMT 50x50x6 mm mm welded with base plate
of size 100x100x5 mm mm at at the
the bottom end and including making holes in
end and
pipes,
pipes, angles flats, providing
angles flats, providing&& fixing
fixing M.S.
M.S. message
message plate
plate ofof required size,
required size,
steel work tobe
to be painted with two two or more coats of of synthetic enamel paint
of required shade and ofapproved
of approved brandbrand&& manufacture over priming coat
of zinc chromate yellow primer (vertical MS-Tee support to be
of be painted in
black
black and white colours).Backside
and white colours).Backside of of aluminium sheet to
aluminium sheet to bebe painted with
painted with
two
two or more coats of of epoxy paint over and and including appropriate priming
coat
coat including
including allall leads
leads and
and lifts etc. complete
lifts etc. complete as as per drawing , specification
per drawing, specification
and direction of Engineer-in-charge.
and
16.59.1
16.59.1 Mandatory/ Regulatory sign boards of
of 900
900 mm
mm diametre with
support length of 3750 mm
mm each 7183.35
16.59.2 Cautionary /warning sign boards of of equilateral triangular
shape having each side of 900 900 mmmm with support length of
mm
3650 mm each 5559.75
16.60 Manufacturing, supplying and
Manufacturing, supplying fixing retro
and fixing retro reflective overhead signage
reflective overhead signage
boards made up up ofof22 mmmm thick aluminium sheet, face to be be fully
covered with high intensity and and encapsulated lens type heat activated
retro
retro reflective
reflective sheeting conforming to
sheeting conforming to type
type -- III
III ofof ASTM-D-4956-01
ASTM-D-4956-01 as as
approved by Engineer-in-charge, letters, borders etc. as per IRC
as per IRC :: 67-2001
67-2001
in silver white with blue colour back ground and and with high intensity grade,
pasted on on substrate by
by pressure sensitive adhesive backing which shall be be
activated by by applying pressure conforming to to class II of of ASTM-D-4956-01
ASTM-D-4956-01
and fixing the
and fixing the same to the plate of
same totheplate of structural frame work
structural frame work by by means
means of of
alloys, rivets or
suitable sized aluminium alloys, bolts&& nuts
or bolts nuts@@ 300 300 mmmm centre to
centre all along the periphery as as well asas in two
two vertical rows along with theft
resistant measures, including the the cost of painting with two two or more coats
of epoxy paint in grey colour on
of on the back side of aluminium sheet including
appropriate
appropriate priming coat. The
priming coat. The rate
rate includes
includes the the cost
cost ofof rounding
rounding offoff the
the
corners,
corners, lowering down thestructural
lowering down the structural frame
frame work
work from
from thegantry,
the gantry, fixing
fixing and
and
erecting
erecting thethe same
same inin position
position all
all complete
complete as as per drawings, specification
per drawings, specification
and direction of the
and the engineer-in-charge.(Structural frame work including
M.S. plate to be be provided separately.
separately. Rectangular area of of the sheet only
shall
shall be
be measured for payment).
measured forpayment).
16.60.1
16.60.1 Overhead informatory road signage sqm
sqm 5879.90

256
256 sua HEAD
SUB HeAD:: 16.0
Ys.o ROAD
RodO WORK
woRf
Code No Description Unit Rate
16.61
16.61 Providing
Providing Retro-reflective
Retro-reflective regulatory
regulatory sign
sign board
board ofof size
size 900
900 mmmm dia
dia metre
metre
made out
out of
of22 mm
mm thick aluminium sheet, face to be fully covered with high
to be
intensity encapsulated lens
intensity encapsulated type retro
lens type -reflective sheeting
retro -reflective sheeting asas approved
approved by by
Engineer-in-charge.. Letter,
Engineer-in-charge Letter, symbols, borders etc. will be be as
as per
per IRC
IRC - 67
67
with required colour scheme on the the boards and and with the high intensity
grade A. The
The aluminium sheet to be riveted to M.S. frame of
to be of angle iron
of
of size 40x40x4 mm.
size 40x40x4 The boards
mm. The will be
boards will fixed to1
be fixed to 1 No.
No. 50x50
50x50 mm mm square
square
post made of ofM.S.
M.S. angle 50x50x4 mm,mm, 44 m m long welded totheframe
to the frame with
adequate anti-theft arrangement .Sheet work to to be painted with two two or
more
more coats of synthetic
coats of synthetic enamel
enamel paint over an
paint over an under coat (primer)
under coat and back
(primer) and back
side of aluminium sheet to to be painted with two two or more coats of of epoxy
paint including appropriate priming coat complete in all respects as as per
direction of Engineer-in-charge. each 8154.35
16.62 Providing and applying
Providing and 2.5 mm
applying 2.5 thick road
mm thick road marking
marking strips
strips (retro-
(retro- reflective)
reflective)
of
of specified shade/ colour
specified shade/ colour using
using hot thermoplastic material
hot thermoplastic material by fully/ semi
by fully/ semi
automatic thermoplastic paint
automatic thermoplastic applicator machine
paint applicator fitted with
machine fitted with profile
profile shoe,
shoe,
glass
glass beads dispenser, propane
beads dispenser, tank heater
propane tank heater and
and profile
profile shoe
shoe heater,
heater,
by experienced operator on
driven by on road surface including cost of material,
material,
labour, T&P, cleaning the road surface of all dirt,
dirt, seals, oil, grease and and
foreign material etc. complete as per direction of Engineer-in-charge and and
accordance with applicable
accordance with applicable specifications.
specifications. sqm
sqm 747.80
16.63 Providing, laying and
Providing, and making kerb channel 30 30 cm
cm wide and 50 mmmm thick
with cement concrete 11:3:6:3:6 (1
(1 cement: 33 coarse sand:6 graded stone
aggregate 20 mm
aggregate 20 mm nominal
nominal size) over 75
size) over 75 mm
mm bed of dry
bed of dry brick
brick ballast 40
ballast 40
mm
mm nominal
nominal size, well rammed
size, well rammed and and consolidated
consolidated and
and grouted with fine
grouted with fine
sand,
sand, including finishing the
including finishing the top
top smooth
smooth etc.
etc. complete and as
complete and as per
per direction
direction
of Engineer-in-charge. sqm
sqm 558.30
16.64 and laying 75
Providing and 75 mm
mm thick compacted bed ofdrybrick
of dry brick aggregate of
of
40 mm thick nominal size including spreading,
40 mm spreading, well ramming, consolidating
and
and grouting with jamuna
grouting with jamuna sand,
sand, including finishing smooth
including finishing smooth etc.
etc. complete
complete
per direction of Engineer-in-charge.
as per sqm
sqm 199.35
16.65 Providing and fixing
Providing and fixing post
post delineators
delineators made of ABS round
made ofABS round body fitted with
body fitted with
22 nos
nos 100
100 mm
mm dia dia high
high reflective
reflective reflectors
reflectors andand mounted
mounted on on MS
MS pipe
pipe ofof 65
65
mm dia duly powder coated anti-rust and
mm and anti theft steel to be be installed asas
per direction of Engineer-in-charge.
per each 904.20
16.66 Excavating holes upto 0.10 cum, including getting out out the
the excavated soil,
then returning the as deported in layers not exceeding 20
the soil as cm in depth,
20 cm
including consolidating and and deposited layer by by ramming watering etc.,
disposing of surplus excavated soil as as directed with in ina a lead of 5050 mm
mm
and lift upto 1.5
and 1.5 m.
m.
16.66.1
16.66.1 All kind of soil each 27.50
16.67 Providing and fixing
Providing and fixing at
at or
or near
near ground
ground level factory made
level factory made RCCRCC pavement
pavement
slab of M-30 grade ofsize
of size 450x450x50 mm, mm, including reinforcement with6 with 6
mm dia M.S. bars44 nos
mm nos on
on each side, including setting in position in footpath
to the required level and and line overa
over a bed bed ofof 20
20 mm
mm average thick cement
mortar
mortar 1:5
1:5 (1 cement : 5 coarse
(1 cement:5 coarse sand),
sand), having joint thickness
having joint thickness not
not more than
more than
55 mm
mm except
except on curve, including
on curve, filling of
including filling joints with
of joints with same cement mortar
same cement mortar
and making grooves etc. complete as per
and per direction of Engineer-in-charge. sqm
sqm 1600.55
16.68 and laying 60
Providing and 60 mm mm thick faciory made cement concrete
interlocking paver block of
interlocking ofMM -30 grade made by by block making machine
with strong vibratory compaction,
compaction, of of approved size, design&
design & shape, laid
and pattern over and
in required colour and and including 50
50 mm
mm thick compacted
bed of coarse sand,
bed ofcoarse sand, filling
filling the
the joints
joints with
with line sand etc.
line sand etc. all
all complete
complete as
as per
per
the direction of Engineer-in-charge. sqm
sqm 972.00

sua HeAD
SUB HEAD:: 16.0
16.0 RoAD woRK
ROAD WORK 257
Code No Description Unit Rate
16.69 and laying at or near ground level factory made kerb stone of
Providing and of
M-25 grade cement concrete in position to the the required line, level and
and
curvature, jointed with
curvature, jointed with cement
cement mortar
mortar11:3
:3 (1
(1 cement:
cement: 33 coarse
coarse sand),
sand),
including making joints with or without grooves (thickness of joints except
at sharp curve
at sharp curve shall
shall not to more
not to than 5 mm),
more than5 mm), including
including making drainage
making drainage
opening wherever required complete etc. as per direction of Engineer-
as per
in-charge
in-charge (length of finished
(length of finished kerb
kerb edging shall be
edging shall be measured
measured toto calculate
calculate
volume for
volume for payment).
payment). (Precast
(Precast C.C.
C.C. kerb
kerb stone shall be
stone shall approved by
be approved by
Engineer-in-charge).
Engineer-in-charge). cum
cum 10117.60
16.70 Providing and fixing
Providing and fixing G.I.
G.I. chain
chain link fabric fencing
link fabric fencing of
of required width in
required width in mesh
mesh
mm including strengthening with2
size 50x50 mm mm dia wire or nuts, bolts
with 2 mm
and washers as required complete as per the
and the direction of Engineer-in-
charge.
16.70.1
16.70.1 ofG.I.
Made of G.I. wire of dia44 mm
mm sqm
sqm 1017.80
16.70.2 Made of G.I. wire
Made ofG.I. wire of dia. 4 mm,
of dia.4 mm, PVC
PVC coated to achieve
coated to achieve outer
outer
dia not less than5 mm in required colour and
than 5 mm and shade sqm
sqm 1067.10
16.71
16.71 Providing and fixing
Providing and fixing G.I.
G.I. chain
chain link fabric fencing
link fabric fencing of
of required width in
required width in mesh
mesh
size 25x25 mmmm made of ofG.I.
G.I. wire of dia3 mm including strengthening with
dia 3 mm
22 mm
mm dia wire or nuts, bolts and
and washers as required complete as per the
direction of Engineer-in-charge. sqm
sqm 1149.25
16.72 Supplying
Supplying and
and stacking of hard
stacking of stone (for
hard stone (for stone
stone pitching) 22.5 cm
pitching) 22.5 cm thick
thick at
at
site. cum
cum 995.85
16.73 Dry
Dry stone
stone pitching 22.5 cm
pitching 22.5 thick laid
cm thick laid in
in courses
courses and
and required
required profile with
profile with
hammer dressed stones having no no side less than 15 cm,
cm, with minimum
depth of
of 20
20 cm
cm including preparing the bedding surface etc. all complete.
(Payment for Stone to
(Payment forStone to be
be made
made separately).
separately). sqm
sqm 659.05
16.74 75
75 mm thick back
mm thick filling for
back filling for pitching
pitching including supplying of
including supplying of required
required
materials and
and consolidation etc. complete with:
with :
16.74.1
16.74.1 Moorum sqm
sqm 76.30
16.74.2 Stone aggregate 20 mm nominal size
20 mm sqm
sqm 175.00
16.74.3 Stone aggregate 40 mm nominal size
40 mm sqm
sqm 172.35
16.75 Providing and
and laying C.C. pavement ofmixof mix M-25 with ready mixed concrete
from batching
from batching plant. The ready
plant. The ready mixed concrete shall
mixed concrete shall bebe laid
laid and finished
and finished
with screed
with screed board vibrator , vacuum
board vibrator, vacuum dewatering
dewatering process
process and finally finished
and finally finished
by floating, brooming
by floating, with wire
brooming with wire brush
brush etc.
etc. complete
complete as as per specifications
per specifications
and directions of Engineer-in-charge. (The panel shuttering work shall be
and be
paid for separately).
paid forseparately).
(Note:- Cement content considered in this item is is@ @ 330
330 kg/cum. Excess/
less cement used
less cement used asas per design mix
perdesign mix is
is payable/
payable/ recoverable separately).
recoverable separately). cum
cum 9823.80
16.76 Deduct forusing
for using of M-20 grade concrete instead of M-25 grade concrete
pavement.
in C.C. pavement. cum
cum 203.80
16.77 Scarifying the
the existing bituminous road surface toa to a depth of of 50 mm
50 mm
and disposal
and disposal ofof scarified
scarified material within all
material within all lifts
lifts and
and lead
lead upto
upto 1km
1km (by
(by
mechanical
mechanical means).
means). sqm
sqm 7.00
16.78 Construction of granular sub-base by providing close graded Material
Construction
conforming to
conforming to specifications,
specifications, mixing
mixing in
ina a mechanical
mechanical mix mix plant at OMC,
plant at OMC,
carriage of mixed material by by tippers to work site, for leads&& lifts,
for all leads lifts,
spreading in
spreading in uniform
uniform layers of specified
layers of thickness with
specified thickness with motor grader on
motor grader on
prepared surface and and compacting with vibratory power roller to to achieve the
desired density,
desired complete as
density, complete as per specifications and
per specifications and directions
directions of of Engineer-
Engineer-
in-Charge.

258
258 sua HEAD
SUB HeAD:: 16.0
Ys.o ROAD
RodO WORK
woRf
Code No Description Unit Rate
16.78.1
16.78.1 With material conforming to mm to
to Grade-I (size range 75 mm to
0.075
0.075 mm)
mm) having
having CBR Value-30
CBR Value-30 cum
cum 2784.00
16.78.2 With material conforming to 53 mm
to Grade-II (size range 53 mm to
to
0.075
0.075 mm
mm )) having
having CBR Value-25
CBR Value-25 cum
cum 2924.85
16.78.3 With material conforming toto Grade-III (size range 26.5 mm mm toto
0.075
0.075 mm
mm )) having
having CBR Value-20
CBR Value-20 cum
cum 2808.55
16.79 Providing, laying, spreading and
Providing, and compacting graded stone aggregate (size
range
range 5353 mm
mm toto 0.075
0.075 mm
mm )) to
to wet
wet mix
mix macadam
macadam (WMM)
(WMM) specification
specification
including premixing the material with water at at OMC
OMC in forfor all leads
leads&& lifts,
laying
laying in
in uniform
uniform layers with mechanical
layers with mechanical paver finisher in
paver finisher sub- base
in sub- base// base
base
course onon well prepared surface andand compacting with vibratory roller of of
8 8 to 10 tonne capacity to achievethe desired density, complete as per
to 10
specifications and directions
specifications and directions of
of Engineer-in-Charge.
Engineer-in-Charge. cum
cum 2914.30
16.80 Construction of dry lean cement concrete sub sub base overa
over a prepared sub-
grade with coarse
grade with coarse and fine aggregate
and fine conforming to
aggregate conforming to IS:383, the size
IS:383, the size of
of
coarse aggregate not not exceeding 25 mm, aggregate cement ratio not
25 mm, not to
exceed
exceed 15:1,
15:1, aggregate gradation after
aggregate gradation after blending to be
blending to be as
as per specifications,
per specifications,
cement content not to be be less than 150
150 Kg/cum, optimum moisture content
to be
be determined during trial length construction,
construction, concrete strength not to
be less than 10 Mpa
be Mpa at at77 days, mixed in ina a batching plant, transported
transported to
site, for leads&& lifts, laid witha
for all leads with a mechanical paver, compacting with 8-10
tonne vibratory
tonne vibratory roller, finishing and
roller, finishing and curing
curing etc. complete as
etc. complete as per direction of
per direction of
Engineer-in- charge. cum
cum 4148.65
16.81
16.81 Providing andand erecting 2.00 metre high temporary barricading at site; each
panel ofof size 2.50 mm x2.00 m m made of40x40x6
of 40x40x6 mm mm angle iron or 50x50x3
mm hollow MS
mm MS tube posts/horizontal members/bracings covered with 1.63
mm thick MS
mm thick MS sheet. The sheet
sheet. The sheet shall
shall be fixed with
be fixed with 30x5
30x5 mmmm MS flat by
MS flat by
suitable welding/riveting. The The panels shall be be made soso that gap
gap of 50cm
above theground
the ground is available making overall height as m. MS
as 2.5 m. MS channel
ISLC 75 75@@ 5.70 kg/m, 50 50 cm
cm long shall be be provided atat the bottom having
oval shaped holes of size 50x25 mm mm at at both ends with 50 50 cm
cm long MS MS
angle 40x40x6 mm
angle 40x40x6 mm bracing.
bracing. Suitable
Suitable arrangement
arrangement shall
shall be
be made to fix the
made tofix the
barricading to avoid from overturning
overturning by by providing 250 mm long expansion
250 mm
fasteners at both ends. TheThe work shall be be executed as per
perdrawing/direction
drawing/direction
of Engineer-in-Charge which includes writing and and painting, arrangement
for traffic diversion
fortraffic diversion such
such asas traffic
traffic signals
signals during
during construction
construction at at site
site for
for
day
day and
and night,
night, glow
glow lamps,
lamps, reflective
reflective signs,
signs, marking, flags, caution
marking, flags, tape
caution tape
as directed by by the
the Engineer-in-Charge. The barricading provided shall be
The barricading be
retained in position at site continuously including shifting of barricading
from one
one location to another location as as many times as as required during the
execution of ofthe
the entire work till its completion. Rate include its maintenance
fordamages, painting, all incidentals,
for damages, painting, incidentals, labour materials,
materials, equipments and and
works required to execute the job. The barricading shall not
The barricading not be
be removed
without prior approval of of Engineer-in-Charge.
One time payment shall be
(Note :- One be made for barricading from
for providing barricading
start of work till completion of
of work including shifting. The
The barricading
provided shall remain toto be the property of the contractor on
on completion
of the work).
of the work). metre 3439.50
16.82 Taking out existing kerb stones of
of all types from footpath/ central verge,
including removal of
of mortar etc., disposal of unserviceable material to
the
the dumping ground, for
for which payment shall bebe made separately andand
stacking of serviceable material within 50
50 metre lead as
as per direction of
Engineer-in-Charge. metre 39.35

sua HeAD
SUB HEAD:: 16.0
16.0 RoAD woRK
ROAD WORK 259
259
Code No Description Unit Rate
16.83 Taking out existing CC
CC interlocking
interlocking paver blocks from footpath/ central
verge, including removal of
ofrubbish
rubbish etc., disposal of unserviceable material
to the dumping ground, forwhich
for which payment shall be be made separately and
and
stacking of serviceable material within 5050 metre lead as
as per direction of
Engineer-in-Charge. sqm
sqm 131.75
16.84 Laying old
old cement cocrete interlocking paver blocks of any any design/ shape
line, level, curvature, colour and
laid in required line, and pattern over and and including
50
50 mm thick compacted
mm thick compacted bed of coarse sand,
bed ofcoarse filling the
sand, filling the joints
joints with
with fine
fine sand
sand
etc. all complete as perper the
the direction of Engineer-in-charge. (Old CC CC paver
blocks
blocks shall
shall be
be supplied
supplied by the department
by the department free
free of of cost).
cost). sqm
sqm 402.95
16.85 Laying atator
or near ground level old
old kerb stones of of all types in position to the
the
required line, level and
and curvature, jointed with cement mortar 1:3 1:3 (1
(1 cement
:33 coarse
coarse sand),
sand), including
including making joints with
making joints with or
or without
without grooves
grooves (thickness
(thickness
of joints, except
of joints, at sharp
except at sharp curve,
curve, shall
shall not
not be
be more than 5 mm),
more than5 mm), including
including
making drainage opening wherever required etc. complete as per direction
of
of Engineer-in-charge.
Engineer-in-charge. (Length of finished
(Length of finished kerb
kerb edging shall be
edging shall be measured
measured
for payment). (Old
forpayment). (Old kerb stones shall
kerb stones shall be
be supplied
supplied by the department
by the department free
free
of
of cost)
cost) metre 109.45
16.86 Providing and
and laying gang saw saw cut
cut 18 mmmm thick, mirror polished pre
moulded and pre pre polished machine cutcutgranite
granite stone of
of required size and
and
shape of approved shade,
shape ofapproved shade, colour and texture
colour and texture in footpath, flooring
in footpath, flooring cut granite
cut granite
stone of and shape of
of required size and of approved shade, colour and and texture
in footpath, flooring
in footpath, flooring in
in road
road side
side plazas and similar
plazas and similar locations,
locations, laid over 20
laid over 20
mm thick base
mm thick base of cement mortar
ofcement mortar11:4:4 (1cement
(1 cement::4 4 coarse
coarse sand)
sand) including
including
grouting the joints with white cement mixed with matching pigment, epoxy
touch ups
ups etc. complete as perper direction of Engineer-in-Charge.
16.86.1
16.86.1 With granite stone of
of area less than 0.50 sqm. sqm
sqm 4746.20
16.87 Providing and
and laying gang saw cut 30 mm
saw cut mm thick, mirror polished pre
moulded and prepre polished machine cut cutgranite
granite stone of
of required size and
and
shape
shape of approved shade,
ofapproved shade, colour
colour and
and texture
texture in footpath, flooring
in footpath, flooring in
in road
road
side plazas and locations, laid over 20
and similar locations, mm thick base of
20 mm of cement
mortar
mortar11:4
:4 (1 cement : 4 coarse
(1 cement:4 coarse sand)
sand) including grouting the
including grouting the joints
joints with
with
white cement mixed with matching pigment, epoxy touch ups ups etc. complete
per direction of Engineer-in-Charge.
as per
16.87.1
16.87.1 With granite stone ofcolour
of colour black, cherry/ruby red of area less
than 0.50 sqm. sqm
sqm 4950.90
16.87.2 With granite stone ofof all colour except black, cherry/ruby red
of area less than 0.50 sqm. sqm
sqm 5272.05
16.88 Providing
Providing and
and laying
laying matt finished vitrified
matt finished vitrified tile
tile of
of size
size 100x100x16
100x100x16 mmmm
having water absorption
having water absorption less than 0.5%
less than 0.5% and and conforming
conforming toto IS:
IS: 15622
15622
of approved make
of approved make inin all
all colours
colours and shades in
and shades out door
in out door floors
floors such
such as
as
footpath, court yard multi models etc., laid on on 20 mm thick base ofcement
20 mm of cement
mortar
mortar 1:4
1:4 (1cement
(1 cement:4 : 4 coarse
coarse sand)
sand) inin all shapes & patterns
all shapes& patterns including
including
grouting the joints with white cement mixed with matching pigments etc.
complete as direction of Engineer-in-Charge. sqm
sqm 2159.85
16.89 Providing
Providing and
and laying
laying matt finished vitrified
matt finished vitrified tile
tile of
of size
size 300x300x9.8
300x300x9.8 mm mm
having with water
having with water absorption
absorption less than 0.5%
less than and conforming
0.5% and conforming to to IS:
IS: 15622
15622
of approved make
ofapproved make in
in all colours and
all colours and shades
shades in for outdoor
in for outdoor floors
floors such
such as
as
footpath, court yard, multi modals location etc., laid on on 20 mm thick base
20 mm
of cement mortar
ofcement mortar 1:4
1:4 (1 cement : 4 coarse
(1 cement:4 coarse sand)
sand) in in all
all shapes
shapes&& patterns
patterns
including grouting the joints with white cement mixed with matching
pigments etc. complete as perper direction of Engineer-in-Charge. sqm
sqm 1455.65

260
260 SUB HEAD:: 16.0
SUB Y6.0 ROAD
ROAO WORK
WORf
Code No Description Unit Rate
16.90 and laying tactile tile (for vision impaired persons as per
Providing and
standards)
standards) ofof size
size 300x300x9.8
300x300x9.8 mm mm having with water
having with water absorption
absorption less
less
than 0.5%
than 0.5% and
and conforming
conforming to to IS:15622
IS:15622 ofof approved
approved make
make in all colours
in all colours
and
and shades
shades in for outdoor
in for outdoor floors
floors such as footpath,
such as footpath, court
court yard,
yard, multi
multi modals
modals
location etc., laid on
on 2020 mm
mm thick base of mortar11:4
of cement mortar :4 (1
(1 cement:
cement :
4 4 coarse
coarse sand)
sand) in all shapes&
in all shapes & patterns
patterns including grouting the
including grouting the joints
joints with
with
white cement mixed with matching pigments etc. complete as per direction
of Engineer-in-Charge. sqm
sqm 2017.60
16.91
16.91 Providing and
and laying factory made chamfered edge Cement Concrete
paver
paver blocks
blocks in footpath, parks,
in footpath, parks, lawns,
lawns, drive ways or
drive ways or light traffic parking
light traffic parking
etc, of required strength, thickness&
thickness & size/ shape, made by bytable
table vibratory
method
method using
using PU
PU mould,
mould, laid
laid in
in required colour & pattern
required colour& over 50
pattern over 50 mm
mm
thick compacted bed of of sand, compacting and and proper embedding/laying
of inter locking paver blocks into the
of the sand bedding layer through vibratory
compaction
compaction by by using
using plate vibrator, filling
plate vibrator, filling the
the joints
joints with
with sand
sand and
and cutting
cutting
of
of paver
paver blocks as per
blocks as per required
required size
size and
and pattern, finishing and
pattern, finishing sweeping
and sweeping
extra sand. complete all as as per
per direction of Engineer-in-Charge.
16.91.1
16.91.1 60 mm
60 mm thick cement concrete paver block of M-35 grade with
approved colour, design&
design & pattern. sqm
sqm 1045.65
16.91.2 80 mm
80 mm thick C.C. paver block of M-35 grade with approved
colour design and
and pattern. sqm
sqm 1091.50
16.92 Providing and fixing
Providing and fixing 10x10x7.50
10x10x7.50 cm cm Granite
Granite stone
stone block
block hand
hand cut
cut and
and
chisel dressed on
chisel dressed top, for
on top, for paving
paving in floors, drains
in floors, etc. laid
drains etc. over 20
laid over 20 mm thick
mm thick
base
base mortar
mortar 1:4
1:4 (1 cement :4 4 coarse
(1 cement: coarse sand) with joints
sand) with joints 10
10 mm wide filled
mm wide filled
with same mortar including ruled pointing etc. complete as per direction of
engineer-in-charge. sqm
sqm 2189.15
16.93 Providing and 100 mm
and placing in position 100 mm thick factory made machine
batched&& machine mixed Precast RCC
batched RCC Rectangular Covers on drains of
footpath of various sizes, of M-25 grade cement concrete for RCC work,
for RCC
including cost of centering,
centering, shuttering,
shuttering, reinforcement of of88 mm
mm dia TMTTMT
bars of Fe 500
of Fe 500 grade@
grade @ maximum 100 100mmmm c/c
c/c on
on both ways, neat cement
punning
punning onon finished
finished surface,
surface, properly
properly encased
encased onon all edges with
all edges with 1.6
1.6 mm
mm
thick, 100
100 mm
mm wide MS MS sheet duly painted over priming coat, reinforcement
to be
be welded atedges
at edges with MS
MS sheet and
and providing
providing22 Nos. 12 mm mm dia
dia bar
forhooks etcincluding
for hooks etc including cost of cartage,
cartage, all leads
leads&& lift,
lift, handling at site etc.
all complete as per direction of Engineer-in-Charge. sqm
sqm 3081.95
16.94 Providing && making Gabion structure with Mechanically Woven Double
Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per per IS
IS
16014:2012,MORTH Clause 2500, of of required size, Mesh Type 10x12
(D=100
(D=100 mm with tolerance
mm with tolerance of+
of ± 2%) Zinc coated,
2%) Zinc coated, Mesh wire diameter
Mesh wire diameter
mm, mechanically edged/selvedged with partitions at every 1m
3.0 mm, 1m interval
and shall have minimum 10 numbers of
and of openings perper meter of of mesh
perpendicular to twist, tying with lacing wire of diameter 2.2 mm,
mm, supplied
supplied@@
3%
3% by weight of
by weight of Gabion
Gabion boxes, filled with
boxes, filled with boulders with least
boulders with dimension of
least dimension of
200 mm,
200 mm, as per drawing, all complete as per direction
direction of Engineer-in-charge. cum
cum 4178.00
16.95 Providing&& making Gabion structure with Mechanically Woven Double
Providing
Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per per IS
IS
16014:2012,MORTH Clause 2500, of of required size, Mesh Type 10x12
(D=100
(D=100 mm with tolerance
mm with tolerance ofof +± 2%)
2%) Zinic+PVC
Zinic+PVC coated,
coated, Mesh
Mesh wirewire
diameter 2.7/3.7 mm,
mm, mechanically edged/selvedged with partitions at
1m interval and
every 1m and shall have minimum 10 numbers ofopenings of openings per per
meter of
of mesh perpendicular to twist, tying with lacing wire of diameter
2.2/3.2mm(ID/OD), supplied @3%
2.2/3.2mm(ID/OD), supplied @3% by weight of
by weight of Gabion
Gabion boxes, filled with
boxes, filled with
boulders with least dimension of200 mm, as per drawing, all complete as
of 200 mm,
per directions of Engineer-in-charge. cum
cum 4569.25

sua HeAD
SUB HEAD:: 16.0
16.0 RoAD woRK
ROAD WORK 261
Code No Description Unit Rate
16.96 Providing&& making Gabion structure with Mechanically Woven Double
Providing
Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per per ISIS
16014:2012,MORTH Clause 2500, of of required size, Mesh Type 10x12
(D=100
(D=100 mm with tolerance
mm with tolerance ofof +2%),
±2%), Zinic+10%
Zinic+10% AI
Al alloy+PVC
alloy+PVC coated,
coated,
Mesh wire diameter
Mesh wire 2.7/3.7 mm
diameter 2.7/3.7 mm (ID/OD),
(ID/OD), mechanically edged/selvedged
mechanically edged/selvedged
with partitions at every 1m
1m interval and
and shall have minimum 10 numbers of of
openings per meter ofmesh
of mesh perpendicular to twist, tying with lacing wire of
diameter 2.2/3.2 mm(ID/OD),
diameter 2.2/3.2 mm(ID/OD), supplied
supplied @3%
@3% by weight of
by weight of Gabion
Gabion boxes,
boxes,
filled with
filled with boulders with least
boulders with dimension of
least dimension of 200
200 mm,
mm, asas per
per drawing,
drawing, all
all
complete as per directions of Engineer-in-charge. cum
cum 4882.20

262
262 sua HEAD
SUB HeAD:: 16.0
Ys.o ROAD
RodO WORK
woRf
SUB HEAD
SUB HEAD:: 17.0
SANITARY INSTALLATIONS
17.0 SANITARY INSTALLATIONS

Code No Description Unit Rate


17.1
17.1 Providing
Providing and fixing water
and fixing water closet
closet squatting
squatting pan pan (Indian type W.C.
(Indian type W.C. pan
pan)) with
with
100
100 mm
mm sand
sand cast
cast Iron
IronPP orS
or S trap,
trap, 1010 litre
litre low
low level white P.V.C.
level white flushing
P.V.C. flushing
cistern,
cistern, including flush pipe,
including flush with manually
pipe, with controlled device
manually controlled device (handle
(handle lever)
lever)
conforming
conforming to to IS
IS:: 7231, with all
7231, with all fittings
fittings and
and fixtures
fixtures complete,
complete, including
including
cutting and making
cutting and making good the walls and
good thewalls floors wherever
and floors wherever required:
required:
17.1.1
17.1.1 White Vitreous
White Vitreous china
china Orissa
Orissa pattern
pattern W.C.W.C. pan of size 580x440
pan ofsize 580x440
mm with integral type foot rests
mm each 6767.40
17.1.2 Stainless
Stainless Steel AISI-304(18/8) Orissa
SteeIAISI-304(18/8) Orissa pattern
pattern W.C.W.C. pan
pan of size
ofsize
585x480
585x480 mm with flush
mm with flush pipe
pipe and
and integrated
integrated type type foot
foot rests
rests each 11390.95
17.2 Providing
Providing and fixing white
and fixing white vitreous
vitreous chinachina pedestal
pedestal type type water
water closet
closet
(European
(European type type W.C.
W.C. pan) with seat
pan) with seat and
and lid,
lid, 10
10 litre
litre low
low level white P.V.C.
level white P.V.C.
flushing cistern,
flushing cistern, including flush pipe,
including flush with manually
pipe, with controlled device
manually controlled device
(handle
(handle lever),
lever), conforming
conforming to to ISIS :: 7231,
7231, with with all fittings and
all fittings and fixtures
fixtures
complete,
complete, including cutting and
including cutting and making
making goodgood thewalls
the walls and floors wherever
and floors wherever
required::
required
17.2.1
17.2.1 W.C. pan with ISI marked white solid plastic seat and and lid each 6515.55
17.2.2 W.C. pan with ISI marked black solid plastic seat and and lid each 6383.25
17.3 Providing
Providing and fixing white
and fixing white vitreous
vitreous chinachina pedestal
pedestal type type water
water closet
closet
(European
(European type)type) with
with seat
seat and
and lid,lid, 10
10 litre
litre low
low level white vitreous
level white vitreous china
china
flushing cistern
flushing cistern&& C.P. flush bend
C.P. flush bend withwith fittings&
fittings & C.I.C.I. brackets,
brackets, 40 40 mm flush
mm flush
bend, overflow arrangement
bend, overflow arrangement with with specials
specials of of standard
standard make make and and mosquito
mosquito
proof coupling of approved municipal design complete, including painting
of fittings and
of fittings and brackets, cutting and
brackets, cutting and making
making good good the the walls
walls and
and floors
floors
wherever required
required::
17.3.1
17.3.1 W.C. pan with ISI marked white solid plastic seat and and lid each 8006.60
17.3.2 W.C. pan with ISI marked black solid plastic seat and and lid each 7874.30
17.4 Providing and fixing
Providing and fixing white
white vitreous
vitreous china
china flat flat back
back or wall corner
or wall corner typetype
lipped front urinal basin of 430x260x350 mm mm and 340x410x265 mm mm sizes
respectively with automatic
respectively with automatic flushing
flushing cistern
cistern withwith standard
standard flushflush pipe
pipe andand
C.P. brass spreaders with brass unions and and G.IG.I clamps complete, including
painting
painting of fittings and
of fittings and brackets, cutting and
brackets, cutting and making
making goodgood the the walls
walls andand
floors wherever
floors wherever required
required::
17.4.1
17.4.1 One
One urinal
urinal basin with 5 litre
basin with5 white P.V.C.
litre white P.V.C. automatic flushing
automatic flushing
cistern each 6258.75
17.4.2 Range
Range of two urinal
oftwo urinal basins with 5 litre
basins with5 white P.V.C.
litre white P.V.C. automatic
automatic
flushing cistern
flushing cistern each 9612.40
17.4.3 Range
Range of three urinal
ofthree urinal basins with 10litre
basins with white P.V.C.
10Iitre white P.V.C. automatic
automatic
flushing cistern
flushing cistern each 13417.30
17.4.4 Range of four urinal
Range offour urinal basins with 10
basins with 10 litre white P.V.C.
litre white P.V.C. automatic
automatic
flushing cistern
flushing cistern each 18579.95
17.5 Providing and fixing
Providing and fixing white
white vitreous
vitreous china flat back
china flat back half stall urinal
half stall urinal of
of size
size
580x380x350
580x380x350 mm with white
mm with white PVC automatic flushing
PVC automatic flushing cistern, with fittings,
cistern, with fittings,
standard
standard size
size C.P.
C.P. brass flush pipe,
brass flush spreaders with
pipe, spreaders with unions
unions andand clamps
clamps (all (all
in
in C.P.
C.P. brass) with waste
brass) with waste fitting
fitting asas per
per IS
IS: : 2556,
2556, C.I. trap with
C.I. trap with outlet grating
outlet grating
and
and other
other couplings
couplings in in C.P.
C.P. brass,
brass, including
including painting
painting of fittings and
of fittings and cutting
cutting
and
and making good thewalls
making good the walls andand floors
floors wherever
wherever required
required::
17.5.1
17.5.1 Single
Single half stall urinal
half stall with 5 litre
urinal with5 litre P.V.C.
P.V.C. automatic flushing
automatic flushing
cistern each 12071.75

SUB HEAD:: 17.0 SANITARY


SUB SANITARY INSTALLATIONS 265
Code No Description Unit Rate
17.5.2 Range of two half
Range oftwo half stall
stall urinals with 5 litre
urinals with5 litre P.V.C. automatic
P.V.C. automatic
flushing cistern
flushing cistern each 18008.75
17.5.3 Range of three half
Range ofthree stall urinals
half stall with 10
urinals with 10 litre
litre P.V.C. automatic
P.V.C. automatic
flushing cistern
flushing cistern each 22058.25
17.5.4 Range of four half
Range offour stall urinals
half stall with 10
urinals with 10 litre
litre P.V.C. automatic
P.V.C. automatic
flushing cistern
flushing cistern each 25969.45
17.6 Providing and fixing
Providing and fixing one
one piece
piece construction
construction whitewhite vitreous china squatting
vitreous china squatting
plate with an
plate with an integral
integral longitudinal flushing pipe,
longitudinal flushing white P.V.C.
pipe, white automatic
P.V.C. automatic
flushing cistern,
flushing with fittings,
cistern, with fittings, standard
standard sizesize G.I.
G.I./ / PVC flush pipe
PVC flush for back
pipe for back
and front flush
and front flush with
with standard
standard spreader
spreader pipes with fittings,
pipes with fittings, G.I
G.I clamps and
clamps and
C.P.
C.P. brass coupling complete,
brass coupling complete, including
including painting
painting of of fittings
fittings and
and cutting
cutting and
and
making good thewalls
making good the walls and
and floors
floors etc.
etc. wherever
wherever required
required::
17.6.1
17.6.1 Single
Single squatting
squatting plate with 5 litre
plate with5 litre P.V.C. automatic flushing
P.V.C. automatic flushing cistern
cistern each 9256.45
17.6.2 Range
Range of of two
two squatting
squatting plates with 5 litre
plates with5 litre P.V.C.
P.V.C. automatic
automatic
flushing cistern
flushing cistern each 13476.35
17.6.3 Range
Range of three squatting
ofthree squatting plates with 10
plates with 10 litre
litre P.V.C. automatic
P.V.C. automatic
flushing cistern
flushing cistern each 17702.20
17.6.4 Range of four squatting
Range offour squatting plates with 10
plates with 10 litre
litre P.V.C. automatic
P.V.C. automatic
flushing cistern
flushing cistern each 21203.20
17.7 Providing
Providing andand fixing
fixing wash
wash basin with C.I.
basin with C.I. brackets,
brackets, 15
15 mm
mm C.P.
C.P. brass
brass pillar
pillar
taps, 32
32 mmmm C.P. brass waste of of standard pattern, including painting of
fittings and
fittings and brackets,
brackets, cutting and making
cutting and good thewalls
making good the walls wherever
wherever require:
require:
17.7.1
17.7.1 White Vitreous
White Vitreous China Wash basin
China Wash size 630x450
basin size 630x450 mm with a
mm witha
pair of 15
15 mm
mm C.P. brass pillar taps each 2648.85
17.7.2 White Vitreous
White Vitreous China Wash basin
China Wash basin size 630x450 mm
size 630x450 with a
mm witha
single 15
15 mm
mm C.P. brass pillar tap
tap each 2226.35
17.7.3 White Vitreous
White Vitreous China Wash basin
China Wash size 550x400
basin size 550x400 mm with a
mm witha
pair of 15
15 mm
mm C.P. brass pillar taps each 2301.75
17.7.4 White Vitreous
White Vitreous China
China Flat
Flat back wash basin
back wash size 550x
basin size 400 mm
550x 400 mm
with single 1515 mm
mm C.P. brass pillar tap
tap each 1879.20
17.7.5 White Vitreous
White Vitreous China Angle back
China Angle wash basin
back wash size 600
basin size 600xx 480
480
mm with single 15
mm 15 mm
mm C.P. brass pillar tap
tap each 2226.35
17.7.6 White Vitreous
White Vitreous China Angle back
China Angle wash basin
back wash size 400
basin size 400xx 400
400
mm with single 15
mm 15 mm
mm C.P. brass pillar tap
tap each 1756.85
17.7.7 White Vitreous
White Vitreous China
China Flat
Flat back wash basin
back wash size 450x
basin size 450x 300
300 mm
mm
with single 1515 mm
mm C.P. brass pillar taptap each 1513.60
17.7.8 White Vitreous
White Vitreous China
China Surgeon
Surgeon typetype wash
wash basin
basin ofof size
size
660x460 mm mm witha
with a pair of 15
15 mm
mm C.P. brass pillar taps with
elbow including operated levers each 3600.60
17.7.9 White Vitreous
White Vitreous China
China Surgeon
Surgeon typetype wash
wash basin
basin ofof size
size
660x460 mm mm with single 15 15 mm
mm C.P. brass pillar taps with
elbow operated levers ISI Marked each 2940.50
17.7.10 Stainless Steel AISI-304(18/8) Round
Stainless SteeIAISI-304(18/8) Round basin 405x355 mm
basin 405x355 with
mm with
single 15
15 mm
mm C.P. brass pillar tap
tap each 3438.40
17.7.11
17.7.11 Stainless
Stainless Steel AISI-304(18/8) Wash
Steel AISI-304(18/8) Wash basin
basin 530x345
530x345 mm with
mm with
single 15
15 mm
mm C.P. brass pillar tap
tap each 4149.75
17.7A Providing
Providing and fixing wash
and fixing wash basin with C.I.
basin with C.I. brackets,
brackets, 1515 mm dia CP
mm dia CP Brass
Brass
single hole basin mixer of of approved quality andand make, including painting
of fittings and
of fittings and brackets,
brackets, cutting and making
cutting and making goodgood the
the walls
walls wherever
wherever
required:-

266
266 SUB HEAD:: 17.0 SANITARY
SUB SANITARY INSTALLATIONS
Code No Description Unit Rate
(a) White Vitreous
(a) White Vitreous China Wash basin
China Wash size 550x400
basin size 550x400 mm with a 15
mm witha 15 mm
mm CP
CP
Brass single hole basin mixer each 3960.55
17.7B Providing
Providing and fixing wash
and fixing wash basin with C.I.
basin with C.I. brackets,
brackets, 15
15 mm
mm PTMT
PTMT pillar
pillar
cock, 3232 mm
mm PTMT waste coupling of standard pattern,
pattern, including painting
of fittings and
of fittings and brackets,
brackets, cutting and making
cutting and good the
making good the walls
walls wherever
wherever
required. White Vitreous
required. White Vitreous China
China Flat
Flat back wash basin
back wash size 550x400
basin size 550x400 mm
mm
with single 15
15 mm
mm PTMT pillar cock. each 1550.60
17.8 Providing and fixing
Providing and fixing white
white vitreous
vitreous china
china pedestal for wash basin
pedestal forwash basin completely
completely
recessed at the back
recessed atthe for the reception
back forthe reception of
of pipes and fittings.
pipes and fittings. each 1683.35
17.9 Providing
Providing and fixing kitchen
and fixing kitchen sink with C.I.
sink with C.I. brackets,
brackets, C.P.
C.P. brass chain with
brass chain with
rubber plug, 40 mm C.P. brass waste complete, including painting the
40 mm the
fittings and
fittings and brackets,
brackets, cutting and making
cutting and good thewalls
making good the walls wherever
wherever required:
required:
17.9.1
17.9.1 White glazed
White glazed fire
fire clay
clay kitchen
kitchen sink of size
sink of size 600x450x 250 mm
600x450x 250 mm each 3892.75
17.10 Providing
Providing and fixing Stainless
and fixing Stainless Steel
SteelA A ISI
ISI 304
304 (18/8)
(18/8) kitchen
kitchen sink as per
sink as per
IS:13983 with C.I. brackets andand stainless steel plug 40 mm, including
40 mm,
painting
painting of fittings and
of fittings and brackets,
brackets, cutting
cutting and
and making good the
making good the walls
walls
wherever required
required::
17.10.1
17.10.1 Kitchen sink with drain board
17.10.1.1
17.10.1.1 510x1040 mm
mm bowl depth 250 mm
250 mm each 6945.60
17.10.1.2 mm bowl depth 225
510x1040 mm mm
225 mm each 7514.65
17.10.1.3 mm bowl depth 200
510x1040 mm mm
200 mm each 7159.00
17.10.1.4 510x1040 mm
mm bowl depth 178
178 mm
mm each 6917.20
17.10.2 Kitchen sink without drain board
17.10.2.1
17.10.2.1 610x510 mm
mm bowl depth 200 mm
200 mm each 4940.80
17.10.2.2 610x460 mm
mm bowl depth 200 mm
200 mm each 3873.80
17.10.2.3 470x420 mm
mm bowl depth 178
178 mm
mm each 3407.20
17.11
17.11 Providing
Providing andand fixing
fixing white
white vitreous
vitreous china
china laboratory sink with
laboratory sink with C.I.
C.I. brackets,
brackets,
C.P. brass chain with rubber plug, 40 mm C.P
40 mm C.P brass waste and 40 mm mm C.P.
brass trap with necessary C.P. brass unions complete, including painting of
fittings and
fittings and brackets, cutting and
brackets, cutting and making good thewall
making good the wall wherever
wherever required
required::
17.11.1
17.11.1 Size 450x300x150 mm
mm each 5020.85
17.11.2 mm
Size 600x450x200 mm each 6585.80
17.12 Providing and fixing
Providing and fixing draining
draining board with C.I.
board with C.I. brackets
brackets including
including painting of
painting of
brackets, cutting and
and making good thewalls
the walls wherever required
required::
17.12.1
17.12.1 White glazed
White glazed fire
fire clay
clay draining
draining board
board of size 600x450x
ofsize 600x450x 25
25 mm
mm each 1579.65
17.13 Providing and fixing
Providing and fixing white
white vitreous
vitreous china
china water
water closet squatting pan
closet squatting pan (Indian
(Indian
type) :
type):
17.13.1
17.13.1 Long pattern W.C. pan ofsize
of size 580 mm
580 mm each 1959.80
17.13.2 Orissa pattern W.C. pan ofsize mm
of size 580x440 mm each 3169.05
17.14 Extra for
for using coloured W.C. pan instead of white W.C. pan
pan::
17.14.1
17.14.1 Orissa pattern W.C. pan 580x440 mm
mm each 426.80
17.15 Providing and fixing
Providing and fixing white
white vitreous
vitreous china
china pedestal type (European
pedestal type type/
(European type/
wash down
wash down type)
type) water
water closet
closet pan.
pan. each 2784.95
17.16 Extra for using
Extra for coloured pedestal
using coloured type W.C
pedestal type W.C pan
pan (European type) with
(European type) with low
low
level cistern of same colour instead of white vitreous china W.C pan and
W.C pan and
cistern. each 170.70

SUB HEAD:: 17.0 SANITARY


SUB SANITARY INSTALLATIONS 267
267
Code No Description Unit Rate
17.16A Providing and fixing8
Providing and fixing 8 mm
mm dia
dia C.P.
C.P./ / S.S.
S.S. Jet
Jet with
with flexible
flexible tube
tube upto
upto11 metre
metre
long with S.S. triangular plate to Eureopean type W.C. of ofquality
quality and
and make
asapproved
as approved by Engineer - in - charge. each 349.15
17.17 Providing
Providing and fixing a pair
and fixinga pair of white vitreous
of white vitreous china foot rests
china foot of standard
rests of standard
pattern for squatting pan
pan water closet
closet::
17.17.1
17.17.1 250x130x30 mm
mm pair 244.85
17.17.2 250x125x25 mm
mm pair 256.25
17.18 Providing and fixing
Providing and fixing P.V.C.
P.V.C. low
low level flushing cistern
level flushing cistern with
with manually
manually
controlled device (handle
controlled device (handle lever)
lever) conforming to IS
conforming to IS:: 7231,
7231, with
with all fittings
all fittings
and fixtures complete.
and fixtures complete.
17.18.1
17.18.1 10 litre capacity - White
10 each 1190.65
17.18.2 10 litre capacity - coloured
10 each 1136.60
17.19 Providing and fixing
Providing and fixing controlled flush, low
controlled flush, low level
level cistern
cistern made of vitreous
made ofvitreous
china with all
china with fittings complete.
all fittings complete.
17.19.1
17.19.1 10
10 litre
litre (full flush) capacity-white
(full flush) capacity-white each 2243.75
17.19.2 10
10 litre
litre (full flush) capacity-coloured
(full flush) capacity-coloured each 2912.40
17.20 Providing
Providing and fixing solid
and fixing solid plastic seat with
plastic seat with lid for pedestal
lid for type W.C.
pedestal type W.C. pan
pan
complete:
complete :
17.20.1
17.20.1 White solid plastic seat with lid each 684.85
17.20.2 Black solid plastic seat with lid each 552.55
17.20.3 Coloured
Coloured (other than black
(other than black&& white)
white) solid
solid plastic
plastic seat with lid
seat with lid each 590.95
17.22 Providing and fixing
Providing and fixing G.I.
G.I. inlet connection for
inlet connection for flush
flush pipe
pipe connecting with
connecting with
W.C. pan. each 142.85
17.22A Providing and fixing
Providing and fixing CP
CP Brass
Brass 32 32 mm size Bottle
mm size Trap ofapproved
Bottle Trap of approved quality
quality
&& make and
and as perthedirection
as per the direction of Engineer-in-charge. each 1034.80
17.22B Providing and fixing
Providing and fixing CP
CP Brass
Brass Single
Single lever telephonic wall
lever telephonic wall mixer
mixer of
of quality
quality
&& make as as approved by Engineer in charge.
(a)
(a) 15
15 mm
mm nominal
nominal diadia each 6940.75
17.23 Providing and fixing
Providing and fixing white
white vitreous
vitreous china
china flat
flat back
back oror wall
wall corner
corner type
type
lipped front urinal basin of 430x260x350 mm mm or or 340x410x265 mm mm sizes
respectively.
respectively. each 1648.95
17.24 Providing
Providing and fixing white
and fixing white vitreous
vitreous china
china squatting
squatting plate
plate urinal with integral
urinal with integral
rim
rim longitudinal flush pipe.
longitudinal flush pipe. each 4048.65
17.25 Providing and fixing
Providing and fixing white
white vitreous
vitreous china wash basin
china wash basin including
including making
making allall
connections but
connections excluding the
but excluding the cost of fittings:
cost of fittings :
17.25.1
17.25.1 Flat back wash basin of size 630x450 mm mm each 1339.70
17.25.2 Flat back wash basin of size 550x400 mm mm each 992.60
17.25.3 Angle back wash basin of size 600x480 mm mm each 1339.70
17.25.4 Angle back wash basin of size 400x400 mm mm each 870.25
17.25.5 Flat back wash basin of size 450x300 mm
mm each 627.00
17.25.6 Surgeon type wash basin of size 660x460 mm
mm each 1816.30
17.26 Providing
Providing and fixing kitchen
and fixing kitchen sink
sink including
including making all connections
making all excluding
connections excluding
cost of
cost fittings.
of fittings.
17.26.1
17.26.1 White glazed
White fire clay
glazed fire clay sink of size
sink of size 600x450x250
600x450x250 mm mm each 2199.80
17.27 Providing and fixing
Providing and fixing white
white vitreous
vitreous china
china laboratory sink including
laboratory sink including making
making
all connections
all connections excluding cost of
excluding cost fittings :
of fittings:
17.27.1
17.27.1 Size 450x300x150 mm mm each 2512.75

268 SUB HEAD:: 17.0 SANITARY


SUB SANITARY INSTALLATIONS
Code No Description Unit Rate
17.27.2 Size 600x450x200 mm
mm each 4077.65
17.28 Providing
Providing and fixing P.V.C.
and fixing waste pipe
P.V.C. waste for sink
pipe for sink or wash basin
or wash basin including
including
P.V.C. waste fittings
P.V.C. waste fittings complete.
complete.
17.28.1
17.28.1 Semi rigid pipe
17.28.1.1
17.28.1.1 32 mm
32 mm dia each 103.90
17.28.1.2 40 mm dia
40 mm each 116.70
17.28.2 Flexible pipe
17.28.2.1
17.28.2.1 32 mm dia
32 mm each 119.55
17.28.2.2 40 mm dia
40 mm each 119.55
17.29 Providing and fixing
Providing and fixing 100
100 mm
mm sand cast Iron
sand cast grating for
Iron grating for gully
gully trap.
trap. each 53.25
17.30 Providing and fixing
Providing and fixing in
in position 25 mm
position 25 mm diameter
diameter mosquito
mosquito proof
proof coupling of
coupling of
approved municipal design. each 55.65
17.31
17.31 Providing and fixing
Providing and fixing 600x450
600x450 mm
mm beveled edge mirror
beveled edge of superior
mirror of superior glass
glass
(of approved quality)
(ofapproved complete with6
quality) complete with 6 mm thick hard
mm thick hard board ground fixed
board ground fixed to
to
wooden cleats with C.P. brass screws and
and washers complete. each 1607.95
17.32 Providing and fixing
Providing and fixing mirror of superior
mirror of glass (of
superior glass approved quality)
(ofapproved quality) and
and of
of
required shape and size with plastic moulded frame ofapproved
of approved make and and
shade with6 mm thick hard board backing
with 6 mm backing::
17.32.1
17.32.1 Circular shape 450 mm
mm dia
dia each 1479.05
17.32.2 Rectangular shape 453x357 mm
mm each 1361.80
17.32.3 Oval shape 450x350
Oval shape 450x350 mm
mm (outer dimensions)
(outer dimensions) each 1377.10
17.32.4 Rectangular shape 1500x450 mm
mm each 2093.00
17.33 Providing
Providing and fixing 600x120x5
and fixing 600x120x5 mm glass shelf
mm glass shelf with
with edges
edges round off,
round off,
supported on
on anodised aluminium angle frame with C.P. brass brackets
and guard
and guard rail complete fixed
rail complete fixed with
with 40
40 mm
mm long screws, rawl
long screws, rawl plugs
plugs etc.,
etc.,
complete. each 1083.50
17.34 Providing and fixing
Providing and fixing toilet
toilet paper
paper holder
holder::
17.34.1
17.34.1 C.P. brass each 803.70
17.34.2 Vitreous china
Vitreous china each 546.35
17.35 Providing and fixing
Providing and fixing soil, waste and
soil, waste and vent
vent pipes
pipes::
17.35.1
17.35.1 100 mm
100 mm dia
17.35.1.1
17.35.1.1 Sand cast iron S&S
S&S pipe as
as per IS: 1729 metre 1151.90
17.35.1.2 Centrifugally cast (spun)
Centrifugally cast (spun) iron socket & spigot
iron socket& spigot
(S&S)
(S&S) pipe
pipe as
as per
per IS:
IS: 3989
3989 metre 1180.75
17.35.1.3 Hubless
Hubless centrifugally
centrifugally cast
cast (spun)
(spun) iron
iron pipes
pipes
epoxy coated inside
inside&& outside IS:15905 metre 1169.30
17.35.2 75
75 mmmm diameter
diameter::
17.35.2.1
17.35.2.1 Sand cast iron S&S
S&S pipe asas per IS: 1729 metre 1044.75
17.35.2.2 Centrifugally
Centrifugally cast
cast (spun)
(spun) iron
iron socketed
socketed pipe as
pipe as
per IS: 3989 metre 1186.00
17.35.2.3 Hubless
Hubless centrifugally
centrifugally cast
cast (spun)
(spun) iron
iron pipes
pipes
inside&& outside IS:15905
epoxy coated inside metre 964.25
17.36 Providing
Providing and filling the
and filling the joints
joints with
with spun
spun yarn,
yarn, cement slurry and
cement slurry and cement
cement
mortar
mortar 1:2
1:2((11 cement:
cement :2 2 fine
fine sand)
sand) in
in S.C.I./
S.C.I./ C.I.
C.I. Pipes
Pipes::
17.36.1
17.36.1 75 mm
75 mm dia pipe each 168.20
17.36.2 100 mm
100 mm dia pipe each 198.15

SUB HEAD:: 17.0 SANITARY


SUB SANITARY INSTALLATIONS 269
269
Code No Description Unit Rate
17.37 Providing
Providing and fixing M.S.
and fixing M.S. holder-bat
holder-bat clamps
clamps ofof approved
approved design
design to
to Sand
Sand
Cast
Cast iron/cast
iron/cast iron
iron (spun)
(spun) pipe embedded in
pipe embedded and including
in and cement concrete
including cement concrete
blocks 10x10x10 cm cm of mix (1
of 1:2:4 mix (1 cement:2
cement : 2 coarse sand:
sand :4 4 graded
stone aggregate 20
stone aggregate 20 mm
mm nominal
nominal size),
size), including
including cost of cutting
cost of cutting holes and
holes and
making good thewalls
the walls etc.:
etc. :
17.37.1
17.37.1 For 100
For 100 mm
mm dia pipe each 362.85
17.37.2 75 mm
For 75 mm dia pipe each 360.00
17.38 Providing and fixing
Providing and fixing bend
bend of
of required degree with
required degree with access
access door,
door, insertion
insertion
rubber washer3 mm thick, bolts and
washer 3 mm and nuts complete.
17.38.1
17.38.1 100 mm
100 mm dia
17.38.1.1
17.38.1.1 S&S as
Sand cast iron S&S per IS
as per IS - 1729 each 598.50
17.38.1.2 S&S as
Sand cast iron S&S per IS
as per IS - 3989 each 705.20
17.38.1.3 Hubless
Hubless centrifugally
centrifugally cast
cast (spun)
(spun) iron
iron epoxy
epoxy
coated inside
inside&& outside as
as per IS:15905 each 567.20
17.38.2 75 mm
75 mm dia
17.38.2.1
17.38.2.1 S&S as
Sand cast iron S&S per IS - 1729
as per each 501.45
17.38.2.2 S&S as
Sand cast iron S&S per IS- 3989
as per each 522.80
17.38.2.3 Hubless
Hubless centrifugally
centrifugally cast
cast (spun)
(spun) iron
iron epoxy
epoxy
coated inside
inside&& outside asas per IS:15905 each 418.95
17.39 Providing
Providing and fixing plain
and fixing plain bend
bend of required degree.
ofrequired degree.
17.39.1
17.39.1 100 mm
100 mm dia
17.39.1.1
17.39.1.1 S&S as
Sand cast iron S&S per IS - 1729
as per each 470.45
17.39.1.2 S&S as
Sand cast iron S&S per IS
as per IS:: 3989 each 570.05
17.39.1.3 Hubless centrifugally cast
Hubless centrifugally cast (spun)
(spun) iron
iron pipes
pipes
epoxy coated inside
inside&& outside IS:15905 each 368.00
17.39.2 75 mm
75 mm dia
17.39.2.1
17.39.2.1 S&S as
Sand cast iron S&S as per
per IS -1729 each 376.25
17.39.2.2 S&S as
Sand cast iron S&S as per
per IS - 3989 each 390.50
17.39.2.3 Hubless centrifugally cast
Hubless centrifugally cast (spun)
(spun) iron
iron pipes
pipes
epoxy coated inside
inside&& outside IS:15905 each 252.50
17.40 Providing and fixing
Providing and fixing heel
heel rest sanitary bend
rest sanitary bend
17.40.1
17.40.1 100 mm
100 mm dia
17.40.1.1
17.40.1.1 S&S as
Sand cast iron S&S as per
per IS - 1729 each 584.25
17.40.1.2 S&S as
Sand cast iron S&S as per
per IS - 3989 each 548.70
17.40.2 75 mm
75 mm dia
17.40.2.1
17.40.2.1 Sand cast iron S&S
S&S as
as per
per IS - 1729 each 490.05
17.40.2.2 Sand cast iron S&S
S&S as
as per
per IS - 3989 each 504.30
17.41
17.41 Providing and fixing
Providing and fixing double
double equal junction of
equal junction of required degree with
required degree with access
access
door, insertion rubber washer3 mm thick, bolts and
washer 3 mm and nuts complete
complete::
17.41.1
17.41.1 100x100x100x100 mm mm
17.41.1.1
17.41.1.1 Sand cast iron S&S
S&S asas per
per IS
IS - 1729 each 1138.65
17.41.1.2 Sand cast iron S&S
S&S asas per
per IS
IS - 3989 each 1103.10
17.41.2 75x75x75x75 mm mm
17.41.2.1
17.41.2.1 Sand cast iron S&S
S&S as per IS
as per IS - 1729 each 842.90
17.41.2.2 Sand cast iron S&S
S&S as per IS
as per IS - 3989 each 885.60

270
270 SUB HEAD:: 17.0 SANITARY
SUB SANITARY INSTALLATIONS
Code No Description Unit Rate
17.42 Providing
Providing and fixing double
and fixing double equal
equal plain junction of
plain junction of required
required degree.
degree.
17.42.1
17.42.1 mm
100x100x100x100 mm
17.42.1.1
17.42.1.1 S&S as
Sand cast iron S&S per IS
as per IS - 1729 each 939.90
17.42.1.2 S&S as
Sand cast iron S&S per IS
as per IS - 3989 each 1075.05
17.42.1.3 Hubless centrifugally cast
Hubless centrifugally cast (spun)
(spun) iron
iron pipes
pipes
epoxy coated inside
inside&& outside IS:15905 each 760.70
17.42.2 mm
75x75x75x75 mm
17.42.2.1
17.42.2.1 S&S as
Sand cast iron S&S per IS
as per IS - 1729 each 625.20
17.42.2.2 S&S as
Sand cast iron S&S per IS
as per IS - 3989 each 803.05
17.42.2.3 Hubless centrifugally cast
Hubless centrifugally cast (spun)
(spun) iron
iron pipes
pipes
epoxy coated inside
inside&& outside IS:15905 each 418.95
17.43 Providing and fixing
Providing and fixing single
single equal
equal plain junction of
plain junction of required degree with
required degree with
access door, insertion rubber washer3 mm thick, bolts and
washer 3 mm and nuts complete.
17.43.1
17.43.1 100x100x100 mm mm
17.43.1.1
17.43.1.1 S&S as
Sand cast iron S&S per IS - 1729
as per each 726.55
17.43.1.2 S&S as
Sand cast iron S&S per IS - 3989
as per each 925.70
17.43.2 75x75x75 mmmm
17.43.2.1
17.43.2.1 S&S as
Sand cast iron S&S as per
per IS - 1729 each 629.50
17.43.2.2 S&S as
Sand cast iron S&S as per
per IS - 3989 each 665.05
17.44 Providing and fixing
Providing and fixing single
single equal
equal plain junction of
plain junction of required
required degree
degree::
17.44.1
17.44.1 mm
100x100x100 mm
17.44.1.1
17.44.1.1 S&S as
Sand cast iron S&S as per
per IS - 1729 each 626.95
17.44.1.2 S&S as
Sand cast iron S&S as per
per IS - 3989 each 811.90
17.44.1.3 Hubless centrifugally cast
Hubless centrifugally cast (spun)
(spun) iron epoxy
iron epoxy
inside&& outside as
coated inside as per IS:15905 each 581.45
17.44.2 mm
75x75x75 mm
17.44.2.1
17.44.2.1 Sand cast iron S&S
S&S as
as per
per IS - 1729 each 504.30
17.44.2.2 Sand cast iron S&S
S&S as
as per
per IS - 3989 each 561.20
17.44.2.3 Hubless centrifugally cast
Hubless centrifugally cast (spun)
(spun) iron epoxy
iron epoxy
inside&& outside as
coated inside as per IS:15905 each 337.85
17.45 Providing and fixing
Providing and fixing double
double unequal junction of
unequal junction of required degree with
required degree with
access door, insertion rubber washer33 mm
mm thick, bolts and
and nuts complete:
17.45.1
17.45.1 mm
100x100x75x75 mm
17.45.1.1
17.45.1.1 Sand cast iron S&S
S&S as
as per
per IS
IS - 1729 each 1153.30
17.45.1.2 Sand cast iron S&S
S&S as
as per
per IS
IS - 3989 each 1601.45
17.46 Providing and fixing
Providing and fixing double
double unequal
unequal plain junction of
plain junction of required
required degree
degree::
17.46.1
17.46.1 mm
100x100x75x75 mm
17.46.1.1
17.46.1.1 Sand cast iron S&S
S&S as per IS
as per IS - 1729 each 954.15
17.46.1.2 Sand cast iron S&S
S&S as per IS
as per IS - 3989 each 1402.30
17.46.1.3 Hubless
Hubless centrifugally
centrifugally cast
cast (spun)
(spun) iron epoxy
iron epoxy
inside&& outside as
coated inside as per IS:15905 each 607.05
17.47 Providing
Providing and fixing single
and fixing single unequal junction of
unequal junction of required degree with
required degree with access
access
door, insertion rubber washer3 mm thick, bolts and
washer 3 mm complete::
and nuts complete
17.47.1
17.47.1 100x100x75 mm mm
17.47.1.1
17.47.1.1 S&S as
Sand cast iron S&S per IS
as per IS - 1729 each 911.45

SUB HEAD:: 17.0 SANITARY


SUB SANITARY INSTALLATIONS 271
271
Code No Description Unit Rate
17.47.1.2 Sand cast iron S&S
S&S as per IS
as per IS - 3989 each 1146.20
17.48 Providing
Providing and fixing single
and fixing single unequal
unequal plain junction of
plain junction of required degree :
required degree:
17.48.1
17.48.1 100x100x75 mm mm
17.48.1.1
17.48.1.1 S&S as
Sand cast iron S&S per IS
as per IS - 1729 each 811.90
17.48.1.2 S&S as
Sand cast iron S&S per IS
as per IS - 3989 each 1032.40
17.48.1.3 Hubless
Hubless centrifugally
centrifugally cast
cast (spun)
(spun) iron
iron epoxy
epoxy
coated inside
inside&& outside as
as per IS:15905 each 551.55
17.49 Providing
Providing and fixing double
and fixing double equal
equal plain
plain invert
invert branch of required
branch of degree:
required degree:
17.49.1
17.49.1 100x100x100x100 mm mm
17.49.1.1
17.49.1.1 S&S as
Sand cast iron S&S per IS - 1729
as per each 883.00
17.49.1.2 S&S as
Sand cast iron S&S per IS 3989
as per each 989.70
17.49.1.3 Hubless centrifugally cast
Hubless centrifugally cast (spun)
(spun) iron
iron epoxy
epoxy
coated inside
inside&& outside as
as per IS:15905 each 1106.35
17.49.2 mm
75x75x75x75 mm
17.49.2.1
17.49.2.1 S&S as
Sand cast iron S&S as per
per IS - 1729 each 660.80
17.49.2.2 S&S as
Sand cast iron S&S as per
per IS - 3989 each 803.05
17.50 Providing and fixing
Providing and fixing single
single equal
equal plain
plain invert
invert branch of required
branch of degree :
required degree:
17.50.1
17.50.1 mm
100x100x100 mm
17.50.1.1
17.50.1.1 S&S as
Sand cast iron S&S as per
per iron 1729 each 698.05
17.50.1.2 S&S as
Sand cast iron S&S as per
per IS - 3989 each 747.85
17.50.1.3 Hubless centrifugally cast
Hubless centrifugally cast (spun)
(spun) iron epoxy
iron epoxy
inside&& outside as
coated inside as per IS:15905 each 645.45
17.50.2 mm
75x75x75 mm
17.50.2.1
17.50.2.1 Sand cast iron S&S
S&S as
as per
per IS - 1729 each 575.45
17.50.2.2 Sand cast iron S&S
S&S as
as per
per IS - 3989 each 575.45
17.50.2.3 Hubless centrifugally cast
Hubless centrifugally cast (spun)
(spun) iron epoxy
iron epoxy
inside&& outside as
coated inside as per IS:15905 each 401.90
17.51
17.51 Providing and fixing
Providing and fixing double
double unequal
unequal invert
invert branch of required
branch of degree :
required degree:
17.51.1
17.51.1 mm
100x100x75x75 mm
17.51.1.1
17.51.1.1 Sand cast iron S&S
S&S as
as per
per IS
IS - 1729 each 1011.05
17.51.1.2 Sand cast iron S&S
S&S as
as per
per IS
IS - 3989 each 1274.25
17.52 Providing and fixing
Providing and fixing single
single unequal
unequal plain
plain invert
invert branch of required
branch of degree:
required degree:
17.52.1
17.52.1 mm
100x100x75 mm
17.52.1.1
17.52.1.1 Sand cast iron S&S
S&S as per IS
as per IS - 1729 each 804.80
17.52.1.2 Sand cast iron S&S
S&S as per IS
as per IS - 3989 each 996.85
17.52.1.3 Hubless
Hubless centrifugally
centrifugally cast
cast (spun)
(spun) iron epoxy
iron epoxy
inside&& outside as
coated inside as per IS:15905 each 658.25
17.53 Providing
Providing and fixing sand
and fixing sand cast
cast iron
iron S&S off sets
S&S off as per
sets as per IS:
IS: 1729
1729
17.53.1
17.53.1 76
76 mm off sets
mm offsets
17.53.1.1
17.53.1.1 With 75 mm dia
75 mm dia pipe each 376.25
17.53.1.2 With 100
100 mm
mm dia
dia pipe each 603.90
17.53.2 114
114 mm off sets
mm off sets
17.53.2.1
17.53.2.1 With 75 mm
mm dia
dia pipe each 527.35
17.53.2.2 With 100
100 mm
mm dia
dia pipe each 648.30

272
272 SUB HEAD:: 17.0 SANITARY
SUB SANITARY INSTALLATIONS
Code No Description Unit Rate
17.53.3 152
152 mm off sets
mm offsets
17.53.3.1
17.53.3.1 With 75 mm
mm dia
dia pipe each 619.90
17.53.3.2 With 100
100 mm
mm dia
dia pipe each 769.25
17.53A Providing and fixing
Providing and fixing Hubless
Hubless centrifugally
centrifugally cast
cast iron offsets epoxy
iron offsets epoxy coated
coated
inside&& outside as
inside as per IS:15905
17.53A.1 65
17.53A.1 65 mm offsets
mm offsets
17.53A.1.1 With 100 mm
17.53A.1.1 mm dia
dia pipe each 547.00
17.53A.1.2 With 75 mm mm dia
dia pipe each 454.50
17.54 Providing
Providing and fixing sand
and fixing sand cast
cast iron
iron S&S
S&S off sets as
off sets as per
per IS: 3989 :
IS: 3989:
17.54.1
17.54.1 75
75 mm off sets
mm offsets
17.54.1.1
17.54.1.1 With 75 mm
mm dia
dia pipe each 418.95
17.54.2 150
150 mm off sets
mm offsets
17.54.2.1
17.54.2.1 With 75 mm
mm dia
dia pipe each 585.55
17.54.2.2 With 100 mmmm dia
dia pipe each 734.95
17.54A Providing
Providing and fixing Hubless
and fixing centrifugally cast
Hubless centrifugally cast iron
iron offsets epoxy coated
offsets epoxy coated
inside&& outside as
inside as per IS:15905
17.54A.1 130
17.54A.1 130 mm offsets
mm offsets
17.54A.1.1 With 100
17.54A.1.1 100 mm
mm dia
dia each 632.65
17.54A.1.2 With 75 75 mm
mm dia
dia each 465.90
17.55 Providing
Providing and fixing door
and fixing door piece,
piece, insertion
insertion rubber washer 3 mm
rubber washer3 thick, bolts
mm thick, bolts
&& nuts complete
complete::
17.55.1
17.55.1 100 mm
100 mm
17.55.1.1
17.55.1.1 Sand cast iron S&S
S&S as
as per
per IS - 1729 each 783.45
17.55.1.2 Sand cast iron S&S
S&S as
as per
per IS - 3989 each 683.85
17.55.2 75 mm
75 mm
17.55.2.1
17.55.2.1 Sand cast iron S&S
S&S as
as per
per IS - 1729 each 501.45
17.55.2.2 Sand cast iron S&S
S&S as
as per
per IS - 3989 each 537.00
17.56 Providing and fixing
Providing and fixing terminal
terminal guard:
guard :
17.56.1
17.56.1 100 mm
100 mm
17.56.1.1
17.56.1.1 Sand cast iron S&S
S&S as per IS
as per IS - 1729 each 442.00
17.56.1.2 Sand cast iron S&S
S&S as per IS
as per IS - 3989 each 506.00
17.56.1.3 Hubless
Hubless centrifugally cast (spun)
centrifugally cast (spun) iron epoxy
iron epoxy
inside&& outside as
coated inside as per IS:15905 each 427.80
17.56.2 75 mm
75 mm
17.56.2.1
17.56.2.1 Sand cast iron S&S
S&S as per IS
as per IS - 1729 each 340.70
17.56.2.2 Sand cast iron S&S
S&S as per IS
as per IS - 3989 each 404.75
17.57 Providing
Providing and fixing collar:
and fixing collar :
17.57.1
17.57.1 100 mm
100 mm
17.57.1.1
17.57.1.1 Sand cast iron S&S
S&S as per IS
as per IS - 1729 each 463.35
17.57.1.2 Sand cast iron S&S
S&S as per IS
as per IS - 3989 each 513.15
17.57.2 75 mm
75 mm
17.57.2.1
17.57.2.1 S&S as
Sand cast iron S&S per IS
as per IS - 1729 each 305.15
17.57.2.2 S&S as
Sand cast iron S&S per IS
as per IS - 3989 each 362.05

SUB HEAD:: 17.0 SANITARY


SUB SANITARY INSTALLATIONS 273
Code No Description Unit Rate
17.57A Providing and fixing
Providing and fixing shielded
shielded coupling for Hubless
coupling for centrifugally cast
Hubless centrifugally cast iron
iron
pipe
17.57A.1
17.57A.1 100 mm
100 mm dia
17.57A.1.1
17.57A.1.1 SS 304 grade coupling with EPDM rubber
SS 304
gasket each 432.05
17.57A.2 75 mm
75 mm dia
dia
17.57A.2.1
17.57A.2.1 SS 304
SS 304 grade coupling with EPDM rubber
gasket each 389.05
17.58 Providing
Providing lead
lead caulked joints to
caulked joints to sand
sand cast
cast iron/centrifugally
iron/centrifugally cast
cast (spun)
(spun) iron
iron
pipes and fittings
pipes and fittings ofof diameter
diameter::
17.58.1
17.58.1 100 mm
100 mm each 622.50
17.58.2 75 mm
75 mm each 526.25
17.58.3 50 mm
50 mm each 423.15
17.59 Providing
Providing and fixing M.S.
and fixing M.S. stays
stays and
and clamps for sand cast
clamps forsand cast iron/ centrifugally
iron/ centrifugally
cast
cast (spun)
(spun) iron
iron pipes
pipes ofof diameter:
diameter :
17.59.1
17.59.1 100 mm
100 mm each 139.70
17.59.2 75 mm
75 mm each 90.30
17.59.3 50 mm
50 mm each 81.85
17.60 Providing
Providing and fixing trap
and fixing trap of self cleansing
of self cleansing design
design with
with screwed
screwed down
down oror
hinged grating with or without vent arm arm complete, including cost of cutting
and making
and good thewalls
making good the walls and floors :
and floors:
17.60.1
17.60.1 100 mm
100 mm inlet and 100 mm
and 100 mm outlet
17.60.1.1
17.60.1.1 S&S as
Sand cast iron S&S as per
per IS: 3989 each 1996.50
17.60.1.2 S&S as
Sand Cast Iron S&S as per
per IS: 1729 each 1683.55
17.60.1.3 Hubless centrifugally cast
Hubless centrifugally cast (spun)
(spun) iron
iron epoxy
epoxy
inside&& outside as
coated inside as per IS:15905 each 854.55
17.60.2 100 mm
100 mm inlet and 75 mm
and 75 mm outlet
17.60.2.1
17.60.2.1 S&S as
Sand cast iron S&S as per
per IS - 3989 each 1975.15
17.60.2.2 S&S as
Sand Cast Iron S&S as per
per IS- 1729 each 1558.35
17.60.2.3 Hubless centrifugally cast
Hubless centrifugally cast (spun)
(spun) iron epoxy
iron epoxy
inside&& outside as
coated inside as per IS:15905 each 591.40
17.61
17.61 Cutting chases in brick masonry walls forfollowing
for following diameter sand cast iron/
centrifugally cast
centrifugally cast (spun)
(spun) iron
iron pipes and making
pipes and making good the same with
good thesame with cement
cement
concrete1 :3:6((11 cement
concrete 1:3:6 cement::3 3 coarse sand :6 graded stone aggregate 12.5
mm
mm nominal size), including
nominal size), including necessary
necessary plaster and pointing
plaster and pointing in
in cement
cement
mortar
mortar11:4
:4 (1
(1 cement
cement:4: 4 coarse
coarse sand)
sand)::
17.61.1
17.61.1 100 mm
100 mm dia metre 713.20
17.61.2 75 mm
75 mm dia metre 513.25
17.61.3 50 mm
50 mm dia metre 336.00
17.62 Painting C.I. cistern with bitumastic or any
any other anti-corrosive paint inside
and
and white paint overa
over a coat of zinc chromate yellow primer (of (ofapproved
approved
quality ) on
quality) on the
the outside
outside surface
surface of the cistern,
of the flush pipe,
cistern, flush pipe, other fittings, etc.
other fittings, etc.
complete fornew
for new work. each 1020.60
17.63 Re-painting C.I. cistern with bitumastic or any any other anti-corrosive paint
inside and white
inside and white paint on the
paint on the outside
outside surface of the
surface of the cistern, flush pipe,
cistern, flush pipe,
other fittings,
other fittings, etc.
etc. complete,
complete, including
including polishing of wooden
polishing of wooden seat
seat and
and lid
lid and
and
cleaning of W.C. pan with acid wherever necessary.
necessary. each 673.70

274 SUB HEAD:: 17.0 SANITARY


SUB SANITARY INSTALLATIONS
Code No Description Unit Rate
17.64 Repainting C.I. cistern with synthetic enamel paint of approved colour,
brand
brand andand manufacture
manufacture on the outside
on the outside surface of cistern,
surface of flush pipe,
cistern, flush pipe, other
other
fittings etc.
fittings etc. complete.
complete. each 292.55
17.65 Painting sand cast
Painting sand cast iron/ centrifugally cast
iron/ centrifugally cast (spun)
(spun) iron soil, waste
iron soil, waste vent
vent pipes
pipes
and fittings with
and fittings with two
two coats
coats of
of synthetic
synthetic enamel
enamel paint
paint of any colour
of any colour such
such as
as
chocolate
chocolate grey,
grey, or
or buff
buff etc. over a coat
etc. overa of primer
coat of primer (of approved quality)
(ofapproved quality) for
for
new work:
new work :
17.65.1
17.65.1 100 mm
100 mm diameter pipe metre 82.80
17.65.2 75 mm
75 mm diameter pipe metre 62.95
17.66 Repainting sand cast
Repainting sand cast iron/ centrifugally cast
iron/ centrifugally cast iron
iron (spun)
(spun) iron, soil, waste,
iron, soil, waste,
vent pipes
vent and fittings
pipes and fittings with
with one
one coat
coat ofsynthetic
of synthetic enamel
enamel paint of any
paint of any colour
colour
such as chocolate,
such as chocolate, grey
grey or
or buff
buff etc
etc::
17.66.1
17.66.1 100 mm
100 mm diameter pipe metre 39.50
17.66.2 75 mm
75 mm diameter pipe metre 29.55
17.67 Repainting bath tub of size 1700x730x430 mm mm with enamel paint. each 804.30
17.68 Providing
Providing and fixing vitreous
and fixing vitreous china
china dual
dual purpose closet suitable
purpose closet for use
suitable for as
use as
squatting
squatting pan
pan oror European
European typetype water
water closet
closet (Anglo
(Anglo Indian W.C pan)
Indian W.C with
pan) with
seat
seat&& lid fixed with
lid fixed with C.P.
C.P. brass
brass hinges and rubber
hinges and rubber buffers,
buffers, 10
10 litre
litre low
low level
level
flushing cistern
flushing with fitting
cistern with fitting and
and brackets, 40 mm
brackets, 40 flush bend,
mm flush bend, 2020 mm over
mm over
flow pipe,
flow with specials
pipe, with specials of of standard
standard make
make and
and mosquito
mosquito proof
proof coupling
coupling
of
of approved
approved municipal design complete,
municipal design complete, including
including painting of fittings
painting of fittings and
and
brackets,
brackets, cutting
cutting and
and making
making goodgood thewalls
the walls and floors wherever
and floors wherever required:
required:
17.68.1
17.68.1 White vitreous china dual purpose WC pan with white solid
WC pan
plastic
plastic seat and lid
seat and with white
lid with white vitreous
vitreous china flushing cistern
china flushing cistern
and C.P.
and flush bend.
C.P. flush bend. each 11847.65
17.69 Providing and fixing
Providing and fixing PTMT Waste Coupling
PTMT Waste for wash
Coupling for wash basin and sink,
basin and sink, of
of
approved quality and
and colour.
17.69.1
17.69.1 Waste coupling 3131 mm
mm dia of 79
79 mm
mm length and
and 62 mm breadth
62 mm
weighing not
not less than 45
45 gms
gms each 115.30
17.69.2 Waste coupling 38 mm dia of 83
38 mm mm length and
83 mm 77 mm
and 77 mm
breadth, weighing not less than 60
60 gms
gms each 122.40
17.70 Providing
Providing and fixing PTMT
and fixing PTMT Bottle Trap forWash
Bottle Trap for Wash basin and sink.
basin and sink.
17.70.1
17.70.1 Bottle trap 31
31 mmmm single piece moulded with height of 270 270
mm,
mm, effective
effective length of tail
length of tail pipe 260 mm
pipe 260 from the
mm from the centre of the
centre of the
waste coupling, 77 77 mm
mm breadth with 25 25 mm
mm minimum water
seal, weighing not less than 260 260 gms
gms each 367.10
17.70.2 Bottle trap 38
38 mmmm single piece moulded with height of 270 270
mm,
mm, effective
effective length of tail
length of tail pipe
pipe 260
260 mm from the
mm from the centre of the
centre of the
waste coupling, 77 77 mm
mm breadth with 25 mm minimum water
25 mm
seal, weighing not less than 263 263 gms
gms each 375.65
17.71
17.71 Providing and fixing
Providing and fixing PTMT
PTMT liquid
liquid soap container 109
soap container 109 mm wide, 125
mm wide, 125 mm
mm
and 112
high and 112 mm
mm distance from wall of standard shape with bracket of the
same
same materials with snap
materials with snap fittings
fittings of
of approved
approved quality
quality and
and colour, weighing
colour, weighing
not less than 105
105 gms. each 168.35
17.72 Providing and fixing
Providing and fixing PTMT towel ring
PTMT towel trapezoidal shape
ring trapezoidal shape 215
215 mm
mm long, 200
long, 200
mm wide with minimum distances of 37
mm 37 mm
mm from wall face with concealed
fittings arrangement
fittings arrangement of approved quality
ofapproved quality and
and colour, weighing not
colour, weighing not less than
less than
88 gms.
88 each 231.95
17.73 Providing and fixing
Providing and fixing PTMT towel rail
PTMT towel rail complete with brackets
complete with fixed to
brackets fixed to
wooden cleats
wooden cleats with
with CP
CP brass
brass screws with concealed
screws with concealed fittings
fittings arrangement
arrangement
ofapproved
of approved quality and
and colour.

SUB HEAD:: 17.0 SANITARY


SUB SANITARY INSTALLATIONS 275
Code No Description Unit Rate
17.73.1
17.73.1 450
450 mm mm long towel rail with total length of 495 495 mm,mm, 78 78 mmmm
wide and
wide effective height
and effective height of of 88
88 mm, weighing not
mm, weighing not less than
less than
170 gms
170 gms each 673.40
17.73.2 600
600 mm mm long towel rail with total length of 645 645 mm,
mm, width 78 78
mm
mm and and effective
effective height
height of of 88
88 mm, weighing not
mm, weighing not less than 190
less than 190
gms. each 708.95
17.74 Providing
Providing and fixing PTMT
and fixing PTMT shelfshelf 440440 mm mm long,
long, 124
124 mm width and
mm width and 36 36 mmmm
height of approved quality and and colour, weighing not not less than 300 300 gms. each 713.20
17.75 Providing
Providing and fixing PTMT
and fixing PTMT 15 15mm mm Urinal spreader size
Urinal spreader size 95x69x100
95x69x100 mm mm
with 1/2”
with 1/2” BSP thread and
BSP thread and shapes,
shapes, weighing
weighing not not less than 60
less than 60 gms.
gms. each 107.20
17.76 Providing
Providing and fixing PTMT
and fixing PTMT urinal
urinal cock of approved quality
cock ofapproved quality andand colour.
colour.
17.76.1
17.76.1 15 mm
15 mm nominal bore, 80 80 mmmm long, 42 42 mm mm high and and 30 30 mmmm
wide with BSP BSP female threads weighing not not less than 48 gms
48 gms each 175.40
17.77 Providing
Providing and and fixing
fixing M.S.
M.S. holder
holder bat bat clamp
clamp of of approved
approved design design to to sand
sand
cast
cast iron/
iron/ cast
cast ironiron (spun)
(spun) pipes comprising of
pipes comprising of M.S.
M.S. flatflat brackets
brackets made made of of
50x5
50x5 mm mm flatflat of specified shape,
of specified shape, projecting
projecting 75 75 mm outside the
mm outside the wall
wall surface
surface
and fixed on
and fixed on wall
wall with
with 4nos,6
4nos, 6 mm mm dia dia expansion
expansion hold fasteners, including
hold fasteners, including
drilling necessary holes in brick wall/ CC/ CC/ RCC RCC surface and and the cost of
bolts etc. The
bolts etc. The pipes
pipes shall
shall be fixed to
be fixed to the
the already
already fixedfixed brackets
brackets with with thethe
help
help of of 30
30 mm mm x1.6x1.6 mm galvanised M.S.
mm galvanised flats of
M.S. flats of specified
specified shapeshape and and of of
total length
total length 420 420 mm mm and and shall
shall be fixed with
be fixed with M.S.
M.S. nuts,
nuts, bolts,
bolts,& & washers
washers of of
size 25x6 mm, mm, one bolts on on each side of the pipe.
17.77.1
17.77.1 Total bracket length 580 580 mm mm of approved shape and design
(for
(for single
single 100 100 mmmm diadia pipe)
pipe) each 304.05
17.77.2 Total bracket length 810 810 mm mm of approved shape and design
(for two 100
(for two 100 mmmm dia dia pipes)
pipes) each 378.10
17.77.3 Total bracket length 1040 mm mm ofapproved
of approved shape and design
(for three 100
(for three 100 mm mm diadia pipes)
pipes) each 451.90
17.78 Providing
Providing and and fixing
fixing white
white vitreous
vitreous chinachina extended
extended wall wall mounting
mounting water water
closet of size 780x370x690 mm mm ofapproved
of approved shape including providing providing&&
fixing white
fixing white vitreous
vitreous chinachina cistern
cistern withwith dual flush fitting,
dual flush fitting, of of flushing
flushing capacity
capacity
33 litre/
litre/6 6 litre
litre (adjustable
(adjustable to to44 litre/
litre/8 8 litres),
litres), including
including seat seat cover, and cistern
cover, and cistern
fittings, nuts,
fittings, nuts, bolts
bolts and gasket etc
and gasket etc complete.
complete. each 14999.15
17.79 Providing
Providing&& fixing fixing white
white vitreous
vitreous china
china waterwater less
less urinal
urinal of size 600
of size 600 xx 330330
xx 315
315 mm mm havinghaving antibacterial
antibacterial /germs /germs free free ceramic surface, fixed
ceramic surface, fixed withwith
cartridge having debris catcher and and hygiene seal. each 18088.45
17.80 Providing
Providing and and fixing
fixing white
white vitreous
vitreous china china battery
battery basedbased infrared sensor
infrared sensor
operated urinal of approx. size 610 610xx 390 390 xx 370370 mm mm having pre pre&& post
flushing with
flushing with water
water (250 (250 ml ml&& 500 500 ml consumption), having
ml consumption), water inlet
having water inlet
from back
from back side,side, including fixing to
including fixing to wall
wall with
with suitable
suitable brackets
brackets all all asas per
per
manufacturers
manufacturers specification
specification and and direction
direction of of Engineer-in-charge.
Engineer-in-charge. each 7979.20
17.81
17.81 Providing
Providing and fixing floor
and fixing floor mounted,
mounted, white white vitreous
vitreous china single piece,
china single piece,
double traps syphonic water closet of approved brand/make, shape, size
and pattern including integrated white vitreous china cistern of capacity
and
10
10 litre with dual
litre with dual flushing
flushing system,
system, including
including all fittings and
all fittings fixtures with
and fixtures with
seat cover, cistern
seat cover, fittings, nuts,
cistern fittings, nuts, bolts
bolts and gasket etc
and gasket etc including
including makingmaking
connection with the existing P/S P/S trap, complete in all respect as as per
directions of Engineer-in-Charge. each 18212.90

276
276 SUB HEAD:: 17.0 SANITARY
SUB SANITARY INSTALLATIONS
SUB HEAD
SUB HEAD:: 18.0
WATER SUPPLY
18.0 WATER SUPPLY

Code No Description Unit Rate


PE-AL-PE COMPOSITE PRESSURE PIPE
18.1
18.1 Providing
Providing and fixing Polyethelene-Aluminium-Polyethelene
and fixing Polyethelene-Aluminium-Polyethelene PE-AL-PEPE-AL-PE
Composite
Composite Pressure
Pressure Pipes conforming to
Pipes conforming to IS
IS:: 15450,
15450, U.V.
U.V. stabilized with
stabilized with
carbon black having thermal stability for hot & & cold water supply, capable
for hot
to withstand
to withstand temperature
temperature up to 80°C,
up to 80°C, including all special
including all special fittings
fittings of
of
(engineering plastic blend and
composite material (engineering and brass inserts wherever
required)
required) e.g. elbows, tees,
e.g. elbows, tees, reducers,
reducers, couplers
couplers&& connectors
connectors etc.,
etc., with
with
clamps at
at 1.00 metre spacing. This includes testing of joints complete as
per direction of the
the Engineer-in-charge.
INTERNAL WORK - EXPOSED ON
ON WALL
18.1.1
18.1.1 1216
1216 (16
(16 mm
mm OD)
OD) pipe
pipe metre 286.75
18.1.2 1620
1620 (20
(20 mm
mm OD)
OD) pipe
pipe metre 331.20
18.1.3 2025 (25
2025 mm OD)
(25mm OD) pipe
pipe metre 401.55
18.1.4 2532 (32
2532 mm OD)
(32mm OD) pipe
pipe metre 529.85
18.1.5 3240 (40
3240 mm OD)
(40mm OD) pipe
pipe metre 684.45
18.1.6 4050 (50
4050 mm OD)
(50mm OD) pipe
pipe metre 939.70
18.2 Providing
Providing and fixing Polyethelene-Aluminium-
and fixing Polyethelene-Aluminium- Polyethelene
Polyethelene PE-AL-PE
PE-AL-PE
Composite
Composite Pressure
Pressure Pipes conforming to
Pipes conforming to IS
IS:: 15450,
15450, U.V.
U.V. stabilized with
stabilized with
carbon black having thermal stability for hot & & cold water supply, capable
for hot
to withstand
to withstand temperature
temperature up to 80°C,
up to 80°C, including all special
including all special fittings
fittings of
of
(engineering plastic blend and
composite material (engineering and brass inserts wherever
required)
required) e.g. elbows, tees,
e.g. elbows, tees, reducers,
reducers, couplers
couplers&& connectors
connectors etc., with
etc., with
clamps atat 1.00 metre spacing. This includes the costs of cutting chases
and including testing of joints complete as per direction
direction of the
the engineer
in charge.
Concealed work, including cutting chases and making good thewall
the wall etc.
18.2.1
18.2.1 1216
1216 (16
(16 mm
mm OD)
OD) pipe
pipe metre 522.70
18.2.2 1620
1620 (20
(20 mm
mm OD)
OD) pipe
pipe metre 557.55
18.2.3 2025 (25
2025 mm OD)
(25mm OD) pipe
pipe metre 627.25
18.2.4 2532 (32
2532 mm OD)
(32mm OD) pipe
pipe metre 754.20
18.3 Providing
Providing and fixing Polyethelene-Aluminium-
and fixing Polyethelene-Aluminium- Polyethelene
Polyethelene PE-AL-PE
PE-AL-PE
Composite Pressure
Composite Pressure Pipes conforming to
Pipes conforming to IS
IS:: 15450,
15450, U.V.
U.V. stabilized with
stabilized with
carbon black having thermal stability for hot & & cold water supply, capable
for hot
to withstand
to withstand temperature
temperature up up toto 80°C,
80°C, including all special
including all special fittings
fittings of
of
composite material (engineering
(engineering plastic blend and and brass inserts wherever
required)
required) e.g. elbows, tees,
e.g. elbows, tees, reducers,
reducers, couplers
couplers&& connectors
connectors etc., with
etc., with
trenching, refilling
trenching, refilling and testing of
and testing joints complete
of joints complete as as per direction of
per direction the
of the
engineer in charge.
External work
18.3.1
18.3.1 1216
1216 (16
(16 mm
mm OD)
OD) pipe
pipe metre 263.20
18.3.2 1620 (20 mm OD ) pipe
1620 (20 mm OD ) pipe metre 289.10
18.3.3 2025 (25
2025 mm OD
(25mm OD )) pipe
pipe metre 340.85
18.3.4 2532 (32
2532 mm OD
(32mm OD )) pipe
pipe metre 435.20
18.3.5 3240
3240 (40 mm OD
(40mm OD )) pipe
pipe metre 544.55
18.3.6 4050 (50
4050 mm OD
(50mm OD )) pipe
pipe metre 799.80

SUB HEAD:: 18.0 WATER SUPPLY


SUB SUPPi.Y 279
Code No Description Unit Rate
PP-R PIPES
18.4 Providing and fixing3
Providing and fixing 3 layer
layer PP-R
PP-R (Poly
(Poly propylene
propylene Random copolymer)
Random copolymer)
pipes confirming to
pipes confirming to IS:15801,
IS:15801, UV stabilized && anti
UV stabilized anti -- microbial fusion
microbial fusion
welded, having thermal stability for hot & & cold water supply, including all
for hot
PP - R plain
PP -R plain& & brass threaded polypropylene
brass threaded polypropylene random fittings and
random fittings fixing
and fixing
the
the pipe with clamps at m spacing. This includes testing of joints
at 1.00 m
complete as per direction of Engineer-in-Charge.
Internal Exposed on walls
18.4.1
18.4.1 PN
PN -- 16
16 Pipe, 20 mm
Pipe, 20 mm OD
OD (SDR-7.4)
(SDR-7.4) metre 272.00
18.4.2 PN
PN -- 16
16 Pipe, 25 mm
Pipe, 25 mm OD
OD (SDR-7.4)
(SDR-7.4) metre 318.35
18.4.3 PN
PN -- 16
16 Pipe,
Pipe, 32
32 mm
mm OD
OD (SDR-7.4)
(SDR-7.4) metre 362.90
18.4.4 PN
PN -- 16
16 Pipe, 40 mm
Pipe, 40 mm OD
OD (SDR-7.4)
(SDR-7.4) metre 545.75
18.4.5 PN
PN -- 10
10 Pipe,
Pipe, 50
50 mm
mm OD
OD (SDR-11)
(SDR-11) metre 580.10
18.5 Providing and fixing3
Providing and fixing 3 layer
layer PP-R
PP-R (Poly
(Poly propylene
propylene Random copolymer)
Random copolymer)
pipes confirming to
pipes confirming to IS:15801,
IS:15801, UV stabilized && anti
UV stabilized anti -- microbial fusion
microbial fusion
welded, having thermal stability for hot
hot & & cold water supply, including all
PP - R plain
PP -R plain& & brass threaded polypropylene
brass threaded polypropylene random fittings and
random fittings and fixing
fixing
the
the pipe with clamps atat 1.00 m
m spacing. This includes the cost of cutting
chases and making good thesame
the same including testing of joints complete as
per direction of Engineer-in-Charge.
Concealed work,incIuding
work,including cutting chases and making good thewall
the wall etc.
18.5.1
18.5.1 PN
PN -- 16
16 Pipe, 20 mm
Pipe, 20 mm OD
OD (SDR-7.4)
(SDR-7.4) metre 477.85
18.5.2 PN
PN -- 16
16 Pipe, 25 mm
Pipe, 25 mm OD
OD (SDR-7.4)
(SDR-7.4) metre 515.20
18.5.3 PN
PN -- 16
16 Pipe,
Pipe, 32
32 mm
mm OD
OD (SDR-7.4)
(SDR-7.4) metre 561.45
18.6 Providing
Providing and and fixing3
fixing 3 layer
layer PP-R
PP-R (Poly
(Poly propylene
propylene Random
Random copolymer)
copolymer)
pipes confirming to
pipes confirming to IS:15801
IS:15801 UVUV stabilized
stabilized&& anti
anti -- microbial fusion welded,
microbial fusion welded,
having thermal stability for hot & & cold water supply, including all PP
for hot PP --R R
plain
plain& & brass threaded polypropylene
brass threaded polypropylene random fittings, including
random fittings, trenching,
including trenching,
refilling
refilling& & testing
testing of joints complete
of joints complete as as per direction of
per direction of Engineer-in-Charge.
Engineer-in-Charge.
External work
18.6.1
18.6.1 PN
PN -- 16
16 Pipe, 20 mm
Pipe, 20 mm OD
OD (SDR-7.4)
(SDR-7.4) metre 224.95
18.6.2 PN
PN -- 16
16 Pipe, 25 mm
Pipe, 25 mm OD
OD (SDR-7.4)
(SDR-7.4) metre 265.05
18.6.3 PN
PN -- 16
16 Pipe,
Pipe, 32
32 mm
mm OD
OD (SDR-7.4)
(SDR-7.4) metre 316.25
18.6.4 PN
PN -- 16
16 Pipe, 40 mm
Pipe, 40 mm OD
OD (SDR-7.4)
(SDR-7.4) metre 415.10
18.6.5 PN
PN -- 10
10 Pipe,
Pipe, 50
50 mm
mm OD
OD (SDR-11)
(SDR-11) metre 450.95
18.6.6 PN
PN -- 10
10 Pipe,
Pipe, 63
63 mm
mm OD
OD (SDR-11)
(SDR-11) metre 597.75
18.6.7 PN
PN -- 10
10 Pipe,
Pipe, 75
75 mm
mm OD
OD (SDR-11)
(SDR-11) metre 696.75
18.6.8 PN
PN -- 10
10 Pipe,
Pipe, 90
90 mm
mm OD
OD (SDR-11)
(SDR-11) metre 975.30
18.6.9 PN
PN -- 10
10 Pipe,
Pipe, 110
110 mm
mm OD
OD (SDR-11)
(SDR-11) metre 1301.35
18.6.10 PN
PN -- 10
10 Pipe,
Pipe, 160
160 mm
mm OD
OD (SDR-11)
(SDR-11) metre 2746.85
18.6A Providing and fixing
Providing and fixing PPR
PPR Unions
Unions
18.6A.1
18.6A.1 PPR
PPR Union 20mm
Union 20mm each 315.50
18.6A.2 PPR
PPR Union 25mm
Union 25mm each 334.00
18.6A.3 PPR
PPR Union 32mm
Union 32mm each 403.70
18.6A.4 PPR
PPR Union 40mm
Union 40mm each 543.10
18.6A.5 PPR
PPR Union 50mm
Union 50mm each 782.10

280
280 SUB HEAD:: 18.0 WATER SUPPLY
SUB SUPPLV
Code No Description Unit Rate
18.6A.6 PPR
PPR Union
Union 63mm
63mm each 913.00
18.6A.7 PPR
PPR Union
Union 75mm
75mm each 1684.05
C.P.V.C. PIPES
18.7 Providing and fixing
Providing and fixing Chlorinated
Chlorinated Polyvinyl
Polyvinyl Chloride
Chloride (CPVC)
(CPVC) pipes,
pipes, having
having
thermal stability
thermal stability for
for hot
hot & & cold water supply
cold water supply and all CPVC
and all CPVC plain
plain&& brass
brass
threaded fittings,
threaded fittings, including fixing the
including fixing the pipe with clamps
pipe with at 1.00
clamps at 1.00 mm spacing.
spacing.
This includes
This jointing of
includes jointing of pipes
pipes&& fittings
fittings with
with one
one step
step CPVC
CPVC solvent
solvent
cement and testing of joints complete as per direction of Engineer in
Charge.
Internal work - Exposed on wall
18.7.1
18.7.1 15 mm
15 mm nominal dia
dia Pipes metre 286.80
18.7.2 20 mm nominal dia
20 mm dia Pipes metre 335.00
18.7.3 25 mm nominal dia
25 mm dia Pipes metre 401.55
18.7.4 32 mm nominal dia
32 mm dia Pipes metre 518.75
18.7.5 40 mm nominal dia
40 mm dia Pipes metre 702.95
18.7.6 50 mm
50 mm nominal dia
dia Pipes metre 934.15
18.8 Providing
Providing and fixing Chlorinated
and fixing Chlorinated Polyvinyl
Polyvinyl Chloride
Chloride (CPVC)
(CPVC) pipes,
pipes,
having thermal stability
having thermal for hot
stability for hot & & cold water supply,
cold water supply, including all CPVC
including all CPVC
plain
plain& & brass threaded fittings
brass threaded fittings and
and fixing
fixing the
the pipe with clamps
pipe with clamps at at 1.00
1.00
m spacing. This
m spacing. This includes jointing of
includes jointing of pipes
pipes&& fittings
fittings with
with one
one step
step CPVC
CPVC
solvent cement and thecost
the cost of cutting chases and making good thesame the same
including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good thewalls
the walls etc.
18.8.1
18.8.1 15 mm
15 mm nominal dia
dia Pipes metre 497.80
18.8.2 20 mm nominal dia
20 mm dia Pipes metre 537.60
18.8.3 25 mm nominal dia
25 mm dia Pipes metre 627.25
18.8.4 32 mm
32 mm nominal dia dia Pipes metre 739.30
18.9 Providing and fixing
Providing and fixing Chlorinated
Chlorinated Polyvinyl
Polyvinyl Chloride
Chloride (CPVC)
(CPVC) pipes,
pipes, having
having
thermal stability
thermal stability for
for hot
hot & & cold
cold water
water supply
supply including all CPVC
including all CPVC plain
plain&&
brass threaded fittings
brass threaded fittings This
This includes jointing of
includes jointing of pipes
pipes&& fittings
fittings with
with one
one
step CPVC
step solvent cement,
CPVC solvent cement, trenching,
trenching, refilling
refilling& & testing
testing of
of joints
joints complete
complete
as per direction of Engineer in Charge.
External work
18.9.1
18.9.1 15 mm
15 mm nominal dia dia Pipes metre 244.70
18.9.2 20 mm nominal dia
20 mm dia Pipes metre 274.30
18.9.3 25 mm nominal dia
25 mm dia Pipes metre 355.40
18.9.4 32 mm
32 mm nominal dia
dia Pipes metre 438.60
18.9.5 40 mm nominal dia
40 mm dia Pipes metre 563.05
18.9.6 50 mm
50 mm nominal dia
dia Pipes metre 794.25
18.9.7 65 mm nominal dia
65 mm dia Pipes metre 1674.40
18.9.8 80 mm nominal dia
80 mm dia Pipes metre 2166.35
18.9.9 100 mm
100 mm nominal dia
dia Pipes metre 3271.70
18.9.10 150 mm
150 mm nominal dia
dia Pipes metre 6822.70
18.10 Providing and fixing
Providing and fixing G.I.
G.I. pipes complete with
pipes complete with G.I. fittings and
G.I. fittings and clamps,
clamps,
including cutting and
and making good thewalls
the walls etc.
Internal work - Exposed on wall

SUB HEAD:: 18.0 WATER SUPPLY


SUB SUPPi.Y 281
Code No Description Unit Rate
18.10.1
18.10.1 15 mm
15 mm dia nominal bore metre 366.40
18.10.2 20 mm dia nominal bore
20 mm metre 437.30
18.10.3 25 mm dia nominal bore
25 mm metre 551.70
18.10.4 32 mm dia nominal bore
32 mm metre 667.00
18.10.5 40 mm dia nominal bore
40 mm metre 811.90
18.10.6 50 mm dia nominal bore
50 mm metre 1048.35
18.11
18.11 Providing
Providing and fixing G.I.
and fixing G.I. Pipes complete with
Pipes complete with G.I. fittings and
G.I. fittings and clamps,
clamps,
including making good thewalls
the walls etc. concealed pipe, including painting with
anti corrosive bitumastic paint, cutting chases and making good thewall:
the wall :
18.11.1
18.11.1 15 mm
15 mm dia nominal bore metre 580.45
18.11.2 20 mm dia nominal bore
20 mm metre 635.20
18.12 Providing
Providing and fixing G.I.
and fixing G.I. pipes
pipes complete with G.I.
complete with fittings including
G.I. fittings including
trenching and
trenching and refilling etc.
refilling etc.
External work
18.12.1
18.12.1 15 mm
15 mm dia nominal bore metre 322.15
18.12.2 20 mm dia nominal bore
20 mm metre 368.60
18.12.3 25 mm dia nominal bore
25 mm metre 467.75
18.12.4 32 mm dia nominal bore
32 mm metre 540.30
18.12.5 40 mm dia nominal bore
40 mm metre 617.05
18.12.6 50 mm dia nominal bore
50 mm metre 762.15
18.12.7 65 mm dia nominal bore
65 mm metre 896.60
18.12.8 80 mm dia nominal bore
80 mm metre 1041.70
18.13 Making connection of of G.I. distribution branch with G.I. main offollowing
of following
sizes
sizes by
by providing
providing and fixing tee,
and fixing tee, including
including cutting and threading
cutting and threading the
the pipe
pipe
complete::
etc. complete
18.13.1
18.13.1 25
25 to 40 mm nominal bore
40 mm each 911.90
18.13.2 50
50 to 80 mm nominal bore
80 mm each 1785.35
18.14 Fixing water meter andand stop cock in G.I. pipe line including cutting andand
threading the pipe and
and making long screws etc. complete (cost of water
meter and stop
meter and stop cock
cock to
to be
be paid separately).
paid separately). each 812.30
BRASS FITTINGS
18.15 Providing and fixing
Providing and fixing brass
brass bib cock ofapproved
bib cock of approved quality:
quality :
18.15.1
18.15.1 15 mm
15 mm nominal bore each 353.25
18.15.2 20 mm nominal bore
20 mm each 379.20
18.16 Providing and fixing
Providing and fixing brass stop cock
brass stop cock ofapproved
of approved quality:
quality :
18.16.1
18.16.1 15 mm
15 mm nominal bore each 353.25
18.16.2 20 mm nominal bore
20 mm each 379.20
18.17 Providing
Providing and fixing gun
and fixing gun metal gate valve
metal gate valve with
with C.I. wheel of
C.I. wheel of approved
approved
quality (screwed
quality end) :
(screwed end):
18.17.1
18.17.1 25 mm nominal bore
25 mm each 622.40
18.17.1A 20 mm nominal bore
20 mm each 539.95
18.17.2 32 mm
32 mm nominal bore. each 689.60
18.17.3 40 mm nominal bore
40 mm each 826.10
18.17.4 50 mm
50 mm nominal bore each 1026.65

282
282 SUB HEAD:: 18.0 WATER SUPPLY
SUB SUPPLV
Code No Description Unit Rate
18.17.5 65 mm nominal bore
65 mm each 1742.15
18.17.6 80 mm nominal bore
80 mm each 2604.55
18.18 Providing
Providing and fixing ball
and fixing valve (brass)
ball valve (brass) of
of approved
approved quality,
quality, High or low
High or low
pressure, with plastic
pressure, with floats complete
plastic floats complete::
18.18.1
18.18.1 15 mm
15 mm nominal bore each 406.85
18.18.2 20 mm nominal bore
20 mm each 462.50
18.18.3 25 mm nominal bore
25 mm each 464.05
18.19 Providing
Providing and fixing gun
and fixing gun metal
metal non-
non- return valve of
return valve of approved
approved quality
quality
(screwed end) :
(screwed end):
18.19.1
18.19.1 25 mm nominal bore
25 mm
18.19.1.1
18.19.1.1 Horizontal each 591.40
18.19.1.2 Vertical
Vertical each 624.10
18.19.2 32 mm nominal bore
32 mm
18.19.2.1
18.19.2.1 Horizontal
Horizontal each 791.90
18.19.2.2 Vertical
Vertical each 850.25
18.19.3 40 mm nominal bore
40 mm
18.19.3.1
18.19.3.1 Horizontal
Horizontal each 952.60
18.19.3.2 Vertical
Vertical each 1134.70
18.19.4 50 mm nominal bore
50 mm
18.19.4.1
18.19.4.1 Horizontal
Horizontal each 1371.20
18.19.4.2 Vertical
Vertical each 1445.15
18.19.5 65 mm nominal bore
65 mm
18.19.5.1
18.19.5.1 Horizontal
Horizontal each 2448.05
18.19.5.2 Vertical
Vertical each 2291.55
18.19.6 80 mm nominal bore
80 mm
18.19.6.1
18.19.6.1 Horizontal
Horizontal each 3664.75
18.19.6.2 Vertical
Vertical each 3855.40
18.20 Providing
Providing and fixing brass
and fixing ferrule with
brass ferrule with C.I.
C.I. mouth cover including
mouth cover including boring
boring
and
and tapping the main
main::
18.20.1
18.20.1 15 mm
15 mm nominal bore each 329.30
18.20.2 20 mm nominal bore
20 mm each 380.00
18.20.3 25 mm nominal bore
25 mm each 486.80
18.21
18.21 Providing and fixing
Providing and fixing uplasticised
uplasticised PVC
PVC connection
connection pipe with brass
pipe with brass unions
unions::
18.21.1
18.21.1 30 cm
30 cm length
18.21.1.1
18.21.1.1 15 mm
15 mm nominal bore each 85.00
18.21.1.2 20 mm nominal bore
20 mm each 93.55
18.21.2 45 cm length
45 cm
18.21.2.1
18.21.2.1 15 mm
15 mm nominal bore each 97.75
18.21.2.2 20 mm nominal bore
20 mm each 119.05
18.22 Providing and fixing
Providing and fixing C.P.
C.P. brass
brass shower
shower rose with 15
rose with or 20
15 or 20 mm
mm inlet
inlet::
18.22.1
18.22.1 100 mm
100 mm diameter each 193.95
18.22.2 150 mm
150 mm diameter each 222.35

SUB HEAD:: 18.0 WATER SUPPLY


SUB SUPPi.Y 283
Code No Description Unit Rate
PIPES&& SPECIALS
C.I./DUCTILE IRON PIPES
18.23 Laying
Laying in
in position centrifugally cast
position centrifugally cast (spun)
(spun) iron
iron S&S
S&S or flanged pipes
or flanged pipes
(excluding cost of
(excluding cost of pipe).
pipe). quintal 361.65
18.24 Laying
Laying inin position
position S&S
S&S or or flanged
flanged C.I. special such
C.I. special such asas tees,
tees, bends,
bends, collars,
collars,
tapers and
tapers and caps etc.(excluding cost
caps etc.(excluding of specials).
cost of specials). quintal 661.85
18.25 Providing andand laying S&S S&S C.I. standard specials such as tees, bends,
collars, tapers, caps
collars, tapers, caps etc.
etc. (Heavy
(Heavy class):
class):
18.25.1
18.25.1 Up to 300
Up to 300 mm mm diadia quintal 6352.40
18.25.2 Over 300 mm mm dia
dia quintal 6352.40
18.26 Providing
Providing andand laying flanged C.I.
laying flanged standard specials
C.I. standard specials such
such as tees, bends,
as tees, bends,
collars, tapers, caps
collars, tapers, caps etc.,
etc., suitable for flanged
suitable for flanged jointing
jointing as
as per
per IS
IS:: 1538
1538::
18.26.1
18.26.1 Up to 300
Up to 300 mm mm diadia quintal 8913.15
18.26.2 Over 300 mm mm dia
dia quintal 8486.35
18.27 Providing
Providing andand laying S&S centrifugally
laying S&S centrifugally cast
cast (spun)
(spun) iron
iron pipes
pipes (Class
(Class LA)
LA)
conforming to :1536::
to IS :1536
18.27.1
18.27.1 100 mm
100 mm dia pipe metre 1423.10
18.27.2 125 mm
125 mm dia pipe metre 1729.35
18.27.3 150 mm
150 mm dia pipe metre 2037.00
18.27.4 200 mm dia pipe
200 mm metre 3406.85
18.27.5 250 mm dia pipe
250 mm metre 4639.80
18.27.6 300 mm
300 mm dia pipe metre 6128.65
18.27.7 350 mm
350 mm dia pipe metre 7343.80
18.27.8 400 mm dia pipe
400 mm metre 9701.00
18.27.9 450 mm dia pipe
450 mm metre 11714.85
18.27.10 500 mm
500 mm dia pipe metre 13728.75
18.27.11
18.27.11 600 mm dia pipe
600 mm metre 18636.45
18.28 Providing lead caulked joints to spun iron or or C.I. pipes and
and specials,
including testing of joints but
but excluding the cost of pig lead
lead::
18.28.1
18.28.1 100 mm
100 mm diameter pipe each 496.40
18.28.2 125 mm
125 mm diameter pipe each 737.50
18.28.3 150 mm
150 mm diameter pipe each 744.85
18.28.4 200 mm diameter pipe
200 mm each 990.20
18.28.5 250 mm diameter pipe
250 mm each 1237.80
18.28.6 300 mm
300 mm diameter pipe each 1488.80
18.28.7 350 mm
350 mm diameter pipe each 1513.60
18.28.8 400 mm diameter pipe
400 mm each 1993.75
18.28.9 450 mm diameter pipe
450 mm each 2238.45
18.28.10 500 mm
500 mm diameter pipe each 2366.45
18.28.11
18.28.11 600 mm diameter pipe
600 mm each 3211.40
18.29 pig lead at site of work.
Supplying pig quintal 29875.40
18.30 Providing flanged joints
Providing flanged joints to
to double
double flanged
flanged C.I./
C.I./ D.I.
D.I. pipes
pipes and
and specials,
specials,
including testing of joints:
joints :
18.30.1
18.30.1 80 mm
80 mm diameter pipe each 215.10

284
284 SUB HEAD:: 18.0 WATER SUPPLY
SUB SUPPLV
Code No Description Unit Rate
18.30.2 100 mm
100 mm diameter pipe each 332.00
18.30.3 125 mm
125 mm diameter pipe each 351.90
18.30.4 150 mm
150 mm diameter pipe each 387.40
18.30.5 200 mm diameter pipe
200 mm each 428.65
18.30.6 250 mm diameter pipe
250 mm each 596.65
18.30.7 300 mm diameter pipe
300 mm each 599.50
18.30.8 350
350 mmmm diameter pipe each 762.90
18.30.9 400
400 mmmm diameter pipe each 1066.80
18.30.10 450
450 mmmm diameter pipe each 1305.60
18.30.11
18.30.11 500
500 mmmm diameter pipe each 1437.80
18.30.12 600
600 mmmm diameter pipe each 1704.10
C.I. SLUICE VALVES/ FIRE HYDRANTS HYDRANTS&& FIXTURES
18.31
18.31 Providing and fixing
Providing and fixing C.I.
C.I. sluice valves (with
sluice valves (with cap)
cap) complete with bolts,
complete with bolts, nuts,
nuts,
rubber
rubber insertions
insertions etc.
etc. (the tail pieces
(the tail pieces ifif required will be
required will be paid separately) :
paid separately):
18.31.1
18.31.1 100 mm
100 mm diameter
18.31.1.1
18.31.1.1 Class I each 4791.20
18.31.1.2 Class II each 4985.85
18.31.2 125 mm
125 mm diameter
18.31.2.1
18.31.2.1 Class I each 5160.80
18.31.2.2 Class II each 5943.00
18.31.3 150 mm
150 mm diameter
18.31.3.1
18.31.3.1 Class I each 6966.55
18.31.3.2 Class II each 7312.40
18.31.4 200 mm diameter
200 mm
18.31.4.1
18.31.4.1 Class I each 13554.70
18.31.4.2 Class II each 14622.95
18.31.5 250 mm diameter
250 mm
18.31.5.1
18.31.5.1 Class I each 19566.55
18.31.5.2 Class II each 24623.50
18.31.6 300 mm
300 mm diameter
18.31.6.1
18.31.6.1 ClassI
Class I each 27059.30
18.31.6.2 Class II each 30203.00
18.32 Constructing masonry Chamber 30x30x50 cm inside, in brick work in
cm inside,
cement mortar
cement mortar 1:4
1:4 (1
(1 cement
cement :4 coarse sand)
:4 coarse sand) for
for stop
stop cock,
cock, with
with C.
C. I.I.
surface box
surface box 100x100 x75 mm
100x100 x75 mm (inside) with hinged
(inside) with hinged cover fixed in
cover fixed in reinforced
reinforced
cement concrete slab 1:1.5:3 mixmix (1
(1 cement: 1.5coarse
cement : 1.5 coarse sand:
sand :3 3 graded
stone aggregate
stone 20 mm
aggregate 20 mm nominal size), including
nominal size), including necessary excavation,
necessary excavation,
foundation concrete
foundation concrete 1:5:10
1:5:10((11 cement:5
cement : 5 fine
fine sand:
sand : 10 graded stone
10 graded stone
aggregate 40
aggregate 40 mm
mm nominal size ) and
nominal size) and inside
inside plastering with cement
plastering with cement mortar
mortar
1:3
1:3 (1 cement : 3 coarse
(1 cement:3 coarse sand)
sand) 1212 mm thick, finished
mm thick, finished witha
with a floating
floating coat
coat
of
of neat cement complete as per standard design:
design :
18.32.1
18.32.1 With common
With common burnt clay F.P.S.(non
burnt clay F.P.S.(non modular)
modular) bricks
bricks of class
of class
designation 7.5 each 1992.60

SUB HEAD:: 18.0 WATER SUPPLY


SUB SUPPi.Y 285
Code No Description Unit Rate
18.33 Constructing masonry Chamber 60x60x75 cm cm inside, in brick work in
cement
cement mortar
mortar11:4
:4 (1
(1 cement
cement::4 4 coarse sand) forsluice
coarse sand) for sluice valve,
valve, with
with C.I.
C.I.
surface boxbox 100
100 mm
mm top diameter, 160 mm
diameter, 160 mm bottom diameter and and 180180 mm
mm
deep
deep(( inside) with chained
inside) with chained lid and RCC
lid and top slab
RCC top slab11:1.5:3
:1.5:3 mix
mix (1 cement : 1.5
(1 cement: 1.5
coarse sand : 3 graded
coarse sand:3 graded stone aggregate 20
stone aggregate 20 mm
mm nominal
nominal size),
size), including
including
necessary
necessary excavation, foundation concrete
excavation, foundation concrete 1:5:10
1:5:10 (1
(1 cement
cement:5 : 5 fine
fine sand
sand
: 10 graded stone
10 graded stone aggregate
aggregate 40 40 mm
mm nominal
nominal size) and inside
size) and inside plastering
plastering
with cement
with cement mortar
mortar11:3:3 (1
(1 cement
cement::3 3 coarse
coarse sand)
sand) 1212 mm thick, finished
mm thick, finished
with a floating
witha floating coat of neat
coat of neat cement
cement complete
complete asas per standard design:
per standard design :
18.33.1
18.33.1 With common
With common burnt
burnt clayclay F.P.S.(non
F.P.S.(non modular)
modular) bricks of class
bricks of class
designation 7.5 each 10862.40
18.34 Constructing masonry Chamber 90x90x100 cm cm inside, in brick work in
cement
cement mortar
mortar11:4 :4 (1
(1 cement
cement::4 4 coarse sand) forsluice
coarse sand) for sluice valve,
valve, with
with C.I.
C.I.
surface box box 100
100 mm
mm top diameter,
diameter, 160 160 mm
mm bottom diameter and 180 mm
and 180 mm
deep
deep (inside) with chained
(inside) with chained lid and RCC
lid and RCC toptop slab
slab 1:1.5:3
1:1.5:3 mix
mix (1 cement : 1.5
(1 cement: 1.5
coarse sand : 3 graded
coarse sand:3 graded stone aggregate 20
stone aggregate 20 mm
mm nominal
nominal size),
size), including
including
necessary
necessary excavation, foundation concrete
excavation, foundation concrete 1:5:10
1:5:10 (1 (1 cement
cement:5 : 5 fine
fine sand
sand
: 10 graded stone
10 graded aggregate 40
stone aggregate 40 mmmm nominal
nominal sizesize)) and
and inside
inside plastering
plastering
with cement
with cement mortar
mortar11:3 :3 (1
(1 cement
cement::3 3 coarse
coarse sand)
sand) 12 12 mm thick, finished
mm thick, finished
with a floating
witha floating coat of neat
coat of neat cement
cement complete
complete as as per standard design:
per standard design :
18.34.1
18.34.1 With common
With common burnt
burnt clayclay F.P.S.(non
F.P.S.(non modular)
modular) bricks
bricks of
of class
class
designation 7.5 each 18896.70
18.35 Constructing masonry Chamber 120x120x100 cm cm inside,
inside, in brick work in
cement
cement mortar
mortar11:4 :4 (1
(1 cement
cement:4 : 4 coarse
coarse sand)
sand) forsluice
for sluice valve,
valve, with
with C.I.
C.I.
surface box box 100
100 mm
mm top diameter,
diameter, 160 160 mm
mm bottom diameter and 180 mm
and 180 mm
deep
deep(( inside) with chained
inside) with chained lid and RCC
lid and RCC toptop slab
slab11:1.5:3
:1.5:3 mix
mix (1 cement : 1.5
(1 cement: 1.5
coarse sand : 3 graded
coarse sand:3 graded stone aggregate 20
stone aggregate 20 mmmm nominal
nominal size),
size), including
including
necessary
necessary excavation, foundation concrete
excavation, foundation concrete 1:5:10
1:5:10 (1 (1 cement
cement:5 : 5 fine
fine sand
sand
: 10 graded stone
10 graded stone aggregate
aggregate 40 40 mmmm nominal
nominal size) and inside
size) and inside plastering
plastering
with cement
with cement mortar
mortar11:3 :3 (1
(1 cement
cement::3 3 coarse
coarse sand)
sand) 12 12 mm thick, finished
mm thick, finished
with a floating
witha floating coat of neat
coat of neat cement
cement complete
complete as as per standard design:
per standard design :
18.35.1
18.35.1 With common
With common burnt
burnt clayclay F.P.S.(non
F.P.S.(non modular)
modular) bricks
bricks of class
of class
designation 7.5 each 26163.40
18.36 Constructing masonry Chamber 60x60x75 cm, inside in brick work in
cement
cement mortar
mortar11:4:4 (1
(1 cement
cement::4 4 coarse sand) forfire
coarse sand) for fire hydrants,
hydrants, with with C.I.
C.I.
surface
surface box box 350x350
350x350 mm top and
mm top and 165165 mm
mm deep
deep(( inside) with chained
inside) with chained
lid and
and RCCRCC toptop slab 1:1.5:3 mix mix (1(1 cement
cement:: 1.5 1.5 coarse sand:
sand :3 3 graded
stone aggregate 20
stone aggregate 20 mm
mm nominal
nominal size),size), including
including necessary
necessary excavation,
excavation,
foundation concrete
foundation concrete 1:5:10
1:5:10 (1(1 cement
cement:: 5 5 finefine sand:10
sand:10 graded stone
graded stone
aggregate
aggregate 40 40 mmmm nominal size) and
nominal size) and inside
inside plastering with cement
plastering with cement mortar
mortar
11:3
:3 (1 cement :3 3 coarse
(1 cement: coarse sand)
sand) 12 12 mm thick, finished
mm thick, finished witha
with a floating
floating coat
coat
of neat cement complete as per standard design:
of design :
18.36.1
18.36.1 With common
With common burnt
burnt clayclay F.P.S.(non
F.P.S.(non modular)
modular) bricks
bricks of class
of class
designation 7.5 each 10354.95
18.37 Constructing masonry Chamber 60x45x50 cm
Constructing cm inside,
inside, in brick work in
cement
cement mortar
mortar11:4:4 (1 cement :4 4 coarse
(1 cement: coarse sand)
sand) forwater
for water meter
meter complete
complete
with C.I.
with double flap
C.I. double flap surface
surface box 400x200x200 mm
box 400x200x200 mm (inside) with locking
(inside) with locking
arrangement and and RCC
RCC toptop slab 1:1.5:3 mix
mix (1
(1 cement
cement:: 1.5
1.5 coarse sand
:33 graded
graded stone aggregate 20
stone aggregate 20 mm
mm nominal
nominal size),
size), including
including necessary
necessary
excavation, foundation concrete
excavation, foundation concrete 1:5:10
1:5:10((11 cement:5
cement : 5 fine
fine sand:10
sand:10 graded
graded
stone aggregate 40
stone aggregate 40 mm
mm nominal size) and
nominal size) and inside
inside plastering with cement
plastering with cement
mortar
mortar11:3:3 (1
(1 cement
cement:3: 3 coarse
coarse sand)
sand) 12
12 mm thick, finished
mm thick, finished witha
with a floating
floating
of neat cement complete as per standard design:
coat of design :
18.37.1
18.37.1 With common
With common burnt clay F.P.S.(non
burnt clay F.P.S.(non modular)
modular) bricks
bricks of class
of class
designation 7.5 each 9698.55

286
286 SUB HEAD:: 18.0 WATER SUPPLY
SUB SUPPLV
Code No Description Unit Rate
18.38 Painting
Painting G.I.
G.I. pipes and fittings
pipes and fittings with
with synthetic
synthetic enamel
enamel white
white paint with two
paint with two
overaa ready mixed priming coat, both of approved quality for new
coats over new
work:
work :
18.38.1
18.38.1 15 mm
15 mm diameter pipe metre 19.40
18.38.2 20 mm diameter pipe
20 mm metre 23.25
18.38.3 25 mm diameter pipe
25 mm metre 30.25
18.38.4 32 mm diameter pipe
32 mm metre 36.35
18.38.5 40 mm diameter pipe
40 mm metre 42.65
18.38.6 50 mm diameter pipe
50 mm metre 51.00
18.39 Repainting
Repainting G.I.
G.I. pipes and fittings
pipes and fittings with
with synthetic
synthetic enamel white paint
enamel white with
paint with
one coat of approved quality
one quality::
18.39.1
18.39.1 15 mm
15 mm diameter pipe metre 9.50
18.39.2 20 mm diameter pipe
20 mm metre 11.30
18.39.3 25 mm diameter pipe
25 mm metre 14.40
18.39.4 32 mm
32 mm diameter pipe metre 17.25
18.39.5 40 mm diameter pipe
40 mm metre 20.00
18.39.6 50 mm diameter pipe
50 mm metre 23.85
18.40 Painting
Painting G.I.
G.I. pipes
pipes and fittings with
and fittings with two
two coats
coats of
of anti-corrosive
anti-corrosive bitumastic
bitumastic
quality::
paint of approved quality
18.40.1
18.40.1 15 mm
15 mm diameter pipe metre 12.05
18.40.2 20 mm diameter pipe
20 mm metre 14.45
18.40.3 25 mm diameter pipe
25 mm metre 18.35
18.40.4 32 mm diameter pipe
32 mm metre 22.20
18.40.5 40 mm diameter pipe
40 mm metre 25.25
18.40.6 50 mm
50 mm diameter pipe metre 30.50
18.40.7 65
65 mm mm diameter pipe metre 37.85
18.40.8 80
80 mm mm diameter pipe metre 44.00
18.41
18.41 Providing and filling
Providing and filling sand
sand ofgrading
of grading zone
zoneVV orcoarser
or coarser grade,
grade, allround the
allround the
G.I. pipes in external work:
work :
18.41.1
18.41.1 15 mm
15 mm diameter pipe metre 154.45
18.41.2 20 mm diameter pipe
20 mm metre 156.55
18.41.3 25 mm diameter pipe
25 mm metre 160.70
18.41.4 32 mm diameter pipe
32 mm metre 164.90
18.41.5 40 mm diameter pipe
40 mm metre 167.00
18.41.6 50 mm diameter pipe
50 mm metre 173.25
18.41.7 65 mm diameter pipe
65 mm metre 273.45
18.41.8 80 mm diameter pipe
80 mm metre 281.80
18.41.9 100 mm
100 mm diameter pipe metre 298.50
18.41.10 150 mm
150 mm diameter pipe metre 444.60
18.42 Boring with 100
100 mm
mm diameter casing pipe forhand
for hand pump// tubewell,
tubewell, in all
soils except ordinary hard rocks requiring blasting, including removing the
casing pipe after the
the hand pump// tube well is lowered andand tested:
tested :
18.42.1
18.42.1 Up to 6 metres
Up to6 metres depth
depth metre 747.90
18.42.2 Beyond66 m
Beyond m and up to12 m depth
to 12 m metre 884.85
18.42.3 m and up to18
Beyond 12 m m depth
to 18 m metre 1025.95

SUB HEAD:: 18.0 WATER SUPPLY


SUB SUPPi.Y 287
Code No Description Unit Rate
18.43 Providing and placing
Providing and placing in
in position filters of
position filters of 40
40 mm diameter G.I.
mm diameter G.I. pipe with
pipe with
brass strainer of approved quality. metre 960.30
18.44 Providing
Providing and fixing to
and fixing to filter
filter and
and lowering to proper
lowering to proper levels 40 mm
levels 40 mm G.I.
G.I. pipe
pipe
fortube
for tube well including cleaning and and priming the tube well. metre 546.00
18.45 Providing and
and placing in position hand pump ofapproved
of approved quality for 40
40
mm diameter G.I. pipe complete with all accessories.
mm accessories. each 1321.65
18.46 Providing
Providing and fixing G.I.
and fixing G.I. Union
Union in
in G.I.
G.I. pipe
pipe including
including cutting and threading
cutting and threading
the pipe
the pipe and
and making
making long screws etc.
long screws etc. complete
complete (New work) :
(New work)
18.46.1
18.46.1 15 mm
15 mm nominal bore each 318.35
18.46.2 20
20 mmmm nominal bore each 346.80
18.46.3 25 mm nominal bore
25 mm each 439.25
18.46.4 32 mm nominal bore
32 mm each 489.05
18.46.5 40 mm nominal bore
40 mm each 631.30
18.46.6 50 mm nominal bore
50 mm each 823.80
18.46.7 65 mm nominal bore
65 mm each 1136.80
18.46.8 80 mm nominal bore
80 mm each 1207.95
18.47 Providing and fixing
Providing and fixing G.I.
G.I. Union
Union in
in existing
existing G.I.
G.I. pipe
pipe line, cutting and
line, cutting and
threading the
threading the pipe
pipe and
and making
making long screws, including
long screws, excavation, refilling
including excavation, refilling
the
the earth or cutting of wall and
and making good thesame
the same complete wherever
required::
required
18.47.1
18.47.1 15 mm
15 mm nominal bore each 829.45
18.47.2 20 mm nominal bore
20 mm each 857.85
18.47.3 25 mm nominal bore
25 mm each 950.35
18.47.4 32 mm nominal bore
32 mm each 1000.15
18.47.5 40
40 mmmm nominal bore each 1142.40
18.47.6 50 mm
50 mm nominal bore each 1520.80
18.47.7 65
65 mmmm nominal bore each 1833.75
18.47.8 80
80 mmmm nominal bore each 1904.90
18.48 Providing
Providing and and placing
placing onon terrace
terrace (at all floor
(at all floor levels)
levels) polyethylene water
polyethylene water
storage tank, IS :: 12701 12701 marked, with cover and and suitable locking
arrangement and
arrangement and making
making necessary
necessary holes for inlet,
holes for outlet and
inlet, outlet and overflow
overflow
pipes
pipes but without fittings
but without fittings and
and the
the base support fortank.
base support for tank. per litre 11.00
18.48A Providing
Providing andand fixing
fixing rectangular
rectangular high density polyethylene
high density water storage
polyethylene water storage
loft tank with cover, conforming to ISI:: 12701, colour of opaque white or
to ISI
as
as approved by Engineer-in-charge. The The rate includes making necessary
holes for inlet, outlet
holes forinlet, outlet& & over flow pipes.
over flow The base
pipes. The base support
support Including fittings
Including fittings
& & fixtures
fixtures for
for tank
tank shall
shall be
be paid separately.
paid separately. per litre 11.00
C.P. BRASS FITTINGS
18.49 Providing
Providing and fixing C.P.
and fixing C.P. brass
brass bib
bib cock
cock ofof approved
approved quality
quality conforming
conforming
to IS:8931::
to IS:8931
18.49.1
18.49.1 15 mm
15 mm nominal bore each 506.80
18.50 Providing
Providing and fixing C.P.
and fixing C.P. brass
brass long
long nose
nose bib cock of
bibcock of approved
approved quality
quality
conforming to
to IS standards and
and weighing not
not less than 810
810 gms.
18.50.1
18.50.1 15 mm
15 mm nominal bore each 820.70

288
288 SUB HEAD:: 18.0 WATER SUPPLY
SUB SUPPLV
Code No Description Unit Rate
18.51
18.51 Providing and fixing
Providing and fixing C.P.
C.P. brass
brass long
long body
body bib cock of
bibcock of approved
approved quality
quality
conforming to
to IS standards and
and weighing not
not less than 690
690 gms.
18.51.1
18.51.1 15 mm
15 mm nominal bore each 798.95
18.52 Providing and fixing
Providing and fixing C.P.
C.P. brass
brass stop
stop cock
cock (concealed)
(concealed) of standard design
of standard design
and of
and of approved make conforming to IS:8931.
18.52.1
18.52.1 15 mm
15 mm nominal bore each 670.45
18.53 Providing and fixing
Providing and fixing C.P.
C.P. brass
brass angle valve for
angle valve for basin
basin mixer and geyser
mixer and geyser
points of approved quality conforming to IS:8931
to IS:8931
18.53.1
18.53.1 15 mm
15 mm nominal bore each 574.30
18.53A Providing and fixing
Providing and fixing C.P.
C.P. Brass
Brass extension
extension nipple
nipple (size
(size 15
15 mm
mm x x 50
50 mm) of
mm) of
approved make andand quality as per direction of Engineer-in-charge.
as per each 74.80
PTMT FITTINGS
18.54 Providing
Providing and fixing PTMT
and fixing PTMT bib cock ofapproved
bibcock of approved quality and colour.
quality and colour.
18.54.1
18.54.1 15 mm
15 mm nominal bore, 86 mm long, weighing not less than
86 mm
88
88 gms
gms each 125.60
18.54.2 15 mm
15 mm nominal bore, 122
122 mm
mm long, weighing not
not less than
99
99 gms
gms each 161.20
18.54.3 15 mm
15 mm nominal bore, 165
165 mm
mm long, weighing not
not less than
110 gms
gms each 176.85
18.54.4 15 mm
15 mm nominal bore, 90 mm long, weighing not less than
90 mm
93
93 gms
gms each 196.75
18.55 Providing and fixing
Providing and fixing PTMT
PTMT stop cock ofapproved
stop cock of approved quality and colour.
quality and colour.
18.55.1
18.55.1 15 mm
15 mm nominal bore, 86 mm long, weighing not less than
86 mm
88
88 gms
gms each 118.50
18.55.2 20 mm nominal bore, 89
20 mm mm long, weighing not less than
89 mm
88
88 gms
gms each 129.90
18.55.3 Concealed stop cock, 15 15 mm
mm nominal bore, 108 108 mm
mm long,
not less than 108
weighing not 108 gms
gms each 218.10
18.56 Providing and fixing
Providing and fixing PTMT
PTMT pillar cock ofapproved
pillar cock of approved quality
quality and
and colour.
colour.
18.56.1
18.56.1 15 mm
15 mm nominal bore, 107 107 mm
mm long, weighing not not less than
110 gms
gms each 208.45
18.56.2 15
15 mm
mm nominal
nominal bore,
bore, 125
125 mm
mm long foam flow,
long foam flow, weighing
weighing not
not
less than 120
120 gms
gms each 224.10
18.57 Providing and fixing
Providing and fixing PTMT,
PTMT, push
push cock of approved quality
cock ofapproved quality and
and colour.
colour.
18.57.1
18.57.1 15 mm
15 mm nominal bore, 98 mm long, weighing not
98 mm not less than
75 gms
75 gms each 112.80
18.57.2 15 mm
15 mm nominal bore, 80 mm long, weighing not
80 mm not less than
46
46 gms
gms each 95.75
18.58 Providing and fixing
Providing and fixing PTMT grating of
PTMT grating of approved
approved quality and colour.
quality and colour.
18.58.1
18.58.1 Circular type
18.58.1.1
18.58.1.1 100 mm
100 mm nominal dia
dia each 37.60
18.58.1.2 125 mm
125 mm nominal dia
diawith
with 25 mm waste hole
25 mm each 51.85
18.58.2 Rectangular type with openable circular lid
18.58.2.1
18.58.2.1 150 mm
150 mm nominal size square 100 mm mm
diameter of
of the inner hinged round grating each 196.95

SUB HEAD:: 18.0 WATER SUPPLY


SUB SUPPi.Y 289
289
Code No Description Unit Rate
AIR
AIR VALVE&
VALVE & WATER METER (BULK TYPE)
18.59 Providing
Providing and fixing C.I.
and fixing double acting
C.I. double acting air valve of
air valve of approved
approved quality
quality with
with
bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if
required will be
required will be paid
paid separately)
separately)::
18.59.1
18.59.1 50 mm dia
50 mm each 5748.80
18.59.2 80 mm dia
80 mm each 6993.60
18.59.3 100 mm
100 mm dia each 8893.00
18.60 Providing and fixing
Providing and fixing enclosed type water
enclosed type water meter
meter (bulk type) conforming
(bulk type) to
conforming to
IS:: 2373 and tested by by Municipal Board complete with bolts, nuts, rubber
insertions etc. (The
insertions etc. tail pieces
(The tail pieces ifif required will be
required will be paid separately) :
paid separately):
18.60.1
18.60.1 80
80 mmmm dia nominal bore each 3627.65
18.60.2 100 mm
100 mm dia nominal bore each 5468.35
18.60.3 150 mm
150 mm dia nominal bore each 8408.80
18.60.4 200
200 mmmm dia nominal bore each 9043.30
18.61
18.61 Providing and fixing
Providing and fixing C.I.
C.I. dirt
dirt box
box strainer for bulk
strainer for type water
bulk type water meter with
meter with
nuts, bolts, rubber insertions etc. complete conforming to IS IS:: 2373:
2373 :
18.61.1
18.61.1 80
80 mmmm dia each 4623.50
18.61.2 100 mm
100 mm dia each 7460.00
18.61.3 150 mm
150 mm dia each 9433.10
18.61.4 200
200 mmmm dia each 12927.10
18.62 Providing and fixing
Providing and fixing PTMT
PTMT Ball cock ofapproved
Ball cock of approved quality,
quality, colour and make
colour and make
complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.
18.62.1
18.62.1 15 mm
15 mm nominal bore, 105
105 mm
mm long, weighing not
not less than
138 gms
138 gms each 182.10
18.62.2 20 mm nominal bore, 120
20 mm 120 mm
mm long, weighing not
not less than
198 gms
198 gms each 257.60
18.62.3 25 mm nominal bore, 152
25 mm 152 mm
mm long, weighing not
not less than
440
440 gms
gms each 523.80
18.62.4 40 mm nominal bore, 206
40 mm mm long, weighing not
206 mm not less than
690
690 gms
gms each 737.20
18.62.5 50 mm
50 mm nominal bore, 242 mm long, weighing not
242 mm not less than
1240 gms
gms each 1375.95
18.63 Providing and fixing
Providing and fixing PTMT angle stop
PTMT angle cock 15
stop cock 15 mm
mm nominal
nominal bore, weighing
bore, weighing
not less than 85
85 gms
gms each 156.90
18.64 Providing
Providing and fixing PTMT
and fixing swivelling shower,
PTMT swivelling shower, 15
15 mm mm nominal
nominal bore,
bore,
weighing not less than 40 40 gms
gms each 121.40
18.65 Providing and fixing
Providing and fixing PTMT
PTMT soap
soap Dish
Dish Holder
Holder having
having length of 138
length of 138 mm,
mm,
breadth
breadth 102
102 mm,
mm, height of 75
height of 75 mm with concealed
mm with concealed fitting
fitting arrangements,
arrangements,
weighing not less than 106106 gms. each 111.45
18.66 Providing and S&S C.I. Standard specials such as tees, bends,
and laying S&S
collars tapers
collars tapers and
and caps
caps etc, suitable for
etc, suitable for flanged
flanged jointing
jointing asas per
per IS
IS:: 1538
1538::
18.66.1
18.66.1 Up to 300
Up to 300 mm
mm dia
dia quintal 8628.60
18.66.2 Above 300 mm mm dia
dia quintal 10157.95
18.67 Providing and S&S C.I. Standard specials suitable for mechanical
and laying S&S
jointing as per IS
as per IS:: 13382
13382::
18.67.1
18.67.1 Up to 300
Up to 300 mm
mm dia
dia quintal 13764.35
18.67.2 Above 300 mm mm dia
dia quintal 14532.55

290
290 SUB HEAD:: 18.0 WATER SUPPLY
SUB SUPPLV
Code No Description Unit Rate
18.68 and laying D.I. specials of class K-12 suitable for push-on
Providing and
jointing as per IS
as per IS:: 9523
9523::
18.68.1
18.68.1 Up to 600
Up to 600 mm dia
mm dia quintal 20009.70
18.68.2 Above 600 mmmm dia
dia quintal 26696.10
18.68A Providing andand laying Class K-12 Ductile Iron double chamber restrained
joint (bolt
joint (bolt less) specials such
less) specials such as
as tees,
tees, bends, collars, tapers
bends, collars, tapers and
and caps etc.
caps etc.
conforming to IS:: 9523 including testing of joints all complete.
to IS
18.68A.1
18.68A.1 Up to 600
Up to 600 mm
mm nominal dia
nominal dia quintal 30394.95
18.68A.2 Above 600 mm mm nominal dia dia quintal 39073.05
18.69 Providing andand laying D.I. Specials ofof Class
ClassKK - 12
12 suitable for mechanical
jointing as per IS
as per IS:: 9523
9523::
18.69.1
18.69.1 Up to 600
Up to 600 mm dia
mm dia quintal 21290.10
18.69.2 Above 600 mm mm dia
dia quintal 28403.25
18.70 Providing
Providing push-on-joints
push-on-joints toto Centrifugally
Centrifugally (Spun)
(Spun) Cast
Cast Iron
Iron Pipes
Pipes or
or Ductile
Ductile
Iron Pipes including testing of joints andand the
the cost of rubber gasket:
gasket :
18.70.1
18.70.1 100 mm
100 mm dia pipes joint 119.45
18.70.2 150 mm
150 mm dia pipes joint 192.85
18.70.3 200 mm dia pipes
200 mm joint 280.85
18.70.4 250 mm dia pipes
250 mm joint 340.35
18.70.5 300 mm dia pipes
300 mm joint 435.45
18.70.6 350 mm dia pipes
350 mm joint 495.00
18.70.7 400 mm dia pipes
400 mm joint 696.80
18.70.8 450 mm dia pipes
450 mm joint 820.35
18.70.9 500 mm
500 mm dia pipes joint 871.45
18.70.10 600 mm dia pipes
600 mm joint 1207.90
18.70.11
18.70.11 700 mm
700 mm dia pipes joint 1572.70
18.70.12 750 mm
750 mm dia pipes joint 1693.65
18.70.13 800 mm dia pipes
800 mm joint 1844.40
18.70.14 900 mm dia pipes
900 mm joint 2314.65
18.70.15 mm diapipes
1000 mm dia pipes joint 2604.40
18.71
18.71 Providing and laying
Providing and laying Double
Double Flanged
Flanged (screwed
(screwed// welded)
welded) Centrifugally
Centrifugally
(Spun)
(Spun) Cast
Cast Iron,
Iron, Class
ClassBB (IS
(IS:: 1536)
1536)::
18.71.1
18.71.1 100 mm
100 mm dia C.I. Double Flanged Pipe metre 2089.35
18.71.2 150 mm
150 mm dia C.I. Double Flanged Pipe metre 3218.50
18.71.3 200 mm dia C.I. Double Flanged Pipe
200 mm metre 4995.85
18.71.4 250 mm dia C.I. Double Flanged Pipe
250 mm metre 6227.00
18.71.5 300 mm dia C.I. Double Flanged Pipe
300 mm metre 8094.30
18.71.6 350 mm dia C.I. Double Flanged Pipe
350 mm metre 10093.90
18.71.7 400 mm dia C.I. Double Flanged Pipe
400 mm metre 13136.65
18.71.8 450 mm dia C.I. Double Flanged Pipe
450 mm metre 16769.30
18.71.9 500 mm
500 mm dia C.I. Double Flanged Pipe metre 21619.65
18.71.10 600 mm dia C.I. Double Flanged Pipe
600 mm metre 27459.40
18.72 Providing and laying
Providing and laying S&S
S&S Centrifugally
Centrifugally Cast
Cast (Spun)
(Spun)// Ductile
Ductile Iron
Iron Pipes
Pipes
conforming to IS:: 8329:
to IS 8329 :
18.72.1
18.72.1 100 mm
100 mm dia Ductile Iron Class K-7 pipes metre 1257.80

SUB HEAD:: 18.0 WATER SUPPLY


SUB SUPPi.Y 291
Code No Description Unit Rate
18.72.2 150 mm
150 mm dia Ductile Iron Class K-7 pipes metre 1789.60
18.72.3 200 mm
200 mm dia Ductile Iron Class K-7 pipes metre 2328.15
18.72.4 250 mm
250 mm dia Ductile Iron Class K-7 pipes metre 2880.70
18.72.5 300 mm
300 mm dia Ductile Iron Class K-7 pipes metre 3518.25
18.72.6 350 mm
350 mm dia Ductile Iron Class K-7 pipes metre 4186.50
18.72.7 400 mm dia Ductile Iron Class K-7 pipes
400 mm metre 5084.55
18.72.8 450 mm dia Ductile Iron Class K-7 pipes
450 mm metre 6163.35
18.72.9 500 mm
500 mm dia Ductile Iron Class K-7 pipes metre 6787.40
18.72.10 600 mm
600 mm dia Ductile Iron Class K-7 pipes metre 8965.95
18.72.11
18.72.11 700 mm
700 mm dia Ductile Iron Class K-7 pipes metre 11566.35
18.72.12 800 mm
800 mm dia Ductile Iron Class K-7 pipes metre 14609.05
18.72.13 900 mm
900 mm dia Ductile Iron Class K-7 pipes metre 18734.20
18.72.14 mm dia
1000 mm diaDuctile
Ductile Iron Class K-7 pipes metre 19895.80
18.72.15 100 mm
100 mm dia Ductile Iron Class K-9 pipes metre 1344.60
18.72.16 150 mm
150 mm dia Ductile Iron Class K-9 pipes metre 1837.75
18.72.17 200 mm
200 mm dia Ductile Iron Class K-9 pipes metre 2478.10
18.72.18 250 mm
250 mm dia Ductile Iron Class K-9 pipes metre 3516.80
18.72.19 300 mm
300 mm dia Ductile Iron Class K-9 pipes metre 4344.40
18.72.20 350 mm
350 mm dia Ductile Iron Class K-9 pipes metre 5409.85
18.72.21
18.72.21 400 mm dia Ductile Iron Class K-9 pipes
400 mm metre 6844.30
18.72.22 450 mm dia Ductile Iron Class K-9 pipes
450 mm metre 7976.85
18.72.23 500 mm
500 mm dia Ductile Iron Class K-9 pipes metre 9679.85
18.72.24 600 mm
600 mm dia Ductile Iron Class K-9 pipes metre 12986.95
18.72.25 700 mm
700 mm dia Ductile Iron Class K-9 pipes metre 17431.60
18.72.26 750 mm
750 mm dia Ductile Iron Class K-9 pipes metre 18567.85
18.72.27 800 mm
800 mm dia Ductile Iron Class K-9 pipes metre 18891.20
18.72.28 900 mm
900 mm dia Ductile Iron Class K-9 pipes metre 23163.00
18.72.29 mm dia
1000 mm diaDuctile
Ductile Iron Class K-9 pipes metre 25133.00
18.72A Providing, laying, jointing and
Providing, and testing S&S
S&S Centrifugally Cast Ductile Iron
double chamber Class K-9 pressure pipes conforming to IS:: 8329:2000
to IS
with restrained
with joints (bolt
restrained joints (bolt less),
less), all
all complete.
complete.
18.72A.1
18.72A.1 100 mm
100 mm nominal dia
dia pipe metre 1870.75
18.72A.2 150 mm
150 mm nominal dia
dia pipe metre 2590.90
18.72A.3 200 mm
200 mm nominal dia
dia pipe metre 3260.55
18.72A.4 250 mm
250 mm nominal dia
dia pipe metre 4357.60
18.72A.5 300 mm
300 mm nominal dia
dia pipe metre 5452.95
18.72A.6 350 mm
350 mm nominal dia
dia pipe metre 6636.80
18.72A.7 400 mm nominal dia
400 mm dia pipe metre 8279.45
18.72A.8 450 mm nominal dia
450 mm dia pipe metre 9861.20
18.72A.9 500 mm
500 mm nominal dia
dia pipe metre 11628.30
18.72A.10 600 mm
600 mm nominal dia
dia pipe metre 15202.60
18.72A.11
18.72A.11 700 mm
700 mm nominal dia
dia pipe metre 19217.15
18.72A.12 750 mm
750 mm nominal dia
dia pipe metre 21627.85

292
292 SUB HEAD:: 18.0 WATER SUPPLY
SUB SUPPLV
Code No Description Unit Rate
18.72A.13 800 mm
800 mm nominal dia
dia pipe metre 23932.65
18.72A.14 900 mm
900 mm nominal dia
dia pipe metre 29836.95
18.72A.15 mm nominal dia
1000 mm dia pipe metre 36164.10
18.73 Providing
Providing and
and laying
laying Double
Double Flanged
Flanged (Screwed/ Welded) Centrifugally
(Screwed/ Welded) Centrifugally
(Spun)
(Spun) Ductile
Ductile Iron
Iron Pipes
Pipes of
of Class
ClassKK -9
- 9 conforming
conforming to
to IS
IS:: 8329
8329::
18.73.1
18.73.1 100 mm
100 mm dia Ductile Iron Double Flanged metre 1821.55
18.73.2 150 mm
150 mm dia Ductile Iron Double Flanged metre 2607.50
18.73.3 200 mm
200 mm dia Ductile Iron Double Flanged metre 3360.80
18.73.4 250 mm
250 mm dia Ductile Iron Double Flanged metre 4696.15
18.73.5 300 mm
300 mm dia Ductile Iron Double Flanged metre 5895.70
18.73.6 350 mm
350 mm dia Ductile Iron Double Flanged metre 7550.45
18.73.7 400 mm dia Ductile Iron Double Flanged
400 mm metre 9744.40
18.73.8 450 mm dia Ductile Iron Double Flanged
450 mm metre 10136.10
18.73.9 500 mm
500 mm dia Ductile Iron Double Flanged metre 15472.95
18.73.10 600 mm
600 mm dia Ductile Iron Double Flanged metre 19925.30
18.73.11
18.73.11 700 mm
700 mm dia Ductile Iron Double Flanged metre 22830.80
18.74 Providing and fixing
Providing and fixing unplasticised
unplasticised P.V.C. connection pipe
P.V.C. connection with PTMT
pipe with PTMT Nuts,
Nuts,
collar and
and bush ofapproved
of approved quality and
and colour.
18.74.1
18.74.1 15 mm
15 mm nominal bore with 30
30 cm
cm length each 96.35
18.74.2 15 mm
15 mm nominal bore with 45
45 cm
cm length each 121.90
18.75 Providing and fixing
Providing and fixing PTMT extension nipple
PTMT extension for water
nipple for water tank
tank pipe, fittings of
pipe, fittings of
approved quality and
and colour.
18.75.1
18.75.1 15 mm
15 mm nominal bore, weighing not
not less than 32
32 gms
gms each 53.60
18.75.2 20 mm nominal bore, weighing not
20 mm not less than 40
40 gms
gms each 93.45
18.75.3 25 mm nominal bore, weighing not
25 mm not less than 62
62 gms
gms each 113.35
18.76 up to 30x30 cm
Cutting holes up cm in walls including making good thesame:
the same:
18.76.1
18.76.1 With common
With common burnt
burnt clay
clay F.P.S.
F.P.S. (non
(non modular)
modular) bricks
bricks each 416.80
18.77 Cutting
Cutting holes
holes up to 15x15
up to 15x15 cmcm inin R.C.C. floors and
R.C.C. floors and roofs for passing
roofs for passing
drain pipe etc. and
and repairing the
the hole after insertion of drain pipe etc.
with cement concrete
concrete11:2:4
:2:4 (1
(1 cement:2
cement : 2 coarse sandsand:4
: 4 graded stone
aggregate 20
aggregate 20 mm
mm nominal
nominal size),
size), including finishing complete
including finishing complete soso as
as to
to
make it leak proof. each 452.00
18.78 Making chases up to to 7.5x7.5 cm
cm in walls including making good and
finishing with
finishing with matching surface after
matching surface after housing
housing G.I.
G.I. pipe etc.
pipe etc. metre 202.90
18.79 up to 20x20 cm
Making hole up cm and embedding pipes upup to 150
150 mm
mm diameter
in
in masonry and filling
masonry and filling with
with cement concrete 1:3:6
cement concrete 1:3:6 (1
(1 cement
cement:3 : 3 coarse
coarse
sand: 6 graded
sand:6 graded stone
stone aggregate
aggregate 20
20 mm
mm nominal
nominal size)
size) including disposal
including disposal
of malba. metre 209.20
18.80 Disinfecting
Disinfecting C.I. water mains
C.I. water mains by flushing with
by flushing with water
water containing
containing bleaching
bleaching
powder@@ 0.5
powder 0.5 gms
gms per
per litre of
of water and
and cleaning the same with fresh
water, operation to be
be repeated three times including getting thethe sample
ofwater
of water from the disinfected main tested in the laboratory.
the municipal laboratory.
18.80.1
18.80.1 80 mm diameter C.I. pipe
80 mm 100 metre 1844.00
18.80.2 100 mm
100 mm diameter C.I. pipe 100 metre 2415.15
18.80.3 125 mm
125 mm diameter C.I. pipe 100 metre 3006.40
18.80.4 150 mm
150 mm diameter C.I. pipe 100 metre 3593.85

SUB HEAD:
SUB SUPPL•Y
HEAD : 18.0 WATER SUPPLY 293
Code No Description Unit Rate
18.80.5 200 mm
200 mm diameter C.I. pipe 100 metre 4771.60
18.80.6 250 mm
250 mm diameter C.I. pipe 100 metre 5977.65
18.80.7 300 mm
300 mm diameter C.I. pipe 100 metre 6618.15
18.80.8 350 mm
350 mm diameter C.I. pipe 100 metre 7272.35
18.80.9 400 mm diameter C.I. pipe
400 mm 100 metre 7950.85
18.80.10 450 mm diameter C.I. pipe
450 mm 100 metre 8635.75
18.80.11
18.80.11 500 mm
500 mm diameter C.I. pipe 100 metre 9351.25
18.80.12 600 mm
600 mm diameter C.I. pipe 100 metre 10787.45
18.81
18.81 Extra for every
Extra for every operation of disinfecting
operation of disinfecting the
the C.I.
C.I. main
main by flushing with
by flushing with
water containing bleaching powder
powder@@ 0.5 0.5 gms per litre of
gms per of water and
and
cleaning the same with fresh water, including getting the
the samples of ofwater
water
tested in the laboratory::
the municipal laboratory
18.81.1
18.81.1 80 mm diameter C.I. pipe
80 mm 100 metre 674.95
18.81.2 100 mm
100 mm diameter C.I. pipe 100 metre 824.95
18.81.3 125 mm
125 mm diameter C.I. pipe 100 metre 1003.95
18.81.4 150 mm
150 mm diameter C.I. pipe 100 metre 1164.25
18.81.5 200 mm diameter C.I. pipe
200 mm 100 metre
100 1753.10
18.81.6 250 mm diameter C.I. pipe
250 mm 100 metre 2012.75
18.81.7 300 mm diameter C.I. pipe
300 mm 100 metre 2255.15
18.81.8 350 mm diameter C.I. pipe
350 mm 100 metre 2632.00
18.81.9 400 mm diameter C.I. pipe
400 mm 100 metre 3011.20
18.81.10 450 mm diameter C.I. pipe
450 mm 100 metre 3398.15
18.81.11
18.81.11 500 mm diameter C.I. pipe
500 mm 100 metre 3787.10
18.81.12 600 mm diameter C.I. pipe
600 mm 100 metre 4573.95
18.82 Dismantling old C.I.
Dismantling old C.I. pipes
pipes including excavation and
including excavation and refilling trenches after
refilling trenches after
taking out the pipes, breaking lead caulked joints, melting of lead and and
making into blocks, including stacking of pipes at site lead up
up to 50
50 metre:
18.82.1
18.82.1 80 mm diameter C.I. pipe
80 mm metre 315.55
18.82.2 100 mm
100 mm diameter C.I. pipe metre 332.50
18.82.3 125 mm
125 mm diameter C.I. pipe metre 348.75
18.82.4 150 mm
150 mm diameter C.I. pipe metre 365.45
18.82.5 200 mm diameter C.I. pipe
200 mm metre 411.50
18.82.6 250 mm diameter C.I. pipe
250 mm metre 456.60
18.82.7 300 mm diameter C.I. pipe
300 mm metre 497.80
18.82.8 350 mm diameter C.I. pipe
350 mm metre 538.00
18.82.9 400
400 mmmm diameter C.I. pipe metre 575.80
18.82.10 450
450 mmmm diameter C.I. pipe metre 614.30
18.82.11
18.82.11 500 mm
500 mm diameter C.I. pipe metre 649.45
18.82.12 600
600 mmmm diameter C.I. pipe metre 713.95
18.83 Labour forcutting
for cutting C.I. pipe with steel saw.
18.83.1
18.83.1 80 mm diameter C.I. pipe
80 mm each cut
cut 145.25
18.83.2 100 mm
100 mm diameter C.I. pipe each cut
cut 194.70
18.83.3 125 mm
125 mm diameter C.I. pipe each cut
cut 269.80
18.83.4 150 mm
150 mm diameter C.I. pipe each cut
cut 365.70

294
294 SUB HEAD:: 18.0 WATER SUPPLY
SUB SUPPLV
Code No Description Unit Rate
18.83.5 200 mm
200 mm diameter C.I. pipe each cut
cut 487.75
18.83.6 250 mm
250 mm diameter C.I. pipe each cut
cut 606.85
18.83.7 300 mm
300 mm diameter C.I. pipe each cut
cut 728.85
18.83.8 350 mm
350 mm diameter C.I. pipe each cut
cut 847.95
18.83.9 400 mm diameter C.I. pipe
400 mm each cut
cut 969.55
18.83.10 450 mm diameter C.I. pipe
450 mm each cut
cut 1089.10
18.83.11
18.83.11 500 mm
500 mm diameter C.I. pipe each cut
cut 1210.70
18.83.12 600 mm
600 mm diameter C.I. pipe each cut
cut 1445.95
18.84 Providing
Providing && fixing
fixing chrome
chrome plated
plated brass
brass battery
battery based
based infrared sensor
infrared sensor
operated
operated pillar
pillar cock,
cock, having foam flow
having foam flow technology.
technology.
18.84.1
18.84.1 15 mm
15 mm nominal bore each 8803.70
18.85 Providing and fixing
Providing and fixing Stainless
Stainless Steel
Steel pipe and fitting
pipe and fitting of
of grade
grade AISI
AISI 304
304
as
as per
per JIS standard 3448
JIS standard 3448 complete
complete with
with press
press typetype fitting
fitting (fitting
(fitting shall
shall
be
be paid for separately)
paid for separately) including fixing of
including fixing of the
the pipe with clamps
pipe with clamps at at 1.00
1.00 m
m
spacing including cutting and and making good thewalls
the walls including testing of
joints complete as per per direction of Engineer-in-charge. (The pipe length
inserted
inserted in the fitting
in the fitting shall
shall not
not be
be measured for payment)
measured forpayment)
Internal work - Exposed on wall
18.85.1
18.85.1 mm outer dia pipe
15.88 mm metre 420.25
18.85.2 22.22 mm
mm outer dia Pipe metre 599.50
18.85.3 28.58 mm mm outer dia Pipe metre 704.55
18.85.4 34.00 mm mm outer dia Pipe metre 913.65
18.85.5 42.70 mm mm outer dia Pipe metre 943.90
18.85.6 48.60 mm mm outer dia Pipe metre 1202.35
18.85A Providing
Providing andand fixing
fixing Stainless
Stainless Steel
Steel pipe and fitting
pipe and fitting of
of grade
grade 316L
316L asas per
per
IS:: 6911:2017 and
IS and conforming to to EN-10312 standards complete with press
type fitting
type fitting (fitting shall be
(fitting shall be paid for separately)
paid for separately) including fixing of
including fixing of the
the pipe
pipe
with clamps at1.00
at 1.00 m m spacing including cutting and and making good thewalls
the walls
including testing of joints complete as per direction of Engineer-in-charge.
(The
(The pipe
pipe length
length inserted
inserted in the fitting
in the fitting shall
shall not
not be
be measured for payment)
measured forpayment)
Internal work - Exposed on wall
18.85A.1
18.85A.1 15 mm
15 mm outer dia pipe metre 704.05
18.85A.2 22
22 mmmm outer dia Pipe metre 1025.25
18.85A.3 28
28 mmmm outer dia Pipe metre 1272.15
18.85A.4 35 mm outer dia Pipe
35 mm metre 1765.10
18.85A.5 42 mm outer dia Pipe
42 mm metre 2124.00
18.85A.6 54 mm
54 mm outer dia Pipe metre 2699.10
18.86 Providing and fixing
Providing and fixing Stainless
Stainless Steel
Steel pipe
pipe and fitting of
and fitting of grade
grade AISI
AISI 304
304 as
as
per JIS standard
per JIS 3448 complete
standard 3448 complete withwith press type fitting
press type fitting (fitting
(fitting shall
shall be
be paid
paid
for separately)
for separately) including fixing of
including fixing the pipe
of the with clamps
pipe with clamps at at 1.00m
1.00m spacing
spacing
and also including cutting of chases and making good thewalls
and the walls including
testing of joints complete as per direction of Engineer -in-charge. -in-charge. (The
pipe
pipe length
length inserted
inserted in the fitting
in the fitting shall
shall not
not be
be measured for payment)
measured forpayment)
Internal work - Concealed Pipe
18.86.1
18.86.1 mm outer dia Pipe.
15.88 mm metre 622.25
18.86.2 22.22 mm
mm Outer dia
dia pipe metre 801.50

SUB HEAD:: 18.0 WATER SUPPLY


SUB SUPPi.Y 295
Code No Description Unit Rate
18.86A Providing
Providing and fixing Stainless
and fixing Stainless Steel
Steel pipe and fitting
pipe and fitting of
of grade
grade 316L
316L as as per
per
IS:: 6911:2017 and
IS and conforming to to EN-10312 standards complete with
press type fitting
press type fitting (fitting shall be
(fitting shall be paid for separately) including
paid forseparately) fixing of
including fixing of the
the
pipe with clamps at at 1.00m spacing and and also including cutting of chases
and making good the the walls including testing of joints complete as per per
direction of Engineer
direction of Engineer -in-charge.
-in-charge. (The
(The pipe
pipe length
length inserted
inserted in the fitting
in the fitting
shall
shall not
not be
be measured for payment)
measured forpayment)
Internal work - Concealed Pipe
18.86A.1
18.86A.1 mm outer dia Pipe.
15 mm metre 906.10
18.86A.2 22 mm Outer dia
22 mm dia pipes metre 1227.25
18.87 Providing
Providing and fixing required
and fixing required Stainless
Stainless Steel
Steel Fitting of press
Fitting of fit design
press fit design
of
of grade AISI 304
grade AISI conforming to
304 conforming to JWWA
JWWA G116 standard with
G116 standard with V-profile
V-profile or
or
M-profile
M-profile and with O-ring
and with sealing gasket
O-ring sealing of EPDM
gasket of EPDM material
material of
of required dia
required dia
as per direction of Engineer-in-charge.
as
Coupling/Socket
18.87.1
18.87.1 For 15.88 mm
For mm outer dia pipe each 93.90
18.87.2 For 22.22 mm
mm outer dia pipe each 113.80
18.87.3 For 28.58 mm
mm outer dia pipe each 156.50
18.87.4 mm outer dia pipe
For 34.00 mm each 213.40
18.87.5 For 42.70 mm
mm outer dia pipe each 256.10
18.87.6 For 48.60 mm
mm outer dia pipe each 291.65
18.87A Providing and fixing
Providing and fixing required
required Stainless
Stainless Steel
Steel Fitting of press
Fitting of fit design
press fit design of
of
grade 316L as perperIS
IS:: 6911:2017 and
and conforming to to EN-10312 standards
with V-profile
with V-profile and
and with
with O-ring
O-ring sealing
sealing gasket
gasket of
of EPDM
EPDM material
material of
of required
required
dia as
as per direction of Engineer-in-charge.
Coupling/Socket
18.87A.1
18.87A.1 15 mm
For 15 mm outer dia pipe each 341.45
18.87A.2 For 22 mm outer dia pipe
22 mm each 426.80
18.87A.3 28 mm
For 28 mm outer dia pipe each 497.90
18.87A.4 35 mm
For 35 mm outer dia pipe each 625.95
18.87A.5 For 42 mm outer dia pipe
42 mm each 846.45
18.87A.6 For 54
54 mm
mm outer dia pipe each 1017.20
18.88 Providing
Providing and fixing required
and fixing required Stainless
Stainless Steel
Steel Fitting
Fitting of
of press fit design
press fit design
of grade
of grade AISI
AISI 304
304 conforming
conforming toto JWWA
JWWA G116 standard with
G116 standard with V-profile
V-profile or
or
M-profile
M-profile and with O-ring
and with O-ring sealing
sealing gasket of EPDM
gasket of EPDM material
material ofof providing
providing
and fixing
and fixing required
required Stainless
Stainless Steel
Steel Fitting of press
Fitting of fit design
press fit design ofof grade
grade
AISI 304
AISI 304 conforming
conforming to to JWWA
JWWA G116
G116 standard with V-profile
standard with V-profile or
or M-profile
M-profile
and
and with O-ring sealing gasket of of EPDM material of required dia as as per
dirction of Engineer-in-charge.
Reducer
18.88.1
18.88.1 For 22.22 mm
For mm xx 15.88 mm
mm outer dia pipe each 139.40
18.88.2 mm xx 15.88 mm
For 28.58 mm mm outer dia pipe each 186.35
18.88.3 mm xx 22.22 mm
For 28.58 mm mm outer dia pipe each 189.20
18.88.4 mm xx 15.88 mm
For 34.00 mm mm outer dia pipe each 313.00
18.88.5 mm xx 22.22 mm
For 34.00 mm mm outer dia pipe each 327.20
18.88.6 mm xx 28.58 mm
For 34.00 mm mm outer dia pipe each 327.20
18.88.7 For 42.70 mm
mm xx 15.88 mm
mm outer dia pipe each 517.85

296 SUB HEAD:: 18.0 WATER SUPPLY


SUB SUPPLV
Code No Description Unit Rate
18.88.8 For 42.70 mm
mm xx 22.22 mm
mm outer dia pipe each 529.25
18.88.9 For 42.70 mm
mm xx 28.58 mm
mm outer dia pipe each 606.05
18.88.10 For 42.70 mm
mm xx 34.00 mm
mm outer dia pipe each 643.05
18.88.11
18.88.11 For 48.60 mm
For mm xx 15.88 mm
mm outer dia pipe each 643.05
18.88.12 For 48.60 mm
mm xx 22.22 mm
mm outer dia pipe each 643.05
18.88.13 For 48.60 mm
mm xx 28.58 mm
mm outer dia pipe each 643.05
18.88.14 For 48.60 mm
mm xx 34.00 mm
mm outer dia pipe each 664.35
18.88.15 For 48.60 mm
mm xx 42.70 mm
mm outer dia pipe each 667.20
18.88A Providing and fixing
Providing and fixing required
required Stainless
Stainless Steel
Steel Fitting
Fitting of
of press fit design
press fit design of
of
grade 316L as perperIS
IS:: 6911:2017 and
and conforming to to EN-10312 standards
with V-profile
with V-profile and with O-ring
and with sealing gasket
O-ring sealing gasket of
of EPDM
EPDM material of required
material of required
as per dirction of Engineer-in-charge.
dia as
Reducer
18.88A.1
18.88A.1 For 22 mm xx 15
22 mm 15 mm
mm outer dia pipe each 405.45
18.88A.2 For 28 mm xx 15 mm
28 mm mm outer dia pipe each 490.80
18.88A.3 For 28 mm xx 22
28 mm mm outer dia pipe
22 mm each 597.50
18.88A.4 For 35
35 mm
mm xx 22 mm outer dia pipe
22 mm each 604.60
18.88A.5 35 mm
For 35 mm xx 28 mm outer dia pipe
28 mm each 746.85
18.88A.6 For 42 mm xx 22
42 mm mm outer dia pipe
22 mm each 960.30
18.88A.7 For 42 mm xx 28
42 mm mm outer dia pipe
28 mm each 1095.45
18.88A.8 For 42 mm xx 35
42 mm 35 mm
mm outer dia pipe each 1145.25
18.88A.9 54 mm
For 54 mm xx 28 mm outer dia pipe
28 mm each 1330.15
18.88A.10 54 mm
For 54 mm xx 35
35 mm
mm outer dia pipe each 1572.00
18.88A.11
18.88A.11 54 mm
For 54 mm xx 42 mm outer dia pipe
42 mm each 1636.05
18.89 Providing
Providing and fixing required
and fixing required Stainless
Stainless Steel
Steel Fitting of press
Fitting of fit design
press fit design
of
of grade AISI 304
grade AISI conforming to
304 conforming to JWWA
JWWA G116 standard with
G116 standard with V-profile
V-profile or
or
M-profile
M-profile and with O-ring
and with sealing gasket
O-ring sealing of EPDM
gasket of EPDM material
material of
of required dia
required dia
as per direction of Engineer-in-charge.
as
Slip Coupling/ Socket
18.89.1
18.89.1 For 15.88 mm
For mm outer dia pipe each 92.45
18.89.2 For 22.22 mm
mm outer dia pipe each 113.80
18.89.3 For 28.58 mm
mm outer dia pipe each 156.50
18.89.4 For 34.00 mm
mm outer dia pipe each 220.50
18.89.5 For 42.70 mm
mm outer dia pipe each 256.10
18.89.6 For 48.60 mm
mm outer dia pipe each 277.40
18.89A Providing and fixing
Providing and fixing required
required Stainless
Stainless Steel
Steel Fitting of press
Fitting of fit design
press fit design of
of
grade 316L as perperIS
IS:: 6911:2017 and
and conforming to to EN-10312 standards
with V-profile
with V-profile and
and with
with O-ring
O-ring sealing
sealing gasket
gasket of
of EPDM
EPDM material
material of
of required
required
dia as
as per direction of Engineer-in-charge.
Sleeve/Slip Coupling/ Socket
18.89A.1
18.89A.1 15 mm
For 15 mm outer dia pipe each 597.50
18.89A.2 For 22 mm outer dia pipe
22 mm each 711.30
18.89A.3 28 mm
For 28 mm outer dia pipe each 825.15
18.89A.4 35 mm
For 35 mm outer dia pipe each 917.60
18.89A.5 For 42 mm outer dia pipe
42 mm each 1066.95

SUB HEAD:: 18.0 WATER SUPPLY


SUB SUPPi.Y 297
Code No Description Unit Rate
18.89A.6 54 mm
For 54 mm outer dia pipe each 1515.10
18.90 Providing and fixing
Providing and fixing required
required Stainless
Stainless Steel
Steel Fitting of press
Fitting of fit design
press fit design
of
of grade AISI 304
grade AISI 304 conforming to JWWA
conforming to JWWA G116 standard with
G116 standard with V-profile
V-profile or
or
M-profile
M-profile and with O-ring
and with sealing gasket
O-ring sealing of EPDM
gasket of EPDM material
material of
of required dia
required dia
as per direction of Engineer-in-charge.
as
90°
Elbow 90°
18.90.1
18.90.1 For 15.88 mm
For mm outer dia pipe each 99.60
18.90.2 For 22.22 mm
mm outer dia pipe each 113.80
18.90.3 For 28.58 mm
mm outer dia pipe each 163.60
18.90.4 mm outer dia pipe
For 34.00 mm each 204.85
18.90.5 For 42.70 mm
mm outer dia pipe each 221.95
18.90.6 For 48.60 mm
mm outer dia pipe each 273.15
18.90A Providing and fixing
Providing and fixing required
required Stainless
Stainless Steel
Steel Fitting
Fitting of
of press fit design
press fit design of
of
grade 316L as perperIS
IS:: 6911:2017 and
and conforming to to EN-10312 standards
with V-profile
with V-profile and
and with
with O-ring sealing gasket
O-ring sealing gasket of
of EPDM
EPDM material of required
material of required
as per direction
dia as direction of Engineer-in-charge.
90°
Elbow 90°
18.90A.1
18.90A.1 15 mm
For 15 mm outer dia pipe each 483.70
18.90A.2 For 22 mm outer dia pipe
22 mm each 682.85
18.90A.3 For 28 mm outer dia pipe
28 mm each 910.50
18.90A.4 35 mm
For 35 mm outer dia pipe each 1493.75
18.90A.5 For 42 mm outer dia pipe
42 mm each 2418.50
18.90A.6 54 mm
For 54 mm outer dia pipe each 3200.95
18.91
18.91 Providing
Providing and fixing required
and fixing required Stainless
Stainless Steel
Steel Fitting of press
Fitting of fit design
press fit design
of grade
of grade AISI
AISI 304
304 conforming
conforming to
to JWWA
JWWA G116 standard with
G116 standard with V-profile
V-profile or
or
M-profile and with
M-profile and with O-ring sealing gasket
O-ring sealing gasket of
of EPDM
EPDM material of required
material of dia
required dia
as
as per direction of Engineer-in-charge.
Reducing Elbow 90° 90°
18.91.1
18.91.1 For22.22 mmmm xx 15.88 mm
mm outer dia pipe each 223.35
18.91.2 For 28.58 mmmm xx 15.88 mm
mm outer dia pipe each 304.45
18.91.3 For 28.58 mmmm xx 22.22 mm
mm outer dia pipe each 318.65
18.91.4 For 34.00 mmmm xx 22.22 mm
mm outer dia pipe each 426.80
18.91.5 mm xx 28.58 mm
For 34.00 mm mm outer dia pipe each 512.15
18.91.6 For 42.70 mm
mm xx 34.00 mm
mm outer dia pipe each 554.80
18.92 Providing
Providing and fixing required
and fixing required Stainless
Stainless Steel
Steel Fitting
Fitting of
of press fit design
press fit design
of grade
of grade AISI
AISI 304
304 conforming
conforming to
to JWWA
JWWA G116 standard with
G116 standard with V-profile
V-profile or
or
M-profile and with
M-profile and with O-ring sealing gasket
O-ring sealing gasket of
of EPDM
EPDM material of required
material of dia
required dia
as
as per direction of Engineer-in-charge.
Equal Tee
Tee
18.92.1
18.92.1 For 15.88 mm
For mm outer dia pipe each 197.75
18.92.2 For 22.22 mm
mm outer dia pipe each 300.20
18.92.3 mm outer dia pipe
For 28.58 mm each 466.60
18.92.4 mm outer dia pipe
For 34.00 mm each 688.55
18.92.5 For 42.70 mm
mm outer dia pipe each 1088.30
18.92.6 For 48.60 mm
mm outer dia pipe each 1429.75

298
298 SUB HEAD:: 18.0 WATER SUPPLY
SUB SUPPLV
Code No Description Unit Rate
18.92A Providing and fixing
Providing and fixing required
required Stainless
Stainless Steel
Steel Fitting
Fitting of
of press fit design
press fit design of
of
grade 316L as perperIS
IS:: 6911:2017 and
and conforming to to EN-10312 standards
with V-profile
with V-profile and with O-ring
and with sealing gasket
O-ring sealing of EPDM
gasket of EPDM material of required
material of required
as per direction of Engineer-in-charge.
dia as
Equal Tee
Tee
18.92A.1
18.92A.1 15 mm
For 15 mm outer dia pipe each 796.70
18.92A.2 For 22 mm outer dia pipe
22 mm each 931.85
18.92A.3 For 28 mm outer dia pipe
28 mm each 1145.25
18.92A.4 35 mm
For 35 mm outer dia pipe each 1422.65
18.92A.5 For 42 mm outer dia pipe
42 mm each 1991.70
18.92A.6 54 mm
For 54 mm outer dia pipe each 2390.05
18.93 Providing
Providing and fixing required
and fixing required Stainless
Stainless Steel
Steel Fitting of press
Fitting of fit design
press fit design
of grade AISI
of grade AISI 304 conforming to
304 conforming to JWWA
JWWA G116 standard with
G116 standard with V-profile
V-profile or
or
M-profile
M-profile and with O-ring
and with O-ring sealing gasket of
sealing gasket of EPDM
EPDM material of required
material of dia
required dia
as per direction of Engineer-in-charge.
as
Reducing Tee
18.93.1
18.93.1 For 22.22 mm
For mm xx 15.88 mm
mm outer dia pipe each 268.85
18.93.2 For 28.58 mm
mm xx 15.88 mm
mm outer dia pipe each 357.10
18.93.3 For 28.58 mm
mm xx 22.22 mm
mm outer dia pipe each 362.75
18.93.4 mm xx 15.88 mm
For 34.00 mm mm outer dia pipe each 633.10
18.93.5 mm xx 22.22 mm
For 34.00 mm mm outer dia pipe each 654.40
18.93.6 mm xx 28.58 mm
For 34.00 mm mm outer dia pipe each 675.75
18.93.7 For 42.70 mm
mm xx 15.88 mm
mm outer dia pipe each 1045.65
18.93.8 For 42.70 mm
mm xx 22.22 mm
mm outer dia pipe each 1066.95
18.93.9 For 42.70 mm
mm xx 28.58 mm
mm outer dia pipe each 1095.45
18.93.10 For 42.70 mm
mm xx 34.00 mm
mm outer dia pipe each 1123.90
18.93.11
18.93.11 For 48.60 mm
For mm xx 15.88 mm
mm outer dia pipe each 1280.35
18.93.12 For 48.60 mm
mm xx 22.22 mm
mm outer dia pipe each 1296.00
18.93.13 For 48.60 mm
mm xx 28.58 mm
mm outer dia pipe each 1320.20
18.93.14 For 48.60 mm
mm xx 34.00 mm
mm outer dia pipe each 1372.85
18.93.15 For 48.60 mm
mm xx 42.70 mm
mm outer dia pipe each 1401.30
18.93A Providing and fixing
Providing and fixing required
required Stainless
Stainless Steel
Steel Fitting of press
Fitting of fit design
press fit design of
of
grade 316L as perperIS
IS:: 6911:2017 and
and conforming to to EN-10312 standards
with V-profile
with V-profile and
and with
with O-ring
O-ring sealing
sealing gasket
gasket of
of EPDM
EPDM material
material of
of required
required
dia as
as per direction of Engineer-in-charge.
Reducing Tee
18.93A.1
18.93A.1 22 mm
For 22 mm xx 1515 mm
mm outer dia pipe each 910.50
18.93A.2 For 28 mm xx 15 mm
28 mm mm outer dia pipe each 1131.00
18.93A.3 For 28 mm xx 22
28 mm mm outer dia pipe
22 mm each 1138.10
18.93A.4 35 mm
For 35 mm xx 15 mm
mm outer dia pipe each 1429.75
18.93A.5 35 mm
For 35 mm xx 22 mm outer dia pipe
22 mm each 1436.85
18.93A.6 35 mm
For 35 mm xx 28 mm outer dia pipe
28 mm each 1451.10
18.93A.7 For 42 mm xx 22
42 mm mm outer dia pipe
22 mm each 2013.05
18.93A.8 For 42 mm xx 28
42 mm mm outer dia pipe
28 mm each 2034.35
18.93A.9 For 42 mm xx 35
42 mm 35 mm
mm outer dia pipe each 2048.60

SUB HEAD:: 18.0 WATER SUPPLY


SUB SUPPi.Y 299
Code No Description Unit Rate
18.93A.10 54 mm
For 54 mm xx 22 mm outer dia pipe
22 mm each 2390.05
18.93A.11
18.93A.11 54 mm
For 54 mm xx 28 mm outer dia pipe
28 mm each 2446.95
18.93A.12 54 mm
For 54 mm xx 35
35 mm
mm outer dia pipe each 2468.25
18.93A.13 54 mm
For 54 mm xx 42 mm outer dia pipe
42 mm each 2496.75
18.94 Providing
Providing and fixing required
and fixing required Stainless
Stainless Steel
Steel Fitting of press
Fitting of fit design
press fit design
of
of grade AISI 304
grade AISI 304 conforming to JWWA
conforming to JWWA G116 standard with
G116 standard with V-profile
V-profile or
or
M-profile
M-profile and with O-ring
and with sealing gasket
O-ring sealing of EPDM
gasket of EPDM material
material of
of required dia
required dia
as per direction of Engineer-in-charge.
as
Male Thread Tee
18.94.1
18.94.1 For 15.88 mm
For mm outer diaxx 15
15 mm
mm nominal dia
dia threaded each 291.65
18.94.2 For 22.22 mm
mm outer diaxx 15
15 mm
mm nominal dia
dia threaded each 334.30
18.94.3 For 22.22 mm
mm outer diaxx 20 mm nominal dia
20 mm dia threaded each 355.65
18.94.4 For 28.58 mm
mm outer diaxx 15
15 mm
mm nominal dia
dia threaded each 448.15
18.94.5 For 28.58 mm
mm outer diaxx 20 mm nominal dia
20 mm dia threaded each 462.35
18.94.6 For 28.58 mm
mm outer diaxx 25 mm nominal dia
25 mm dia threaded each 476.60
18.94.7 mm outer diaxx 15
For 34.00 mm 15 mm
mm nominal dia
dia threaded each 661.50
18.94.8 For 34.00 mm
mm outer diaxx 20 mm nominal dia
20 mm dia threaded each 675.75
18.94.9 mm outer diaxx 25
For 34.00 mm mm nominal dia
25 mm dia threaded each 704.20
18.94.10 mm outer diax
For 34.00 mm dia x 32 mm nominal dia
32 mm dia threaded each 732.65
18.94.11
18.94.11 For 42.70 mm
For mm outer diaxx 15
15 mm
mm nominal dia
dia threaded each 1010.05
18.94.12 For 42.70 mm
mm outer diaxx 20 mm nominal dia
20 mm dia threaded each 1031.40
18.94.13 For 42.70 mm
mm outer diaxx 25 mm nominal dia
25 mm dia threaded each 1088.30
18.94.14 For 42.70 mm
mm outer diaxx 32
32 mm
mm nominal dia
dia threaded each 1131.00
18.94.15 For 42.70 mm
mm outer diaxx 40 mm nominal dia
40 mm dia threaded each 1173.65
18.94.16 For 48.60 mm
mm outer diaxx 15
15 mm
mm nominal dia
dia threaded each 1415.55
18.94.17 For 48.60 mm
mm outer diaxx 20 mm nominal dia
20 mm dia threaded each 1442.55
18.94.18 For 48.60 mm
mm outer diaxx 25 mm nominal dia
25 mm dia threaded each 1458.20
18.94.19 For 48.60 mm
mm outer diaxx 32
32 mm
mm nominal dia
dia threaded each 1493.75
18.94.20 For 48.60 mm
mm outer diaxx 40 mm nominal dia
40 mm dia threaded each 1536.45
18.94.21
18.94.21 For 48.60 mm
mm outer diaxx 50
50 mm
mm nominal dia
dia threaded each 1586.25
18.95 Providing
Providing and fixing required
and fixing required Stainless
Stainless Steel
Steel Fitting of press
Fitting of fit design
press fit design
of grade AISI
of grade AISI 304 conforming to
304 conforming to JWWA
JWWA G116 standard with
G116 standard with V-profile
V-profile or
or
M-profile
M-profile and with O-ring
and with sealing gasket
O-ring sealing gasket of
of EPDM
EPDM material of required
material of dia
required dia
as per direction of Engineer-in-charge.
as
Female Thread Tee
18.95.1
18.95.1 For 15.88 mm
For mm outer dia x15 mm nominal dia
x15 mm dia threaded each 277.40
18.95.2 For 22.22 mm
mm outer diaxx 15
15 mm
mm nominal dia
dia threaded each 305.85
18.95.3 For 22.22 mm
mm outer diaxx 20 mm nominal dia
20 mm dia threaded each 320.10
18.95.4 For 28.58 mm
mm outer diaxx 15
15 mm
mm nominal dia
dia threaded each 405.45
18.95.5 For 28.58 mm
mm outer diaxx 20 mm nominal dia
20 mm dia threaded each 419.70
18.95.6 For 28.58 mm
mm outer diaxx 25 mm nominal dia
25 mm dia threaded each 433.90
18.95.7 mm outer diaxx 15
For 34.00 mm 15 mm
mm nominal dia
dia threaded each 647.30
18.95.8 mm outer diaxx 20
For 34.00 mm mm nominal dia
20 mm dia threaded each 690.00
18.95.9 mm outer diaxx 25
For 34.00 mm mm nominal dia
25 mm dia threaded each 732.65

300
300 SUB HEAD:: 18.0 WATER SUPPLY
SUB SUPPLV
Code No Description Unit Rate
18.95.10 mm outer diaxx 32
For 34.00 mm 32 mm
mm nominal dia
dia threaded each 775.35
18.95.11
18.95.11 For 42.70 mm
For mm outer diaxx 15
15 mm
mm nominal dia
dia threaded each 995.85
18.95.12 For 42.70 mm
mm outer diaxx 20 mm nominal dia
20 mm dia threaded each 1010.05
18.95.13 For 42.70 mm
mm outer diaxx 25 mm nominal dia
25 mm dia threaded each 1038.50
18.95.14 For 42.70 mm
mm outer diaxx 32 mm nominal dia
32 mm dia threaded each 1066.95
18.95.15 For 42.70 mm
mm outer diaxx 40 mm nominal dia
40 mm dia threaded each 1145.25
18.95.16 For 48.60 mm
mm outer diaxx 15
15 mm
mm nominal dia
dia threaded each 1287.50
18.95.17 For 48.60 mm
mm outer diaxx 20 mm nominal dia
20 mm dia threaded each 1301.70
18.95.18 For 48.60 mm
mm outer diaxx 25 mm nominal dia
25 mm dia threaded each 1323.05
18.95.19 For 48.60 mm
mm outer diaxx 32 mm nominal dia
32 mm dia threaded each 1394.20
18.95.20 For 48.60 mm
mm outer diaxx 40 mm nominal dia
40 mm dia threaded each 1429.75
18.95.21
18.95.21 For 48.60 mm
mm outer diaxx 50 mm nominal dia
50 mm dia threaded each 1543.55
18.95A Providing and fixing
Providing and fixing required
required Stainless
Stainless Steel
Steel Fitting
Fitting of
of press fit design
press fit design of
of
grade 316L as perperIS
IS:: 6911:2017 and
and conforming to to EN-10312 standards
with V-profile
with V-profile and with O-ring
and with sealing gasket
O-ring sealing of EPDM
gasket of EPDM material of required
material of required
as per direction of Engineer-in-charge.
dia as
Female Thread Tee
18.95A.1
18.95A.1 For
For 15
15 mm outer dia
mm outer diaxx 1/2”
1/2” nominal dia threaded
nominal dia threaded each 889.15
18.95A.2 For 22 mm
For 22 outer dia
mm outer diaxx 1/2”
1/2” nominal dia threaded
nominal dia threaded each 967.40
18.95A.3 For 22 mm
For 22 outer diax
mm outer dia x 3/4”
3/4” nominal dia threaded
nominal dia threaded each 1095.45
18.95A.4 For 28 mm
For 28 outer dia
mm outer diaxx 1/2”
1/2” nominal dia threaded
nominal dia threaded each 1159.45
18.95A.5 For 28 mm
For 28 outer dia
mm outer diaxx 3/4”
3/4" nominal dia threaded
nominal dia threaded each 1202.15
18.95A.6 For 28 mm
For 28 outer dia
mm outer diaxx 1”
1” nominal dia threaded
nominal dia threaded each 1330.15
18.95A.7 For
For 35
35 mm outer dia
mm outer diaxx 1/2”
1/2“ nominal dia threaded
nominal dia threaded each 1337.30
18.95A.8 For
For 35
35 mm outer dia
mm outer diaxx 1-1/4”
1-1/4” nominal dia threaded
nominal dia threaded each 1842.30
18.95A.9 For 42 mm
For 42 outer dia
mm outer diaxx 1-1/4”
1-1/4” nominal dia threaded
nominal dia threaded each 2141.05
18.95A.10 For
For 54
54 mm outer dia
mm outer diaxx 1-1/2”
1-1/2” nominal dia threaded
nominal dia threaded each 3058.65
18.95A.11
18.95A.11 For
For 54
54 mm outer dia
mm outer diaxx 2"
2” nominal dia threaded
nominal dia threaded each 3670.40
18.96 Providing
Providing and fixing required
and fixing required Stainless Steel Fitting
Stainless Steel of press
Fitting of fit design
press fit design
of grade AISI
of grade AISI 304 conforming to
304 conforming to JWWA
JWWA G116 standard with
G116 standard with V-profile
V-profile or
or
M-profile
M-profile and with O-ring
and with sealing gasket
O-ring sealing gasket of
of EPDM
EPDM material of required
material of dia
required dia
as per direction of Engineer-in-charge.
as
Female Thread Connector/ Adapter
18.96.1
18.96.1 mm outer diaxx 15 mm
For 15.88 mm
For mm nominal dia
dia threaded each 264.60
18.96.2 For 22.22 mm
mm outer diaxx 15 mmnominal dia
diathreaded
threaded each 291.65
18.96.3 For 22.22 mm
mm outer diaxx 20 mm nominal dia
20 mm dia threaded each 337.15
18.96.4 For 28.58 mm
mm outer diaxx 15 mm
mm nominal dia
dia threaded each 394.05
18.96.5 For 28.58 mm
mm outer diaxx 20 mm nominal dia
20 mm dia threaded each 412.55
18.96.6 For 28.58 mm
mm outer diaxx 25 mm nominal dia
25 mm dia threaded each 505.05
18.96.7 mm outer diaxx 25
For 34.00 mm mm nominal dia
25 mm dia threaded each 640.20
18.96.8 mm outer diaxx 32
For 34.00 mm 32 mm
mm nominal dia
dia threaded each 768.25
18.96.9 mm outer diaxx 32
For 42.70 mm 32 mm
mm nominal dia
dia threaded each 953.15
18.96.10 For 42.70 mm
mm outer diaxx 40 mm nominal dia
40 mm dia threaded each 1002.95
18.96.11
18.96.11 For 48.60 mm
For mm outer diaxx 40 mm nominal dia
40 mm dia threaded each 1287.50

SUB HEAD:: 18.0 WATER SUPPLY


SUB SUPPL•Y 301
Code No Description Unit Rate
18.96.12 For 48.60 mm
mm outer diaxx 50
50 mm
mm nominal dia
dia threaded each 1387.05
18.96A Providing and fixing
Providing and fixing required
required Stainless
Stainless Steel
Steel Fitting
Fitting of
of press fit design
press fit design of
of
grade 316L as perperIS
IS:: 6911:2017 and
and conforming to to EN-10312 standards
with V-profile
with V-profile and with O-ring
and with sealing gasket
O-ring sealing of EPDM
gasket of EPDM material of required
material of required
as per direction of Engineer-in-charge.
dia as
Female Thread Connector/ Adapter
18.96A.1
18.96A.1 For
For 15
15 mm outer dia
mm outer diaxx 1/2”
1/2” mm
mm nominal
nominal dia threaded
dia threaded each 697.10
18.96A.2 For 22 mm
For 22 outer dia
mm outer diaxx 1/2”
1/2” mm
mm nominal
nominal dia threaded
dia threaded each 782.45
18.96A.3 For 22 mm
For 22 outer dia
mm outer diaxx 3/4”
3/4” mm
mm nominal
nominal dia threaded
dia threaded each 917.60
18.96A.4 For 28 mm
For 28 outer dia
mm outer diaXX 1”
1” nominal dia threaded
nominal dia threaded each 1515.10
18.96A.5 For
For 35
35 mm outer dia
mm outer diaXX 1-1/4”
1-1/4” nominal
nominal dia threaded
dia threaded each 1621.80
18.96A.6 For 42 mm
For 42 outer dia
mm outer diaXX 1-1/2”
1-1/2” nominal
nominal dia threaded
dia threaded each 2489.60
18.96A.7 For
For 54
54 mm outer dia
mm outer diaXX 2”
2” nominal dia threaded
nominal dia threaded each 3819.80
18.97 Providing
Providing and fixing required
and fixing required Stainless
Stainless Steel
Steel Fitting of press
Fitting of fit design
press fit design
of
of grade AISI 304
grade AISI 304 conforming to JWWA
conforming to JWWA G116 standard with
G116 standard with V-profile
V-profile or
or
M-profile
M-profile and with O-ring
and with O-ring sealing
sealing gasket of EPDM
gasket of EPDM material
material of
of required dia
required dia
as per direction of Engineer-in-charge.
as
Male Thread Connector/ Adapter
18.97.1
18.97.1 For 15.88 mm
For mm outer diaxx 15
15 mm
mm nominal dia
dia threaded each 250.40
18.97.2 For 22.22 mm
mm outer diaxx 15
15 mm
mm nominal dia
dia threaded each 268.85
18.97.3 For 22.22 mm
mm outer diaxx 20 mm nominal dia
20 mm dia threaded each 300.20
18.97.4 For 28.58 mm
mm outer diaxx 20 mm nominal dia
20 mm dia threaded each 458.10
18.97.5 For 28.58 mm
mm outer diaxx 25 mm nominal dia
25 mm dia threaded each 460.95
18.97.6 mm outer diaxx 25
For 34.00 mm mm nominal dia
25 mm dia threaded each 675.75
18.97.7 mm outer diaxx 32
For 34.00 mm 32 mm
mm nominal dia
dia threaded each 803.80
18.97.8 For 42.70 mm
mm outer diaxx 32
32 mm
mm nominal dia
dia threaded each 1017.20
18.97.9 For 42.70 mm
mm outer diaxx 40 mm nominal dia
40 mm dia threaded each 1038.50
18.97.10 For 48.60 mm
mm outer diaxx 40 mm nominal dia
40 mm dia threaded each 1330.15
18.97.11
18.97.11 For 48.60 mm
For mm outer diaxx 50
50 mm
mm nominal dia
dia threaded each 1621.80
18.97A Providing and fixing
Providing and fixing required
required Stainless
Stainless Steel
Steel Fitting
Fitting of
of press fit design
press fit design of
of
grade 316L as perperIS
IS:: 6911:2017
6911 :2017 and
and conforming toto EN-10312 standard
with V-profile
with V-profile and
and with
with O-ring sealing gasket
O-ring sealing gasket of
of EPDM
EPDM material
material of
of required
required
as per direction of Engineer-in-charge.
dia as
Male Thread Connector/ Adapter
18.97A.1
18.97A.1 For
For 15
15 mm outer dia
mm outer diaXX 1/2”
1/2” nominal
nominal dia threaded
dia threaded each 640.20
18.97A.2 For 22 mm
For 22 outer dia
mm outer diaXX 1/2”
1/2” nominal
nominal dia threaded
dia threaded each 761.10
18.97A.3 For
For 22
22 mm outer dia
mm outer diaXX 3/4”
3/4” nominal
nominal dia threaded
dia threaded each 803.80
18.97A.4 For 28 mm
For 28 outer dia
mm outer diaXX 1”
1” nominal
nominal dia threaded
dia threaded each 1052.75
18.97A.5 For
For 35
35 mm outer dia
mm outer diaXX 1-1/4”
1-1/4” nominal
nominal dia threaded
dia threaded each 1543.55
18.97A.6 For 42 mm
For 42 outer dia
mm outer diaXX 1-1/2”nominal
1-1/2”nominaI dia threaded
dia threaded each 2247.75
18.97A.7 For
For 54
54 mm outer dia
mm outer diaXX 2”
2” nominal
nominal dia threaded
dia threaded each 3016.00
18.98 Providing
Providing and fixing required
and fixing required Stainless
Stainless Steel
Steel Fitting
Fitting of
of press fit design
press fit design
of grade
of grade AISI
AISI 304
304 conforming
conforming to
to JWWA
JWWA G116 standard with
G116 standard with V-profile
V-profile or
or
M-profile and with
M-profile and with O-ring sealing gasket
O-ring sealing gasket of
of EPDM
EPDM material of required
material of dia
required dia
as
as per direction of Engineer-in-charge.
Valve Connector
Valve Connector

302
302 SUB HEAD:: 18.0 WATER SUPPLY
SUB SUPPLV
Code No Description Unit Rate
18.98.1
18.98.1 For 15.88 mm
For mm outer diaxx 15
15 mm
mm nominal dia
dia threaded each 317.25
18.98.2 For 22.22 mm
mm outer diaxx 15
15 mm
mm nominal dia
dia threaded each 364.20
18.98.3 For 22.22 mm
mm outer diaxx 20 mm nominal dia
20 mm dia threaded each 395.50
18.98.4 For 28.58 mm
mm outer diaxx 25 mm nominal dia
25 mm dia threaded each 604.60
18.98.5 mm outer diaxx 32
For 34.00 mm mm nominal dia
32 mm dia threaded each 917.60
18.98.6 For 42.70 mm
mm outer diaxx 40 mm nominal dia
40 mm dia threaded each 1298.85
18.98.7 For 48.60 mm
mm outer diaxx 50
50 mm
mm nominal dia
dia threaded each 1756.95
18.99 Providing
Providing and fixing required
and fixing required Stainless
Stainless Steel
Steel Fitting of press
Fitting of fit design
press fit design
of
of grade AISI 304
grade AISI 304 conforming to JWWA
conforming to JWWA G116 standard with
G116 standard with V-profile
V-profile or
or
M-profile
M-profile and with O-ring
and with sealing gasket
O-ring sealing of EPDM
gasket of EPDM material
material of
of required dia
required dia
as per direction of Engineer-in-charge.
as
Female Threaded Elbow 90°
90°
18.99.1
18.99.1 For 15.88 mm
For mm outer diax 15 mm
dia x 15 mm nominal dia
dia threaded each 270.30
18.99.2 For 22.22 mm
mm outer diaxx 15
15 mm
mm nominal dia
dia threaded each 305.85
18.99.3 For 22.22 mm
mm outer diaxx 20 mm nominal dia
20 mm dia threaded each 341.45
18.99.4 For 25.58 mm
mm outer diaxx 25 mm nominal dia
25 mm dia threaded each 369.90
18.99.5 For 34.00 mm
mm outer diaxx 32 mm nominal dia
32 mm dia threaded each 476.60
18.99.6 For 42.70 mm
mm outer diaxx 32 mm nominal dia
32 mm dia threaded each 754.00
18.99.7 For 42.70 mm
mm outer diaxx 40 mm nominal dia
40 mm dia threaded each 754.00
18.99.8 For 48.60 mm
mm outer diax
dia x 40 mm nominal dia
40 mm dia threaded each 1123.90
18.99.9 For 48.60 mm
mm outer diaxx 50
50 mm
mm nominal dia
dia threaded each 1123.90
18.99A Providing and fixing
Providing and fixing required
required Stainless
Stainless Steel
Steel Fitting
Fitting of
of press fit design
press fit design of
of
grade 316L as perperIS
IS:: 6911:2017
6911 :2017 and
and conforming toto EN-10312 standard
with V-profile
with V-profile and
and with
with O-ring sealing gasket
O-ring sealing gasket of
of EPDM
EPDM material of required
material of required
as per direction of Engineer-in-charge.
dia as
Female Threaded Elbow 90°
90°
18.99A.1
18.99A.1 For
For 15
15 mm outer dia
mm outer diaXX 1/2”
1/2” nominal
nominal dia threaded
dia threaded each 1017.20
18.99A.2 For 22 mm
For 22 outer dia
mm outer diaXX 3/4”
3/4” nominal
nominal dia threaded
dia threaded each 1365.70
18.99A.3 For 28 mm
For 28 outer dia
mm outer diaXX 1”
1” nominal
nominal dia threaded
dia threaded each 1877.90
18.99A.4 For
For 35
35 mm outer dia
mm outer diaXX 1-1/4”
1-1/4” nominal
nominal dia threaded
dia threaded each 3051.55
18.99A.5 For 42 mm
For 42 outer dia
mm outer diaXX 1-1/2”
1-1/2” nominal
nominal dia threaded
dia threaded each 3321.85
18.99A.6 For
For 54
54 mm outer dia
mm outer diaXX 2”
2” nominal
nominal dia threaded
dia threaded each 5135.70
18.100 Providing and fixing required Stainless Steel Fitting of
Providing and fixing required Stainless Steel Fitting of press fit design
press fit design
of grade
of grade AISI
AISI 304 conforming to
304 conforming to JWWA
JWWA G116 standard with
G116 standard with V-profile
V-profile or
or
M-profile and with
M-profile and with O-ring
O-ring sealing gasket of
sealing gasket of EPDM
EPDM material of required
material of dia
required dia
as
as per direction of Engineer-in-charge.
Male Threaded Elbow 90° 90°
18.100.1
18.100.1 For 15.88 mmmm outer diaxx 1515 mm
mm nominal diadia threaded each 325.80
18.100.2 For 22.22 mmmm outer diaxx 1515 mm
mm nominal diadia threaded each 355.65
18.100.3 For 22.22 mmmm outer diaxx 20 mm nominal dia
20 mm dia threaded each 377.00
18.100.4 For 28.58 mm
mm outer diaxx 25 mm nominal dia
25 mm dia threaded each 405.45
18.100.5 mm outer diaxx 25
For 34.00 mm mm nominal dia
25 mm dia threaded each 448.15
18.100.6 mm outer diaxx 32
For 34.00 mm 32 mm
mm nominal dia
dia threaded each 448.15
18.100.7 For 42.70 mm
mm outer diaxx 32
32 mm
mm nominal dia
dia threaded each 682.85
18.100.8 For 42.70 mm
mm outer diaxx 40 mm nominal dia
40 mm dia threaded each 754.00

SUB HEAD:: 18.0 WATER SUPPLY


SUB SUPPL•Y 303
Code No Description Unit Rate
18.100.9 For 48.60 mm
mm outer diaxx 40 mm nominal dia
40 mm dia threaded each 1088.30
18.100.10 For 48.60 mm
mm outer diaxx 50
50 mm
mm nominal dia
dia threaded each 1187.90
18.100.A Providing and fixing
Providing and fixing required
required Stainless
Stainless Steel
Steel Fitting
Fitting of
of press fit design
press fit design of
of
grade 316L as perperIS
IS:: 6911:2017
6911 :2017 and
and conforming toto EN-10312 standard
with V-profile
with V-profile and with O-ring
and with sealing gasket
O-ring sealing of EPDM
gasket of EPDM material of required
material of required
as per direction of Engineer-in-charge.
dia as
Male Threaded Elbow 90°
18.100A.1
18.100A.1 For
For 15
15 mm outer dia
mm outer diaXX 1/2”
1/2” nominal dia threaded
nominal dia threaded each 832.25
18.100A.2 For 22 mm
For 22 outer dia
mm outer diaXX 3/4”
3/4” nominal dia threaded
nominal dia threaded each 1251.95
18.100A.3 For 28 mm
For 28 outer dia
mm outer diaXX 1”
1” nominal dia threaded
nominal dia threaded each 1664.50
18.100A.4 For
For 35
35 mm outer dia
mm outer diaXX 1-1/4”
1-1/4” nominal
nominal dia threaded
dia threaded each 2290.45
18.100A.5 For 42 mm
For 42 outer dia
mm outer diaXX 1-1/2”
1-1/2” nominal
nominal dia threaded
dia threaded each 4196.80
18.100A.6 For
For 54
54 mm outer dia
mm outer diaXX 2”
2" mm
mm nominal dia threaded
nominal dia threaded each 4772.95
18.101
18.101 Providing
Providing and fixing required
and fixing required Stainless Steel Fitting
Stainless Steel of press
Fitting of fit design
press fit design
of grade AISI
of grade AISI 304 conforming to
304 conforming to JWWA
JWWA G116 standard with
G116 standard with V-profile
V-profile or
or
M-profile
M-profile and with O-ring
and with O-ring sealing gasket of
sealing gasket of EPDM
EPDM material of required
material of dia
required dia
as per direction of Engineer-in-charge.
as
Cap
Cap
18.101.1
18.101.1 mm outer dia pipe
For 15.88 mm each 58.35
18.101.2 For 22.22 mm
mm outer dia pipe each 85.35
18.101.3 For 28.58 mm
mm outer dia pipe each 122.35
18.101.4 mm outer dia pipe
For 34.00 mm each 234.75
18.101.5 For 42.70 mm
mm outer dia pipe each 342.85
18.101.6 For 48.60 mm
mm outer dia pipe each 426.80
18.101A
18.101A Providing and fixing
Providing and fixing required
required Stainless
Stainless Steel
Steel Fitting of press
Fitting of fit design
press fit design of
of
grade 316L as perperIS
IS:: 6911:2017 and
and conforming toto EN-10312 standard
with V-profile
with V-profile and
and with
with O-ring
O-ring sealing
sealing gasket
gasket of
of EPDM
EPDM material
material of
of required
required
dia as
as per direction of Engineer-in-charge.
Cap
Cap
18.101 A.1 For 15
18.101A.1 15 mm
mm outer dia pipe each 505.05
18.101 A.2 For 22
18.101A.2 22 mm
mm outer dia pipe each 654.40
18.101 A.3 For 28
18.101A.3 mm outer dia pipe
28 mm each 818.00
18.101 A.4 For 35
18.101A.4 35 mm
mm outer dia pipe each 1145.25
18.101 A.5 For 42
18.101A.5 mm outer dia pipe
42 mm each 2489.60
18.101 A.6
18.101A.6 54 mm
For 54 mm outer dia pipe each 2738.55
18.102 Providing and fixing
Providing and fixing required
required Stainless
Stainless Steel
Steel Fitting
Fitting of
of press fit design
press fit design
of grade
of grade AISI
AISI 304
304 conforming
conforming to
to JWWA
JWWA G116
G116 standard with V-profile
standard with V-profile or
or
M-profile and with
M-profile and with O-ring
O-ring sealing gasket of
sealing gasket of EPDM
EPDM material of required
material of dia
required dia
as
as per direction of Engineer-in-charge.
Pipe Bridge
18.102.1
18.102.1 mm outer dia pipe
For 15.88 mm each 136.55
18.102.2 mm outer dia pipe
For 22.22 mm each 240.45
18.102.3 mm outer dia pipe
For 28.58 mm each 386.95

304
304 SUB HEAD:: 18.0 WATER SUPPLY
SUB SUPPLV
Code No Description Unit Rate
18.102A Providing and fixing
Providing and fixing required
required Stainless
Stainless Steel
Steel Fitting
Fitting of
of press fit design
press fit design of
of
grade 316L as perperIS
IS:: 6911:2017
6911 :2017 and
and conforming toto EN-10312 standard
with V-profile
with V-profile and with O-ring
and with sealing gasket
O-ring sealing of EPDM
gasket of EPDM material of required
material of required
as per direction of Engineer-in-charge.
dia as
Pipe Bridge
18.102A.1
18.102A.1 mm outer dia pipe
For 15 mm each 654.40
18.102A.2 For 22 mm outer dia pipe
22 mm each 1764.10
18.102A.3 For 28 mm outer dia pipe
28 mm each 2425.60
18.103 Providing and fixing
Providing and fixing required
required Stainless
Stainless Steel
Steel Fitting
Fitting of
of press fit design
press fit design of
of
grade 316L as perperIS
IS:: 6911:2017
6911 :2017 and
and conforming toto EN-10312 standard
with V-profile
with V-profile and with O-ring
and with sealing gasket
O-ring sealing of EPDM
gasket of EPDM material of required
material of required
as per direction of Engineer-in-charge.
dia as
Male
Male Union
Union
18.103.1
18.103.1 For
For 15
15 mm outer dia
mm outer diaXX 1/2”
1/2” nominal dia threaded
nominal dia threaded each 1408.40
18.103.2 For 22 mm
For 22 outer dia
mm outer diaXX 1/2”
1/2” nominal dia threaded
nominal dia threaded each 1422.65
18.103.3 For 22 mm
For 22 outer dia
mm outer diaXX 3/4”
3/4” nominal dia threaded
nominal dia threaded each 1628.90
18.103.4 For 28 mm
For 28 outer dia
mm outer diaXX 1”
1” nominal dia threaded
nominal dia threaded each 2873.70
18.103.5 For
For 35
35 mm outer dia
mm outer diaXX 1-1/4”
1-1/4” nominal
nominal dia threaded
dia threaded each 3001.75
18.103.6 For 42 mm
For 42 outer dia
mm outer diaXX 1-1/2”
1-1/2” nominal
nominal dia threaded
dia threaded each 3385.85
18.103.7 For
For 54
54 mm outer dia
mm outer diaXX 2”
2” nominal dia threaded
nominal dia threaded each 5861.25
18.104 Providing and fixing
Providing and fixing required
required Stainless
Stainless Steel
Steel Fitting
Fitting of
of press fit design
press fit design of
of
grade 316L as perperIS
IS:: 6911:2017 and
and conforming toto EN-10312 standard
with V-profile
with V-profile and
and with
with O-ring sealing gasket
O-ring sealing gasket of
of EPDM
EPDM material of required
material of required
as per direction of Engineer-in-charge.
dia as
Female
Female Union
Union
18.104.1
18.104.1 For 22 mm
For 22 outer dia
mm outer diaXX 3/4"
3/4” nominal
nominal dia threaded
dia threaded each 1508.00
18.104.2 For 28 mm
For 28 outer dia
mm outer diaXX 1”
1” nominal
nominal dia threaded
dia threaded each 2034.35
18.105 Providing and fixing
Providing and fixing required
required Stainless
Stainless Steel
Steel Fitting of press
Fitting of fit design
press fit design of
of
grade 316L as perperIS
IS:: 6911:2017 and
and conforming toto EN-10312 standard
with V-profile
with V-profile and
and with
with O-ring
O-ring sealing
sealing gasket
gasket of
of EPDM
EPDM material
material of
of required
required
dia as
as per direction of Engineer-in-charge.
Female Transition Elbow// FTE
FTE
18.105.1
18.105.1 For
For 15
15 mm outer dia
mm outer diaXX 1/2”
1/2” nominal
nominal dia threaded
dia threaded each 1031.40
18.105.2 For 22 mm
For 22 outer dia
mm outer diaXX 1/2”
1/2” nominal
nominal dia threaded
dia threaded each 1379.95
18.105.3 For
For 22
22 mm outer dia
mm outer diaXX 3/4”
3/4” nominal
nominal dia threaded
dia threaded each 1429.75

SUB HEAD:: 18.0 WATER SUPPLY


SUB SUPPi.Y 305
SUB HEAD
SUB HEAD:: 19.0
DRAINAGE
19.0 DRAINAGE

Code No Description Unit Rate


NOTE:: - The
NOTE The rates given forall
for all the
the items under sub-head ‘Drainage’ are
are
applicable to work executed in soils above sub- soil water level. Extra
has to
allowance has to be made for
for work under sub- soil water level.
STONE WARE PIPES AND
AND FITTINGS
19.1
19.1 Providing,
Providing, laying
laying and jointing glazed
and jointing glazed stoneware
stoneware pipes class SP-1
pipes class with stiff
SP-1 with stiff
mixture of cement
mixture of cement mortar
mortar in the proportion
in the of 1:1
proportion of 1:1 (1
(1 cement
cement::11 fine
fine sand)
sand)
including testing of joints etc. complete
complete::
19.1.1
19.1.1 100 mm
100 mm diameter metre 443.60
19.1.2 150 mm
150 mm diameter metre 695.80
19.1.3 200 mm diameter
200 mm metre 970.35
19.1.4 250 mm diameter
250 mm metre 1505.60
19.1.5 300 mm
300 mm diameter metre 2064.15
19.2 Providing and
and laying cement concrete 1:5:10 (1
(1 cement
cement:5 : 5 coarse sand
: 10 graded stone
10 graded stone aggregate
aggregate 40
40 mm
mm nominal size) all-round
nominal size) all-round S.W.
S.W. pipes
pipes
bed concrete as
including bed as per standard design
design::
19.2.1
19.2.1 100 mm
100 mm diameter S.W. pipe metre 964.75
19.2.2 150 mm
150 mm diameter S.W. pipe metre 1179.85
19.2.3 200 mm diameter S.W. pipe
200 mm metre 1375.45
19.2.4 250 mm diameter S.W. pipe
250 mm metre 1590.55
19.3 Providing and
and laying cement concrete 1:5:10 (1
(1 cement
cement:5: 5 coarse sand:
sand :
10 graded stone
10 graded stone aggregate
aggregate 40
40 mm
mm nominal size) up
nominal size) to haunches
up to of S.W.
haunches ofS.W.
bed concrete as per standard design:
pipes including bed design :
19.3.1
19.3.1 100 mm
100 mm diameter S.W. pipe metre 458.50
19.3.2 150 mm
150 mm diameter S.W. pipe metre 743.10
19.3.3 200 mm diameter S.W. pipe
200 mm metre 873.50
19.3.4 250 mm diameter S.W. pipe
250 mm metre 1016.90
19.3.5 300 mm diameter S.W. pipe
300 mm metre 1173.35
19.4 Providing
Providing and fixing square-mouth
and fixing square-mouth S.W.S.W. gully trap class
gully trap class SP-1
SP-1 complete
complete
with C.I. grating brick masonry chamber with water tight C.I. cover with
frame of300x
frame of 300 x 300
300 mm size (inside)
mm size the weight
(inside) the weight of cover to
ofcover to be
be not
not less than
less than
4.50 kg and
and frame to not less than 2.70 kg as per standard design:
to be not
19.4.1
19.4.1 100x100 mmmm sizeP
size P type
19.4.1.1
19.4.1.1 With common
With common burnt clay F.P.S.
burnt clay F.P.S. (non
(non modular)
modular
) each 2707.65
bricks of class designation 7.5
19.4.1.2 With Sewer bricks conforming to IS:: 4885
to IS each 2685.20
19.4.2 150xx 100
150 100 mm
mm sizeP
size P type
19.4.2.1
19.4.2.1 With common
With common burnt clay F.P.S.
burnt clay F.P.S. (non
(non modular)
modular
) each 2734.20
bricks of class designation 7.5
19.4.2.2 With sewer bricks conforming to IS:: 4885
to IS each 2711.70
19.4.3 180x150 mmmm sizeP
size P type
19.4.3.1
19.4.3.1 With common
With common burnt clay F.P.S.
burnt clay F.P.S. (non
(non modular)
modular
) each 2802.15
bricks of class designation 7.5
19.4.3.2 With Sewer bricks conforming to IS:: 4885
to IS each 2779.65

SUB HEAD : 19.0 DRAINAGE 309


Code No Description Unit Rate
19.5 Dismantling ofold
of old S.W. pipes including breaking ofjoints and bed
of joints and bed concrete
stacking of useful materials near the site within 50
50 mm lead and
and disposal of
unserviceable materials into municipal dumps:
dumps :
19.5.1
19.5.1 100 mm
100 mm diameter metre 89.00
19.5.2 150 mm
150 mm diameter metre 98.45
19.5.3 200 mm diameter
200 mm metre 104.70
19.5.4 250 mm diameter
250 mm metre 111.00
19.5.5 300 mm diameter
300 mm metre 117.25
19.5.6 350 mm diameter
350 mm metre 135.05
19.5.7 400 mm diameter
400 mm metre 147.65
19.5.8 450 mm diameter
450 mm metre 153.90
19.6 Providing and laying
Providing and laying non-pressure
non-pressure NP2
NP2 class
class (light
(light duty)
duty) R.C.C.
R.C.C.
pipes with collars jointed with stiff mixture of cement mortar in the the
proportion
proportion of
of11:2
:2 (1 cement : 2 fine
(1 cement:2 fine sand)
sand) including testing of
including testing of joints
joints
complete::
etc. complete
19.6.1
19.6.1 100 mm
100 mm dia. R.C.C. pipe metre 507.05
19.6.2 150 mm
150 mm dia. R.C.C. pipe metre 556.45
19.6.3 250 mm dia. R.C.C. pipe
250 mm metre 899.80
19.6.4 300 mm dia. R.C.C. pipe
300 mm metre 994.30
19.6.5 450 mm dia. R.C.C. pipe
450 mm metre 1620.95
19.6.6 500 mm dia. R.C.C. pipe
500 mm metre 1918.90
19.6.7 600
600 mmmm dia. R.C.C. pipe metre 2243.40
19.6.8 700
700 mmmm dia. R.C.C. pipe metre 2932.50
19.6.9 800
800 mmmm dia. R.C.C. pipe metre 3511.95
19.6.10 900
900 mmmm dia. R.C.C. pipe metre 4750.85
19.6.11
19.6.11 1000 mmmm dia. R.C.C. pipe metre 5562.60
19.6.12 1100 mmmm dia. R.C.C. pipe metre 6276.60
19.6.13 1200 mmmm dia. R.C.C. pipe metre 7102.15
19.7 Constructing brick masonry manhole in cement mortar
Constructing mortar11:4 :4(( 11 cement
:44 coarse
coarse sand
sand)) with
with R.C.C.
R.C.C. top top slab
slab with
with 1:1.5:3
1:1.5:3 mix
mix (1(1 cement
cement:: 1.5 1.5
coarse sand (zone-III)
coarse sand (zone-III)::3 3 graded
graded stone
stone aggregate
aggregate 2020 mmmm nominal
nominal size),
size),
foundation concrete
foundation concrete11:4:8
:4:8 mix
mix (1 cement : 4 coarse
(1 cement:4 coarse sand
sand (zone-III)
(zone-III)::8 8
graded
graded stone aggregate 40
stone aggregate 40 mm
mm nominal size), inside
nominal size), inside plastering
plastering 1212 mm
mm
thick with
thick with cement
cement mortar
mortar 1:3
1:3 (1 cement :3 3 coarse
(1 cement: sand) finished
coarse sand) finished with
with
floating coat
floating coat of
of neat
neat cement
cement and and making
making channels
channels in cement concrete
in cement concrete
(1 cement:
1:2:4 (1 cement : 22 coarse sand ::4 4 graded stone aggregate 20 20 mm
mm
nominal
nominal size) finished witha
size) finished with a floating
floating coat
coat of
of neat
neat cement
cement complete
complete as as per
per
design::
standard design
19.7.1
19.7.1 Inside size 90x80 cm cm and 45 cm cm deep including C.I.
cover with
cover with frame
frame (light duty) 455x610
(lig ht duty) 455x610 mm mm internal
internal
dimensions, total weight of of cover and
and frame to not
to be not
less than 38 38 kg (weight of cover 23 kg and and weight
weight ofof
frame 15
frame 15 kg)
kg)::
19.7.1.1
19.7.1.1 With common
With common burnt clay F.P.S.
burnt clay F.P.S. (non
(non modular)
modular
) each 12770.55
bricks of class designation 7.5
19.7.1.2 With Sewer bricks conforming to IS:: 4885
to IS each 12711.80

310
310 SUB HEAD : 19.0 DRAINAGE
Code No Description Unit Rate
19.7.2 Inside size 120x90 cmcm and 90 cm cm deep including C.I. cover
with frame
with frame (medium duty) 500
(medium duty) 500 mm mm internal diameter, total
internal diameter, total
weight of
ofcover
cover and
and frame to not less than 116 kg (weight
to be not
of cover
of cover 58
58 kg
kg and weight of
and weight of frame
frame 5858 kg)
kg)::
19.7.2.1
19.7.2.1 With common
With common burnt
burnt clay
clay F.P.S.
F.P.S. (non
(non modular)
modular
) each 26405.50
bricks of class designation 7.5
19.7.2.2 With Sewer bricks conforming to IS:: 4885
to IS each 26244.70
19.7.3 Inside size 120x90 cmcm and 90 cm cm deep including C.I. cover
with frame
with frame (heavy
(heavy duty)
duty) 560
560 mm mm internal diameter, total
internal diameter, total
weight of and frame tobe
of cover and notless
to be not less than 208
208 kg (weight
of cover
of cover 108
108 kg
kg and weight of
and weight of frame
frame 100
100 kg)
kg)::
19.7.3.1
19.7.3.1 With common
With common burnt
burnt clay
clay F.P.S.
F.P.S. (non
(non modular)
modular
) each 32857.85
bricks of class designation 7.5
19.7.3.2 With Sewer bricks conforming to IS IS:: 4885 each 32719.50
19.8 Extra fordepth
for depth formanholes:
for manholes :
19.8.1
19.8.1 Size 90x80 cm
cm
19.8.1.1
19.8.1.1 With common
With common burnt clay F.P.S.
burnt clay F.P.S. (non
(non modular)
modular
) metre 8825.40
bricks of class designation 7.5
19.8.1.2 With Sewer bricks conforming to IS:: 4885
to IS metre 8654.25
19.8.2 Size 120x90 cm
cm
19.8.2.1
19.8.2.1 With common
With common burnt clay F.P.S.
burnt clay F.P.S. (non
(non modular)
modular
) metre 10585.50
bricks of class designation 7.5
19.8.2.2 With Sewer bricks conforming to IS:: 4885
to IS metre 10381.45
19.9 Constructing brick masonry circular type manhole 0.91 0.91 mm internal dia
dia at
bottom and
and 0.56 m m dia
dia at
at top in cement mortar
mortar11:4
:4 (1
(1 cement:4
cement : 4 coarse
sand), inside
sand), inside cement
cement plaster
plaster 12
12 mm thick with
mm thick with cement
cement mortar
mortar 1:3 (1 cement
1:3(1 cement
:33 coarse sand) finished
coarse sand) finished witha
with a floating
floating coat
coat of
of neat
neat cement, foundation
cement, foundation
concrete 1:3:6 mixmix (1
(1 cement
cement::3 3 coarse sand:6
sand : 6 graded stone aggregate
40 mm
40 mm nominal
nominal size),
size), and
and making
making necessary
necessary channel
channel in cement concrete
in cement concrete
(1 cement:
1:2:4 (1 cement : 22 coarse sand sand::4 4 graded stone aggregate 20 mm
20 mm
nominal size) finished
nominal size) finished witha
with a floating
floating coat
coat of
of neat
neat cement, all complete
cement, all complete as
as
per standard design:
design :
19.9.1
19.9.1 0.91
0.91 m m deep with S.F.R.C. cover and and frame (heavy duty,
HD-20 grade designation)
HD-20 grade designation) 560560 mmmm internal diameter
internal diameter
conforming to to I.S. 12592, total weight ofof cover and
and frame to to
be
be not
not less than 182
less than 182 kg., fixed in
kg., fixed cement concrete
in cement concrete 1:2:4
1:2:4 (1
(1
cement:
cement :2 2 coarse sand:4
sand : 4 graded stone aggregate 20 mm
20 mm
nominal size) including
nominal size) centering, shuttering
including centering, shuttering all
all complete.
complete.
(Excavation, foot rests and
(Excavation, and 1212 mm
mm thick cement plaster at
the external
the external surface
surface shall
shall be
be paid for separately) :
paid forseparately):
19.9.1.1
19.9.1.1 With common
With common burnt clay F.P.S.
burnt clay F.P.S. (non
(non modular)
modular
) each 12725.00
bricks of class designation 7.5
19.9.1.2 With Sewer bricks conforming to IS:: 4885
to IS each 12600.40
19.10 Extra depth for
Extra depth for circular type manhole
circular type 0.91m internal
manhole 0.91m dia (at
internal dia (at bottom)
bottom)
0.91 m
beyond 0.91 m to 1.67 m m
19.10.1
19.10.1 With common
With common burnt
burnt clay
clay F.P.S.
F.P.S. (non
(non modular)
modular) bricks of class
bricks of class
metre 7591.80
designation 7.5
19.10.2 With Sewer bricks conforming IS IS:: 4885 metre 7448.45

SUB HEAD : 19.0 DRAINAGE 311


Code No Description Unit Rate
19.11
19.11 Constructing brick masonry circular manhole 1.22 m m internal dia
dia at bottom
and
and 0.56
0.56 mm dia
dia atat top
top in cement mortar
in cement mortar 1:4
1:4 (1
(1 cement
cement :4 coarse sand)
:4 coarse sand)
inside cement plaster 12 12 mm
mm thick with cement mortar 1:3 1:3 (1
(1 cement
cement::
3 3 coarse
coarse sand) finished witha
sand) finished with a floating
floating coat
coat of
of neat cement foundation
neat cement foundation
concrete 1:3:6 (1 (1 cement
cement::3 3 coarse sand:
sand :6 6 graded stone aggregate
40 mm
40 mm nominal
nominal size)
size) and
and making
making necessary
necessary channel
channel inin cement concrete
cement concrete
11:2:4
:2:4 (1
(1 cement:
cement :22 coarse sand ::4 4 graded stone aggregate 20 mm
20 mm
nominal
nominal size) finished witha
size) finished with a floating
floating coat
coat of
of neat
neat cement, all complete
cement, all complete asas
per standard design:
design :
19.11.1
19.11.1 1.68 mm deep with SFRC Cover and frame (heavy duty
HD-20
HD-20 grade designation) 560
grade designation) 560 mmmm internal diameter
internal diameter
conforming toto I.S. 12592, total weight ofof cover and
and frame toto
be
be not
not less than 182
less than 182 kg. fixed in
kg. fixed in cement
cement concrete
concrete 1:2:4
1:2:4 (1
(1
cement:2 sand:4
cement : 2 coarse sand : 4 graded stone aggregate 20 mm
20 mm
nominal size) including
nominal size) including centering, shuttering all
centering, shuttering all complete.
complete.
(Excavation, foot rests and
(Excavation, and 1212 mm
mm thick cement plaster at
the external
the external surface
surface shall
shall be
be paid for separately) :
paid forseparately):
19.11.1.1
19.11.1.1 With common
With common burnt
burnt clay
clay F.P.S.
F.P.S. (non
(non modular)
modular
) each 24702.75
bricks of class designation 7.5
19.11.1.2 With Sewer bricks conforming IS IS:: 4885 each 24446.70
19.12 Extra depth for
Extra depth for circular
circular type
type manhole
manhole 1.22
1.22 mm internal dia (at
internal dia (at bottom)
bottom)
m to 2.29 m
beyond 1.68 m m ::
19.12.1
19.12.1 With common
With common burnt
burnt clay
clay F.P.S.
F.P.S. (non
(non modular)
modular) bricks
bricks of class
of class
metre 9861.45
designation 7.5
19.12.2 With Sewer bricks conforming IS IS:: 4885 metre 9674.40
19.13 Constructing brick masonry circular manhole 1.52 m
Constructing m internal dia
dia at bottom
and
and 0.56
0.56 mm dia
dia at top in
at top cement mortar
in cement mortar11:4
:4 (1
(1 cement
cement:4 : 4 coarse
coarse sand)
sand)
inside cement plaster 12 12 mm
mm thick with cement mortar 1:3 1:3 (1
(1 cement
cement::
3 3 coarse
coarse sand) finished witha
sand) finished with a floating
floating coat of neat
coat of neat cement, foundation
cement, foundation
concrete 1:3:6 (1 (1 cement
cement::3 3 coarse sand:sand :6 6 graded stone aggregate
40 mm
40 mm nominal size) and
nominal size) and making
making necessary
necessary channel
channel in cement concrete
in cement concrete
(1 cement:
1:2:4 (1 cement :22 coarse sand ::4 4 graded stone aggregate 20 mm
20 mm
nominal size) finished
nominal size) finished witha
with a floating
floating coat
coat of
of neat
neat cement,
cement, allall complete
complete asas
per standard design:
design :
19.13.1
19.13.1 2.30 m m deep with SFRC Cover and frame (heavy duty
HD-
HD- 20 20 grade
grade designation)
designation) 560560 mmmm internal diameter
internal diameter
conforming toto I.S. 12592, total weight of of cover and
and frame toto
be
be not
not less than 182
less than 182 kg. fixed in
kg. fixed cement concrete
in cement concrete 1:2:4
1:2:4 (1
(1
cement:
cement :2 2 coarse sand:4
sand : 4 graded stone aggregate 20 20 mm
mm
nominal size) including
nominal size) including centering, shuttering all
centering, shuttering all complete.
complete.
(Excavation, foot rests and
(Excavation, 12 mm
and 12 mm thick cement plaster at
the external
the external surface
surface shall
shall be
be paid for separately) :
paid forseparately):
19.13.1.1
19.13.1.1 With common
With common burnt clay F.P.S.
burnt clay F.P.S. (non
(non modular)
modular
' each 52969.10
bricks of class designation 7.5
19.13.1.2 With Sewer bricks conforming IS IS:: 4885 each 52266.80
19.14 Extra depth for
Extra depth for circular
circular type
type manhole
manhole 1.521.52 mm internal dia (at
internal dia (at bottom)
bottom)
beyond 2.30 m
m ::
19.14.1
19.14.1 With common
With common burnt
burnt clay
clay F.P.S.
F.P.S. (non
(non modular)
modular) bricks of class
bricks of class
metre 22771.85
designation 7.5
19.14.2 With Sewer bricks conforming IS IS:: 4885 metre 22288.10

312
312 SUB HEAD : 19.0 DRAINAGE
Code No Description Unit Rate
19.15 Providing
Providing M.S. foot rests
M.S. foot rests including fixing in
including fixing in manholes with 20x20x10
manholes with 20x20x10 cm
cm
blocks11:3:6
cement concrete blocks :3:6 (1
(1 cement
cement:3: 3 coarse sand
sand:6: 6 graded stone
aggregate 20 mm
aggregate 20 mm nominal size) as
nominal size) as per standard design:
per standard design :
19.15.1
19.15.1 With 20x20 mm
mm square bar each 544.70
19.15.2 With 20 mm diameter round bar
20 mm each 496.50
19.16 Providing orange colour safety foot rest of minimum minimum66 mm mm thick plastic
encapsulated as per IS IS:: 10910, on on 12 mm mm diadia steel bar
bar conforming to to
IS: 1786, having minimum cross section as as 23
23 mmx25 mm mm andand over
all minimum length 263 263 mm mm andand width as 165 mm
as 165 mm with minimum 112 112
mm space between protruded legs having
mm having22 mm mm tread on on top surface
by ribbing or chequering besides necessary and
by and adequate anchoring
each 553.70
projections on on tail length on 138 mm
on 138 mm as per standard drawing and
as per and
suitable to with stand the bend test and and chemical resistance test as per
as per
specifications
specifications andand having
having manufacture’s
manufacture's permanent
permanent identification
identification mark
mark toto
be visible even
be visible after fixing,
even after fixing, including fixing in
including fixing in manholes with 30x20x15
manholes with 30x20x15 cm cm
cement concrete block block11:3:6:3:6 (1
(1 cement
cement:3 : 3 coarse sand
sand:6 : 6 graded stone
aggregate
aggregate 20 20 mmmm nominal
nominal size)size) complete
complete as as per
per design.
design.
19.17 Replacement of ofM.S.
M.S. foot rests in manholes including dismantling concrete
blocks and fixing
blocks and fixing with
with 20x20x10
20x20x10 cm cm cement
cement concrete
concrete blocks
blocks 1:3:6
1:3:6 (1(1
cement
cement:3: 3 coarse sand : 6 graded
coarse sand:6 graded stone
stone aggregate
aggregate 20 20 mm
mm nominal size):
nominal size):
19.17.1
19.17.1 With 20x20 mm mm square bar each 670.20
19.17.2 With 20 mm diameter round bar
20 mm each 621.95
19.18 Supplying
Supplying and fixing C.I.
and fixing C.I. cover without frame
cover without frame formanholes:
for manholes :
19.18.1
19.18.1 455x610 mm
455x610 mm rectangular
rectangular C.I.C.I. cover
cover (light duty) the
(light duty) the weight
weight ofof
each 1358.00
the cover to not less than 23
to be not 23 kg
19.18.2 500 mm
500 diameter C.I.
mm diameter C.I. cover
cover (medium
(medium duty) the weight
duty) the weight of the
ofthe
each 3441.20
cover to to be notnot less than 58 58 kg
19.18.3 560
560 mm diameter C.I.
mm diameter C.I. cover
cover (heavy
(heavy duty) the weight
duty) the weight ofof the
the
each 7575.40
cover to to be notnot less than 108 108 kg
19.19 Providing and fixing
Providing and fixing inin position
position pre-cast
pre-cast R.C.C.
R.C.C. manhole cover and
manhole cover and frame
frame
of required shape and approved quality
of
19.19.1
19.19.1 LL D-D- 2.5
19.19.1.1
19.19.1.1 Rectangular shape 600x450 mm mm internal
each 1437.65
dimensions
19.19.1.2 Square shape 450 mm mm internal dimensions each 1155.45
19.19.1.3 Circular shape 450 mm mm internal diameter each 1169.65
19.19.2 MMDD - 10 10
19.19.2.1
19.19.2.1 Square shape 450 mm mm internal dimension each 1386.55
19.19.2.2 Circular shape 500 mm mm internal diameter each 1172.60
19.19.3 HHDD - 20 20
19.19.3.1
19.19.3.1 mm internal diameter
Circular shape 560 mm each 1675.70
19.19.4 EHD - 35
EHD 35
19.19.4.1
19.19.4.1 Circular shape 560 mm
mm internal dia
dia each 2123.80
19.20 Supplying
Supplying and fixing C.I.
and fixing C.I. cover 300x300 mm
cover 300x300 without frame
mm without frame forgully
for gully trap
trap
each 787.00
(standard
(standard pattern) the weight
pattern) the weight of
of cover
cover to
to be
be not
not less than 4.5
less than 4.5 kg
kg

SUB HEAD : 19.0 DRAINAGE 313


Code No Description Unit Rate
19.21
19.21 Making connection ofof drain or sewer line with existing manhole including
breaking
breaking into
into and
and making
making good the walls,
good the walls, floors
floors with
with cement
cement concrete
concrete
11:2:4
:2:4 mix
mix (1
(1 cement
cement:2
: 2 coarse sand:4
sand : 4 graded stone aggregate 20 mm
20 mm
nominal size) cement
nominal size) cement plastered
plastered onon both
both sides with cement
sides with cement mortar
mortar 1:3
1:3 (1
(1
cement
cement::3 3 coarse sand), finished
coarse sand), finished witha
with a floating
floating coat
coat of
of neat cement and
neat cement and
making necessary channels forthe
for the drain etc. complete:
complete :
19.21.1
19.21.1 For pipes 100
For 100 to 250 mm diameter
250 mm each 810.45
19.21.2 For pipes 250
250 to 300 mm diameter
300 mm each 922.40
19.21.3 For pipes 350
350 to 450 mm diameter
450 mm each 1328.45
19.22 Providing sand cast iron drop connection externally for 60 60 cm cm drop
from branch sewer line to main sewer manhole including inspection
and cleaning eye
and eye with chain and
and lid, sand cast iron drop pipe and and bend
encased
encased all-round with cement
all-round with cement concrete
concrete 1:5:10
1:5:10 (1 cement : 5 fine
(1 cement:5 fine sand
sand::
10 graded stone
10 graded stone aggregate
aggregate 4040 mm
mm nominal
nominal size) with all
size) with all centering
centering andand
shuttering required, cutting holes in walls and and making good with brick
work in
work cement mortar
in cement mortar 1:4
1:4 (1 cement :4 4 coarse
(1 cement: coarse sand)
sand) plastered with
plastered with
cement
cement mortar
mortar 1:3
1:3 (1
(1 cement
cement:3: 3 coarse sand) on
coarse sand) on inside of the
inside of the manhole
manhole
wall, lead
wall, lead caulked joints between
caulked joints between sand cast iron
sand cast iron pipes and fittings,
pipes and fittings, stiff
stiff
cement
cement mortar
mortar 1:1
1:1 (1 cement : 1 fine
(1 cement:1 fine sand) joints between
sand) joints sand cast
between sand cast iron
iron
tee
tee and
and S.W. pipe, making required channels complete as per standard
design and specifications:
design and specifications :
19.22.1
19.22.1 100 mm
100 mm dia sand cast iron drop connection each 12172.05
19.22.2 150 mm
150 mm dia sand cast iron drop connection each 16577.80
19.23 Extra fordepths
for depths beyond 60 cm
cm ofsand
of sand cast iron drop connection complete:
19.23.1
19.23.1 For 100
For 100 mm
mm dia sand cast iron drop connection
connection metre 3240.45
19.23.2 150 mm
For 150 mm dia sand cast iron drop connection
connection metre 4126.90
19.24 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame,
including stacking of useful materials near the
the site and
and disposal of
unserviceable materials within 50 m lead as
50 m as per direction of Engineer-in-
charge:
19.24.1
19.24.1 Rectangular manhole 90x80 cm
cm and 45 cm
cm deep each 2540.85
19.24.2 Rectangular manhole 120x90 cm cm deep
cm and 90 cm each 4475.50
19.24.3 Rectangular arch type manhole 140x90 cm cm and 2.45 mm
each 8466.35
deep
19.24.4 Circular manhole 122 cmcm diameter and m deep
and 1.68 m each 6472.40
19.25 Extra for
for depth of
of manholes dismantled:
dismantled :
19.25.1
19.25.1 Rectangular manhole 90x80 cm cm and beyond 45 cm
cm depth metre 2045.50
19.25.2 Rectangular manhole 120x90 cm cm depth
cm and beyond 90 cm metre 2436.90
19.25.3 Rectangular arch type manhole 140x90 cm cm and beyond
metre 1975.85
2.45 m
2.45 depth (up
m depth to 4.25 m
(up to4.25 depth)
m depth)
19.25.4 Circular manhole 122 cm cm diameter and
and beyond 1.68 mm
metre 2229.20
depth (up
depth to 2.29
(up to 2.29 m depth)
m depth)
19.26 Raising manhole cover and and frame slab to required level including
dismantling existing slab and
and making good the the damage as as required
(Raising depth of
(Raising depth of manhole to be paid
manhole tobe paid separately)
separately)::
19.26.1
19.26.1 Rectangular manhole 90x80 cm cm with rectangular cover 600
600
each 2625.50
xx 450 mm of
450 mm of grade LD
LD - 2.5
2.5
19.26.2 Rectangular manhole 120x90 cm cm with circular cover 500
500
each 4168.05
mm dia
mm dia of
of grade MD
MD - 10
10

314
314 SUB HEAD : 19.0 DRAINAGE
Code No Description Unit Rate
19.26.3 cm with circular cover 560
Rectangular manhole 120x90 cm 560
each 3881.50
mm dia
mm dia of
of grade HD
HD - 20
20
19.26.4 Circular manhole 140 cmcm diawith
dia with circular cover 600
600 mm
mm dia
dia
each 320.15
of
of grade EHD
EHD - 35
35
19.27 Constructing brick masonry road gully chamber 50x45x60 cm cm with bricks
in cement mortar
in cement mortar 1:4
1:4 (1
(1 cement
cement::4 4 coarse
coarse sand)
sand) including
including 500x450
500x450 mm
mm
pre-cast R.C.C. horizontal grating with frame complete as per standard
design::
design
19.27.1
19.27.1 With common
With common burnt
burnt clay
clay F.P.S.
F.P.S. (non
(non modular)
modular) bricks
bricks of
of class
class
each 5957.90
designation 7.5
19.28 Constructing brick masonry road gully chamber 45x45x77.5 cm cm with
bricks
bricks in cement mortar
in cement mortar11:4 :4 (1 cement : 4 coarse
(1 cement:4 sand ) with
coarse sand) with precast
precast
R.C.C. vertical grating complete as per standard design: design :
19.28.1
19.28.1 With common
With common burnt
burnt clay
clay F.P.S.
F.P.S. (non
(non modular)
modular) bricks
bricks of class
of class
each 6889.80
designation 7.5
19.29 Constructing brick masonry road gully chamber 110x50x77.5 cm cm with
bricks
bricks in cement mortar
in cement mortar11:4:4 (1
(1 cement
cement:4 : 4 coarse
coarse sand)
sand) including
including 500x450
500x450
mm precast R.C.C. horizontal grating with frame and
mm and vertical grating
complete as per standard design:design :
19.29.1
19.29.1 With common
With common burnt
burnt clay
clay F.P.S.
F.P.S. (non
(non modular)
modular) bricks
bricks of class
of class
each 11520.55
designation 7.5
19.30 Constructing brick masonry chamber forunderground
Constructing for underground C.I. inspection
chamber and bends with bricks in cement mortar mortar11:4 :4 (1
(1 cement
cement:4 : 4 coarse
sand) C.I. cover
sand) C.I. with frame
cover with frame (light duty) 455x610
(light duty) 455x610 mm mm internal
internal dimensions,
dimensions,
total weight of
of cover with frame to not less than 38
to be not 38 kg (weight of cover
23
23 kg and weight
kg and weight ofof frame
frame 1515 kg),
kg), R.C.C.
R.C.C. top top slab with 1:1.5:3
slab with 1:1.5:3 mix
mix (1
(1
cement
cement:: 1.5 fine sand:
1.5fine sand :3 3 graded
graded stone
stone aggregate
aggregate 20 20 mm
mm nominal size),
nominal size),
foundation concrete
foundation concrete 1:5:10
1:5:10 (1(1 cement
cement::55 fine fine sand
sand:: 10 graded stone
10 graded stone
aggregate
aggregate 40 40 mmmm nominal size), inside
nominal size), inside plastering
plastering 12 12 mm thick with
mm thick with
cement
cement mortar
mortar 1:31:3 (1
(1 cement
cement:3 : 3 coarse sand), finished
coarse sand), finished smooth with a
smooth witha
floating coat
floating of neat
coat of neat cement
cement on walls and
on walls and bed concrete etc.
bed concrete etc. complete
complete as as
per standard design:
19.30.1
19.30.1 Inside dimensions 455x610 mm
mm and 45 cm
cm deep forsingle
for single
line::
pipe line
19.30.1.1
19.30.1.1 With common
With common burnt clay F.P.S.
burnt clay F.P.S. (non
(non modular)
modular
) each 6937.90
bricks of class designation 7.5
19.30.2 Inside dimensions 500x700 mm mm and 45 cm cm deep forpipe
for pipe
line with one
one or two inlets::
two inlets
19.30.2.1
19.30.2.1 With common
With common burnt clay F.P.S.
burnt clay F.P.S. (non
(non modular)
modular
) each 8150.50
bricks of class designation 7.5
19.30.3 Inside dimensions 600x 850 mm mm and 45 cmcm deep forpipe
for pipe
line with three or more inlets
inlets::
19.30.3.1
19.30.3.1 With common
With common burnt clay F.P.S.
burnt clay F.P.S. (non
(non modular)
modular
) each 9594.35
bricks of class designation 7.5
19.31
19.31 Extra for
for depth beyond 45 cm
cm ofbrick chamber::
of brick masonry chamber
19.31.1
19.31.1 For 455x610 mm
For mm size
19.31.1.1
19.31.1.1 With common
With common burnt clay F.P.S.
burnt clay F.P.S. (non
(non modular)
modular)
metre 6117.00
bricks of class designation 7.5
19.31.2 mm size
For 500x700 mm

SUB HEAD : 19.0 DRAINAGE 315


Code No Description Unit Rate
19.31.2.1
19.31.2.1 With common
With common burnt
burnt clay
clay F.P.S.
F.P.S. (non
(non modular)
modular)
metre 6680.60
bricks of class designation 7.5
19.31.3 For 600x850 mm
mm size
19.31.3.1
19.31.3.1 With common
With common burnt
burnt clay
clay F.P.S.
F.P.S. (non
(non modular)
modular
) metre 7789.85
bricks of class designation 7.5
19.32 Making soak pit 2.5 m diameter 3.0 metre deep with 45x
2.5 m 45 x 45
45 cm
cm dry brick
honey comb shaft with bricks and
and S.W. drain pipe 100
100 mm
mm diameter,
diameter, 1.8
m long complete as per standard design.
m
19.32.1
19.32.1 With common
With common burnt
burnt clay
clay F.P.S.
F.P.S. (non
(non modular)
modular) bricks
bricks of class
of class
each 26861.90
designation 7.5
19.33 Constructing soak pit
Constructing soak pit 1.20x1.20x1.20
1.20x1.20x1.20 m filled with
m filled with brick
brick bats
bats including
including
S.W. drain pipe 100
100 mm
mm diameter and
and 1.20 m m long complete as per each 2890.10
standard design.
19.34 Providing
Providing and fixing S.W.
and fixing S.W. intercepting trap in
intercepting trap in manholes with stiff
manholes with stiff mixture
mixture
of
of cement
cement mortar
mortar11:1:1 (1
(1 cement
cement::11 fine
fine sand)
sand) including testing of
including testing joints
of joints
complete::
etc. complete
19.34.1
19.34.1 100 mm
100 mm dia each 441.40
19.34.2 150 mm
150 mm dia each 602.65
19.35 Providing and laying
Providing and laying Non
Non Pressure
Pressure NP-3 class (Medium
NP-3 class duty) R.C.C.
(Medium duty) R.C.C.
pipes
pipes including
including collars/spigot jointed with
collars/spigot jointed with stiff
stiff mixture
mixture of
of cement
cement mortar
mortar
in the proportion
in the of 1:2
proportion of 1:2 (1 cement :2 2 fine
(1 cement: fine sand)
sand) including testing of
including testing of joints
joints
etc. complete
19.35.1
19.35.1 450 mm dia RCC
450 mm RCC pipes. metre 2676.55
19.35.2 600 mm
600 mm dia RCC pipes.
RCC metre 3401.25
19.35.3 900 mm dia RCC
900 mm RCC pipes. metre 5377.25
19.35.4 mm dia
1000 mm RCC pipes. (Laying by
dia RCC by manual/ machanical
metre 6656.55
means)
means)
19.35.5 mm dia
1200 mm RCC pipes. (Laying by
dia RCC by manual/ machanical
metre 9126.20
means)
means)
19.35.6 mm dia
1800 mm RCC pipes. (Laying by
dia RCC by manual/ machenical
metre 16184.00
means)
means)
19.36 Providing
Providing and
and laying
laying Non
Non Pressure
Pressure NP-4 class (Heavy
NP-4 class (Heavy duty)
duty) R.C.C.
R.C.C. pipes
pipes
including
including collars/spigot jointed with
collars/spigot jointed with stiff
stiff mixture of cement
mixture of cement mortar
mortar in the
in the
proportion of 1:2
proportion of 1:2 (1
(1 cement
cement::2 2 fine
fine sand)
sand) including testing of
including testing joints etc.
of joints etc.
complete
19.36.1
19.36.1 450 mm dia RCC
450 mm RCC pipes. metre 3053.55
19.36.2 600 mm dia RCC
600 mm RCC pipes. metre 3934.75
19.36.3 900 mm dia RCC
900 mm RCC pipes. metre 7397.40
19.36.4 mm dia
1000 mm RCC pipes. (Laying by
dia RCC by manual/ machanical
metre 9181.75
means)
means)
19.36.5 mm dia
1200 mm RCC pipes. (Laying by
dia RCC by manual/ machanical
metre 11119.35
means)
means)
19.36.6 mm dia
1800 mm RCC pipes. (Laying by
dia RCC by manual/ machanical
metre 22578.75
means)
means)

316
316 SUB HEAD : 19.0 DRAINAGE
SUB HEAD
SUB HEAD:: 20.0
PILE WORK
20.0 PILE WORK

Code No Description Unit Rate


20.1
20.1 Providing, driving with hydraulic piling rigs with power units and
Providing, and installing
driven cast-in-situ reinforced cement concrete piles of grade M-25 of of
specified diameter and
specified diameter and length
length below the pile
below the pile cap,
cap, toto carry safe working
carry safe working
load
load not
not less than specified,
less than specified, excluding the cost
excluding the of steel
cost of steel reinforcement
reinforcement but
but
including the
the cost of shoe and thelength
the length of pile to be
be embedded in thethe pile
cap etc. all complete. (Length of pile for payment shall be
cap be measured from
top of
top shoe tothebottom
ofshoe to the bottom of
of pile cap) :
pile cap):
20.1.1
20.1.1 400 mm dia piles
400 mm metre 2767.00
20.1.2 450 mm dia piles
450 mm metre 3430.65
20.1.3 500 mm
500 mm dia piles metre 4129.95
20.1.4 550 mm
550 mm dia piles metre 4530.90
20.1.5 750 mm
750 mm dia piles metre 7738.55
20.1.6 mm dia
1000 mm diapiles
piles metre 12748.45
20.1.7 mm dia
1200 mm diapiles
piles metre 16671.05
20.1.8 1500 mmmm dia
diapiles
piles metre 23577.75
20.2 Boring, providing and installation bored cast-in-situ
and installation cast-in-situ reinforced cement
concrete
concrete piles
piles ofof grade
grade M-25
M-25 of specified diameter
ofspecified diameter andand length
length below the
below the
pile cap, to
pile cap, to carry
carryaa safe
safe working
working load
load not
not less than specified,
less than specified, excluding
excluding thethe
cost of steel reinforcement but including the the cost of boring with bentonite
solution and
and temporary casing of of appropriate length for for setting out
out and
and
removal of of same and and thelength
the length of the pile to be embedded in the
to be the pile
cap
cap etc.
etc. by
by percussion drilling using
percussion drilling using Direct
Direct mud circulation (DMC)
mud circulation (DMC) or or
and chisel technique by tripod and
Bailer and and mechanical Winch Machine all
complete, including removal of of excavated earth with all its lifts andand leads
(length
(length of
of pile for payment
pile for shall be
payment shall be measured
measured up to bottom of
up tobottom of pile cap).
pile cap).
20.2.1
20.2.1 450 mm dia piles
450 mm metre 2278.30
20.2.2 500 mm
500 mm dia piles metre 2703.25
20.2.3 600 mm
600 mm dia piles metre 3637.20
20.2.4 750 mm
750 mm dia piles metre 5581.20
20.2A Boring, providing and installation bored cast-in-situ
and installation cast-in-situ reinforced cement
concrete
concrete piles of garde
piles of garde M-25
M-25 of specified diameter
ofspecified diameter and and length
length below
below pile
pile
cap, to carrya
cap, to carry a safe
safe working
working load
load not
not less than specified,
less than specified, excluding
excluding thethe
cost of steel reinforcement but including the the cost of boring with bentonite
solution and
and temporary casing of of appropriate length forfor setting out
out and
and
removal ofof same and and thelength
the length of the pile to be embedded in the
to be the pile
cap etc. by
cap by Crawler mounted, telescopic boom hydraulic pilling Rig Rig all
complete, including removal of of excavated earth with all its lifts and
and leads
(length
(length of
of pile for payment
pile for shall be
payment shall be measured
measured up to bottom of
up tobottom of pile cap).
pile cap). metre
Note: Truck Mounted rotary/TMR/Tube well boring machine shall not
not be
be
used.
20.2A.1
20.2A.1 600 mm
600 mm dia piles metre 5386.25
20.2A.2 750 mm
750 mm dia
dia piles metre 7758.75
20.2A.3 mm dia
1000 mm diapiles
piles metre 12990.80
20.2A.4 mm dia
1200 mm diapiles
piles metre 17025.75
20.2A.5 mm dia
1500 mm diapiles
piles metre 24408.80

SUB HEAD:: 20.0 PILE WORK


SUB WORK 319
Code No Description Unit Rate
20.3 Boring with hydraulic piling rigs with power units, providing and and installing
cast
cast in situ single
in situ single under
under reamed
reamed piles of specified
piles of diameter and
specified diameter and length
length
below pile cap concrete, to carrya
cap in M-25 cement concrete, carry a safe working load not
less than specified,
less than excluding the
specified, excluding the cost
cost of
of steel
steel reinforcement
reinforcement butbut including
including
the
the cost of boring with bentonite solution and and the
the length of the pile to be
to be
embedded in pile cap cap etc. all complete. (Length of of pile for payment shall
be
be measured
measured upto to the
upto to the bottom
bottom of
of pile
pile cap)
cap)::
20.3.1
20.3.1 300 mm
300 mm dia piles metre 3065.60
20.3.2 400 mm dia piles
400 mm metre 3797.30
20.3.3 450 mm dia piles
450 mm metre 4232.75
20.3.4 550 mm
550 mm dia piles metre 4721.15
20.4 Extra over single under ream forproviding additional bulbs in under
for providing additional
reamed
reamed piles,
piles, under specified diameter(only
under specified diameter(only the
the nos.
nos. of extra bulbs
of extra are
bulbs are
to be
to be paid)
paid)
20.4.1
20.4.1 300 mm
300 mm dia piles each 2626.30
20.4.2 400 mm dia piles
400 mm each 2924.45
20.4.3 450 mm dia piles
450 mm each 3104.20
20.4.4 550 mm
550 mm dia piles each 3360.15
20.5 Providing, driving (with vibrating pile driving hammer complete with power
Providing,
units
units&& accessories)
accessories) andand installing driven Pre-cast
installing driven Pre-cast reinforced
reinforced cement
cement
concrete
concrete piles of specified
piles of specified diameter
diameter and
and length
length below the pile
below the pile cap
cap in
in M-25
M-25
cement
cement concrete
concrete toto carry safe working
carry safe working load
load not
not less than specified
less than specified with
with
aa central through preformed hole with M.S. black pipe of dia, 40 mm for
40 mm
grouting with
grouting with cement sand grouting
cement sand of mix
grouting of mix 1:2
1:2 (1cement
(1 cement::2 2 coarse
coarse sand)
sand)
under
under sufficient
sufficient positive
positive pressure
pressure toto ensure
ensure complete filling including
complete filling including
centring, shuttering, driving and
centring, and removing the steel casing pipe and and
lifting casing etc. complete butbut excluding the cost of steel reinforcement.
(Length of pile for payment shall be be measured from top oftheof the shoe tothe
to the
bottom
bottom of of pile cap).
pile cap).
20.5.1
20.5.1 400
400 mmmm dia piles metre 3727.80
20.5.2 450 mm dia piles
450 mm metre 4766.25
20.5.3 500 mm
500 mm dia piles metre 4931.35
20.5.4 550 mm
550 mm dia piles metre 5633.00
20.5.5 750 mm
750 mm dia piles metre 10846.80
20.5.6 1000 mm mm diapiles
dia piles metre 14946.40
20.6 Vertical load
Vertical testing of
load testing of piles
piles in accordance with
in accordance with IS 2911 (Part
IS 2911 (Part IV)
IV) including
including
installation of loading platform by
installation by Kentledge/Anchor piles method and
preparation of pile head or or construction of test cap
cap and
and dismantling of
test cap
test after test
cap after test etc. complete as
etc. complete as per
per specification
specification&& the
the direction
direction ofof
Engineer in-charge.
Note: 1. Initial and
and Routine Load Test shall notnot be
be carried out by Dynamic
out by
method oftesting.
of testing.
Note: 2. Testing agency shall submit the design of of loading platform forthe
for the
approval of Engineer-in-charge.
20.6.1
20.6.1 50 tonne Safe capacity
Single pile upto 50
20.6.1.1
20.6.1.1 Initial test (Test
Initial test (Test Load 2.5 times the
Load 2.5times the Safe
Safe capacity)
capacity) per test 54771.50
20.6.1.2 Routine test (Test Load 1.5
1.5 times the Safe
capacity)
capacity) per test
per 19632.40

320
320 SUB HEAD:: 20.0 PILE
SUB PIi.E WORK
WORK
Code No Description Unit Rate
20.6.2 Single pile above 50 tonne and 100 tonne Safe capacity
and upto 100
20.6.2.1
20.6.2.1 Initial test (Test
Initial test (Test Load 2.5 times the
Load 2.5times the Safe capacity)
Safe capacity) pertest
per test 61173.35
20.6.2.2 Routine test (Test Load 1.5
1.5 times the Safe
capacity)
capacity) per test
per 32436.10
20.6.3 oftwo
Group of two ormore 50 tonne Safe capacity
or more piles upto 50
20.6.3.1
20.6.3.1 Initial test (Test
Initial test (Test Load 2.5 times the
Load 2.5times the Safe capacity)
Safe capacity) per test
per 70420.50
20.6.3.2 Routine test (Test Load 1.5
1.5 times the Safe
capacity)
capacity) per test
per 40545.15
20.7 Cyclic vertical load testing of pile in accordance with IS Code ofpractice
of practice
IS:2911
IS:2911 (part
(part IV)
IV) by
by Kentledge
Kentledge method
method including
including preparation of pile
preparation of pile head
head
etcfor.
etc for.
20.7.1
20.7.1 Single pile
20.7.1.1
20.7.1.1 Upto 50 tonne
Upto 50 tonne Safe
Safe capacity
capacity pile
pile per test
per 19632.40
20.7.1.2 Above 50 tonne and and upto 100 100 tonne Safe
capacity pile per test 32436.10
20.7.2 Group ofoftwo
two ormore
or more piles
20.7.2.1
20.7.2.1 Upto 400 tonne
Upto 400 tonne Safe
Safe capacity
capacity of group
of group per test
per 40545.15
20.8 Lateral load testing of single pile in accordance with IS
IS:: Code ofofpractice
practice
IS: 2911 (Part
IS: 2911 (Part IV) for determining
IV) for determining safe allowable lateral
safe allowable lateral load
load on
on pile
pile::
20.8.1
20.8.1 Upto
Upto 50 tonne capacity
50 tonne capacity pile
pile per test
per 19632.40
20.8.2 Above 50 tonne and 100 tonne capacity pile
and upto 100 per test 32862.90
20.9 Integrity testing of Pile using Low
Low Strain/ Sonic Integrity Test/ Sonic Echo
Test method in accordance with IS :14893 including surface preparation
of pile top by removing soil, mud, dust&
top by dust & chipping lean concrete lumps
etc. and use of computerised equipment and
and use and high skill trained personal for
for
conducting the test&
test & submission of
of results, all complete as per direction
of Engineer-in-charge. per test
per 1153.20
Note :- The
The inclusion of the
the above item in the
the schedule ofof work shall be
be
judiciously decided by the technical sanctioning authority,
authority, keeping in view
the
the quality control,
control, type of
of soil strata&
strata & importance of
of the project.

SUB HEAD:: 20.0 PILE WORK


SUB WORK 321
321
SUB HEAD
SUB HEAD:: 21.0
ALUMINIUM WORK
21.0 ALUMINIUM WORK
WORK

Code No Description Unit Rate


21.1
21.1 Providing and fixing
Providing and fixing aluminium
aluminium work
work fordoors,
for doors, windows,
windows, ventilators
ventilators and
and
partitions with extruded
partitions with extruded built
built up standard tubular
up standard tubular sections/
sections/ appropriate
appropriateZZ
sections and
and other sections of approved make conforming to 733 and
to IS: 733 and
IS:
IS: 1285, fixing with
1285, fixing with dash fasteners of
dash fasteners of required
required diadia and size, including
and size, including
necessary filling up
necessary filling the gaps
up the gaps atjunctions,
at junctions, i.e.
i.e. at top, bottom
at top, and sides
bottom and sides
with required EPDM rubber/ neoprene gasket etc. Aluminium sections
be smooth, rust free, straight, mitred and
shall be and jointed mechanically
wherever required including cleat angle, Aluminium snap beading for for
glazing/ / panelling,
glazing panelling, C.P. brass// stainless steel screws, all complete as per
architectural drawings and
architectural and the directions of Engineer-in-charge. (Glazing,
(Glazing,
paneling and dash
paneling and dash fasteners
fasteners to to be
be paid for separately) :
paid forseparately):
21.1.1
21.1.1 For fixed portion
For fixed portion
21.1.1.1
21.1.1.1 Anodised aluminium (anodised transparent or
dyed torequired
to required shade according to IS: 1868,
Minimum anodic coating
Minimum anodic of grade
coating of grade ACAC 15)
15) kg 495.05
21.1.1.2 Powder coated aluminium (minimum
thickness of
thickness of powder
powder coating
coating 5050 micron)
micron) kg 530.90
21.1.1.3 Polyester powder coated aluminium (minimum
thickness of polyester powder coating 50 50
micron)
micron) kg 539.85
21.1.2 For shutters of doors, windows && ventilators including
providing
providing and fixing hinges/
and fixing hinges/ pivots
pivots and
and making
making provision
provision
for fixing
for fixing ofof fittings
fittings wherever
wherever required
required including
including thethe cost of
cost of
EPDM rubberrubber// neoprene gasket required (Fittings shall be be
paid for separately)
paid forseparately)
21.1.2.1
21.1.2.1 Anodised aluminium (anodised transparent or
dyed torequired
to required shade according to IS: 1868,
Minimum anodic coating
Minimum anodic of grade
coating of grade ACAC 15)
15) kg 598.60
21.1.2.2 Powder coated aluminium (minimum
thickness of
thickness of powder
powder coating
coating 5050 micron)
micron) kg 634.45
21.1.2.3 Polyester powder coated aluminium (minimum
thickness of polyester powder coating 50 50
micron)
micron) kg 643.45
21.2 Providing
Providing andand fixing
fixing 12 12 mm thick prelaminated
mm thick prelaminated particle
particle board flat pressed
board flat pressed
three layer or graded wood particle board conforming to to IS: 12823 Grade
I l Type
Type ll,
II, in
in panelling fixed in
panelling fixed aluminum doors,
in aluminum doors, windows
windows shutters and
shutters and
partition frames with C.P. brass brass// stainless steel screws etc. complete as
per architectural
architectural drawings and and directions of engineer-in-charge.
21.2.1
21.2.1 Pre-laminated particle board with decorative lamination on on
one
one side and and balancing lamination on on other side sqm
sqm 1139.30
21.2.2 Pre-laminated particle board with decorative lamination on on
both sides sqm
sqm 1115.40
21.3 Providing
Providing andand fixing
fixing glazing
glazing in aluminium door,
in aluminium door, window,
window, ventilator
ventilator shutters
shutters
and partitions etc. with EPDM rubber// neoprene gasket etc. complete as
and
per the architectural
architectural drawings and and the directions of engineer-in-charge
engineer-in-charge..
(Cost of aluminium
(Cost of aluminium snapsnap beading shall be
beading shall be paid
paid in
in basic
basic item):
item):
21.3.1
21.3.1 With float
With float glass
glass panes of 4.0 mm thickness
panes of4.0mm thickness (weight
(weight not
not less
less
than 10kg/sqm)
than 10kg/sqm) sqm
sqm 1176.80

SUB HEAD:: 21.0 ALUMINIUM WORK


SUB WORK 325
325
Code No Description Unit Rate
21.3.2 With float
With float glass
glass panes of55 mm
panes of thickness (weight
mm thickness (weight not
not less
less
than 12.50
than 12.50 kg/sqm)
kg/sqm) sqm
sqm 1505.25
21.3.3 With float
With float glass
glass panes
panes ofof88 mm thickness (weight
mm thickness (weight not
not less
less
than 20
than 20 kg/sqm)
kg/sqm) sqm
sqm 1685.40
21.4 Providing and fixing
Providing and fixing double
double action
action hydraulic floor spring
hydraulic floor spring of
of approved
approved brand
brand
and manufacture conforming to
and IS:: 6315, having brand logo embossed
to IS
on thebody/
the body / plate with double spring mechanism and door weight upto
125
125 kg, for doors,
kg, for doors, including cost of
including cost cutting floors,
of cutting floors, embedding
embedding in floors
in floors
as
as required
required and
and making good the
making good the same
same matching
matching to to the
the existing
existing floor
floor
finishing and
finishing and cover
cover plates with brass
plates with brass pivot
pivot and single piece
and single piece M.S. sheet
M.S. sheet
box with slide plate etc. complete as per the direction of Engineer-
outer box
in-charge.
in-charge.
21.4.1
21.4.1 With stainless steel cover plate minimum 1.25 mm mm thickness each 2823.85
21.4.2 With brass cover plate minimum 1.25 mm mm thickness each 2966.10
21.5 Providing and fixing
Providing and fixing powder
powder coated
coated aluminium
aluminium work work (minimum thickness
(minimum thickness
of
of powder
powder coating
coating 50 50 micron)
micron) consisting
consisting of of tee/
tee/ angle
angle sections,
sections, of of
approved make conforming to IS:: 733
to IS 733 in frames offalse
of false ceiling including
aluminium angle cleats with necessary C.P. brass/ stainless steel sunk
screws,
screws, aluminium
aluminium perimeter angles fixed
perimeter angles fixed to
to wall
wall with
with stainless
stainless steel
steel rawl
rawl
plugs
plugs@@ 450450 mm
mm centre to centre
centre to centre and fixing the
and fixing the frame
frame work
work toG.I.
to G.I. level
level
hangers66 mm
adjusting hangers mm dia. with necessary cadmium plated machine
screws all complete as per approved architectural
architectural drawings and and direction
of the
the Engineer-in-charge (level adjusting hangers, ceiling cleats and and
expansion
expansion hold fasteners to
hold fasteners to be
be paid for separately).
paid forseparately). kg 817.15
21.6 Providing
Providing and fixing 6 mm
and fixing6 dia. G.I.
mm dia. G.I. level adjusting hangers
level adjusting hangers (upto
(upto 1200
1200 mm
mm
length), fixed to
length), fixed to roof
roof slabs
slabs by
by means
means of ceiling cleats
ofceiling cleats made out of G.I. flat
made outofG.I. flat
40x3 mm
mm size 60 mm long and
60 mm and stainless steel expandable dash fastener
mm dia and
of 12.5 mm and 50 mm long, complete as per direction of Engineer-
50 mm
in-charge.
in-charge. each 82.45
21.7 Providing
Providing and fixing machine
and fixing machine moulded aluminium covering
moulded aluminium of approved
covering of approved
pattern&& design, made out
pattern out ofmachine cutaluminium
of machine cut aluminium sheet and
and machine
holed for
for receiving dash fastener,
fastener, over expansion joints on on vertical
surfaces/ceiling floors, the
surfaces/ceiling floors, the fixing
fixing on
on plate
plate in one row
in one row on
on one
one side
side of joint
of joint
only shall be
be done with stainless steel dash fasteners of of88 mm
mm dia and and
75 mm
75 mm long bolt including providing aluminium washers2 mm thick&
washers 2 mm 15
thick & 15
mm dia
mm dia,, ata
at a staggered pitch of 200
200 mm
mm centre to centre including drilling
holes in the
the receiving surface and
and providing expandable plastic sleeves in
holes etc. complete as perper direction of Engineer-in-charge.
21.7.1
21.7.1 Anodised aluminium sheet 2.5 mm mm thick (anodised
transparent or dyed to to required shade according to IS:
1868,
1868, Minimum
Minimum anodic coating of
anodic coating of grade AC 15)
grade AC 15) kg 680.55
21.7.2 Powder coated aluminium sheet 2.5 mm mm thick (minimum
thickness of
thickness of powder
powder coating
coating 50
50 micron)
micron) kg 716.40
21.8 Filling the
the gap
gap in between aluminium frame&
frame & adjacent RCC/ Brick/ Stone
work by providing weather silicon sealant over backer rod of of approved
as per
quality as per architectural
architectural drawings and
and direction of Engineer-in-charge
complete.
21.8.1
21.8.1 Upto
Upto55 mm
mm depth
depth and
and55 mm width
mm width metre 96.75

326
326 SUB HEAD:: 21.0 ALUMINIUM WORK
SUB WORK
Code No Description Unit Rate
21.9 Extra for
for applying additional anodic coating AC
AC 25
25 instead of AC 15 to
AC 15
aluminium extruded sections.
21.9.1
21.9.1 For fixed portion
For fixed portion kg 12.80
21.9.2 For shutters of doors, windows&
windows & ventilators kg 12.80
21.10 Providing
Providing andand fixing
fixing double
double glazed
glazed hermetically
hermetically sealed glazing in
sealed glazing in
aluminium windows, ventilators and partition etc. with6
and partition mm thick clear
with 6 mm
float glass
float glass both side, having
both side, having 12 12 mm
mm air gap, including
air gap, including providing
providing EPDM
EPDM
gasket, perforated aluminium spacers, desiccants, sealant (Both primary
and
and secondary sealant) etc.
secondary sealant) as per
etc. as specifications, drawings
per specifications, drawings and direction
and direction
of Engineer-in-charge complete. sqm
sqm 4997.70
21.11
21.11 Providing
Providing andand fixing
fixing stainless
stainless steel
steel (SS
(SS 304 grade) adjustable
304 grade) adjustable friction
friction
windows stays of approved quality with necessary stainless steel screws
etc. to the
the side hung windows as per per direction of Engineer-in-charge
complete.
21.11.1
21.11.1 205
205XX 19 19 mm
mm each 344.30
21.11.2 255
255XX 19 19 mm
mm each 387.00
21.11.3 355
355XX 19 19 mm
mm each 325.80
21.11.4 510XX 19
510 19 mm
mm each 802.40
21.11.5 710
710XX 19 19 mm
mm each 1478.15
21.12 Providing
Providing and fixing aluminium
and fixing tubular handle
aluminium tubular handle bar
bar 32
32 mm outer dia,
mm outer dia, 3.0
3.0
mm thick&
mm thick & 2100 mmmm long with SS
SS screws etc
etc .complete as
as per direction
of Engineer-in-Charge.
21.12.1
21.12.1 Anodized (AC
Anodized (AC 15
15)) aluminium
aluminium tubular
tubular handle
handle bar
bar each 575.75
21.12.2 Powder coated minimum thickness 50 50 micron aluminium
tubular handle bar each 631.55
21.12.3 Polyester powder coated minimum thickness 50 50 micron
aluminium tubular handle bar each 645.50
21.13 Providing
Providing and fixing Brass
and fixing Brass 100
100 mm
mm mortice
mortice latch
latch and
and lock with 6 levers
lock with6 levers
without pair
without pair of
of handles
handles (best
(best make of approved quality)
make ofapproved for aluminium
quality) for aluminium
doors including necessary cutting and
and making good etc. complete. each 528.85
21.14 Providing
Providing and fixing anodised
and fixing aluminium (anodised
anodised aluminium transparent or
(anodised transparent or dyed
dyed toto
required shade according to IS: 1868. Minimum anodic coating of grade
AC 15)
AC sub frame
15) sub frame work
work forwindows
for windows and
and ventilators
ventilators with
with extruded
extruded built
built up
up
standard tubular sections of approved make conforming to 733 and
to IS: 733 and IS:
1285, fixed with
1285, fixed with dash
dash fastener
fastener of
of required dia and
required dia and size
size (Dash fastener to
(Dash fastener to
be
be paid for separately).
paid forseparately). kg 402.80
21.15 Providing and fixing
Providing and fixing aluminium
aluminium casement windows fastener
casement windows fastener of
of required
required
length for
for aluminium windows with necessary screws etc. complete.
21.15.1
21.15.1 Anodized (AC
Anodized (AC 15) aluminium
15)aluminium each 89.40
21.15.2 Powder coated minimum thickness 50 50 micron aluminium each 97.95
21.15.3 Polyester powder coated minimum thickness 50 50 micron
aluminium each 95.10
21.16 Providing and fixing
Providing and fixing aluminium
aluminium round shape handle
round shape of outer
handle of outer dia
dia 100
100 mm
mm
with SS
SS screws etc. complete as per direction of Engineer-in-charge
21.16.1
21.16.1 Anodized (AC
Anodized (AC 15)
15) aluminium
aluminium each 107.90
21.16.2 Powder coated minimum thickness 50
50 micron aluminium each 109.30
21.16.3 Polyester powder coated minimum thickness 50
50 micron
aluminium each 112.15

SUB HEAD:: 21.0 ALUMINIUM WORK


SUB WORK 327
327
Code No Description Unit Rate
21.17 Providing
Providing and and fixing
fixing anodised
anodised aluminium
aluminium grill
grill (anodised transparent
(anodised transparent
or dyed to to required shade according to IS: 1868 with minimum anodic
coating
coating of of grade
grade AC AC 15)
15) ofof approved
approved design/pattern,
design/pattern, with
with approved
approved
standard section and
standard section and fixed
fixed to
to the
the existing
existing window
window frame
frame with
with C.P.
C.P. brass/
brass/
stainless steel screws@
screws @ 200 200 mmmm centre to centre, including cutting the the
grill to proper
grill to proper opening
opening size for fixing
size for fixing and
and operation
operation of of handles
handles and fixing
and fixing
approved anodised aluminium standard section around the the opening, all
complete as per requirement and and direction of Engineer-in-charge. (Only
weight of
weight of grill
grill to
to be
be measured for payment).
measured forpayment). kg 638.35
21.18 Providing and fixing
Providing and fixing 12
12 mm thick frameless
mm thick frameless toughened
toughened glass
glass door
door shutter
shutter
of
of approved
approved brand
brand and
and manufacture,
manufacture, including
including providing and fixing
providing and fixing top
top& &
bottom
bottom pivot
pivot&& double
double acting
acting hydraulic floor spring
hydraulic floor spring type
type fixing
fixing arrangement
arrangement
and
and making
making necessary
necessary holes etc. for
holes etc. for fixing
fixing required door fittings,
required door fittings, all
all
per direction of Engineer-in-charge (Door handle, lock and
complete as per and
stopper
stopper etc.to
etc.to be
be paid
paid separately).
separately). sqm
sqm 5325.90
21.19 Filling the
the gap
gap in between aluminium/ stone/ wood frame and and adjacent
RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/
structural
structural non sag elastomeric
non sag elastomeric PU sealant over
PU sealant over backer
backer rod of approved
rod of approved
as per
quality as per architectural
architectural drawings and
and direction of Engineer-in-charge
complete, complying toASTM DIN 18540-F
to ASTM C920, DIN 18540-F&& ISO
ISO 11600
21.19.1
21.19.1 Upto
Upto55 mm depth and
mm depth and55 mm width
mm width metre 148.10
21.19.2 Upto
Upto 10
10 mm depth and
mm depth and 10
10 mm width
mm width metre 200.95
21.19.3 Upto 20 mm
Upto 20 depth and
mm depth 20 mm
and 20 width
mm width metre 363.20

328
328 SUB HEAD:: 21.0 ALUMINIUM WORK
SUB WORK
SUBHEAD:
SUB HEAD : 22.0
WATER PROOFING
22.0 WATER PROOFING

Code No Description Unit Rate


22.1
22.1 Providing
Providing and
and laying
laying integral cement based
integral cement treatment forwater
based treatment for water proofing
proofing
on horizontal surface at all depth below ground level for under ground
on
structures as
as directed by
by Engineer-in-Charge and
and consisting of:
of :
(i)
(i) Ist
Ist layer of 22
layer of 22 mm
mm toto 25
25 mm thick approved
mm thick and specified
approved and specified rough stone
rough stone
slab overa
over a 25 mm thick base ofcement
25 mm of cement mortar 1:31:3 (1
(1 cement
cement::3 3 coarse
sand)
sand) including applying of
including applying of twice(
twice ( at
at base
base and top of
and top of mortar
mortar)) cement
cement
slurry
slurry@@ 2.2kg/m2
2.2kg/m2 (each time) mixed
(each time) with water
mixed with water proofing compound
proofing compound
conforming to IS:2645 in the the recommended proportion over the leveling
course
course (leveling
(leveling course
course toto be
be paid
paid separately). Joints sealed
separately). Joints sealed and
and grouted
grouted
with cement
with cement slurry
slurry mixed with water
mixed with water proofing
proofing compound.
compound.
(ii) 2nd layer
(ii) 2nd of 25
layer of 25 mm thick cement
mm thick cement mortar
mortar 1:3
1:3 (1 cement: 3 coarse
(1 cement:3 sand)
coarse sand)
mixed with water
mixed with water proofing
proofing compound
compound in
in recommended
recommended proportions.
proportions.
(iii)
(iii) Finishing top with
Finishing top with stone
stone aggregate
aggregate of
of 10
10 mm to 12
mm to 12 mm
mm nominal
nominal size
size
spreading@@88 cudm/sqm thoroughly embedded in the
spreading the 2nd
2nd layer.
22.1.1
22.1.1 Using
Using rough
rough kota
kota stone.
stone. sqm
sqm 1515.60
22.2 Providing
Providing andand laying
laying integral cement based
integral cement treatment forwater
based treatment for water proofing
proofing
on the vertical
on the vertical surface
surface by fixing specified
by fixing specified stone
stone slab
slab 2222 mm
mm to to 25
25 mm
mm
thick with
thick with cement
cement slurry
slurry mixed with water
mixed with water proofing
proofing compound conforming
compound conforming
to IS:2645
to IS:2645 inin recommended
recommended proportions with a gap
proportions witha gap ofof 20
20 mm
mm (minimum)
(minimum)
between stone slabs
between stone slabs and
and the
the receiving
receiving surfaces
surfaces and filling the
and filling the gaps
gaps with
with
neat cement slurry
neat cement slurry mixed with water
mixed with water proofing compound and
proofing compound and finishing
finishing
the
the exterior of stone slab with cement mortar mortar11:3:3 (1
(1 cement:3
cement : 3 coarse
sand)
sand) 2020 mm thick with
mm thick with neat
neat cement
cement punning
punning mixed with water
mixed with water proofing
proofing
compound in recommended proportion complete at at all levels and and as
as
directed byby Engineer-in-charge
Engineer-in-charge::
22.2.1
22.2.1 Using
Using rough
rough Kota stone
Kota stone sqm
sqm 2024.70
22.3 Providing
Providing and and laying water proofing
laying water treatment to
proofing treatment to vertical
vertical and
and horizontal
horizontal
surfaces of depressed portions of W.C., kitchen and and the like consisting of:
(i)
(i) Ist course of
Ist course of applying
applying cement slurry @ 4.4
cement slurry@ 4.4 kg/sqm
kg/sqm mixed with water
mixed with water
proofing
proofing compound
compound conforming
conforming to to IS
IS:: 2645
2645 inin recommended
recommended proportions
proportions
including
including rounding off junction of
rounding offjunction vertical and
of vertical and horizontal
horizontal surface.
surface.
(ii)
(ii)IIInd
Ind course of 20
course of 20 mm cement plaster
mm cement plaster 1:3
1:3 (1(1 cement
cement::3 3 coarse sand)
coarse sand)
mixed
mixed with with water
water proofing
proofing compound
compound in in recommended
recommended proportion
proportion
including
including rounding off junction of
rounding offjunction vertical and
of vertical and horizontal
horizontal surface.
surface.
(iii)
(iii) IIIrd course of
IIIrd course of applying
applying blown
blown or or residual
residual bitumen
bitumen applied
applied hot
hot at
at 1.7
1.7
kg. per sqm sqm of area.
(iv)
(iv) IVth IVth course
course ofof 400
400 micron thick PVC
micron thick PVC sheet.
sheet. (Overlaps
(Overlaps at at joints
joints of
of
PVC
PVC sheet should be
sheet should be 100
100 mm wide and
mm wide and pasted
pasted to to each other with
each other with bitumen
bitumen
@@ 1.7 1.7 kg/sqm).
kg/sqm). sqm
sqm 769.60
22.4 Providing
Providing and and Placing
Placing in in position suitable PVC
position suitable water stops
PVC water conforming to
stops conforming to
IS:12200 forconstruction/
for construction/ expansion joints between two RCC RCC members
and fixed
and fixed to
to the
the reinforcement
reinforcement withwith binding wire before
binding wire before pouring
pouring concrete
concrete
etc. complete
complete::
22.4.1
22.4.1 Serrated with central
Serrated with central bulb
bulb (225
(225 mm wide, 8-11
mm wide, 8-11 mm thick)
mm thick) metre 327.65
22.4.2 Dumb
Dumb bell with central
bell with central bulb
bulb (180
(180 mm wide, 8 mm
mm wide,8 thick)
mm thick) metre 267.90
22.4.3 Kickers
Kickers (320
(320 mm wide, 5 mm
mm wide,5 thick)
mm thick) metre 263.65
22.5 Providing and laying
Providing and water proofing
laying water treatment in
proofing treatment in sunken
sunken portion of WCs,
portion of WCs,
bathroom etc., by
bathroom etc., applying cement
by applying slurry mixed
cement slurry with water
mixed with water proofing
proofing
cement compound consisting of applying
applying::

SUB HEAD:: 22.0 WATER PROOFING


SUB 331
Code No Description Unit Rate
(a)
(a) First
First layer of slurry
layer of slurry of
of cement@
cement @ 0.488
0.488 kg/sqm
kg/sqm mixed with water
mixed with water
proofing
proofing cement
cement compound
compound@@ 0.253
0.253 kg/
kg/ sqm. This layer
sqm. This will be
layer will be allowed
allowed
to air cure for
for44 hours.
(b)
(b) Second
Second layer of slurry
layer of slurry of
of cement
cement@@ 0.242
0.242 kg/sqm
kg/sqm mixed with water
mixed with water
proofing
proofing cement
cement compound
compound@@ 0.126
0.126 kg/sqm. This layer
kg/sqm. This will be
layer will be allowed to
allowed to
air cure for
for44 hours followed with water curing for48
for 48 hours.
The
The rate includes preparation of surface, treatment and and sealing of all
joints, corners, junctions of pipes and
and masonry with polymer mixed slurry. sqm
sqm 617.05
22.6 Providing and laying
Providing and water proofing
laying water treatment on
proofing treatment on roofs of slabs
roofs of slabs by
by applying
applying
cement slurry mixed
cement slurry with water
mixed with water proofing cement compound
proofing cement consisting of
compound consisting of
applying:
(a) after surface
(a) after surface preparation, first layer
preparation, first layer of
of slurry
slurry of
of cement
cement@@ 0.488
0.488 kg/
kg/
sqm
sqm mixed with water
mixed with water proofing cement compound@
proofing cement compound @ 0.253
0.253 kg/sqm.
kg/sqm.
(b)
(b) laying second layer
laying second layer of
of Fibre glass cloth
Fibre glass when thefirst
cloth when the first layer
layer is still
is still
green.
green. Overlaps of joints of
Overlaps ofjoints fibre cloth
of fibre should not
cloth should not be
be less than 10
less than 10 cm.
cm.
(c) third layer
(c) third of 1.5
layer of 1.5 mm thickness consisting
mm thickness consisting of slurry of
of slurry cement @ 1.289
of cement@ 1.289
kg/sqm
kg/sqm mixed with water
mixed with water proofing cement compound
proofing cement compound@@ 0.670 0.670 kg/sqm
kg/sqm
and coarse sand
sand@@ 1.289 kg/sqm. This will be be allowed to to air cure for
for44
hours followed by by water curing for
for 48
48 hours. The
The entire treatment will be be
taken upto 3030 cm
cm onon parapet wall and
and tucked into groove in parapet all
around.
(d) fourth and
(d)fourth and final
final layer of brick
layer of tiling with
brick tiling with cement
cement mortar
mortar (which will be
(which will be
paid forseparately.
for separately.
For the
For the purpose of
of measurement the
the entire treated surface will be
be
measured. sqm
sqm 688.90
22.7 Providing and laying
Providing and laying integral cement based
integral cement water proofing
based water treatment
proofing treatment
including preparation of surface as as required forfor treatment of
of roofs,
balconies, terraces etc consisting of following operations:
operations:
(a) Applying a slurry
(a) Applyinga slurry coat of neat
coat of cement using
neat cement 2.75 kg/sqm
using 2.75 of cement
kg/sqm of cement
admixed with
admixed with water
water proofing compound conforming
proofing compound conforming to to IS. 2645 and
IS. 2645 and
approved by Engineer-in-charge over the RCC RCC slab including adjoining
walls upto 300
300 mm
mm height including cleaning the surface before treatment.
(b)
(b) Laying
Laying brick
brick bats with mortar
bats with mortar using
using broken
broken bricks/brick
bricks/brick bats 25 mm
bats 25 mm
to 115
to 115 mm
mm size with 50%
size with 50% ofof cement
cement mortar
mortar 1:5
1:5 (1 cement :55 coarse
(1 cement: coarse
sand) admixed
sand) admixed with
with water
water proofing
proofing compound
compound conforming
conforming toto IS
IS:: 2645
2645
and approved by Engineer-in-charge over 20 mm thick layer of cement
20 mm
mortar of mix
mortar of mix 1:5
1:5 (1
(1 cement
cement :5 coarse sand)
:5coarse sand) admixed
admixed with
with water
water proofing
proofing
compound conforming to IS:: 2645 and approved by Engineer-in-charge
to IS
to required slope and
and treating similarly the
the adjoining walls upto 300
300 mmmm
height including rounding ofjunctions
of junctions of walls and
and slabs.
(c) After two
(c) After two days
days ofproper
of proper curing
curing applying
applyingaa second coat of
second coat of cement
cement slurry
slurry
using 2.75 kg/
using 2.75 sqm of
kg/ sqm cement admixed
of cement with water
admixed with water proofing
proofing compound
compound
conforming to IS:: 2645 and approved by Engineer-in-charge.
to IS
(d)
(d) Finishing the surface
Finishing the surface with
with 20
20 mm thick jointless
mm thick jointless cement
cement mortar of mix
mortar of mix
1:4
1:4 (1
(1 cement
cement :4 :4 coarse sand) admixed
coarse sand) admixed with
with water
water proofing
proofing compound
compound
conforming to IS:: 2645 and approved by Engineer-in-charge including
to IS
laying glass fibre
laying glass fibre cloth
cloth of
of approved
approved quality
quality in top layer
in top of plaster
layer of and
plaster and
finally finishing
finally finishing the
the surface
surface with
with trowel
trowel with
with neat
neat cement slurry and
cement slurry and making
making
pattern of 300x300 mm mm square3
square 3 mmmm deep.

332
332 sua HeAD
SUB HEAD:: 22.0
22.0 WATER
wAreR PRooFiNG
PROOFING
Code No Description Unit Rate
(e) The whole
(e)The whole terrace
terrace so
so finished
finished shall
shall be flooded with
be flooded with water
water for
foraa minimum
minimum
period of two
period of two weeks
weeks for
for curing
curing and for final test.
and forfinal test. “All
“All above
above operations to be
operations to be
done
done in order and
in order and as
as directed
directed and specified by
and specified the Engineer-in-Charge”:
by the Engineer-in-Charge”:
22.7.1
22.7.1 With average thickness of 120 120 mm
mm and
and minimum thickness
at khurra as
as 65 mm.
65 mm. sqm
sqm 1684.60
22.8 Providing and laying
Providing and four courses
laying four water proofing
courses water treatment with
proofing treatment with bitumen
bitumen
felt over
felt over roofs
roofs consisting
consisting of first and
of first and third
third courses
courses ofof blown
blown bitumen 85/25
bitumen 85/25
or 90/15 conforming to
or to IS:: 702
702 applied hot hot@@ 1.45 Kg Kg per square metre ofof
area for each course,
area foreach second course
course, second of roofing felt
course ofroofing felt type3
type 3 grade-I
grade-I (hessian
(hessian
based self finished
based self finished bitumen felt) and
bitumen felt) and fourth
fourth and
and final
final course of stone
course of grit
stone grit
6 6 mm
mm and
and down size or pea pea sized gravel spread at at66 cubic decimeter
per square metre, including preparation of surface but excluding grading
complete with:
with :
22.8.1
22.8.1 Bitumen felt (hessian
Bitumen felt (hessian base) type 3 gradeI
base) type3 grade I conforming
conforming toto
IS:: 1322
IS sqm
sqm 515.05
22.9 Providing
Providing and and laying six courses
laying six courses waterwater proofing treatment with
proofing treatment with bitumen
bitumen
felt over
felt over roofs
roofs consisting
consisting of of first,
first, third
third and
and fifth
fifth course
course of of blown
blown bitumen
bitumen
85/25 or or 90/15 conforming to to ISIS:: 702
702 applied hot hot@@ 1.45, 1.20 and and 1.45
Kg per square metre of
Kg of area respectively,
respectively, second and fourth courses of of
roofing felt type3
roofing felt type 3 gradeI
grade I conforming
conforming to to ISIS:: 1322
1322 (Hessian
(Hessian based self
based self
finished bitumen
finished felt) , sixth
bitumen felt), and final
sixth and final course
course of of stone
stone grit
grit6 6 mm
mm andand down
down
size or peapea sized gravel spread at at66 cubic decimeter per sqm sqm including
preparation of surface but excluding grading, grading, complete. sqm
sqm 806.45
22.10 Providing
Providing and and laying
laying six
six courses
courses waterwater proofing treatment with
proofing treatment with bitumen
bitumen
felt over
felt over roofs
roofs consisting
consisting of of first,
first, third
third and fifth courses
and fifth courses of of blown
blown oror// and
and
residual bitumen applied hot at 1.45, 1.20 and and 1.70 kg per square metre of of
area
area respectively, second and
respectively, second and fourth
fourth courses
courses of of roofing felt type2
roofing felt type 2 grade
grade
II (fibre
(fibre base self finished
base self finished bitumen
bitumen felt) felt) six
six and final courses
and final courses of of stone
stone grit
grit
6 6 mmmm and
and down size or pea pea sized gravel spread at at66 cubic decimeter per
sqm including preparation of surface, excluding grading,
sqm grading, compete. sqm
sqm 910.85
22.11
22.11 Providing
Providing and and laying six courses
laying six courses waterwater proofing treatment with
proofing treatment with bitumen
bitumen
felt over
felt over roofs
roofs consisting
consisting of of first,
first, third
third and fifth courses
and fifth courses of of blown
blown oror// and
and
residual bitumen applied hot at 1.45, 1.20 and and 1.70 kg per square metre of of
area
area respectively, second and
respectively, second and fourth
fourth courses
courses of of roofing felt type2
roofing felt type 2 grade
grade
II
II (glass fibre base
(glass fibre self finished
base self finished bitumen
bitumen felt)felt) and sixth and
and sixth final course
and final course
of stone grit6
of mm and
grit 6 mm and down size or pea pea sized gravel spread at at66 cubic
decimeter per sqm sqm including preparation of surface but excluding grading, grading,
complete. sqm
sqm 910.85
22.12 Supplying and and applying bituminous solution primer on on roof and and// or wall
surface at at 0.24 litre per
per sqm. sqm
sqm 59.45
22.13 Deduct for omitting in
Deduct foromitting water proofing
in water treatment final
proofing treatment final course
course of of spreading
spreading
stone grit6 mm down size or pea
grit 6 mm pea sized gravel:
gravel :
22.13.1
22.13.1 at66 cudm per
persqm
sqm sqm
sqm 17.55
22.13.2 at
at88 cudm per
persqm
sqm sqm
sqm 22.10
22.14 Grading
Grading roof for water
roof for water proofing treatment with
proofing treatment with
22.14.1
22.14.1 Cement concrete 1:2:4 (1 (1 cement
cement:2 : 2 coarse sand:4
sand : 4 graded
stone aggregate
stone aggregate 2020 mm
mm nominal
nominal size)
size) cum
cum 8042.30
22.14.2 Cement
Cement mortar
mortar 1:3
1:3 (1 cement :3 3 coarse
(1 cement: coarse sand)
sand) cum
cum 16112.10
22.14.3 Cement
Cement mortar
mortar 1:4
1:4 (1cement
(1cement:4: 4 coarse
coarse sand)
sand) cum
cum 15155.60

sua HeAD
SUB HEAD:: 22.0
22.0 WATER
wAreR PRooFiNG
PROOFING 333
CodeNo
Code No Description Unit Rate
22.22 Providing
Providing andand mixing
mixing integral
integral crystalline
crystalline admixture for water
admixture for water proofing
proofing
treatment to RCCRCC structures like basement raft, retaining walls, reservior,reservior,
sewage&& water treatment plant, tunnels/
sewage tunnels / subway and bridge deck etc. at
the
the time ofof transporting of concrete into the the drum ofoftheready-mix
the ready-mix truck,
truck ,
using
using integral
integral crystalline admixture @0.80%
crystalline admixture @0.80% (minimum)
(minimum) to to the
the weight
weight ofof
cement content per
cement content per cubic
cubic meter of concrete)
meter of concrete) or or higher
higher as
as recommended
recommended
by the manufacturer’s specification
by themanufacturer's specification inin reinforced
reinforced cement
cement concrete
concrete at at site
site
of work. The
of work. The material shall meet
material shall the requirements
meet the requirements as as specified
specified in ACI-
in ACI-
212-3R-2010 i.e.
212-3R-2010 i.e. by
by reducing
reducing permeability
permeability ofof concrete
concrete by
by more than 90%,
more than 90%,
compared with control concrete as as per DIN
DIN 1048 and resistant to 16 16 bar
bar
hydrostatic pressure. The The crystalline admixture shall be be capable of of self-
healing of cracks up up toa
to a width of 0.50 mm. mm. TheThe work shall be be carried
out all complete
out all complete as as per specification and
per specification and the
the direction
direction of
of the
the Engineer-
Engineer-
in-charge. The
The product performance shall carry guarantee for for 10 years
against any
any leakage. kg 388.00
22.22A Providing and applying
Providing and applying fibre
fibre reinforced elastomeric liquid
reinforced elastomeric water proofing
liquid water proofing
membrane
membrane withwith resilient
resilient acrylic
acrylic polymers
polymers having
having Sun
Sun Reflectivity
Reflectivity Index
Index
(SRI) of 105
(SRI) of on top
105 on top of
of concrete
concrete roof
roof in three coats
in three coats @10.76
@10.76 litre/
litre/ 10 sqm.
10 sqm.
One
One coat
coat ofof self-priming
self-priming of of elastomeric waterproofing liquid
elastomeric waterproofing liquid (dilution
(dilution
with water
with water in the ratio
in the of 3:1)
ratio of 3:1) and two coats
and two coats of
of undiluted
undiluted elastomeric
elastomeric
waterproofing liquid
waterproofing liquid (dry film thickness
(dry film thickness ofof complete application/system
complete application/system
not
not less than 500
less than 500 microns).
microns). TheThe operation shall be
operation shall be carried
carried outout after
after
scrapping and
and properly cleaning the surface to remove loose particles
with wire brushes, complete in all respect as as per the direction of Engineer-
in-Charge. sqm
sqm 563.10
22.23 and applying integral crystalline slurry of hydrophilic in nature
Providing and
for waterproofing
for waterproofing treatment
treatment toto the
the RCC structures like
RCC structures like retaining walls of
retaining walls of
the basement,
basement, water tanks, roof slabs, podiums, reservior, reservior, sewage&
sewage &
water treatment plant, tunnels/
tunnels / subway and bridge deck etc., prepared
by mixing in the
the ratio of5
of 5::2 2 (5 parts integral crystalline slurry:
slurry :2 2 parts
water) forvertical
water) for vertical surfaces and33::11 (3
surfaces and (3 parts
parts integral
integral crystalline slurry :11
crystalline slurry:
part water) for
part water) for horizontal
horizontal surfaces
surfaces and
and applying the same
applying the from negative
same from negative
(internal) side with
(internal) side with the
the help of synthetic
help of fiber brush.
synthetic fiber The material
brush. The material shall
shall
meet the requirements
meet the requirements as specified in
as specified ACI-212-3R-2010 i.e
in ACI-212-3R-2010 i.e by
by reducing
reducing
permeability
permeability of concrete by
of concrete by more than 90%
more than 90% compared
compared with with control
control
concrete as per DIN DIN 1048 and resistant to 16 16 bar
bar hydrostatic pressure
on negative side. The
on The crystalline slurry shall be be capable of of self-healing
of cracks upup toa
to a width of 0.50 mm. mm. TheThe work shall be be carried out out all
complete
complete asas per specification and
per specification and the
the direction
direction of
of the
the engineer-in-charge.
engineer-in-charge.
The
The product performance shall carry guarantee for10 for 10 years against any any
leakage.
22.23.1
22.23.1 For vertical surface two
For two coats@ sqm per coat
coats @ 0.70 kg per sqm sqm
sqm 472.90
22.23.2 For horizontal surface one
one coat @1.10 kg
kg per
persqm.
sqm. sqm
sqm 362.80
22.23A Providing
Providing&& Applying
Applying polymer
polymer modified, flexible cementatious
modified, flexible cementatious negative
negative
side waterproofing coating
side waterproofing coating with
with elastic
elastic waterproofing
waterproofing polymers
polymers on on interior
interior
wa\\
wall plaster surface in three coats @14.35 kg kg /10sqm.
/10 sqm. one coat of of self
priming
priming ofof cementatious
cementatious waterproofing
waterproofing polymer(dilution with water
polymer(dilution with water in the
in the
ratio of 1:1)
ratio of and two
1:1) and two coats of cementatious waterproofing
coats ofcementatious waterproofing polymer
polymer (dilution
(dilution
with water
with water in the ratio
in the of 3:1
ratio of 3:1 ) ) after
after scrapping
scrapping andand properly
properly cleaning
cleaning the the
surface
surface toto remove
remove pre-existing
pre-existing paint film & loose
paint film& loose particles till plaster
particles till plaster isis
visible, complete in all respect as as per the direction of Engineer-in-Charge. sqm
sqm 447.35

334 sua HeAD


SUB HEAD:: 22.0
22.0 WATER
wAreR PRooFiNG
PROOFING
Code No Description Unit Rate
22.24 Providing
Providing andand applying
applying integral
integral crystalline
crystalline (dry
(dry shake)
shake) ofof hydrophilic
hydrophilic in
in
nature for waterproofing
nature for waterproofing treatment
treatment toto the
the RCC structures like
RCC structures like basement
basement
raft, foundation slab, sewage&
sewage & water treatment plant slab, warehouses
floor, parking
floor, parking structures and water
structures and water tank
tank base
base slab etc. sprinkled
slab etc. sprinkled @0.60
@0.60 kgkg
per sqm orhigher
persqm or higher as
as recommended
recommended by the manufacturer’s specification
by themanufacturer's specification
over the lean concrete of of above cited structures.
structures. The
The material shall
meet the requirements as
meet therequirements as specified
specified in ACI-212-3R-2010 i.e.
in ACI-212-3R-2010 i.e. by
by reducing
reducing
permeability
permeability ofof concrete
concrete by
by more than 85%,
more than 85%, compared control concrete
compared control concrete
DIN 1048 and resistant to 16
as per DIN 16 bar
bar hydrostatic pressure on on negative
side. The
The crystalline dry-shake shall be be capable of of self-healing
self-healing of cracks
up toa
up to a width of 0.50 mm.
mm. The
The work shall be be carried out
out all complete as
per specification and
per specification and the
the direction
direction of
of the
the Engineer-in-charge.
Engineer-in-charge. The The product
product
performance shall carry guarantee for10 for 10 years against any any leakage. sqm
sqm 309.60
22.24A Providing
Providing&& Applying
Applying high quality acrylic
high quality acrylic modified
modified resin
resin based texture
based texture
of
of Dholpur/Red
Dholpur/Red sand
sand stone
stone Pattern with anti
Pattern with algae and
anti algae and UV
UV resistance
resistance
properties to be
properties to be applied
applied asas intermediate finish in
intermediate finish desired pattern
in desired pattern@@ 43.04
43.04
kg/10
kg/10 sqm to form film
sqm toform film of
of 1-
1- 1.5
1.5 mm thickness after
mm thickness after scrapping
scrapping and
and properly
properly
cleaning the surface to remove loose particles from the the plaster surface,
followed by
by top coating with Premium Acrylic Smooth exterior paint with
Silicone additives of required shade by two ormore coats@@ 1.43 litre/10
or more coats
sqm, complete as the direction of Engineer -in-Charge.
-in-Charge. sqm
sqm 597.00
22.25 and applying crystalline mortar by mixing in the
Providing and the ratio of 4.5:
4.5 :11 (4.5
parts crystalline mortar
parts crystalline : 1 part
mortar:1 water) forthe
part water) for the treatment
treatment of faulty construction
offaulty construction
joints, cracks, tie rod
rod holes and
and spalled&
spalled & honeycombed surface of RCC RCC
underground structures like basement, water tanks, bridge deck etc. to
underground
ensure water tightness. TheThe crystallie mortar shall conform tothe EN 1504-
to the EN
33 having
having compressive strength Class
compressive strength Class R4 ≥45 MPa
R4 a45 MPa andand adhesive
adhesive bondbond
strength
strength Class
Class R3R3 ≥1.5
?1.5 MPa. The work
MPa. The work shall
shall be
be carried
carried out all complete
out all complete as as
per specification and
per specification the direction
and the direction of
of the
the engineer-in-charge.
engineer-in-charge. The The product
product
performance shall carry guarantee for10 for 10 years against any any leakage.
22.25.1
22.25.1 For sealing cracks andand faulty construction
construction joints, routed out/
making
making U-shape groove size
U-shape groove 25x25 mm
size 25x25 and then
mm and then primed the
primed the
area with integral crystalline slurry @0.05 kg/running metre
and while
and while the
the surface
surface is tacky filled
is tacky filled the
the groove
groove upto
upto surface
surface
with crystalline mortar @1.50 kg/running metre. Once
crystalline mortar
crystalline mortar is touch dry
is touch dry then
then finally
finally applied
applied two
two coats
coats
of
of integral crystalline slurry @0.05 kg/running metre per coat. metre 547.70
22.25.2 For patching of tie rod rod holes, prepared tie rod rod hole surface
and
and then primed the area with integral crystalline slurry
@0.070 kg/sqm and while the surface is tacky repair and and
then filled
then filled the
the tie
tie rod
rod holes with crystalline
holes with crystalline [email protected]
[email protected]
perhole.
per hole. The
The crystalline mortar should be be tightly rodded into
tie rod
rod holes or packed tightly (For 25x25x25 mm mm tie rod
rod
hole,
hole, use
use 0.040
0.040 kg to fill the
kg tofill the hole)
hole) each hole 23.05
22.26 Providing and
and applying of swellable type water stop tape, 19 19 mm
mm xx 25
25 mm
mm
thick in
thick in linear
linear metre
metre (expansive
(expansive nature) for construction
nature) for construction joints
joints treatment
treatment
of RCC
of RCC structure such as raft slab, retaining walls, water storage tank and and
at the junctions of raft slab with the retaining walls etc.. After cleaning the
at
surface, one
one coat of
of required primer forfor swellable water stop tape shall
be applied throughout the length of the joint @3.78 litre per
be per 240
240 running
metre. Over the
the primed surface swellable type water stop tape shall be be
placed. The work
placed. The work shall
shall be
be carried out all
carried out complete as
all complete as per specification and
per specification and
the
the direction of the
the Engineer-In-Charge. The The product performance shall
carry guarantee for10
for 10 years against any
any leakage. metre 573.45

sua HeAD
SUB HEAD:: 22.0
22.0 WATER
wAreR PRooFiNG
PROOFING 335
SUB HEAD
SUB HEAD:: 23.0
RAIN WATER HARVESTING
&& TUBEWELLS
23.0 RAIN WATER HARVESTING
HARVESTING&& TUBEWELLS

Code No Description Unit Rate


23.1
23.1 Boring/drilling bore well of required dia forcasing/
for casing/ strainer pipe, by
by suitable
method
method prescribed
prescribed inin IS: 2800 (part
IS: 2800 (part I),
I), including
including collecting samples from
collecting samples from
different strata, preparing
different strata, preparing and
and submitting strata chart/
submitting strata chart/ bore
bore log,
log, including
including
hire&& running charges of
hire of all equipments, tools, plants
plants&& machineries
required for
for the job, all complete as per direction of Engineer-in-charge,
90 metre depth below ground level.
upto 90
23.1.1
23.1.1 All types of
of soil
23.1.1.1
23.1.1.1 300 mm
300 mm dia metre 707.75
23.1.1.2 350 mm
350 mm dia metre 774.05
23.1.1.3 400 mm dia
400 mm metre 990.80
23.1.2 Rocky strata including Boulders
23.1.2.1
23.1.2.1 300 mm
300 mm dia metre 1695.10
23.1.2.2 350 mm
350 mm dia metre 1792.85
23.1.2.3 400
400 mmmm dia metre 2131.45
23.2 Boring/drilling bore well of required dia forcasing/ by suitable
for casing/ strainer pipe, by
method
method prescribed
prescribed inin IS: 2800 (part
IS: 2800 (part I),
I), including collecting samples
including collecting samples fromfrom
different strata,
different strata, preparing
preparing and submitting strata
and submitting strata chart/
chart/ bore
bore log,
log, including
including
hire& & running charges of
hire of all equipments, tools, plants
plants&& machineries
required for
for the job, all complete as per per direction of Engineer -in-charge,
-in-charge,
metre&& upto 150
beyond 90 metre 150 metre depth below ground level.
23.2.1
23.2.1 All types of
of soil
23.2.1.1
23.2.1.1 300
300 mmmm dia metre 825.70
23.2.1.2 350
350 mmmm dia metre 917.40
23.2.1.3 400 mm dia
400 mm metre 1238.50
23.2.2 Rocky strata including Boulders
23.2.2.1
23.2.2.1 300 mm dia
300 mm metre 1870.60
23.2.2.2 350 mm dia
350 mm metre 1955.60
23.2.2.3 400 mm dia
400 mm metre 2496.55
23.3 Supplying, assembling, lowering and
Supplying, assembling, lowering fixing in
and fixing vertical position
in vertical position in
in bore
bore
well, unplasticized
well, unplasticized PVC
PVC medium well casing
medium well casing (CM)
(CM) pipe of required
pipe of required dia,
dia,
conforming to to IS: 12818, including required hire and and labour charges,
fittings & accessories
fittings& accessories etc. all complete,
etc. all complete, forall
for all depths,
depths, as
as per direction of
per direction of
-in-charge.
Engineer -in-charge.
23.3.1
23.3.1 100 mm
100 mm nominal size dia metre 672.30
23.3.2 150 mm
150 mm nominal size dia metre 793.25
23.3.3 200 mm
200 mm nominal size dia metre 1113.35
23.4 Supplying, assembling, lowering
Supplying, assembling, lowering and fixing in
and fixing vertical position
in vertical position inin bore well
bore well
unplasticized
unplasticized PVCPVC medium well screen
medium well screen (RMS)
(RMS) pipes with ribs,
pipes with conforming
ribs, conforming
to IS:
to IS: 12818,
12818, including
including hire
hire&& labour
labour charges, fittings & accessories
charges, fittings& etc. all
accessories etc. all
complete, forall as per direction of Engineer-in-charge.
for all depths, as
23.4.1
23.4.1 100 mm
100 mm nominal size dia metre 686.55
23.4.2 150 mm
150 mm nominal size dia metre 807.45
23.4.3 200 mm
200 mm nominal size dia metre 1255.70
23.5 Supplying, filling, spreading&
Supplying, filling, spreading & leveling stone boulders
leveling stone boulders ofof size
size range
range55 cm
cm
to20
to 20 cm, in recharge pit, in the
the required thickness,
thickness, for leads&& lifts, all
for all leads
complete as per direction of Engineer-in-charge. cum
cum 1509.80

SUB HEAD:: 23.0 RAIN WATER HARVESTING&


SUB HARVESTING & TUBEWELLS 339
Code No Description Unit Rate
23.6 Supplying, filling, spreading&
Supplying, filling, spreading & leveling gravels of
leveling gravels of size
size range
range55 mm to 10
mm to 10
mm, in the
mm, the recharge pit, over the existing layer of boulders,
boulders, in required
thickness,
thickness, for all leads
leads&& lifts,
lifts, all complete as per direction of Engineer-
in-charge.
in-charge. cum
cum 1538.25
23.7 Supplying, filling, spreading
Supplying, filling, spreading&& leveling
leveling coarse
coarse sand of size range
sand ofsize range 1.5
1.5 mm
mm
to2
to 2 mmmm in recharge pit, in required thickness over gravel layer, for all
leads&& lifts, all complete as per direction of Engineer -in-charge.
leads -in-charge. cum
cum 1538.25
23.8 Gravel packing in tubewell construction in accordance with IS: 4097,
including
including providing gravel fine/
providing gravel fine/ medium/ coarse, in
medium/ coarse, in required grading &
required grading&
sizes as requirement, all complete as per direction of Engineer-
as per actual requirement,
in-charge.
in-charge. cum
cum 2024.50
23.9 Providing
Providing andand fixing
fixing factory
factory made
made precast
precast RCC
RCC perforated drain covers,
perforated drain covers,
having concrete of of strength not less than M-25, of of size 1000
1000xx 450x50
mm, reinforced with8
mm, mm dia four nos
with 8 mm nos longitudinal
longitudinal&&99 nos nos cross sectional
T.M.T. hoop bars, including providing 50 50 mmmm dia perforations
perforations@@ 100 100 to
125
125 mmmm c/c,
c/c, including
including providing
providing edge
edge binding with M.S.
binding with flats of
M.S. flats of size
size 50
50
mm xx 1.6 mm
mm mm complete, all as as per
per direction of Engineer-in-charge. each 1399.95
23.10 Supplying, assembling, lowering
Supplying, assembling, lowering andand fixing
fixing in vertical position
in vertical position inin bore
bore
well, ERW
well, ERW (Electric
(Electric Resistance Welded) FE
Resistance Welded) 410 mild
FE 410 steel screwed
mild steel screwed andand
socketed/plain ended casing pipes of required dia, conforming to to IS:
4270, ofreputed&
of reputed & approved make, including painted with outside surface
with two
two coats of anticorrosive paint of approved brand and
of anticorrosive manufacture,
and manufacture,
including
including required
required hire hire && labour
labour charges, fittings & & accessories,
charges, fittings accessories, all all
complete, forall
for all depths, as as per direction of Engineer-in-charge.
23.10.1
23.10.1 100 mm
100 mm nominal size dia having minimum wall thickness
5.00 mmmm metre 1359.25
23.10.2 150 mm
150 mm nominal size dia having minimum wall thickness
5.00 mmmm metre 1972.25
23.10.3 200
200 mm mm nominal size dia having minimum wall thickness
5.40 mmmm metre 2442.75
23.11
23.11 Supplying,
Supplying, assembling,
assembling, lowering
lowering and fixing in
and fixing vertical position
in vertical position in
in bore well,
bore well,
ERW
ERW (Electric
(Electric Resistance Welded) FE
Resistance Welded) 410 plain
FE 410 plain slotted
slotted (having slot of
(having slot of
size
size 1.6/3.2
1.6/3.2 mm)
mm) mild steel threaded
mild steel threaded and
and socketed/
socketed/ plain
plain bevel ended pipe
bevel ended pipe
(type A) of
(type A) of required
required dia,
dia, conforming
conforming to to IS: 8110, of
IS: 8110, of reputed
reputed and approved
and approved
make, having wall thickness not less than 5.40 mm, mm, including painted
with outside surface with two two coats of anticorrosive bitumestic paint of
of anticorrosive
approved
approved brand
brand and
and manufacture,
manufacture, including
including hire
hire&& labour
labour charges, fittings
charges, fittings
& & accessories,
accessories, all complete, forfor all depths, as as per direction of Engineer
-in-charge.
-in-charge.
23.11.1
23.11.1 100 mm
100 mm nominal size dia metre 1456.80
23.11.2 150 mm
150 mm nominal size dia metre 2102.25
23.11.3 200 mm nominal size dia
200 mm metre 2571.05
23.12 Development
Development of of tube
tube well
well in
in accordance
accordance withwith IS
IS:: 2800
2800 (part
(part I)
I) and
and IS:
IS:
11189, to establish maximum rate of useable water yield without sand
content (beyond
content (beyond permissible
permissible limit), with required
limit), with required capacity air compressor,
capacity air compressor,
running the compressor for for required time till well is fully developed,
measuring yield of
measuring yield of well
well by
by “V”
“V” notch
notch method
method oror any other approved
any other approved
method, measuring static level level&& draw down etc. by by step draw down
method, collecting water samples
samples&& getting tested in approved laboratory,
laboratory,
disinfection of tubewell, all complete, including hire
including disinfection hire& & labour
charges ofair
of air compressor, tools&
tools & accessories etc., all asas per
per requirement
and
and direction of Engineer-in-charge. hour 1085.05

340
340 SUB HEAD : 23.0 RAIN WATER HARVESTING & TUBEWELLS
Code No Description Unit Rate
23.13 Providing
Providing and fixing suitable
and fixing size threaded
suitable size threaded mild
mild steel cap or
steel cap or spot welded
spot welded
plate to the
the top
top of bore well housing/ casing pipe, removable as per per
requirement, all complete forborewell
requirement, for borewell of:
23.13.1
23.13.1 100 mm
100 mm dia each 224.10
23.13.2 150 mm
150 mm dia each 246.45
23.13.3 200 mm dia
200 mm each 321.15
23.14 Providing and fixing
Providing and fixing M.S. clamp of
M.S. clamp of required dia to
required dia to the
the top
top of
of casing/
casing/
housing
housing pipe of tubewell
pipe of tubewell as
as per
per IS: 2800 (part
IS: 2800 (part I),
I), including
including necessary
necessary
bolts&& nuts of required size complete.
bolts
23.14.1
23.14.1 100 mm
100 mm clamp each 1911.40
23.14.2 150 mm
150 mm clamp each 2019.05
23.14.3 200 mm clamp
200 mm each 2293.65
23.15 Providing and fixing
Providing and fixing Bail
Bail plug/
plug/ Bottom
Bottom plug of required
plug of dia to
required dia to the
the bottom of
bottom of
pipe
pipe assembly
assembly of tubewell as
oftubewell as per
per IS:2800
IS:2800 (part
(part I).
I).
23.15.1
23.15.1 100 mm
100 mm dia each 265.10
23.15.2 150 mm
150 mm dia each 322.00
23.15.3 200 mm dia
200 mm each 357.60

SUB HEAD:
SUB HEAD : 23.0 RAIN WATER HARVESTING&
HARVESTING & TUBEWELLS 341
SUB HEAD
SUB HEAD:: 24.0
CONSERVATION OF
HERITAGE BUILDINGS
24.0 CONSERVATION OF HERITAGE BUILDINGS

Code No Description Unit Rate


24.1
24.1 Raking out
out joints of stone masonry surface to the required width and and
depth, with due
due care and by mechanical
and precaution, by mechanical// manual means,
including
including preparing and cleaning
preparing and the surface
cleaning the for re-pointing/
surface for re-pointing/ refilling of
refilling of
joints, including disposal of rubbish to the dumping ground within 50 50
metre lead. sqm
sqm 72.45
24.2 Providing
Providing andand fixing
fixing double
double scaffolding system (cup
scaffolding system (cup lock type) on
lock type) the
on the
exterior side of building/structure, upto 25 25 metre height, above ground
level,
level, including additional rows
including additional of scaffolding
rows of scaffolding in
in stepped
stepped manner
manner as as per
per
requirement of of site, made with 40 40 mmmm dia M.S. tube, placed 1.5 1.5 metre
centre to centre, horizontal
horizontal&& vertical tubes joint with cup
cup&& lock system
with M.S. Tubes, M.S. tube challis,
challis, M.S. clamps and staircase system in
the scaffolding
the for working
scaffolding for working platform etc. and
platform etc. and maintaining
maintaining itit in
ina a serviceable
serviceable
condition forfor execution of of work of of cleaning and/ or pointing and/ or or
applying chemical and
applying chemical and removing
removing itit thereafter.
thereafter. The
The scaffolding
scaffolding system
system
shall
shall be stiffened with
be stiffened with bracings,
bracings, runners, connecting with
runners, connecting with the
the building etc,
building etc,
wherever required, if feasible, for inspection of work atrequired
at required locations
with essential safety features for for the workmen etc., complete as per
directions and
and approval of of Engineer-in-charge.
Note:-
Note:- (1) The elevational
(1) The elevational area
area of the scaffolding
of the scaffolding shall
shall be
be measured
measured forfor
payment
payment purpose.
purpose. (2) The payment
(2)The will be
payment will be made once only
made once for execution
only for execution
of all items forsuch
of for such works. sqm
sqm 338.25
24.3 Cleaning the sand stone surface and and removing dirt, dust, bird dropping,
grease, oil, algae, fungus, monkey beats, vegetable growth etc., including
providing, applying and and washing the the surface with liquid Ammonia
Chemical
Chemical ofof 5% solution and
5% solution and other
other chemical cleaning agent
chemical cleaning agent as approved
as approved
by Archaeological Survey ofIndia/
of India/ Engineer-in-charge, of approved brand
and manufacturer,
and manufacturer, with the help of required scrubbers and and also cleaning
with machine
with operated water
machine operated water jetmixed
jet mixed with
with desired
desired quantity
quantity of fine silica
of fine silica
where ever required, without causing any any scratching/ damage to to the
the
stone surface and
stone surface finally washing
and finally washing thethe surface with clean
surface with clean water
water with
with the
the
help of pressure jet machine, complete in all respect, including taking
all precautions to safeguard ventilators,
ventilators, windows, doors etc. by by suitable
covering so as to avoid any
so as any damage tothebuilding/structure,
to the building/structure, all as per
as per
direction of Engineer-in-charge (The rate is inclusive of all materials
materials&&
labours
labours involved
involved except scaffolding).
except scaffolding). sqm
sqm 211.05
24.4 Providing
Providing and applying antifungal
and applying wash treatment
antifungal wash treatment using
using 3%3% solution
solution
of sodium pentachlorophenate, of of reputed brand and manufacturer,
and manufacturer,
on cleaned sand stone surface at desired locations as
on as per
per direction
of Engineer-in-charge (The rate is inclusive of all materials
materials&& labours
involved except scaffolding).
involved except scaffolding). sqm
sqm 77.90
24.5 Ruled// Flush pointing on
Ruled on Red
Red sand stone masonry surface with lime,
surkhi and
and marble dust mortar in the the ratio of 1:1.5:1/2 {One lime: 1.5 1.5
surkhi
surkhi (50%
(50% red
redandand 50%
50% light yellow surkhi
light yellow surkhi )):: 1/2
1/2 marble dust}. (The
marble dust}. (The rate
rate
is
is inclusive of all
inclusive of all materials
materials&& labours
labours involved
involved except scaffolding).
except scaffolding). sqm
sqm 374.30
24.6 Ruled/ Flush pointing on on White sand stone masonry surface with lime,
and marble dust mortar in the
surkhi and the ratio of 11:1.5:1/2
:1.5:1/2 (One lime:: 1.5
{One lime 1.5
surkhi
surkhi (15% dark red
(15% dark red and
and 85%
85% light yellow surkhi):
light yellow surkhi) : 1/2
1/2 marble dust}. (The
marble dust}. (The
rate
rate is
is inclusive of all
inclusive of all materials
materials&& labours
labours involved
involved except
except scaffolding).
scaffolding). sqm
sqm 374.30

SUB HEAD:: 24.0 CONSERVATION OF HERITAGE BUILDINGS


SUB 345
Code No Description Unit Rate
24.7 Applying two
two or more coat of of Ethyl Silicate chemical as approved by
Archaeological Survey of of India/ Engineer-in-charge, of approved brand
and manufacturer,
and manufacturer, with brush or spray on on the existing stone masonry
surface till there is no
no further absorption of chemical by stone surface,
including protecting the
the applied surface from direct sunlight by by suitable
means during application,
application, all complete as per
per direction of the
the Engineer-
in-Charge (The rate is inclusive of all materials
materials&& labours involved except
scaffolding).
scaffolding). sqm
sqm 329.05
24.8 Applying breathable, non-reactive,
non-reactive, antifungal, and
and water repellant Silane/
Siloxane chemical as approved by Archaeological Survey of of India/
Engineer-in-charge, of approved brand and manufacture, diluted with
and manufacture,
solvent mineral Turpentine oil in thethe ratio of 1:12 (One part of approved
chemical
chemical :12
:12 Part
Part of Turpentine oil),
of Turpentine on the
oil), on the existing
existing sand stone masonry
sand stone masonry
surface with two
two or more coats to give uniform application
application of chemical on
on
the surface, all complete as perper direction of Engineer-In-charge (The rate
is
is inclusive of all
inclusive of all materials
materials&& labours
labours involved
involved except scaffolding).
except scaffolding). sqm
sqm 109.90

346
346 SUB HEAD:: 24.0 CONSERVATION OF HERITAGE BUILDINGS
SUB
SUB HEAD
SUB HEAD:: 25.0
STRUCTURAL GLAZING
ALUMINIUM
COMPOSITE PANEL
25.0 STRUCTURAL GLAZING ALUMINIUM COMPOSITE PANEL

Code No Description Unit Rate


25.1
25.1 Providing and
and supplying aluminium extruded tubular andand other aluminium
sections as
as per the architectural and approved shop drawings,
architectural drawings and drawings ,
the
the aluminium quality asas per
per grade 6063 T5 orT6 perBS
or T6 as per 1474,incIuding
BS 1474,including
super durable powder coating of 60-80 microns conforming toAAMA2604
to AAMA 2604
ofrequired
of and shade as approved by the
required colour and Engineer-in-Charge.((
the Engineer-in-Charge.
The
The item includes cost of material such as cleats, sleeves,
sleeves, screws etc.
necessary forfor fabrication of extruded aluminium frame work. Nothing
extra
extra shall
shall be
be paid on this
paid on this account).
account). The
The weight
weight of
of aluminium extruded
aluminium extruded
section shall be
be taken forpurpose
for purpose of
of payment. kg 414.30
25.2 Designing, fabricating, testing,
Designing, fabricating, testing, protection,
protection, installing and fixing
installing and fixing in
in position
position
semi
semi (grid)
(grid) unitized
unitized system
system of of structural
structural glazing
glazing (with open joints)
(with open joints) for
for
linear as
as well as
as curvilinear portions of the
the building for all heights andand all
levels, including:
levels,
(a)
(a) Structural analysis & design
Structural analysis& design and
and preparation of shop
preparation of shop drawings
drawings forfor the
the
specified design loads
specified design conforming to
loads conforming to IS
IS 875
875 part
part III
III (the system must
(the system must
passed thethe proof test at 1.5 times design wind pressure without any any
failure), including
failure), functional design
including functional design of the aluminum
of the aluminum sections for fixing
sections for fixing
glazing panels of of various thicknesses,
thicknesses, aluminium cleats, sleeves and and
gaskets, screws, toggles, nuts, bolts, clamps etc.,
splice plates etc. gaskets,
structural
structural and weather silicone
and weather silicone sealants,
sealants, flashings,
flashings, fire
fire stop
stop (barrier)-
(barrier)-
cum-smoke seals, microwave cured EPDM gaskets forwater for water tightness,
tightness,
pressure
pressure equalisation
equalisation && drainage
drainage and
and protection
protection against fire hazard
against fire hazard
including:
including:
(b)
(b) Fabricating and supplying
Fabricating and supplying serrated
serrated M.S.
M.S. hot dip galvanised / Aluminium
hotdipgalvanised/ Aluminium
alloy of 6005
alloy of T5 brackets
6005 T5 brackets of
of required
required sizes, sections and
sizes, sections and profiles etc. to
profiles etc. to
accommodate33 Dimentional movement forachieving
accommodate for achieving perfect verticality
and fixing structural
and fixing glazing system
structural glazing system rigidly to the
rigidly to the RCC/
RCC/ masonry/structural
masonry/structural
steel framework of of building structure using stainless steel anchor
fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts
and washers etc. of stainless steel grade 316, of
and of the required capacity
and in required numbers.
and
(c)
(c) Providing and filling,
Providing and filling, two
two part
part pump filled, structural
pump filled, silicone sealant
structural silicone sealant
and
and one
one part weather silicone sealant compatible with the structural structural
silicone sealant of required bite size inina a clean and
and controlled factory / /
work shop environment, including double sided spacer tape, setting
and backer rod, all of
blocks and of approved grade, brand and manufacture, as
and manufacture, as
per the approved sealant design, within and and all around the
the perimeter for
for
holding glass.
(d)
(d) Providing
Providing and fixing in
and fixing in position flashings of
position flashings of solid
solid aluminium
aluminium sheet
sheet 11
mm thick and
mm thick and of
of sizes,
sizes, shapes
shapes and
and profiles, as required
profiles, as as per
required as the site
per the site
conditions,
conditions, to seal the gapgap between the the building structure and
and all its
interfaces with curtain glazing to make it watertight.
watertight.
(e)
(e) Making
Making provision for drainage
provision for drainage ofof moisture/ water that
moisture/ water that enters the
enters the
curtain glazing system to to make it watertight, byby incorporating principles
of pressure
of equalization, providing
pressure equalization, providing suitable
suitable gutter
gutter profiles
profiles at
at bottom
bottom (if
(if
required),
required), making
making necessary
necessary holes of required
holes of sizes and
required sizes and ofof required
required
numbers etc. complete. This item includes cost of all inputs of designing,
designing,
labour for
for fabricating and
and installation of aluminium grid, installation
installation of
glazed units,
glazed T&P, scaffolding
units, T&P, scaffolding and other incidental
and other charges including
incidental charges including
wastages etc., enabling temporary structures and and services, cranes or
cradles etc.
cradles as described
etc. as described above
above and
and as specified.
as specified.

Gi.AZING ALUMINIUM COMPOSITE PANEL


SUB HEAD : 25.0 STRUCTURAL GLAZING 349
Code No Description Unit Rate
The
The item includes the cost of getting all the the structural and and functional
design including shop drawings checked by byaa structural designer, dully
approved by Engineer-in-charge. The The item also includes the cost of all
mock ups ups at atsite,
site, cost of all samples of of the
the individual components for for
testing in
testing in anan approved
approved laboratory, field tests
laboratory, field tests on
on the
the assembled
assembled working working
structural glazing as
structural glazing specified, cleaning
as specified, cleaning and and protection till the
protection till the handing
handing
over ofofthe
the building for occupation. In the the end, the Contractor shall provide
aa water tight structural glazing having all the the performance characteristics
etc. all complete as required, as as per per the
the Architectural
Architectural drawings, as as per
item description, as
item description, as specified,
specified, asas per the approved
per the approved shopshop drawings
drawings and as
and as
directed by by the Engineer- in-Charge.
Note:- 1. The The cost of providing extruded aluminium frames, shadow
boxes, extruded aluminium
boxes, extruded aluminium section
section capping
capping forfixing
for fixing in the grooves
in the grooves of of
the
the curtain glazing and and vermin proof stainless steel wire mesh shall be be
paid for
for separately under relevant items under this sub- head. However,
forthe
for the purpose of of payment, only the actual area of of structural glazing
(including
(including widthwidth ofof grooves)
grooves) on the external
on the external face
face shall
shall be
be measured
measured in in
sqm. up totwoto two decimal places.
Note:-2. The The following performance test are are to be
be conducted on on structural
glazing system if area of of structural glazing exceeds 2500 Sqm Sqm from the
certified
certified laboratories
laboratories accreditated
accreditated by by NABL(National Accreditation Board
NABL(National Accreditation Board
for Testing
for Testing and and Calibration
Calibration Laboratories),
Laboratories), Department
Department of of Science
Science &&
Technologies,
Technologies, India. Cost oftesting separately.
of testing is payable separately.
The
The NITNIT approving authority will decide the necessity of testing on on the
the
basis of cost of the work, cost of the test and and importance of of the work.
Performance Testing of Structural
Structural glazing system Tests to be be conducted in
the
the NABL accredited lab or any any other accreditation body which operates in
accordance with ISO/IEC 17011 17011 and
and accredits labs as as per ISO/IEC 17025
1.
1. Performance
Performance Laboratory Test forAir
Laboratory Test for Air Leakage
Leakage TestTest (-50pa
(-50pa to to -- 300pa)&
300pa) &
(+50pa
(+50pa to to +300pa)
+300pa) as as per ASTM E-283-04
perASTM testing method
E-283-04 testing method for foraa range
range ofof
testing limit
testing limit11 to
to 200
200 mVhr
mVhr
2. Static
2. Water Penetration
Static Water Test. (50pa
Penetration Test. (50pa to to 1500pa)
1500pa) as as per ASTME- 331-09
perASTME- 331-09
testing method for foraa range up to to 2000 ml. ml.
3. Dynamic Water
3.Dynamic Water Penetration
Penetration (50pa
(50pa to to 1500pa)
1500pa) as as per AAMA 501.01-
perAAMA 501.01- 0505
testing method for foraa range upto 2000 ml
4. Structural
4. Structural Performance
Performance Deflection
Deflection and and deformation
deformation by static air
by static air
pressure
pressure test test (1.5 times design
(1.5 times design wind
wind pressure without any
pressure without failure) as
any failure) as per
per
ASTME-330-10 testing method for foraa range upto 50 50 mmmm
5. Seismic
5. Seismic Movement
Movement Test Test (upto
(upto 3030 mm)
mm) as as per AAMA 501.4-09
per AAMA 501.4-09 testingtesting
method forQualitative
for Qualitative test, Tests to be be conducted on site.
on site.
6.
6. Onsite Test forWater
for Water Leakage forforaa pressure range 50 kpa to to 240
240 kpa
(35psi)
(35psi) upto 2000 ml
upto 2000 ml sqm
sqm 3510.50
25.3 Providing,
Providing, assembling
assembling andand supplying vision glass
supplying vision glass panels
panels (IGUs)
(IGUs)
comprising ofof hermetically-sealed 6-12-6
6-12- 6 mmmm insulated glass (double
glazed) vision
glazed) vision panel
panel units of size
units of and shape
size and shape as as required and specified,
required and specified,
comprising of
comprising of an
an outer
outer heat strengthened float
heat strengthened float glass
glass66 mm thick, of
mm thick, of
approved colour
approved colour and
and shade with reflective
shade with reflective soft
soft coating
coating on on surface#
surface #22 of of
approved colour
approved and shade,
colour and shade, anan inner
inner Heat
Heat strengthned
strengthned clearclear float
float glass
glass
66 mm
mm thick, spacer tube 12 mmmm wide, dessicants,
dessicants, including primary seal
and secondary
and seal (structural
secondary seal silicone sealant)
(structural silicone etc. all
sealant) etc. complete forthe
all complete for the
required performances, as per the Architectural drawings, as as per the
approved shop
approved drawings, as
shop drawings, specified and
as specified and as directed by
as directed the Engineer-
by the Engineer-
in-Charge. The IGUs
in-Charge. The IGUs shall
shall be
be assembled
assembled in the factory/
in the factory/ workshop
workshop of the
ofthe
glass processor.

350
350 SUB HEAD:: 25.0 STRUCTURAL GLAZING Ai.UMINIUM
SUB ALUMINIUM COMPOSITE PANEL
Code No Description Unit Rate
(Payment for fixing of
(Payment forfixing of IGU
IGU Panels
Panels in the curtain
in the curtain glazing
glazing is
is included
included in
in cost
cost
of
of item
item No.25.2)
No.25.2)
For
For payment, only the
payment, only the actual
actual area
area ofglass
of glass on
on face#
face #11 of
of the
the glass
glass panels
panels
(excluding the areas
(excluding the of the grooves
areas ofthe grooves and weather silicone
and weather silicone sealant)
sealant) provided
provided
and fixed in
and fixed in position,
position, shall
shall be
be measured
measured inin sqm.
sqm.
(i)
(i) Coloured tinted float
Coloured tinted float glass6
glass 6 mm thick substrate
mm thick with reflective
substrate with soft
reflective soft
coating on face#
coating on face # 2,+2, + 1212 mm Airgap +66 mm
mm Airgap+ mm Heat
Heat Strengthened
Strengthened clear
clear
Glass of
of approved make having properties as as visible Light transmittance
(VLT) of 25
(VLT) of 25 toto 35
35 %,
%, Light
Light reflection
reflection internal
internal 10 to 15%,
10 to 15%, light
light reflection
reflection
external
external 10 to 20
10 to 20 %, shading coefficient
%, shading coefficient (0.25-
(0.25- 0.28) andUU value
0.28) and value of
of 3.0
3.0
to 3.3 W/m2 degreeK
degree K etc. The The properties of performance glass shall be be
decided by technical sanctioning authority as as per
per the requirement.
the site requirement. sqm
sqm 3718.70
25.4 Extra for openable
Extra for side / top
openable side/ top hung vision glass
hung vision glass panels
panels (IGUs)
(IGUs) including
including
and supplying at site all accessories and
providing and and hardwares for
for the
the
openable
openable panels as specified
panels as and of
specified and the approved
of the approved make such as
make such as heavy
heavy
duty stainless steel friction hinges, min
min44 -point cremone locking sets with
stainless
stainless steel
steel plates,
plates, handles,
handles, buffers
buffers etc.
etc. including
including necessary stainless
necessary stainless
steel screws/ fasteners, bolts, washers etc. all complete as per the
fasteners, nuts, bolts,
Architectural drawings,
Architectural drawings, as
as per the approved
per the approved shopshop drawings,
drawings, as specified
as specified
and as
and by the
as directed by the Engineer- in-Charge. sqm
sqm 3671.50
25.5 Providing, fabricating and
Providing, and supplying shadow box box of
of required size and and
shape, for fixing in
shape, forfixing the spandrel
in the spandrel portion of the
portion of the structural
structural glazing,
glazing, inin linear
linear
as well as
as as curvilinear portions of the building by by providing semi -rigid,
inorganic,
inorganic, non-combustible
non-combustible fibre fibre glass
glass wool
wool insulation
insulation 5050 mm thick,
mm thick,
conforming to to IS: 8183 and BS: 3958 Part 5. S. The
The insulation layer shall
have facing (factory
have facing (factory bonded
bonded on on surface#
surface #11 of of the
the fibre
fibre glass
glass insulation
insulation
layer), of black
layer), of black non-woven fibre glass
non-woven fibre glass tissue
tissue of
of nominal thickness 0.5
nominal thickness 0.5 mmmm
and nominal mass not
and notless
less than 60 60 gm
gm /sqm, made ofrandomly
of randomly oriented
glass fibres distributed
glass fibres distributed in
ina a binder
binder by
byaa wet-lay
wet-lay process
process including fixing 1.5
including fixing 1.5
mm thick solid aluminum sheet backing using,
mm using,66 mmmm thick cement board
including SSSS rivets, nuts, bolts,
bolts, washers etccomplete.
etc complete. sqm
sqm 2159.65
25.6 and supplying Spandrel Glass Panels comprising of
Providing and of66 mm
mm thick
heat
heat strengthened
strengthened monolithic float glass
monolithic float glass of approved colour
of approved colour and
and shade
shade
with reflective
with soft coating
reflective soft coating on
on surface#
surface #22 of
of approved
approved colour and shade
colour and shade
so as to
so as to match the colour
match the colour and
and shade of the
shade of the IGUs
IGUs in the vision
in the vision panels
panels
etc.
etc. ,all
,all complete for the required
complete forthe required performances as specified,
performances as specified, as
as per the
per the
Architectural drawings,
Architectural drawings, asas per the approved
per the approved shop
shop drawings, as specified,
drawings, as specified,
and as
and as directed byby the
the Engineer- in- Charge.
For
For payment, only the
payment, only the actual
actual area
area ofglass
of glass on
on face#
face #11 of the glass
of the glass panels
panels
(but
(but excluding
excluding thethe area of grooves and
area ofgrooves weather silicone
and weather silicone sealant)
sealant) provided
provided
and fixed in
and fixed in position,
position, shall
shall bebe measured
measured in sqm. (Payment
in sqm. (Payment forfor fixing
fixing of
of
Spandrel Glass Panels in the the curtain glazing is included in cost of relevent
Item*).“(i)
Item*).“(i) Coloured tinted float
Coloured tinted float glass
glass66 mm thick substrate
mm thick substrate with
with reflective
reflective
soft
soft coating
coating on face # 2,
on face# 2, having
having properties
properties asas visible
visible Light transmittance
Light transmittance
(VLT)
(VLT) ofof 25
25 to
to 35
35 %,%, Light
Light reflection
reflection internal
internal 10 to 15%,
10 to 15%, light
light reflection
reflection
external
external 10 to 20
10 to 20 %, shading coefficient
%, shading coefficient (0.25-
(0.25- 0.28) andUU value
0.28) and value ofof 3.0 to
3.0 to
3.3 W/m2K
W/m2 K etc..
etc. . The
The properties of performance glass shall be be decided by
technical sanctioning authority as per the
as per the site requirement.
requirement. sqm
sqm 2450.15
25.8 Design supply&& installation
installation of suspended Spider Glazing system designed
to withstand
to withstand the
the wind
wind pressure
pressure asas per
per IS
IS 875
875 (Part-III). The Suspended
(Part-III). The Suspended
System held with Spider Fittings of SS-316 Grade Steel of approved
manufacturer with glass panel having 12 mm mm thick clear toughened glass
held together with SS-
SS- 316
316 Grade Stainless steel Spider
Spider&& bolt assembly
with laminated
with laminated glass fins 21
glass fins 21 mm thick. The
mm thick. The Glass fins
Glass fins

Gi.AZING ALUMINIUM COMPOSITE PANEL


SUB HEAD : 25.0 STRUCTURAL GLAZING 351
Code No Description Unit Rate
and glass panel assembly shall be
and be connected to to Slab/beams by means
of SS-
of SS- 316
316 Grade stainless steel brackets
brackets&& Anchor bolts and and at the
the
bottom using SS SS channel ofof 50x25x2 mm mm using fastener&
fastener & anchor bolts,
non staining weather
non staining weather sealants of approved
sealants of approved make, Teflon/ nylon
make, Teflon/ nylon bushes
bushes
and separators to prevent bi-metallic contacts, all complete to to perform
as
as per
per specification
specification and approved drawings.
and approved drawings. TheThe complete
complete system to be
system to be
designed to to accommodate thermal expansion&
expansion & seismic movements etc.
The joints
The joints between
between glass
glass panels
panels (6 to88 mm)
(6 to mm) and gaps at
and gaps the perimeter
atthe perimeter
&& in
in UU channel
channel ofof the
the assembly
assembly toto be filled with
be filled with non
non staining weather
staining weather
sealant, soso as
as to make theentire
the entire system fully water proof
proof&& dust proof.
The
The rate shall include all design, Engineering and and shop drawing including
approval from structural
approval from designer, labour,
structural designer, T&P, scaffolding,
labour, T&P, scaffolding, other
other incidental
incidental
charges
charges including wastage, enabling
including wastage, enabling temporary
temporary services
services all fitting fixers
all fitting fixers
nut
nut bolts, washer, Buffer
bolts, washer, Buffer plates, fastener, anchors,
plates, fastener, anchors, SS
SS channel
channel laminated
laminated
glass etc. all complete. For the purpose of of payment, actual elevation area
of Glazing including thickness of joints and
of and the
the portion of Glass panel
inside the SS channel shall be
the SS be measured. sqm
sqm 9502.35

352
352 SUB HEAD:: 25.0 STRUCTURAL GLAZING Ai.UMINIUM
SUB ALUMINIUM COMPOSITE PANEL
SUB HEAD
SUB HEAD:: 26.0
NEW TECHNOLOGIES
NEW
AND
AND MATERIALS
NEW TECHNOLOGIES AND
26.0 NEW AND MATERIALS

Code No Description Unit Rate


26.1
26.1 Providing
Providing&& fixing
fixing in
in position
position Phenol
Phenol bonded
bonded Bamboo
Bamboo woodwood flooring
flooring with
with
planks of
of sizes 1414 mm
mm thick, minimum 1800 mm mm length and and minimum 100 100
mm wide, in
mm wide, approved colour,
in approved colour, texture
texture andand finish,
finish, having
having Performance
Performance
Appraisal Certificate
Appraisal Certificate (PAC)
(PAC) issued
issued byby Building
Building Materials
Materials&& Technology
Technology
Promotion
Promotion Council
Council (BMTPC).
(BMTPC). TheThe flooring
flooring shall
shall be fixed with
be fixed with tongue
tongue and
and
interlocking system, with underlayment of
groove interlocking of44 mm
mm thick expanded
polyethylene foam sheets having density 40 40 kg/cum, over prepared
surface with necessary quarter round planks of of size 1900 mm mm xx 18 mm
mm
and door reducer of of size 1900 mmmm xx 44 mm, mm, wherever required. The The
bamboowood planks shall have minimum density of 1000 Kg/cum &&
minimum
minimum Hardness
Hardness 1000 1000 Kgf. with Eco
Kgf. with friendly UV
Eco friendly UV coating,
coating, all
all complete
complete
as per direction of the in-charge.
the Engineer in-charge. sqm
sqm 6145.85
26.2 Providing
Providing&& fixing
fixing in
in position
position Phenol
Phenol bonded
bonded Bamboo
Bamboo woodwood in wall skirting
in wall skirting
with planks
with of sizes
planks of sizes 1414 mm thick, 1900
mm thick, 1900 mmmm length
length (minimum)
(minimum) and and 8585
mm wide(minimum), in
mm wide(minimum), approved colour,
in approved texture and
colour, texture finish, having
and finish, having
Performance Appraisal Certificate
Performance Appraisal Certificate (PAC)
(PAC) issued
issued by
by Building
Building Materials
Materials&&
Technology Promotion
Technology Promotion Council
Council (BMTPC).
(BMTPC). TheThe skirting
skirting shall
shall be fixed with
be fixed with
SS screws
SS screws&& rawl plugs, over underlayment of4 of 4 mmmm thick, expanded
polyethylene foam sheets having 40 40 kg/cum density over prepared
surface. The
The bamboo wood planks shall have minimum density of 1000
Kg/cum
Kg/cum&& minimum
minimum Hardness
Hardness 1000
1000 Kgf. with Eco
Kgf. with friendly UV
Eco friendly coating, all
UV coating, all
complete as per direction of the the Engineer in-charge. sqm
sqm 6033.55
26.3 Providing
Providing&& fixing
fixing in
in position
position Phenol
Phenol bonded
bonded Bamboo
Bamboo wood wood wall
wall cladding
cladding
at all height with planks of sizes 10 10 mm
mm thick, minimum 1800 mm mm length
and
and minimum
minimum 100 100mmmm wide,
wide, in approved colour,
in approved colour, texture
texture and
and finish,
finish, having
having
Performance Appraisal Certificate
Performance Appraisal Certificate (PAC)
(PAC) issued
issued by by Building
Building Materials
Materials&&
Technology Promotion
Technology Promotion Council
Council (BMTPC), with necesasary
(BMTPC), with necesasary profiled edges
profiled edges
fixed with
fixed with 40
40 mmmm SS screws 5 nos
SS screws5 nos in each tile
in each tile to
to frame
frame work
work made
made of of
second class teak wood ofsize of size 20x15 mm mm in centre of each tile and and
bottom and
and top of of work height, 40x15 mm mm placed at at ends ofof each tile.
tile.
The
The cladding shall be be laid over backlayment of of 1.00 mm mm thick expanded
polyethylene foam of
polyethylene foam density 40
ofdensity 40 kg/cum
kg/cum in two layers,
in two first layer
layers, first on wall
layer on wall
surface
surface before fixing wooden
before fixing wooden frame
frame and
and second
second layer on frame
layer on frame under
under
cladding. The
The bamboo wood planks shall have minimum density of 1000
Kg/cum
Kg/cum&& minimum
minimum Hardness
Hardness 1000
1000 Kgf. with Eco
Kgf. with friendly UV
Eco friendly coating, all
UV coating, all
complete as per direction of the the Engineer in-charge. sqm
sqm 6283.85
26.4 Providing
Providing&& fixing
fixing in
in position
position Phenol
Phenol bonded
bonded Bamboo
Bamboo woodwood panelled
panelled or
or
panelled and and glazed shutters fordoors
for doors windows, clerestorey windows with
pre-molded minimum 30 mm mm thick planks, in approved colours, texture&texture &
finish. ItIt shall
finish. shall have
have 10
10 mm wide, 25
mm wide, 25 mm
mm deep grove to
deep grove to fit
fit in
in panels.The
panels.The
bamboo wood shall have minimum density of 1000 Kg/cum, minimum
Hardness
Hardness 1000 1000 Kgf. All styles
Kgf. All and rails
styles and shall have
rails shall have profiled
profiled interlocking
interlocking
system locked in place by by bamboo pins, all complete as per direction of
Engineer
Engineer in charge. (The
in charge. (The panelling will be
panelling will be paid for separately).
paid for separately). sqm
sqm 6935.75
26.5 Providing
Providing&& fixing
fixing in
in position
position Phenol
Phenol bonded
bonded Bamboo wood panelling
Bamboo wood of
panelling of
10 mm
10 mm thick, in 25
25 to
to 40 mm thick panelled or panelled
40 mm panelled&& glazed shutters
for
for doors, windows, clerestorey windows, in approved colour, texture &&
finish. The
finish. The bamboo
bamboo woodwood planks shall have
planks shall have minimum density of
minimum density of 1000
1000
Kg/cum
Kg/cum&& minimum
minimum Hardness
Hardness 1000
1000 Kgf. The panels
Kgf. The shall have
panels shall have profiled
profiled
interlocking system locked in place with bamboo pins all complete as per
interlocking
direction of the
the Engineer in-charge. (area of opening forpanel
for panel inserts
excluding
excluding portion
portion inside grooves or
inside grooves or rebates to be
rebates to be measured)
measured) sqm
sqm 4555.75

SUB HEAD:: 26.0 NEW


SUB NEW TECHNOLOGIES AND
AND MATERIALS 355
Code No Description Unit Rate
26.6 Providing
Providing&& fixing
fixing in
in position
position 65
65 mm thick factory
mm thick factory made door frame
made door frame of
of
Phenol
Phenol bonded
bonded Bamboo wood (superior
Bamboo wood (superior class,
class, interior
interior use),
use), in approved
in approved
colour, texture and
colour, texture and finish.The
finish.The bamboo wood shall
bamboo wood shall have
have minimum density
minimum density
of 1000 Kg/cum, minimum hardness 1000 Kgf. The The door frame shall have
tenon & mortise
tenon& mortise interlocking
interlocking system, to be
system, to fixed to
be fixed to the
the wall
wall with
with 100
100 mm
mm
G.I screws alla
size G.I all a complete as per direction of Engineer-in
Engineer-in charge. cudm 325.95
26.6A Providing,
Providing, erecting,
erecting, laying
laying and fixing in
and fixing in position
position in
in 3.5 to4 4 mm
3.5 to thick
mm thick
bamboo
bamboo mat corrugated sheet
mat corrugated sheet (BMCS)
(BMCS) as as per IS: 15476-2004
perIS: 15476-2004 inin roofing
roofing
with self drilling screws along with EPDM washers complete or or with
ironJ J orL
galvanized iron hooks88 mm
or L hooks mm dia and bitumen washers
dia G.I. plain and
etc, all complete as perper direction of Engineer-in-Charge. sqm
sqm 6012.10
26.6B Providing and fixing
Providing and fixing in
in position
position ridges
ridges of
of 3.5 to 4 mm
3.5 to4 thick bamboo
mm thick bamboo matmat
ridge
ridge cap
cap (BMRC)
(BMRC) as per IS: 15476-2004
asperIS: 15476-2004 inin roofing with self
roofing with drilling screws
self drilling screws
along with EPDM washers complete or orwith ironJ J orL
with galvanized iron hooks88
or L hooks
mm diaG.I.
mm dia G.I. plain and
and bitumen washers etc, all complete as per per direction
of Engineer-in-Charge. metre 4830.10
26.6C Providing and fixing
Providing and fixing at
at all
all height false ceiling
height false ceiling of
of4 4 mm thick phenol
mm thick phenol bonded
bonded
Bamboo
Bamboo Mat board (595x595
Matboard (595x595 mm) mm) conforming
conforming to to IS:13958-1994
IS:13958-1994 including
including
providing
providing and fixing of
and fixing of frame
frame work
work made of GI angle 25x25x0.4
made ofGIangle 25x25x0.4 mm thick
mm thick
all around suitably
all around suitably fixed
fixed toto wall
wall with
with the
the help of dash
help of fastener and
dash fastener and hanger
hanger
frame (600x600
frame (600x600 mm mm c/c)c/c) made
made GI slotted Tee
GIslotted Tee having
having powder
powder coating on
coating on
bottom side (30x25x0.3 mm mm thick for main member
member&& 25x25x0.3 mm mm for
for
cross
cross member)
member) connected
connected to to ceiling with 2.64
ceiling with 2.64 mm mm GI wire and
GI wire anchor
and anchor
fastener at every junction and and also including cost of making openings
for light fittings,
forlight fittings, grills,
grills, diffusers,
diffusers, cut
cut outs
outs made
made withwith frame
frame of
of perimeter
perimeter
channels suitably fixed
channels suitably fixed allall complete
complete as as per direction of
per direction of Engineer-in-
Engineer-in-
charge. sqm
sqm 4039.10
26.6D Providing and fixing
Providing and fixing atat Bamboo
Bamboo MatMat board
board conforming to IS:13958-1994
conforming to IS:13958-1994
for partition to frame by bucking or studding with screws etc. complete
for partition
(Frames,
(Frames, backing
backing oror studding
studding toto be
be paid separately)
paid separately)
26.6D.1
26.6D.1 33 mm
mm thickness sqm
sqm 2942.00
26.6D.2 44 mmmm thickness sqm
sqm 3332.00
26.6D.3 66 mm
mm thickness sqm
sqm 3923.65
26.6D.4 99 mm
mm thickness sqm
sqm 4906.80
26.6D.5 mm thickness
12 mm sqm
sqm 5601.55
26.6E Providing and fixing
Providing and fixing at
at all
all height wall panelling
height wall with phenol
panelling with phenol bonded
bonded Bamboo
Bamboo
Mat board conforming
Matboard conforming to to IS:13958-1994
IS:13958-1994 including
including providing and fixing
providing and fixing to
to
frame work made of of50 50 mmmm xx 50
50 mm
mm hard wood plugs including cutting
brick work and
brick work and fixing
fixing inin cement
cement mortar and making
mortar and making good the wall etc.
good thewall and
etc. and
also
also providing
providing and fixing wooden
and fixing wooden moulded
moulded corner
corner beading of triangular
beading of triangular
shape tothejunction
to the junction of panelling etc. with iron screws all complete as per
direction of Engineer-in-Charge.
26.6E.1
26.6E.1 99 mm
mm thickness sqm
sqm 5127.60
26.6E.2 mm thickness
12 mm sqm
sqm 5824.10
26.7 Providing and fixing
Providing and fixing 50
50 mm thick extruded
mm thick extruded polystyrene
polystyrene rigid
rigid insulation
insulation
ofrequired
board of required size between cavity wall, complying with ISO ISO 4898:2008
&& ASTMC
ASTM C 578-08b
578-08b -- type
type VI,
VI, having thermal conductivity
having thermal conductivity of 0.0289 W/m
of 0.0289 W/m
KK as
as per ASTM C 578
perASTMC (measured as
578(measured as per
per IS
IS 3346), compressive strength
3346), compressive strength
of>> 350
of 350 kPa
kPa listed as per ASTMD
as per ASTM D 1621, density of 34-36 kg/m³ kg/m° as per
ASTM D 1622,
ASTMD water absorptions1
1622, water absorptions ≤ 1% 1% by volume as
by volume as per ASTM D 2842,
perASTMD 2842,
oxygen index of 24.1
24.1 to 28.1 as per
28.1 listed as per ASTMD
ASTM D 2863, cell size 0.4 mm mm
of
of dia
dia (max)
(max) as
as per ASTM D 3576.
perASTMD 3576.

356
356 SUB HEAD:: 26.0 NEW
SUB NEW TECHNOLOGIES AND
AND MATERIAL•S
MATERIALS
Code No Description Unit Rate
Fire retardent property as as per DINDIN 4102, Part Part11 of class B2 B2 and
and asas per
ASTM E84
ASTM class A,
E84class A, fixed
fixed with
with suitable water based
suitable water adhesive and
based adhesive and fastener,
fastener,
complete in all respect as as per the direction of Engineer-in-Charge. sqm
sqm 1004.55
26.8 Providing
Providing and and fixing
fixing 5050 mm thick extruded
mm thick extruded polystyrene
polystyrene rigid rigid insulation
insulation
board of of required size underdeck on ceiling surface, complying with ISO ISO
4898:2008 & ASTMC
4898:2008& ASTM C 578-08b578-08b -- type type VI,
VI, having thermal conductivity
having thermal conductivity
of
of 0.0289
0.0289 W/m W/m KK as as per ASTM C 578
per ASTMC 578 (measured
(measured as as per
per IS IS 3346),
3346),
compressive strength of> 350 kPa
of > 350 kPa listed as per ASTMD
as per ASTM D 1621, density of
34-36
34-36 kg/cum
kg/cum as as per ASTM D 1622,
perASTMD water absorptions
1622, water absorptions1≤ 1% 1% by volume
by volume
perASTMD
as per ASTM D 2842, oxygen index of of 24.1
24.1 to 28.1
28.1 listed as per ASTMD
as per ASTM D
2863, cell
2863, cell size
size 0.4
0.4 mmmm of dia (max)
of dia (max) as as per ASTM D 3576.
per ASTMD 3576. Fire
Fire retardent
retardent
property as as per DIN
DIN 4102, Part Part11 of class B2 B2 and
and asas per ASTM E84 E84class
class
A, fixed
A, fixed with
with suitable
suitable water
water based adhesive and
based adhesive fastener, complete
and fastener, complete in all
in all
respect as as per the direction of Engineer-in-Charge. sqm
sqm 1091.65
26.9 Providing
Providing and and fixing
fixing factory
factory made
made solid
solid Foam
Foam uPVCuPVC profile for kitchen
profile for kitchen
cabinet frame (45
cabinet frame (45xx 20 20 mm)
mm) of of approved
approved shade,
shade, quality and make.
quality and make. The The
profile shall be
profile shall be laminated
laminated on on both
both sides,
sides, made
made fromfrom rigid foam sheets
rigid foam sheets
(Single
(Single extruded)
extruded) having density 600
having density 600 Kg/cum
Kg/cum and and thethe exposed
exposed edgesedges
sealed with PVC
sealed with PVC edgeedge beading
beading of of same shade and
same shade and colour.
colour. TheThe frame
frame
shall
shall be fire retardent
be fire retardent withwith necessary
necessary screwscrew holding capacity. Frame
holding capacity. shall
Frame shall
be fixed to
be fixed to wall
wall using
using Expendable
Expendable Fastner with necesary
Fastner with necesary stainless steel
stainless steel
screws, all complete as per direction of Engineer-in-charge. metre 450.95
26.10 Providing
Providing and and fixing
fixing factory
factory made
made Kitchen
Kitchen Cabinet
Cabinet Shutter/Partition
Shutter/Partition
20 mm
20 mm nominal thickness of approved shade, quality and and make, made
from rigid
from foam sheets
rigid foam sheets (Single extruded) having
(Single extruded) density 600
having density 600 Kg/cum
Kg/cum
and
and laminated
laminated on on both side by
both side by laminate
laminate Sheet/PVC
Sheet/PVC foil foil lamination.
lamination. The The
exposed
exposed edgesedges shall
shall bebe sealed with PVC
sealed with edge beading
PVC edge beading of of same
same shade
shade
and
and colour. The shutter
colour. The shutter shall
shall be fire retardent
be fire retardent having
having necessary
necessary screw screw
holding
holding capacity.
capacity. Shutter shall be
Shutter shall fixed to
be fixed to frame
frame using approved hinges
using approved hinges
with necessary stainless steel screws, all complete as per direction of
Engineer-in-charge. sqm
sqm 5350.55
26.11
26.11 Providing and fixing
Providing and fixing concealed
concealed hinge of approved
hinge of quality for
approved quality for 19-20
19-20 mm
mm
thick door with stainless steel screws complete
complete:: each 144.05
26.12 Supplying && laying of bi-axial extruded high modulus polypropylene
geogrid coforming to to MORTH SPECIFICATION for for base/sub-base
reinforcement having minimum tensile strength 15 15 kN/m in the longitudinal
the longitudinal
and transverse direction,
and transverse direction, with5
with 5 kN/m
kN/m andand77 kN/m tensile strength
kN/m tensile strength at
at 2%
2%
and
and 5%
5% strain
strain respectively
respectively in the longitudinal
in the and transverse
longitudinal and transverse direction,
direction,
junction efficiency
junction efficiency not
not less than 95%
less than and with
95% and with 38
38 mm
mm XX 38 38 mm
mm mesh
mesh
opening. sqm
sqm 249.90
26.13 Supplying && laying of bi-axial extruded high modulus polypropylene
geogrid coforming to to MORTH SPECIFICATION for for base/sub-base
reinforcement having minimum tensile strength 20 20 kN/m in the longitudinal
the longitudinal
and transverse direction,
and transverse direction, with7
with 7 kN/m
kN/m andand 14
14 kN/m tensile strength
kN/m tensile at 2%
strength at 2%
and
and 5% strain respectively
5% strain respectively in the longitudinal
in the and transverse
longitudinal and transverse direction,
direction,
junction efficiency
junction efficiency not
not less than 95%
less than and with
95% and with 38
38 mm
mm XX 3838 mm
mm mesh
mesh
opening. sqm
sqm 276.50
26.14 Supplying && laying of bi-axial extruded high modulus polypropylene
geogrid coforming to to MORTH SPECIFICATION for for base/sub-base
reinforcement having minimum tensile strength 30 30 kN/m in the longitudinal
the longitudinal
and transverse direction, with 10.5 kN/m and 21 kN/m tensile strength at
and
2% and
2% and 5%
5% strain
strain respectively
respectively in the longitudinal
in the longitudinal and transverse direction,
and transverse direction,
junction efficiency
junction efficiency not
not less than 95%
less than and with
95% and with 38
38 mm
mm XX 3838 mm
mm mesh
mesh
opening. sqm
sqm 401.70

SUB HEAD:: 26.0 NEW


SUB NEW TECHNOLOGIES AND
AND MATERIALS 357
Code No Description Unit Rate
26.15 Supplying && laying of bi-axial extruded high modulus polypropylene
geogrid coforming to to MORTH SPECIFICATION for for base/sub-base
reinforcement having minimum tensile strength 40 40 kN/m in the longitudinal
the longitudinal
and transverse direction, with 14
and 14 kN/m and 28 kN/m tensile strength at
2%
2% and
and 5%
5% strain
strain respectively
respectively in the longitudinal
in the longitudinal and transverse direction,
and transverse direction,
junction efficiency
junction efficiency not
not less than 95%
less than and with
95% and with 38
38 mm
mm XX 38 38 mm
mm mesh
mesh
opening. sqm
sqm 555.05
26.16 Supplying&& laying of drainage composite foruse
Supplying for use behind walls, between
two different
two fills, alongside
different fills, alongside drains
drains of
of road,
road, below
below concrete
concrete lining of canals
lining of canals
etc. Geocomposite for for planar drainage, realized by by thermobonding aa
draining
draining corecore in extruded monofilaments
in extruded monofilaments with with two
two filtering
filtering nonwoven
nonwoven
geotextiles that may may also be be working as separation or protecting layers.
The draining
The draining three
three dimensional
dimensional core
core will
will have
haveaa “W”“W” configuration
configuration as as
longitudinal parallel channels. Minimum thickness to be
longitudinal be 7.2 mm,mm, with twotwo
filtering UV
filtering UV stabilized
stabilized polypropylene
polypropylene nonwoven geotextile of
nonwoven geotextile of minimum
minimum
thickness of
thickness of 0.75
0.75 mm charecteristic opening
mm charecteristic opening sizesize (O90)
(090) of of 110
110 micron
micron
and tensile strength of 8.0 kN/m that will be
and be working as separation or
protecting
protecting layer, geocomposite having
layer, geocomposite having in in plane flow capacity
plane flow capacity of 2.1 L//
of 2.1L
(m.s)
(m.s) at at hydraulic gradient of
hydraulic gradient of 1.0
1.0&& 20
20 kPa
kPa pressure
pressure and tensile strength
and tensile strength
18 kN/m
of 18 kN/m,, with mass per perunit
unit area ofof 740
740 gsm, supplied in the the form ofof
roll for easy
roll for easy transportation
transportation to to site
site of work as
of work as per detailed specification
perdetailed specification allall
complete as per directions of Engineer in charge. sqm
sqm 986.95
26.17 Supplying&& laying of drainage composite foruse
Supplying for use behind walls, between
two different
two fills, alongside
different fills, alongside drains
drains of
of road,
road, below
below concrete
concrete lining of canals
lining of canals
etc. having thermobondinga
thermobonding a draining core - HDPE geonet comprises
of two sets of parallel overlayed ribs integrally connected to
of haveaa
to have
rhomboidal
rhomboidal shapeshape witha with a polyethylene
polyethylene filmfilm and
and a a nonwoven geotextile
nonwoven geotextile
having mass per perunit
unit area 130 gsm
gsm andand tensile strength of 8.0 kN/m that
will be
be working as separation or protecting layer, geocomposite having in
plane flow capacity
plane flow capacity of of 0.7
0.7LL// (m.s)
(m.s) atat hydraulic gradient of
hydraulic gradient of 1.0
1.0&& 2020 kPa
kPa
pressure and and tensile strength of 13.5 kN/m kN/m,, with mass per perunit
unit area ofof
830 gsm, at
830 at easily accessible location including top and bottom, with all
top and
leads andand lifts, manpower and machinery, materials, materials, labour etc. complete
and as directed by
and by Engineer - In - Charge. sqm
sqm 1166.95
26.18 Supplying
Supplying and
and laying
laying high strength flexible
high strength flexible geogrids
geogrids (HSFG)
(HSFG) as soil
as soil
reinforcement// basal reinforcement as
reinforcement as per MORTH 3100 and IRC 113,
made of of high tenacity polyester core with polyethylene coating with
Minimum
Minimum Long Term Design
Long Term Design Strength
Strength (LTDS) of more than
(LTDS) ofmore than 50%
50% ofultimate
of ultimate
tensile strength
tensile strength at
at 30 degree Celcius
30 degree corresponding to
Celcius corresponding to 12
12 % strain .
% strain.
26.18.1
26.18.1 Ultimate tensile strength-
Ultimate tensile strength- 100
100 kN/m
kN/m sqm
sqm 393.85
26.18.2 Ultimate tensile strength-
Ultimate tensile strength- 150
150 kN/m
kN/m sqm
sqm 411.10
26.18.3 Ultimate tensile strength-
Ultimate tensile strength- 200
200 kN/m
kN/m sqm
sqm 645.80
26.18.4 Ultimate tensile strength-
Ultimate tensile 250 kN/m
strength-250 kN/m sqm
sqm 663.05
26.18.5 Ultimate tensile strength-
Ultimate tensile strength- 300
300 kN/m
kN/m sqm
sqm 681.80
26.18.6 Ultimate tensile strength-
Ultimate tensile strength- 350
350 kN/m
kN/m sqm
sqm 699.05
26.18.7 Ultimate tensile strength-
Ultimate tensile strength- 400
400 kN/m
kN/m sqm
sqm 843.00
26.18.8 Ultimate tensile strength-
Ultimate tensile strength- 500
500 kN/m
kN/m sqm
sqm 933.75
26.18.9 Ultimate tensile strength-
Ultimate tensile strength- 600
600 kN/m
kN/m sqm
sqm 1022.95
26.18.10 Ultimate tensile strength-
Ultimate tensile strength- 700
700 kN/m
kN/m sqm
sqm 1202.90
26.18.11
26.18.11 Ultimate tensile strength-
Ultimate tensile strength- 800
800 kN/m
kN/m sqm
sqm 1337.50
26.18.12 Ultimate tensile strength-
Ultimate tensile strength- 900
900 kN/m
kN/m sqm
sqm 1562.85

358
358 SUB HEAD:: 26.0 NEW
SUB NEW TECHNOLOGIES AND
AND MATERIAL•S
MATERIALS
Code No Description Unit Rate
26.18.13 Ultimate tensile strength-
Ultimate tensile strength- 1000
1000 kN/m
kN/m sqm
sqm 1742.80
26.18.14 Ultimate tensile strength-
Ultimate tensile strength- 1100
1100 kN/m
kN/m sqm
sqm 1833.60
26.18.15 Ultimate tensile strength-
Ultimate tensile strength- 1200
1200 kN/m
kN/m sqm
sqm 1922.80
26.19 Providing
Providing at all heights,
at all heights, levels and locations
levels and Aluminium profile
locations Aluminium profile industrial
industrial
troughed sheet of of Alloy 31500/31000/40800, conforming to to IS 1254, IS
737,
737, IS
IS 2676. The sheet
2676. The shall be
sheet shall fixed using
be fixed using self
self drilling/self tapping SS
drilling/self tapping SS
ofsize
screws of size 5.5x65 mmmm with EPDM seal complete upto required pitch in
horizontal, vertical or
horizontal, or curved surfaces including cutting to size and and shape
where required
where required asas per specifications, detail
per specifications, drawings and
detail drawings direction of
and direction of
Engineer-in-Charge. The be inclusive of all screws, seal, ridge,
The rate shall be
labour, scaffolding, machinery
labour, scaffolding, for fixing
machinery for fixing and
and approved
approved sealent where
sealent where
but excluding the cost of
required etc. but of purlins, rafters and
and trusses.
26.19.1
26.19.1 0.71 mm
0.71 thick, the
mm thick, the profile detail width
profile detail width 1044/920
1044/920 mm, cover
mm, cover
width 1000/875 mm.
mm. sqm
sqm 1153.95
26.19.2 0.91 mm
0.91 thick, the
mm thick, the profile detail width
profile detail width 1044/920
1044/920 mm, cover
mm, cover
width 1000/875 mm.
mm. sqm
sqm 1462.90
26.22 Providing
Providing andand fixing
fixing false
false ceiling
ceiling atat all
all heights with integral
heights with densified
integral densified
calcium silicate reinforced
calcium silicate reinforced with with fibre
fibre and
and natural filler false
natural filler false ceiling tiles of
ceiling tiles of
Size 595x595 mm mm ofapproved
of approved texture,
texture, design andand patterns as as per CPWD
Specification 2019, to
Specification 2019, to be
be laid
laid in true horizontal
in true horizontal level
level suspended
suspended on on inter-
inter-
locking metal T-Grid of hot dipped galvanised iron section of 0.33 mm mm thick
(galvanized
(galvanized@@ 120 grams per
120 grams per sqmsqm including
including both sides)comprising
both sides)comprising
of main-T runners of
of of size 24x38 mm mm ofoflength
length 3000 mm,cross - -TT ofsize
of size
24x32 mmmm oflength
of length 1200 mm mm and secondaryintermediate cross-T of of size
24x32 mm mm of of length 600
600 mm mm to formgrid module of 600 xx 600
of size 600 600 mm,mm,
suspended from ceiling using galvanised mild steel items (galvanizing (galvanizing@@
80 grams per
80 grams sqm) i.e.
per sqm) i.e. 12x50
12x50 mm mm long
long dash fasteners,66 mm
dash fasteners, mm diadia fully
fully
threaded hanger rod rod upto 1000 mm mm length and and L-shape level adjuster of
size
size 76x25x25x1.6
76x25x25x1.6 mm fixed with
mm fixed with grid andZZ cleat
grid and cleat of of size 25x37x25x1.6
size 25x37x25x1.6
mm thick with
mm thick with precut
precut hole
hole on on both
both 2525 mm flange to
mm flange to pierce
pierce into
into 12x50
12x50 mm mm
or even bigger
or even bigger sizesize dash
dash fastener
fastener ifif require, fixed with
require, fixed with Glavanised
Glavanised iron iron
perimeter wall angle or size 24x24x0.40 mm mm ofof length 3000 mm mm to to be
fixed on
fixed on periphey
periphey wall/wall / partition
partition withwith the
the help of plastic
help of plastic rawl
rawl plugs
plugs at 450
at 450
mm center to center and
mm and 40 40 mmmm long dry wall S.S S.S screws. The The work shall
be
be carried
carried out
out as
as per specifications, drawing
per specifications, drawing andand as as per directionsof the
per directionsof the
Engineer-in-Charge.
26.22.1
26.22.1 With 15 mm
mm thick Tegular edged light weight calcium sliciate false ceiling
tiles sqm
sqm 2207.00
26.22.2 With 15 mmmm thick tegular/butt edged without perforation plain/designer
light weight calcium silicate Anti-Microbial Bio-Safe coated false ceiling
tiles Confirming
tiles to JIS-Z2801
Confirming to JIS-Z2801 and
and ASTM
ASTM G-21
G-21 sqm
sqm 2301.10
26.23 Providing
Providing andand fixing
fixing false
false ceiling at all
ceiling at all heights with integral
heights with integral densified
densified
calcium silicate reinforced
calcium silicate with fibre
reinforced with fibre and
and natural filler false
natural filler false ceiling tiles of
ceiling tiles of
Size 595x595 mm mm ofapproved
of approved texture, design and and patterns having NRC NRC
(Noise
(Noise Reduction
Reduction coefficient) of 0.50
coefficient) of 0.50 (minimum)
(minimum) as as per
per IS
IS 8225:1987,
8225:1987,
Light
Light reflectance
reflectance of of 85%
85% (minimum).
(minimum). Non combustible as
Non combustible as per
per BS:476
BS:476
(part-4), fire performance
(part-4), fire performance as as per
per BS:476
BS:476 (part
(part66 &7),
&7), humidity
humidity resistance
resistance
of
of 100%, thermal conductivity
100%, thermal conductivity<< 0.043
0.043 W/mW/mKK as as per ASTM 518:1991,
per ASTM 518:1991,
in true horizontal level suspended on inter-locking metal powder coated
T-Grid of hot dipped galvanised iron section of 0.40 mm mm thick on on Silhouette
profile,rotary stiched double
profiIe,rotary stiched double webbed
webbed white
white with6
with 6 mm
mm reveal
reveal profile
profile (white/
(white/
black),comprising
bIack),comprising of of main-T
main-T runners
runners of of size
size 15x42
15x42 mm mm ofof length 3000
length 3000
mm, cross -T- T of
mm, of size 15x42 mm mm oflength
of length 1200 mm mm and secondary

SUB HEAD:
SUB HEAD : 26.0 NEW
NEW TECHNOLOGIES AND
AND MATERIALS 359
Code No Description Unit Rate
intermediate cross-T of of size 15x42 mmmm of 600 mm
of length 600 mm to form grid
module ofsize 600 xx 600
of size 600 mm, suspended from ceiling using galvanised
600 mm,
mild
mild steel
steel items
items (galvanizing
(galvanizing@@ 80 80 grams
grams per sqm) i.e.
per sqm) i.e. 50
50 mm
mm long,
long,88
mm outer diameter M-6
mm M-6 dash fasteners,6 mm dia fully threaded hanger
fasteners, 6 mm
rod upto 1000 mm
rod mm length and and L-shape level adjuster of size 85x25x2
mm. Galvanised iron perimeter wall angle of
mm. of size 22x19x0.40 mm mm of of
length
length 3000
3000 mm
mm toto be fixed on
be fixed on periphery wall / partition
periphery wall/ with the
partition with the help of
help of
plastic rawl plugs at 450
450 mmmm center to center and
and 40 mm long dry wall S.S
40 mm S.S
screws. The work
screws. The work shall
shall be carried out
be carried out as
as per specifications, drawing
per specifications, drawing and
and
as per directions of the
the Engineer-in-Charge.
26.23.1
26.23.1 With 15
With 15 mm thick integral
mm thick integral densified
densified micro
micro edge edge light weight
light weight
calcium silicate false ceiling tiles sqm
sqm 2630.40
26.24 Providing
Providing and fixing in
and fixing in position wall panelling
position wall panelling at at all
all heights
heights with with integral
integral
densified
densified calcium silicate panels/tiles
calcium silicate panels/tiles of of size
size 595
595 xx 595 595 mm,mm, having
having NRC NRC
(Noise
(Noise Reduction
Reduction coefficient)
coefficient) of of 0.50
0.50 (minimum)
(minimum) as as perper ISIS 8225:1987,
8225:1987,
Light
Light reflectance
reflectance of of 85%
85% (minimum).
(minimum). Non combustible as
Non combustible as per
per BS:476
BS:476
(part-4), fire performance
(part-4), fire performance as as per
per BS:476
BS:476 (part(part6 6 &7),
&7), humidity
humidity resistance
resistance
of
of 100%, thermal conductivity
100%, thermal conductivity <0.043<0.043 W/m W/m KK as as per ASTM 518:1991,
per ASTM 518:1991,
comprising ofa of a frame made from especially fabricated galvanised mild
steel sheet 0.50 mm mm thick pressed section (galvanizing (galvanizing @120 grams per per
sqm
sqm including
including both sides) i.e.vertical
both sides) i.e.vertical studs
studs of of size
size 48 48xx 34 34xx 3636 mm mm are are
placed
placed at at 600
600 mm centre to
mm centre to centre
centre in ina a floor
floor and ceiling channel
and ceiling channel section
section
of
of size
size 5050xx 3232 mm fixed to
mm fixed to the
the floor
floor and
and soffit at 600
soffit at 600 mm mm centre
centre using
using 12 12
mm dia,50 mm
mm mm long wedge type expanded zinc alloy dash fastner with
10
10 mm
mm bolt. This same
bolt. This same channel
channel is then to
is then to be fixed in
be fixed in horiziontal direction
horiziontal direction
at 600
600 mm mm centre to centre so as to forma
so as form a grid of 600 600 mm mm x x 600600 mm.mm.
Glasswool
Glasswool of50 of 50 mm thickness is
mm thickness then to
is then to be
be inserted
inserted in the slots
in the slots and finally
and finally
calcium silicate non
calcium silicate combustible panels/tiles
non combustible panels/tiles are are to to bebe screw
screw fixedfixed with
with
self tapping pan pan head nickel coated mild steel screws of of size 13 13 xx 3.2
mm on
mm on to this grid leaving an an even groove of of11 mmmm between the the panels.
The joints
The joints between
between the the panels
panels are are toto be duly jointed
be duly jointed and finished using
and finished using
recommended
recommended jointing jointing calcium silicate based
calcium silicate based compound
compound and fiber joint
and fiber joint
tape roll
tape roll 50
50 mm wide (90
mm wide (90 metre
metre )roll and two
)roII and two coats
coats of of primer
primer suitable
suitable for for
panelling
panelling as as per
per manufacturer’s
manufacturer's specification
specification as as per
per direction
direction of of Engineer-
Engineer-
in-Charge all complete.
26.24.1
26.24.1 With 15 mm mm thick fully perforated square/butt edge light
weight calcium silicate panels/ tiles sqm
sqm 3117.60
26.25 Providing
Providing and fixing 15
and fixing 15 mm thick false
mm thick false ceiling
ceiling tiles
tiles at at all
all heights
heights with with
integral
integral densified
densified calcium
calcium silicate
silicate reinforced
reinforced with with fibre
fibre andand natural filler
natural filler
false ceiling tiles of of Size 595x595 mm mm of of approved texture, design and and
patterns
patterns having
having NRCNRC (Noise
(Noise Reduction coefficient) of
Reduction coefficient) of 0.50
0.50 (minimum)
(minimum) as as
per
per IS 8225:1987, Light
IS 8225:1987, Light reflectance
reflectance of of 85%
85% (minimum).
(minimum). Non Non combustible
combustible
as
as per
per BS:476
BS:476 (part-4), fire performance
(part-4), fire performance as as per
per BS:476
BS:476 (part (part6 6 &7), &7),
humidity
humidity resistance
resistance of of 100%, thermal conductivity
100%, thermal conductivity << 0.043 0.043 W/m W/m KK as as
per ASTM 518:1991,
518:1991,in in true horizontal level on on the
the existing frame work
consisting
consisting of of T-sections
T-sections and and Lsections suitably fixed
Lsections suitably fixed according
according to to tile
tile size
size
as per direction of Engineer-in-charge.
as sqm
sqm 1781.20
26.26 Providing
Providing && fixing
fixing false
false ceiling
ceiling at
at all
all heights with GRG
heights with GRG (Glass
(Glass Fibre
Fibre
Reinforced
Reinforced Gypsum)
Gypsum) falsefalse ceiling tiles of
ceiling tiles of Size
Size 595x595
595x595 mm of approved
mm ofapproved
texture, design
texture, design andand patterns
patterns having
having moisture
moisture content
content less than 2%,
less than 2%,
humidity
humidity resistance
resistance of of 99%,
99%, NRC0.50 to 0.75 as
NRC0.50 to0.75 as per
per IS
IS 8225:1987,
8225:1987, NonNon
combustible
combustible asas per
per BS 476 (part
BS 476 4)-1970 and
(part 4)-1970 and light
light reflectance
reflectance ofof 85%
85%
(minimum)
(minimum) toto be
be laid
laid in true horizontal
in true horizontal level suspended on
level suspended on inter-locking
inter-locking
metal T-Grid of hot dipped galvanised iron section of 0.33 mm mm thick

360
360 SUB HEAD:: 26.0 NEW
SUB NEW TECHNOLOGIES AND
AND MATERIAL.S
MATERIALS
Code No Description Unit Rate
(galvanized
(galvanized @@ 120120 gram
gram perper sqm
sqm including
including both sides) comprising
both sides) comprising of of
main-T runners of of size 15x32 mmmm ofof length 3000 mm,
mm, cross -T- T of
of size
mm oflength
15x32 mm of length 1200 mm mm and secondary intermediate cross-T of of size
mm of
15x32 mm 600 mm
of length 600 mm to form grid module ofsize
of size 600
600xx 600
600 mm,
mm,
suspended from ceiling using galvanised mild steel items (galvanizing
@@ 80
80 grams
grams per
per sqm)
sqm) i.e.
i.e. 50
50 mm
mm long,
long,88 mm outer diameter
mm outer diameter M-6 dash
M-6 dash
fasteners,6 mm dia fully threaded hanger rod
fasteners, 6 mm rod upto 1000 mmmm length and and
L-shape level adjuster of size 85x25x2 mm. mm. Galvanised iron perimeter
wall angle
wall angle ofof size 24x24x0.40 mm
size 24x24x0.40 of length
mm of length 3000
3000 mm to be
mm to fixed on
be fixed on
periphery wall/ partition with the help of plastic rawl plugs at
wall / partition at 450
450 mm mm
center to center andand 40 mm long dry wall wood screws. The
40 mm The work shall
be
be carried out as
carried out as per
per specifications, drawing and
specifications, drawing and as
as per directions of
per directions the
of the
Engineer-in-Charge.
26.26.1
26.26.1 With semi perforated 12 12 mmmm thick micro tegular edged GRG GRG
false ceiling tiles. sqm
sqm 1852.05
26.26.2 With fully perforated 12 12 mmmm thick micro tegular edged or or 10
mm thick square edged GRG
mm GRG false ceiling tiles. sqm
sqm 1907.35
26.27 Providing
Providing andand fixing
fixing mineral fibre false
mineral fibre false ceiling tiles at
ceiling tiles at all
all heights
heights of of size
size
595X595 mm mm ofapproved
of approved texture, design and and pattern. The The tiles should
have
have Humidity
Humidity Resistance
Resistance (RH) of 99%, Light
(RH) of99%, Light Reflectance
Reflectance*≥ 85%, Thermal
85%, Thermal
Conductivitykk =
Conductivity = 0.052 - 0.057 w/m w/m K, Fire Performance as per per (BS
(BS 476
476
pt - 6 &7)in
pt-6 true horizontal
&7)in true horizontal level suspended on
level suspended on interlocking T-Grid of
interlocking T-Grid of hot
hot
dipped all round galvanized iron section of 0.33 mm mm thick (galvanized
(galvanized
@120
@120 gsm)gsm) comprising
comprising of of main
mainTT runners
runners of of 15x32
15x32 mm mm of of length 3000
length 3000
mm, crossT
mm, cross T of of size 15x32 mm mm of of length 1200 mm mm and secondary
intermediate crosscrossTT of of size 15x32 mm mm of 600 mm
of length 600 mm to form grid
module of of size 600x600 mm mm suspended from ceiling using galvanized
mild steel item
mild steel item (galvanised@80gsm)
(galvanised@80gsm) 50 50 mmmm long
long88 mmmm outer diameter
outer diameter
M-6 dash fasteners,6
M-6 fasteners, 6 mm mm diameter fully threaded hanger rod rod up to to 1000
mm length and
mm and L-shape level adjuster of size 85x25x2 mm, mm, spaced at at
1200 mmmm centre to centre along main ‘T’. The The system should rest on on
periphery walls /partitions with the help of GI GI perimeter wall angle of of
size24x24X3000
size24x24X3000 mm mm made
made of 0.40 mm
of0.40 thick sheet,
mm thick sheet, to
to be fixed to
be fixed to the
the wall
wall
with help of plastic rawl plug at 450 450 mm mm centre to centre&
centre & 40 40 mm mm long
dry wall S.S. screws. The The exposed bottom portion of all T-sections used
in false ceiling support system shall be be pre-painted with polyester baked
paint, for all
paint, for all heights. The work
heights. The work shall
shall be carried out
be carried out as
as per specifications,
per specifications,
drawings andand as per directions of the the engineer-in-charge.
26.27.1
26.27.1 With 16
With 16 mm thick beveled
mm thick tegular mineral
beveled tegular fibre false
mineral fibre false ceiling
ceiling
tile (NRC
tile (NRC 0.55 to 0.60)
0.55 to 0.60) sqm
sqm 2333.60
26.27.2 With 20
With 20 mm thick beveled
mm thick tegular mineral
beveled tegular fibre false
mineral fibre false ceiling
ceiling
tile (NRC
tile (NRC 0.7)
0.7) sqm
sqm 2671.20
26.27.3 With 16
With 16 mm thick beveled
mm thick tegular mineral
beveled tegular fibre Anti-
mineral fibre Anti-
microbial false ceiling
microbial false tile confirming
ceiling tile confirming to to ISO
ISO 55 (class
(class 100100 ))
specifications
specifications sqm
sqm 2447.15
REPAIR AND AND REHABILITATION ITEMS
26.28 Chipping of of unsound/weak concrete material from slabs, beams, columns
etc. with manual Chisel and/ or by standard power driven percussion
type or ofof approved make including tapering of all edges, making square
shoulders of of cavities including cleaning the exposed concrete surface and and
reinforcement with wire brushes etc. and and disposal of debris for for all lead
and lifts all complete as per direction of Engineer-In-Charge
and
26.28.1
26.28.1 75
75 mmmm average thickness sqm
sqm 378.00

SUB HEAD:: 26.0 NEW


SUB TECHNOL•OGIES AND
NEW TECHNOLOGIES AND MATERIALS 361
Code No Description Unit Rate
26.28.2 50 mm average thickness
50 mm sqm
sqm 256.35
26.28.3 25 mm average thickness
25 mm sqm
sqm 126.75
26.29 Cleaning of of reinforcement from rust from the the reinforcing bars toto give itita a
total rust free steel surface by using alkaline chemical rust remover of of
approved make with paint brush and and removing loose particles after 24 24
hours of
of its application with wire brush andand thoroughly washing with water
and allowing it toto dry, all complete as per direction of Engineer-In-Charge.
and
26.29.1
26.29.1 Bars upto 12 mm mm diameter metre 8.25
26.29.2 Bars above 12 mm mm diameter metre 16.45
26.30 Drilling suitable holes in reinforced or plain cement concrete with power
driven drill machine to toaa minimum depth of 100 mm
of 100 mm upto 200
200 mmmm in RCC
RCC
lintels, columns and slabs to introduce steel bars forsunshades/
beams, lintels, for sunshades/
balconies
balconies including fixing the
including fixing the steel
steel bars
bars in
in position
position using
using epoxy
epoxy resin
resin
anchor grout of approved make but butexcluding
excluding the cost of reinforcement,
all complete as per direction of Engineer-In-Charge.
26.30.1
26.30.1 Upto
Upto and
and including
including 12
12 mm
mm dia.
dia. each 141.20
26.31
26.31 Providing, mixing and
Providing, and applying bonding coat of of approved adhesive on on
chipped
chipped portion of RCC
portion of RCC as as per specifications and
per specifications and direction
direction of
of Engineer-
Engineer-
In-charge complete in all respect.
26.31.1
26.31.1 SBR Polymer
SBR Polymer (@10%(@10% of of cement
cement weight)
weight) modified
modified
cementitious bond coat@
coat @ 2.2 kg cement per persqm
sqm ofsurface
of surface
area mixed
area with specified
mixed with specified proportion of approved
proportion of approved polymer
polymer sqm
sqm 141.20
26.31.2 Epoxy bonding adhesive having coverage 2.20 sqm/kg of of
approved make sqm
sqm 285.20
26.32 Providing,
Providing, mixing and applying
mixing and applying SBR
SBR polymer
polymer (of approved make)
(ofapproved make) modified
modified
Cement mortar in proportion of 1:4 (1 (1 cement:
cement:44 graded coarse sand with
polymer
polymer minimum
minimum 2% 2% by wt. of cement used)
by wt.ofcement used) asas per specifications and
per specifications and
directions of Engineer-in-charge.
Note: Measurement and payment: The The pre-measurement of of thickness
be done just after the
shall be the surface preparation is completed and and Payment
under this item shall be
be made only after proper wet wet curing has
has been done
and surface has
has been satisfactorily evaluated by sounding
sounding// tapping with
aa blunt metal instrument and/or the 75 75 mm
mm size cube crushing strength at
the end
the end of
of 28
28 days
days tobe
to be not less than
notless than 30
30 N/Sqmm2).
N/Sqmm2).
26.32.1
26.32.1 12 mm
12 mm average thickness. sqm
sqm 388.65
26.32.2 25 mm average thickness in
25 mm in2 2 layers. sqm
sqm 587.35
26.32.3 50 mm average thickness in
50 mm in3 3 layers. sqm
sqm 1174.70
26.33 Providing, mixing and
Providing, and applying SBR
SBR polymer (of (of approved make @@
minimum
minimum 2% 2% by wt. of cement
by wt.of cement used)
used) modified
modified plain/reinforced
plain/reinforced cement
cement
concrete forfor structural members having minimum characteristic
compressive strength [with ordinary portland cement, coarse sand and
graded stone aggregate of mm maximum size in proportion as
of 10 mm as per
per
design criteria]
design with specified
criteria] with specified average thickness.
average thickness.
Note:
Note: Rates shall be
Rates shall for finished
be for finished surface
surface area of concrete and
area ofconcrete shall include
and shall include
the cost of labour, concrete and and appropriate approved Super-Plasticiser
for rendering
for concrete as
rendering concrete flowable and
as flowable and SBR
SBR polymer
polymer but shall exclude
but shall exclude
cost of reinforcement, bond coat, Shear Keys, centering and and shuttering,
strutting, etc (Payment under this item shall be
strutting, propping etc be made only after
proper wet
wet curing hashas been done and surface has has been satisfactorily
evaluated by
evaluated sounding/tapping witha
by sounding/tapping with a blunt
blunt metal
metal instrument)
instrument)

362
362 SUB HEAD:: 26.0 NEW
SUB NEW TECHNOLOGIES AND
AND MATERIAL•S
MATERIALS
Code No Description Unit Rate
26.33.1
26.33.1 50 mm thick in Grade M25
50 mm M25 with cement content not less
than 330
330 kg per cum
cum sqm
sqm 569.15
26.33.2 75 mm thick in Grade M25
75 mm M25 with cement content not less
than 330
330 kg per cum
cum sqm
sqm 853.70
26.34 Providing
Providing andand laying
laying SBR
SBR Polymer
Polymer modified
modified (of (of approved
approved make
make @@
minimum
minimum 2% 2% by wt. of cement
by wt.of cement used)
used) plain/reinforced
plain/reinforced concrete jacket
concrete jacket
for
for the structural members e.g. columns, pillars, pillars, piers, beams etcwith
etc with
concrete
concrete having
having thethe specified
specified minimum characteristic compressive
minimum characteristic compressive
strength [with ordinary portland cement, coarse sand and graded stone
aggregate of mm maximum size in proportion as
of 10 mm per design criteria]
as per
with specified
with specified average
average thickness
thickness all-round
all-round existing
existing core of RCC
core of RCC member.
member.
Note:
Note: Rates
Rates shall
shall be for finished
be for finished surface
surface area
area ofof concrete
concrete andand shall
shall
include the cost of making holes in existing RCC RCC slab, if required, for
pouring concrete in shuttering mould ofjacket and appropriate approved
of jacket and
Super-Plasticiser
Super-Plasticiser forfor rendering
rendering concrete
concrete as flowable self
as flowable self compacting
compacting and and
SBR polymer but
SBR but shall exclude cost of reinforcement, bond coat, Shear
Keys, centering and and shuttering, strutting, propping etc (Payment under
this item shall be
be made only after proper wet wet curing hashas been done and
has been satisfactorily evaluated by sounding/tapping witha
surface has with a blunt
metal
metal instrument)
instrument)
26.34.1
26.34.1 50 mm thick in Grade M25
50 mm M25 with cement content not less
than 330
330 kg per cum
cum sqm
sqm 569.15
26.34.2 75 mm thick in Grade M25
75 mm M25 with cement content not less
than 330
330 kg per cum
cum sqm
sqm 853.70
26.34.3 100 mm
100 mm thick in Grade M25 M25 with cement content not less
than 330
330 kg per cum
cum sqm
sqm 1138.25
26.35 Providing and
and injecting approved grout in proportion recommended by by
themanufacturer
the manufacturer into cracks/honey-comb area of of concrete/masonry by
suitable gun/pump atrequired
at required pressure including cutting of nipples after
curing etc. complete as per directions of Engineer-in-Charge.
(The payment shall be be made on on thebasis
the basis of actual weight of of approved
grout
grout injected.)
injected.)
26.35.1
26.35.1 Stirrer mixed
Stirrer Acrylic Polymer
mixed Acrylic of approved
Polymer of approved make
make@@ 2%2% of
of
weight of
weight of cement
cement used)
used) modified
modified Cement
Cement slurry
slurry made with
made with
non shrink compound in concrete/RCC work
non kg 119.30
26.35.2 Stirrer
Stirrer mixed
mixed SBR
SBR Polymer
Polymer (of approved make)
(ofapproved make) modified
modified
Cement slurry made with Shrinkage Compensating Cement
in concrete/RCC work. kg 124.00
26.35.3 Epoxy injection grout in concrete/RCC work of
of approved
make kg 553.40
26.36 Providing, erecting,
Providing, erecting, maintaining and and removing temporary protective
screens
screens made
made out of specified fabric
outofspecified fabric with
with all
all necessary fixing arrangement
necessary fixing arrangement
to
to ensure that it remains in position for the
the work duration as by
as required by
the Engineer-in-charge.
26.36.1
26.36.1 Wooven PVC
Wooven cloth
PVC cloth sqm
sqm 54.25
26.37 Cleaning of
ofexposed
exposed concrete surface of sticking material including loose
and
and foreign material by
by sand blasting with coarse sand followed by by and
and
including cleaning with oil free air blast as per direction of Engineer in
as per
charge. sqm
sqm 382.40

SUB HEAD:: 26.0 NEW


SUB TECHNOL•OGIES AND
NEW TECHNOLOGIES AND MATERIALS 363
Code No Description Unit Rate
26.38 Shotcreting R.C.C. columns, beams and andslabs
slabs etc. in layers with approved
design
design mix concrete having
mix concrete the specified
having the specified minimum
minimum characteristic
characteristic
compressive strength [with ordinary portland cement, coarse sand and
graded stone aggregate of mm maximum size in proportion as
of 10 mm as per
design criteria] including the
the cost of centering and
and shuttering at edges and
as directed by
corners etc. as by Engineer- in-Charge
Note: Rates shall include the providing necessary ground wires etc. TheThe
levelling gauges, if used, shall bebe paid for
for separately. Payment under
this item shall be
be made only after proper wet
wet curing has
has been done and
has been satisfactorily evaluated by sounding/tapping witha
surface has with a blunt
metal instrument.
26.38.1
26.38.1 25
25 mmmm thick in Grade M25 M25 with cement content not less
than 330
330 kg per cumcum sqm
sqm 746.90
26.38.2 50
50 mmmm thick in Grade M25 M25 with cement content not less
than 330
330 kg per cumcum sqm
sqm 1151.05
26.38.3 75
75 mmmm thick in Grade M25 M25 with cement content not less
than 330
330 kg per cumcum sqm
sqm 1628.85
26.39 Providing and
and inserting 12 12 mmmm diadia galvanised steel injection nipple in
honey comb area and and along crack line including drilling of of holes of required
diametre
diametre (20
(20 mm
mm toto 30
30 mm)
mm) up to depth
up to depth from
from 3030 mm to 80 mm
mm to80 at required
mm atrequired
and making thehole
spacing and the hole&& crack dust free by by blowing compressed air,
sealing the distance between injection nipple with adhesive chemical of of
approved make andallow
and allow it toto cure complete as per direction of Engineer-
In-Charge.
In-Charge. each 236.90
26.40 Providing and fixing
Providing and fixing hard drawn steel
hard drawn steel wire
wire fabric
fabric of
of size
size 75 x25 mm
75 x25 mm mesh
mesh
or other suitable
or other size wire
suitable size wire mesh
mesh to to be fixed & firmly
be fixed& firmly anchored
anchored toto the
the
concrete
concrete surface
surface byby means of “L” shaped mild
means of“L”shaped steel shear
mild steel shear key welded
key welded
with existing reinforcement including the the cost of materials,
materials, labour, tool&
tool &
plants as
as approved by Engineer-in-charge. sqm
sqm 902.55
NEW TECHNOLOGY ITEMS
NEW
26.41
26.41 Designing,
Designing, providing,
providing, installing
installing andand fixing
fixing factory
factory finished
finished custom
custom
designed cold form Light Gauge Steel Framed super structure comprising
of steel wall panel, trusses, purlins etc
of etc manufactured out out ofof minimum 0.75
mm thick steel sheet as per design requirements.
mm requirements. The The steel sheet shall
be galvanized (AZ-150gms
be galvanized Aluminium Zinc
(AZ-150gms Aluminium Zinc Alloy
Alloy coated
coated steel
steel having
having
minimum yield strength
minimum yield strength 300-550
300-550 Mpa)Mpa) conforming
conforming to to AISI
AISI specifications
specifications
and IBC
and IBC 2009 for for cold formed steel framing and and construction and and also as
as
per IS: 875-1987, ISO ISO 800-1984 and IS:801- 1975. The The wind load shall
be as per
be as per provisions of IS
provisions of IS 875
875 (part -III). LGSFS
(part -III). frame shall
LGSFS frame shall be designed
be designed
801 using commercially available software such as Frame CAD
as per IS: 801 CAD
Pro-11.7/
Pro-11.7/ STAAD
STAAD PRO-V8i/ArchitekV2.5.16/
PRO-V8i/ArchitekV2.5.16/ Revit Revit architecture-2011
architecture-2011 or or
equivalent. Proper usage of of Connection Accessories like Heavy Duty
Tension Ties, Light Duty Hold-ons,
Hold-ons, Twist Straps (to connect truss with
wall frames),
wall frames), Strong
Strong Tie,
Tie, Tie
Tie Rod,
Rod, H-Brackets,
H-Brackets, Boxing
Boxing Sections,
Sections, L-Shaped
L-Shaped
Angles forbetter
for better structural stability.
stability. The
The framing section shall be be cold form
C-type
C-type having
having minimum
minimum webweb depth
depth 89 89 mm
mm xx 3939 mm flange x 11
mm flangex 11 mm
mm lip
lip
in required length as as per structural design requirement duly punched with
dimple/slot at required locations as per approved drawings. The
as per The slots will
be along centre line of webs and
be and shall be be spaced minimum 250 mm mm away
from both ends of ofthe
the member. The The frame can be supplied in panelized
or
or knock
knock down condition in
down condition specific dimensions
in specific dimensions and fastened with
and fastened with screws
screws
extending through the steel beyond by minimum ofthree of three exposed threads.
All self drilling tapping screws forjoining
for joining thethe members shall

364
364 SUB HEAD:: 26.0 NEW
SUB NEW TECHNOLOGIES AND
AND MATERIAL.S
MATERIALS
Code No Description Unit Rate
have
haveaa Type
Type IIII coating
coating in accordance with
in accordance with ASTM
ASTM B633(13)
B633(13) or or equivalent
equivalent
corrosion protection of gauge 10 10&& 12,
12,TPI 16&&88 oflength
TPI 16 20 mm.
of length 20 mm. The
The
frames shall
frames shall be fixed to
be fixed to RCC
RCC slab or Tie
slab or Tie beam
beam over
over Neoprene
Neoprene rubber
rubber
using self expanding carbon steel anchor bolt of dia as per
dia as per approved
drawings. design subject to minimum 12 12 mm
mm diameter andand 121
121 mm
mm length
conforming toAISI
to AISI 304304 and
and 316 500 mm
316 at 500 mm c/cwith
c/c with minimum embedment
of
of 100
100 mm
mm in in RCC
RCC (RCC to be paid
(RCC tobe separately) and
paid separately) and located
located not
not more
more
than 300
300 mmmm from corners or termination of bottom tracks complete in
respects. The
all respects. The item also includes the submission of of stability reports
duly examined and issued by any any NIT/IIT. The
The rate includes the concept
design, detailed design, fabrication of sections, transportation, installation
installation
and
and all
all required fixing arrangement
required fixing arrangement at at site
site as
as described above.
described above. kg 285.90
26.42 Providing
Providing andand fixing
fixing of external wall
of external wall system
system on on Light gauge steel
Light gauge frame
steel frame
work with
work with outer
outer face
face cement
cement boardsboards as as per standard sizes
per standard sizes fixed
fixed with
with self-
self-
drilling/ / taping screws
drilling screws// fasteners@
fasteners @ 60 60 cmcm c/c of approved make. make.AA
groove of of22 mm
mm to to33 mm
mm shall be be maintained and and grooves shall be be sealed
with silicon
with silicon based sealant. The
based sealant. The board
board shall
shall be fixed in
be fixed ina a staggered
staggered pattern.
pattern.
Screws shall be be of counter sunk rib head of1.60 of 1.60 mmmm to44 mm mm thick or8or 8 to
10 gauge oflength
10 of length varying from 25 25 to45
to 45 mm mm and. Internal face 12.5 mm mm
thick gypsum
thick gypsum plaster
plaster board fixed on
board fixed on cement
cement boardboard as as per
per standard
standard sizes
sizes
fixed with
fixed with self- drilling / taping
self- drilling/ taping screws
screws// fasteners@
fasteners @ 60cm 60cm c/c of approved
cisofapproved
make,
make, proper taping and
proper taping and jointing
jointing to to be
be done
done using fiber mesh
using fiber mesh tapetape andand
epoxy
epoxy andand acrylic
acrylic based jointing compound
based jointing for seamless finish.(cost
compound forseamless finish.(cost of of
frame work
frame work tobe
to be paid for separately)
paid for separately)
26.42.1
26.42.1 Outer face-
Outer face- Outer
Outer face face having
having 66 mm mm thick thick fiber
fiber cement
cement
board
board TypeType A, A, Category-IV
Category-IV as as perper IS:14862:2000
IS:14862:2000 fixed fixed
on 99 mm
on thick fiber
mm thick fiber cement
cement board,
board, Type Type A, A, Category-IV
Category-IV
as per
as per IS:14862:2000
IS:14862:2000 (high (high pressure
pressure steam steam cured)
cured) Inner
Inner
Face- 12.5 mm mm thick gypsum plaster board conforming to to IS
2095:2011 fixed
2095:2011 fixed on on88 mm thick fibre
mm thick fibre cement
cement board board of of Type
Type
B,Category-III
B, Category-III as as per
per IS:14862:2000 (High pressure steam
cured)
cured) sqm
sqm 3580.65
26.42.1A
26.42.1 A Outer face-
Outer face- Outer
Outer face face having
having 66 mm mm thick thick fiber
fiber cement
cement
board
board TypeType A, A, Category-III
Category-III as as per
per IS:14862:2000
IS:14862:2000 fixed fixed
on 99 mm
on thick fiber
mm thick fiber cement
cement board board TypeType A, A, Category-III,
Category-III,
as per
as per IS:14862:2000
IS:14862:2000 (high (high pressure
pressure steam steam cured)
cured) Inner
Inner
Face- 12.5 mm mm thick gypsum plaster board conforming to to
IS 2095:2011 fixed
IS 2095:2011 fixed on on88 mm thick fibre
mm thick fibre cement
cement boardboard of of
Type B, B, Category-III,
Category-III, as as per
per IS:14862:2000 (High pressure
steam cured)
steam cured) sqm
sqm 2821.65
26.42.2 Outer face: Outer face having having88 mm mm thick cement bonded
particle
particle Board fixed on
Board fixed on 1010 mm thick cement
mm thick cement bondedbonded particle
particle
board.
board. (Termite,
(Termite, Fire and Moisture
Fire and Moisture Resistance)
Resistance) as as per
per IS IS
14276:1995. Inner face:-12.5 mm
14276:1995. mm thick gypsum plaster
board conforming to
board conforming to IS 2095:2011 fixed
IS 2095:2011 fixed on on 88 mm thick
mm thick
cement
cement bonded
bonded particleparticle board
board (Termite,
(Termite, fire fire and
and moisture
moisture
resistance)
resistance) confirming
confirming to to IS:14276:1995)
IS:14276:1995) sqm
sqm 3167.85
26.43 Providing and fixing
Providing and fixing internal wall panels
internal wall on Light
panels on gauge steel
Light gauge frame work
steel frame work
with 12.5
with 12.5 mm thick gypsum
mm thick gypsum plaster
plaster board
board conforming
conforming IS 2095:2011 fixed
IS 2095:2011 fixed
on cement board
on cement as per
board as standard sizes
per standard sizes fixed
fixed with
with self-drilling
self-drilling/ / taping
taping
screws// fasteners@
screws fasteners @ 60 60 cm
cm c/c of approved make, Screws shall be be of
counter sunk rib head of of 1.60 mmmm to4 mm thick or
to 4 mm or88 to 1010 gauge of of
length varying from 25 to to 45 mm. Proper taping and
45 mm. and jointing to bebe done
using fiber mesh
using fiber tape and
mesh tape and epoxy
epoxy and acrylic based
and acrylic jointing compound
based jointing compound for for
seamless finish.(cost of
seamless finish.(cost of frame
frame work
work tobe
to be paid for separately
paid for separately

SUB HEAD:: 26.0 NEW


SUB NEW TECHNOLOGIES AND
AND MATERIALS 365
Code No Description Unit Rate
26.43.1
26.43.1 Cement Fiber Board
Board88 mm
mm thick of Type B,
B, Category III asas
per
per IS
IS 14862:2000
14862:2000 (High
(High pressure
pressure Steam
Steam Cured)
Cured) sqm
sqm 2221.05
26.43.2 Cement Bonded particle board 88 mm mm (Termite,
(Termite, Fire &&
Moisture
Moisture Resistance),
Resistance), as as per
per IS:14276
IS:14276:: 1995
1995 sqm
sqm 2189.75
26.44 Providing and fixing
Providing and fixing in all exterior
in all face panels
exterior face panels breathable vapour barrier
breathable vapour barrier
underneath the cement
underneath the cement fiber
fiber board
board asas per
per National
National Building
Building Code 2009
Code 2009
complete as per direction of Engineer-in-charge. sqm
sqm 298.75
26.45 Supplying
Supplying and
and installation
installation ofof moisture
moisture resistant/fire
resistant/fire resistant
resistant cement
cement board
board
as
as per
per standard sizes fixed
standard sizes fixed with
with self-drilling/
self-drilling / taping
taping screws.
screws. Screws shall
Screws shall
be of counter sunk rib head of1.60
be mm to44 mm
of 1.60 mm mm thick or8
or 8 to 10
10 gauge of
of
length varying from 2525 to45 mm.
to 45 mm.
26.45.1
26.45.1 Cement Fiber Board Board66 mm mm thick as per IS 14862:2000 of
as per of
type B (High
typeB (High pressure
pressure Steam
Steam Cured)
Cured) sqm
sqm 1430.15
26.45.2 board88 mm
Cement Bonded particle board mm thick (Termite, Fire
Fire&&
Moisture
Moisture Resistance),
Resistance), as
as per
per IS:14276
IS:14276:: 1995
1995 sqm
sqm 991.95
26.46 Providing
Providing and fixing in
and fixing in position, 200 mm
position, 200 mm thickthick factory
factory made
made Expanded
Expanded
Polystyrene
Polystyrene Core Core (EPS(EPS Core) wall panels
Core) wall panels consisting
consisting of of EPS core
EPS core
sandwiched between two Engineered sheets of of welded wire fabric mesh
duly finished with
duly finished with shortcrete
shortcrete materials
materials onon outer
outer faces.
faces. The
The fabric
fabric mesh
mesh
be made of
shall be of33 mm
mm diaG.I.
dia G.I. wire mesh with 50 50 mm
mm pitch in both the
directions andand on on both faces of of the wall, kept at 120-135 mm mm gapgap and
and
connected by the zigzag zig zag G.I. wire of33 mm mm dia at alternate row row by
by welding
(at
(at an angle ranging
an angle ranging fromfrom 50-70 degree) . The
50-70 degree). The EPS
EPS core shall consist
core shall consist of
of
100 mm
100 mm thick EPS EPS of density not less than 20 kg/ per cum. Both the outer
20 kg/
faces of
faces of the
the panel shall be
panel shall finished by
be finished applying the
by applying the layer of 50
layer of 50 mm thick
mm thick
cement
cement mortar
mortar 1:3 {1 cement:
1:3 {1 cement:33 coarse sand (not
coarse sand (not having
having more than 40%
more than 40%
stone chips of
stone chips size upto
of size upto66 mm)}
mm))AÀ with
with the
the help
help ofof shotcreting/guniting
shotcreting/guniting
equipment
equipment etc etc atataa pressure
pressure not not less than 1 bar
less than1 bar (100Kn/m2)
(100Kn/m2) and and both
both
surfaces finished with
surfaces finished with trowel.
trowel. Fixing operations of
Fixing operations of wall
wall panels shall be
panels shall be
completed
completed in all respect
in all respect asas per drawings and
per drawings specifications and
and specifications and under the
under the
overall direction of the the Engineer-in-charge. sqm
sqm 4347.15

26.47 Providing
Providing and fixing in
and fixing in position, 230 mm
position, 230 thick factory
mm thick factory made
made Expanded
Expanded
Polystyrene
Polystyrene CoreCore (EPS
(EPS Core)
Core) roof/floor
roof/floor panels
panels mademade of of33 mm dia G.I.
mm diaG.I.
wire mesh with 50 50 mm
mm pitch in both the directions and and onon both faces of of
panel, kept at at 120-135 mm mm gapgap andand connected by the zig zig zag
zag G.I. wire
of33 mm
mm dia at alternate row row by
by welding (at (atanan angle ranging from 50-70
degree). The EPS
degree). The core shall
EPS core shall consist
consist ofof 100
100 mm thick EPS
mm thick EPS of of density
density not
not
less than 20kg/
less than 20kg/ per
per cum. The bottom
cum. The bottom side
side ofof the
the panel
panel shall
shall be finished
be finished
by applying
by applyingaa layer of 60-65 mm mm thick cement mortar 1: 1:3 3 (1
{1 cement:3
cement: 3
coarse sand (not
coarse sand (not having
having more than 40%
more than 40% stone chips of
stone chips of size
size upto
upto66 mm)}
mm)}
AA with the help of shotcreting equipment etcat etc ataa pressure of of not less than
11 bar
bar (100KN/m2)
(100KN/m2) and and surface finished with
surface finished with trowel.
trowel. The
The top top face
face of
of the
the
panel shall be
panel shall be provided
provided andand finished
finished by applying 70-75
by applying 70-75 mm thick layer
mm thick of
layer of
cement concrete 1:1.5:1:1.5:3 3 (1
(1 cement :1.5 coarse sand:3 sand : 3 graded stone
aggregate
aggregate 20 20 mmmm nominal
nominal size).
size). Fixing
Fixing operations
operations of of roof/floor
roof/floor panels
panels
shall
shall be completed in
be completed all respect
in all respect as as per drawings and
per drawings and specifications
specifications andand
under the
the overall direction of thethe Engineer-in-charge. sqm
sqm 4701.60

366
366 SUB HEAD:: 26.0 NEW
SUB NEW TECHNOLOGIES AND
AND MATERIAL•S
MATERIALS
Code No Description Unit Rate
26.48 Providing
Providing and and fixing
fixing of customized Aluminium
of customized Aluminium form form work
work formonolithic
for monolithic
construction on RCC members with repetitive usage made up
on RCC upof
of aluminium
sheets/plates
sheets/plates of of minimum
minimum44 mm thickness and
mm thickness and grade
grade 6061
6061 (Type-6).
(Type-6). TheThe
formwork comprises
formwork comprises of of (a) wall panel,
(a)wall panel, roccker,
roccker, kicker and internal
kicker and internal soffit
soffit
corner,
corner, external
external soffit
soffit corner,
corner, external
external corner,
corner, internal
internal corner
corner etc.,
etc., (b)
(b) beam
beam
components
components i.e, i.e, beam side panel,
beam side panel, propprop head for soffit beam,
head forsoffit beam, beams
beams soffit
soffit
panel,
panel, beam
beam soffit
soffit bulk
bulk head
head andand (c) deck components
(c) deck components i.e. deck panel,
i.e. deck panel,
deck
deck prop,
prop, prop
prop length, deck mid,
length, deck mid, soffit
soffit length, deck beam
length, deck beam bar. The panels
bar. The panels
are held in position by byaa simple pin pinandand wedge system that passes thorugh
holes
holes in the out
in the out side
side rib of each
rib of each panel.
panel. TheThe tolerance
tolerance of of finished
finished panel
panel shall
shall
not
not be
be less than (-1
less than (-1 mm)
mm) and shall conform
and shall conform to to IS
IS:: 14987-1999.
14987-1999. Pins and
Pins and
wedges tobe to be made ofhighof high grade hot hot dipped galvansied mild steel. This
form work
form work also comprises of
also comprises of M.S.
M.S. angleangle iron, “Z” shaped
iron, “Z” shaped brackets
brackets braced
braced
diagonally at 0.90 to to 1.00 metre centre to centre on on extrenal wall face
just the
just the level
level below
below on which to
on which to lay M.S. square
layM.S. square tubetube panels
panels (Challis) and
(Challis) and
guard railing supports to form working platform and and 4040 mmmm dia G.I./M.S.
G. I./M.S.
telescopic adjustable
telescopic adjustable props
props to to support
support deck formwork and
deck formwork and beam soffit
beam soffit
panels including de-shuttering the formwork from odd/even level to be be
shifted/lifted to next alterante odd/even level before which the the points andand
shuttering surface to be be thoroughly cleaned, pins greasing and and shuttering
surface oiling propoerly
surface oiling propoerly before fixing all
before fixing all complete
complete including
including sealing of gap
sealing of gap
between
between kicker
kicker plates
plates ofof wall
wall panel
panel and and floors
floors (if
(if any)
any) asas per design of
per design of
formwork as provided by shuttering supplier and and asas per direction of the the
Engineer-in-charge
Engineer-in-charge including filling and
including filling and finishing
finishing thethe holes
holes of of varied
varied sizes
sizes
and shapes (left by
and by keys/pins of aluminium form work shuttering while de-
shuttering)
shuttering) withwith GP-2
GP-2 cementitious
cementitious polymer compound mixed
polymer compound with water
mixed with water
in ratio prescribed by by manufacturer to to form consistent workable enough
forpushing
for pushing it in the the holes upto full depth of of wall using appropriate tools
and finishing smooth
and finishing smooth all complete as
all complete as per directions of
per directions of the
the Engineer-in-
Engineer-in-
charge. sqm
sqm 451.35
26.49 Providing
Providing and fixing in
and fixing in position factory made
position factory made EPSEPS cement
cement sandwich
sandwich wall/ wall/
roof/floor
roof/floor light weight solid
light weight solid core
core panels
panels made of core material
made ofcore material of of EPS
EPS
granule balls/beads (conforming to IS 4671:1984 and shall have density
not
not less than 15kg
less than 15kg perper cum) adhesive, cement,
cum) adhesive, cement, sand, flyash and
sand, flyash and other
other
bonding material in mortar state processed toform to form in ina a preset mould. The The
outer face on
outer face on both
both sides
sides ofof the
the panels will be
panels will be non asbestos fiber
non asbestos fiber cement
cement
board confirming to
board confirming to IS
IS 14862:2000
14862:2000 or or Calcium silicate board
Calcium silicate board confirming
confirming
to EN
EN 14306:2009 of of55 mm
mm thick each. Panel shall be be laid on on 6 6 mm
mm thick
cement
cement mortar
mortar (1 cement: 2 fine
(1 cement:2 fine sand)
sand) mixed with chemical
mixed with chemical adhesive
adhesive of of
0.5
0.5 kg
kg perper 50
50 kg of cement
kg of cement or or shall
shall be
be preferably fixed into
preferably fixed into ‘C’
‘C’ channel
channel
made of1.2mm
of 1.2 mm thick MS MS plate screwed/fastenened to to the slab/column/
beam
beam etc. The panel
etc. The shall fixed
panel shall fixed vertically
vertically with
with tongue
tongue and groove joint
and groove joint
and
and horizontally
horizontally locked
locked withwith steel
steel bar
bar between
between each other and
each other and floors
floors
and filled with
and filled with cement
cement mortar
mortar andand adhesive.
adhesive. Panels
Panels should
should be be used
used as as
floor & roofing
floor& with additional
roofing with additional structural
structural support,
support, steel
steel or or RCC depending
RCC depending
upon thedesign.
the design. All thethe operation shall be be completed in all respect as as per
drawings,
drawings, Manufacturers
Manufacturers specifications
specifications and and under
under the the overall
overall direction
direction
of
of Engineer-in-Charge
Engineer-in-Charge (Cost (Cost of all the
of all the material
material is is included except “C
included except “C
channel”
channel” whichwhich will
will be
be paid
paid seperately).
seperately).
26.49.1
26.49.1 Non load bearing panels 50
Non 50 mm
mm thick of required size sqm
sqm 1315.70
26.49.2 Non load bearing panels 60
Non mm thick of required size
60 mm sqm
sqm 1487.50
26.49.3 Non load bearing panels 75
Non mm thick of required size
75 mm sqm
sqm 1840.05
26.49.4 Non load bearing panels 90
Non mm thick of required size
90 mm sqm
sqm 2141.80
26.49.5 Non load bearing panels 100
Non 100 mm
mm thick of required size sqm
sqm 2518.20

SUB HEAD:: 26.0 NEW


SUB NEW TECHNOLOGIES AND
AND MATERIALS 367
Code No Description Unit Rate
26.50 Providing
Providing and and fixing
fixing in
in position factory made
position factory made non asbestos fibre
nonasbestos fibre reinforced
reinforced
aerated cement sandwich
aerated cement sandwich wall/roof/floor
wall/roof/floor light weight solid
light weight core panels
solid core panels
made oflight
of light weight cement concrete core composed of ofOPCOPC cement,
pulverized flyash, quick
pulverized flyash, quick lime, cotton pulp
lime, cotton pulp && Gypsum
Gypsum in in mortar state
mortar state
mixed with aeration agent in ina a preset mould. The The outer face on on both
sides
sides of the panels
of the will be
panels will be non
non asbestos fibre cement
asbestos fibre cement board
board confirming
confirming to to
:14862:2000. These solid wall panels are installed using Galvanized iron
IS :14862:2000.
steel tracks/C channel of1 of 1 mmmm thick of required sizes as as recommended
by
by manufacturer’s
manufacturer's and and fixed
fixed toto floor
floor and
and RCCRCC soffit
soffit in
in plumb
plumb to to each
each
other with steel
other with steel screw/fasteners.
screw/fasteners. The The panel
panel shall
shall be fixed vertically
be fixed vertically with
with
tongue && groove
tongue groove joint
joint with
with cement
cement basedbased polymer
polymer modified jointing
modified jointing
compound.
compound. The The exposed
exposed surface
surface finished
finished with
with fibre
fibre mesh/glass
mesh/glass fibrefibre tape
tape
with polymer
with polymer based jointing compound
based jointing compound having superior flexibility.
having superior flexibility. Panels
Panels
should
should be be used
used as floor & roofing
as floor& with additional
roofing with additional structural
structural support, steel
support, steel
RCC depending upon thedesign.
or RCC the design. All thethe operation shall be be completed
in
in all
all respect
respect as as per drawings, Manufacturers
per drawings, Manufacturers specifications
specifications and and under the
under the
overall direction of Engineer-in-Charge (Cost of of all the
the material is included
except “tracks/C channel”
except “tracks/C which will
channel" which will be
be paid
paid separately).
separately).
26.50.1
26.50.1 Non load bearing panels 50
Non mm thick of required size
50 mm
(minimum
(minimum44 mm thick fibre
mm thick fibre cement
cement board Type B,
board Type B, Category
Category
III
III asas per
per IS:
IS: 14862:2000
14862:2000 on on both faces )
both faces) sqm
sqm 1527.50
26.50.1A
26.50.1 A Non load bearing panels 50
Non 50 mm
mm thick of required size
(minimum
(minimum44 mm thick fibre
mm thick fibre cement
cement board Type A,
board Type A, Category
Category
III
III asas per
per IS:
IS: 14862:2000
14862:2000 on on both faces )
both faces) sqm
sqm 1635.05
26.50.1B
26.50.1 B Non load bearing panels 50
Non mm thick of required size
50 mm
(minimum
(minimum44 mm thick fibre
mm thick fibre cement
cement board Type A,
board Type A, Category
Category
IV as per
IV as per IS:
IS: 14862:2000
14862:2000 onon both faces)
both faces) sqm
sqm 2068.25
26.50.2 Non load bearing panels 75
Non mm thick of required size
75 mm
(minimum
(minimum55 mm thick fibre
mm thick fibre cement
cement board Type B,
board Type B, Category
Category
III
III asas per
per IS:
IS: 14862:2000
14862:2000 onon both faces)
both faces) sqm
sqm 1841.20
26.50.2AA Non load bearing panels 75
Non mm thick of required size
75 mm
(minimum
(minimum55 mm thick fibre
mm thick fibre cement
cement board Type A,
board Type A, Category
Category
III
III asas per
per IS:
IS: 14862:2000
14862:2000 on on both faces)
both faces) sqm
sqm 1784.40
26.50.2BB
26.50.2 Non load bearing panels 75
Non mm thick of required size
75 mm
(minimum
(minimum55 mm thick fibre
mm thick fibre cement
cement board Type A,
board Type A, Category
Category
IV as per
IV as per IS:
IS: 14862:2000
14862:2000 onon both faces)
both faces) sqm
sqm 2326.65
26.51
26.51 Supplying of of standard quality GFRG panel of 124 mm
of 124 mm thickness with
modular cavities purchased from GFRG panel manufacturing
manufacturing plant in thethe
country, cut to
country, cut to required wall sizes
required wall and floor/
sizes and floor/ roof
roof slab
slab sizes
sizes in correct
in correct
and height, including cutting of door, window and ventilator
length and
opening as per the cutting drawing prepared by architects /design
engineers forthe
for the construction of GFRG building and and loaded in stillages
for transportation to the
the construction site. Cost of of panel includes security
deposits, hire charges ofstillages&
of stillages & jaws, cost of transportation in trucks/
lorries without any
any damages upto 300 300 km
km including all leads and
and lifts from
manufacturing plant to construction site and
GFRG manufacturing and unloading at site
using suitable fork lift/ crane. (Payment shall be be made on on thebasis
the basis of
area ofof one
one side of panel without reduction of opening of of door/ window
// ventilator).
ventilator). For transportation above
For transportation above 300
300 km,
km, additional charges to
additional charges to be
be
paid. sqm
sqm 1477.30

368
368 SUB HEAD:: 26.0 NEW
SUB NEW TECHNOLOGIES AND
AND MATERIAL•S
MATERIALS
Code No Description Unit Rate
26.52 Erection
Erection of of GFRG
GFRG Panels
Panels in walls in
in walls all floors
in all floors using suitable crane
using suitable crane asas
per instructions of Engineer-in-Charge, as as per cutting drawings and and
structural drawings, in perfect line and and plumb, above RCC RCC plinth beam/
GFRG panel below and and provide necessary lateral/ slanting support to
keep thewall
the wall panel in safe position,position, providing
providing&& tieing of Reinforcement
as per structural drawings and and applyinga
applying a coat of of water repellant coating
Zycosil/equivalent or
Zycosil/equivalent or equivalent
equivalent product
product (1 Zycosil/equivalent compound
(1 Zycosil/equivalent compound
:10 water) to
:10water) to saturation
saturation level over RCC
level over RCC plinth
plinth beam
beam to to provide water
provide water
proofing treatment to
proofing treatment to joint
joint between
between wallwall panel
panel && plinthplinth beam
beam asas per the
perthe
lines/ / instruction by
guide lines by the
the engineer in charge. (Cost of of reinforcement,
water proofing
water proofing of of walls
walls and
and plinth
plinth beam/GFRG
beam/GFRG panel panel below joints and
below joints and
installation
installation of of door/ window frames
door/ window frames before filling of
before filling of concrete
concrete shall
shall be
be paid
paid
separately).
separately). The The rate
rate quoted shall include
quoted shall include making
making provision for laying
provision for laying
lintels, beams, sunshades,
of lintels, sunshades, staircase beams, lofts, plumbing work,
electrical conduits and and anyany structural insertion etc., as as per
per the
the drawing
and direction of the
and the engineer in charge. The The payment shall be be made
based
based on on theactual
the actual exposed
exposed area area (one side only)
(one side only) ofof the
the panel.
panel.
The
The work shall be be carried out out as per the
as per the Special Conditions for for Glass
Fibre
Fibre Reinforced
Reinforced Gypsum
Gypsum (GFRG)(GFRG) Structures
Structures mentioned
mentioned in in NIT.
NIT.
Note:
Note: i) When cutting
i) When cutting panel,
panel, “A”“A” side
side is to be
is to for outside
be for outside oror external
external surface
surface
of respective external wall and
of andBB side is to to bebe for
for internal surface of wall
ii)
ii) Erection
Erection of of panel
panel is to be
is to with reference
be with reference to to both
both building
building plan
plan&& cutting
cutting
drawing by following notational mark indicated in the the cutting drawing as
well as
as notional mark written on on each panel cut cut as
as per cutting drawing sqm
sqm 283.25
26.53 Filling
Filling of of empty
empty cavities
cavities (as shown in
(as shown the structural
in the structural design drawing) with
design drawing) with
quarry
quarry dust dust mixed
mixed with with 5%
5% cement
cement (by volume). After
(byvolume). After initial
initial infill of 50
infill of 50 mm mm
thick with
thick with M25
M25 concrete
concrete at at base/bottom
base/bottom of of cavities
cavities toto seal off, infill
seal off, wall
infill wall
panel cavities in in3 3 stages as detailed below,
(i)
(i) 1st
1st pour
pour// infill
infill toto be
be limited to 0.3
limited to to 0.50
0.3 to 0.50 mm height from bottom
height from bottom of of the
the
panel.
(ii) 2nd Pour/
(ii) 2nd Pour/ infill:
infill: infilling
infilling shall
shall be
be done
done only
only after
after 90 90 minutes
minutes interval
interval
between
between successive
successive pours. The maximum
pours. The maximum height of infill
height of shall be
infill shall be restricted
restricted
to 1.5
1.5 m m height or up up to the top level of door// window.
(iii)
(iii) 3rd
3rd pour/infill: After an
pour/infill: After an interval of 90
interval of 90 minutes
minutes of second pour,
of second pour, infill
infill or
or
pour the the balance height up up to the bottom ofembedded
of embedded RCC RCC tie beam. Pour
enough water just required to dampen thedrymixenough the dry mix enough toform to form cake
form after each stage.
(cost
(cost of of laying
laying M25
M25 concrete
concrete shall
shall be
be paid
paid separately)
separately)
(If any
any rain falls in between any stages of of concrete pour, make sure to to
cover the panel top to to prevent ingress of water or or water falling into the the
cavities. In case of of water collection over the concrete inside the the panel,
drill
drill 1010 mm
mm hole
hole inin GFRG
GFRG panel
panel immediately above concrete
immediately above concrete filledfilled level
level to to
drain
drain out water before
out water before pour/in-fill of balance
pour/in-fill of balance concreting)
concreting) cum
cum 2604.30
26.54 Laying
Laying of
of GFRG
GFRG panelpanel as
as roof
roof// floor
floor slab
slab panel
panel and staircase panel
and staircase panel
using suitable crane as per instructions of Engineer-in-Charge, including
providing support system with 25 mm xx 300mm-400 mm
25 mm mm wide plywood, as
runner with proper prop below proposed micro beams including
(a)
(a) Cutting of top
Cutting of top flange
flange ofof panel to 180
panel to 180 mm wide (leaving
mm wide 25 mm
(leaving 25 mm
projection on either
projection on either side) to provide
side) to provide RCC
RCC embedded
embedded micro
micro beam
beam asas per
per
cutting drawings and
and structural drawings.
(b)
(b) Reinforcement
Reinforcement for for micro
micro beams
beams and tie beams
and tie to be
beams to be provided
provided inin
position with proper anchorage as per per structural drawings.
(c)
(c) Provision for Electrical
Provision for Electrical cabling, fan hooks
cabling, fan hooks and
and laying of pipes
laying of for
pipes for
plumbing work.

SUB HEAD:
SUB HEAD : 26.0 NEW
NEW TECHNOLOGIES AND
AND MATERIALS 369
Code No Description Unit Rate
(d) Concreting of
(d)Concreting Tie beam,
of Tie beam, micro
micro beam
beam and top of
andtop GFRG panels
ofGFRG panels (50
(50 mm
mm
thick) with
thick) with M-25 cement concrete
M-25 cement concrete mix
mix using
using coarse
coarse aggregate of size less
aggregate ofsize less
than 20 mm including laying of 10
20 mm 10 gauge 100x100 mm mm size weld mesh
with 25
with 25 mm effective cover
mm effective from the
cover from the panel top.
panel top. sqm
sqm 287.40
26.55 Supplying and fixing
Supplying and fixing 10
10 Gauge weld mesh
Gauge weld of size 100
mesh ofsize 100 mm x100 mm
mm x100 for
mm for
floor/roof slab
floor/roof slab concrete
concrete screed over the
screed over the micro
micro beams
beams asas reinforcement.
reinforcement.
The weld
The weld mesh shall be
mesh shall fixed as
be fixed as per drawing.
per drawing. sqm
sqm 254.75
26.56 Application of
Application ZMB 60/equivalent
of ZMB solution (100
60/equivalent solution (100 Kg ZMB 60/equivalent,1
Kg ZMB 60/equivalent, 1
litre ZMB Nano
litre ZMB Thinner, 20
Nano Thinner, 20 litre water &11 Litre
litre water& Zycoprime/equivalent =
Litre Zycoprime/equivalent =
122
122 litre/kg) over already
litre/kg) over already applied coat of
applied coat Zycosil/equivalent&& Zycoprime/
of Zycosil/equivalent Zycoprime/
equivalent solution on on the
the top
top of all the RCC plinth beams by
the RCC by brush/spray
coat before erection of GFRG over RCC RCC plinth beams in GF. GF. In the
the case
of
of upper floors 150
upper floors 150 mm wide on
mm wide on floor
floor slab for all
slab for all the
the external walls, bath/
external walls, bath/
toilet/wet areas
toilet/wet areas (3
(3 hrs drying time)
hrs drying time) before
before erection
erection of wall panel
of wall on upper
panel on upper
floors including
floors including erection of parapet
erection of wall.
parapet wall. sqm
sqm 371.25
26.57 After erection of GFRG wall panels, seal all GFRG wall joints with paper
tape temporarily.
tape temporarily. Water
Water proofing treatment of
proofing treatment of vertical
vertical joints
joints with
with Zycosil/
Zycosil/
equivalent water proofing
equivalent water proofing Solution
Solution (1
(1 litre
litre ofof Zycosil/equivalent&
Zycosil/equivalent & 20 20 litres
litres
of water stirred
of water stirred first&
first &2 2 litres of Zycoprime/equivalent
litres of Zycoprime/equivalent added added andand stirred
stirred
(total 23 litres))
(total 23 with 50
litres)) with 50 ml syringe till
ml syringe till the
the gapgap and
and in filled concrete
in filled concrete isis
completely saturated. After
completely saturated. After removing
removing thethe paper seal, seal
paper seal, off the vertical
seal offthe vertical
joints with
joints with water
water proofing
proofing material
material “Grout
“Grout RW/equivalent”
RW/equivalent” (Sealing
(Sealing cost
cost
excluded.)
excluded.) metre 92.45
26.58 Filling
Filling of joints between
of joints between RCC RCC plinth
plinth beam
beam// floor
floor slab and wall
slab and wall panel
panel of
of
external walls, toilet/
external walls, toilet / bath
bath room
room// wet
wet areas walls on
areas walls on all floor and
all floor and parapet
parapet
wall over roof slab, stair case head room at atthetime
the time of
of erection of GFRG
panels with Grout RW/equivalent sealant compound after the the erection of
panel
panel before
before thethe infill
infill of concrete in
of concrete in panel
panel cavities and fine
cavities and fine finish.
finish. This
This
applies for horizontal and
for all horizontal and vertical joints between GFRG wall and and slab
panels. metre 49.30
26.59 Water proofing
Water treatment of
proofing treatment of Vertical
Vertical joints
joints (of
(of external side and
external side and internal
internal
side)
side) between
between door frame, window&
door frame, window & ventilator
ventilator frames
frames (on all four
(on all four sides)
sides)
of
of outer wall over
outer wall the Zycosil/equivalent&
over the Zycosil/equivalent & Zycoprime/equivalent
Zycoprime/equivalent solution
solution
already applied (before the installation of door// window// ventilator frames
in
in position) and fine
position) and fine finish
finish with
with Grout
Grout RW/equivalent.
RW/equivalent. metre 49.95
26.60 Water proofing
Water treatment of
proofing treatment of RCC
RCC sunshade with Zycosil/equivalent
sunshade with Zycosil/equivalent water
water
proofing Solution (1
proofing Solution (1 litre
litre of Zycosil/equivalent & 20
of Zycosil/equivalent& 20 litres
litres of water stirred
of water stirred
first &2 2 litres
first& of Zycoprime/equivalent
litres of Zycoprime/equivalent added and stirred
added and stirred (total 23 litres))
(total 23 litres))
till it meets the
the saturation level and
and testing as
as per
per RILEM or or by
by water
drops test in which water drops do not absorb but
do not but drops remain or or rolls. sqm
sqm 136.45
26.61
26.61 In-filling
In-filling/ / sealing of joint
sealing of joint between
between RCC
RCC lintel
lintel cum sunshade and
cum sunshade and wall
wall (on
(on
external
external side)
side) in all floors
in all floors by
by pushing
pushing in
in Grout
Grout RW/equivalent
RW/equivalent in in paste form
paste form
and
and coving
coving 2020 mm
mm xx 20 20 mmmm after
after applying
applyingaa coat of Zycosil/equivalent
coat of Zycosil/equivalent
&& zycoprime/equivalent solution before cement plastering of top, bottom
and sides of RCC
and RCC sunshade. metre 49.95
26.62 Designing,
Designing, Providing,
Providing, installing
installing and fixing factory
and fixing factory finished
finished customed
customed
design pregalvanized high tensile steel joists manufactured from G350
Z275 confirming
Z275 to IS:277-1992,
confirming to IS:277-1992, minimum
minimum coating of galvanizing
coating of galvanizing 275
275 gm/
gm/
sqm, minimum yield stress 35 35 MPa
MPa && minimum tensile strength of 380380
MPa placed 1.23 metre apart to support the load of slab etc as
MPa as per the
design&& directions of Engineer-in-Charge.
design kg 182.05

370
370 SUB HEAD
SUB HEAD:: 26.0 NEW
NEW TECHNOLOGIES AND
AND MATERIAL.S
MATERIALS
Code No Description Unit Rate
26.63 Providing
Providing and fixing special
and fixing special adjustable
adjustable lockbars of mild
lockbars of mild steel
steel E-250
E-250 toto
support the temporary plywood forwork
for work between joists during construction
as per design
as design&& directions of the
the Engineer-in-charge. kg 27.10
26.64 Centering and shuttering
Centering and shuttering with
with 12
12 mm thick shuttering
mm thick shuttering plywood
plywood confirming
confirming
to IS 4990:2011
4990:2011 and
and removal of of form atat all heights. Plywood will be
be
on lock bars.
supported on
26.64.1
26.64.1 Suspended floors, roofs,
Suspended floors, roofs, landings,
landings, balconies
balconies and
and access
access
platform.
platform. sqm
sqm 106.80
2665
26.65 Providing and fixing
Providing and fixing roofing
roofing consist
consist of
of 0.8
0.8 mm thick galvanized
mm thick galvanized steel
steel
deck sheet confirming
deck sheet confirming toto IS 277:1992 used
IS 277:1992 as permanent
used as permanent shuttering over
shuttering over
which MSMS wire mesh
mesh33 mm mm laid at 100x100 mmmm grid including edge trim
covered with concrete. This metal deck will be be supported on structural
on structural
steel beam with shear studs. (Structural steel like Beam, column, joists
etc.
etc.& & concrete
concrete of
of different grade as
different grade as per design will
per design will be
be paid
paid separately).
separately). sqm
sqm 1525.60
26.66 Providing
Providing and fixing in
and fixing in position,
position, 130
130 mm thick factory
mm thick factory made
made Expanded
Expanded
Polystyrene
Polystyrene Core Core (EPS(EPS Core) wall panels
Core) wall panels consisting
consisting of of EPS core
EPS core
sandwiched between two Engineered sheets of of welded wire fabric mesh
duly finished with
duly finished with shortcrete
shortcrete materials
materials onon outer
outer faces.
faces. The
The fabric
fabric mesh
mesh
be made of
shall be of33 mm
mm diadia zinc coated G.I. wire mesh with 50 50 mm
mm pitch
in both the directions and and onon both faces of of the wall andand connected by
GI wire of of33 mmmm dia at alternate row row by
by welding. The EPS core shall
The EPS
consist of 6060 mmmm thick EPS EPS of density not less than 16 kg/ kg/ cum. Both the
outer faces of
outer faces of the
the panel
panel shall
shall be finished by
be finished applying the
by applying the layer of 35
layer of 35 mm
mm
thick cement mortar
mortar11:3 :3 (1 cement:33 coarse sand (not having more than
{1 cement:
40% stone
40% stone chips
chips of of size
size upto
upto66 mm)} with the
mm)) with the help
help of
of shotcreting/guniting
shotcreting/guniting
equipment
equipment etc etc atataa pressure
pressure not
not less than 1 bar
less than1 bar (100KN/m2)
(100KN/m2) and and both
both
surfaces finished with
surfaces finished with trowel.
trowel. Fixing operations of
Fixing operations of wall
wall panels shall be
panels shall be
completed
completed in in all
all respect
respect asas per drawings and
per drawings specifications and
and specifications and under the
under the
overall direction of the the Engineer-in-charge. sqm
sqm 2673.70
26.67 Providing and fixing
Providing and fixing of
of external thermal insulation
external thermal and composite
insulation and composite system
system
with First
with First layer
layer ofof self-extinguishing
self-extinguishing type type Expanded
Expanded Polystyrene
Polystyrene (EPS)
(EPS)
insulation
insulation boards
boards of of 120
120 mm thick ( max
mm thick( max 1mX0.5m section), confirming
1mX0.5m section), confirming
to IS 4671:1984, having thermal conductivity of 0.034 W/mK, (measured
as
as per
per IS
IS 3346-1980),
3346-1980), density
density of 20-24 kg/m³
of 20-24 kg/m° measured
measured as as per
per IS
IS 5688-
5688-
1982, Fire retardant property self-extinguishing type as per EN EN 13501-1,
bonded with special
bonded with special polymer
polymer modified cementitious adhesive
modified cementitious adhesive confirming
confirming
to EOTA
to EOTA ETAG
ETAG 004 (European Technical
004(European Technical Approval)
Approval) formulated
formulated to to bond
bond
polystyrene insulation boards to to typical mineral substrate (according
to ETAG
to ETAG 004)
004) andand Polypropylene
Polypropylene mechanical fasteners with
mechanical fasteners with plastic
plastic pin
pin
confirming
confirming to to EOTA
EOTA ETAG 014 (European Technical
ETAG 014(European Technical Approval)
Approval) having dia
having dia
10
10 mm
mm && L=200
L=200 mm mm on on finished
finished level wall and
level wall the junction
and the junction between
between
two adjacent EPS EPS boards to to be sealed with low low expansion moisture cure
Polyurethane Foam. Second layer consists of Fiberglass mesh covered
with alkali-resistant
with alkali-resistant coating,
coating, mass
mass per unit area
perunit area *145
≥145 g/m²,
g/m*, mesh
mesh size:
size:
3.9x4.0
3.9x4.0 mm ±10% embedded
mm +10% embedded in in special
special polymer
polymer modified
modified cementitious
cementitious
Base Coat with hydrophobes and and the
the corners will be be protected with
Corner-beads with alkali-resistant mesh wings atleast at least 1010 cm
cm wide, mesh
mass
mass per unit area
perunit area min
min 145
145 g/m². The surface
g/m*. The surface will
will be
be levelled, finished,
levelled, finished,
made
made smooth
smooth complete
complete in all respect
in all respect asas per
per manufactures specification
manufactures specification
and as
and as per
per directions of Engineer-in-Charge. sqm
sqm 3935.35
26.68 Providing andand laying factory made Precast concrete solid blocks of
200 mm
200 mm thickness of grade M10 M10 made of ofC&D
C&D waste from approved
manufacturer in foundation and and plinth in:
26.68.1
26.68.1 Cement
Cement mortar
mortar 1:6
1:6 (1 cement :6 6 coarse
(1 cement: coarse sand)
sand) cum
cum 7387.25

SUB HEAD:: 26.0 NEW


SUB NEW TECHNOLOGIES AND
AND MATERIALS 371
Code No Description Unit Rate
26.69 Providing and and laying factory made Precast concrete solid blocks of
200
200 mm mm thickness of grade M10 M10 made of ofC&D
C&D waste from approved
manufacturer
manufacturer in in superstructure
superstructure above
above plinth
plinth level
level up to floor
up to floorV V level
level
26.69.1
26.69.1 Cement
Cement mortar
mortar 1:6
1:6 (1 cement :6 6 coarse
(1 cement: coarse sand)
sand) cum
cum 9844.65
26.70 Providing and and laying half block masonry with factory made Precast
concrete solid blocks of of 100
100 mm
mm thickness of grade M10 M10 made ofC&Dof C&D
waste from approved manufacturer in foundation and and plinth in:
26.70.1
26.70.1 Cement
Cement mortar
mortar 1:4(1 cement : 4 coarse
1:4(1 cement:4 coarse sand)
sand) sqm
sqm 897.15
26.71
26.71 Providing and and laying half block masonry with factory made Precast
concrete solid blocks of of 100
100 mm
mm thickness of grade M10 M10 made ofC&Dof C&D
waste from approved manufacturer in superstructure above plinth level
up
up toto floorV
floor V level:
level:
26.71.1
26.71.1 Cement
Cement mortar
mortar 1:4
1:4 (1 cement : 4 coarse
(1 cement:4 coarse sand)
sand) sqm
sqm 1099.15
26.72 Providing and and laying 6060 mm
mm thick factory made cement concrete paver
block of approved shape and colour ofM of M -30 grade made ofC&D of C&D waste
by block making machine with vibratory compaction laid in required
pattern andand including over 50 50 mm
mm thick compacted bed of of coarse sand,
filling the
filling the joints
joints with
with fine
fine sand
sand etc.
etc. all
all complete
complete asas per the direction
per the direction of
of
Engineer-in-charge. sqm
sqm 829.75
PREFAB/PRECAST TECHNOLOGY
26.73 Fabrication&& Manufacturing
Fabrication Manufacturing of Prestressed
Prestressed Hollow Core slab (Hollow
area
area 25 to 30%)
25 to 30%) ofof different
different thickness&
thickness & modular width 1200
modular width 1200 mmmm inin
Controlled Factory Environment with approved methodology conforming
Controlled
to
to IS:: 10297:1982 by using long line casting method having arrangement
of proper steel bed. Concreting should be
of be done by batch mixing plant
capable ofof producing zero slump concrete,
concrete, transported through automatic
shuttels of standard makemake&& layed on on bed
bed with the help of extruder/
Slipformer, finishing, curing
Slipformer, finishing, curing and
and also
also provision of steam
provision of steam curing.
curing. Cutting,
Cutting,
making necessary cutout/holes of required sizes for for services in slab
element after achieving required strength, yard handling
handling&& stacking all
complete as per perapproved
approved shop drawings&
drawings & design mix as per the direction
of the Engineer-in-charge.
of the Engineer-in-charge. (Cost of strands
(Cost of strands should
should be
be paid separately).
paid separately).
Note:
Note: Excess/less
Excess/less cement over the
cement over the specified
specified cement
cement content
content used
used as
as per
per
design mix
design mix is
is payable/recoverable separately)
payable/recoverable separately)
26.73.1
26.73.1 Concrete
Concrete Grade-M-40
Grade-M-40 (cement content 400
(cement content 400 kg
kg))
26.73.1.1
26.73.1.1 100 mm
100 mm thick hollow core slab metre 1287.25
26.73.1.2 120 mm
120 mm thick hollow core slab metre 1501.40
26.73.1.3 150 mm
150 mm thick hollow core slab metre 1822.60
26.73.1.4 200 mm thick hollow core slab
200 mm metre 2217.00
26.73.1.5 250 mm thick hollow core slab
250 mm metre 2717.10
26.73.1.6 300 mm thick hollow core slab
300 mm metre 3217.20
26.73.1.7 350 mm thick hollow core slab
350 mm metre 3717.25
26.73.1.8 400 mm thick hollow core slab
400 mm metre 4217.35
26.73.2 Extra for using
Extra for using M-50
M-50 (Cement content 425
(Cement content 425 kg)
kg) instead of
instead of
M-40
26.73.2.1
26.73.2.1 100 mm
100 mm thick hollow core slab metre 18.40
26.73.2.2 120 mm
120 mm thick hollow core slab metre 22.10
26.73.2.3 150 mm
150 mm thick hollow core slab metre 27.65

372
372 SUB HEAD:: 26.0 NEW
SUB NEW TECHNOLOGIES AND
AND MATERIAL•S
MATERIALS
Code No Description Unit Rate
26.73.2.4 200 mm
200 mm thick hollow core slab metre 34.40
26.73.2.5 250 mm
250 mm thick hollow core slab metre 43.00
26.73.2.6 300 mm
300 mm thick hollow core slab metre 51.60
26.73.2.7 350 mm
350 mm thick hollow core slab metre 60.20
26.73.2.8 400 mm thick hollow core slab
400 mm metre 68.80
26.73.3 Extra for using
Extra for using M-60
M-60 (Cement content 440
(Cement content 440 kg)
kg) instead of
instead of
M-40
26.73.3.1
26.73.3.1 100 mm
100 mm thick hollow core slab metre 29.50
26.73.3.2 120 mm
120 mm thick hollow core slab metre 35.35
26.73.3.3 150 mm
150 mm thick hollow core slab metre 44.20
26.73.3.4 200 mm thick hollow core slab
200 mm metre 55.00
26.73.3.5 250 mm thick hollow core slab
250 mm metre 68.80
26.73.3.6 300 mm
300 mm thick hollow core slab metre 82.55
26.73.3.7 350 mm
350 mm thick hollow core slab metre 96.30
26.73.3.8 400 mm thick hollow core slab
400 mm metre 110.05
26.74 Fabrication and and manufacturing
manufacturing of solid precast concrete element with
provisions of shear keys, connecting loops, dowel tubes and and proper
lifting accessories forwalls, stairs, column etc, of various
for walls, beams, slabs, stairs,
thickness, shape
thickness, shape andand size
size of
of different
different concrete
concrete grades
grades manufactured
manufactured
in controlled factory environment with approved methodology including
moulds (Pallet system, Tilts form, table moulds, battery moulds, vertical
moulds, beam moulds, column moulds, staircase moulds, Facade mould,
etc.),
etc.), mixing, transporting and
mixing, transporting and placing of concrete,
placing of concrete, vibrating,
vibrating, curing,
curing,
finishing, making
finishing, making necessary
necessary cutout/holes
cutout/holes ofof required
required sizes for services,
sizes for services,
yard handling
handling&& stacking all complete as per per IS
IS:: 11447:1985 and
and as per
per
approved shop drawings and and design mix as per the direction of Engineer-
in-Charge (Cost of Mechanical, Electrical and
of reinforcement, Mechanical, and Plumbing
inserts will be
inserts will be paid separately).
paid separately).
26.74.1
26.74.1 Concrete grade M-35
Concrete grade M-35 (Cement
(Cement content
content 370
370 kgs)
kgs) cum
cum 20928.70
26.74.2 Extra for using
Extra for using M-40
M-40 (Cement content 400
(Cement content 400 kg)
kg) instead of
instead of
M-35 cum
cum 245.65
26.74.3 Extra for using
Extra for using M-50
M-50 (Cement content 425
(Cement content 425 kg)
kg) instead of
instead of
M-35 cum
cum 450.40
26.74.4 Extra for using
Extra for using M-60
M-60 (Cement content 440
(Cement content 440 kg)
kg) instead of
instead of
M-35 cum
cum 573.20
26.75 Providing
Providing&& laying
laying in
in position
position Prestressing steel strands
Prestressing steel strands (low
(low relaxation)
relaxation)
on hollow core bed
on bed by using mechanical pulling arrangement like
Bed master including all accessories forStressing&
Rabbit/ Bed for Stressing & destressing
operations as
as per approved make conforming to IS:: 1343
to IS 1343&& grade FY-
1860 etc, complete as per
per drawings and
and direction of Engineer -in-charge.
-in-charge. kg 192.35
26.76 Transportation of
Transportation of Precast
Precast Elements
Elements by flat bed
by flat Trailor (Double
bed Trailor (Double// Triple
Triple
axle 40ft Length
axle 40ft with proper
Length with proper accessories
accessories like
likeA A frame
frame etc) from factory,
etc) from factory,
including the
the cost of loading
loading,, unloading
unloading&& stacking at site with the help of
required capacity cranes.
26.76.1
26.76.1 Lead within 15
15 km
km MT
MT 540.85
26.76.2 Add/Deduct over item 26.76.1
26.76.1 for
for every additional lead of
55 km
km MT
MT 117.30

SUB HEAD:: 26.0 NEW


SUB TECHNOL•OGIES AND
NEW TECHNOLOGIES AND MATERIALS 373
373
Code No Description Unit Rate
26.77 Erection && Installation
Installation of Precast/Prestressed Concrete elements in
correct
correct&& final
final position with proper
position with proper line
line level and plumb
level and plumb at at site
site making
making
all arrangements (i.e cranes, push-pull jacks&jacks & all another
anotherTT&& PP for for
Placing&& Alignment of
lifting Placing of elements, within erection tolerance as as per
IS:: 15916 as per
IS per approved shop drawings and and all complete as per the
direction of Engineer-in-Charge but excluding the cost of sim sim pads, nonnon
shrink grout and
shrink grout and steel
steel works
works i.e
i.e hangers. All work
hangers. All work up to fifth floor.
up tofifth floor.
26.77.1
26.77.1 Prestressed hollow core Slab up to
to 200 mm thickness
200 mm sqm
sqm 203.50
26.77.2 Prestressed hollow core slab above 200 mm
mm up to400 mm
to 400 mm
thickness sqm
sqm 345.15
26.77.3 Solid concrete wall elements cum
cum 2720.30
26.78 Providing&& Applying weather proof sealant on
Providing on outer joints of approved
make
make confirming to IS
confirming to IS&& directed
directed by
by Engineer-in-charge.
Engineer-in-charge.
26.78.1
26.78.1 Sealant 25 mm x10
25 mm mm atjoints
x10 mm at joints metre 178.95
26.79 Providing && Laying ofof levelling sim
sim pads required sizes (5x5 cm cm to
10x10 cm) ofPVC
10x10 cm) of PVC// Rubber to adjust level
Rubber toadjust of bearing
level of surface of
bearing surface supporting
of supporting
members asas per
perthedirection
the direction of Engineer in charge.
26.79.1
26.79.1 22 mm
mm thick each 28.90
26.79.2 55 mm
mm thick each 36.00
26.79.3 10 mmmm thick each 51.65
26.80 Providing && Grouting of dowel tubes/ tubes / Shear keys keys// Joints of precast
members
members withwith M-60
M-60 grade
grade cementitious
cementitious groutgrout (Non
(Non Shrink)
Shrink) ofof approved
approved
make
make by by suitable
suitable means
means (Free flowing /pump),curing
(Free flowing /pump),curing etc.etc. Complete
Complete as as
perdirections
per directions of Engineer-in-charge. (The payment shall be be made on on the
the
basis of actual
basis of actual weight
weight ofof approved
approved grout
grout injected.)
injected.)
26.80.1
26.80.1 Stirrer
Stirrer mixed cementitious grout
mixed cementitious grout (non
(non shrink)
shrink) of approved
of approved
make in dowel tubes // Shear keys // Joints of precast
members. kg 85.05
26.81
26.81 Providing
Providing andand fixing
fixing Scaffolding
Scaffolding netnet ofof required width made
required width made of of high
high
density Polyethylene
density Polyethylene UV UV stabilized
stabilized knitted
knitted on on warp
warp knitting
knitting machines
machines
having density 100
having density gram / sqm
100 gram/ sqm andand shading coefficient minimum
shading coefficient minimum 75% 75%
around the
the construction site/ for vertical extension as as per requirement
including fastening/tying with
including fastening/tying with building/scaffolding
building/scaffolding pipes or with
pipes or with any other
any other
fixtures etc.
fixtures complete as
etc. complete as per direction of
per direction of Engineer-in-Charge.
Engineer-in-Charge. (One time
(One time
payment
payment shall
shall be
be made for providing
made for providing Scaffolding
Scaffolding net from start
net from start of work till
of work till
completion of
completion work including
of work shifting ifif any.
including shifting any. The
The Scaffolding
Scaffolding net shall be
net shall be
the property
the of the
property of the contractor
contractor on
on completion
completion of of the
the work)
work) sqm
sqm 29.25
26.82 Providing and laying
Providing and laying rigid
rigid EPS
EPS (cellular
(cellular plastic
plastic material)
material) blocks
blocks conforming
conforming
to ASTM
to ASTM standards/specifications
standards/specifications of of minimum density 21.60
minimum density 21.60 Kg/cum
Kg/cum onon
floors, steps,
floors, steps, stage etc. of
stage etc. of required size and
required size shape as
and shape as per direction of
perdirection of the
the
Engineer-in-Charge. This shall include the following operation.
operation.
The EPS blocks shall be
The EPS be cut
cut to required shape and sizes including cuttings
for passing ofof services, joined together with synthetic resin adhesives as
per
per relevant
relevant specifications
specifications and
and packed/placed
packed/placed in in position for stepped
position for stepped floor
floor
or platform formation.
formation. The
The top andand sides surfaces to be be provided with GI GI
woven wire
woven wire mesh
mesh of aperture 5.45
ofaperture 5.45 mm
mm (with wire dia
(with wire dia 0.90
0.90 mm)
mm) secured
secured toto
EPS blocks with wire pins/clips. Horizontal top surface to be
EPS be provided with
20 mm thick cement concrete 1:2:4 (1
20 mm (1 cement:
cement :2 2 coarse sand:4
sand : 4 graded
stone aggregate
stone aggregate upto
upto66 mm chippings) and
mm chippings) and vertical
vertical surface
surface toto be
be provided
provided
with 12
with 12 mm cement plaster
mm cement plaster 1:4
1:4 (1 cement : 4 coarse
(1 cement:4 coarse sand).
sand).

374
374 SUB HEAD:: 26.0 NEW
SUB NEW TECHNOLOGIES AND
AND MATERIAL•S
MATERIALS
Code No Description Unit Rate
The
The concrete/plastered surfaces so so prepared shall be be scratched with wire
brushes
brushes to to form
form burrs,
burrs, so so as as to
to act
act asas base for flooring or
base forflooring veneering/
or veneering/
panelling to be be done later as as perper approved design (which shall be be paid forfor
separately)
separately) complete
complete as as per direction of
per direction the Engineer-in-Charge.
of the Engineer-in-Charge. sqm
sqm 2293.30
26.83 Applying stamping
Applying stamping finish finish to to the
the top
top surface
surface ofof freshly
freshly laid
laid plain/reinforced
plain/reinforced
cement concrete of
cement concrete of specified
specified grade grade in in porticos,
porticos, sidewalks, driveways,
sidewalks, driveways,
pool decks and open yards as per direction of the the Engineer-in-Charge.
The
The process shall include the following:-
•• The
The concrete
concrete shall shall be be placed
placed and and screeded
screeded to to the
the finished
finished grade,
grade, andand
floated toa
floated to a uniform
uniform surfacesurface by by using standard finishing
using standard finishing techniques.
techniques. The The
approved color hardener hardener@@ 2.7 kg/sqm shall be be applied evenly to the
surface of the fresh concrete by the dry shake method by sprinkling in two two
or
or more
more shakes, floated after
shakes, floated after each
each shake and trowelled
shake and trowelled only only after the final
after the final
floating. The
floating. The approved
approved release release agentagent@@ 0.1130.113 kg/sqm
kg/sqm shall
shall be applied
be applied
evenly to the trowelled surface before stamping or or the said release agent
can
can be applied to
be applied to the
the flexible
flexible polyurethane
polyurethane stampstamp mouldsmoulds of of approved
approved
design
design and and in in required
required sizes sizes to to achieve
achieve final
final stamped
stamped pattern. These
pattern. These
stampings shall be be placed on on the surface of concrete in three to four
pieces
pieces at ataa time
time and tapped gently
and tapped gently with
with rammers
rammers of sufficient size
ofsufficient size&& weight
weight
to
to leave proper stamp marks and theprocess the process repeated forthe for the remaining
concrete surface till the the whole surface to be be stamped is completed within
the
the time while concrete is in plastic stage of of setting.
•• After
After stamping,
stamping, the the curing
curing shallshall be done as
be done as perper manufactures
manufactures
specifications.
specifications. After After initial curing the
initial curing the imprinted
imprinted jointsjoints shall
shall be be grouted
grouted
using cement slurry mixed with color hardener as per the requirement. requirement.
The
The surface shall be be sealed by applying acrylic based sealer not less than
0.167
0.167 litre/sqm.on finished surface.
litre/sqm.on finished surface.
•• The
The construction
construction joints joints shall
shall bebe provided
provided by groove cutting
by groove cutting of of size
size44
mm x x 20
mm 20 mmmm in panel size 3m 3m xx33 m m or lesser as as per the site conditions
and filling the
and filling the same
same with with 10 10 mm mm baker
baker rod and providing
rod and providing and and laying
laying (PU)
(PU)
Polyurethane based joint sealer of approved make as permanufacturer's
as per manufacturer’s
specifications
specifications and and finished
finished by applying Polyurethane
by applying Polyurethane resin resin based
based top top
protective clear coat of of minimum 80 micron applied with rollers on on properly
cured
cured andand dry dry clean
clean surface.
surface. (Cost(Cost of of concrete for flooring is
concrete forflooring is not
not included
included
in this item
in this which shall
item which shall be be paid separately.)
paid separately.) sqm
sqm 762.75
26.84 Supplying
Supplying and and laying
laying of of Uni-Axial
Uni-Axial WovenWoven Polyster
Polyster Geogrid conforming
Geogrid conforming
to
to MORTH 3100 and IRC113, as soil reinforcement/basal reinforcement
including accessories like tie-strips, nuts&& bolts and
tie-strips, nuts and loops/lugs forjoining
for joining
reinforcing elements with the facia pannels, overlaps and and other protective
elements for for synthetic geo-grids and and all other activities required for for
reinforced soil walls, slopes etc complete as per design requirements, requirements,
manufacturer
manufacturer specifications
specifications and and asas per direction of
per direction of engineer-in-
engineer-in- charge.
charge.
26.84.1
26.84.1 Uni Axial Woven
Uni Axial Woven polyster
polyster geogrid
geogrid of of minimum
minimum tensiletensile
strength 40 40 KN/m in the the Longitudinal direction and and 20
20 KN/m
in the
the Transverse direction. direction. sqm
sqm 271.45
26.84.2 Uni Axial Woven
Uni Axial Woven polyster
polyster geogrid
geogrid ofof minimum tensile
minimum tensile
strength 6060 KN/m in the and 20
the Longitudinal direction and 20 KN/m
in the
the Transverse direction.
direction. sqm
sqm 310.30
26.84.3 Uni Axial Woven
Uni Axial Woven polyster
polyster geogrid
geogrid ofof minimum tensile
minimum tensile
strength 8080 KN/m in the and 30
the Longitudinal direction and 30 KN/m
in the
the Transverse direction.
direction. sqm
sqm 385.00
26.84.4 Uni Axial Woven
Uni Axial Woven polyster
polyster geogrid
geogrid ofof minimum tensile
minimum tensile
strength 100100 KN/m in thethe Longitudinal direction and
and 30
30
KN/m in thethe Transverse direction.
direction. sqm
sqm 440.25

SUB HEAD:: 26.0 NEW


SUB NEW TECHNOLOGIES AND
AND MATERIALS 375
Code No Description Unit Rate
26.84.5 Uni Axial Woven
Uni Axial Woven polyster geogrid of
polyster geogrid of minimum tensile
minimum tensile
strength 120
120 KN/m in the
the Longitudinal direction and
and 30
30
KN/m in the
the Transverse direction.
direction. sqm
sqm 470.10
26.84.6 Uni Axial Woven
Uni Axial Woven polyster geogrid of
polyster geogrid of minimum tensile
minimum tensile
strength 150
150 KN/m in the
the Longitudinal direction and
and 30
30
KN/m in the
the Transverse direction.
direction. sqm
sqm 580.65
26.84.7 Uni Axial Woven
Uni Axial Woven polyster geogrid of
polyster geogrid of minimum tensile
minimum tensile
strength 200
200 KN/m in the
the Longitudinal direction and
and 30
30
KN/m in the
the Transverse direction.
direction. sqm
sqm 677.75
26.84.8 Uni Axial Woven
Uni Axial Woven polyster geogrid of
polyster geogrid of minimum tensile
minimum tensile
strength 250
250 KN/m in the
the Longitudinal direction and
and 30
30
KN/m in the
the Transverse direction.
direction. sqm
sqm 819.65
26.84.9 Uni Axial Woven
Uni Axial Woven polyster
polyster geogrid of
geogrid of minimum tensile
minimum tensile
strength 300
300 KN/m in the
the Longitudinal direction and
and 30
30
KN/m in the
the Transverse direction.
direction. sqm
sqm 942.15
26.85 and laying of Bi-Axial Woven Polyster Geogrid conforming to
Supplying and to
MORTH 3100 and IRC113, as soil reinforcement/basal reinforcement
of granular road base and sub base, area stalilization, track bed bed
stabilization, load transfer platforms Including accessories like tie-strips,
tie-strips,
nuts&& bolts and
nuts and loops/lugs forjoining
for joining reinforcing elements with the facia
pannels, overlaps andand other protective elements forsynthetic
for synthetic geo-grids
and all other activities required etc. complete as per
and per design requirements,
requirements,
manufacturer
manufacturer specifications and as
specifications and as per direction of
per direction of engineer-in-
engineer-in- charge.
charge.
26.85.1
26.85.1 Bi Axial Woven polyster geogrid of
of minimum tensile strength
20 Longitudinal and
20 KN/m in both Longitudinal and Transverse direction. sqm
sqm 229.65
26.85.2 BiAxial
Bi Axial Woven polyster geogrid of
of minimum tensile strength
40 Longitudinal and
40 KN/m in both Longitudinal and Transverse direction. sqm
sqm 329.70
26.85.3 BiAxial
Bi Axial Woven polyster geogrid of of minimum tensile strength
60 Longitudinal and
60 KN/m in both Longitudinal and Transverse direction. sqm
sqm 416.35
26.86 Providing
Providing andand fixing
fixing factory
factory made
made single
single extruded WPC (Wood
extruded WPC (Wood Polymer
Polymer
Composite)
Composite) solid solid door/window/Clerestory
door/window/Clerestory windows windows && otherother Frames/
Frames/
Chowkhat
Chowkhat comprising of virgin PVC
comprising ofvirgin PVC polymer
polymer ofofKK value
value 58-60
58-60 (Suspension
(Suspension
Grade), calcium carbonate
Grade), calcium carbonate and and natural fibers (wood
natural fibers (wood powder/
powder/ rice
rice husk/
husk/
wheat husk)
wheat husk) and
and non toxic additives
non toxic additives (maximum toxicity index
(maximum toxicity of 12
index of for 100
12 for100
gms) fabricated with
gms) fabricated with miter joints after
miter joints after applying
applying PVC solvent cement
PVC solvent cement and
and
screwed with full body threaded star headed SS SS screws having minimum
frame density
frame density ofof 750
750 kg/cum, screw withdrawal
kg/cum, screw withdrawal strength
strength ofof 2200
2200NN (Face)
(Face)
&& 1100
1100NN (Edge),
(Edge), minimum compressive strength
minimum compressive strength of
of 58
58 N/mm2,
N/mm2, modulus
modulus
of elasticity 900
of elasticity 900 N/mm2
N/mm2 and and resistance
resistance to to spread
spread of of flame
flame ofof Class
ClassAA
category with property of being termite/borer proof, water/moisture
proof and fire
proof and fire retardant
retardant and and fixed
fixed in
in position with M.S
position with M.S hold fast/lugs/SS
hold fast/lugs/SS
dash fasteners of required dia and and length complete as per direction of
Engineer-In- Charge. (M.S hold fast/lugs or SS SS dash fasteners shall be be
paid for separately).
paid for separately).
Note: For WPC WPC solid door/window frames, minus minus55 mm mm tolerance in
dimensions
dimensions i.e i.e depth
depth and width of
and width of profile shall be
profile shall be acceptable. Variation in
acceptable. Variation in
profile dimensions on
profile dimensions on plus
plus side shall be
side shall acceptable but
be acceptable but no extra payment
no extra payment
on this account shall be be made.
26.86.1
26.86.1 Frame size 45x 45 x 7070 mm
mm metre 705.85
26.86.2 Frame size 45x 45 x 8585 mm
mm metre 926.35
26.86.3 Frame size 50 50xx 100
100 mm
mm metre 947.70
26.86.4 Frame size 50 50xx 125
125 mm
mm metre 1075.70

376
376 SUB HEAD:: 26.0 NEW
SUB NEW TECHNOLOGIES AND
AND MATERIAL•S
MATERIALS
Code No Description Unit Rate
26.86.5 Frame size 65 65xx 100
100 mm
mm metre 1111.30
26.86.6 Frame size 65 65xx 125
125 mm
mm metre 1381.60
26.86.7 Frame size 65 65xx 150
150 mm
mm metre 1637.65
26.87 Providing
Providing andand fixing
fixing factory
factory made
made single
single extruded
extruded WPC WPC (Wood
(Wood Polymer
Polymer
Composite) solid plain
Composite) solid flush door
plain flush door shutter
shutter of of required
required size
size comprising
comprising ofof
virgin polymer
virgin polymer of ofKK value
value 58-60
58-60 (Suspension
(Suspension Grade),
Grade), calcium carbonate
calcium carbonate
and
and natural fibers (wood
natural fibers (wood powder/
powder/ rice
rice husk/wheat
husk/wheat husk) husk) and
and non toxic
non toxic
additives
additives (maximum toxicity index
(maximum toxicity index of
of 12 for 100
12 for 100 gms)
gms) having
having minimum
minimum
density
density ofof 650
650 kg/cum
kg/cum and screw withdrawal
and screw withdrawal strength
strength ofof 1800
1800NN (Face)
(Face)
&& 900
900NN (Edge),
(Edge), minimum
minimum compressive
compressive strength
strength 50 50 N/mm2,
N/mm2, modulus
modulus
of elasticity 850
of elasticity 850 N/mm2
N/mm2 and and resistance
resistance toto spread
spread of flame of
of flame Class A
of ClassA
category with property of being termite/borer proof, water/moisture proof
and fire retardant
and fire retardant and and fixing
fixing with
with stainless
stainless steel
steel butt
butt hinges
hinges of
of required
required
size with necessary full body threaded star headed counter sunk S.S
screws, all as per direction of Engineer-In- Charge. (Note: stainless steel
as per
butt
butt hinges and necessary
hinges and necessary S.S S.S screws
screws shall
shall be
be paid separately)
paid separately)
26.87.1
26.87.1 30
30 mm mm thick sqm
sqm 4346.70
26.87.2 35 mm
35 mm thick sqm
sqm 5015.35
26.88 Providing and fixing
Providing and fixing factory
factory made
made single
single extruded
extruded WPCWPC (Wood
(Wood Polymer
Polymer
Composite) solid decorative
Composite) solid decorative typetype flush
flush door
door shutter
shutter of
of required
required size
size
comprising
comprising of virgin polymer
of virgin polymer of ofKK value
value 58-60
58-60 (Suspension
(Suspension Grade),
Grade),
calcium
calcium carbonate
carbonate andand natural fibers (wood
natural fibers (wood powder/
powder/ rice
rice husk/wheat
husk/wheat
husk) and non
husk) and toxic additives
non toxic additives (maximum toxicity index
(maximum toxicity of 12
index of for 100
12 for gms)
100 gms)
having minimum density of 650 650 kg/cum and screw withdrawal strength
of
of 1800
1800NN (Face)
(Face)&& 900900 NN (Edge),
(Edge), minimum
minimum compressive strength 50
compressive strength 50
N/mm2, modulus of 850 N/mm2 and
of elasticity 850 and resistance to spread of of
flame of
flame of Class
ClassAA category
category withwith property
property of of being termite/borer proof,
being termite/borer proof,
water/moisture proof
water/moisture proof and fire retardant.
and fire retardant. WPCWPC to to be
be laminated
laminated withwith PVC
PVC
foil of
of minimum 14 14 microns thick of approved design pasted with hot
melt adhesive on
melt adhesive on both faces of
both faces shutter and
of shutter fixing with
and fixing with stainless steel butt
stainless steel butt
hinges ofof required size with necessary full body threaded star headed
counter sunk S.S screws, all as per direction of Engineer-In- Charge.
as per
(Note: stainless steel butt hinges and and necessary S.S screws shall be be paid
separately)
separately)
26.88.1
26.88.1 30 mm thick
30 mm sqm
sqm 4764.20
26.88.2 35 mm
35 mm thick sqm
sqm 5432.85
26.89 Providing and fixing
Providing and fixing factory
factory made
made single
single extruded
extruded WPCWPC (Wood
(Wood Polymer
Polymer
Composite)
Composite) solidsolid board
board one one side
side white
white color
color and other side
and other of board
side of board
laminted with PVC
laminted with PVC foilfoil of
of minimum
minimum 14 14 micron thickness of
micron thickness of approved design
approved design
pasted with hot melt adhesive forcup for cup boards, work stations and and bathroom/
kitchen cabinet etc. of required sizes comprising of of virgin polymer of ofKK
value 58-60
value 58-60 (Suspension
(Suspension Grade), Grade), calcium carbonate and
calcium carbonate and natural fibers
natural fibers
(wood
(wood powder/
powder/ ricerice husk/wheat
husk/wheat husk)
husk) and
and non toxic additives
non toxic additives (maximum
(maximum
toxicity index
toxicity of 12
index of for 100
12 for 100 gms)
gms) having
having minimum density of
minimum density of 650
650 kg/cum
kg/cum
and screw withdrawal
and screw withdrawal strength
strength ofof 1800
1800NN (Face)
(Face)&& 900900NN (Edge),
(Edge), minimum
minimum
compressive strength 50 50 N/mm2, modulus of 850 N/mm2 and
of elasticity 850 and
resistance
resistance toto spread
spread of flame of
of flame of Class
ClassAA category
category with
with property
property ofof being
being
termite/borer proof,
termite/borer water/moisture proof
proof, water/moisture proof and fire retardant
and fire retardant and fixing
and fixing
with stainless steel piano hinges/soft close clip on on concealed hinges of of
required size with necessary full body threaded star headed counter sunk
S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless
as per
steel piano hinges/soft close clip on on concealed hinges and and necessary S.S
screws shall be
screws shall be paid separately)
paid separately)

SUB HEAD:: 26.0 NEW


SUB NEW TECHNOLOGIES AND
AND MATERIALS 377
Code No Description Unit Rate
26.89.1
26.89.1 18 mm
18 mm thick sqm
sqm 2992.90
26.89.2 25
25 mmmm thick sqm
sqm 3889.15
26.90 Providing
Providing andand fixing
fixing factory
factory made single extruded
made single WPC (Wood
extruded WPC (Wood Polymer
Polymer
Composite)
Composite) solidsolid plain white color
plain white color board
board forfor backing of cup
backing of cup boards
boards andand
bathroom/kitchen cabinets etc. of required size comprising comprising of virgin
polymer
polymer ofKof K value
value 58-60
58-60 (Suspension
(Suspension Grade),
Grade), calcium
calcium carbonate
carbonate and and
natural fibers (wood
natural fibers (wood powder/
powder/ rice
rice husk/wheat
husk/wheat husk)
husk) and
and non toxic additives
non toxic additives
(maximum toxicity index
(maximum toxicity index of
of 12 for 100 gms)
12 for100 gms) having
having minimum density of
minimum density of 650
650
kg/cum
kg/cum and screw withdrawal
and screw withdrawal strength
strength of
of 1800
1800NN (Face)
(Face)&& 900900NN (Edge),
(Edge),
minimum compressive strength 50 50 N/mm2, modulus of 850 N/
of elasticity 850 N/
mm2
mm2 andand resistance
resistance to to spread
spread of
of flame
flame ofof Class
ClassAA category with property
category with property
of
of being termite/borer proof,
being termite/borer water/moisture proof
proof, water/moisture proof and fire retardant
and fire retardant and
and
fixing with
fixing with stainless
stainless steel
steel screws
screws etc.
etc. all
all as
as per direction of
per direction of Engineer-In-
Engineer-ln-
Charge.
Charge. (Note: stainless steel
(Note: stainless steel screws shall be
screws shall be paid
paid separately)
separately)
26.90.1
26.90.1 66 mm
mm thick sqm
sqm 1099.35
26.90.2 mm thick
12 mm sqm
sqm 1711.10
26.91
26.91 Providing
Providing and fixing factory
and fixing factory made
made 18 18 mm thick single
mm thick single extruded
extruded WPCWPC
(Wood
(Wood Polymer
Polymer Composite) solid plain
Composite) solid white colour
plain white colour board Jali, CNC
board Jali, CNC
(Computer
(Computer numeric
numeric control)
control) routed
routed ofof approved
approved design
design byby Engineer-in
Engineer-in
-charge which are machine cut cut forduct/shaft
for duct/shaft covering, partitions and and
facades comprising of of virgin polymer ofK of K value 58-60 (Suspension
Grade),
Grade), calcium
calcium corbonate
corbonate and and natural fibers (wood
natural fibers (wood powder/
powder/ rice
rice husk/
husk/
wheat husk)
wheat husk) and
and non toxic additives(maximum
non toxic additives(maximum toxicitytoxicity index
index ofof 12 for
12 for
100
100 gms)
gms) having
having minimum density of
minimum density of 650
650 kg/cum
kg/cum andand screw withdrawal
screw withdrawal
strength of 1800
strength of 1800NN (Face)
(Face) minimum compressive strength
minimum compressive strength 5050 N/mm2,
N/mm2,
modulus
modulus of of elasticity
elasticity 850
850 N/mm2
N/mm2 and and resistance
resistance to to spread
spread ofof flame
flame ofof
ClassAA category with properties of being termite/borer proof, water/
Class
moisture
moisture proof and fire
proof and fire retardant
retardant and fixing on
and fixing on M.S
M.S (mild
(mild steel) frame
steel) frame
made of25
of 25xx 2525xx 1.5
1.5mmmm square hollow box box section including applying
aa priming coat of of approved steel primer, placed at at grid made at at1.0
1.0xx 1.0
1.0
m oras
m perrequirement
or as per requirement at at site with necessary stainless steel fasteners
and SS
and SS screws etc., all complete as per direction of Engineer-In- Charge.
(Note:
(Note: M.S
M.S (mild steel) framework
(mild steel) framework withwith priming coat and
priming coat and necessary
necessary SS SS
fasteners and
and SSSS screws shall be be paid separately.
separately. sqm
sqm 3437.15
26.92 Providing and fixing
Providing and fixing of
of façade
façade at at all
all heights
heights withwith extruded
extruded hollow
hollow Clay
Clay
// Terracotta ventilated rainscreen tiles of of height 250/ 300/ 400 400 mm mm and and
length of 595
595 mmmm of approved texture,design and and pattern having Flexural
Strength/
Strength/ Modulus of Rupture of*
Modulus ofRupture of ≥ 14
14 N/m²
N/m* and
and maximum water absorption
maximum water absorption
of
of 10% tested as
10% tested as per
per ISOISO 10545-4:2004(E)
10545-4:2004(E) and and ISO
ISO 10545-3:1995
10545-3:1995
respectively
respectively in true level
in true fixed toa
level fixed to a supporting
supporting aluminium
aluminium framework(AIIoy
framework(Alloy
6063 T5/T6) consisting
6063 T5/T6) consisting of of vertical
vertical ‘T’‘T’ (for
(for intermediates)/
intermediates)/ ‘L’(for ends/
‘L’(for ends/
termination)/ Tubular
termination)/ Tubular sections
sections (at corners)of size
(at corners)of size 80x60x2
80x60x2 mm/ 40x60x2
mm/ 40x60x2
mm // 40x40x2 mm
mm mm respectively,
respectively, spaced atmaximumat maximum spacing of of 600
600 mm mm
c/c matching to
c/c to the tile vertical grid, and and horizontal aluminium ‘C’-clamps‘C'-clamps
of size 56x25x2 mm mm thickness of length 150 150 mmmm at junction of tiles and and ofof
length
length 75
75 mm
mm at wall ends/
at wall corners fixed
ends/ corners fixed onon top
top of
of the
the vertical
vertical sections
sections at at
spacing ofof 250/ 300/ 400 400 mm mm c/cc/c matching to to the tile horizontal grid with
two
two numbers of self-drilling/ / self-tapping SS
of self-drilling SS screws of of size 5.5x25 mm mm
with EPDM
with washers. The
EPDM washers. The vertical
vertical ‘T’/’L/ Tubular’ sections
‘T’/’L/ Tubular’ sections shall
shall be fixed
be fixed
to the
to the wall
wall using
using HDGHDG (hot-dip-galvanized)
(hot-dip-galvanized) steel steel L-brackets
L-brackets (galvanizing
(galvanizing
thickness of
thickness of minimum
minimum 80 80 microns)of
microns)of size size 110x80x6
110x80x6 mm mm at at intermediate
intermediate
vertical aluminium
vertical aluminium profiles
profiles andand ofof size
size 220x110x12
220x110x12 mm mm at outer corners
atouter corners
and stainless steel grade 304,M10 full threaded anchor fasteners with
and
nylon sleeve 100
nylon sleeve 100 mm mm long
Iong (for
(for brick work) and
brick work) and M8M8 expansion anchor
expansion anchor
fasteners 7575 mm
mm long
Iong for concrète surface,
for concrete

378
378 SUB HEAD:: 26.0 NEW
SUB NEW TECHNOLOGIES AND
AND MATERIAi.S
MATERIALS
Code No Description Unit Rate
spacing of of brackets to be be based on onaa structural/ static calculation.
calculation. The
The
brackets shall be be of length 175175 mm
mm at junction of two two vertical aluminium
profiles and of
profiles and of length
length 100
100 mmmm atat intermediate
intermediate points
points ofof vertical
vertical profiles
profiles
and
and shall
shall be fixed to
be fixed to the
the vertical
vertical aluminiumT
aluminium T//LL// Tubular
Tubular profiles
profiles using
using
two
two numbers self-drilling/ self-tapping SS SS screws ofsize
of size 5.5x25 mm mm with
EPDM washers.
EPDM gaskets to
EPDM gaskets to be fixed in
be fixed in between
between brackets and vertical
brackets and vertical profiles. The
profiles. The
tiles shall be
be mounted on the‘C’the ‘C’ clamps such that the the tiles are
are supported
at top and
at and bottom at at both ends. TheThe tiles shall be be additionally secured to to
the horizontal ‘C’
the horizontal ‘C’ clamps using special SS SS clips of required size which
be inserted and
shall be and pressed into position on on the ‘C’ clamps holding the
the ‘C’
tiles and
and the
the cut-tiles shall bebe glued at at points to the horizontal ‘C’ clamps
the horizontal
by using MS MS Polymer sealant adhesive. The The vertical joint open groove
between two adjacent tiles shall be be 55 mm.
mm. The
The tiles andand system shall be be
designed
designed to to resist wind load
resist wind load as
as per
per IS
IS 875
875 (Part
(Part 3)
3) according
according to to different
different
zones. The
The tiles shall bebe installed using the ventilated rain screen principle
with provision
with provision forfor natural ventilation of
natural ventilation of the
the space
space between the façade tiles
between thefaçade tiles
and the structural
and the wall. The
structural wall. The work
work shall
shall be carried out
be carried out as
as per specification,
per specification,
drawing andand as per direction of the the Engineer-in-Charge.
Note
Note:: Scaffolding wherever required
Scaffolding wherever required toto be
be paid separately
paid separately
26.92.1
26.92.1 With 16
With 16 mm thickness (+/-
mm thickness (+/- 10%) terracotta tiles
10%) terracotta tiles of
of grey
grey
colour sqm
sqm 6320.00
26.92.2 With 16
With 16 mm thickness (+/-
mm thickness (+/- 10%) terracotta tiles
10%) terracotta tiles of
of other than
other than
grey colors sqm
sqm 5991.40
26.93 Providing
Providing and fixing of
and fixing of façade
façade at at all
all heights
heights with with extruded
extruded hollow
hollow Clay
Clay//
Terracotta ventilated rainscreen tiles of of height 259/ 309/ 409 409 mm mm andand
lengthof 1190 mm mm of ofapproved
approved texture,design and and pattern having Flexural
Strength/
Strength/ Modulus of Rupture of*
Modulus ofRupture of ≥ 14
14 N/m²
N/m* and
and maximum
maximum waterwater absorption
absorption
of
of 10% tested as
10% tested as per
per ISOISO 10545-4:2004(E)
10545-4:2004(E) and and ISO ISO 10545-3:1995
10545-3:1995
respectively
respectively in true level
in true fixed toa
level fixed to a supporting
supporting aluminium framework (Alloy
aluminium framework (Alloy
6063 T5/T6) consisting
6063 T5/T6) consisting of vertical ‘T’
of vertical ‘T’ (for
(for intermediates)/
intermediates)/ ‘L’ ‘L’ (for ends/
(for ends/
termination)/ Tubular
termination)/ Tubular sections
sections (at corners)of size
(at corners)of size 80x60x2
80x60x2 mm/ 40x60x2
mm/ 40x60x2
mm/ 40x40x2 mm
mm/ mm respectively, spaced atmaximum at maximum spacing of of 1200 mm mm
c/cmatching
c/c matching to to the tile vertical grid, and and horizontal aluminium ‘C’-clamps ‘C'-clamps
of size 56x34x2 mm mm thickness of length 150 150 mmmm at junction of tiles and and of
of
length
length 7575 mm
mm at wall ends/
at wall ends/ corners
corners fixedfixed on top of
on top of the
the vertical
vertical sections
sections at at
spacing of of 250/ 300/ 400 400 mm mm c/c c/c matching to to the tile horizontal
horizontal grid with
two
two numbers of self-drilling/ / self-tapping SS
of self-drilling SS screws of of size 5.5x25 mm mm
with EPDM washers.
The vertical
The vertical ‘T’/’L/ Tubular’ sections
‘T’/’L/ Tubular’ sections shall shall be fixed to
be fixed to the
the wall
wall using
using HDGHDG
(hot-dip-galvanized)
(hot-dip-galvanized) steel steel L-brackets
L-brackets (galvanizing thickness of
(galvanizing thickness of minimum
minimum
80
80 microns)
microns) of size 110x80x6
of size 110x80x6 mm mm at at intermediate vertical aluminium
intermediate vertical aluminium
profiles
profiles and
and ofof size
size 220x110x12
220x110x12 mm mm at outer corners
atouter corners andand stainless steel
stainless steel
grade 304,M10 full threaded anchor fasteners with nylon sleeve 100 100 mmmm
long
Iong (for
(for brick work) and
brick work) and M8 M8 expansion
expansion anchor anchor fasteners
fasteners 75 75 mm mm long for
Iong for
concrète surface, spacing of
concrete of brackets to be be based on onaa structural/ static
calculation. The
calculation. The brackets shall be be of length 175 175 mmmm at junction of two two
vertical aluminium
vertical aluminium profiles
profiles andand of of length
length 100 100 mm mm at at intermediate
intermediate points
points of
of
vertical profiles
vertical profiles and shall be
and shall fixed to
be fixed to the
the vertical
vertical aluminium
aluminiumTT//LL// Tubular
Tubular
profiles
profiles using
using twotwo numbers self-drilling/ self-tapping
numbers self-drilling/ self-tapping SS screws of
SS screws of size
size
5.5x25 mm mm with EPDM washers.
EPDM gaskets to
EPDM gaskets to be fixed in
be fixed in between
between brackets
brackets and and vertical
vertical profiles. The
profiles. The
tiles shall be
be mounted on the‘C’ the ‘C’ clamps such that the the tiles are
are supported at at
top and
and bottom at at both ends. The The tiles shall be be mounted on theC-clamps
the C-clamps
with EPDM
with EPDM profiles
profiles inin between
between such such thatthat the
the tiles
tiles are
are supported
supported at top and
attop and
bottom at at both ends.

SUB HEAD:
SUB HEAD : 26.0 NEW
NEW TECHNOLOGIES AND MATERIELS
AND MATERIALS 379
Code No Description Unit Rate
The
The vertical joint open groove between two adjacent tiles shall be be 10
10 mm.
mm.
The
The tiles and
and system shall be be designed toto resist wind load as 875
as per IS 875
(Part
(Part 3) according to
3) according to different
different zones.
zones. The
The tiles
tiles shall
shall be
be installed
installed using the
using the
ventilated
ventilated rain screen principle with provision forfor natural ventilation of the
the
space
space between the façade
between the façade tiles
tiles and the structural
and the structural wall.
wall. The
The work
work shall
shall
be carried out
be carried out as
as per specification, drawing
per specification, drawing and as per
and as per direction
direction of the
of the
Engineer-in-Charge.
Note
Note:: Scaffolding wherever required
Scaffolding wherever to be
required to be paid separately.
paid separately.
26.93.1
26.93.1 With 24
With 24 mm thickness (+/-10%)
mm thickness terracota tiles
(+/-10%) terracota tiles of
of grey colour
grey colour sqm
sqm 6230.90
26.93.2 With 24
With 24 mm thickness (+/-
mm thickness (+/- 10%) terracotta tiles
10%) terracotta tiles of
of other than
other than
grey colors sqm
sqm 5842.50
26.94 Designing, shop fabricating, supplying,, erecting, stripping and
fabricating, supplying and shifting of
customized Modular Tunnel Formwork system forcast-in-situ
for cast-in-situ monolithic
RCC structures,
RCC structures, using precision steel cubical formworks are molds with
minimum33 mm mm thick hot
hot rolled plain painted/hot dip galvanized M.S. sheets
forpanel
for panel in contact area with necessary framing and and allied accessories
as
as per
per CPWD specifications including
CPWD specifications transporting, storage,
including transporting, storage, assembly,
assembly,
and placing in position for supporting and
hoisting and and holding the formwork in
place till initial setting of the concrète then stripping the
the concrete the formwork, propping
to
to support horizontal surface cleaning and and oiling etc. for shifting to the
the
next cycle, inclusive of all labour, machines and T&P T&P requirements taking
all safety measures etc. as per design and
as per and cycle programme all complete
as per directions of the the Engineer-in-Charge. Design ofTunnel
of Tunnel Formwork
system shall be be provided by concerned service provider/vendor and and the
rate is inclusive of all the
the elements andand all operations forall
for all heights. sqm
sqm 269.40
26.95 Providing andand installation
installation of factory made Structural Stay in place form
work system with double faced panels for for walls, single faced panels for for
roof/ floor slabs,
roof/ floor slabs, L-shaped single faced
L-shaped single faced panels for corners, with
panels forcorners, with necessary
necessary
scaffolding,
scaffolding, struts,
struts, bracing etc. Complete
bracing etc. Complete as as per
per CPWD
CPWD specification
specification and
and
directions of the
the Engineer in Charge. Design ofwalls of walls and
and other members
tobe
to be provided by the supplier
supplier&& shall bebe duly vetted byby any
any engineering
institute of
of National repute such as IITs, NITs etc. and and nothing extra shall
be payable on
be on this account (Additional steel reinforcement/dowels, design
mix concrete of
mix concrète of specified
specified grade,
grade, electrical
electrical and
and plumbing
plumbing conduits
conduits insert for
insert for
services and plastering
services and on either
plastering on either side
side of walls shall
of walls shall be
be paid for separately).
paid forseparately).
Note:- This item
Note:- This shall be
item shall be adopted for building
adopted for building upto
upto G+3
G+3 Storeys only
Storeys only
excluding
excluding seismic zone V.
seismic zone V.
26.95.1
26.95.1 Double
Double panel
panel ofof required thickness (110
required thickness (110 mm
mm && above) with minimum
above) with minimum
weight of
of panel as
as 11.05 kg per sqm
sqm forwalls
for walls with corresponding corners
and jambs strips.
and strips. sqm
sqm 3189.10
26.95.2 Single panel for
for slabs with minimum weight of
of panel as 4.05 kg/sqm for
for
walls with corresponding and jambs strips.
corresponding corners and sqm
sqm 1713.55
26.96 Providing
Providing and
and placing
placing “Stay“Stay in
in Place
Place PVC Wall formwork”
PVC Wall formwork” made
made up of
up of
extruded
extruded Unplasticised
Unplasticised Poly Vinyl Chloride
Poly Vinyl Chloride (uPVC) consisting of
(uPVC) consisting of Main
Main
panel,33 way
panel, way Connector, Starter Channel, Joint Panel, Connection Panels,
Door/Window frame/trim panels etc. all complete as per manufacturer
design and
and forall
for all heights as as per direction of Engineer-in-charge.
(Note:
(Note: Suitable for in
Suitable for fill walls
in fill walls with
with appropriate
appropriate Structural
Structural system).
system).
26.96.1
26.96.1 125
125 mm wide Stay
mm wide Stay in
in Place
Place PVC Wallform made
PVC Wallform of minimum 2.50
made ofminimum 2.50 mm
mm
thick sections and
and minimum weight 21.97 kg /sqm of
offormwork.
formwork. sqm
sqm 2926.70
26.96.2 165
165 mm wide Stay
mm wide Stay in
in Place
Place PVC Wallform made
PVC Wallform of minimum 2.50
made ofminimum 2.50 mm
mm
thick sections and
and minimum weight 29.00 kg /sqm of
offormwork.
formwork. sqm
sqm 3805.05

380
380 SUB HEAD
SUB HEAD:: 26.0 NEW
NEW TECHNOLOGIES AND
AND MATERIAi.S
MATERIALS
COEFFICIENTS
FOR CEMENT
FOR
CONSUMPTION
1.0COEFFICIENTS FOR
1.0 FOR CEMENT CONSUMPTION
3.0MORTAR
3.0

Code Description Unit perunit


Quantity of cement per unit
No.
No. quantity of work (Quintals)

3.1 Cement
Cement Mortar
Mortar11:1
:1 (1
(1 cement
cement::11 fine
fine sand).
sand). cum
cum 10.20

3.2 Cement
Cement mortar
mortar11:2
:2 (1
(1 cement
cement:2: 2 fine
fine sand).
sand). cum
CUM 6.80

3.3 Cement
Cement mortar
mortar11:3
:3 (1
(1 cement
cement::3 3 fine
fine sand)
sand) cum
cum 5.10

3.4
3.4 Cement
Cement mortar
mortar11:4
:4 (1
(1 cement
cement:4: 4 fine
fine sand)
sand) cum
cum 3.80

3.5
3.5 Cement
Cement mortar
mortar11:5
:5 (1
(1 cement
cement::5 5 fine
fine sand).
sand). cum
cum 3.10

3.6 Cement
Cement mortar
mortar11:6
:6 (1
(1 cement
cement::6 6 fine
fine sand).
sand). cum
cum 2.50

3.7 Cement
Cement mortar
mortar11:2
:2 (1
(1 cement
cement:2: 2 coarse
coarse sand).
sand). cum
CUM 6.80

3.8 Cement
Cement mortar
mortar11:3
:3 (1
(1 cement
cement::3 3 coarse sand).
coarse sand). cum
cum 5.10

3.9 Cement
Cement mortar
mortar11:4
:4 (1
(1 cement
cement:4: 4 coarse sand).
coarse sand). cum
cum 3.80

3.10 Cement
Cement mortar
mortar11:5
:5 (1
(1 cement
cement::5 5 coarse
coarse sand).
sand). cum
cum 3.10

3.11
3.11 Cement
Cement mortar
mortar11:6
:6 (1
(1 cement
cement::6 6 coarse sand)
coarse sand) cum
cum 2.50

3.12 Cement
Cement mortar
mortar11:2
:2 (1
(1 cement
cement:2: 2 stone dust).
stone dust). cum
CUM 6.80

3.13 Cement
Cement mortar
mortar11:2
:2 (1
(1 cement
cement:2: 2 marble dust).
marble dust). cum
cum 6.80

3.14 Cement
Cement mortar
mortar11:5
:5 (1
(1 cement
cement::5 5 marble dust).
marble dust). cum
cum 3.10

3.15 White cement


White cement mortar
mortar 1:2
1:2 (1 white cement
(1 white : 2 marble
cement:2 dust).
marble dust). cum
cum 6.80*

3.16 White cement


White cement mortar
mortar 1:3
1:3 (1 white cement
(1 white cement::3 3 marble dust).
marble dust). cum
cum 5.10*

3.17 White cement


White cement mortar
mortar 1:5
1:5 (1 white cement
(1 white cement::5 5 marble dust)
marble dust) cum
cum 3.10“
3.10*

** white cement

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 3.0 MORTAR 383
383
1.0COEFFICIENTS
1.0 FOR CEMENT CONSUMPTION
COEFFICIENTS FOR
4.0
4.0 CONCRETE WORK

Code Description Unit Quantity of cement


No.
No. perunit
per unit quantity of
work (Quintals)
CEMENT CONCRETE (CAST-IN-SITU)

4.1
4.1 P/L cement concrete - all works upto plinth level
P/L level::
4.1.2 1:1’/:3 (1
1:1½:3 (1 Cement
Cement:: 1½1’/coarse
coarse sand derived from
natural sources :: 3 3 graded stone aggregate 20 20
mm
mm nominal size derived
nominal size derived from
from natural
natural sources)
sources) cum
CUM 4.00
4.1.2A 1:1’/:3 (1
1:1½:3 (1 Cement
Cement:: 1½1’/coarse
coarse sand including
manufactured sand derived from Recycled
Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 25%::33 graded
upto 25% graded
stone aggregate 20 mm nominal size Recycled
20 mm
Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 25%
upto 25% cum
CUM 4.00
4.1.3 11:2:4
:2:4 (1
(1 cement :: 2 2 coarse sand derived from
natural sources ::4 4 graded stone aggregate 20 20
mm
mm nominal size derived
nominal size from natural
derived from natural sources)
sources) cum
CUM 3.20
4.1.3A (1 Cement :: 22 coarse sand including
1:2:4 (1
manufactured sand derived from Recycled
Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 25%:4
upto 25% : 4 graded
graded
stone aggregate 20 mm nominal size Recycled
20 mm
Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 25%
upto 25% cum
CUM 3.20
4.1.4 (1 Cement
1:2:4 (1 Cement:: 22 coarse sand derived from
natural sources ::4 4 graded stone aggregate 40 40
mm
mm nominal size derived
nominal size derived from
from natural
natural sources)
sources) cum
cum 3.20
4.1.5 (1 Cement
1:3:6 (1 Cement:: 33 coarse sand derived from
natural sources :: 6 6 graded stone aggregate 20 20
mm
mm nominal size derived
nominal size derived from
from natural sources)
natural sources) cum
CUM 2.20
4.1.5A (1 Cement
1:3:6 (1 Cement::3 3 manufactured sand derived
from Recycled
from Recycled Concrete Aggregate (RCA))
Concrete Aggregate (RCA)) :: 66
graded stone aggregate 20 mm nominal size
20 mm
derived from Recycled Concrete Aggregate
(RCA))
(RCA)) cum
CUM 2.20
4.1.5B (1 Cement
1:3:6 (1 Cement::3 3 manufactured sand derived
from Recycled
from Recycled Concrete Aggregate (RCA))
Concrete Aggregate (RCA)) :: 66
graded stone aggregate 20 mm nominal size
20 mm
derived from Recycled
derived from Aggregate (RA))
Recycled Aggregate (RA)) cum
CUM 2.20
4.1.6 (1 Cement
1:3:6 (1 Cement::3 3 coarse sand derived from
natural sources :: 6 6 graded stone aggregate 40 40
mm
mm nominal size derived
nominal size derived from
from natural
natural sources)
sources) cum
CUM 2.20
4.1.6B 11:3:6
:3:6 (1
(1 Cement
Cement::3 3 manufactured sand derived
from Recycled
from Recycled Concrete Aggregate (RCA))
Concrete Aggregate (RCA)) :: 66
graded stone aggregate 40 mm nominal size
40 mm
derived from Recycled
derived from Aggregate (RA))
Recycled Aggregate (RA)) cum
CUM 2.20
4.1.8 (1 Cement
1:4:8 (1 Cement::4 4 coarse sand derived from
natural sources :: 8 8 graded stone aggregate 40 40
mm
mm nominal size derived
nominal size derived from
from natural
natural sources)
sources) cum
CUM 1.70

384
384 FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 4.0 CONCRETE
CONCRETE WORK
WORK
Code Description Unit Quantity of cement
No.
No. perunit
per unit quantity of
work (Quintals)
4.1.8A (1 Cement
1:4:8 (1 Cement::4 4 manufactured sand derived
from Recycled
from Recycled Concrete Aggregate (RCA))
Concrete Aggregate (RCA)) :: 8 8
graded stone aggregate 40 mm nominal size
40 mm
derived from Recycled
derived from Aggregate (RA))
Recycled Aggregate (RA)) cum
CUITI 1.70
4.1.10 (1 cement:
1:5:10 (1 cement : 55 coarse sand derived from
sources:: 10
natural sources 10 graded stone aggregate 40 40
mm
mm nominal size derived
nominal size derived from
from natural sources)
natural sources) cum
cum 1.30
4.1.10A 1:5:10 (1
(1 Cement
Cement::5 5 manufactured sand derived
from Recycled
from Concrete Aggregate
Recycled Concrete Aggregate (RCA))
(RCA)):: 10
10
graded stone aggregate 40 mm nominal size
40 mm
derived from Recycled
derived from Aggregate (RA))
Recycled Aggregate (RA)) cum
CUITI 1.30
4.1.11
4.1.11 11:5:10
:5:10 (1 cement : 5 fine
(1 cement:5 fine sand
sand derived
derived from
from natural
natural
sources: 1010 graded stone aggregate 40 mm
40 mm
nominal size derived
nominal size derived from
from natural sources)
natural sources) cum
CUM 1.30
4.1.12 1:2:3’/:9 (1
1:2:3½:9 (1 ordinary portland cement
cement::2 2 Fly
Fly ash
ash
3’/z coarse sand derived from natural sources:
: 3½ sources :
9 9 graded stone aggregate 40 mm nominal size
40 mm
derived from
derived from natural sources)
natural sources) cum
CUITI 1.70
4.1.12A 1:2:3’/:9 (1
1:2:3½:9 (1 ordinary portland cement
cement::2 2 Fly
Fly ash
ash
3? manufactured sand Recycled Concrete
: 3½
Aggregate (RCA)
Aggregate (RCA) :: 9 9 graded stone aggregate
graded stone aggregate
40
40 mmmm nominal size derived from Recycled
Aggregate (RA))
Aggregate (RA)) cum
cum 1.70
4.1.13 1:2½:4:11
1:2'/:4:11 (1 ordinary portland
(1 ordinary portland cement
cement:: 2½ fly
2’/ fly
ash :4: 4 coarse sand derived from natural sources:
ash
11 graded stone aggregate 40 mm nominal size
40 mm
derived from derived from natural sources cum
CUITI 1.30
4.1.13A 1:2½:4:11
1:2’/:4:11 (1 ordinary portland
(1 ordinary portland cement
cement:: 2’/z
2½ fly
fly
ash :: 4 4 manufactured sand Recycled Concrete
ash
Aggregate (RCA):
Aggregate (RCA): 11 graded stone
11 graded stone aggregate
aggregate
40 mm nominal size derived from Recycled
40 mm
Aggregate (RA))
Aggregate (RA)) cum
CUITI 1.30
4.2 P/L cement concrete - all works upto plinth level
level::
4.2.2 1:1’/:3 (1
1:1½:3 (1 cement:1½
cement:1’/ coarse sand derived from
natural sources :3 graded stone aggregate 20 mm
20 mm
nominal size derived
nominal size derived from
from natural
natural sources)
sources) cum
cum 4.00
4.2.2A 1:1'/:3 (1
1:1½:3 (1 cement:1½
cement:1'/ coarse sand including
manufactured sand derived from Recycled
Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto
upto 25%:
25%:33 graded
graded
stone aggregate 20 mm nominal size Recycled
20 mm
Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto
upto 25%)
25%) cum
cum 4.00
4.2.3 (1 Cement
1:2:4 (1 Cement:: 22 coarse sand derived from
natural sources:4
sources: 4 graded stone aggregate 20 mm
20 mm
nominal size derived
nominal size derived from
from natural
natural sources)
sources) cum
CUITI 3.20
4.2.3A (1 Cement:
1:2:4 (1 Cement :2 2 including manufactured sand
derived from Recycled
derived from Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA)
upto 25%: 44 graded
upto 25%: graded stone aggregate 20
stone aggregate 20 mm
mm
nominal
nominal size
size Recycled
Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA)
upto 25%)
upto 25%) cum
CUM 3.20

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 4.0 CONCRETE
CONCRETE WORK
WORK 385
385
Code Description Unit Quantity of cement
No.
No. perunit
per unit quantity of
work (Quintals)
4.2.5 11:3:6
:3:6 (1
(1 cement :: 3 3 coarse sand derived from
natural sources :: 6 6 graded stone aggregate 20 20 2.20
mm
mm nominal size derived
nominal size derived from
from natural sources)
natural sources) cum
CUITI

4.2.5A (1 cement:
1:3:6 (1 cement :3 3 manufactured sand derived
from Recycled
from Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA) :: 6 6
graded stone aggregate 20 mm nominal size
20 mm
derived from Recycled Concrete Aggregate
(RCA))
(RCA)) cum
CUITI 2.20
4.2.5B (1 cement:
1:3:6 (1 cement : 3 3 manufactured sand derived
from Recycled
from Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA) :: 6 6
graded stone aggregate 20 mm nominal size
20 mm
derived from Recycled
derived from Aggregate (RA))
Recycled Aggregate (RA)) cum
CUM 2.20
4.2.8 11:5:10
:5:10 (1
(1 cement:
cement : 55 coarse sand derived from
natural sources: 10
10 graded stone aggregate 40 40 1.30
mm
mm nominal size derived
nominal size derived from
from natural
natural sources)
sources) cum
CUITI

4.2.8A (1 cement
1:5:10 (1 cement:5: 5 manufactured sand derived
from Recycled
from Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA):: 10
10
graded stone aggregate 40 mm nominal size
40 mm
derived from Recycled
derived from Aggregate (RA))
Recycled Aggregate (RA)) cum
CUITI 1.30
4.4 P/L cement concrete in kerbs, steps etc.:
4.4.1
4.4.1 (1 cement:
1:1.5:3 (1 1.5 coarse sand derived from
cement : 1.5
natural sources :: 3 3 graded stone aggregate 20 20
mm
mm nominal size derived
nominal size derived from
from natural
natural sources)
sources) cum
CUITI 4.00
4.4.1A (1 cement
1:1.5:3 (1 cement:: 1.5
1.5 inlcuding manufactured
sand derived from Recycled Concrete Aggregate
(RCA)
(RCA) upto 25%::33 graded
upto 25% graded stone aggregate 20
stone aggregate 20
mm nominal size derived from Recycled Concrete
mm
Aggregate (RCA)
Aggregate (RCA) upto 25%
upto 25% cum
CUM 4.00
CEMENT CONCRETE (PRE-CAST)
4.5
4.5 P/Lprecast
P/L precast cement concrete string or
or lacing courses, copings
etc.:
4.5.1
4.5.1 11:1½:3
:1’/z:3 (1
(1 cement:1½
cement:1’/z coarse sand derived from
natural sources:3 graded stone aggregate 20 mm
20 mm
nominal size derived
nominal size from natural
derived from natural sources)
sources)
cum
cum 4.05
4.5.1A 1:1’/:3 (1
1:1½:3 (1 cement:1’/
cement:1½ inlcuding manufactured
sand derived from Recycled Concrete Aggregate
(RCA)
(RCA) upto
upto 25%
25% ::33 graded
graded stone aggregate 20
stone aggregate 20
mm nominal size derived from Recycled Concrete
mm
Aggregate (RCA)
Aggregate (RCA) upto 25%)
upto 25%) cum
cum 4.05
4.6
4.6 P/Lprecast
P/L precast cement concrete in kerbs, edgings etc.:
4.6.1
4.6.1 1:1.5:3((11 cement
1:1.5:3 cement:: 1.5
1.5coarse
coarse sand derived from
natural sources :: 33 graded stone aggregate 20 20
mm
mm nominal size derived
nominal size from natural
derived from natural sources)
sources) cum
cum 4.05
4.6.1A 1:1.5:3(( 11 cement
1:1.5:3 cement:: 1.5
1.5 inlcuding manufactured
sand derived from Recycled Concrete Aggregate
(RCA)
(RCA) upto 25% ::33 graded
upto 25% graded stone
stone aggregate
aggregate 20
20
mm nominal size derived from Recycled Concrete
mm
Aggregate (RCA)
Aggregate (RCA) upto 25%)
upto 25%) cum
cum 4.05

386
386 FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 4.0 CONCRETE
CONCRETE WORK
WORK
Code Description Unit Quantity of cement
No.
No. perunit
per unit quantity of
work (Quintals)
4.7 P/L precast cement concrete solid blocks:
4.7.1
4.7.1 (1 cement:
1:1.5:3 (1 1.5 coarse sand derived from
cement : 1.5
natural sources :: 3 3 graded stone aggregate 20 20
mm
mm nominal size derived
nominal size derived from
from natural sources)
natural sources)
cum
CUM 4.56
4.7.1A (1 cement
1:1.5:3 (1 cement:: 1.5
1.5 inlcuding manufactured
sand derived from Recycled Concrete Aggregate
(RCA)
(RCA) upto 25% ::33 graded
upto 25% graded stone
stone aggregate
aggregate 20
20
mm nominal size derived from Recycled Concrete
mm
Aggregate (RCA)
Aggregate (RCA) upto 25%))
upto 25% cum
cum 4.56
4.8 P/L precast cement concrete hollow blocks:
4.8.1
4.8.1 (1 cement:
1:1.5:3 (1 1.5 coarse sand derived from
cement : 1.5
natural sources ::33 graded stone aggregate 20 20
mm
mm nominal size derived
nominal size derived from
from natural
natural sources
sources)) cum
CUM 2.899
4.8.1A (1 cement:
1:1.5:3 (1 1.5 inlcuding manufactured
cement : 1.5
sand derived from Recycled Concrete Aggregate
(RCA)
(RCA) upto
upto 25%
25% ::33 graded
graded stone
stone aggregate
aggregate 20
20
mm nominal size derived from Recycled Concrete
mm
Aggregate (RCA)
Aggregate (RCA) upto 25%)
upto 25%) cum
CUM 2.899
4.9
4.9 and placing in position 125
Precasting and 125 mm
mm dia Bollards 600
600 mm
mm
high...... cement concrete 1:3:6 (1
high…. (1 Cement
Cement:3 : 3 coarse sand (zone-
III) derived from
III) derived from natural
natural sources
sources::6 6 graded
graded stone aggregate 20
stone aggregate 20
mm
mm nominal size derived
nominal size derived from
from natural sources)…..
natural sources)..... each 0.097
4.9A and placing in position 125
Precasting and 125 mm
mm dia Bollards 600
600 mm
mm
high...... cement concrete
high…. concrete11:3:6
:3:6 (1
(1 Cement
Cement:3 : 3 manufactured
sand derived from
sand derived from Recycled
Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA) :: 66
graded stone aggregate 20 20 mm
mm nominal size derived from
Recycled
Recycled Concrete Aggregate (RCA))…..
Concrete Aggregate (RCA)).....
each 0.097
4.9B and placing in position 125
Precasting and 125 mm
mm dia Bollards 600
600 mm
mm
high...... cement concrete
high…. concrete11:3:6
:3:6 (1
(1 Cement
Cement:3
: 3 manufactured
sand derived from
sand derived from Recycled
Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA) :: 66
graded stone aggregate 20 20 mm
mm nominal size derived from
Recycled Aggregate (RA))…..
Recycled Aggregate (RA))..... each 0.097
DAMP- PROOF COURSE
4.10 P/L D.P.C. 40 mm thick with C.C. (1
40 mm (1 cement :2 coarse sand
derived from natural sources :4 graded stone aggregate 12.5mm
nominal size derived
nominal size from natural
derived from natural sources).
sources).
sqm
sqm 0.13
4.10A P/L D.P.C. 40
P/L mm thick with C.C. (1
40 mm (1 cement :2 inlcuding
manufactured sand derived from Recycled Concrete Aggregate
(RCA)
(RCA) upto
upto 25%
25% :4 graded stone
:4 graded stone aggregate
aggregate 12.5mm
12.5mm nominal
nominal
size
size derived from Recycled
derived from Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto
upto
25%).
25%). sqm
sqm 0.13
4.11
4.11 P/L D.P.C. 50
P/L 50 mm
mm thick with C.C. (1(1 cement :2 coarse sand
derived from natural sources :4 graded stone aggregate 12.5mm
nominal size derived
nominal size from natural
derived from natural sources).
sources).
sqm
sqm 0.16

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 4.0 CONCRETE
CONCRETE WORK
WORK 387
387
Code Description Unit Quantity of cement
No.
No. perunit
per unit quantity of
work (Quintals)
4.11A P/L D.P.C. 5050 mm
mm thick with C.C. (1 (1 cement :2 inlcuding
manufactured sand derived from Recycled Concrete Aggregate
(RCA)
(RCA) upto 25% :4
upto 25% :4 graded stone aggregate
graded stone aggregate 12.5mm
12.5mm nominal
nominal
size derived from
size derived from Recycled Concrete Aggregate
Recycled Concrete Aggregate (RCA)
(RCA) upto
upto
25%).
25%). sqm
sqm 0.16
MISCELLANEOUS
4.17 50 mm
Making plinth protection 50 mm thick of cement concrete1 :3
concrete 1:3
coarse sand (zone-III)
coarse sand derived from
(zone-III) derived from natural sources : 6 graded
natural sources:6 graded
stone aggregate 20 mm nominal size derived from natural
20 mm
sources)
sources) sqm
sqm 0.11
0.11
4.17A 50 mm
Making plinth protection 50 mm thick of cement concrete1
concrete 1:3:3
manufactured sand derived from Recycled Concrete Aggregate
(RCA)
(RCA):6: 6 graded
graded stone aggregate 20
stone aggregate 20 mm
mm nominal
nominal size derived
size derived
from Recycled
from Recycled Concrete Aggregate (RCA))
Concrete Aggregate (RCA)) sqm
sqm 0.11
0.11
4.17B 50 mm
Making plinth protection 50 mm thick of cement concrete1
concrete 1:3:3
manufactured sand derived from Recycled Concrete Aggregate
(RCA)
(RCA):6: 6 graded
graded stone aggregate 20
stone aggregate 20 mm
mm nominal
nominal size derived
size derived
from Recycled
from Aggregate (RA))
Recycled Aggregate (RA)) sqm
sqm 0.11
0.11
4.20 P/L ready mix plain cement concrete derived from natural
sources
4.20.1
4.20.1 All works upto plinth level
4.20.1.1
4.20.1.1 Concrete of M10 grade with minimum cement
of M10
content of 220
220 kg /cum cum
CUM 2.20
4.20.1.2 Concrete of M15 grade with minimum cement
of M15
content of 240
240 kg /cum cum
CUM 2.40
4.20.1.3 Concrete of M20 grade with minimum cement
of M20
content of 270
270 kg /cum cum
cum 2.70
4.20.1.4 Concrete of M25 grade with minimum cement
of M25
content of 300
300 kg /cum cum
CUM 3.00
4.20.2 All works
All works above
above plinth
plinth and
and upto floor V level
upto floorV level
4.20.2.1
4.20.2.1 Concrete of M10 grade with minimum cement
of M10
of 220
content of 220 kg /cum cum
cum 2.20
4.20.2.2 Concrete of M15 grade with minimum cement
of M15
of 240
content of 240 kg /cum cum
CUM 2.40
4.20.2.3 Concrete of M20 grade with minimum cement
of M20
content of 270
270 kg /cum cum
cum 2.70
4.20.2.4 Concrete of M25 grade with minimum cement
of M25
of 300
content of 300 kg /cum cum
cum 3.00
4.20A P/L ready mix plain cement concrete derived from natural
P/L
sources
sources&& Recycled
Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA)
4.20A.1
4.20A.1 All works upto plinth level
4.20A.1.1
4.20A.1.1 Concrete of M10 grade with minimum cement
of M10
of 220
content of 220 kg /cum cum
cum 2.20
4.20A.1.2 Concrete of M15 grade with minimum cement
of M15
of 240
content of 240 kg /cum cum
cum 2.40
4.20A.1.3 Concrete of M20 grade with minimum cement
of M20
of 270
content of 270 kg /cum cum
CUM 2.70

388
388 FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 4.0 CONCRETE
CONCRETE WORK
WORK
Code Description Unit Quantity of cement
No.
No. perunit
per unit quantity of
work (Quintals)
4.20A.1.4 Concrete of M25 grade with minimum cement
of M25
of 300
content of 300 kg /cum cum
cum 3.00
4.20A.2 All works
All works above
above plinth
plinth and
and upto floor V level
upto floorV level
4.20A.2.1
4.20A.2.1 Concrete of M10 grade with minimum cement
of M10
of 220
content of 220 kg /cum cum
CU M 2.20
4.20A.2.2 Concrete of M15 grade with minimum cement
of M15
of 240
content of 240 kg /cum cum
CU M 2.40
4.20A.2.3 Concrete of M20 grade with minimum cement
of M20
of 270
content of 270 kg /cum cum
CU M 2.70
4.20A.2.4 Concrete of M25 grade with minimum cement
of M25
of 300
content of 300 kg /cum cum
CU M 3.00

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 4.0 CONCRETE
CONCRETE WORK
WORK 389
389
1.0COEFFICIENTS
1.0 FOR CEMENT CONSUMPTION
COEFFICIENTS FOR
5.0REINFORCED CEMENT CONCRETE
5.0

Code Description Unit Quantity of cement


No.
No. perunit
per unit quantity of
work (Quintals)
CAST-IN-SITU
5.1
5.1 P/L R.C.C. upto plinth level
P/L level::
5.1.2 (1 cement:
1:1.5:3 (1 1.5 coarse sand derived from
cement : 1.5
sources:33 graded stone aggregate 20
natural sources: mm
20 mm
nominal size derived
nominal size derived from
from natural sources)
natural sources) cum
cum 4.00
5.1.2A (1 cement :: 1.5
1:1.5:3 (1 1.5 coarse sand including
manufactured sand derived from Recycled
Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto
upto 20%:
20%:33 graded
graded
stone aggregate 20 mm nominal size derived from
20 mm
Recycled
Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 20%)
upto 20%) cum
cum 4.00
5.1.3 (1 cement :: 2 2 coarse sand derived from
1:2:4 (1
sources:44 graded stone aggregate 20
natural sources: mm
20 mm
nominal size derived
nominal size from natural
derived from natural sources)
sources) cum
CUM 3.2
5.1.3A (1 cement :: 22 coarse sand including
1:2:4 (1
manufactured sand derived from Recycled
Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto
upto 20%:
20%:44 graded
graded
stone aggregate 20 mm nominal size derived from
20 mm
Recycled
Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 20%)
upto 20%) cum
CUITI 3.2
5.2
5.2 R.C.C work in walls etc.:
5.2.2 (1 cement:
1:1.5:3 (1 1.5 coarse sand derived from
cement : 1.5
natural sources:3
sources: 3 graded stone aggregate 20 mm
20 mm
nominal size derived
nominal size from natural
derived from natural sources)
sources) cum
CUM 4.00
5.2.2A (1 cement :: 1.5
1:1.5:3 (1 1.5 coarse sand including
manufactured sand derived from Recycled
Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto
upto 20%:
20%:33 graded
graded
stone aggregate 20 mm nominal size derived from
20 mm
Recycled
Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 20%)
upto 20%) cum
CUM 4.00
5.3
5.3 R.C.C.
R.C.C. (1:1.5
(1:1.5 coarse sand(zone-III) derived
coarse sand(zone-III) derived from
from natural sources
natural sources
:33 graded stone aggregate 20 20 mm
mm nominal size derived from
natural
natural sources) work in
sources) work in beams etc.
beams etc. cum
CUM 4.00
5.3A R.C.C. (1:1.5 including manufactured sand derived from
Recycled
Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 20%: 3 graded
upto 20%:3 graded stone
stone
aggregate 20 mm nominal size derived from Recycled Concrete
20 mm
Aggregate (RCA)
Aggregate (RCA) upto 20%) work
upto 20%) work in
in beams
beams etc.
etc. cum
CUM 4.00
5.4
5.4 R.C.C.
R.C.C. (1:1.5
(1:1.5 coarse sand(zone-III) derived
coarse sand(zone-III) derived from
from natural sources
natural sources
:33 graded stone aggregate 20 20 mm
mm nominal size derived from
natural
natural sources) work in
sources) work in kerbs,
kerbs, steps etc.
steps etc. cum
CUITI 4.00
5.4A R.C.C. (1:1.5 including manufactured sand derived from
Recycled
Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 20%:3: 3 graded
upto 20% graded stone
stone
aggregate 20 mm nominal size derived from Recycled Concrete
20 mm
Aggregate (RCA)
Aggregate (RCA) upto 20%) work
upto 20%) work in
in kerbs, steps etc.
kerbs, steps etc. cum
cum 4.00
5.5
5.5 R.C.C.
R.C.C. (1:1.5
(1:1.5 coarse sand(zone-III) derived
coarse sand(zone-III) derived from
from natural sources
natural sources
:33 graded stone aggregate 20 20 mm
mm nominal size derived from
natural sources) work
natural sources) work in
in arches,domes etc.
arches,domes etc. cum
CUM 4.00

390
390 FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 5.0 REINFORCED CEMENT
CEMENT CONCRETE
CONCRETE
Code Description Unit Quantity of cement
No.
No. perunit
per unit quantity of
work (Quintals)
5.5.A R.C.C. (1:1.5 including manufactured sand derived from
Recycled
Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto
upto 20%:
20%:33 graded
graded stone
stone
aggregate 20 mm nominal size derived from Recycled Concrete
20 mm
Aggregate (RCA)
Aggregate (RCA) upto 20%) work
upto 20%) work in
in arches,domes etc.
arches,domes etc. cum
CUITI 4.00
5.6
5.6 R.C.C.
R.C.C. (1:1.5 coarse sand(zone-III)
(1:1.5 coarse sand(zone-III) derived
derived from
from natural sources
natural sources
.:33 graded stone aggregate 20 20 mm
mm nominal size derived from
natural sources) work
natural sources) work in
in chimneys
chimneys&& shafts.
shafts. cum
CUITI 4.00
5.6A R.C.C. (1:1.5 including manufactured sand derived from
Recycled
Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto
upto 20%:
20%:33 graded
graded stone
stone
aggregate 20 mm nominal size derived from Recycled Concrete
20 mm
Aggregate (RCA)
Aggregate (RCA) upto 20%) work
upto 20%) work in
in chimneys
chimneys&& shafts.
shafts. cum
CUITI 4.00
5.7
5.7 R.C.C.
R.C.C. (1:1.5coarse
(1 :1.5coarse sand(zone-III) derived from
sand(zone-III) derived from natural sources
natural sources
:33 graded stone aggregate 20 20 mm
mm nominal size derived from
natural
natural sources) work in
sources) work well-steining.
in well-steining. cum
CUITI 4.00
5.7A R.C.C. (1:1.5 including manufactured sand derived from
Recycled
Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto
upto 20%:
20%:33 graded
graded stone
stone
aggregate 20 mm nominal size derived from Recycled Concrete
20 mm
Aggregate (RCA)
Aggregate (RCA) upto 20%) work
upto 20%) work in well-steining.
in well-steining. cum
CUM 4.00
5.8
5.8 R.C.C.
R.C.C. (1:1.5coarse
(1 :1.5coarse sand(zone-III) derived from
sand(zone-III) derived from natural sources
natural sources
:33 graded stone aggregate 20 20 mmmm nominal size derived from
natural sources) work
natural sources) work in vertical and
in vertical and horizontal fins individually
horizontal fins individually
or forming box
box louvers, facias and
and eaves boards. cum
CUM 4.00
5.8A R.C.C. (1:1.5 including manufactured sand derived from
Recycled
Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA) uptoupto 20%:
20%:33 graded
graded stone
stone
aggregate 20 mm nominal size derived from Recycled Concrete
20 mm
Aggregate (RCA)
Aggregate (RCA) upto 20%) work
upto 20%) work in vertical and
in vertical and horizontal fins
horizontal fins
individually or forming box
box louvers, facias and and eaves boards. cum
cum 4.00
PRE - CAST R.C.C.
PRE
5.12 P/F
P/F precast
precast R.C.C.
R.C.C. (1:1.5
(1:1.5 coarse sand (zone-III)
coarse sand derived from
(zone-III) derived from
natural sources:3
sources : 3 graded stone aggregate 20 mm nominal size
20 mm
derived from
derived from natural sources) work
natural sources) work in string courses,
in string courses, bands,
bands,
bed plates, anchor blocks, plain window sills etc.
copings, bed cum
CUM 4.00
5.12A (1 :1.5 including manufactured sand derived
P/F precast R.C.C. (1:1.5
from Recycled
from Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 20%::3 3 graded
upto 20% graded
stone aggregate 20
20 mm
mm nominal size derived from Recycled
Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 20%) work
upto 20%) work in
in string courses,
string courses,
bed plates, anchor blocks, plain window sills
bands, copings, bed
etc. cum
CUM 4.00
5.13 P/F
P/F precast
precast R.C.C.
R.C.C. (1:1.5
(1:1.5 coarse sand (zone-III)
coarse sand derived from
(zone-III) derived from
natural sources:
sources : 33 graded stone aggregate 20 20 mmmm nominal
size derived
size derived from
from natural sources) in
natural sources) small lintels
in small lintels not exceeding
not exceeding
1.5m clear span. cum
CUITI 4.00
5.13A (1 :1.5 including manufactured sand derived
P/F precast R.C.C. (1:1.5
from Recycled
from Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 20%::3 3 graded
upto 20% graded
stone aggregate 20 20 mm
mm nominal size derived from Recycled
Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 20%) in
upto 20%) small lintels
in small lintels not
not
exceeding 1.5m clear span. cum
cum 4.00
5.14 P/F
P/F precast
precast R.C.C.
R.C.C. (1:1.5
(1:1.5 coarse sand (zone-III)
coarse sand derived from
(zone-III) derived from
natural sources:
sources : 33 graded stone aggregate 20 mm nominal
20 mm
size derived
size derived from
from natural sources) in
natural sources) in mouldings as in
mouldings as in cornices,
cornices,
windows sills etc. cum
CUITI 4.00

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 5.0 REINFORCED CEMENT
CEMENT CONCRETE
CONCRETE 391
391
Code Description Unit Quantity of cement
No.
No. perunit
per unit quantity of
work (Quintals)
5.14A P/F precast R.C.C. (1:1.5 including manufactured sand derived
from Recycled
from Concrete Aggregate
Recycled Concrete Aggregate (RCA)
(RCA) upto
upto 20%20%::3 3 graded
graded
stone aggregate 20 20 mmmm nominal size derived from Recycled
Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 20%) in
upto 20%) in mouldings
mouldings as as inin
cornices, windows sills etc.
cornices, cum
CUM 4.00
5.15 P/F
P/F precast
precast R.C.C.
R.C.C. (1:1.5
(1:1.5 coarse sand (zone-III)
coarse sand derived from
(zone-III) derived from
natural sources:3
sources : 3 graded stone aggregate 20 20 mmmm nominal size
derived from
derived from natural
natural sources)
sources) in in lintels,
lintels, beams
beams and and bressumers
bressumers
etc. cum
CUITI 4.00
5.15A P/F precast R.C.C. (1:1.5 including manufactured sand derived
from Recycled
from Concrete Aggregate
Recycled Concrete Aggregate (RCA)
(RCA) upto
upto 20%20%::3 3 graded
graded
stone aggregate 20 20 mmmm nominal size derived from Recycled
Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 20%) in
upto 20%) in lintels,
lintels, beams
beams andand
bressumers etc. cum
cum 4.00
5.16 P/F
P/F precast
precast R.C.C.
R.C.C. (1:1.5
(1:1.5 coarse sand (zone-III)
coarse sand derived from
(zone-III) derived from
natural sources:3
sources : 3 graded stone aggregate 20 20 mmmm nominal size
derived from
derived from natural sources) in
natural sources) in shelves.
shelves. cum
cum 4.05
5.16A P/F precast R.C.C. (1:1.5 including manufactured sand derived
from Recycled
from Concrete Aggregate
Recycled Concrete Aggregate (RCA)
(RCA) upto
upto 20%20%::3 3 graded
graded
stone aggregate 20 20 mmmm nominal size derived from Recycled
Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 20%) in
upto 20%) shelves.
in shelves. cum
CUITI 4.05
5.17 P/F
P/F precast
precast R.C.C.
R.C.C. (1:1.5
(1:1.5 coarse sand (zone-III)
coarse sand derived from
(zone-III) derived from
natural sources:
sources : 33 graded stone aggregate 20 20 mmmm nominal
size derived
size derived from
from natural
natural sources)
sources) in vertical & horizontal
in vertical& fins
horizontal fins
individually or forming boxbox louvers. cum
CUITI 4.00
5.17A P/F precast R.C.C. (1:1.5 including manufactured sand derived
from Recycled
from Concrete Aggregate
Recycled Concrete Aggregate (RCA)
(RCA) upto
upto 20%20%::3 3 graded
graded
stone aggregate 20 20 mmmm nominal size derived from Recycled
Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 20%) in
upto 20%) vertical & horizontal
in vertical& horizontal
fins individually
fins or forming
individually or forming box
box louvers.
louvers. cum
CUITI 4.00
5.18 Fixing
Fixing precast
precast cement
cement concrete Jali (1:2:4).
concrete Jali (1:2:4).
5.18.1
5.18.1 50 mm
50 mm thick sqm
100 sqm 1.64*“
1.64**
5.18.2 40 mm thick
40 mm 100 sqm
sqm 1.64”*
1.64**
5.18.3 25 mm
25 mm thick 100 sqm
sqm 1.64”
1.64**

** Cement
** for fixing
Cement for fixing only.
only.

ENCASING ROLLED STEEL SECTION


5.19 Encasing rolled steel sections, in beams andand columns, with
cement concrete (1:1.5
cement concrete (1:1.5 coarse sand (zone-III)
coarse sand derived from
(zone-III) derived from
natural sources:3
sources : 3 graded stone aggregate 20 mm nominal size
20 mm
derived from
derived from natural sources).
natural sources). cum
cum 4.00
5.19A Encasing rolled steel sections, in beams and
and columns, with
cement concrete (1:1.5 including manufactured sand derived
from Recycled
from Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 20%::3 3 graded
upto 20% graded
stone aggregate 20 mm nominal size derived from Recycled
20 mm
Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 20%).
upto 20%). cum
CUM 4.00

392
392 FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 5.0 REINFORCED CEMENT
CEMENT CONCRETE
CONCRETE
Code Description Unit Quantity of cement
No.
No. perunit
per unit quantity of
work (Quintals)
5.20 Encasing rolled steel section in grillages with cement concrete
(1:1.5 coarse sand
(1 :1.5 coarse sand (zone-III) derived from
(zone-III) derived from natural
natural sources
sources::33
graded stone aggregate 20 20 mm
mm nominal size derived from
natural
natural sources).
sources). cum
CUITI 4.00
5.20A Encasing rolled steel section in grillages with cement concrete
(1 :1.5 including manufactured sand derived from Recycled
(1:1.5
Concrete Aggregate (RCA)
Concrete Aggregate (RCA) upto 20%:3: 3 graded
upto 20% graded stone
stone aggregate
aggregate
20 mm nominal size derived from Recycled Concrete Aggregate
20 mm
(RCA)
(RCA) upto 20%).
upto 20%). cum
CUITI 4.00
5.23 Smooth finishing of
Smooth finishing of exposed surface of
exposed surface of R.C.C. work with6
R.C.C. work with 6 mm
mm
thick cement
thick cement mortar
mortar (1:3).
(1:3). 100 sqm
sqm 3.67
5.24 Exra for Rendering smooth
Exra forRendering the top of suspended floors,
smooth thetopofsuspended floors, landings
landings
and staircases
and staircases with
with cement
cement mortar
mortar (1:2).
(1:2). 100 sqm
sqm 4.17
5.27 Providing and filling
Providing and filling in
in position
position bitumen
bitumen mix filler.
mix filler. cum
cum 0.032
MIX CONCRETE
DESIGN MIX
5.33 P/L Design mix concrete derived from natural sources. cum
CUITI 3.30***
5.33.1
5.33.1 Upto
Upto Plinth
Plinth level
level
5.33.1.1
5.33.1.1 Concrete of M25 grade with minimum cement
of M25
content of 330
330 kg /cum cum
CUM 3.30
5.33.1.2 Concrete of M30 grade with minimum cement
of M30
content of 350
350 kg /cum cum
CUITI 3.50
5.33.1.3 Concrete of M35 grade with minimum cement
of M35
content of 370
370 kg /cum cum
CUITI 3.70
5.33.1.4 Concrete of M40 grade with minimum cement
of M40
content of 390
390 kg/cum cum
CUM 3.90
5.33.1.5 Concrete of M50 grade with minimum cement
of M50
content of 410
410 kg/cum cum
CUITI 4.10
5.33.2 Above plinth level Plinth level
5.33.2.1
5.33.2.1 Concrete of M25 grade with minimum cement
of M25
content of 330
330 kg /cum cum
CUM 3.30
5.33.2.2 Concrete of M30 grade with minimum cement
of M30
content of 350
350 kg /cum cum
CUM 3.50
5.33.2.3 Concrete of M35 grade with minimum cement
of M35
content of 370
370 kg /cum cum
CUM 3.70
5.33.2.4 Concrete of M40 grade with minimum cement
of M40
content of 390
390 kg/cum cum
CUM 3.90
5.33.2.5 Concrete of M50 grade with minimum cement
of M50
content of 410
410 kg/cum cum
CUM 4.10
5.33A P/L Design mix concrete derived from natural sources with
P/L
permissible
permissible utilization of Recycled
utilization of Recycled Concrete Aggregate (RCA).
Concrete Aggregate (RCA).
5.33A.1
5.33A.1 Upto
Upto Plinth
Plinth level
level
5.33A.1.1
5.33A.1.1 Concrete of M25 grade with minimum cement
of M25
content of 330
330 kg /cum cum
cum 3.30
5.33A.2 Above plinth level Plinth level
5.33A.2.1
5.33A.2.1 Concrete of M25 grade with minimum cement
of M25
of 330
content of 330 kg /cum cum
CUM 3.30

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 5.0 REINFORCED CEMENT
CEMENT CONCRETE
CONCRETE 393
393
Code Description Unit Quantity of cement
No.
No. perunit
per unit quantity of
work (Quintals)
5.36 P/F
P/F precast
precast R.C.C.
R.C.C. in waffle units….
in waffle units.... 1:1½:3
1:1’/:3 (1
(1 Cement
Cement:: 1½
1’/
coarse
coarse sand
sand (zone-III) derived from
(zone-III) derived from natural sources : 3 graded
natural sources:3 graded
stone aggregate 10 mm mm nominal size derived from natural
sources)
sources) cum
CUITI 4.12***
5.36A P/F
P/F precast
precast R.C.C.
R.C.C. in waffle units….
in waffle units.... 1:1½:3
1:1’/:3 (1
(1 Cement
Cement:: 1½
1’/z
including manufactured sand derived from Recycled Concrete
Aggregate (RCA)
Aggregate (RCA) upto 20%:3
upto 20% : 3 graded
graded stone
stone aggregate
aggregate 10
10 mm
mm
nominal
nominal size
size derived from Recycled
derived from Recycled Concrete Aggregate (RCA)
Concrete Aggregate (RCA)
upto 20%)
upto 20%) cum
CUITI 4.12*”
4.12***
”* Actual weight fordesign
*** for design mix will be
be worked out
out taking into
consideration the cement requirement as per particular mixmix
design
5.47.1
5.47.1 P/F factory made precast RCC
P/F RCC M-40 doors&
doors & windows 100 metre 0.381”
0.381**
5.47.2 P/F factory made precast RCC
P/F RCC M-40 doors&
doors & windows 100 metre 0.381**
5.47.3 P/F factory made precast RCC
P/F RCC M-40 doors&
doors & windows 100 metre 0.381**
5.48 and laying RCC
Providing and RCC for construction of piers abutments
portal frames etc. cum
CUM 4.80
5.49 RCC diaphram wall by
Constructing cast insitu RCC by providing …..
..... cum. 4.41
4.41

** Cement
** for fixing
Cement for fixing only.
only.

394
394 FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 5.0 REINFORCED CEMENT
CEMENT CONCRETE
CONCRETE
FOR CEMENT CONSUMPTION
1.0 COEFFICIENTS FOR
6.0MASONRY WORK
6.0 WORK

Code Description Unit Quantity of cement


No.
No. perunit
per unit quantity of
work (Quintals)
6.1 Brick work in foundation&
foundation & plinth with non
non modular bricks.
bricks.
6.1.1
6.1.1 Cement
Cement mortar
mortar 1:4
1:4 (1 cement : 4 coarse
(1 cement:4 coarse sand)
sand) cum 0.95
6.1.2 Cement
Cement mortar
mortar 1:6
1:6 (1 cement :6 6 coarse
(1 cement: coarse sand)
sand) cum 0.625
6.2
6.2 Brick work in foundation&
foundation & plinth with modular bricks.
bricks.
6.2.1
6.2.1 Cement
Cement mortar
mortar 1:4
1:4 (1 cement : 4 coarse
(1 cement:4 sand)
coarse sand) cum
cum 0.836
6.2.2 Cement
Cement mortar
mortar 1:6
1:6 (1 cement :6 6 coarse
(1 cement: sand)
coarse sand) cum
cum 0.55
6.3
6.3 Brick work with machine moulded perforated bricks.
bricks.
6.3.1
6.3.1 With non
non modular bricks. cum 0.625
6.3.2 With modular bricks. cum 0.55
6.4
6.4 Brick work in superstructure
6.4.1
6.4.1 Cement
Cement mortar
mortar11:4
:4 (1 cement : 4 coarse
(1 cement:4 sand)
coarse sand) cum
cum 0.95
6.4.2 Cement
Cement mortar
mortar11:6
:6 (1 cement :6 6 coarse
(1 cement: sand)
coarse sand) cum
cum 0.625
6.7 Half
Half brick
brick masonry
masonry in
in cement
cement mortar
mortar (1:3) for closing
(1:3) for closing cavity5
cavity 5
to 7.5
7.5 cm
cm wide in cavity wall. 100 metre
100 3.86
6.8
6.8 Brick work 7 cm
Brick work7 cm in cement mortar
in cement mortar (1:3).
(1:3). 100 sqm
100 sqm 9.23
6.9
6.9&& 6.10 Brick work in
Brick work in plain
plain&& gauged
gauged arches
arches in
in cement
cement mortar
mortar (1:3).
(1:3). UT
Ccum 1.28
HALF BRICK MASONRY
6.12&& 6.13
6.12 Half brick masonry in foundations&
foundations & plinth and
and superstructure.
6.12.1&&
6.12.1 Cement
Cement mortar
mortar 1:3
1:3 (1 cement :3 3 coarse
(1 cement: sand)
coarse sand)
6.13.1
6.13.1 100 sqm
100 sqm 14.28
6.12.2&&
6.12.2 Cement
Cement mortar
mortar 1:4
1:4 (1 cement : 4 coarse
(1 cement:4 coarse sand)
sand)
6.13.2 100 sqm
100 sqm 10.64
BRICK TILE WORK
6.16 Tile brick masonry in foundation and plinth.::
and plinth.
6.16.1
6.16.1 Cement
Cement mortar
mortar 1:4
1:4 (1 cement : 4 coarse
(1 cement:4 sand)
coarse sand) cum
cum 1.52
6.16.2 6.16.2 Cement
Cement mortar
mortar 1:6
1:6 (1 cement :6 6 coarse
(1 cement: sand)
coarse sand) cum
CUlTl 1.00
6.17&& 6.18
6.17 Tile brick masonry with m/c
m/c moulded tiles in cement mortar
1:6
1:6 (1 cement :6 6 coarse
(1 cement: coarse sand).
sand). cum
cum 1.00
6.20&& 6.21
6.20 6.21 Tile brick masonry with tile bricks in plain/gauged arches
work in
work cement mortar
in cement mortar (1:4).
(1 :4). cum
cum 1.33
6.22 TTile
ile brick
brick masonry work 5 cm
masonry work5 cm thick
thick in cement mortar
in cement mortar (1:3).
(1:3). 100 sqm
100 sqm 7.65
HONEY COMB WORK
WORK
6.23 Honey-comb brick work 10/11.4 cm
cm thick in cement mortar
1:4. 100sqm
100 sqm 6.56
EXPOSED BRICK WORK
6.26 Brick work with
Brick work with selected
selected bricks
bricks in cement mortar
in cement mortar (1:6).
(1 :6). cum
cum 0.625
6.27 Brick work with
Brick work with modular
modular bricks
bricks in
in cement
cement mortar
mortar (1:6).
(1:6). cum
cum 0.55

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 6.0 MASONRY
MASONRY WORK
WORK 395
395
Code Description Unit Quantity of cement
No.
No. perunit
per unit quantity of
work (Quintals)
6.28 Brick work with machine moulded modular bricks in cement
mortar
mortar (1:6).
(1:6). cum
CUM 0.55
6.29 Brick work with m/c
m/c moulded F.P.S. bricks in cement mortar
(1:6).
(1:6). cum
cum 0.625
6.30 Brick work with machine moulded perforated F.P.S. bricks in
cement
cement mortar
mortar (1:6).
(1:6). cum
CUM 0.625
6.31
6.31 Brick work with machine moulded perforated modular bricks
in
in cement
cement mortar
mortar (1:6).
(1:6). cum
cum 0.55
6.32 Brick work with
Brick work with clay flyash F.P.S.
clay flyash F.P.S. brick
brick
6.32.1
6.32.1 Cement
Cement mortar
mortar11:4
:4 (1 cement : 4 coarse
(1 cement:4 sand)
coarse sand) cum
cum 0.95
6.32.2 Cement
Cement mortar
mortar11:6
:6 (1 cement :6 6 coarse
(1 cement: sand)
coarse sand) cum
CUlTl 0.625
6.34 Brick work with
Brick work with non
non modular fly ash
modular fly ash bricks
bricks in
in
6.34.1
6.34.1 Cement
Cement mortar
mortar11:4
:4 (1 cement : 4 coarse
(1 cement:4 coarse sand)
sand) cum 0.95
6.34.2 Cement
Cement mortar
mortar11:6
:6 (1 cement :6 6 Coarse
(1 cement: sand)
Coarse sand) cum 0.625
6.35 Brick work with modular calcium silicate bricks machine
moulded in
6.35.1
6.35.1 Cement
Cement mortar
mortar 1:4
1:4 (1 cement : 4 coarse
(1 cement:4 sand)
coarse sand) cum
cum 0.836
6.35.3 Cement
Cement mortar
mortar 1:6
1:6 (1 cement :6 6 Coarse
(1 cement: Coarse sand)
sand) cum
CUlTl 0.55
6.36 Brick work with
Brick work with modular extruded burnt
modular extruded fly ash
burnt fly ash clay
clay sewer
sewer
in: :
bricks in
6.36.1
6.36.1 Cement
Cement Mortar
Mortar11:4
:4((11 cement:4
cement : 4 coarse
coarse sand)
sand) lJm
Ccum 0.836
6.37 Brick work with
Brick work with modular extruded burnt
modular extruded fly ash
burnt fly ash clay
clay sewer
sewer
bricks
bricks in cement mortar
in cement mortar (1:3).
(1:3). cum
cum 1.275
6.38 Autoclaved aerated cement blocks masonry with 100mm
thick AAC
thick AAC blocks
blocks in
in cement
cement mortar
mortar (1:4).
(1:4). CUM
cum 0.57
6.44 Brick
Brick edging
edging77 cm wide in
cm wide in cement
cement mortar
mortar (1:4).
(1:4). 100 metre
100 0.137
6.45 Half
Half brick
brick masonry with non
masonry with non modular fly ash
modular fly ash bricks.
bricks.
6.45.1
6.45.1 Cement
Cement mortar
mortar 1:3
1:3 (1 cement :3
(1 cement :3 coarse sand).
coarse sand). 100 sqm
100 sqm 14.28
6.45.2 Cement
Cement mortar
mortar 1:4
1:4 (1 cement :4
(1 cement :4 coarse sand).
coarse sand). 100 sqm
100 sqm 10.64

396
396 COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
FOR CEMENT S.H.:: 6.0 MASONRY
MASONRY WORK
WORK
FOR CEMENT CONSUMPTION
1.0 COEFFICIENTS FOR
7.0
7.0 STONE WORK

Code Description Unit Quantity of cement


No.
No. perunit
per unit quantity of
work (Quintals)
RANDOM RUBBLE MASONRY
7.1
7.1 7.2 Random
&& 7.2 Random rubble
rubble masonry with cement
masonry with cement mortar
mortar (1:6).
(1:6). cum
cum 0.825
COURSED RUBBLE MASONRY
7.6
7.6 Coursed
Coursed rubble
rubble masonry
masonry (first sort) with:
(first sort) with :
7.6.1
7.6.1 Cement mortar
Cement mortar 1:6
1:6 (1 cement :6 6 coarse
(1 cement: coarse sand)
sand) cum
CUM 0.750
7.7
7.7 Coursed
Coursed rubble
rubble masonry
masonry (second
(second sort) with :
sort) with:
7.7.1
7.7.1 Cement mortar
Cement mortar 1:6
1:6 (1 cement :6 6 coarse
(1 cement: sand)
coarse sand) cum
CUM 0.750
ASHLAR MASONRY
7.12 Stone work in
Stone work in plain ashlar in
plain ashlar cement mortar
in cement mortar (1:6)
(1 :6) including
including
pointing with white
pointing with white cement
cement mortar
mortar (1:2).
(1 :2). cum
CUM 0.54
7.13&&
7.13 Stone work plain ashlar in arches/domes in cement mortar
7.14 (1:3)
(1:3) including
including pointing with white
pointing with white cement
cement mortar
mortar (1:2).
(1:2). cum
CUM 1.07
7.15 Stone work ashlar
Stone work ashlar punched
punched in cement mortar
in cement mortar 1:6)
1:6) including
including
pointing with white
pointing with white cement
cement mortar
mortar (1:2).
(1:2). cum
cum 0.54
SUNK, MOULDED, CARVED ASHLAR MASONRY
7.20 Stone work sunk and/
and / ormoulded
or moulded including pointing with white
cement
cement mortar
mortar (1:2).
(1:2). cum
cum 0.54
MISCELLANEOUS STONE WORK
7.26 P/F stone dowels
P/F stone dowels 10x5x2.50
10x5x2.50 cm
cm in cement mortar
in cement mortar (1:2)
(1 :2).. each 0.007
7.28 P/F sloping chajja of stone 40 mm thick and
40 mm and upto 80 cm wide in
80 cm
cement
cement mortar
mortar (1:4)
(1:4) including
including pointing
pointing in white cement
in white cement mortar
mortar
(1:2).
(1 :2). sqm
100 sqm 5.59
7.29 P/F horizontal chajja of stone 40 mm thick and
40 mm and upto 8080 cm
cm
projection
projection in
in cement
cement mortar
mortar (1:4)
(1 :4) including
including pointing
pointing in white
in white
cement
cement mortar
mortar (1:2).
(1:2). sqm
100 sqm 4.94 +
4.94 + 0.03*
0.03*
7.30 30 mm
P/F 30 mm red sand stone sun-shade with cement mortar 1:4
1:4
including finishing complete.
including finishing complete. sqm
100 sqm 2.19
7.31
7.31 Providing and fixing
Providing and fixing red sand stone
red sand stone brackets
brackets 55x22.5x45cm.
55x22.5x45cm. 100nos 3.02
7.32 Stone work, plain in copings, cornices, string courses etc. in
1:6 including pointing with white cement mortar
Cement mortar 1:6
(1:2).
(1 :2). cum
cum 0.54
7.38 Stone tile work forwall
for wall lining with 12
12 mm
mm thick bed
bed in cement
mortar
mortar (1:3).
(1:3). sqm
sqm 10.44
10.44++ 1.70*
1.70*
* * White cement

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 7.0 STONE
STONE WORK
WORK 397
397
1.0COEFFICIENTS
1.0 FOR CEMENT CONSUMPTION
COEFFICIENTS FOR
8.0CLADDING WORK
8.0

Code Description Unit Quantity of cement


No.
No. perunit
per unit quantity of
work (Quintals)
8.1 Marble work 18 mmmm thick for wall lining in cement mortar 1:3
1:3
including pointing with white cement mortar 1:2. 100 sqm
100 sqm 8.67
8.67++ 1.70*
1.70*
8.2
8.2 P/F 18mm thick gang saw
P/F cutmirror
saw cut mirror polished premoulded andand
prepolished)
prepolished) machine
machine cut for kitchen platforms,
cutforkitchen vanity counters
platforms, vanity counters
etc. laid over 20mm thick base cement mortar 1:4. 100 sqm
100 sqm 9.12
8.4
8.4 Extra for fixing
Extra for fixing marble /granite stone
marble /granite over and
stone over and above
above
corresponding basic item, in facia and
and drops ofwidth 150
of width upto 150
mm with epoxy resin based adhesive including cleaning etc.
mm
complete. 100 metre
100 1.27
8.7 P/F cramps in RCC/ CC
P/F CC backing with cement mortar
mortar11:2.
:2.
8.7.1
8.7.1 Gunmetal cramps kg 0.0635
8.7.2 Stainless steel cramps kg 0.0701
0.0701
8.9
8.9 Stone tile work forwall
for wall lining over 12mm thick bed
bed of cement
mortar
mortar (1:3)
(1:3) and
and cement
cement slurry
slurry@@ 3.3
3.3 kg/sqm
kg/sqm including
including pointing
pointing
in white cement complete. 100 sqm
sqm 10.44
10.44++ 1.90*
1.90*
8.11
8.11 P/F machine cut
P/F cutmirror/edge
mirror/edge polished 100 sqm. 8.16
8.16++ 3.30*
3.30*
8.14 Stone work (machine
Stone work (machine cut edges) forwall
cut edges) for wall lining etc. (veneer
lining etc. (veneer
work) in
work) in cement
cement mortar
mortar (1:3)
(1:3) including
including pointing
pointing in white cement
in white cement
mortar
mortar (1:2).
(1:2). 100 sqm
sqm 9.18
9.18++ 1.56*
1.56*
8.15 P/F stainless steel cramps in stone wall lining in cement mortar
(1:2).
(1 :2). kg 0.07
8.16 P/F copper pins 7.5 cm
cm long
long66 mm
mm diameter in stone wall lining
in cement mortar
in cement mortar (1:2).
(1 :2). each 0.007
8.17 Wall lining butch work with Dholpur stone 40 mm thick, in
40 mm
cement
cement mortar
mortar (1:3)
(1:3) including
including ruled
ruled pointing
pointing in
in cement
cement mortar
mortar
(1:2).
(1 :2). sqm
100 sqm 15.50
15.50 +1.70*
-r1.70*
8.18 Stone work ( machine
Stone work( machine cut edges) forwall
cutedges) for wall lining with grout
lining with grout of
of
12
12 mm thick in
mm thick in cement
cement mortar
mortar (1:3) and jointed
(1:3) and jointed with
with Cement
Cement
mortar
mortar (1:2).
(1:2). 100 sqm
sqm 13.744
8.21
8.21 P/F structural steel
P/F structural frame (for
steel frame (for dry
dry stone
stone cladding) embedded in
cladding) embedded in
brick wall with
brick wall with cement
cement concrete
concrete block
block (1:2:4)
(1 :2:4) 100kg 1.05
8.23 P/F 50x50x50 mm mm 2nd class teak wood plugs in cement mortar
11:3.
:3. 100 nos. 0.01
0.01
8.25 P/F 2nd
2nd class teak wood plain lining with wooden plugs. 100 sqm
100 sqm 0.055
8.31
8.31 P/F 1st quality ceramic glazed wall tiles over 12 mm
P/F mm thick bed
bed
of cement
of cement Mortar
Mortar (1:3) with grey
(1:3) with grey cement slurry @ 3.3kg/sqm
cement slurry@ 3.3kg/sqm sqm
sqm 0.1044

*”White
White cement

398
398 COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
FOR CEMENT S.H.:: 8.0 CLADDING
Ci.ADDING WORK
WORK
1.0COEFFICIENTS
1.0 FOR CEMENT CONSUMPTION
COEFFICIENTS FOR
9.0WOOD ANDP.V.C.
9.0 AND P.V.C. WORK

Code Description Unit Quantity of cement


No.
No. perunit
per unit quantity of
work (Quintals)

MISCELLANEOUS
MISCELLANEOUS -- WOOD
WOOD WORK
WORK
9.53
9.53 Providing 40x5 mm
Providing 40x5 flat iron
mm flat iron hold fast 40
hold fast 40 cm
cm long with ce-
long with ce-
ment
ment concrete
concrete block
block 30x10x15cm
30x10x15cm 1:3:6
1:3:6 mix.
mix. 100
100 nos
nos 1.10
1.10 100
100 nos
nos 1.10
1.10

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 9.0 WOOD ANDP.V.C. WORK
AND P.V.C. WORK 399
399
FOR CEMENT CONSUMPTION
1.0 COEFFICIENTS FOR
10.0 STEEL WORK

Code Description Unit Quantity of cement


No.
No. perunit
per unit quantity of
work (Quintals)

10.4 P/F11 mm
P/F mm thick M.S. sheet sliding-shutters with frame. 100 sqm
100 sqm 0.35
10.5 P/F11 mm
P/F mm thick M.S. sheet door with frame. 100 sqm
100 sqm 0.35
10.6 Supplying and fixing
Supplying and fixing rolling
rolling shutters.
shutters. 100 sqm
100 sqm 0.35
10.10.1&&
10.10.1 Fixing standard steel glaze door windows etc. 100 kg
100 kg 0.13
10.11.1
10.11.1
10.13.1
10.13.1 P/F ‘T’ iron froms fordoors
P/F for doors windows&
windows & ventilators 100 kg
100 kg 0.11
0.11
10.15 Providing
Providing and fixing M.S.
and fixing Tubular frames
M.S. Tubular frames fordoors,
for doors, windows,
windows,
ventilators and
and cupboard with 15x3 mm mm lugs 10 10 cm
cm long
embedded in cement concrete blocks 15x10x10 cm cm of
of 1:3:6
mix. 100 kg
100 kg 0.28

400
400 COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
FOR CEMENT S.H.:: 10.0 STEEL WORK
WORK
1.0COEFFICIENTS FOR
1.0 FOR CEMENT CONSUMPTION
11.0 FLOORING

Code Description Unit Quantity of


No.
No. per
cement per
unit quantity of
work (Quintals)
11.1
11.1 Brick
Brick on
on edge flooring.
edge flooring.
11.1.1
11.1.1 1:4
1:4 (1 cement : 4 coarse
(1 cement:4 coarse sand)
sand) sqm
sqm 0.1850
11.1.2 1:6
1:6 (1cement : 6 coarse
(1cement:6 coarse sand)
sand) sqm
sqm 0.1285
11.3 Cement concrete flooring
Cement concrete flooring 1:2:4.
1:2:4.
11.3.1
11.3.1 40mm thick with 20mm nominal size stone aggregate sqm
sqm 0.17
11.4 52
52 mm thick cement
mm thick cement concrete flooring.
concrete flooring. sqm
sqm 0.231
0.231
11.5 62
62 mm thick cement
mm thick cement concrete flooring.
concrete flooring. sqm
sqm 0.263
11.6 Cement
Cement plaster
plaster skirting with cement
skirting with cement mortar
mortar (1:3).
(1:3). sqm
sqm 0.14
11.7 Cement concrete pavement
Cement concrete with C.C.
pavement with C.C. (1:2:4).
(1 :2:4). cum
cum 3.20
TERRAZO FLOORING
11.9 40 mm
40 thick marble
mm thick marble chips flooring with
chips flooring with under
under layer
layer 34
34 mm thick
mm thick
cement
cement concrete
concrete (1:2:4).
(1:2:4).
11.9.1
11.9.1 Dark shade pigment with ordinary cement sqm
sqm 0.1695
11.9.2 Light shade pigment with white cement sqm
sqm 0.129+0.0405*
0.129+0.0405*
11.9.3 Medium shade pigment
Medium shade with 50%
pigment with white cement
50% white and
cement and sqm
sqm 0.1492+0.0202*
0.1492+0.0202*
50% ordinary cement
50% ordinary cement
11.9.4 White cement without any
any pigment sqm
sqm 0.129+0.0202*
0.129+0.0202*
11.9.5 Light shade pigment with ordinary cement sqm
sqm 0.1695
11.9.6 Ordinary cement without any
any pigment sqm
sqm 0.1695
11.10 40 mm
40 thick marble
mm thick marble chips flooring with
chips flooring with under
under layer
layer 31mm thick
31 mm thick
cement concrete 1:2:4.
11.10.1
11.10.1 Dark shade pigment with Ordinary cement sqm
sqm 0.1783
11.10.2 Light shade pigment with white cement sqm
sqm 0.1205+0.0578*
0.1205+0.0578*
11.10.3 Medium shade pigment
Medium shade with 50%
pigment with white cement
50% white and
cement and sqm
sqm 0.1494+0.0289*
0.1494+0.0289*
50% ordinary cement
50% ordinary cement
11.10.4 White cement without any
any pigment sqm
sqm 0.1205+0.0578*
0.1205+0.0578*
11.10.5 Light shade pigment with ordinary cement sqm
sqm 0.1783
11.10.6 Ordinary cement without any
any pigment sqm
sqm 0.1783
11.11
11.11 40 mm
40 thick marble
mm thick marble chips flooring with
chips flooring with under
under layer 28 mm
layer 28 thick
mm thick
cement concrete 1:2:4.
11.11.1
11.11.1 Dark shade pigment with ordinary cement sqm
sqm 0.1907
11.11.2 Light shade pigment with white cement sqm
sqm 0.1097+0.081*
0.1097+0.081*
11.11.3 Medium shade pigment
Medium shade with 50%
pigment with white cement
50% white cement and
and sqm
sqm 0.1502+0.0405*
0.1502+0.0405*
50% ordinary cement
50% ordinary cement
11.11.4 White cement without any
any pigment sqm 0.1097+0.081*
0.1097+0.081*
11.11.5 Light shade pigment with ordinary cement sqm 0.1097
11.11.6 Ordinary cement without any
any pigment sqm 0.1097

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 11.0 FLOORING 401
Code Description Unit Quantity of
No.
No. per
cement per
unit quantity of
work (Quintals)
11.12 Marble chips skirting:
skirting :
11.12.1
11.12.1 18 mm
18 mm thick with under layer 1212 mm
mm thick in cement
plaster
plaster 1:3
1:3 (1 cement : 3 coarse
(1 cement:3 coarse sand)
sand)
11.12.1.1
11.12.1.1 Dark shade pigment with ordinary cement sqm
sqm 0.1292
11.12.1.2 Light shade pigment with white cement sqm
sqm 0.0887+0.0405*
0.0887+0.0405*
11.12.1.3 Medium shade pigment
Medium shade with 50%
pigment with white cement
50% white and
cement and sqm
sqm 0.109+0.0203*
0.109+0.0203*
50% ordinary
50% ordinary cement
cement
11.12.1.4 White cement without any
any pigment sqm
sqm 0.109+0.0405*
0.109+0.0405*
11.12.1.5 Light shade pigment with ordinary cement sqm
sqm 0.1292
11.12.1.6 Ordinary cement without any
any pigment sqm
sqm 0.1292
11.15 Crazy
Crazy marble stone flooring
marble stone flooring
11.15.1
11.15.1 18 mm
18 mm thick crazy marble stone white, black or as
as sqm
sqm 0.1200+0.0405*
0.1200+0.0405*
specified
specified
** White Cement
TILE FLOORING
11.16 Precast terrazo tiles
Precast terrazo tiles 22mm
22mm thick
thick in floors, and
in floors, and landings on 20mm
landings on 20mm
thick bed
thick of cement
bed of cement mortar
mortar (1:4).
(1 :4).
11.16.1
11.16.1 Light shade using white cement sqm
sqm 0.0895+0.044*
0.0895+0.044*
11.16.2 Medium
Medium shade
shade using
using 50%white
50%white cement and 50%
cement and 50% sqm
sqm 0.0917+0.0220*
0.0917+0.0220*
ordinary cement
11.16.3 Dark shade using ordinary cement sqm
sqm 0.0939
11.16.4 Ordinary cement without any
any pigment sqm
sqm 0.0939
11.18 Precast terrazo tiles 22 mm thick in skirting and
22 mm and risers of steps.
11.18.1
11.18.1 Light shade using white cement. sqm
sqm 0.0734+0.066*
0.0734+0.066*
11.18.2 Medium
Medium shades
shades using
using 50% white cement
50% white cement and 50%
and 50% sqm
sqm 0.1064+0.033*
0.1064+0.033*
ordinary cement.
11.18.3 Dark shade using ordinary cement sqm
sqm 0.1394
11.18.4 Ordinary cement without any
any pigment sqm
sqm 0.1394
11.19 Chequered terrazo tiles
Chequered terrazo tiles 22
22 mm thick in
mm thick floors on
in floors 20 mm
on 20 thick bed
mm thick bed
of
of cement
cement mortar
mortar (1:4).
(1:4).
11.19.1
11.19.1 Light shade using white cement sqm
sqm 0.0895+0.044*
0.0895+0.044*
11.19.2 Medium shade using
Medium shade using 50% white cement,
50% white cement, 50%
50% sqm
sqm 0.0917+0.024*
0.0917+0.024*
ordinary cement
11.19.3 Dark shade using ordinary cement sqm
sqm 0.0939
11.19.4 Ordinary cement without any
any pigment sqm
sqm 0.0939
11.20 Chequerred precast cement concrete tiles 22 mm thick in foot path
22 mm
on
on 20
20 mm thick bed
mm thick of cement
bed of cement mortar
mortar (1:4).
(1:4).
11.20.1
11.20.1 Light shade using white cement sqm
sqm 0.1291+0.066*
0.1291+0.066*
11.20.2 Medium
Medium shade
shade using
using 50% white cement
50% white cement 50%
50% Grey
Grey sqm
sqm 0.1621+0.033*
0.1621+0.033*
cement
11.20.3 Dark shade using ordinary cement sqm
sqm 0.1951
0.1951
11.20.4 Ordinary cement without any
any pigment sqm
sqm 0.1951
0.1951

402
402 COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
FOR CEMENT S.H.:: 11.0 FL•OORING
FLOORING
Code Description Unit Quantity of
No.
No. per
cement per
unit quantity of
work (Quintals)
11.21
11.21 Providing
Providing and fixing 10mm
and fixing thick acid
10mm thick acid and
and or
or alkali
alkali resistant tiles.
resistant tiles.
11.21.1
11.21.1 In flooring on
In flooring onaa bed of 10
bed of 10 mm thick mortar
mm thick mortar 1:4
1:4 (1
(1 acid
acid
proof cement : 4 coarse
proof cement:4 coarse sand)
sand)
11.21.1.1
11.21.1.1 Acid and
and alkali resistant tile sqm
sqm 0.0786**
11.21.2 dado/skirting on
In dado/skirting on 12
12 mm
mm thick mortar 1:41:4 (1
(1 acid
proof cement : 4 coarse
proof cement:4 coarse sand)
sand)
11.21.2.1 Acid and
11.21.2.1 and alkali resistant tile sqm
sqm 0.0862“*
0.0862**
11.22 Tile work in skirting, risers of steps etc. with8 mm thick marble tile.
with 8 mm sqm
sqm 0.1044
STONE FLOORING
11.23 Marble
Marble stone flooring with
stone flooring with 18
18 mm thick marble
mm thick stone over
marble stone over 20
20 mm
mm sqm
sqm 0.13512
thick cement
thick cement mortar
mortar (1:4).
(1:4).
KOTA STONE FLOORING
11.26 Kota stone slab
Kota stone slab flooring
flooring over 20 mm
over 20 thick bed
mm thick bed of cement mortar
of cement mortar sqm
sqm 0.1491
0.1491
(1:4).
(1:4).
11.27 Kota stone slabs 20 mm thick in risers of steps, skirting etc. laid on
20 mm on sqm
sqm 0.1374
12
12 mm
mm (average) thick cement
(average) thick cement mortar
mortar 1:3.
1:3.
SAND STONE FLOORING
11.28 40 mm
40 thick fine
mm thick fine dressed
dressed stone
stone flooring
flooring over
over 2020 mm
mm (average)
(average) sqm
sqm 0.0775
thick base
thick of cement mortar
base ofcement mortar 1:5 with joints
1:5 with joints finished
finished flush.
flush.
11.29 40 mm
40 thick fine
mm thick fine dressed
dressed stone
stone flooring
flooring over
over 2020 mm
mm (average)
(average) sqm
sqm 0.0931
0.0931
thick base of
of cement mortar 1:5
1:5 including pointing with cement
mortar 1:2.
11.30 40 mm
40 thick rubbed
mm thick rubbed stone flooring over
stone flooring over 20
20 mm
mm (average) thick
(average) thick sqm
sqm 0.0931
0.0931
base ofcement 1:5with
of cement mortar 1:5 with joints 3mm
3mm thick, side buttered with
mortar11:2.
cement mortar :2.
CERAMIC GLAZED TILES
11.37 P/L ceramic glazed
P/L ceramic glazed floor
floor tiles
tiles laid on 20
laid on 20 mm thick Cement
mm thick Cement Mortar
Mortar sqm
sqm 0.1242
(1:4) with grey
(1:4) with grey cement
cement@@ 3.3kg/sqm
3.3kg/sqm
11.38 P/L
P/L ceramic
ceramic glazed floor tiles
glazed floor tiles laid
laid on 20mm thick
on 20mm thick bed
bed of
of Cement
Cement sqm
sqm 0.1242
Mortar
Mortar (1:4) with grey
(1:4) with grey cement
cement@@ 3.3kg/sqm
3.3kg/sqm
11.39&&
11.39 P/L
P/L rectified
rectified Glazed
Glazed Ceramic floor tiles
Ceramic floor tiles laid
laid on 20mm thick
on 20mm thick cement
cement sqm
sqm 0.1242
11.40 mortar
mortar (1:4).
(1:4).
VITRIFIED FLOOR TILES
11.41&&
11.41 P/L vitrified floor
P/Lvitrified floor tile
tile laid on 20mm
laid on 20mm thick
thick cement
cement mortar
mortar (1:4).
(1 :4). sqm
sqm 0.1242
11.41A
11.44 Crazy
Crazy ceramic tile flooring.
ceramic tile flooring. sqm
sqm 0.0646
11.46 P/L vitrified tile
P/L vitrified tile in skirting in
in skirting cement mortar
in cement mortar (1:3).
(1 :3). sqm
sqm 0.088
11.51
11.51 P/L
P/L Machine cut, Mirror
Machine cut, Mirror polished,
polished, Italian
Italian Marble stone flooring
Marble stone flooring Sqm. 0.085
0.085 +
+ 0.05*
0.05*
11.52 P/L
P/L Machine cut Mirror polished
Machine cutMirror polished Marble stone flooring
Marble stone flooring Sqm. 0.085
0.085 +
+ 0.05*
0.05*
11.55 P/L flamed finish
P/L flamed finish granite
granite stone
stone flooring
flooring 100 sqm.
100 13.50
11.56 P/L polished granite stone .........
......... 100 sqm.
100 13.50

* * White cement
** Acid alkali resistant cement.

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 11.0 FLOORING 403
403
1.0COEFFICIENTS FOR
1.0 FOR CEMENT CONSUMPTION
12.0 ROOFING

Code Description Unit Quantity of cement per


per
No.
No. unit quantity of work
(Quintals)

12.16 10 cm thick
10 cm thick mud
mud phaska with flat
phaska with flat tile
tile bricks grouted with
bricks grouted with
cement
cement mortar
mortar (1:3).
(1:3). 100 sqm
100 sqm 3.11
3.11
12.17 mud phaska with machine moulded tile bricks
10cm thick mud
grouted with
grouted with cement
cement mortar
mortar (1:3).
(1 :3). 100 sqm
100 sqm 3.11
3.11
12.19 and laying brick tiles over mumty roofs grouted
Providing and
with cement
with cement mortar
mortar (1:3).
(1:3). 100 sqm
100 sqm 9.13
12.20 Providing and
and laying pressed clay tiles on
on roofs jointed
with cement
with cement mortar
mortar (1:4).
(1:4). 100 sqm
100 sqm 9.92
12.21
12.21 Providing gola 75x75
Providing gola 75x75 mm
mm in
in cement
cement concrete
concrete (1:2:4).
(1 :2:4).
metre 0.031
0.031
12.22 Making khurras 45x45 cm cm with average minimum
thickness of5
thickness of 5 cm cement concrete
cm cement concrete (1:2:4).
(1:2:4). each 0.06
12.23 Providing sand stone
Providing sand stone slab for roofing
slab for and laying
roofing and laying cement
cement
mortar
mortar (1
(1:: 4).
4). sqm
100 sqm 0.74
12.38 Providing and fixing
Providing and fixing M.S.
M.S. holder
holder bat
bat clamps
clamps in
in cement
cement
concrete blocks 10x10x10cm ofof11:2:4
:2:4 mix. each 0.005
12.55 P/F
P/F heat
heat resistant tile on
resistant tile on roof with cement
roof with cement mortar
mortar (1:4)
(1:4)
and filling
and filling joints
joints with
with white
white cement
cement marble
marble mix.
mix. sqm
sqm 0.1291+0.044*
0.1291+0.044*

** White cement

404
404 FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 12.0 ROOFING
1.0COEFFICIENTS FOR
1.0 FOR CEMENT CONSUMPTION
13.0 FINISHING

Code Description Unit Quantity of cement


No.
No. perunit
per unit quantity of
work (Quintals)

(INFINE SAND)
CEMENT PLASTER (IN
13.1
13.1 12 mm
12 mm cement plaster:
plaster:
13.1.1
13.1.1 1:4
1:4 (1 cement : 4 fine
(1 cement:4 fine sand)
sand) 100 sqm
100 sqm 5.47
13.1.2 1:6
1:6 (1 cement : 6 fine
(1 cement:6 fine sand)
sand) 100 sqm
100 sqm 3.60
13.2 15 mm
15 mm cement plaster:
plaster:
13.2.1
13.2.1 1:4
1:4 (1 cement : 4 fine
(1 cement:4 fine sand)
sand) 100 sqm
100 sqm 6.54
13.2.2 1:6
1:6 (1 cement : 6 fine
(1 cement:6 fine sand)
sand) 100 sqm
100 sqm 4.30
13.3 20 mm cement plaster
20 mm plaster::
13.3.1
13.3.1 1:4
1:4 (1 cement : 4 fine
(1 cement:4 fine sand)
sand) 100 sqm
100 sqm 8.51
8.51
13.3.2 1:6
1:6 (1 cement : 6 fine
(1 cement:6 fine sand)
sand) 100 sqm
100 sqm 5.60
CEMENT PLASTER (IN
(INCOARSE SAND)
13.4 12 mm
12 mm cement plaster
plaster::
13.4.1
13.4.1 1:4
1:4 (1 cement : 4 coarse
(1 cement:4 coarse sand)
sand) 100 sqm
100 sqm 5.47
13.4.2 1:6
1:6 (1 cement : 6 coarse
(1 cement:6 coarse sand)
sand) 100 sqm
100 sqm 3.60
13.5 15 mm
15 mm cement plaster
plaster::
13.5.1
13.5.1 1:4
1:4 (1
(1 cement : 4 coarse
cement:4 coarse sand)
sand) 100 sqm
100 sqm 6.54
13.5.2 1:6
1:6 (1
(1 cement : 6 coarse
cement:6 coarse sand)
sand) 100 sqm
100 sqm 4.30
13.6 20 mm cement plaster
20 mm plaster::
13.6.1
13.6.1 1:4
1:4 (1
(1 cement : 4 coarse
cement:4 coarse sand)
sand) 100 sqm
100 sqm 8.51
8.51
13.6.2 1:6
1:6 (1
(1 cement : 6 coarse
cement:6 coarse sand)
sand) 100 sqm
100 sqm 5.60
CEMENT PLASTER WITHA
WITH A FLOATING COAT OF NEAT
CEMENT
13.7 12
12 mm
mm cement
cement plaster finished witha
plaster finished with a floating
floating coat
coat of
of neat
neat
cement:
cement :
13.7.1
13.7.1 1:3
1:3 (1
(1 cement : 3 fine
cement:3 fine sand)
sand) 100 sqm
100 sqm 9.54
13.7.2 1:4
1:4 (1
(1 cement : 4 fine
cement:4 fine sand)
sand) 100 sqm
100 sqm 7.67
13.8 15
15 mm
mm cement
cement plaster finished witha
plaster finished with a floating
floating coat
coat of
of neat
neat
cement::
cement
13.8.1
13.8.1 1:3
1:3 (1
(1 cement : 3 fine
cement:3 fine sand)
sand) 100 sqm
100 sqm 10.97
13.8.2 1:4
1:4 (1
(1 cement : 4 fine
cement:4 fine sand)
sand) 100 sqm
100 sqm 8.74
13.9 Cement
Cement plaster
plaster (1:3) finished witha
(1 :3) finished with a floating
floating coat of neat
coat of neat
cement.
13.9.1
13.9.1 12 mm
12 mm Cement Plaster 100 sqm
100 sqm 9.54
13.9.2 20 mm Cement Plaster
20 mm 100 sqm
100 sqm 13.62
13.10 15
15 mm
mm cement
cement plaster
plaster (1:3) finished witha
(1:3) finished with a floating
floating coat of
coat of
neat cement. 100 sqm
100 sqm 10.97

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 13.0 FINISHING 405
405
Code Description Unit Quantity of cement
No.
No. perunit
per unit quantity of
work (Quintals)
INTWO
CEMENT PLASTER IN TWO COATS
13.11
13.11 18 mm
18 mm cement plaster in two two coats under layer 12 12 mm
mm
thick cement
thick cement plaster
plaster 1:5 finished witha
1:5 finished with a top
top layer 6mm thick
layer 6mm thick
cement plaster 1:6. 100 sqm
100 sqm 6.26
13.12 mm cement plaster in two
18 mm 12 mm
two coats under layer 12 mm thick
plaster11:5
cement plaster :5 and
and aa top
top layer 6mm
6mm thick cement plaster
(1:3).
(1:3). 100 sqm
100 sqm 8.13
13.13 12
12 mm
mm cement
cement plaster
plaster 1:2
1:2 (1
(1 cement : 2 stone
cement:2 stone dust).
dust). 100 sqm
100 sqm 9.79
13.14 15
15 mm
mm cement
cement plaster
plaster 1:2
1:2 (1
(1 cement : 2 stone
cement:2 stone dust).
dust). 100 sqm
100 sqm 11.70
13.15 20
20 mm
mm cement
cement plaster
plaster 1:2
1:2 (1
(1 cement : 2 stone
cement:2 stone dust).
dust). 100 sqm
100 sqm 15.23
66 MM
MM CEMENT PLASTER
13.16 66 mm
mm cement plaster of mix
mix ::
13.16.1
13.16.1 1:3
1:3 (1 cement : 3 fine
(1 cement:3 fine sand)
sand) 100 sqm
100 sqm 3.67
13.17 66 mm
mm cement
cement plaster
plaster (1:3) finished witha
(1:3) finished with a floating
floating coat of
coat of
neat cement. 100 sqm
100 sqm 5.87
13.18 Neat cement punning 100 sqm
100 sqm 2.20
ROUGH CAST PLASTER
13.19 Rough cast plaster in two 12 mm
two layers, under layer 12 mm cement
plaster
plaster (1:4) and top
(1:4) and top layer
layer 10mm
10mm cement
cement plaster
plaster (1:3).
(1:3). 100 sqm
100 sqm 11.59
PEBBLE DASH PLASTER
13.20 Pebble dash plaster in two
two layers, under layer 12mm cement
plaster 1:4 and
and top
top layer 10mm cement plaster with cement
mortar
mortar (1:3).
(1 :3). 100 sqm
100 sqm 11.59
PLAIN CEMENT MORTAR BANDS
13.28 mm thick plain cement mortar bands in cement mortar
12 mm 100 metre
100
(1:4)
(1:4):: (Flush /Sunk / Raised
(Flush /Sunk/ Raised// Moulded
Moulded Band).
Band). 1cm wide
1cm 0.053
13.29 mm thick plain cement mortar band in cement mortar
18 mm 100 metre
(1:4)
(1:4) 1cm wide
1cm 0.076
13.30 mm thick moulded cement mortar band in two
18 mm two coats
under layer 12mm thick with cement mortar 1:5, top
top layer 100 metre
6mm thick with
6mm thick with cement
cement mortar
mortar (1:4).
(1:4). 1cm wide
1cm 0.07
OF BRICK WORK
POINTING OF
13.31
13.31 Pointing
Pointing on
on brick work with
brick work with cement
cement mortar
mortar (1:3)
(1 :3)::
13.31.1
13.31.1 Flush// Ruled/ Struck or weathered pointing
Flush 100 sqm
sqm 1.53
13.31.2 Raised and
and cut
cut pointing 100 sqm
sqm 2.04
ON TILE BRICK WORK
POINTING ON WORK
13.32 Pointing on tile
Pointing on tile brick work with
brick work with cement
cement mortar
mortar (1:3).
(1:3).
13.32.1
13.32.1 Flush/ Ruled/ Struck or weathered pointing 100 sqm
sqm 2.35
ON STONE WORK
POINTING ON
13.33 Pointing on stone
Pointing on stone work
work with
with cement
cement mortar
mortar (1:3).
(1:3).
13.33.1
13.33.1 Flush/ Ruled pointing 100 sqm
sqm 1.17
13.33.2 Raised and
and cut
cut pointing 100 sqm
sqm 2.35

406
406 FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 13.0 FINISHING
Code Description Unit Quantity of cement
No.
No. perunit
per unit quantity of
work (Quintals)
13.34 and cut
Raised and cut pointing on
on stone work in white cement
mortar
mortar (1:3).
(1 :3). 100 sqm
100 sqm 2.35*
13.35 Pointing
Pointing on
on stone
stone slab
slab ceiling with cement
ceiling with cement mortar
mortar (1:2).
(1:2). 100 sqm
100 sqm 1.02
13.72 Washed stone grit plaster on
on exterior walls in two
two layers
under
under layer
layer 12mm
12mm cement
cement plaster
plaster (1:4), top layer
(1 :4), top layer 15mm
15mm
plaster11:1/2:2.
cement plaster :1/2:2. 100 sqm
100 sqm 17.472
Note: - cement consumption forpointing
for pointing is same for
for modular
&& non modular bricks.

** White cement

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 13.0 FINISHING 407
1.0COEFFICIENTS FOR
1.0 FOR CEMENT CONSUMPTION
14.0 REPAIRS TO
TO BUILDING

Code Description Unit Quantity of cement


No.
No. perunit
per unit quantity of
work (Quintals)
14.1
14.1 Repairs to
to plaster of thickness 12
12 mm
mm to 20 mm in patches
20 mm 6.95
with cement mortar 1:4. 100 sqm
100 sqm
14.2 Fixing chowkhats in existing opening with hold fasts in
cement concrete blocks with cement concrete
concrete11:3:6.
:3:6.
14.2.1
14.2.1 Door chowkhats each 0.12
14.2.2 Window chowkhats each 0.06
14.2.3 Clerestory window chowkhats each 0.03
14.12 Providing
Providing and fixing 16
and fixing 16 mm
mm M.S.
M.S. Fan
Fan clamps
clamps in
in existing
existing 0.016
R.C.C. slab. each
14.13 Regrading terracing of mud
mud phaska to
to proper slope. 100 sqm
100 sqm 3.11
3.11
14.14 Replacing
Replacing sand
sand stone slabs in
stone slabs in roofing
roofing in
in cement
cement mortar
mortar 1:4.
1:4. 100 sqm
100 sqm 0.78
14.15 Renewing wooden battens in roofs
roofs&& making good theholes
the holes 0.36
in walls. cum
cum
14.16 Renewing wooden beams in roofs
roofs&& making good theholes
the holes 0.13
in walls. cum
cum
14.18 Flush
Flush pointing with cement
pointing with cement mortar
mortar11:3 for flat tile
:3 forflat tile bricks on
bricks on 0.76
top
top of mud
mud phaska. 100 sqm
100 sqm

408
408 COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
FOR CEMENT S.H.:: 14.0 REPAIRS TO BUILDING
1.0COEFFICIENTS
1.0 FOR CEMENT CONSUMPTION
COEFFICIENTS FOR
16.0 ROAD WORK

Code Description Unit Quantity of cement


No.
No. perunit
per unit quantity of
work (Quintals)
FENCING
16.23 P/F
P/F boundary
boundary stone
stone including finishing smooth
including finishing smooth with
with cement
cement
mortar
mortar (1:3).
(1 :3). each 0.082
16.24 P/F
P/F precast
precast R.C.C.
R.C.C. kilometre
kilometre stone
stone including finishing
including finishing
smooth in
smooth in cement
cement mortar
mortar (1:3).
(1:3).
16.24.1
16.24.1 35x111x25 cm
cm size each 0.37
16.24.2 50x152.5x25 cm cm size each 0.698
16.24.3 35x93.5x18 cmcm size each 0.23
CONCRETE PAVEMENT
16.42 Cement
Cement concrete
concrete (1:2:4)
(1 :2:4) in
in pavements.
pavements. cum
CUM 3.20
16.43 Providing and
and laying design mix cement concrete ofof M-30
grade, in roads/ taxi tracks/ runways, using cement content
as
as per design mix. cum
CUITI 3.40
16.46.1
16.46.1 Using
Using grade
grade “A” sealing compound
“A" sealing compound conforming
conforming
to
to IS:1834
MISCELLANEOUS
16.49 Making bell mouth opening including providing cement
concrete (1:3:6)
concrete (1:3:6)&& plastering with cement
plastering with cement mortar
mortar (1:3).
(1:3). 10 Nos. 6.60
16.52 Providing and fixing
Providing and fixing precast
precast lime fly ash
lime fly concrete blocks
ash concrete blocks
including finishing with
including finishing with 10mm thick cement
10mm thick cement mortar
mortar (1:3),
(1:3), in
in
foot paths. sqm
sqm 0.05
16.63 16.63 P/L kerb channel 30cm wide and and 50mm thick of
cement concrete
cement concrete (1:3:6).
(1:3:6). metre 0.11
0.11
16.67 Providing and fixing
Providing and fixing factory
factory made
made RCCRCC pavement slab of
pavement slab of
M-30 grade in footpath overa bed of
over a bed of 20mm average thick
cement mortar
cement mortar (1:5).
(1:5). 100 sqm
sqm 7.75
16.69 and laying factory made kerb stone of
Providing and of M-25 grade
jointed with
jointed with cement
cement mortar
mortar (1:3).
(1:3). cum
CUM 0.05
16.75 and laying C.C. pavement ofmix
Providing and of mix M-25 with ready
mixed concrete. cum
cum 3.30
16.80 Dry lean cement concrete sub
sub base. CUM
cum 1.50
16.85 Laying
Laying old
old kerb
kerb stones, jointed with
stones, jointed with cement
cement mortar
mortar (1:3).
(1:3). 100 metre 0.3723
16.86 P/L gang saw cut18
saw cut mm thick, morror polished
18 mm sqm
sqm 0.09
16.87 P/L gang saw cut30
saw cut mm thick mirror polished
30 mm sqm
sqm 0.09
16.88 P/L
P/L Matt finished vitrified
Matt finished vitrified tile
tile of
of size
size sqm
sqm 0.12
16.89 P/L
P/L Matt finished vitrifid
Matt finished vitrifid tile
tile of
of size
size sqm
sqm 0.12
16.90 P/L tactile tile sqm
sqm 0.12
16.92 P/F 10x10x7.5 cm.
cm. granite stone block sqm
sqm 1.85
16.93 Providing and
and Placing in position 100mm thick precast RCC
RCC
covers on
on drain of footpath sqm
sqm 0.352

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 16.0
Y6.0 ROAD WORK
WORK 409
409
1.0COEFFICIENTS
1.0 FOR CEMENT CONSUMPTION
COEFFICIENTS FOR
17.0 SANITARY INSTALLATIONS

Code Description Unit Quantity of cement


No.
No. perunit
per unit quantity of
work (Quintals)
17.1/17.2/17.3 Fixing Indian European type W.C. pan. each 0.05
17.4 Fixing white vitreous china urinal basin
basin::
17.4.1
17.4.1 One urinal
One urinal basin with 5 litre
basin with5 white P.V.C.
litre white P.V.C.
automatic flushing
automatic flushing cistern
cistern each 0.025
17.4.2 Range oftwo
of two urinal basins with5
with 5 litre white
P.V.C.
P.V.C. automatic flushing cistern
automatic flushing cistern each 0.04
17.4.3 Range ofof three urinal basins with 10litre
10Iitre
white P.V.C.
white automatic flushing
P.V.C. automatic flushing cistern
cistern each 0.067
17.4.4 Range ofof four urinal basins with 1010 litre
white P.V.C.
white automatic flushing
P.V.C. automatic flushing cistern
cistern each 0.095
17.5 Fixing white vitreous
Fixing white vitreous china flat back
china flat back half stall urinal
half stall urinal::
17.5.1
17.5.1 Single half
Single stall urinal
half stall with 55 litre
urinal with litre P.V.C.
P.V.C.
automatic flushing
automatic flushing cistern
cistern each 0.051
0.051
17.5.2 Range oftwo
of two half stall urinals with5
with 5 litre
P.V.C.
P.V.C. automatic flushing cistern
automatic flushing cistern each 0.102
17.5.3 Range ofofthree
three half stall urinals with 10
10 litre
P.V.C.
P.V.C. automatic flushing cistern
automatic flushing cistern each 0.153
17.5.4 Range offour
of four half stall urinals with 10
10 litre
P.V.C.
P.V.C. automatic flushing cistern
automatic flushing cistern each 0.203
17.6 Fixing one
one piece construction white vitreous china
plate::
squatting plate
17.6.1
17.6.1 Single squatting
Single squatting plate with 55 litre
plate with litre P.V.C.
P.V.C.
automatic flushing
automatic flushing cistern
cistern each 0.051
0.051
17.6.2 Range oftwo
of two squatting plates with5 with 5 litre
P.V.C.
P.V.C. automatic flushing cistern
automatic flushing cistern each 0.102
17.6.3 Range ofthree
of three squatting plates with 10 10 litre
P.V.C.
P.V.C. automatic flushing cistern
automatic flushing cistern each 0.153
17.6.4 Range offour
of four squatting plates with 10 10 litre
P.V.C.
P.V.C. automatic flushing cistern
automatic flushing cistern each 0.203
17.7 Fixing wash basin with C.I. brackets. each 0.025
17.8 Fixing white vitreous china pedestal forwash
for wash basin. each 0.016“
0.016*
17.9 Fixing kitchen sink with C.I. brackets. each 0.025
17.10 Fixing kitchen sink with C.I. brackets. each 0.025
17.11
17.11 Fixing kitchen sink with C.I. brackets. each 0.025
17.12 Fixing draining board with C.I. brackets. each 0.014
17.13 Fixing White vitreous china water closet squatting pan. each 0.025
17.17 Fixingaa pair of white vitreous china foot rests.
Fixing each 0.025
17.23 Fixing white vitreous
Fixing white vitreous china flat urinal
china flat urinal basin.
basin. each 0.01
0.01
17.24 Fixing white vitreous china squatting plate urinal. each 0.02
17.25 Fixing white vitreous china wash basin. each 0.015

410
410 COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
FOR CEMENT S.H.:: 17.0 SANITARY
SANITARY INSTALLATIONS
Code Description Unit Quantity of cement
No.
No. perunit
per unit quantity of
work (Quintals)

17.26 Fixing kitchen sink. each 0.015


17.27 Fixing kitchen sink. each 0.015
17.37 Providing
Providing and fixing M.S.
and fixing M.S. holder-bat
holder-bat clamps.
clamps. each 0.005
17.59 Providing
Providing and fixing M.S.
and fixing M.S. stays and clamps.
stays and clamps. each 0.005
17.60 Providing
Providing and fixing trap
and fixing trap of
of self-cleansing design.
self-cleansing design. each 0.025
17.61
17.61 Cutting chases in brick masonry walls forfor sand cast iron/
centrifugally
centrifugally cast
cast (spun)
(spun) iron
iron pipes and making
pipes and good the
making good the
same with C.C.(1:3:6).
same with C.C.(1:3:6).
17.61.1
17.61.1 100 mm
100 mm dia 100 metre 5.40
17.61.2 75 mm
75 mm dia
100 metre 3.70
17.61.3 50 mm
50 mm dia 100 metre 1.87

*”White
White Cement.

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 17.0 SANITARY
SANITARVINSTAL•L•ATIONS
INSTALLATIONS 411
411
1.0COEFFICIENTS
1.0 FOR CEMENT CONSUMPTION
COEFFICIENTS FOR
18.0 WATER SUPPLY

Code Description Unit Quantity of cement


No.
No. perunit
per unit quantity of
work (Quintals)
18.1/18.4/18.7 Providing and fixing
Providing and fixing G.I./
G.I./ PE-AL-PE/
PE-AL-PE/ PP-R /CPVC/
PP-R /CPVC/
/18.10/18.85/1 SS pipes.
/18.10/18.85/1 SS
8.85A
Internal work - Exposed on wall
18.10.1
18.10.1 15 mm
15 mm dia nominal bore 100 metre
100 0.05
18.10.2 20 mm dia nominal bore
20 mm 100 metre 0.06
18.10.3 25 mm dia nominal bore
25 mm 100 metre 0.07
18.10.4 32 mm
32 mm dia nominal bore 100 metre 0.075
18.10.5 40 mm dia nominal bore
40 mm 100 metre 0.08
18.10.6 50 mm
50 mm dia nominal bore 100 metre 0.08
18.2/18.5/18.8 P/F concealed pipes.
/18.11/18.86/1
/18.11/18.86/1
8.86A 100 metre 0.88
18.32 Constructing masonry Chamber 0x30x50 cm, for
for
stop cock. each 0.26
18.33 Constructing masonry Chamber 60x60x75 cm, for
for
sluice valve. each 1.44
18.34 Constructing masonry Chamber 90x90x100 cm, for for
sluice valve. each 2.48
18.35 Constructing masonry Chamber 120x120x100 cm,
forsluice
for sluice valve. each 3.50
18.36 Constructing masonry Chamber 60x60x75 cm, for for
fire hydrants.
fire hydrants. each 1.30
18.37 Constructing masonry Chamber 60x45x50 cm, for for
water meter. each 1.34
18.76 Cutting holes up up to 30x30 cmcm in walls including
making good thesame.
the same. 100 Nos. 2.92
18.77 Cutting
Cutting holes
holes up to 15x15
up to 15x15 cm
cm in
in R.C.C. floors and
R.C.C. floors and
roofs and
and repairing the
the hole after insertion of drain
pipes etc. with
pipes etc. with cement
cement concrete
concrete (1:2:4).
(1:2:4). 100 Nos. 0.70
18.78 Making chases up to to 7.5x7.5 cm
cm in walls including
finishing.
finishing. 100 metre 0.88
18.79 up to 20x20 cm
Making hole up cm and embedding pipes
up to 150
up to 150 mm diameter in
mm diameter in masonry and filling
masonry and filling with
with
cement concrete (1:3:6).
cement concrete (1:3:6). 100 metre 4.90

412 FOR CEMENT


COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 18.0 WATER SUPPLY
SUPPLV
1.0COEFFICIENTS
1.0 FOR CEMENT CONSUMPTION
COEFFICIENTS FOR
19.0 DRAINAGE

Code Description Unit Quantity of cement


No.
No. perunit
per unit quantity of
work (Quintals)
19.1
19.1 Jointing glazed
Jointing glazed stoneware
stoneware pipes with stiff
pipes with stiff mixture of cement
mixture of cement
mortar
mortar in the proportion
in the of (1:1).
proportion of (1:1).
19.1.1
19.1.1 100 mm
100 mm diameter 100 metre
100 2.17
19.1.2 150 mm
150 mm diameter 100 metre 3.23
19.1.3 200 mm diameter
200 mm 100 metre 4.33
19.1.5 250 mm diameter
250 mm 100 metre 5.40
19.1.6 300 mm
300 mm diameter 100 metre 6.47
19.2 Laying cement concrete
Laying cement concrete (1:5:10) alround S.W.
(1 :5:10) alround S.W. pipes:
pipes:
19.2.1
19.2.1 100 mm
100 mm diameter S.W. pipe 100 metre 19.24
19.2.2 150 mm
150 mm diameter S.W. pipe 100 metre 23.53
19.2.3 200 mm diameter S.W. pipe
200 mm 100 metre 27.43
19.2.5 250 mm diameter S.W. pipe
250 mm 100 metre 31.72
19.3 Laying cement concrete
Laying cement concrete (1:5:10)
(1:5:10) upto
upto haunches of S.W.
haunches of S.W.
pipes:
19.3.1
19.3.1 100 mm
100 mm diameter S.W. pipe 100 metre 9.14
19.3.2 150 mm
150 mm diameter S.W. pipe 100 metre
100 14.82
19.3.3 200 mm diameter S.W. pipe
200 mm 100 metre
100 17.42
19.3.4 250 mm
250 mm diameter S.W. pipe 100 metre
100 20.28
19.3.5 300 mm
300 mm diameter S.W. pipe 100 metre
100 23.40
19.4 Providing
Providing and fixing square-mouth
and fixing square-mouth S.W. gully trap:
S.W. gully trap :
19.4.1
19.4.1 mm size
100x100 mm sizePP type each 0.27
19.4.2 150xx 100
150 100 mm
mm size
sizePP type. each 0.26
19.4.3 mm size
180x150 mm sizePP type each 0.25
19.6 P/L
P/L NP2 class R.C.C.
NP2 class R.C.C. pipes with collars
pipes with collars jointed
jointed with
with stiff
stiff
mixture
mixture of
of cement
cement mortar
mortar in the proportion
in the proportion of
of (1:2):
(1:2):
19.6.1
19.6.1 100 mm
100 mm dia. R.C.C. pipe 100 metre
100 0.50
19.6.2 150 mm
150 mm dia. R.C.C. pipe 100 metre 0.60
19.6.3 250 mm dia. R.C.C. pipe
250 mm 100 metre 0.90
19.6.4 300 mm dia. R.C.C. pipe
300 mm 100 metre 1.10
19.6.5 450 mm dia. R.C.C. pipe
450 mm 100 metre 2.40
19.6.6 500 mm dia. R.C.C. pipe
500 mm 100 metre 2.60
19.6.7 600 mm dia. R.C.C. pipe
600 mm 100 metre 3.20
19.6.8 700 mm
700 mm dia. R.C.C. pipe 100 metre 3.70
19.6.9 800 mm dia. R.C.C. pipe
800 mm 100 metre 4.20
19.6.10 900 mm dia. R.C.C. pipe
900 mm 100 metre 4.90
19.6.11
19.6.11 mm dia. R.C.C. pipe
1000 mm 100 metre 5.50

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 19.0 DRAINAGE 413
413
Code Description Unit Quantity of cement
No.
No. perunit
per unit quantity of
work (Quintals)
19.6.12 mm dia. R.C.C. pipe
1100 mm 100 metre 6.10
19.6.13 mm dia. R.C.C. pipe
1200 mm 100 metre 6.80
19.7 Constructing
Constructing brick
brick masonry
masonry manhole
manhole in cement mortar
in cement mortar (1:4).
(1 :4).
19.7.1
19.7.1 Inside size 90x80 cm
cm and 45 cm
cm deep each 2.92
19.7.2&&
19.7.2 Inside size 120x90 cm
cm and 90 cm.deep
19.7.3 each 4.73
19.8 Extra fordepth
for depth formanholes
for manholes
19.8.1
19.8.1 Size 90x80 cm
cm metre 1.26
19.8.2 Size 120x90 cm
cm metre 1.52
19.9 Constructing brick masonry circular type manhole 0.91 m
0.91 m
internal dia
dia at bottom and
and 0.56m diaattopin
dia at top in cement mortar
(1:4).
(1 :4).
19.9.1
19.9.1 0.91 m
0.91 m deep each 2.75
19.10 Extra depth forcircular
for circular type manhole 0.91m internal dia
dia (at
bottom) with beyond
bottom) with beyond 0.91m to 1.67m
0.91m to 1.67m metre 1.40
19.11
19.11 Constructing brick masonry circular manhole 1.22 m
m internal
dia at
dia at bottom and 0.56m
bottom and dia at top in cement
0.56m diaattopin cement mortar
mortar (1:4).
(1:4).
19.11.1
19.11.1 m deep
1.68 m each 5.39
19.12 Extra depth forcircular
for circular type manhole 1.22m internal dia
dia (at
bottom)
bottom) beyond
beyond 1.68
1.68 m to 2.29
m to 2.29 m.
m. metre 1.43
19.13 Constructing brick masonry circular manhole 1.52 m
m internal
dia at
dia at bottom and 0.56
bottom and 0.56 m dia at
m dia at top
top in cement mortar
in cement mortar (1:4).
(1:4).
19.13.1
19.13.1 2.30 m
m deep each 10.86
19.14 Extra depth forcircular
for circular type manhole 1.52 m
m internal dia
dia (at
bottom)
bottom) beyond 2.30 m.
beyond 2.30 m. metre 3.11
3.11
19.15 Providing
Providing M.S. foot rests
M.S. foot rests including fixing in
including fixing in manholes with
manholes with
20x20x10 cm cement
20x20x10 cm cement concrete
concrete blocks
blocks (1:3:6).
(1:3:6). 100 nos.
100 0.88
19.16 Providing orange colour safety foot rest. 100 nos.
100 1.98
19.17 Replacement of
of M.S. foot rests in manholes with
20x10x10 cm
20x10x10 cm C.C.
C.C. blocks
blocks (1:3:6)
(1:3:6) mix.
mix. 100 nos.
100 0.88
19.19 Providing and fixing
Providing and fixing in
in position
position precast
precast R.C.C.
R.C.C. manhole
manhole
and frame.
cover and
19.19.1
19.19.1 LD- 2.5
LD-
19.19.1.1 Rectangular
19.19.1.1 shape 600x450mm internal
dimensions each 0.128
19.19.1.2 Square shape 450mm internal dimensions each 0.096
19.19.1.3 Circular shape 450mm internal diameter each 0.096
19.19.2 MMDD -- 10
10
19.19.2.1 Square shape 450mm internal dimension
19.19.2.1 each 0.128
19.19.2.2 Circular shape 500mm internal diameter each 0.096
19.19.3 HHDD - 20
20
19.19.3.1 Circular shape 560 mm
19.19.3.1 mm internal diameter each 0.096

414
414 FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 19.0 DRAINAGE
Code Description Unit Quantity of cement
No.
No. perunit
per unit quantity of
work (Quintals)
19.19.4 EHD - 35
EHD 35
19.19.4.1 Circular shape 560 mm
19.19.4.1 mm internal dia
dia each 0.096
19.21
19.21 Making connection of
of drain or sewer line with existing
manhole
manhole and
and making good thewalls,
making good the walls, floors
floors with
with C.C.(1:2:4)
C.C.(1 :2:4)
mix.
19.21.1
19.21.1 For pipes 100
For 100 to 250 mm diameter
250 mm each 0.056
19.21.2 100 to 300
For pipes 100 300 mm
mm diameter each 0.095
19.21.3 100 to 450
For pipes 100 mm diameter
450 mm each 0.153
19.22 Providing sand cast iron drop connection externally for 60
60
cm drop from branch sewer line to main sewer manhole.
cm manhole.::
19.22.1
19.22.1 100 mm
100 mm dia sand cast iron drop connection each 0.34
19.22.2 150 mm
150 mm dia sand cast iron drop connection
connection each 0.46
19.23 Extra for
for depths beyond 60 cm of sand cast iron drop
cm of
connection.::
connection.
19.23.1
19.23.1 For 100
For 100 mm
mm dia. sand cast iron drop connection metre 0.21
0.21
19.23.2 150 mm
For 150 mm dia. sand cast iron drop connection metre 0.26
19.27 Constructing brick masonry road gully chamber 50x45x
60cm
60cm in cement mortar
in cement mortar (1:4).
(1 :4). each 0.93
19.28 Constructing brick masonry road gully chamber 45x45x 77.5
cm
cm in cement mortar
in cement mortar (1:4).
(1 :4). each 0.82
19.29 Constructing brick masonry road gully chamber 110x50x
77.5
77.5 cm
cm in cement mortar
in cement mortar (1:4).
(1 :4). each 1.66
19.30 Constructing brick masonry chamber forunderground
for underground C.I.
inspection
inspection chamber
chamber and
and bends
bends in
in cement
cement mortar
mortar (1:4).
(1:4).
19.30.1
19.30.1 Inside dimensions 455x610 mm
mm and 45 cm
cm deep
for
for single pipe line each 0.90
19.30.2 Inside dimensions 500x700 mm mm and 45 cm
cm deep
forpipe
for pipe line with one
one or two
two inlets each 1.02
19.30.3 Inside dimensions 600x 850 mm mm and 45 cmcm
deep forpipe
for pipe line with three or more inlets each 1.27
19.31
19.31 Extra fordepth
for depth beyond 45 cm cm ofbrick
of brick masonry chamber:
chamber :
19.31.1
19.31.1 For 455x610 mm
For mm size metre 0.87
19.31.2 For 500x700 mm
mm size metre 0.95
19.31.3 For 600x850 mm
mm size metre 1.12
19.32 Making soak pit 2.5
2.5 m
m diameter 3.0 metre deep. each 0.072
19.34 Providing
Providing and fixing S.W.
and fixing S.W. intercepting trap in
intercepting trap in manholes with
manholes with
stiff mixture
stiff of cement
mixture of cement mortar
mortar (1:1).
(1 :1).
19.34.1
19.34.1 100 mm
100 mm dia each 0.013
19.34.2 150 mm
150 mm dia each 0.019
19.35 Non pressure Np-3 class
P/L Non
19.35.1
19.35.1 450 mm dia RCC
450 mm RCC pipe 100 metre 1.20
19.35.2 600 mm dia RCC
600 mm RCC pipe 100 metre 1.60

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 19.0 DRAINAGE 415
415
Code Description Unit Quantity of cement
No.
No. perunit
per unit quantity of
work (Quintals)
19.35.3 900 mm dia RCC
900 mm RCC pipe 100 metre
100 2.50
19.35.4 mm diaRCC
1000 mm dia RCC pipe 100 metre 2.80
19.35.5 mm diaRCC
1200 mm dia RCC pipe 100 metre
100 3.40
19.35.6 mm diaRCC
1800 mm dia RCC pipe 100 metre 4.90
19.36 Non pressure Np-4 class
P/L Non 100 metre
100
19.36.1
19.36.1 450 mm dia RCC
450 mm RCC pipe 100 metre 1.20
19.36.2 600 mm dia RCC
600 mm RCC pipe 100 metre
100 1.60
19.36.3 900 mm
900 mm dia RCC
RCC pipe 100 metre 2.50
19.36.4 mm diaRCC
1000 mm dia RCC pipe 100 metre
100 2.80
19.36.5 mm diaRCC
1200 mm dia RCC pipe 100 metre 3.40
19.36.6 mm diaRCC
1800 mm dia RCC pipe 100 metre 4.90

416
416 FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 19.0 DRAINAGE
DRAINAGE
1.0COEFFICIENTS
1.0 FOR CEMENT CONSUMPTION
COEFFICIENTS FOR
20.0 PILE WORK

Code Description Unit Quantity of cement per


per
No.
No. unit quantity of work
(Quintals)

20.1
20.1 Providing, driving and
Providing, installing driven cast-in-situ
and installing
reinforced cement concrete piles of gradeM
grade M -25.

20.1.1
20.1.1 400 mm dia piles
400 mm metre 0.414
20.1.2 450 mm dia piles
450 mm metre 0.525
20.1.3 500 mm
500 mm dia piles metre 0.648
20.1.4 550 mm
550 mm dia piles metre 0.784
20.1.5 750 mm
750 mm dia piles metre 1.456
20.1.6 1000 mm
mm diapiles
dia piles metre 2.590
20.1.7 mm diapiles
1200 mm dia piles metre 3.729
20.1.8 mm diapiles
1500 mm dia piles metre 5.83
20.2 and installing
Boring, providing and installing bored cast-in-situ
reinforced cement concrete piles of gradeM
grade M -25 by tripod
and
and mechanical winch machine.
20.2.1
20.2.1 450 mm dia piles
450 mm metre 0.525
20.2.2 500 mm
500 mm dia piles metre 0.648
20.2.3 600 mm
600 mm dia piles metre 0.932
20.2.4 750 mm
750 mm dia piles metre 1.456
20.2A Boring, providing and installing bored cast-in-situ
and installing cast-in-situ reinforced
cement concrete piles of gradeM
grade M -25 by crawler mounted,
telescopic boom hydraulic pilling Rig.
20.2A.1
20.2A.1 600 mm dia piles
600 mm metre 0.932
20.2A.2 750 mm
750 mm dia
dia piles metre 1.456
20.2A.3 mm diapiles
1000 mm dia piles metre 2.590
20.2A.4 mm diapiles
1200 mm dia piles metre 3.729
20.2A.5 1500 mm mm diapile
dia pile metre 5.830
20.3 and installing
Boring, Providing and installing cast in situ single under
reamed piles of gradeM
grade M -25.
20.3.1
20.3.1 300 mm
300 mm dia piles metre 0.257
20.3.2 400 mm dia piles
400 mm metre 0.488
20.3.3 450 mm dia piles
450 mm metre 0.629
20.3.4 550 mm dia piles
550 mm metre 0.792
20.4 Extra for
for providing additional bulb in under reamed piles.
20.4.1
20.4.1 300 mm
300 mm dia piles each 0.109
20.4.2 400 mm dia piles
400 mm each 0.208
20.4.3 450 mm dia piles
450 mm each 0.267
20.4.4 550 mm
550 mm dia piles each 0.337

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 20.0 PILE
PIL•E WORK
WORK 417
417
Code Description Unit per
Quantity of cement per
No.
No. unit quantity of work
(Quintals)

20.5 Providing, driving and


Providing, and installing driven Pre-cast reinforced
gradeMM -25.
cement concrete piles of grade
20.5.1
20.5.1 400 mm dia piles
400 mm metre 0.414*
20.5.2 450 mm dia piles
450 mm metre 0.525*
20.5.3 500 mm
500 mm dia piles metre 0.648*
20.5.4 550 mm
550 mm dia piles metre 0.784*
20.5.5 750 mm
750 mm dia piles metre 1.795*
20.5.6 mm dia
1000 mm diapiles
piles metre 2.590*

** at precast stage

418
418 FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 20.0 PILE
PILE WORK
WORK
1.0COEFFICIENTS
1.0 FOR CEMENT CONSUMPTION
COEFFICIENTS FOR
22.0 WATER PROOFING

Code Description Unit Quantity of cement


No.
No. perunit
per unit quantity of
work (Quintals)

22.1
22.1 P/L
P/L integral cement based
integral cement treatment for
based treatment for water
water proofing on
proofing on
horizontal surface.:
surface. :
22.1.1
22.1.1 Using
Using rough
rough kota
kota stone
stone sqm
sqm 0.335
22.2 P/L
P/L integral cement based
integral cement treatment forwater
based treatment for water proofing
proofing on the
on the
vertical surface.:
surface. :
22.2.1
22.2.1 Using
Using rough
rough Kota stone
Kota stone sqm
sqm 0.437
22.3 P/L water proofing
P/L water treatment to
proofing treatment to vertical
vertical and
and horizontal
horizontal
surfaces of depressed portions of W.C., kitchen and and the like
consisting of:
i)
i) Ist
Ist course of applying
course of cement slurry
applying cement slurry@@ 4.4
4.4 kg/sqm
kg/sqm
ii)
ii)IIInd
Ind course of 20mm
course of 20mm cement
cement plaster
plaster (1:3)
(1:3)
iii)
iii) IIIrd
IIIrd course of applying
course of applying blown or residual
blown or residual bitumen
bitumen applied
applied
hot at 1.7 Kg.
Kg. per sqm
sqm of area
iv)
iv) IVth course of400
IVth course of 400 micron thick PVC
micron thick sheet
PVC sheet sqm
sqm 0.158
22.5 P/L water proofing
P/L water treatment in
proofing treatment sunken portion
in sunken of WCs,
portion of WCs,
bathroom etc. sqm
sqm 0.0123
22.6 P/L water proofing
P/L water treatment on
proofing treatment on roofs.
roofs. sqm
sqm 0.0195
22.7 P/L
P/L integral
integral cement
cement based water proofing
based water treatment on
proofing treatment on roofs,
roofs,
balconies, terraces etc.:
etc. :
22.7.1
22.7.1 With average thickness of 120mm and and minimum
thickness at khurra as
as 65
65 mm
mm sqm
sqm 0.365
22.14 Grading
Grading roof for water
roof for water proofing treatment with
proofing treatment with
22.14.1
22.14.1 Cement concrete 1:2:4 cum
cum 3.20
22.14.2 1:3
Cement mortar 1:3 cum
cum 5.10
22.14.3 1:4
Cement mortar 1:4 CUM
cum 3.80

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 22.0 WATER
WATER PROOFING 419
419
1.0COEFFICIENTS FOR
1.0 FOR CEMENT CONSUMPTION
26.0 NEW
NEW TECHNOLOGIES AND
AND MATERIALS

Code Description Unit Quantity of cement


No.
No. perunit
per unit quantity of
work (Quintals)

26.31.1
26.31.1 SBR
SBR Polymer
Polymer (@10%
(@10% of of cement weight) modified
cement weight) modified
cementitious bond coat @2.2 kg
kg cement per
persqm.
sqm. 100 sqm
100 sqm 2.20
26.32 and applying SBR
Providing, mixing and SBR polymer (of (of
approved
approved make)
make) modified
modified Cement
Cement mortar
mortar in
in proportion
proportion
(1 cement:4
of 1:4 (1 cement: 4 graded coarse sand with polymer
minimum
minimum 2%2% by wt. of cement used)
by wt.ofcement used)..
26.32.1
26.32.1 12 mm
12 mm average thickness.
thickness. 100 sqm
100 sqm 5.47
26.32.2 25 mm
25 mm average thickness in
in2 2 layers. 100 sqm
100 sqm 11.40
26.32.3 50 mm
50 mm average thickness in
in3 3 layers. 100 sqm
100 sqm 22.80
26.33 Providing, mixing and
Providing, and applying SBRSBR polymer (of (of
approved
approved make
make@@ minimum
minimum 2%2% by wt. of cement used)
by wt.ofcement used)
modified
modified plain/reinforced
plain/reinforced cement
cement concrete for structural
concrete forstructural
members.
26.33.1
26.33.1 50mm thick in Grade MM 25 with cement
content not less than 330
330 kg per cum
cum 100 sqm
100 sqm 16.50
26.33.2 75mm thick in Grade MM 25 with cement
content not less than 330
330 kg per cum
cum 100 sqm
100 sqm 24.75
26.34 Providing and laying
Providing and laying SBR
SBR Polymer
Polymer modified
modified (of approved
(ofapproved
make
make@@ minimum
minimum 2% 2% by wt. of cement
by wt.of cement used)
used) plain/
plain/
reinforced concrete jacket forfor the structural
structural members
e.g. columns, pillars, piers, beams etc
etc with concrete.

26.34.1
26.34.1 50mm thick in Grade MM 25 with cement
content not less than 330
330 kg per cum
cum 100 sqm
100 sqm 16.50
26.34.2 75mm thick in Grade MM 25 with cement
content not less than 330
330 kg per cum
cum 100 sqm
100 sqm 24.75
26.34.3 100mm thick in Grade
GradeMM 25 with cement
content not less than 330
330 kg per cum
cum 100 sqm
100 sqm 33.00
26.35 and injecting approved grout in proportion
Providing and
recommended by by the
the manufacturer into cracks/honey-
comb area of
of concrete/masonry by suitable gun/pump.

26.35.1
26.35.1 Stirrer mixed Acrylic Polymer of
of approved
make
make @@ 2% 2% of
of weight
weight of
of cement
cement used)
used)
modified
modified Cement slurry made
Cement slurry with non
made with non
shrink compound in concrete/RCC work 100 kg
100 kg 1.00
26.35.2 SBR Polymer (of
Stirrer mixed SBR (of approved
make)
make) modified
modified Cement slurry made
Cement slurry made
with Shrinkage Compensating Cement in
concrete/RCC work. 100 kg
100 kg 1.00
26.38 Shotcreting R.C.C. columns, beams andand slabs etc. in
layers with approved design mix concrete having
having..
26.38.1
26.38.1 25mm thick in Grade MM 25 with cement
content not less than 330
330 kg per cum
cum 100 sqm
100 sqm 10.31
10.31

420
420 COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
FOR CEMENT S.H.:: 26.0 NEW
NEW TECHNOLOGIES
TECHNOI.OGIES AND
AND MATERIAL•S
MATERIALS
Code Description Unit Quantity of cement
No.
No. perunit
per unit quantity of
work (Quintals)

26.38.2 50mm thick in Grade MM 25 with cement


content not less than 330
330 kg per cum
cum 100 sqm
100 sqm 20.63
26.38.3 75mm thick in Grade MM 25 with cement
content not less than 330
330 kg per cum
cum 100 sqm
100 sqm 30.94
26.46 Providing and fixing
Providing and fixing inin position, 200 mm
position, 200 thick factory
mm thick factory
made
made Expanded olystyrene Core
Expanded olystyrene Core (EPS
(EPS Core) wall
Core) wall
panels consisting of EPS EPS core sandwiched between
two Engineered sheets of of welded wire fabric
mesh.....................applying the 50 mm
the layer of 50 mm thick
cement mortar
cement mortar 1:3 1:3 (1 cement: 3 coarse
(1 cement:3 coarse sand)
sand) 100 sqm
100 sqm 51.00
26.47 Providing
Providing and fixing in
and fixing in position, 230mm thick
position, 230mm thick factory
factory
made
made Expanded
Expanded Polystyrene
Polystyrene Core
Core (EPS
(EPS Core)
Core) roof/
roof/
floor panels...........
floor panels........... applying
applyingaa layer of 60-65
layer of 60-65 mm thick
mm thick
mortar1:
cement mortar 1:3 3 (1 cement:33 coarse sand............
{1 cement:
applying 70-75 mm mm thick layer of cement concrete 1:1.5:
3 3 (1
(1 cement :1.5 coarse sand:3
sand : 3 graded stone aggregate
20
20 mmmm nominal size).
nominal size). 100 sqm
100 sqm 58.60
26.53 Filling of
of empty cavities with quarry dust mixed with
cement cum
cum 0.72
26.58 Filling of joints
Filling of joints between
between RCC
RCC plinth
plinth beam/floor
beam/floor slab
slab and
and
wall panel ofof external walls 100 metre
100 0.03125
26.59 Waterproofing treatment
Waterproofing treatment of
of vertical
vertical joints
joints between
between door
door
frame, window&
window & ventilator frames 100 metre
100 0.03125
26.61
26.61 In filling/ sealing
In filling/ of joint
sealing of joint between
between RCC
RCC lintel cum
lintel cum
sunshade and wall 100 metre
100 0.03125
26.66 P/F factory made EPS wall panels consisting EPS
EPS core
sandwhiched between two Engineered sheets sqm
sqm 0.357
26.68 P/F Factory made Precast Concrete solid blocks in
foundation and
and plinth sqm
sqm 0.2825
26.69 P/F Factory made Precast Concrete solid blocks in
superstructure
superstructure above
above plinth
plinth level
level up to floorV
up to floor V level
level cum
CUM 0.2825
26.70 and laying half block masonry with factory
Providing and
made Precast concrete solid blocks in foundation and
and
plinth 100 sqm
100 sqm 2.6904
26.71
26.71 and laying half block masonry with factory
Providing and
made Precast concrete solid blocks in superstructure
above
above plinth
plinth level
level up to floorV
up to floor V level
level 100 sqm
100 sqm 2.6904
26.73.1
26.73.1 Fabrication&& Manufacturing of
Fabrication of prestressed Hollow Core
slab of concrete
slab of grade M-40
concrete grade M-40 (cement
(cement conetent 400kg)
conetent 400kg)
26.73.1.1
26.73.1.1 100 mm
100 mm thick hollow core slab metre 0.36
26.73.1.2 120 mm
120 mm thick hollow core slab metre 0.432
26.73.1.3 150 mm
150 mm thick hollow core slab metre 0.54
26.73.1.4 200 mm thick hollow core slab
200 mm metre 0.672
26.73.1.5 250 mm thick hollow core slab
250 mm metre 0.84

FOR CEMENT
COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
S.H.:: 26.0 NEW
NEW TECHNOLOGIES AND
AND MATERIAL•S
MATERIALS 421
421
Code Description Unit Quantity of cement
No.
No. perunit
per unit quantity of
work (Quintals)

26.73.1.6 300 mm
300 mm thick hollow core slab metre 1.008
26.73.1.7 350 mm
350 mm thick hollow core slab metre 1.176
26.73.1.8 400mm thick hollow core slab metre 1.344
26.73.2 Extra for using
Extra for using M-50
M-50 (Cement
(Cement content 425kg) instead
content 425kg) instead
of M-40
26.73.2.1
26.73.2.1 100 mm
100 mm thick hollow core slab metre 0.0225
26.73.2.2 120 mm
120 mm thick hollow core slab metre 0.027
26.73.2.3 150 mm
150 mm thick hollow core slab metre 0.03375
26.73.2.4 200 mm thick hollow core slab
200 mm metre 0.042
26.73.2.5 250 mm thick hollow core slab
250 mm metre 0.0525
26.73.2.6 300 mm
300 mm thick hollow core slab metre 0.063
26.73.2.7 350 mm
350 mm thick hollow core slab metre 0.0735
26.73.2.8 400mm thick hollow core slab metre 0.084
26.73.3 Extra for using
Extra for using M-60
M-60 (Cement
(Cement content 440kg) instead
content 440kg) instead
of M-40
26.73.3.1
26.73.3.1 100 mm
100 mm thick hollow core slab metre 0.036
26.73.3.2 120 mm
120 mm thick hollow core slab metre 0.0432
26.73.3.3 150 mm
150 mm thick hollow core slab metre 0.054
26.73.3.4 200 mm thick hollow core slab
200 mm metre 0.0672
26.73.3.5 250 mm thick hollow core slab
250 mm metre 0.084
26.73.3.6 300 mm
300 mm thick hollow core slab metre 0.1008
26.73.3.7 350 mm
350 mm thick hollow core slab metre 0.1176
26.73.3.8 400mm thick hollow core slab metre 0.1344
26.74 and maufacturing of
Fabrication and of solid precast concrete
element forwalls,stairs,column
for walls,stairs,column etc.,
370
Concrete grade M-35 (Cement content 370
26.74.1
26.74.1 kgs)
kgs) cum
cum 3.70
Extra for
for using M-40 (Cement content 400
400
26.74.2 kg)
kg) instaed
instaed of
of M-35
M-35 cum
cum 0.30
Extra for
for using M-50 (Cement content 425
425
26.74.3 kg)
kg) instaed
instaed of
of M-35
M-35 cum
cum 0.55
Extra for
for using M-60 (Cement content 440
440
26.74.4 kg)
kg) instaed
instaed of
of M-35
M-35 cum
cum 0.70
26.82 Providing
Providing and
and laying
laying rigid
rigid EPS
EPS (cellular
(cellular plastic
plastic material)
material)
blocks 100 sqm
100 sqm 8.38

422
422 COEFFICIENTS FOR CEMENT CONSUMPTION S.H.
FOR CEMENT S.H.:: 26.0 NEW
NEW TECHNOLOGIES
TECHNOI.OGIES AND
AND MATERIAL•S
MATERIALS
COEFFICIENTS
FOR BITUMEN
FOR
CONSUMPTION
1.0COEFFICIENTS FOR
1.0 FOR BITUMEN CONSUMPTION
16.0 ROAD WORK

Code Description Unit Quantity of bitumen


No.
No. per unit quantity of
per
work (Quintals)

SURFACE DRESSING
16.25 on new
Surface dressing on new surface with paving bitumen of
of
grade VG
grade VG -10.
-10. sqm
sqm 0.0225
16.26 Surface dressing on new surface in two
on new two coats with bitumen of
of
grade VG
grade VG -10.
-10. sqm
sqm 0.029
16.27 Surface dressing on
on old surface with hot bitumen of
of grade
VG -10.
VG -10. sqm
sqm 0.0195
16.28 Surface dressing one
one coat on
on new
new surface:
surface :
16.28.1
16.28.1 Using
Using bitumen emulsion
bitumen emulsion sqm
sqm 0.0195
16.29 Surface dressing one
one coat on
on old surface
surface::
16.29.1
16.29.1 Using
Using bitumen emulsion
bitumen emulsion sqm
sqm 0.0122
PREMIX CARPET
16.30 Providing
Providing and applying tack
and applying tack coat with bitumen
coat with of grade
bitumen of grade VG-
VG-
10::
10
16.30.1
16.30.1 On
On W.B.M.@ Kg// sqm
W.B.M. @ 0.75 Kg sqm sqm
sqm 0.0075
16.30.2 On
On bituminous surface@
surface @ 0.50 Kg
Kg// sqm
sqm sqm
sqm 0.0050
16.31
16.31 and applying tack coat using bitumen emulsion
Providing and
(Rapid
(Rapid Setting):
Setting):
16.31.1.1
16.31.1.1 On
On W.B.M@
W.B.M @ 0.4kg/sqm sqm
sqm 0.0040
16.31.1.2 On
On bituminous surface@
surface @ 0.25kg/sqm sqm
sqm 0.0025
16.32 22 cm
cm premix carpet surfacing
premix carpet with paving
surfacing with paving asphalt VG-10/VG-
asphalt VG-10/VG-
30/modified
30/modified bitumen
bitumen CRMB
CRMB 55.
55. sqm
sqm 0.0144
16.33 2.5 cm
2.5 cm premix carpet surfacing
premix carpet surfacing with
with paving
paving asphalt VG-10/
asphalt VG-10/
VG-30/modified bitumen
VG-30/modified bitumen CRMB
CRMB 55.55. sqm
sqm 0.018
16.34 22 cm
cm premix carpet surfacing with bitumen emulsion. sqm
sqm 0.0255*
16.35 2.5 cm
cm premix carpet surfacing with bitumen emulsion. sqm
sqm 0.0313*
16.36 Providing and Macadam::
and laying Bitumen Penetration Macadam
16.36.1
16.36.1 For 50mm compacted thickness with paving
For
asphalt VG-10@
asphalt VG-10 @ 50
50 kg/10 sqm
kg/10 sqm sqm
sqm 0.050
16.36.2 75 mm
For 75 mm compacted thickness in two
two layers
with paving
with asphalt VG-10@
paving asphalt VG-10 @ 68
68 kg/10 sqm
kg/10 sqm sqm
sqm 0.068
MASTIC AND
AND BITUMASTIC WEARING COURSE
16.37 Providing and
and laying bitumen mastic wearing course:
16.37.1
16.37.1 55 mm
mm thick sqm
sqm 0.0588
16.37.2 40 mm thick
40 mm sqm
sqm 0.0941
0.0941
16.38 2.5 cm
cm thick bitumastic sheet with hot bitumen, paving asphalt
VG-10/VG-30/modified bitumen
VG-10/VG-30/modified bitumen CRMB
CRMB 55. 55. sqm
sqm 0.0303
16.39 44 cm
cm thick bitumastic sheet with hot bitumen, paving asphalt
VG-10/VG-30/modified bitumen
VG-10/VG-30/modified bitumen CRMB
CRMB 55.55. sqm
sqm 0.0479

FOR BITUMEN CONSUMPTION S.H.


COEFFICIENTS FOR S.H.:: 16.0 ROAD WORK
WORK 425
Code Description Unit Quantity of bitumen
No.
No. per unit quantity of
per
work (Quintals)

SEAL COAT
16.40 P/L seal coat
P/L seal coat using
using 128
128 kg
kg of
of bitumen of grade
bitumen of grade VG-10.
VG-10. sqm
sqm 0.0077
16.41
16.41 P/L seal coat
P/L seal coat using 98 kg
using 98 kg of
of bitumen of grade
bitumen of grade VG-10.
VG-10. sqm
sqm 0.0098
16.54 macadam::
P/L Dense Bituminous macadam
16.54.1
16.54.1 50
50 to 100
100 mm
mm average compacted thickness
with bitumen
with of grade
bitumen of grade VG-30@
VG-30 @ 5%5% (percentage
(percentage
by weight of
by weight total mix)
of total mix) and
and lime filler @ @ 2%
lime filler 2%
(percentage
(percentage by weight of
by weight of Aggregate)
Aggregate) prepared
prepared
in Batch Type HotHot Mix
Mix Plant of 100-120 TPH TPH
capacity. cum
cum 1.1538
16.54.2 50 to 100
50 100 mm
mm average compacted thickness
with bitumen
with of grade
bitumen of grade VG-30@
VG-30 @ 5% 5% (percentage
(percentage
by weight of
by weight total mix)
of total mix) and
and lime filler @ @ 2%
lime filler 2%
(percentage
(percentage by weight ofAggregate)
by weight of Aggregate) prepared
prepared in in
Drum Type Hot
Hot Mix
Mix Plant of 60-90 TPH
TPH capacity. cum
cum 1.1538
16.55 Providing and
and laying Bituminous Macadam.
16.55.1
16.55.1 50
50 to 100
100 mm
mm average compacted thickness with
bitumen of grade
bitumen of grade VG-30@
VG-30 @ 3.50%
3.50% (percentage
(percentage
by weight of
by weight total mix)
of total mix) prepared
prepared inin Batch Type
Batch Type
Hot MixPlant of
Hot of 100-120 TPHTPH capacity. cum
cum 0.7683
16.55.2 50
50 to 100
100 mm
mm average compacted thickness with
bitumen of grade
bitumen of grade VG-30@
VG-30 @ 3.50%
3.50% (percentage
(percentage
by weight oftotal
by weight of total mix)
mix) prepared
prepared inin Drum Type Hot
Drum Type Hot
of 60-90 TPH
MixPlant of capacity.
TPH capacity. cum
cum 0.7683
16.56 Providing and
and laying Semi Dense Bituminous concrete
16.56.1
16.56.1 25
25 mmmm compacted thickness with bitumen of of
grade VG-30@
grade VG-30 @ 5% 5% (percentage
(percentage by weight of
by weight of
total mix)
total mix) and
and lime filler @ 2%
lime filler@ 2% (percentage
(percentage by
by
weight ofAggregate)
weight of Aggregate) prepared
prepared inin Batch Type Hot
Batch Type Hot
Mix Plant of 100-120 TPH
Mix capacity.
TPH capacity. 100 sqm
100 sqm 2.8846
16.56.2 25
25 mmmm compacted thickness with bitumen of of
grade VG-30@
grade VG-30 @ 5% 5% (percentage
(percentage by weight of
by weight of
total mix)
total mix) and
and lime filler @ 2%
lime filler@ 2% (percentage
(percentage by
by
weight of
weight Aggregate) prepared
ofAggregate) prepared inin Drum Type Hot
Drum Type Hot
Mix Plant of 60-90 TPH
Mix capacity.
TPH capacity. 100 sqm
100 sqm 2.8846
16.57 Concrete::
P/L Bituminous Concrete
16.57.1
16.57.1 40/50 mmmm compacted thickness with bitumen of of
grade VG-30@
grade VG-30 @ 5.5%5.5% (percentage
(percentage by weight of
by weight of
total mix)
total mix) and
and lime filler @ 3%
lime filler@ 3% (percentage
(percentage byby
weight ofAggregate)
weight of Aggregate) prepared
prepared inin Batch Type Hot
Batch Type Hot
Mix Plant of 100-
Mix 100-120
120 TPH capacity.
TPH capacity. cum
cum 1.2958
16.57.2 40/50 mmmm compacted thickness with bitumen of of
grade VG-30@
grade VG-30 @ 5.5%5.5% (percentage
(percentage by weight of
by weight of
total mix)
total mix) and
and lime filler @ 3%
lime filler@ 3% (percentage
(percentage byby
weight of
weight of Aggregate)
Aggregate) and waste plastic
and waste additive
plastic additive
@@ 8% 8% (percentage
(percentage by weight of
by weight of bitumen)
bitumen)
prepared in Batch Type Hot Hot Mix
Mix Plant of 100-120
TPH
TPH capacity. cum
cum 1.2958

426
426 FOR BITUMEN CONSUMPTION S.H.
COEFFICIENTS FOR S.H.:: 16.0
Y6.0 ROAD WORK
WORK
Code Description Unit Quantity of bitumen
No.
No. per unit quantity of
per
work (Quintals)

16.57.3 40/50 mmmm compacted thickness with bitumen of of


grade PMB-40
grade PMB-40@@ 5.5%5.5% (percentage
(percentage by weight
by weight
of total
of total mix)
mix) and
and lime filler @ 3%
lime filler@ 3% (percentage
(percentage by
by
weight ofAggregate)
weight of Aggregate) prepared
prepared in in Batch Type Hot
Batch Type Hot
Mix Plant of 100-120 TPH
Mix capacity.
TPH capacity. cum
cum 1.2958
16.57.4 40/50 mmmm compacted thickness with bitumen of of
grade CRMB-60
grade CRMB-60@@ 5.5%5.5% (percentage
(percentage by weight
by weight
of total
of total mix)
mix) and
and lime filler @ 3%
lime filler@ 3% (percentage
(percentage by
by
weight ofAggregate)
weight of Aggregate) prepared
prepared in in Batch Type Hot
Batch Type Hot
Mix Plant of 100-120 TPH
Mix capacity.
TPH capacity. cum
cum 1.2958
16.57.5 40/50 mm
mm compacted thickness with bitumen of of
grade VG-30@
grade VG-30 @ 5.5%
5.5% (percentage
(percentage by weight of
by weight of
total mix)
total mix) and
and lime filler @ 3%
lime filler@ 3% (percentage
(percentage by
by
weight ofAggregate)
weight of Aggregate) prepared
prepared in drum Type
in drum Type Hot
Hot
Mix Plant of 60-90 TPH
Mix capacity.
TPH capacity. cum
cum 1.2958
16.57.6 40/50 mmmm compacted thickness with bitumen of of
grade VG-30@
grade VG-30 @ 5.5%
5.5% (percentage
(percentage by weight of
by weight of
total mix)
total mix) and
and lime filler @ 3%
lime filler@ 3% (percentage
(percentage by by
weight of
weight of Aggregate)
Aggregate) and waste plastic
and waste plastic additive
additive
@@ 8% 8% (percentage
(percentage by weight of
by weight of bitumen)
bitumen)
prepared in drum Type Hot Hot Mix
Mix Plant of 60-90
TPH
TPH capacity.
capacity. cum
cum 1.2958
16.57.7 40/50 mmmm compacted thickness with bitumen of of
grade PMB-40
grade PMB-40@@ 5.5%5.5% (percentage
(percentage by weight
by weight
of total
of total mix)
mix) and
and lime filler @ 3%
lime filler@ 3% (percentage
(percentage by
by
weight ofAggregate)
weight of Aggregate) prepared
prepared in drum Type
in drum Type Hot
Hot
Mix Plant of 60-90 TPH
Mix capacity.
TPH capacity. cum
cum 1.2958
16.57.8 40/50 mmmm compacted thickness with bitumen of of
grade CRMB-60
grade CRMB-60@@ 5.5%
5.5% (percentage
(percentage by weight
by weight
of total
of total mix)
mix) and
and lime filler @ 3%
lime filler@ 3% (percentage
(percentage by
by
weight of
weight Aggregate) prepared
ofAggregate) prepared in in Drum Type Hot
Drum Type Hot
Mix Plant of 60-90 TPH
Mix capacity.
TPH capacity. cum
cum 1.2958

** Including tack coat

FOR BITUMEN CONSUMPTION S.H.


COEFFICIENTS FOR S.H.:: 16.0 ROAD WORK
WORK 427
427
FOR BITUMEN CONSUMPTION
1.0 COEFFICIENTS FOR
22.0 WATER PROOFING

No.
Code No. Description Unit Quantity of bitumen
per unit quantity of
per
work (Quintals)
SURFACE DRESSING
22.3 P/L water proofing
P/L water treatment to
proofing treatment to vertical
vertical and
and horizontal
horizontal
surfaces of depressed portions of W.C., kitchen and and the
like. sqm
sqm 0.0170
22.6 P/L water proofing
P/L water treatment on
proofing treatment on roofs with cement
roofs with slurry
cement slurry
& & fibre
fibre glass
glass cloth.
cloth. sqm
sqm 0.0097
22.8 P/L four courses
P/L four water proofing
courses water treatment with
proofing treatment with bitumen
bitumen
felt over roofs:
22.8.1
22.8.1 Bitumen
Bitumen feltfelt (hessian
(hessian base)type
base)type33 gradeI
grade I sqm
sqm 0.0290
22.9 P/L six courses water proofing treatment with bitumen
P/L six courses water proofing treatment with bitumen
felt over roofs applied hot hot@@ 1.45, 1.20
1.20&& 1.45 forfor 1st,
3rd
3rd and Sth course.
and 5th sqm
sqm 0.041
0.041
22.10&&
22.10 P/L six courses
P/L six courses waterwater proofing treatment with
proofing treatment with bitumen
bitumen
22.11
22.11 felt over roofs applied hot hot@@ 1.45, 120120 && 1.70 forfor 1st,
3rd
3rd and
and 5thSth course. sqm
sqm 0.0435
22.15 P/L
P/L in situ seven
in situ seven course
course water
water proofing treatment with
proofing treatment with
APP (1.5
APP (1.5 mm thick @ 2.25
mm thick@ 2.25 kg./sqm).
kg./sqm). sqm
sqm 0.036
22.16 P/L
P/L inin situ five course
situ five water proofing
course water treatment with
proofing treatment with APP
APP
(2.00
(2.00 mm thick @ 3.00
mm thick@ 3.00 kg./sqm).
kg./sqm). sqm
sqm 0.024
22.17 P/L
P/L in situ seven
in situ seven course
course water
water proofing treatment with
proofing treatment with
APP (2.00
APP (2.00 mm thick @ 3.00
mm thick@ 3.00 kg./sqm).
kg./sqm). sqm
sqm 0.0360
22.18 P/F APP.
22.18.1 22 mm
22.18.1 mm (for corrugated roof
(for corrugated roof sheets)
sheets) sqm
sqm 0.0035
22.19 P/L APP modified
P/L APP modified prefabricated five layer,
prefabricated five layer,3 3 mm thick
mm thick
water proofing
water proofing membrane. Tear strength
membrane. Tear strength inin longitudinal
longitudinal
and
and transverse direction as
as 60/80N.
22.19.1
22.19.1 33 mmmm thick sqm
sqm 0.0035
22.20 P/L APP modified
P/L APP modified prefabricated five layer
prefabricated five layer33 mm thick
mm thick
water proofing
water proofing membrane. Tear strength
membrane. Tear strength in
in longitudinal
longitudinal
and
and transverse direction as
as 300/250N.
22.20.1
22.20.1 33 mm
mm thick sqm
sqm 0.0035

428
428 COEFFICIENTS FOR S.H.:: 22.0 WATER PROOFING
FOR BITUMEN CONSUMPTION S.H.