英语
NEW
Grid-Tied Inverters
S6-GR3P(3-10)K02-NV-ND
2 MPPT | 21A per MPPT
 •   String current up to 21A                       •   Nighttime PID recovery function (optional)
 •   > 200% DC/AC ratio                             •   IP66, C5 Anti-Corrosion Level
 •   Dual independent RS485 ports, supporting       •   Information scrolling display, easy access to inverter
     communication with multiple devices                operation information
 •   24-hour load consumption monitoring            •   Adaptive weak grid
GINLONG TECHNOLOGIES CO., LTD.
w: solisinverters.com         
[email protected]DATASHEET                                                                             S6-GR3P(3-10)K02-NV-ND
Models                                        3K                4K                        5K                   6K                     8K             9K               10K
Input DC
Recommended max. PV power                   4.5 kW             6 kW                     7.5 kW                 9 kW               12 kW            13.5 kW            15 kW
Max. input voltage                                                                                            1100 V
Rated voltage                                                                                                  600 V
Start-up voltage                                                                                               160 V
MPPT voltage range                                                                                         160 - 1000 V
Max. input current                                                                                          21 A / 21 A
Max. short circuit current                                                                                26.5 A / 26.5 A
MPPT number / Max. input strings number                                                                        2/2
Output AC
Rated output power                           3 kW              4 kW                      5 kW                  6 kW                   8 kW          9 kW              10 kW
Max. apparent output power                   3 kVA             4 kVA                     5 kVA                 6 kVA                  8 kVA         9 kVA            10 kVA
Max. output power                            3 kW              4 kW                      5 kW                  6 kW                   8 kW          9 kW              10 kW
Rated grid voltage                                                                            3/N/PE, 220 V / 380 V, 230 V / 400 V
Rated grid frequency                                                                                      50 Hz / 60 Hz
Rated grid output current                 4.6 A / 4.3 A     6.1 A / 5.8 A             7.6 A / 7.2 A        9.1 A / 8.7 A      12.2 A / 11.5 A   13.7 A / 13.0 A   15.2 A / 14.4 A
Max. output current                       4.6 A / 4.3 A     6.1 A / 5.8 A             7.6 A / 7.2 A        9.1 A / 8.7 A      12.2 A / 11.5 A   13.7 A / 13.0 A   15.2 A / 14.4 A
Power factor                                                                                     > 0.99 (0.8 leading - 0.8 lagging)
THDi                                                                                                           < 3%
                                                                                                            y
Efficiency
                                                                                                          r
Max. efficiency                                                             98.3%                                                                   98.5%
                                                                                                        a
EU efficiency                                                               97.7%                                                                   97.9%
Protection
                                                                  i                                   n
DC reverse-polarity protection                                                                                  Yes
Short circuit protection                                                                                        Yes
                                                               im
Output over current protection                                                                                  Yes
                                             l
Surge protection                                                                                                Yes
                                          re
Grid monitoring                                                                                                 Yes
Anti-islanding protection                                                                                       Yes
                                      P
Temperature protection                                                                                          Yes
I/V Curve scanning                                                                                              Yes
Multi peak scan                                                                                                 Yes
Integrated AFCI 2.0                                                                                          Optional
Integrated PID recovery                                                                                      Optional
Integrated DC switch                                                                                            Yes
General Data
Dimensions (W × H × D)                                                                                 355 × 410 × 179 mm
Weight                                                                      14.7 kg                                                                15.4 kg
Topology                                                                                                 Transformerless
Self-consumption (night)                                                                                       <1W
Operating ambient temperature range                                                                        -25 ~ +60°C
Relative humidity                                                                                            0 - 100%
Ingress protection                                                                                             IP66
Noise emission (typical)                                                                                    < 30 dB(A)
Cooling concept                                                                                          Natural cooling
Max. operation altitude                                                                                       4000 m
                                               G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 /
Grid connection standard
                                             UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530
Safety / EMC standard                                                                  IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
Features
DC connection                                                                                            MC4 connector
AC connection                                                                                         Quick connection plug
Display                                                                                     LED digital display & Bluetooth + APP
Communication                                                                                     RS485, Optional: Wi-Fi, GPRS