Fire Suppression

General Products Catalogue

Automatic Sprinklers
System Valves & Devices
Piping & Electrical Products
Specialty Systems

Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

FIRE SUPPRESSION
General Products Catalogue
Johnson Controls leads the industry in water-based fire suppression products, offering one of the
broadest product lines globally. Through ongoing, world-class research and development, we’re
continually expanding our capabilities. Our solutions include brands that have led the fire protection
industry for decades — with over 150 years in the industry, we are uniquely qualified to deliver cost-
effective solutions customized to any building configuration and fire protection application.
The Johnson Controls team is committed to delivering products with dependable performance that
have received independent approvals and certifications from industry agencies globally. Our state-
of-the-art, international manufacturing facilities have all been granted ISO 9000 approvals and are
routinely audited by independent testing agencies for quality and conformance. We also participate
in many committees and several international standards and code-making bodies.
The Johnson Controls fire suppression offering includes leading brands from across the fire
protection industry with decades of industry knowledge and expertise. The brands leverage the
global reach of Johnson Controls to bring customers effective solutions for a variety of applications.

TechXchange Academy
The state-of-the-art TechXchange academy offers on-site and online training courses to equip
students with work-relevant training and on-the-job performance. These solutions, when applied in
the workplace, increase the ability of our graduates to better create value for their organization and
their customers.
It offers various training courses on topics such as Sprinkler Systems, WaterMist System and
SprinkCAD Software.
To learn more, please visit www.onlinetechxchange.com

10 Year Limited Warranty


We have the unique distinction of standing behind the fire suppression products we manufacture
by offering a 10 year limited warranty. This exhibits our commitment to product quality worldwide.
Please see the General Terms and Conditions of Sale at www.tyco-fire.com.

Click on the brands to find out more.

II
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
TABLE OF CONTENTS
SprinkCAD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VIII
1. SPRINKLERS
Standard Spray Sprinklers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–1 to 1–26
Extended Coverage Sprinklers . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–27 to 1-43
Storage Sprinklers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-44 to 1-78
RAPID RESPONSE® Residential Sprinklers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-79 to 1-94
Dry Sprinklers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-95 to 1-118
Special Application Sprinklers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-119 to 1-159
Sprinkler Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-160 to 1-167
Nozzles & Nozzle Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-168 to 1-188
2. Watermist System
Aquamist ULF System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Aquamist FOG System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Aquamist SONIC System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
3. SYSTEM VALVES & DEVICES
Wet System Valves & Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 to 3-14
Dry System Valves & Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15 to 3-34
Deluge & Preaction Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-35 to 3-62
4. GENERAL PURPOSE VALVES
General Purpose Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 to 4-72
Other Pump Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-73 to 4-84
5. MEASURING AND ELECTRICAL DEVICES
System Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Flow Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 to 5-10
Pressure Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11 to 5-20
Supervisory Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21 to 5-24
Monitor Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25 to 5-26
Flow Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27 to 5-30
Water Tank Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-31 to 5-38
6. Tyco CPVC Pipe & Fittings
CPVC Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 to 6-39
7. MLC-S Sprinkler Pipe and Fittings
MLC-S Sprinkler Pipe Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 to 7-16
8. Flexible Hose, Welding Outlets & Fittings
Flexible Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1 to 8-5
Drop Nipples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6 to 8-7
Branch Outlets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-8 to 8-12
9. Hoses and Hose Reels
Hose Reels & Cabinets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1 to 9-6
Hoses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-7 to 9-8
10. Grooved Piping Products
Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1 to 10-11
Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-12 to 10-32
11. Corrosion Solutions
Nitrogen Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-2 to 11-3
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-4 to 11-16
12. Index
Keyword or Model Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-1 to 12-6
All metric measurements throughout this Catalogue are based on U.S. standard-to-metric conversions. Metric specifications may vary
from country to country.

www.tyco-fire.com III
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

1. Sprinklers CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–131


CC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–132
Standard Spray Sprinklers
CC3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–133
TY-B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–2 to 1–7
Issue D Quartzoid® . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–134
TY-FRB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–9 to 1–16
TY-FRFS, TY-FS & TY-FS Special . . . . . . . . . . 1–135 to 1–136
RFII. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–17
TY-B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–137 to 1–142
RFII-MRI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–18
TY-FRB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–143 to 1–147
TY-L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–19 to 1–21
TY-B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–147 to 1–149
TY-FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–22 to 1–24
FTR-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–150
RFII-HSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–25
TY-L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–151
ILLUSION™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–26
TY-B & TY-FRB
Extended Coverage Sprinklers (Alternate Materials of Construction) . . . . . . . 1–152 to 1–154
EC-25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–28 TY-B & TY-FRB (Poly-Stainless) . . . . . . . . . . . 1–155 to 1–156
EC-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–29 MJCS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–157
EC-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–29 to 1–30 MJCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–158
EC-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–31 MJC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–159
EC-8C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–32
Sprinkler Accessories
EC-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–33 to 1–34
Escutcheon Plates. . . . . . . . . . . . . . . . . . . . . . 1–161 to 1–164
TY-FRB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–35 to 1–36
Sprinkler Head Cabinet. . . . . . . . . . . . . . . . . . 1–165 to 1–167
ELO SW-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–37
ELO SW-24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–37 Nozzle & Nozzle Accessories
TY-FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–38 MV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–169 to 1–170
CHEC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–39 Sealed MV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–171
ELOC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–40 MV-T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–172
RFII. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–41 MV-R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–173
RFII-MRI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–42 Type A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–174
RFIII. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–43 Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–175
Issue A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–176
Storage Sprinklers
Issue B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–176
ESFR-34 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–45
D3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–177
EC-25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–46
D3S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–178
ESFR-25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–47
HV ”High Velocity” . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–179
ESFR-22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–48
EA-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–180
ESFR-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–49 to 1–53
TN-25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–181
ESFR-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–54
TN-17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–182
ULTRA K-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–55 to 1–56
D4a. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–183
K17-231. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–57
F822 thru F834 Mulsifyre®. . . . . . . . . . . . . . . . . . . . . . . 1–184
ELO-231B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–58 to 1–59
F822S thru F834S Mulsifyre®. . . . . . . . . . . . . . . . . . . . . 1–185
ELO-231 FRB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–60
Cooling Tower Nozzle. . . . . . . . . . . . . . . . . . . . . . . . . . 1–186
ELO-231. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–61 to 1–62
B-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–187
LD "Large Drop" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–63
TY-B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–64 to 1–66
2. Watermist Systems
TY-FRB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–67 to 1–69
Aquamist ULF System. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
TY-L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–70 to 1–71
Aquamist FOG System. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
TY-FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–72 to 1–73
Aquamist Sonic System. . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Sprinkler Guards. . . . . . . . . . . . . . . . . . . . . . . . . 1–74 to 1–78
RAPID RESPONSE® Residential Sprinkler Systems 3. System Valves & Devices
LFII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–80 to 1–90
LFII NFPA 13 Optimised Sprinklers. . . . . . . . . . . 1–91 to 1–93 Wet Pipe Sprinkler Systems
RCP-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–94 AV-1-300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 to 3-3
AV-1-300 Wet System Valve Assemblies
Dry Sprinklers
with FM Trim. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
DS-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–96 to 1–101
AV-1-300 Wet System Valve Assemblies
DS-1 Stainless Steel . . . . . . . . . . . . . . . . . . . . 1–102 to 1–105
with CE/FM Trim. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
DS-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–106 to 1–107
AV-1-300 Supervised Wet System Valve
DS-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–108 to 1–111 Assemblies with CE/FM Trim. . . . . . . . . . . . . . . . . . . . . . 3-6
DS-C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–112 to 1–113 AV-1-300 Wet System Valve Assemblies
DS-ECC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–114 to 1–115 with CE/VdS Trim . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
DS-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–116 to 1–117 RC-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
DSB-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–118 CV-1FR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
G5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–118 RSV-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10
Special Application Sprinklers RM-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
Attic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–120 to 1–121 RM-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
RAVEN Studio Sprinkler. . . . . . . . . . . . . . . . . . 1–122 to 1–123 TD-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
RAVEN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–124 to 1–125 WMA-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14
FSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–126 Dry Pipe Sprinkler Systems
TFP PH2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–127 DPV-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
TFP PH5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–128 Dry System Valve Assemblies DPV-1
CWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–129 with FM Trim DN65-100 . . . . . . . . . . . . . . . . . . . . . . . . . 3-18
WS™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–130

IV
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry System Valve Assemblies DPV-1 Model 601. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-32
with FM Trim DN150. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19 Model 126S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-32
Dry System Valve Assemblies DPV-1 CV-1F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-33 to 4-34
with CE/VdS Trim DN100. . . . . . . . . . . . . . . . . . . . . . . . . 3-20 CV-1FR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35 to 4-36
Dry System Valve Assemblies DPV-1 Model TJCV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-37
with CE/VdS Trim DN150. . . . . . . . . . . . . . . . . . . . . . . . . 3-21 Model 8800. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-38
Dry System Valve Assemblies DPV-1 Model C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-39
with CE/FM Trim DN65-100. . . . . . . . . . . . . . . . . . . . . . . 3-22 Model 85. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-40
Dry System Valve Assemblies DPV-1 Model Reto Stop. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-41
with CE/FM Trim DN150. . . . . . . . . . . . . . . . . . . . . . . . . . 3-23 Model 62S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-42
Alternate Valve Assemblies, Model LPC Trim . . . . . . . . . 3-24 Model N5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-43
ACC-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25 Model TJST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-44
QRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26 760P. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-45
AMD-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-27 F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-46
AMD-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-28 807. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-47
AMD-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29 74A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-48
LE020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30 557 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-49
Model G16AC812. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-31 Super Centurion Straight. . . . . . . . . . . . . . . . . . 4-50 to 4-51
Model AB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-32 Super Centurion Duck Foot. . . . . . . . . . . . . . . . 4-52 to 4-53
Model CCS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-33 Model A-373. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-54
Removed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34 Model 70B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-55
Deluge & Preaction Systems Saphir. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-56
DV-5A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-36 to 3-37 EMERAUDE CS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-57
DP-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-38 Model 1000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-58
Solenoid Valve . . . . . . . . . . . . . . . . . . . . . . . . . 3-39 to 3-40 Model A59. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-59
Solenoid Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-40 Model A61. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-60
MC-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-41 Test Kit - Sprinklers . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-61
AD-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-42 Test Kit - Flow Switches. . . . . . . . . . . . . . . . . . . . . . . . 4-62
AD-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-43 Model BH-19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-63
Deluge Systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-44 RV-1A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-64 to 4-65
DV-5A Deluge Systems, Wet Pilot. . . . . . . . . . . . . . . . . 3-45 Model 7000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-66
DV-5A Deluge Systems, Dry Pilot . . . . . . . . . . . . . . . . . 3-46 Model 55L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-67
DV-5A Deluge Systems, Electric Actuation. . . . . . . . . . . 3-47 A201 - Angle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-68
DV-5A Deluge Systems, Remote Resetting. . . . . . . . . . 3-48 A203 - Globe. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-68
DV-5A Deluge Systems, Remote Resetting, A202 - Angle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-69
Pressure Reducing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-49 A204 - Globe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-69
Model BW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-50 MONOSTAB A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-70
Single Interlock Preaction Systems. . . . . . . . . . . . . . . . . 3-51 PRV-1A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-71
DV-5A Single Interlock Preaction System, Wet Pilot. . . . 3-52 PRV-1 - Angle Style. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-72
DV-5A Single Interlock Preaction System, Dry Pilot. . . . . 3-53
Other Pump Equipment
DV-5A Single Interlock Preaction System,
Model 15A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-73
Electric Actuation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-54
Model 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-74
Double Interlock Preaction Systems . . . . . . . . . . . . . . . . 3-55
Model 302. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-74
DV-5A Double Interlock Preaction System,
FV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-75
Electric/Electric Actuation. . . . . . . . . . . . . . . . . . . . . . . . 3-56
Model BAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-76
DV-5A Double Interlock Preaction System,
Model EA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-77
Electric/Pneumatic Actuation . . . . . . . . . . . . . . . . . . . . . 3-57
Model 109. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-78
DV-5A Double Interlock Preaction System, Type A . . . . . 3-58
Model SV1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-79
DPV-1 Preaction, Type B Valves EN12845 Compliance. . . 3-59
Model SV642. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-80
Spare Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-60
Model RAF13. . . . . . . . . . . . . . . . . . . . . . . . . . . 4-81 to 4-82
Fire Department Connections. . . . . . . . . . . . . . . . . . . . . 3-61
K3-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-83 to 4-84
Hangers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-61
4410-RC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-61
5. Measuring and Electrical Devices
4. General Purpose Valves System Testing
SprinklerSense . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
General Purpose Valves
BFV-300 Grooved End Butterfly Valve. . . . . . . . . . 4-2 to 4-5 Flow Switches
BFV-300 Wafer Style Butterfly Valve . . . . . . . . . . 4-6 to 4-8 VSR-AT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
BFV-300 - Hydraulic Actuator, TruTorq. . . . . . . . 4-9 to 4-10 VSR-EU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
BFV-300 - Electric Actuator. . . . . . . . . . . . . . . . 4-11 to 4-13 VSG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
Model Infinity / 05-47 Series Resilent VS-SP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
Gate Valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14 to 4-17 VSR-S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7
Model TJR Resilient-Seated Gate Valves. . . . . . . 4-18 to 4-21 VSR-FE-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8
Model TJP Resilient-Seated Gate Valves. . . . . . . 4-22 to 4-25 VSR-FEX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9
Model TJP Vertical Indicator Post. . . . . . . . . . . . 4-26 to 4-27 ZONECHECK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10
Model TJP Cross Wall Indicator Post. . . . . . . . . 4-28 to 4-29 Pressure Switches
Model 4908. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-30 PS10-1 or PS10-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
Model 1610 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-31 PS40-1 or PS40-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-12

www.tyco-fire.com V
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

PS100-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13 8. Flexible Hose, Welding Outlets & Fittings


PS120-1 or PS120-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-14
Flexible Hose
FF4-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15
Fastflex Flexible Sprinkler Hose Assembly. . . . . . . . . . . . . 8-2
PS10-EX or PS40-EX . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16
Fastflex Sprinkler Accessories. . . . . . . . . . . . . . . . 8-3 to 8-5
ADPS-300-1B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17
RT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18 Drop Nipples
PUMP BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19 Longneck Reduced Ends . . . . . . . . . . . . . . . . . . . . . . . . . 8-6
CUSP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-20 M & F Drop Nipples. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-7

Supervisory Switches Branch Outlets


PCVS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21 Tee-Let Branch Outlets Threaded. . . . . . . . . . . . . . . . . . 8-8
OSYSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-22 C-Let Branch Outlets Non-Chamfered. . . . . . . . . . . . . . . 8-9
PIVS-U-EX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23 Welding Branchlets Branch Outlets Grooved. . . . . . . . . . 8-10
OSYS-U-EX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-24 Permabond Pipe Thread Sealant. . . . . . . . . . . . . . . . . . . 8-11

Monitor Switches 9. Hoses and Hose Reels


Fig. I88 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25
BIGGY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-26 Hose Reels & Cabinet
Swinging Hose Reels. . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–2
Flow Meters
Fixed Reel Hose Reels. . . . . . . . . . . . . . . . . . . . . . . . . . . 9–3
VENTURI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27
Swinging Reel In Cabinet Hose Reels. . . . . . . . . . . . . . . . 9–4
MAGFLO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-28
Series 2500 Hose Rack Assemblies. . . . . . . . . . . . . . . . . 9–5
Turbo-Lux3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-29
Series 1054 Hose Rack Assemblies. . . . . . . . . . . . . . . . . 9–6
INFLUX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-30
Hoses
Water Tank Equipment
Viking Hoses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–7
FST-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-31
Saxon Hoses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–8
FST-B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-32
FEEDING TANK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-33
FLOAT SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-34
10. Grooved Piping Products
FEEDING DEVICE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-34 Couplings
PROVING PIPES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-35 Figure 577 Rigid Coupling . . . . . . . . . . . . . . . . . . . . . . . 10–2
GAUGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-36 Figure 705 Flexible Coupling . . . . . . . . . . . . . . . . . . . . . 10–3
MAXANTKIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-37 Figure 707 Flexible Coupling . . . . . . . . . . . . . . . . . . . . . 10–4
PBA-AC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-38 Figure 716 Flexible Reducing Coupling. . . . . . . . . . . . . . 10–5
Figure 577, 579, 705, 707 Replacement Gaskets. . . . . . . 10–6
6. Tyco CPVC Pipe & Fittings Figure 716 Replacement Gaskets. . . . . . . . . . . . . . . . . . 10–7
Figure 71 Flange Adapter. . . . . . . . . . . . . . . . . . . . . . . . 10–8
CPVC Pipe & Threaded Fittings
Figure 71 ANSI Flange. . . . . . . . . . . . . . . . . . . . . . . . . . 10–9
CPVC Sprinkler Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
Flange Adapter Washers. . . . . . . . . . . . . . . . . . . . . . . 10–10
CPVC Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 to 6-33
Figure 71 Replacement Gaskets. . . . . . . . . . . . . . . . . . . 10–11
CPVC Elbows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 to 6-5
Figure 343 & 344 Flange Adapters. . . . . . . . . . . . . . . . . 10–12
CPVC Tees. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6, 6-12
CPVC Cross. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 to 6-8 Fittings
CPVC Coupling. . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9 to 6-10 Figure 510 90° Elbows. . . . . . . . . . . . . . . . . . . . . . . . . 10–13
CPVC End Cap. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-11 Figure 501 45° Elbows. . . . . . . . . . . . . . . . . . . . . . . . . 10–14
CPVC Bush Reducing. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-13 Figure 519 Tees. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–15
CPVC Coupling Adaptor. . . . . . . . . . . . . . . . . . . . . . . . . . 6-14 Figure 260 End Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–16
CPVC Threaded Adaptor. . . . . . . . . . . . . . . . . . . 6-15 to 6-16 Figure 510S Short Pattern 90° Elbows. . . . . . . . . . . . . . 10–17
CPVC Sprinkler Head Adaptor. . . . . . . . . . . . . . . 6-17 to 6-22 Figure 519S Short Pattern Tees. . . . . . . . . . . . . . . . . . 10–18
CPVC Back-to-Back Sprinkler Head Figure 212 / 312 22-1⁄2° Elbows. . . . . . . . . . . . . . . . . . . 10–19
Tee or Cross . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-23 to 6-24 Figure 211 / 311 11-1⁄4° Elbows . . . . . . . . . . . . . . . . . . 10–20
CPVC Raven Studio Sprinkler Adapters. . . . . . . . 6-25 to 6-26 Figure 221 / 321 Reducing Tees. . . . . . . . . . . . . . . . . . . 10–21
CPVC Rapid Seal Adapter (RSA). . . . . . . . . . . . . . 6-27 to 6-33 Figure 221 / 321 - Reducing Tees. . . . . . . . . . . . . . . . . 10–22
CPVC Riser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-34 Figure 250 / 350 Concentric Reducers. . . . . . . . . . . . . 10–23
CPVC Flow Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-35 Figure 250 / 350 - Concentric Reducers. . . . . . . . . . . . 10–24
CPVC Cement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-36 Figure 322 Reducing Tees . . . . . . . . . . . . . . . . . . . . . . 10–25
CPVC Dauber. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-36 Figure 222 Hydrant Tee. . . . . . . . . . . . . . . . . . . . . . . . 10–26
CPVC Pipe Cutter Tool. . . . . . . . . . . . . . . . . . . . . . . . . . . 6-36 Figure 522 G-FIRE Threaded Sprinkler Outlet . . . . . . . . 10–27
CPVC Deburring Tools. . . . . . . . . . . . . . . . . . . . . . . . . . . 6-37 Figure 730 Mechanical Tees BSP Threads . . . 10–28 to 10–29
CPVC Test Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-37 Figure 730 Mechanical Tees Grooved . . . . . . 10–30 to 10–31
CPVC Thread Sealant. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-38 Figure 730 & 522 Replacement Gaskets. . . . . . . . . . . . 10–32
CPVC Caulk & Walk®. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-38
CPVC Hangers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-39 11. Corrosion Solutions
Nitrogen Generators
7. MLC-S Sprinkler Pipe and Fittings Model NG-1 100, NG-1 250, and NG-1 500
MLC-S Sprinkler Pipe. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2 Wall-Mounted Nitrogen Generator . . . . . . . . . . . . . . . . . 11–2
MLC-S Press Fittings. . . . . . . . . . . . . . . . . . . . . . . 7-3 to 7-10 Model NG-1 1150, NG-1 1500, NG-1 2000, and
MLC-S Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11 to 7-16 NG-1 3000 Stand-Alone Nitrogen Generator. . . . . . . . . . 11–3
MLC-S Universal Casting Cup. . . . . . . . . . . . . . . 7-15 to 7-16

VI
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Accessories
Model TILD In-Line Corrosion Detector. . . . . . . . . . . . . 11–4
Model TAV-D Manual Air Vent - Dry Systems. . . . . . . . . 11–5
Model TSV-D SMART Air Vent - Dry Systems . . . . . . . . 11–6
Model TAV-W Automatic Air Vent - Wet Systems. . . . . . 11–7
Model TAV-WN Air Vent, Wet - Nitrogen . . . . . . . . . . . . 11–8
Model TNIP Nitrogen Injection Port. . . . . . . . . . . . . . . . . 11–9
Model TRIS Remote Inerting Station. . . . . . . . . . . . . . . 11–10
Model THGA Handheld Gas Analyzer. . . . . . . . . . . . . . . 11–11
Model TGSP Gas Sampling Port. . . . . . . . . . . . . . . . . . . 11–12
Model TGSK Gas Sampling Kit. . . . . . . . . . . . . . . . . . . . 11–13
Model TNIM Nitrogen Inerting Manifold. . . . . . . . . . . . . 11–14
Model TNIC Nitrogen Interface Controller. . . . . . . . . . . 11–15
Model TSGA SMART Gas Analyzer. . . . . . . . . . . . . . . . . 11–16
12. Index
Keyword and Model Index. . . . . . . . . . . . . . . . . . 12-1 to 12-6
Contact Information . . . . . . . . . . . . . . . . . . . . . . Back Cover

www.tyco-fire.com VII
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Advanced Software for the Fire Protection Professional


SprinkCAD™ 3D
Users can design in full-3D using fast, accurate drawing and editing tools

SprinkCODE™ Connect
This web-based, interactive code guide includes multiple editions of NFPA and EN codes

SprinkCALC
Perform hydraulic calculations and easily share them with an approving authority

SprinkFDT
This tool is the only UL Listed software for calculating fluid delivery time to optimize
dry system design

SprinkSLIC
Users can create and interpret pipe fabrication schedules utilizing this standalone
stocklisting software

REVIT® Tools for SprinkCAD


Optional add-on tools for use with SprinkCAD 3D™ or Classic help simplify Revit® design

VIII
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Standard Spray Sprinklers
Offered in a wide range of standard and quick response options for light and ordinary hazard occupancies.
- Airports - Museums

- Assembly Spaces - Prisons

- Banks - Retail

- Colleges/Universities - Schools

- Hospitals/Clinics - Theaters

- Hotels - Transportation Terminals

- Libraries

www.tyco-fire.com 1–1
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Standard Spray Sprinklers


TY-B
Upright, Pendent, & Recessed Pendent
K Factor K= 40 (2.8) • K= 80 (5.6) • K= 115 (8.0)
1
Thread Size ⁄2" NPT • 3 ⁄ 4" NPT
K=40 – UL, C-UL, FM, NYC
Approvals K=80 – UL, C-UL, FM, CE, VdS
K=115 – UL, C-UL, FM, NYC, LPCB, VdS
57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),
Temperature
141°C (286°F), 182°C (360°F), Open
K=80 – Style 15, Style 20
Escutcheon
K=115 – Style 10, Style 40
Signal White, Pure White, Jet Black, Chrome Plated,
Escutcheon Finish
Natural Brass
Natural Brass, Chrome Plated, Pure White,
Sprinkler Finish Signal White, Jet Black, Poly-Stainless, Lead Coated,
Wax Coated, Wax over Lead Coated
TY1151, TY1251, TY315, TY325, TY3151, TY3251
SIN
TY4151, TY4251, TY4851, TY4951

Wrench Type W-TYPE 6 / W-TYPE 7 (for recessed escutcheons)

Tech Data Sheet K=40, K=80, & K=115 – TFP151 / K=80 – TFP152

All hazard • 5 mm bulb • Small frame, narrow profile bulb • Discharges a hemispherical water spray pattern in the area beneath
the sprinkler • Designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls,
factories, refineries, chemical plants, etc.

TY-B, K=40 (2.8), 1 ⁄ 2" NPT


K=40 [2.8] • 1 ⁄ 2” NPT • TFP151
Part No. Temperature Approvals & Listings
Upright • K=40 [2.8]
1 Finish
⁄ 2” NPT • SIN TY1151 Upright Pendent
FM

°C °F Code

UL
SIN TY1151 SIN TY1251

575301135 575311135 57 135 1 √ √


575301155 575311155 68 155 1 √ √
575301175 575311175 79 175 1 √ √
55,6 mm
575301200 575311200 93 200 1 √ √
(2-3/16")
575301286 575311286 141 286 1 √ √
575301360 575311360 182 360 1 - √
575303135 575313135 57 135 3 √ √
575303155 575313155 68 155 3 √ √
575303175 575313175 79 175 3 √ √
575303200 575313200 93 200 3 √ √
Pendent • K=40 [2.8] 575303286 575313286 141 286 3 √ √
1
⁄ 2” NPT • SIN TY1251 575303360 575313360 182 360 3 - √
575304135 575314135 57 135 4 √ √
575304155 575314155 68 155 4 √ √
575304175 575314175 79 175 4 √ √
575304200 575314200 93 200 4 √ √
57,2 mm
(2-1/4") 575304286 575314286 141 286 4 √ √
575304360 575314360 182 360 4 - √
575309135 575319135 57 135 9 √ √
575309155 575319155 68 155 9 √ √
575309175 575319175 79 175 9 √ √
575309200 575319200 93 200 9 √ √
575309286 575319286 141 286 9 √ √
575309360 575319360 182 360 9 - √

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal Polyester RAL9003, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–2
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Standard Spray Sprinklers
TY-B
Upright, Pendent, & Recessed Pendent (Cont.)

TY-B, K=80 (5.6), 1 ⁄ 2" NPT K=80 [5.6] • 1⁄ 2” NPT • TFP151


Part No. Temp. Approvals & Listings

Belarusian
Ukrainian

Academy
of Russia
Upright Pendent Finish
Upright • K=80 [5.6]

LPCB

MED
SAS

VKF
VdS

Fire
FM
SIN SIN

UL

CE
1 °C °F Code
⁄ 2” NPT • SIN TY3151
TY3151 TY3251

575701135 575711135 57 135 1 √ √ √♦ √ √ √ √ U √ √ √


575701155 575711155 68 155 1 √ √ √♦ √ √ √ √ U √ √ √
55,6 mm 575701175 575711175 79 175 1 √ √ √♦ √ √ √ √ U √ √ √
(2-3/16") 575701200 575711200 93 200 1 √ √ √♦ √ √ √ √ U √ √ √
575701286 575711286 141 286 1 √♦ √ √♦ √♦ √ √ √ U √ √ √
575701360 575711360 182 360 1 √♦ √♦ √♦ √♦ √ √ √ U √ √ √
575702135 575712135 57 135 2 - √ - - √ √ √ U √ √ √
575702155 575712155 68 155 2 - √ - - √ √ √ U √ √ √
575702175 575712175 79 175 2 - √ - - √ √ √ U √ √ √
575702200 575712200 93 200 2 - √ - - √ √ √ U √ √ √
Pendent • K=80 [5.6]
1
⁄ 2” NPT • SIN TY3251 575702286 575712286 141 286 2 - √ - - √ √ √ U √ √ √
575702360 575712360 182 360 2 - √♦ - - √ √ √ U √ √ √
575703135 575713135 57 135 3 √ √ √♦ √ √ √ √ U √ √ √
575703155 575713155 68 155 3 √ √ √♦ √ √ √ √ U √ √ √
575703175 575713175 79 175 3 √ √ √♦ √ √ √ √ U √ √ √
55,6 mm 575703200 575713200 93 200 3 √ √ √♦ √ √ √ √ U √ √ √
(2-3/16") 575703286 575713286 141 286 3 √♦ √ √♦ √♦ √ √ √ U √ √ √
575703360 575713360 182 360 3 √♦ √♦ √♦ √♦ √ √ √ U √ √ √
575704135 575714135 57 135 4 √ √ √♦ √♦ √ √ √ U √ √ √
575704155 575714155 68 155 4 √ √ √♦ √♦ √ √ √ U √ √ √
575704175 575714175 79 175 4 √ √ √♦ √♦ √ √ √ U √ √ √
575704200 575714200 93 200 4 √ √ √♦ √♦ √ √ √ U √ √ √
575704286 575714286 141 286 4 √♦ √ √♦ √♦ √ √ √ U √ √ √
575706135 575716135 57 135 6 √♦ √♦ - - √ √ √ U √ √ √
575706155 575716155 68 155 6 √♦ √♦ - - √ √ √ U √ √ √
575706175 575716175 79 175 6 √♦ √♦ - - √ √ √ U √ √ √
575706200 575716200 93 200 6 √♦ √♦ - - √ √ √ U √ √ √
575706286 575716286 141 286 6 - - - - √ √ √ U √ √ √
575707135 575717135 57 135 7 √♦ √♦ - - √ √ √ U √ √ √
575707155 575717155 68 155 7 √♦ √♦ - - √ √ √ U √ √ √
575707175 575717175 79 175 7 √♦ √♦ - - √ √ √ U √ √ √
575707200 575717200 93 200 7 √♦ √♦ - - √ √ √ U √ √ √
575707286 575717286 141 286 7 √♦ √♦ - - √ √ √ U √ √ √
575707360 575717360 182 360 7 √♦ √♦ - - √ √ √ U √ √ √
575708135 575718135 57 135 8 √♦ √♦ - - √ √ √ U √ √ √
575708155 575718155 68 155 8 √♦ √♦ - - √ √ √ U √ √ √
575708175 575718175 79 175 8 √♦ √♦ - - √ √ √ U √ √ √
575708200 575718200 93 200 8 √♦ √♦ - - √ √ √ U √ √ √
575708286 575718286 141 286 8 - - - - √ √ √ U √ √ √
575709135 575719135 57 135 9 √ √ √♦ √ √ √ √ U √ √ √
Finish Code:
1=Plain Brass, 575709155 575719155 68 155 9 √ √ √♦ √ √ √ √ U √ √ √
2=Poly-Stainless Grey Aluminium 575709175 575719175 79 175 9 √ √ √♦ √ √ √ √ U √ √ √
Polyester RAL9007,
575709200 575719200 93 200 9 √ √ √♦ √ √ √ √ U √ √ √
3=Pure White Polyester RAL9010,
4=Signal White Polyester RAL9003, 575709286 575719286 141 286 9 √♦ √ √♦ √♦ √ √ √ U √ √ √
6=Wax Coated, 575709360 575719360 182 360 9 √♦ √♦ √♦ √♦ √ √ √ U √ √ √
7=Lead Coated,
8=Wax-Over Lead Coated, =Recessed Pendent Not Approved; U Upright Only Approved
9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–3
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Standard Spray Sprinklers


TY-B
Upright, Pendent, & Recessed Pendent (Cont.)

TY-B, K=80 (5.6), 1 ⁄ 2" NPT

K=80 [5.6] • 1⁄ 2” NPT • TFP152


Part No. Temp. Approvals & Listings
Upright • K=80 [5.6]

Belarusian
Ukrainian

Academy
of Russia
1
⁄ 2” NPT • SIN TY315 Finish

LPCB
Upright Pendent

VKF
VdS

Fire
FM
UL

CE
°C °F Code
SIN TY315 SIN TY325

775701135 775711135 57 135 1 √ √ √ √ √ √ √ √ √


50,8 mm 775701155 775711155 68 155 1 √ √ √ √ √ √ √ √ √
(2") 775701175 775711175 79 175 1 √ √ √ √ √ √ √ √ √
775701200 775711200 93 200 1 √ √ √ √ √ √ √ √ √
775701286 775711286 141 286 1 √ √ √ √ √ √ √ √ √
775701360 775711360 182 360 1 √ √ √  √ √ √ √ √
775703135 775713135 57 135 3 √ √ √ √ √ √ √ √ √
775703155 775713155 68 155 3 √ √ √ √ √ √ √ √ √
Pendent • K=80 [5.6] 775703175 775713175 79 175 3 √ √ √ √ √ √ √ √ √
1
⁄ 2” NPT • SIN TY325 775703200 775713200 93 200 3 √ √ √ √ √ √ √ √ √
775703286 775713286 141 286 3 √ √ √ √ √ √ √ √ √
775703360 775713360 182 360 3 √ √ √  √ √ √ √ √
775704135 775714135 57 135 4 √ √ √ √ √ √ √ √ √
775704155 775714155 68 155 4 √ √ √ √ √ √ √ √ √
50,8 mm 775704175 775714175 79 175 4 √ √ √ √ √ √ √ √ √
(2") 775704200 775714200 93 200 4 √ √ √ √ √ √ √ √ √
775704286 775714286 141 286 4 √ √ √ √ √ √ √ √ √
775704360 775714360 182 360 4 √ √ √  √ √ √ √ √
775705135 775715135 57 135 5 √ √ √ √ √ √ √ √ √
775705155 775715155 68 155 5 √ √ √ √ √ √ √ √ √
775705175 775715175 79 175 5 √ √ √ √ √ √ √ √ √
775705200 775715200 93 200 5 √ √ √ √ √ √ √ √ √
775705286 775715286 141 286 5 √ √ √ √ √ √ √ √ √
775705360 775715360 182 360 5 √ √ √  √ √ √ √ √
775709135 775719135 57 135 9 √ √ √ √ √ √ √ √ √
775709155 775719155 68 155 9 √ √ √ √ √ √ √ √ √
775709175 775719175 79 175 9 √ √ √ √ √ √ √ √ √
775709200 775719200 93 200 9 √ √ √ √ √ √ √ √ √
775709286 775719286 141 286 9 √ √ √ √ √ √ √ √ √
775709360 775719360 182 360 9 √ √ √  √ √ √ √ √
=Recessed Pendent Not Approved

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 5=Jet Black Polyester RAL9005, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–4
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Standard Spray Sprinklers
TY-B
Upright, Pendent, & Recessed Pendent (Cont.)

TY-B, K=115 (8.0), 1 ⁄ 2" NPT

K=115 [8.0] • 1⁄ 2” NPT • TFP151


Upright • K=115 [8.0]
1
⁄ 2” NPT • SIN TY4851 Part No. Temperature Approvals & Listings

Ukrainian
Finish
Upright Pendent

LPCB
VdS

FM
°C °F Code

UL

CE
SIN TY4851 SIN TY4951

575601135 575611135 57 135 1 √ √ √ √ √ √


575601155 575611155 68 155 1 √ √ √ √ √ √
55,6 mm 575601175 575611175 79 175 1 √ √ √ √ √ √
(2-3/16")
575601200 575611200 93 200 1 √ √ √ √ √ √
575601286 575611286 141 286 1 √ √ √ √ √ √
575601360 575611360 182 360 1 √ √ √ √ √ √
575603135 575613135 57 135 3 √ √ √ √ √ √
575603155 575613155 68 155 3 √ √ √ √ √ √
Pendent • K=115 [8.0] 575603175 575613175 79 175 3 √ √ √ √ √ √
1
⁄ 2” NPT • SIN TY4951 575603200 575613200 93 200 3 √ √ √ √ √ √
575603286 575613286 141 286 3 √ √ √ √ √ √
575603360 575613360 182 360 3 √ √ √ √ √ √
575604135 575614135 57 135 4 √ √ √ √ √ √
575604155 575614155 68 155 4 √ √ √ √ √ √
575604175 575614175 79 175 4 √ √ √ √ √ √
57,2 mm 575604200 575614200 93 200 4 √ √ √ √ √ √
(2-1/4") 575604286 575614286 141 286 4 √ √ √ √ √ √
575604360 575614360 182 360 4 √ √ √ √ √ √
575605155 575615155 68 155 5 √ √ √ √ √ √
575605200 575615200 93 200 5 √ √ √ √ √ √
575606135 575616135 57 135 6 - - - - √ √
575606155 575616155 68 155 6 - - - - √ √
575606175 575616175 79 175 6 - - - - √ √
575606200 575616200 93 200 6 - - - - √ √
575606286 575616286 141 286 6 - - - - √ √
575607135 575617135 57 135 7 - - - - √ √
575607155 575617155 68 155 7 - - - - √ √
575607175 575617175 79 175 7 - - - - √ √
575607200 575617200 93 200 7 - - - - √ √
575607286 575617286 141 286 7 - - - - √ √
575607360 575617360 182 360 7 - - - - √ √
575608135 575618135 57 135 8 - - - - √ √
575608155 575618155 68 155 8 - - - - √ √
575608175 575618175 79 175 8 - - - - √ √
575608200 575618200 93 200 8 - - - - √ √
575608286 575618286 141 286 8 - - - - √ √
575609135 575619135 57 135 9 √ √ √ √ √ √
575609155 575619155 68 155 9 √ √ √ √ √ √
575609175 575619175 79 175 9 √ √ √ √ √ √
575609200 575619200 93 200 9 √ √ √ √ √ √
575609286 575619286 141 286 9 √ √ √ √ √ √
575609360 575619360 182 360 9 √ √ √ √ √ √

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 5=Jet Black Polyester RAL9005, 6=Wax Coated,
7=Lead Coated, 8=Wax-Over Lead Coated, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–5
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Standard Spray Sprinklers


TY-B
Upright, Pendent, & Recessed Pendent (Cont.)

TY-B, K=115 (8.0), 3 ⁄4" NPT K=115 [8.0] • 3 ⁄4” NPT • TFP151
Part No. Temp. Approvals & Listings

Belarusian
Upright • K=115 [8.0]

Academy
of Russia
Ukrainian
3 Finish
⁄4” NPT • SIN TY4151

LPCB
Upright Pendent

MED
SAS

VKF
VdS

Fire
FM
UL

CE
°C °F Code
SIN TY4151 SIN TY4251

575901135 575911135 57 135 1 √ √ √ √ √ √ √ √ √ √ √


575901155 575911155 68 155 1 √ √ √ √ √ √ √ √ √ √ √
575901175 575911175 79 175 1 √ √ √ √ √ √ √ √ √ √ √
57,2 mm 575901200 575911200 93 200 1 √ √ √ √ √ √ √ √ √ √ √
(2-1/4") 575901286 575911286 141 286 1 √ √ √ √ √ √ √ √ √ √ √
575901360 575911360 182 360 1 √ √ √ √ √ √ √ √ √ √ √
575901000 575911000 Open 1 √ √ √ √ √ √ √ √ √ √ √
575902135 575912135 57 135 2 - √ - - √ √ √ √ √ √ √
575902155 575912155 68 155 2 - √ - - √ √ √ √ √ √ √
575902175 575912175 79 175 2 - √ - - √ √ √ √ √ √ √
575902200 575912200 93 200 2 - √ - - √ √ √ √ √ √ √
Pendent • K=115 [8.0]
3 575902286 575912286 141 286 2 - √ - - √ √ √ √ √ √ √
⁄4” NPT • SIN TY4251
575902360 575912360 182 360 2 - √ - - √ √ √ √ √ √ √
575902000 575912000 Open 2 - √ - - √ √ √ √ √ √ √
575903135 575913135 57 135 3 √ √ √ √ √ √ √ √ √ √ √
575903155 575913155 68 155 3 √ √ √ √ √ √ √ √ √ √ √
575903175 575913175 79 175 3 √ √ √ √ √ √ √ √ √ √ √
575903200 575913200 93 200 3 √ √ √ √ √ √ √ √ √ √ √
58,7 mm 575903286 575913286 141 286 3 √ √ √ √ √ √ √ √ √ √ √
(2-5/16")
575903360 575913360 182 360 3 √ √ √ √ √ √ √ √ √ √ √
575903000 575913000 Open 3 √ √ √ √ √ √ √ √ √ √ √
575904135 575914135 57 135 4 √ √ √ √ √ √ √ √ √ √ √
575904155 575914155 68 155 4 √ √ √ √ √ √ √ √ √ √ √
575904175 575914175 79 175 4 √ √ √ √ √ √ √ √ √ √ √
575904200 575914200 93 200 4 √ √ √ √ √ √ √ √ √ √ √
575904286 575914286 141 286 4 √ √ √ √ √ √ √ √ √ √ √
575904360 575914360 182 360 4 √ √ √ √ √ √ √ √ √ √ √
575904000 575914000 Open 4 √ √ √ √ √ √ √ √ √ √ √
575905155 575915155 68 155 5 √ √  √ √ √ √ √ √ √ √
575905200 575915200 93 200 5 √ √  √ √ √ √ √ √ √ √
575906135 575916135 57 135 6 √ √ - - √ √ √ √ √ √ √
575906155 575916155 68 155 6 √ √ - - √ √ √ √ √ √ √
575906175 575916175 79 175 6 √ √ - - √ √ √ √ √ √ √
575906200 575916200 93 200 6 √ √ - - √ √ √ √ √ √ √
575906286 575916286 141 286 6 √ √ - - √ √ √ √ √ √ √
575907135 575917135 57 135 7 - √ - - √ √ √ √ √ √ √
575907155 575917155 68 155 7 - √ - - √ √ √ √ √ √ √
575907175 575917175 79 175 7 - √ - - √ √ √ √ √ √ √
575907200 575917200 93 200 7 - √ - - √ √ √ √ √ √ √
575907286 575917286 141 286 7 - √ - - √ √ √ √ √ √ √
575907360 575917360 182 360 7 - √ - - √ √ √ √ √ √ √
=Recessed Pendent Not Approved; 575907000 575917000 Open 7 - √ - - √ √ √ √ √ √ √
U Upright Only Approved 575908135 575918135 57 135 8 - √ - - √ √ √ √ √ √ √
575908155 575918155 68 155 8 - √ - - √ √ √ √ √ √ √
Finish Code:
575908175 575918175 79 175 8 - √ - - √ √ √ √ √ √ √
1=Plain Brass, 575908200 575918200 93 200 8 - √ - - √ √ √ √ √ √ √
2=Poly-Stainless Grey Aluminium 575908286 575918286 141 286 8 - √ - - √ √ √ √ √ √ √
Polyester RAL9007,
575909135 575919135 57 135 9 √ √ √ √ √ √ √ √ √ √ √
3=Pure White Polyester RAL9010,
4=Signal White Polyester RAL9003, 575909155 575919155 68 155 9 √ √ √ √ √ √ √ √ √ √ √
5=Jet Black Polyester RAL9005, 575909175 575919175 79 175 9 √ √ √ √ √ √ √ √ √ √ √
6=Wax Coated, 575909200 575919200 93 200 9 √ √ √ √ √ √ √ √ √ √ √
7=Lead Coated, 575909286 575919286 141 286 9 √ √ √ √ √ √ √ √ √ √ √
8=Wax-Over Lead Coated,
575909360 575919360 182 360 9 √ √ √ √ √ √ √ √ √ √ √
9=Chrome Plated
575909000 575919000 Open 9 √ √ √ √ √ √ √ √ √ √ √
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–6
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Standard Spray Sprinklers
TY-B
Horizontal, Recessed Horizontal Sidewall & Vertical Sidewall
K Factor K= 80 (5.6)
1
Thread Size ⁄ 2" NPT

Approvals UL, C-UL, FM, NYC, LPCB

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F), 182°C (360°F), Open (HSW TY3351)

Escutcheon Style 10

Signal White, Pure White, Jet Black, Chrome Plated,


Escutcheon Finish
Natural Brass
Natural Brass, Chrome Plated, Pure White,
Sprinkler Finish Signal White, Jet Black, Poly-Stainless, Lead Coated,
Wax Coated, Wax over Lead Coated
SIN TY3351, TY3451

Wrench Type W-TYPE 6 / W-TYPE 7 (for recessed escutcheons)

Tech Data Sheet TFP161

Light hazard/Ordinary hazard • 5 mm bulb • Small frame • Unique deflector design of the horizontal sidewall sprinkler results in
smaller profile • Designed for installation along a wall or the side of a beam just beneath a smooth ceiling • Water discharge is
directed primarily outward and downward in a quarter spherical pattern • Sidewall sprinklers are often used in lieu of standard
pendent or upright sprinklers due to building construction, economic considerations, or aesthetics • Special deflector on the
vertical sidewall sprinkler allows it to be installed in either a pendent or upright position

Finish Code: 1=Plain Brass, 3=White Polyester RAL9010, 6=Wax Coated, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–7
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Standard Spray Sprinklers


TY-B, K=80 (5.6), 1 ⁄ 2" NPT
K=80 [5.6] • 1 ⁄ 2” NPT • TFP161
Horizontal Sidewall • K=80 [5.6] Part No. Temp. Approvals & Listings
1
⁄ 2” NPT • SIN TY3351

Belarusian

Academy
of Russia
Finish

LPCB
HSW VSW

Fire
FM

UL

CE
°C °F Code
SIN TY3351 SIN TY3451

575781135 575751135 57 135 1 √ √ √ √ √ H


575781155 575751155 68 155 1 √ √ √ √ √ H
55,6 mm 575781175 575751175 79 175 1 √ √ √ √ √ H
(2-3/16") 575781200 575751200 93 200 1 √ √ √ √ √ H
575781286 575751286 141 286 1 √ √ √ √ √ H
575781360 575751360 182 360 1 - H √ √ √ H
575781000 - Open 1 H H H √ √ H
575782135 - 57 135 2 - H - √ √ H
575782155 - 68 155 2 - H - √ √ H
Vertical Sidewall • K=80 [5.6]
1 575782175 - 79 175 2 - H - √ √ H
⁄ 2” NPT • SIN TY3451
575782200 - 93 200 2 - H - √ √ H
575782286 - 141 286 2 - √ - √ √ H
575782360 - 182 360 2 - √ - √ √ H
575782000 - Open 2 - √ - √ √ H
575783135 575753135 57 135 3 √ √ √ √ √ H
55,6 mm 575783155 575753155 68 155 3 √ √ √ √ √ H
(2-3/16") 575783175 575753175 79 175 3 √ √ √ √ H
√
575783200 575753200 93 200 3 √ √ √ √ √ H
575783286 575753286 141 286 3 √ √ √ √ √ H
575783360 575753360 182 360 3 - √ √ √ √ H
575783000 - Open 3 H H H √ √ H
575784135 575754135 57 135 4 √ √ √ √ √ H
575784155 575754155 68 155 4 √ √ √ √ √ H
575784175 575754175 79 175 4 √ √ √ √ √ H
575784200 575754200 93 200 4 √ √ √ √ √ H
575784286 575754286 141 286 4 √ √ √ √ √ H
575784360 575754360 182 360 4 - √ √ √ √ H
575784000 - Open 4 H H H √ √ H
575785155 575755155 68 155 5 √ √ - √ √ H
575785200 575755200 93 200 5 √ √ - √ √ H
575786135 575756135 57 135 6 √ √ - √ √ H
575786155 575756155 68 155 6 √ √ - √ √ H
575786175 575756175 79 175 6 √ √ - √ √ H
575786200 575756200 93 200 6 √ √ - √ √ H
575786286 575756286 141 286 6 √ √ - √ √ H
575787135 575757135 57 135 7 √ √ - √ √ H
575787155 575757155 68 155 7 √ √ - √ √ H
575787175 575757175 79 175 7 √ √ - √ √ H
575787200 575757200 93 200 7 √ √ - √ √ H
575787286 575757286 141 286 7 √ √ - √ √ H
575787360 575757360 182 360 7 - - - √ √ H
575787000 - Open 7 H H - √ √ H
575788135 575758135 57 135 8 √ √ - √ √ H
575788155 575758155 68 155 8 √ √ - √ √ H
575788175 575758175 79 175 8 √ √ - √ √ H
575788200 575758200 93 200 8 √ √ - √ √ H
Finish Code: 575788286 575758286 141 286 8 √ √ - √ √ H
1=Plain Brass,
2=Poly-Stainless Grey Aluminium RAL9007,
575789135 575759135 57 135 9 √ √ √ √ √ H
3=Pure White Polyester RAL9010, 575789155 575759155 68 155 9 √ √ √ √ √ H
4=Signal White Polyester RAL9003, 575789175 575759175 79 175 9 √ √ √ √ √ H
5=Jet Black Polyester RAL9005, 575789200 575759200 93 200 9 √ √ √ √ √ H
6=Wax Coated,
7=Lead Coated,
575789286 575759286 141 286 9 √ √ √ √ √ H
8=Wax-Over Lead Coated, 575789360 575759360 182 360 9 - √ √ √ √ H
9=Chrome Plated 575789000 - Open 9 H H H √ √ H
H=HSW Approved, =Recessed HSW Not Approved; √=Both Approved

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–8
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Standard Spray Sprinklers
TY-FRB
Upright, Pendent, & Recessed Pendent
K Factor K=40 (2.8) • K=60 (4.2) • K=80 (5.6) • K=115 (8.0)
1
Thread Size ⁄ 2" NPT • 3 ⁄ 4" NPT

K=40 – UL, C-UL, FM, NYC


K=60 – UL, C-UL
Approvals
K=80 – UL, C-UL, FM, VdS
K=115 – UL, C-UL, FM, NYC, LPCB, VdS

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F)

K=40, K=60 & K=115 – Style 10 • Style 20 •


Escutcheon Style 30 • Style 40
K=80 – Style 15 • Style 20

Signal White, Pure White, Jet Black, Chrome Plated,


Escutcheon Finish
Natural Brass

Natural Brass, Chrome Plated, Pure White,


Sprinkler Finish
Signal White, Jet Black, Poly-Stainless, Lead Coated

TY313, TY323, TY1131, TY1231, TY2131, TY2231,


SIN
TY3131, TY3231, TY4131, TY4231, TY4831, TY4931

Wrench Type W-TYPE 6 / W-TYPE 7 (for recessed escutcheons)

Tech Data Sheet K=40 thru K=115 – TFP171, K=80 – TFP172

Light hazard/Ordinary hazard • 3 mm bulb • Small frame and narrow profile bulb enhance appearance • Hemispherical water spray
pattern in the area beneath the sprinkler • Designed for use in commercial occupancies such as banks, hotels, and shopping malls.

Finish Code: 1=Plain Brass, 3=White Polyester RAL9010, 9=Chrome Plated


Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–9
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Standard Spray Sprinklers


TY-FRB, K=40 (2.8), 1 ⁄ 2" NPT

K=40 [2.8] • 1 ⁄ 2” NPT • TFP171


Upright • K=40 [2.8] Part No. Temperature Approvals & Listings
1
⁄ 2” NPT • SIN TY1131
Finish
Upright Pendent

FM
°C °F Code

UL
SIN TY1131 SIN TY1231

573301135 573311135 57 [135] 1  √


573301155 573311155 68 [155] 1  √
55,6 mm 573301175 573311175 79 [175] 1  √
(2-3/16") 573301200 573311200 93 [200] 1  √
573301286 573311286 141 [286] 1  √
573303135 573313135 57 [135] 3  √
573303155 573313155 68 [155] 3  √
573303175 573313175 79 [175] 3  √
573303200 573313200 93 [200] 3  √
Pendent • K=40 [2.8] 573303286 573313286 141 [286] 3  √
1
⁄ 2” NPT • SIN TY1231 573304135 573314135 57 [135] 4  √
573304155 573314155 68 [155] 4  √
573304175 573314175 79 [175] 4  √
573304200 573314200 93 [200] 4  √
573304286 573314286 141 [286] 4  √
573305155 573315155 68 [155] 5  √
57,2 mm 573305200 573315200 93 [200] 5  √
(2-1/4") 573309135 573319135 57 [135] 9  √
573309155 573319155 68 [155] 9  √
573309175 573319175 79 [175] 9  √
573309200 573319200 93 [200] 9  √
573309286 573319286 141 [286] 9  √
=Recessed Pendent Not Approved;

TY-FRB, K=60 (4.2), 1 ⁄ 2" NPT

K=60 [4.2] • 1 ⁄ 2” NPT • TFP171


Upright • K=60 [4.2] Part No. Temp. Approvals & Listings
1
⁄ 2” NPT • SIN TY2131
Finish
Upright Pendent
°C °F Code
UL
SIN TY2131 SIN TY2231

573401135 573411135 57 [135] 1 √


573401155 573411155 68 [155] 1 √
55,6 mm 573401175 573411175 79 [175] 1 √
(2-3/16")
573401200 573411200 93 [200] 1 √
573401286 573411286 141 [286] 1 √
573403135 573413135 57 [135] 3 √
573403155 573413155 68 [155] 3 √
573403175 573413175 79 [175] 3 √
573403200 573413200 93 [200] 3 √
Pendent • K=60 [4.2] 573403286 573413286 141 [286] 3 √
1
⁄ 2” NPT • SIN TY2231 573404135 573414135 57 [135] 4 √
573404155 573414155 68 [155] 4 √
573404175 573414175 79 [175] 4 √
573404200 573414200 93 [200] 4 √
573404286 573414286 141 [286] 4 √
55,6 mm 573405155 573415155 68 [155] 5 √
(2-3/16") 573405200 573415200 93 [200] 5 √
573409135 573419135 57 [135] 9 √
573409155 573419155 68 [155] 9 √
573409175 573419175 79 [175] 9 √
573409200 573419200 93 [200] 9 √
573409286 573419286 141 [286] 9 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–10
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Standard Spray Sprinklers

TY-FRB, K=80 (5.6), 1 ⁄ 2" NPT

K=80 [5.6] • 1⁄ 2” NPT • TFP172


Upright • K=80 [5.6] Part No. Temp. Approvals & Listings
1
⁄ 2” NPT • SIN TY313

Belarusian

Academy
of Russia
Ukrainian
Finish
Upright Pendent

LPCB

VKF
Fire
VdS
FM
°C °F Code

UL

CE
SIN TY313 SIN TY323

50,8 mm 773701135 773711135 57 [135] 1 √ √   √ √ √ √ √


(2") 773701155 773711155 68 [155] 1 √ √   √ √ √ √ √
773701175 773711175 79 [175] 1 √ √   √ √ √ √ √
773701200 773711200 93 [200] 1 √ √   √ √ √ √ √
773701286 773711286 141 [286] 1 √ √   √ √ √ √ √
773703135 773713135 57 [135] 3 √ √   √ √ √ √ √
773703155 773713155 68 [155] 3 √ √   √ √ √ √ √
773703175 773713175 79 [175] 3 √ √   √ √ √ √ √
Pendent • K=80 [5.6]
1 773703200 773713200 93 [200] 3 √ √   √ √ √ √ √
⁄ 2” NPT • SIN TY323
773703286 773713286 141 [286] 3 √ √   √ √ √ √ √
773704135 773714135 57 [135] 4 √ √   √ √ √ √ √
773704155 773714155 68 [155] 4 √ √   √ √ √ √ √
773704175 773714175 79 [175] 4 √ √   √ √ √ √ √
50,8 mm
773704200 773714200 93 [200] 4 √ √   √ √ √ √ √
(2")
773704286 773714286 141 [286] 4 √ √   √ √ √ √ √
773705135 773715135 57 [135] 5 √ √   √ √ √ √ √
773705155 773715155 68 [155] 5 √ √   √ √ √ √ √
773705175 773715175 79 [175] 5 √ √   √ √ √ √ √
773705200 773715200 93 [200] 5 √ √   √ √ √ √ √
773705286 773715286 141 [286] 5 √ √   √ √ √ √ √
773709135 773719135 57 [135] 9 √ √   √ √ √ √ √
773709155 773719155 68 [155] 9 √ √   √ √ √ √ √
773709175 773719175 79 [175] 9 √ √   √ √ √ √ √
773709200 773719200 93 [200] 9 √ √   √ √ √ √ √
773709286 773719286 141 [286] 9 √ √   √ √ √ √ √
√=Both Approved, =Recessed Pendent Not Approved;

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 5=Jet Black Polyester RAL9005, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–11
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Standard Spray Sprinklers

TY-FRB, K=80 (5.6), 1 ⁄ 2" NPT

K=80 [5.6] • 1 ⁄ 2” NPT • TFP171


Upright • K=80 [5.6] Part No. Temp. Approvals & Listings
1
⁄ 2” NPT • SIN TY3131

Belarusian

Academy
of Russia
Ukrainian
Finish
Upright Pendent

LPCB

MED

VKF
Fire
SAS
VdS
FM
°C °F Code

UL

CE
SIN TY3131 SIN TY3231

573701135 573711135 57 [135] 1 √b √  √ √ √ √ √ P √ √


55,6 mm 573701155 573711155 68 [155] 1 √b √  √ √ √ √ √ P √ √
(2-3/16") 573701175 573711175 79 [175] 1 √b √  √ √ √ √ √ P √ √
573701200 573711200 93 [200] 1 √b √  √ √ √ √ √ P √ √
573701286 573711286 141 [286] 1 √b √  √ √ √ √ √ P √ √
573702135 573712135 57 [135] 2 - √a - - √ √ √ √ P √ √
573702155 573712155 68 [155] 2 - √a - - √ √ √ √ P √ √
573702175 573712175 79 [175] 2 - √a - - √ √ √ √ P √ √
Pendent • K=80 [5.6] 573702200 573712200 93 [200] 2 - √a - - √ √ √ √ P √ √
1
⁄ 2” NPT • SIN TY3231 573702286 573712286 141 [286] 2 - √a - - √ √ √ √ P √ √
573703135 573713135 57 [135] 3 √b √  √ √ √ √ √ P √ √
573703155 573713155 68 [155] 3 √b √  √ √ √ √ √ P √ √
573703175 573713175 79 [175] 3 √b √  √ √ √ √ √ P √ √
573703200 573713200 93 [200] 3 √b √  √ √ √ √ √ P √ √
573703286 573713286 141 [286] 3 √b √  √ √ √ √ √ P √ √
55,6 mm
(2-3/16") 573704135 573714135 57 [135] 4 √b √  √ √ √ √ √ P √ √
573704155 573714155 68 [155] 4 √b √  √ √ √ √ √ P √ √
573704175 573714175 79 [175] 4 √b √  √ √ √ √ √ P √ √
573704200 573714200 93 [200] 4 √b √  √ √ √ √ √ P √ √
573704286 573714286 141 [286] 4 √b √  √ √ √ √ √ P √ √
573707135 573717135 57 [135] 7   - - √ √ √ √ P √ √
573707155 573717155 68 [155] 7   - - √ √ √ √ P √ √
573707175 573717175 79 [175] 7   - - √ √ √ √ P √ √
573707200 573717200 93 [200] 7   - - √ √ √ √ P √ √
573707286 573717286 141 [286] 7   - - √ √ √ √ P √ √
573709135 573719135 57 [135] 9 √b √  √ √ √ √ √ P √ √
573709155 573719155 68 [155] 9 √b √  √ √ √ √ √ P √ √
573709175 573719175 79 [175] 9 √b √  √ √ √ √ √ P √ √
573709200 573719200 93 [200] 9 √b √  √ √ √ √ √ P √ √
573709286 573719286 141 [286] 9 √b √  √ √ √ √ √ P √ √
P=Pendent Approved, √=Both Approved, =Recessed Pendent Not Approved;
a. Recessed Pendent Installed with Style 10 (1 ⁄ 2 in. NPT) or Style 40 (3 ⁄4 in. NPT) 3 ⁄4 in. Total
Adjustment Recessed Escutcheon, as applicable.
b. Recessed Pendent Installed with Style 20 (1 ⁄ 2 in. NPT) or Style 30 (3 ⁄4 in. NPT) 1 ⁄ 2 in. Total
Adjustment Recessed Escutcheon, as applicable.

Finish Code: 1=Plain Brass, 2=Poly-Stainless Grey Aluminium Polyester RAL9007, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003,
7=Lead Coated, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–12
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Standard Spray Sprinklers

TY-FRB, K=115 (8.0), 1 ⁄ 2" NPT

K=115 [8.0] • 1 ⁄ 2” NPT • TFP171


Upright • K=115 [8.0] Part No. Temp. Approvals & Listings
1
⁄ 2” NPT • SIN TY4831
Finish
Upright Pendent

LPCB
VdS
°C °F Code

UL

CE
SIN TY4831 SIN TY4931

573601135 573611135 57 [135] 1 √ √ √ √


573601155 573611155 68 [155] 1 √ √ √ √
55,6 mm 573601175 573611175 79 [175] 1 √ √ √ √
(2-3/16") 573601200 573611200 93 [200] 1 √ √ √ √
573601286 573611286 141 [286] 1 √ √ √ √
573603135 573613135 57 [135] 3 √ √ √ √
573603155 573613155 68 [155] 3 √ √ √ √
573603175 573613175 79 [175] 3 √ √ √ √
573603200 573613200 93 [200] 3 √ √ √ √
Pendent • K=115 [8.0] 573603286 573613286 141 [286] 3 √ √ √ √
1
⁄ 2” NPT • SIN TY4931 573604135 573614135 57 [135] 4 √ √ √ √
573604155 573614155 68 [155] 4 √ √ √ √
573604175 573614175 79 [175] 4 √ √ √ √
573604200 573614200 93 [200] 4 √ √ √ √
573604286 573614286 141 [286] 4 √ √ √ √
573605155 573615155 68 [155] 5 √ √ √ √
57,2 mm
573605200 573615200 93 [200] 5 √ √ √ √
(2-1/4")
573607135 573617135 57 [135] 7 √ - - √
573607155 573617155 68 [155] 7 √ - - √
573607175 573617175 79 [175] 7 √ - - √
573607200 573617200 93 [200] 7 √ - - √
573607286 573617286 141 [286] 7 √ - - √
573609135 573619135 57 [135] 9 √ √ √ √
573609155 573619155 68 [155] 9 √ √ √ √
573609175 573619175 79 [175] 9 √ √ √ √
573609200 573619200 93 [200] 9 √ √ √ √
573609286 573619286 141 [286] 9 √ √ √ √

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 5=Jet Black Polyester RAL9005,
7=Lead Coated, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–13
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Standard Spray Sprinklers


TY-FRB, K=115 (8.0), 3 ⁄4" NPT

K=115 [8.0] • 3 ⁄4” NPT • TFP171


Upright • K=115 [8.0]
3 Part No. Temp. Approvals & Listings
⁄4” NPT • SIN TY4131

Belarusian

Academy
of Russia
Ukrainian
Finish
Upright Pendent

LPCB

MED

VKF
Fire
SAS
VdS
FM
°C °F Code

UL

CE
SIN TY4131 SIN TY4231

573901135 573911135 57 [135] 1 √b √   √ √ √ √ √ √ √


57,2 mm 573901155 573911155 68 [155] 1 √b √   √ √ √ √ √ √ √
(2-1/4") 573901175 573911175 79 [175] 1 √b √   √ √ √ √ √ √ √
573901200 573911200 93 [200] 1 √b √   √ √ √ √ √ √ √
573901286 573911286 141 [286] 1 √b √   √ √ √ √ √ √ √
573902135 573912135 57 [135] 2 - √a - - √ √ √ √ √ √ √
573902155 573912155 68 [155] 2 - √a - - √ √ √ √ √ √ √
573902175 573912175 79 [175] 2 - √a - - √ √ √ √ √ √ √
Pendent • K=115 [8.0] 573902200 573912200 93 [200] 2 - √a - - √ √ √ √ √ √ √
3
⁄4” NPT • SIN TY4231 573902286 573912286 141 [286] 2 - √a - - √ √ √ √ √ √ √
573903135 573913135 57 [135] 3 √b √   √ √ √ √ √ √ √
573903155 573913155 68 [155] 3 √b √   √ √ √ √ √ √ √
573903175 573913175 79 [175] 3 √b √   √ √ √ √ √ √ √
573903200 573913200 93 [200] 3 √b √   √ √ √ √ √ √ √
54,0 mm 573903286 573913286 141 [286] 3 √b √   √ √ √ √ √ √ √
(2-1/8") 573904135 573914135 57 [135] 4 √b √   √ √ √ √ √ √ √
573904155 573914155 68 [155] 4 √b √   √ √ √ √ √ √ √
573904175 573914175 79 [175] 4 √b √   √ √ √ √ √ √ √
573904200 573914200 93 [200] 4 √b √   √ √ √ √ √ √ √
573904286 573914286 141 [286] 4 √b √   √ √ √ √ √ √ √
573905155 573915155 68 [155] 5 √b √   √ √ √ √ √ √ √
573905200 573915200 93 [200] 5 √b √   √ √ √ √ √ √ √
573907135 573917135 57 [135] 7 -  - - √ √ √ √ √ √ √
573907155 573917155 68 [155] 7 -  - - √ √ √ √ √ √ √
573907175 573917175 79 [175] 7 -  - - √ √ √ √ √ √ √
573907200 573917200 93 [200] 7 -  - - √ √ √ √ √ √ √
573907286 573917286 141 [286] 7 -  - - √ √ √ √ √ √ √
573909135 573919135 57 [135] 9 √b √   √ √ √ √ √ √ √
573909155 573919155 68 [155] 9 √b √   √ √ √ √ √ √ √
573909175 573919175 79 [175] 9 √b √   √ √ √ √ √ √ √
573909200 573919200 93 [200] 9 √b √   √ √ √ √ √ √ √
573909286 573919286 141 [286] 9 √b √   √ √ √ √ √ √ √
√=Both Approved, =Recessed Pendent Not Approved;
a. Recessed Pendent Installed with Style 10 (1 ⁄ 2 in. NPT) or Style 40 (3 ⁄4 in. NPT) 3 ⁄4 in. Total
Adjustment Recessed Escutcheon, as applicable.
b. Recessed Pendent Installed with Style 20 (1 ⁄ 2 in. NPT) or Style 30 (3 ⁄4 in. NPT) 1 ⁄ 2 in. Total
Adjustment Recessed Escutcheon, as applicable.

Finish Code: 1=Plain Brass, 2=Poly-Stainless Grey Aluminium Polyester RAL9007, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003,
5=Jet Black Polyester RAL9005, 7=Lead Coated, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–14
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Standard Spray Sprinklers
TY-FRB
Horizontal, Recessed Horizontal Sidewall & Vertical Sidewall
K Factor K= 80 (5.6)
1
Thread Size ⁄ 2" NPT

Approvals UL, C-UL, FM, NYC, LPCB

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F)

Escutcheon Style 10 • Style 20

Signal White, Pure White, Jet Black, Chrome Plated,


Escutcheon Finish
Brass Plated

Natural Brass, Chrome Plated, Pure White,


Sprinkler Finish
Signal White, Jet Black, Poly-Stainless, Lead Coated

SIN TY3331, TY3431

Wrench Type W-TYPE 6 / W-TYPE 7 (for recessed escutcheons)

Tech Data Sheet TFP176

Light hazard/Ordinary hazard • 3 mm bulb • Designed for use in applications where aesthetics must be considered or where building
construction makes the installation of standard pendent or upright sprinklers impractical • Vertical sidewall sprinkler can be
installed in either the pendent or upright position along a wall or the side of a beam and just below a smooth ceiling

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–15
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Standard Spray Sprinklers


TY-FRB, K=80 (5.6), 1 ⁄ 2" NPT

K=80 [5.6] • 1 ⁄ 2” NPT • TFP176


Horizontal Sidewall • K=80 [5.6]
1
⁄ 2” NPT • SIN TY3331 Part No. Temp. Approvals & Listings

Academy
of Russia
Finish

LPCB
HSW VSW

VKF
Fire
FM

UL

CE
°C °F Code
SIN TY3331 SIN TY3431

573781135 573751135 57 135 1 √b √ √ √ H √


573781155 573751155 68 155 1 √b √ √ √ H √
573781175 573751175 79 175 1 √b √ √ √ H √
55,6 mm 573781200 573751200 93 200 1 √b √ √ √ H √
(2-3/16") 573781286 573751286 141 286 1  √ √ √ H √
573782135 - 57 135 2 - √a - √ H √
573782155 - 68 155 2 - √a - √ H √
573782175 - 79 175 2 - √a - √ H √
Vertical Sidewall • K=80 [5.6] 573782200 - 93 200 2 - √a - √ H √
1
⁄ 2” NPT • SIN TY3431 573782286 - 141 286 2 - √a - √ H √
573783135 573753135 57 135 3 √b √ √ √ H √
573783155 573753155 68 155 3 √b √ √ √ H √
573783175 573753175 79 175 3 √b √ √ √ H √
573783200 573753200 93 200 3 √b √ √ √ H √
573783286 573753286 141 286 3  √ √ √ H √
55,6 mm 573784135 573754135 57 135 4 √b √ √ √ H √
(2-3/16")
573784155 573754155 68 155 4 √b √ √ √ H √
573784175 573754175 79 175 4 √b √ √ √ H √
573784200 573754200 93 200 4 √b √ √ √ H √
573784286 573754286 141 286 4  √ √ √ H √
573785155 573755155 68 155 5 √b √ √ √ H √
573785200 573755200 93 200 5 √b √ √ √ H √
573787135 573757135 57 135 7   - √ H √
573787155 573757155 68 155 7   - √ H √
573787175 573757175 79 175 7   - √ H √
573787200 573757200 93 200 7   - √ H √
573787286 573757286 141 286 7   - √ H √
573789135 573759135 57 135 9 √b √ √ √ H √
573789155 573759155 68 155 9 √b √ √ √ H √
573789175 573759175 79 175 9 √b √ √ √ H √
573789200 573759200 93 200 9 √b √ √ √ H √
573789286 573759286 141 286 9  √ √ √ H √
H=HSW Approved, √=Both Approved =Recessed HSW Not Approved;
a. Recessed HSW Installed with Style 10 (1 ⁄ 2 in. NPT) or Style 40 (3 ⁄4 in. NPT) 3 ⁄4 in. Total
Adjustment Recessed Escutcheon, as applicable.
b. Recessed HSW Installed with Style 20 (1 ⁄ 2 in. NPT) or Style 30 (3 ⁄4 in. NPT) 1 ⁄ 2 in. Total
Adjustment Recessed Escutcheon, as applicable.

Finish Code: 1=Plain Brass, 2=Poly-Stainless Grey Aluminium Polyester RAL9007, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003,
5=Jet Black Polyester RAL9005, 7=Lead Coated, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–16
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Standard Spray Sprinklers
RFII
Concealed Pendent
K Factor K=80 (5.6)
1
Thread Size ⁄2" NPT

3mm= UL, C-UL, NYC, VdS


Approvals 3mm Standard Response is also FM, LPCB
5mm= UL, C-UL, FM, NYC, LPCB

68°C (155°F) - Sprinkler, 59°C (139°F) - Cover Plate


Temperature
93°C (200°F) - Sprinkler, 74°C (165°F) - Cover Plate

Chrome, Brushed Chrome, Brass, Signal White,


Cover Plate Finish
Grey White, Pure White, Jet Black, Custom

SIN TY3551, TY3531

Wrench Type RFII

Tech Data Sheet TFP181

Light hazard/Ordinary hazard • 5 mm bulb (standard) 3 mm bulb (quick) • Internally threaded closure with 12,7 mm (1 ⁄ 2") of
adjustment • Concealed in an enclosed escutcheon plate with flat cover for use in those applications where aesthetics is a primary
consideration • Separable, two-piece design of the mounting cup and cover plate allows installation of the sprinklers and pressure
testing of the fire protection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling
• Available with optional dust and air seal

K=80 [5.6] • 1 ⁄ 2” NPT or ISO • TFP181


RFII, K=80 (5.6), 1 ⁄ 2" NPT or ISO Part No. * Temp. Approvals & Listings

Belarusian

Academy
of Russia
Ukrainian
Concealed Pendent • K=80 [5.6] Finish

LPCB
RFII SR RFII QR

VdS

Fire
FM
UL

CE
1
⁄ 2” NPT • SIN SR: TY3551, QR: TY3531 (Shown) °C °F Code
SIN TY3551 SIN TY3531

517901155 517921155 68 [155] 1 √ √ Q √ √ √ S √


517901200 517921200 93 [200] 1 √ √ Q √ √ √ S √
* Use Suffix “I” for ISO 7-1 connection; for example, 517921155-I
Q: Quick Response, S: Standard Response, √=Both Approved
44,5 to 57,2 mm
Cover Plate
(1-3/4" to 2-1/4")
Part No. Temp. For use with
Cover Plate
Cover Sprinkler Finish
°C °F
Plate Temp.
567921135 59 139 68°C, 155°F Brass
4,8 to 17,5 mm 567921165 74 165 93°C, 200°F Brass
(3/16" to 11/16") 567920135 59 139 68°C, 155°F Grey White (RAL9002)
567920165 74 165 93°C, 200°F Grey White (RAL9002)
567923135 59 139 68°C, 155°F Pure White (RAL9010)
567923165 74 165 93°C, 200°F Pure White (RAL9010)
567924135 59 139 68°C, 155°F Signal White (RAL9003)
Clean Room Seal 567924165 74 165 93°C, 200°F Signal White (RAL9003)
567926135 59 139 68°C, 155°F Jet Black (RAL9005)
597926165 74 165 93°C, 200°F Jet Black (RAL9005)
567928135 59 139 68°C, 155°F Brushed Chrome
567928165 74 165 93°C, 200°F Brushed Chrome
567929135 59 139 68°C, 155°F Chrome
44,5 to 57,2 mm 567929165 74 165 93°C, 200°F Chrome
(1-3/4" to 2-1/4") 56792X135 59 139 68°C, 155°F Custom
56792X165 74 165 93°C, 200°F Custom

Clean Room Seal


Approvals & Listings
4,8 to 17,5 mm Part No.
UL

(3/16" to 11/16")

569081001 √
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–17
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Standard Spray Sprinklers


RFII-MRI
Concealed Pendent
K Factor K=80 (5.6)
1
Thread Size ⁄2" NPT

3mm= UL, C-UL


Approvals
5mm= UL, C-UL

68°C (155°F) - Sprinkler, 59°C (139°F) - Cover Plate


Temperature
93°C (200°F) - Sprinkler, 74°C (165°F) - Cover Plate

Brass, Signal White, Grey White, Pure White,


Cover Plate Finish
Jet Black, Custom

SIN TY3550, TY3530

Wrench Type RFII

Tech Data Sheet TFP182

Non-magnetic flat-plate concealed sprinkler for MRI room applications • Tested up to 7 Tesla (standard MRI apparatus is typically
3 Tesla) • Concealed in an enclosed escutcheon plate with flat cover • Separable, two-piece design of the mounting cup and cover
allows installation of the sprinklers and pressure testing of the fire protection system prior to installation of a suspended ceiling or
application of the finish coating to a fixed ceiling • Internally threaded closure with 12,7 mm (1 ⁄ 2") of adjustment

RFII-MRI, K=80 (5.6), 1 ⁄ 2" NPT


K=80 [5.6] • 1 ⁄ 2” NPT • TFP182
Approvals &
Concealed Pendent • K=80 [5.6] Part No. * Temp.
1 Listings
⁄ 2” NPT • SIN SR: TY3550, QR: TY3530 (Shown)
Finish
RFII-MRI RFII-MRI
Code
SR QR

UL
°C °F
SIN TY3550 SIN TY3530

518011155 518001155 68 [155] 1 √


518011200 518001200 93 [200] 1 √
44,5 to 57,2 mm
(1-3/4" to 2-1/4") Cover Plate
Part No. Temp. For use with
Cover Plate
Cover Sprinkler Finish
°C °F
Plate Temp.
567941135 59 139 68°C, 155°F Brass
4,8 to 17,5 mm 567941165 74 165 93°C, 200°F Brass
(3/16" to 11/16") 567940135 59 139 68°C, 155°F Grey White (RAL9002)
567940165 74 165 93°C, 200°F Grey White (RAL9002)
567944135 59 139 68°C, 155°F Signal White (RAL9003)
567944165 74 165 93°C, 200°F Signal White (RAL9003)
567946135 59 139 68°C, 155°F Jet Black (RAL9005)
Clean Room Seal 597946165 74 165 93°C, 200°F Jet Black (RAL9005)
56794X135 59 139 68°C, 155°F Custom
56794X165 74 165 93°C, 200°F Custom

Clean Room Seal


Approvals & Listings
44,5 to 57,2 mm Part No.
UL

(1-3/4" to 2-1/4")

569081001 √

4,8 to 17,5 mm
(3/16" to 11/16")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–18
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Standard Spray Sprinklers
TY-L
Upright, Pendent, & Recessed Pendent
K Factor K= 80 (5.6) • K=115 (8.0)
1
Thread Size ⁄2" NPT • 3 ⁄ 4" NPT

Approvals UL, C-UL, FM, LPCB

Temperature 74°C (165°F), 100°C (212°F), 138°C (280°F)

Escutcheon Style 20 • Style 30

Escutcheon Finish Signal White, Chrome Plated, Brass Plated

Natural Brass, Chrome Plated, Lead Coated,


Sprinkler Finish
Wax over Lead Coated, Wax Coated

SIN TY3111, TY3211, TY4111 TY4211, TY4811, TY4911

Wrench Type W-TYPE 9 / W-TYPE 10 (for recessed escutcheons)

Tech Data Sheet TFP110

All hazard • Solder type • Discharges a hemispherical water spray pattern in the area beneath the sprinkler • Designed for use in
light, ordinary, and extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, chemical
plants, etc.

TY-L, K=80 (5.6), 1 ⁄ 2" NPT

K=80 [5.6] • 1 ⁄ 2” NPT • TFP110


Upright • K=80 [5.6] Part No. Temperature Approvals & Listings
1
⁄ 2” NPT • SIN TY3111 Finish
Upright Pendent

LPCB
FM
°C °F Code

UL

CE
SIN TY3111 SIN TY3211

531111165 531121165 74 [165] 1 √ √ √ U


531111212 531121212 100 [212] 1 √ √ √ U
531111280 531121280 138 [280] 1 √ √ √ U
66,7 mm
531116165 531126165 74 [165] 6   - U
(2-5/8")
531116212 531126212 100 [212] 6   - U
531116280 531126280 138 [280] 6  - - U
531117165 531127165 74 [165] 7   - U
531117212 531127212 100 [212] 7   - U
531117280 531127280 138 [280] 7 -  - U
531118165 531128165 74 [165] 8   - U
531118212 531128212 100 [212] 8   - U
Pendent • K=80 [5.6] 531119165 531129165 74 [165] 9 √ √ √ U
1
⁄ 2” NPT • SIN TY3211 531119212 531129212 100 [212] 9 √ √ √ U
531119280 531129280 138 [280] 9 √ √ √ U
U=Upright Approved, √=Both Approved, =Recessed Pendent Not Approved

66,7 mm
(2-5/8")

Finish Code: 1=Plain Brass, 6=Wax Coated, 7=Lead Coated, 8=Wax-Over Lead Coated, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–19
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Standard Spray Sprinklers

TY-L, K=115 (8.0), 1 ⁄ 2" NPT


Upright • K=115 [8.0] K=115 [8.0] • 1 ⁄ 2” NPT • TFP110
1
⁄ 2” NPT • SIN TY4811 Part No. Temperature Approvals & Listings
Finish
Upright Pendent

LPCB
FM
°C °F Code

UL
SIN TY4811 SIN TY4911

531061165 531071165 74 [165] 1  √ 


66,7 mm 531061212 531071212 100 [212] 1  √ 
(2-5/8") 531061280 531071280 138 [280] 1 √ √ √
531066165 531076165 74 [165] 6   -
531066212 531076212 100 [212] 6   -
531067165 531077165 74 [165] 7   -
531067212 531077212 100 [212] 7   -
531067280 531077280 138 [280] 7 - √ -
531068165 531078165 74 [165] 8   -
Pendent • K=115 [8.0]
1
⁄ 2” NPT • SIN TY4911 531068212 531078212 100 [212] 8   -
531069165 531079165 74 [165] 9  √ 
531069212 531079212 100 [212] 9  √ 
531069280 531079280 138 [280] 9 √ √ √
√=Both Approved, =Recessed Pendent Not Approved;

66,7 mm
(2-5/8")

TY-L, K=115 (8.0), 3 ⁄4" NPT


Upright • K=115 [8.0] K=115 [8.0] • 3 ⁄4” NPT • TFP110
3
⁄4” NPT • SIN TY4111 Part No. Temperature Approvals & Listings
Finish
Upright Pendent LPCB
FM

°C °F Code
UL

SIN TY4111 SIN TY4211

531011165 531021165 74 [165] 1  √ U


68,3 mm 531011212 531021212 100 [212] 1  √ U
(2-11/16") 531011280 531021280 138 [280] 1 √ √ U
531016165 531026165 74 [165] 6   -
531016212 531026212 100 [212] 6   -
531016280 531026280 138 [280] 6  - -
531017165 531027165 74 [165] 7   -
531017212 531027212 100 [212] 7   -
531017280 531027280 138 [280] 7 - √ -
531018165 531028165 74 [165] 8   -
Pendent • K=115 [8.0]
3
⁄4” NPT • SIN TY4211 531018212 531028212 100 [212] 8   -
531019165 531029165 74 [165] 9  √ U
531019212 531029212 100 [212] 9  √ U
531019280 531029280 138 [280] 9 √ √ U
U=Upright Approved, √=Both Approved, =Recessed Pendent Not Approved

68,3 mm
(2-11/16")

Finish Code: 1=Plain Brass, 6=Wax Coated, 7=Lead Coated, 8=Wax-Over Lead Coated, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–20
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Standard Spray Sprinklers
TY-L
Horizontal Sidewall
K Factor K= 80 (5.6)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, FM

Temperature 74°C (165°F), 100°C (212°F), 138°C (280°F)

Natural Brass, Chrome Plated, Lead Coated, Wax


Sprinkler Finish
Coated, Wax over Lead Coated

SIN TY3311

Wrench Type W-TYPE 9

Tech Data Sheet TFP120

Light hazard / Ordinary hazard • Solder type • Suited for hotels, nursing homes and hospitals • Design allows piping to be confined
to corridors, closets or service areas • They are designed for installation along a wall or the side of a beam and just beneath a
smooth ceiling.

TY-L, K=80 (5.6), 1 ⁄ 2" NPT


K=80 [5.6] • 1 ⁄ 2” NPT • TFP120
Part No. Temperature Approvals & Listings
Horizontal Sidewall • K=80 [5.6]
1
⁄ 2” NPT • SIN TY3311 Finish
HSW

FM
°C °F Code

UL
SIN TY3311

531131165 74 [165] 1 √ √
TOP

531131212 100 [212] 1 √ √


531131280 138 [280] 1 √ √
531136165 74 [165] 6 - √
531136212 100 [212] 6 - √
73,0 mm 531137165 74 [165] 7 - √
(2-7/8") 531137212 100 [212] 7 - √
531137280 138 [280] 7 - -
531138165 74 [165] 8 - √
531138212 100 [212] 8 - √
531139165 74 [165] 9 √ √
531139212 100 [212] 9 √ √
531139280 138 [280] 9 √ √

Finish Code: 1=Plain Brass, 6=Wax Coated, 7=Lead Coated, 8=Wax-Over Lead Coated, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–21
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Standard Spray Sprinklers


TY-FRL
Upright, Pendent, & Recessed Pendent
K Factor K= 40 (2.8) • K= 80 (5.6) • K= 115 (8.0)
1
Thread Size ⁄2" NPT • 3 ⁄ 4" NPT

40 =UL, C-UL, NYC


Approvals 80 =UL, C-UL, FM, NYC, LPCB
115 = UL, C-UL, FM, NYC

Temperature 74°C (165°F), 100°C (212°F)


1
⁄2" NPT - Style 20
Escutcheon 3
⁄4" NPT - Style 30

Escutcheon Finish White Coated, Chrome Plated, Brass Plated

Sprinkler Finish Natural Brass, Painted White

SIN TY1121, TY1221, TY3121 TY3221, TY4121, TY4221

Wrench Type W-TYPE 9 / W-TYPE 12 (for recessed escutcheons)

Tech Data Sheet TFP130

Light hazard/Ordinary hazard - light hazard K= 40 (2.8) • Solder type • Typically used in hotels, motels, office buildings, and other
commercial and industrial applications

TY-FRL, K=40 (2.8), 1 ⁄ 2" NPT


K=40 [2.8] • 1 ⁄ 2” NPT • TFP130
Approvals &
Upright • K=40 [2.8] Part No. Temperature
1 Listings
⁄ 2” NPT • SIN TY1121
Finish
Upright Pendent Code
°C °F

UL
SIN TY1121 SIN TY1221

589731165 589711165 74 [165] 1 √


589731212 589711212 100 [212] 1 √
68,3 mm 589739165 589719165 74 [165] 9 √
(2-11/16") 589739212 589719212 100 [212] 9 √

Pendent • K=40 [2.8]


1
⁄ 2” NPT • SIN TY1221

68,3 mm
(2-11/16")

Finish Code: 1=Plain Brass, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–22
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Standard Spray Sprinklers
TY-FRL, K=80 (5.6), 1 ⁄ 2" NPT
Upright • K=80 [5.6] K=80 [5.6] • 1 ⁄ 2” NPT • TFP130
1
⁄ 2” NPT • SIN TY3121 Part No. Temperature Approvals & Listings
Finish

LPCB *
Upright Pendent

FM
°C °F Code

UL

CE
SIN TY3121 SIN TY3221

589741165 589821165 74 [165] 1  √ √ √


589741212 589821212 100 [212] 1  √ √ √
68,3 mm 589749165 589829165 74 [165] 9  √ √ √
(2-11/16") 589749212 589829212 100 [212] 9  √ √ √
* LPCB Approved with Unpainted Frame
=Recessed Pendent Not Approved

Pendent • K=80 [5.6]


1
⁄ 2” NPT • SIN TY3221

68,3 mm
(2-11/16")

TY-FRL, K=115 (8.0), 3 ⁄4" NPT


Upright • K=115 [8.0] K=115 [8.0] • 3 ⁄4” NPT • TFP130
3
⁄4” NPT • SIN TY4121 Part No. Temperature Approvals & Listings
Finish
Upright Pendent
FM
°C °F Code

UL
SIN TY4121 SIN TY4221

581741165 581721165 74 [165] 1 √ √


581741212 581721212 100 [212] 1 √ √
71,4 mm 581749165 581729165 74 [165] 9 √ √
(2-13/16") 581749212 581729212 100 [212] 9 √ √

Pendent • K=115 [8.0]


3
⁄4” NPT • SIN TY4221

74,6 mm
(2-15/16")

Finish Code: 1=Plain Brass, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–23
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Standard Spray Sprinklers


TY-FRL

Horizontal Sidewall
K Factor K= 80 (5.6)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, FM, NYC

Temperature 74°C (165°F), 100°C (212°F)

Sprinkler Finish Natural Brass, Chrome Plated

SIN TY3321

Wrench Type W-TYPE 9

Tech Data Sheet TFP140

Light hazard/Ordinary hazard • Solder type • Designed for compact installation along a wall or on the side of a beam just beneath a
smooth ceiling • Generally used in lieu of pendent or upright sprinklers because of aesthetics, building construction, where piping
across the ceiling is not desirable.

TY-FRL, K=80 (5.6), 1 ⁄ 2" NPT


Horizontal Sidewall • K=80 [5.6] K=80 [5.6] • 1 ⁄ 2” NPT • TFP140
1
⁄ 2” NPT • SIN TY3321 Part No. Temperature Approvals & Listings
Finish
HSW

FM
°C °F Code

UL
SIN TY3321
TOP

589461165 74 [165] 1 √ √
589461212 100 [212] 1 √ √
589469165 74 [165] 9 √ √
589469212 100 [212] 9 √ √
84,2 mm
(3-5/16")

Finish Code: 1=Plain Brass, 9=Chrome Plated


Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–24
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Standard Spray Sprinklers
RFII-HSW
Concealed Horizontal Sidewall
K Factor K= 80 (5.6)

Thread Size 1⁄2" NPT

Approvals UL, C-UL

71°C (160°F) - Sprinkler, 59°C (139°F) - Cover Plate


Temperature
100°C (212°F) - Sprinkler, 74°C (165°F) - Cover Plate

Ivory, Beige, Pure White, Signal White, Grey White,


Cover Plate Finish Brown, Black, Brushed Chrome, Brushed Brass,
Custom Paint

SIN TY3521

Wrench Type W-TYPE 37

Tech Data Sheet TFP185

Light hazard/Ordinary hazard • Solder Type • Internally threaded closure with 12,7 mm (1 ⁄ 2") of adjustment • Concealed in an
enclosed escutcheon plate with flat cover for use in those applications where aesthetics is a primary consideration • Separable,
two-piece design of the mounting cup and cover plate allows installation of the sprinklers and pressure testing of the fire protection
system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling • Available with optional dust
and air seal

K=80 [5.6] • 1 ⁄ 2” NPT • TFP185


RFII, K=80 (5.6), 1 ⁄ 2" NPT Part No. Temp. Approvals & Listings

Concealed HSW • K=80 [5.6] Finish


RFI-HSW

C-UL
UL
1
⁄ 2” NPT • SIN: TY3521 °C °F Code
SIN TY3521

4,8 mm 505501165 71 [160] 1 √ √


Cover Plate
(3/16") 505501212 100 [212] 1 √ √
Assembly
6,4 mm (1/4")
Adjustment
Cover Plate
Part No. Temp. For use with
Cover Plate
Cover Sprinkler Finish
°C °F
Plate Temp.
562040135 59 139 71°C, 160°F
Ivory (RAL1015)
81,0 mm 562040165 74 165 100°C, 212°F
(3-3/16" Dia.) 562042135 59 139 71°C, 160°F
Beige (RAL1001)
562042165 74 165 100°C, 212°F
562043135 59 139 71°C, 160°F
Pure White (RAL9010)
562043165 74 165 100°C, 212°F
562044135 59 139 71°C, 160°F
Signal White (RAL9003)
562044165 74 165 100°C, 212°F
562045135 59 139 71°C, 160°F
Grey White (RAL9002)
562045165 74 165 100°C, 212°F
562046135 59 139 71°C, 160°F
Brown (RAL8028)
562046165 74 165 100°C, 212°F
562047135 59 139 71°C, 160°F
39,7 mm ± 3,2 mm Black (RAL9005)
562047165 74 165 100°C, 212°F
(1-9/16" ± 1/8")
562048135 59 139 71°C, 160°F
Brushed Brass
562048165 74 165 100°C, 212°F
562049135 59 139 71°C, 160°F
Brushed Chrome
562049165 74 165 100°C, 212°F
56204X135 59 139 71°C, 160°F
Custom Paint
56204X165 74 165 100°C, 212°F

Finish Code: 1=Plain Brass


Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–25
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Standard Spray Sprinklers


ILLUSION™

Concealed Standard Coverage Pendent Sprinklers


K Factor K= 161 (11.2)
3
Thread Size ⁄4" NPT

Approvals UL, C-UL

71°C (160°F), - Sprinkler - 59°C (139°F) - Cover Plate,


Temperature
100°C (212°F) - Sprinkler - 74°C (165°F) - Cover Plate

Chrome, Brush Chrome, Brass, Signal White, Grey


Cover Plate Finish
White, Pure White, Custom

SIN TY5521

Wrench Type W-TYPE 18

Tech Data Sheet TFP184

Extra large orifice/Special hazard • Coverage per NFPA 13 • Available with optional dust and air seal • The ILLUSION is concealed
in an enclosed escutcheon plate with flat cover for use in those applications where architecturally sensitive areas such as casinos,
hotel lobbies, office buildings, churches, and restaurants

ILLUSION, K=161 (11.2), 3 ⁄4" NPT K=161 [11.2] • 3 ⁄4” NPT • TFP184
Approvals &
Part No. Temp.
Concealed Pendent • K=161 [11.2] Finish Listings
3
⁄4” NPT • SIN SR: TY5521 Code
SIN TY5521

UL
°C °F

507111160 71 [160] 1 √
507111212 100 [212] 1 √

Cover Plate
Part No. Temp. For use with
54,0mm ±9,5mm Cover Plate
Cover Sprinkler Finish
(2-1/8"±3/8") °C °F
Plate Temp.
568921135 59 139 68°C, 155°F Brass
568921165 74 165 93°C, 200°F Brass
568920135 59 139 68°C, 155°F Grey White (RAL9002)
568920165 74 165 93°C, 200°F Grey White (RAL9002)
568923135 59 139 68°C, 155°F Pure White (RAL9010)
9,5 to 28,6 mm 568923165 74 165 93°C, 200°F Pure White (RAL9010)
(3/8" to 1-1/8") 568924135 59 139 68°C, 155°F Signal White (RAL9003)
568924135 74 165 93°C, 200°F Signal White (RAL9003)
568928135 59 139 68°C, 155°F Brushed Chrome
568928165 74 165 93°C, 200°F Brushed Chrome
568929135 59 139 68°C, 155°F Chrome
Clean Room Seal 568929165 74 165 93°C, 200°F Chrome
56892X135 59 139 68°C, 155°F Custom
56892X165 74 165 93°C, 200°F Custom

Clean Room Seal


Approvals & Listings
Part No.
UL

569081001 √

COVER AIR
PLATE AND DUST
SEAL
Finish Code: 1=Plain Brass
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–26
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Extended Coverage Sprinklers
Intended for protection of areas larger than those specified in standard installation rules and specific light,
ordinary and extra hazard occupancies.
- Airports - Libraries

- Assembly Spaces - Loading Docks

- “Big Box” Retailing - Parking Garages

- Colleges/Universities - Schools

- Hotels - Transportation Terminals

- Hospitals

www.tyco-fire.com 1–27
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Extended Coverage Sprinklers


EC-25
Upright
K Factor K= 363 (25.2)

Thread Size 1" NPT or ISO 7-R1

Standard Response = UL, C-UL, FM, NYC


Approvals
Quick Response = CMDA, CMSA

Temperature 74°C (165°F), 100°C (212°F)

Sprinkler Finish Natural Brass

SIN TY9128

Wrench Type W-TYPE 1

Tech Data Sheet TFP213

For use in high density applications such as “big box” retailing, extra hazard, and high-piled storage occupancies • Solder type •
CMDA and CMSA Applications and FM Approved for storage and non-storage applications • Minimum operating pressure of 0,48
bar (7 psi) • The maximum coverage area per sprinkler is 18,2 m² (196 ft.²), which is almost double the area offered by standard
coverage sprinklers used for similar applications.

EC-25, K=363 (25.2), 1" ISO or NPT


Upright • K=363 [25.2] K=363 [25.2] • 1” NPT or ISO 7-R1 • TFP213
1” NPT or ISO • SIN TY9128 Upright Part No. Temperature Approvals & Listings

Academy
of Russia
Finish

PAVUS
1" NPT 1" ISO 7-R1

Fire
Code FM
°C °F

UL
SIN TY9128 SIN TY9128

584501165 584511165 74 [165] 1 √ √ √ √


584501214 584511214 100 [212] 1 √ √ √ √

95,3 mm
(3-3/4")

Finish Code: 1=Plain Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–28
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Extended Coverage Sprinklers
EC-11 & EC-14
Upright, Pendent & Recessed Pendent
K Factor K= 161 (11.2) • K= 201 (14.0)
3
Thread Size ⁄ 4" NPT

Approvals UL, C-UL, FM, NYC

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F), Open

Escutcheon Style 30 • Style 40 • Style 60

Escutcheon Finish White Coated, Chrome Plated, Brass Plated

Natural Brass, Chrome Plated, Signal White,


Sprinkler Finish
Jet Black, Lead Coated

SIN TY5137, TY5237, TY6137, TY6237

Wrench Type W-TYPE 3 / W-TYPE 22 (for recessed escutcheons)

Tech Data Sheet TFP220

Light hazard/Ordinary hazard • 3 mm bulb • Designed for maximum coverage applications of 37,2 m2 (400 ft 2) 4,3 m x 4,3 m (14' x
14') up to 6,1 m x 6,1 m (20' x 20') • Low profile decorative glass bulb spray sprinklers • Series EC-11 and EC-14 Sprinklers feature
a UL and C-UL Listing that permits their use with unobstructed or non-combustible obstructed ceiling construction as defined and
permitted by NFPA 13, as well as a specific application listing for use under concrete tees.

K=160 [11.2] • 3 ⁄4” NPT • TFP220


EC-11, K=160 (11.2) Part No. Temp. Approvals & Listings
Finish

PAVUS
Upright • K=160 [11.2] Upright Pendent
FM
°C °F Code

UL
3
⁄4" NPT • SIN TY5137 SIN TY5137 SIN TY5237

518941135 518931135 57 [135] 1 √* √ √


518941155 518931155 68 [155] 1 √* √ √
518941175 518931175 79 [175] 1 √*† √ √
518941200 518931200 93 [200] 1 † √ √
518941286 518931286 141 [286] 1 † √† √
61,9 mm 518941000 518931000 Open 1 - - √
(2-7/16")
518944135 518934135 57 [135] 4 √* √ √
518944155 518934155 68 [155] 4 √* √ √
518944175 518934175 79 [175] 4 √*† √ √
518944200 518934200 93 [200] 4 † √ √
518944286 518934286 141 [286] 4 † √† √
518944000 518934000 Open 4 - - √
Pendent • K=160 [11.2] 518945155 518935155 68 [155] 5 √* √ √
3
⁄4" NPT • SIN TY5237 518945200 518935200 93 [200] 5 √* √ √
518947135 518937135 57 [135] 7 √* √† √
518947155 518937155 68 [155] 7 √* √† √
518947175 518937175 79 [175] 7 √*† √† √
518947200 518937200 93 [200] 7 † √† √
518947286 518937286 141 [286] 7 † √† √
61,9 mm 518947000 518937000 Open 7 - - √
(2-7/16")
518949135 518939135 57 [135] 9 √* √ √
518949155 518939155 68 [155] 9 √* √ √
518949175 518939175 79 [175] 9 √*† √ √
518949200 518939200 93 [200] 9 † √ √
518949286 518939286 141 [286] 9 † √† √
518949000 518939000 Open 9 - - √
√=Approved
* Pendent Only for Light Hazard
 Light Hazard Only
† Recessed Pendent Not Approved
 Ordinary Hazard Only
Finish Code: 1=Plain Brass, 4=Signal White Polyester RAL9003, 5=Jet Black Polyester RAL9005, 7=Lead Coated, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–29
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Extended Coverage Sprinklers

EC-14, K=200 (14.0), 3 ⁄4" NPT


Upright • K=200 [14.0] K=200 [14.0] • 3 ⁄4” NPT • TFP220
3
⁄4" NPT • SIN TY6137 Part No. Temp. Approvals & Listings

Academy
of Russia
Finish

PAVUS
Upright Pendent

Fire
FM
°C °F Code

UL
SIN TY6137 SIN TY6237

518961135 518951135 57 [135] 1 √* √ √ √


518961155 518951155 68 [155] 1 √* √ √ √
61,9 mm 518961175 518951175 79 [175] 1 √*† √ √ √
(2-7/16")
518961200 518951200 93 [200] 1 † √ √ √
518961286 518951286 141 [286] 1 † √† √ √
518961000 518951000 Open 1 - - √ √
518964135 518954135 57 [135] 4 √* √ √ √
518964155 518954155 68 [155] 4 √* √ √ √
518964175 518954175 79 [175] 4 √*† √ √ √
Pendent • K=200 [14.0]
518964200 518954200 93 [200] 4 † √ √ √
3
⁄4" NPT • SIN TY6237 518964286 518954286 141 [286] 4 † √† √ √
518964000 518954000 Open 4 - - √ √
518965155 518955155 68 [155] 5 √* √ √ √
518965200 518955200 93 [200] 5 √* √ √ √
518967135 518957135 57 [135] 7 √* √† √ √
518967155 518957155 68 [155] 7 √* √† √ √
61,9 mm 518967175 518957175 79 [175] 7 √*† √† √ √
(2-7/16") 518967200 518957200 93 [200] 7 † √† √ √
518967286 518957286 141 [286] 7 † √† √ √
518967000 518957000 Open 7 - - √ √
518969135 518959135 57 [135] 9 √* √ √ √
518969155 518959155 68 [155] 9 √* √ √ √
518969175 518959175 79 [175] 9 √*† √ √ √
518969200 518959200 93 [200] 9 † √ √ √
518969286 518959286 141 [286] 9 † √† √ √
518969000 518959000 Open 9 - - √ √
√=Approved
* Pendent Only for Light Hazard
 Light Hazard Only
† Recessed Pendent Not Approved
 Ordinary Hazard Only

Finish Code: 1=Plain Brass, 4=Signal White Polyester RAL9003, 5=Jet Black Polyester RAL9005, 7=Lead Coated, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–30
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Extended Coverage Sprinklers
EC-8
Pendent & Recessed Pendent
K Factor K= 115 (8.0)
3
Thread Size ⁄ 4" NPT

Approvals UL, C-UL, FM, NYC

Temperature 57°C (135°F), 68°C (155°F)

Escutcheon Style 30 • Style 40

Escutcheon Finish Natural Brass, Signal White, Chrome Plated

Sprinkler Finish Natural Brass, Signal White Polyester, Chrome Plated

SIN TY4232

Wrench Type W-TYPE 3 / W-TYPE 23 (for recessed escutcheons)

Tech Data Sheet TFP223

Light hazard • 3 mm bulb • Covers areas as large as 6,1 m x 6,1 m (20' x 20') • The recessed version of the EC-8, intended for use
in areas with a finished ceiling, uses either of the two-piece Recessed Escutcheon • The Series EC-8 Extended Coverage Pendent
Sprinklers are decorative glass bulb sprinklers designed for use in light hazard occupancies

EC-8, K=115 (8.0), 3 ⁄4" NPT


Pendent • K=115 [8.0] K=115 [8.0] • 3 ⁄4” NPT • TFP223
3
⁄4" NPT • SIN TY4232 Part No. Temp. Approvals & Listings
Finish
Pendent

FM
°C °F Code

UL
SIN TY4232

508011135 57 [135] 1 √ √
54,0 mm 508011155 68 [155] 1 - √
(2-1/8") 508014135 57 [135] 4 √‡ √
508014155 68 [155] 4 - √
508019135 57 [135] 9 √‡ √
508019155 68 [155] 9 - √
√=Approved
‡ Recessed Pendent Style 30 Escutcheon only is Approved
† Recessed Pendents Not Approved

Finish Code: 1=Plain Brass, 4=Signal White Polyester RAL9003, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–31
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Extended Coverage Sprinklers


EC-8C
Pendent & Recessed Pendent
K Factor K= 115 (8.0)

Thread Size 3⁄4" NPT

Approvals UL

Temperature 68°C/155°F, 93°C/200°F

Escutcheon Style 30 • Style 40

Natural Brass, Signal White, Pure White, Jet Black,


Escutcheon Finish
Chrome Plated

Natural Brass, Signal White, Pure White, Jet Black,


Sprinkler Finish
Chrome Plated

SIN TY4282

Wrench Type W-TYPE 6 / W-TYPE 7 (for recessed escutcheons)

Tech Data Sheet TFP226

Light hazard • 3 mm bulb • Specifically designed for use in long, narrow spaces such as corridors or hallways with a maximum
coverage area of 8,5 m x 3,1 m (28' by 10') • The recessed version of the EC-8C, intended for use in areas with a finished ceiling,
uses either the two-piece Recessed Escutcheon • The Series EC-8C Extended Coverage Pendent Sprinklers are decorative glass
bulb sprinklers designed for use in light hazard occupancies.

EC-8C, K=115 (8.0), 3 ⁄4" NPT


Pendent • K=115 [8.0] K=115 [8.0] • 3 ⁄4” NPT • TFP223
3
⁄4" NPT • SIN TY4282 Part No. Temp. Approvals & Listings
Finish
Pendent
°C °F Code

UL
SIN TY4282

573511155 68 [155] 1 √
573511200 93 [200] 1 √
57,2 mm
573513155 68 [155] 3 √
(2-1/4")
573513200 93 [200] 3 √
573514155 68 [155] 4 √
573514200 93 [200] 4 √
573515155 68 [155] 5 √
573515200 93 [200] 5 √
573519155 68 [155] 9 √
573519200 93 [200] 9 √
√=Approved

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 5=Jet Black Polyester RAL9005, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–32
Finish Code: 1=Plain Brass, 4=Signal White Polyester RAL9003, 9=Chrome Plated
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Extended Coverage Sprinklers
EC-5
Pendent & Recessed Pendent
K Factor K= 80 (5.6)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, FM, NYC

Temperature 57°C (135°F), 68°C (155°F)

Escutcheon Style 50

Escutcheon Finish Signal White, Chrome Plated, Brass Plated

Sprinkler Finish Natural Brass, Chrome Plated, Signal White Polyester

SIN TY3232

Wrench Type W-TYPE 6 / W-TYPE 7 (for recessed escutcheons)

Tech Data Sheet TFP228

Light hazard • 3 mm bulb • Coverage up to 6,1 m x 6,1 m (20' x 20')

EC-5, K=80 (5.6), 1 ⁄ 2" NPT


Pendent • K=80 [5.6] K=80 [5.6] • 1 ⁄ 2” NPT • TFP228
1
⁄ 2" NPT • SIN TY3232 Part No. Temp. Approvals & Listings
Finish
Pendent

FM
°C °F Code

UL
SIN TY3232

510511135 57 [135] 1 - √
52,4 mm 510511155 68 [155] 1 √ √
(2-1/16") 510513135 57 [135] 3 - √
510513155 68 [155] 3 √ √
510514135 57 [135] 4 - √
510514155 68 [155] 4 √ √
510519135 57 [135] 9 - √
510519155 68 [155] 9 √ √

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–33
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Extended Coverage Sprinklers


EC-5

Horizontal Sidewall & Recessed Horizontal Sidewall


K Factor K= 80 (5.6)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, FM, NYC

Temperature 57°C (135°F), 68°C (155°F), 93°C (200°F)

Escutcheon Style 50

Escutcheon Finish Signal White, Chrome Plated, Brass Plated

Signal White, Pure White, Natural Brass,


Sprinkler Finish
Chrome Plated

SIN TY3302

Wrench Type W-TYPE 6 / W-TYPE 7 (for recessed escutcheons)

Tech Data Sheet TFP298

Light hazard • 3 mm bulb • Coverage up to 4,9 m x 7,3 m (16' x 24') • Designed for use in hydraulically calculated sprinkler systems in
commercial occupancies such as churches, restaurant seating areas, hotels, educational facilities, offices, etc.

EC-5, K=80 (5.6), 1 ⁄ 2" NPT


K=80 [5.6] • 1 ⁄ 2” NPT • TFP298
Horizontal Sidewall • K=80 [5.6]
1
⁄ 2" NPT • SIN TY3302 Part No. Temp. Approvals & Listings
Finish
HSW

FM
°C °F Code

UL
SIN TY3302

510531135 57 [135] 1 - √
63,5 mm 510531155 68 [155] 1 √ √
(2-1/2") 510531200 93 [200] 1 - √
510533135 57 [135] 3 - √
510533155 68 [155] 3 √ √
510533200 93 [200] 3 - √
510534135 57 [135] 4 - √
510534155 68 [155] 4 √ √
510534200 93 [200] 4 - √
510539135 57 [135] 9 - √
510539155 68 [155] 9 √ √
510539200 93 [200] 9 - √

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–34
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Extended Coverage Sprinklers
TY-FRB

Horizontal Sidewall & Recessed Horizontal Sidewall


K Factor K= 80 (5.6) • K= 115 (8.0)
1
Thread Size ⁄2" NPT • 3 ⁄4" NPT

Approvals UL, C-UL, FM, NYC

Temperature 57°C (135°F), 68°C (155°F), 79°C (175°F)

Escutcheon Style 10 • Style 20 • Style 30 • Style 40

Escutcheon Finish White Coated, Chrome Plated, Brass Plated

Natural Brass, Pure White, Signal White, Jet Black,


Sprinkler Finish
Chrome Plated

SIN TY3332, TY4332

Wrench Type W-TYPE 6 / W-TYPE 7 (for recessed escutcheons)

Tech Data Sheet TFP296

Light hazard • 3 mm bulb • Two-piece escutcheon converts sidewall sprinklers into low profile sprinkler assemblies with coverage
areas up to 4,9 m x 6,7 m (16' x 22') for K=5.6 and 4,9 m x 7,3 m (16' x 24') for K=8.0 • Provides 19,1 mm NPT (3 ⁄4") of horizontal
adjustment from the recessed sidewall position • Quick & Standard Response (see tech data sheet) • Decorative sprinklers designed
for use in hydraulically calculated sprinkler systems in light hazard, commercial occupancies such as churches, restaurant seating
areas, hotels, educational facilities, offices, etc.

TY-FRB, K=80 (5.6), 1 ⁄ 2" NPT


Horizontal Sidewall • K=80 [5.6] K=80 [5.6] • 1 ⁄ 2” NPT • TFP296
1
⁄ 2" NPT • SIN TY3332 Part No. Temp. Approvals & Listings
Belarusian
Ukrainian

Academy
of Russia
Finish
PAVUS

HSW

TSU
VKF
Fire
FM

°C °F Code
UL

SIN TY3332

573761135 57 [135] 1 √‡ √ √ √ √ √ √ √
573761155 68 [155] 1 √‡ √ √ √ √ √ √ √
66,7 mm 573761175 79 [175] 1 √‡ √ √ √ √ √ √ √
(2-5/8") 573763135 57 [135] 3 √‡ √ √ √ √ √ √ √
573763155 68 [155] 3 √‡ √ √ √ √ √ √ √
573763175 79 [175] 3 √‡ √ √ √ √ √ √ √
573764135 57 [135] 4 √‡ √ √ √ √ √ √ √
573764155 68 [155] 4 √‡ √ √ √ √ √ √ √
573764175 79 [175] 4 √‡ √ √ √ √ √ √ √
573765135 57 [135] 5 √‡ √ √ √ √ √ √ √
573765155 68 [155] 5 √‡ √ √ √ √ √ √ √
573765175 79 [175] 5 √‡ √ √ √ √ √ √ √
573769135 57 [135] 9 √‡ √ √ √ √ √ √ √
573769155 68 [155] 9 √‡ √ √ √ √ √ √ √
573769175 79 [175] 9 √‡ √ √ √ √ √ √ √
√=Approved
‡ Recessed Style 10 Escutcheon Not Approved

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 5=Jet Black Polyester RAL9005, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–35
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Extended Coverage Sprinklers


TY-FRB - Horizontal Sidewall & Recessed Horizontal Sidewall

TY-FRB, K=115 (8.0), 3 ⁄4" NPT


Horizontal Sidewall • K=115 [8.0] K=115 [8.0] • 3 ⁄4” NPT • TFP296
3
⁄4" NPT • SIN TY4332 Part No. Temp.

Belarusian

Academy
of Russia
Finish

PAVUS
HSW

TSU
Fire
FM
°C °F Code

UL
SIN TY4332

573961135 57 [135] 1 √‡ √ √ √ √ √
573961155 68 [155] 1 √‡ √ √ √ √ √
573961175 79 [175] 1 √ √ √ √ √ √
71,5 mm
573963135 57 [135] 3 √‡ √ √ √ √ √
(2-13/16")
573963155 68 [155] 3 √‡ √ √ √ √ √
573963175 79 [175] 3 √ √ √ √ √ √
573964135 57 [135] 4 √‡ √ √ √ √ √
573964155 68 [155] 4 √‡ √ √ √ √ √
573964175 79 [175] 4 √ √ √ √ √ √
573965135 57 [135] 5 √‡ √ √ √ √ √
573965155 68 [155] 5 √‡ √ √ √ √ √
573965175 79 [175] 5 √ √ √ √ √ √
573969135 57 [135] 9 √‡ √ √ √ √ √
573969155 68 [155] 9 √‡ √ √ √ √ √
573969175 79 [175] 9 √ √ √ √ √ √
√=Approved
‡ Recessed Style 40 Escutcheon Not Approved

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 5=Jet Black Polyester RAL9005, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–36
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Extended Coverage Sprinklers
ELO SW-20/SW-24
Horizontal Sidewall
K Factor K= 161 (11.2)
3
Thread Size ⁄ 4" NPT

Approvals UL, C-UL, NYC

Temperature 68°C (155°F), 93°C (200°F)

Sprinkler Finish Natural Brass, Chrome Plated, Signal White

SIN TY5332, TY5337

Wrench Type W-TYPE 3

Tech Data Sheet TFP230

Extended Coverage Ordinary Hazard (ECOH) • 3 mm bulb • SW-20 Listed to a 4,9 m (16'-0") wide and a 6,1 m (20'-0") throw
maximum coverage area, SW-24 Listed to a 4,9 m (16'-0") wide and a 7,3 m (24'-0") throw maximum coverage area • Standard
Response, Extended Coverage Ordinary Hazard (ECOH) Horizontal Sidewall Sprinklers are decorative glass bulb sprinklers designed
for use in ordinary hazard occupancies per NFPA 13

ELO SW-20, K=161 (11.2), 3 ⁄4" NPT


Horizontal Sidewall • K=161 [11.2] K=161 [11.2] • 3 ⁄4” NPT • TFP230
3
⁄4" NPT • SIN TY5332 Part No. Temp. Approvals & Listings
Finish
HSW
°C °F Code

UL
SIN TY5332

510721155 68 [155] 1 √
510721200 93 [200] 1 √
510724155 68 [155] 4 √
510724200 93 [200] 4 √
79,4 mm 510729155 68 [155] 9 √
(3-1/8") 510729200 93 [200] 9 √

ELO SW-24, K=161 (11.2), 3 ⁄4" NPT


Horizontal Sidewall • K=161 [11.2] K=161 [11.2] • 3 ⁄4” NPT • TFP230
3
⁄4" NPT • SIN TY5337 Part No. Temp. Approvals & Listings
Finish
HSW
°C °F Code
UL

SIN TY5337

510731200 93 [200] 1 √
510734200 93 [200] 4 √
510739200 93 [200] 9 √

79,4 mm
(3-1/8")

Finish Code: 1=Plain Brass, 4=Signal White Polyester RAL9003, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–37
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Extended Coverage Sprinklers


TY-FRL

Horizontal Sidewall
K Factor K= 80 (5.6) • K= 115 (8.0)
1
Thread Size ⁄2" NPT • 3 ⁄4" NPT

Approvals UL, C-UL, FM, NYC

Temperature 74°C (165°F)

Sprinkler Finish Natural Brass, Chrome Plated

SIN TY3322, TY4322

Wrench Type W-TYPE 9

Tech Data Sheet TFP280

Light hazard • Solder type • Coverage up to 4,9 m (16 feet) wide by 7,3 m (24 feet) long, they are designed for installation along a
wall or the side of a beam and just beneath a smooth, flat, horizontal ceiling • Designed for use in commercial occupancies such as
churches, restaurant seating areas, hotels, educational facilities, offices, etc.

TY-FRL, K=80 (5.6), 1 ⁄ 2" NPT


Horizontal Sidewall • K=80 [5.6] K=80 [5.6] • 1 ⁄ 2” NPT • TFP280
1
⁄ 2" NPT • SIN TY3322 Part No. Temp. Approvals & Listings
Finish
HSW

FM
°C °F Code

UL
SIN TY3322

589701165 74 [165] 1 √ √
589709165 74 [165] 9 √ √

85,7 mm
(3-3/8")

TY-FRL, K=115 (8.0), 3 ⁄4" NPT


Horizontal Sidewall • K=115 [8.0] K=115 [8.0] • 3 ⁄4” NPT • TFP280
3
⁄4" NPT • SIN TY4322 Part No. Temp. Approvals & Listings
Finish
HSW
FM

°C °F Code
UL

SIN TY4322

581701165 74 [165] 1 √ √
581709165 74 [165] 9 √ √

85,7 mm
(3-3/8")

Finish Code: 1=Plain Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–38
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Extended Coverage Sprinklers
CHEC
Concealed Horizontal Extended Coverage Sidewall
K Factor K= 115 (8.0)
3
Thread Size ⁄4" NPT

Approvals UL, C-UL, NYC

Temperature 68°C (155°F) - Sprinkler, 59°C (139°F) - Cover Plate

Cover Plate Finish Signal White, Pure White, Chrome, Custom

SIN TY4332

Wrench Type W-TYPE 7

Tech Data Sheet TFP265

Light hazard • 3 mm bulb • Coverage up to 4,9 m x 4,9 m (16' x 16') • Lowest flows & pressures allowed by NFPA 13 • 12,7 mm (1 ⁄ 2")
adjustment • 12" maximum deflector distance from ceiling • No “Slots” in cover plate • It is the best choice for architecturally
sensitive areas such as dormitories, hotel rooms, reception areas, office buildings, banquet facilities, conference rooms,
and hospitals.

K=115 [8.0] • 3 ⁄4” NPT • TFP265


CHEC, K=115 (8.0), 3 ⁄4" NPT Part No. Temp. Approvals & Listings

Academy of
Belarusian
Horizontal Sidewall • K=115 [8.0] Finish

Russia
3
⁄4" NPT • SIN TY4332 HSW

Fire
°C °F Code

UL
SIN TY4332

513963155 68 [155] 3 √ √ √

Cover Plate
Part No. Temp.
Cover Plate
Cover
°C °F Finish
Plate
563963135 59 139 Pure White (RAL9010)
563964135 59 139 Signal White (RAL9003)
563969135 59 139 Chrome
56396X135 59 139 Custom

(7/8" to 1-3/8") 42,9 mm


22,2 to 34,9 mm (1-11/16")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–39
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Extended Coverage Sprinklers


ELOC
Extra Large Orifice Concealed Pendent
K Factor K= 161 (11.2)
3
Thread Size ⁄4" NPT

Approvals UL, C-UL, NYC

71°C (160°F) – Sprinkler - 59°C (139°F) – Cover Plate,


Temperature
100°C (212°F) – Sprinkler - 74°C (165°F) – Cover Plate

Chrome Plated, Brass Plated, Signal White,


Cover Plate Finish
Grey White, Custom

SIN TY5522

Wrench Type W-TYPE 18

Tech Data Sheet TFP250

Light hazard • Extra Large Orifice Concealed (ELOC) Pendent Sprinklers are decorative, fast response solder type sprinklers
featuring a flat cover plate designed to conceal the sprinkler • Covers 37,2 m2 (400 sq. ft.) using less pressure than a standard 12,7
mm (1 ⁄ 2") sprinkler at 20,3 m2 (225 sq. ft.) • Available with optional dust and air seal • Concealed in an enclosed escutcheon plate
with flat cover for use in those applications where aesthetics is a primary consideration.

ELOC, K=161 (11.2), 3 ⁄4" NPT K=161 [11.2] • 3 ⁄4” NPT • TFP250
Part No. Temp. Approvals & Listings
Concealed Pendent • K=161 [11.2] Finish
SIN TY5522

UL
3
⁄4” NPT • SIN TY5522 °C °F Code

507011160 71 [160] 1 √
507011212 100 [212] 1 √

Cover Plate
54,0 mm ±9,5 mm
Part No. Temp. For use with
Cover Plate
(2-1/8"±3/8") Cover Sprinkler Finish
°C °F
Plate Temp.
568921135 59 139 68°C, 155°F Brass
568921165 74 165 93°C, 200°F Brass
568920135 59 139 68°C, 155°F Grey White (RAL9002)
568920165 74 165 93°C, 200°F Grey White (RAL9002)
568923135 59 139 68°C, 155°F Pure White (RAL9010)
9,5 to 28,6 mm
568923165 74 165 93°C, 200°F Pure White (RAL9010)
(3/8" to 1-1/8")
568924135 59 139 68°C, 155°F Signal White (RAL9003)
568924135 74 165 93°C, 200°F Signal White (RAL9003)
568929135 59 139 68°C, 155°F Chrome
568929165 74 165 93°C, 200°F Chrome
56892X135 59 139 68°C, 155°F Custom
56892X165 74 165 93°C, 200°F Custom
Clean Room Seal

Clean Room Seal


Approvals
& Listings
Part No.
UL

569081001 √

AIR
COVER
AND DUST
PLATE
SEAL Finish Code: 1=Plain Brass
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–40
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Extended Coverage Sprinklers
RFII

Concealed Pendent
K Factor K= 80 (5.6)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, NYC

68°C (155°F) - Sprinkler 59°C (139°F) - Cover Plate,


Temperature
93°C (200°F) - Sprinkler 74°C (165°F) - Cover Plate

Chrome, Brass, Pure White, Signal White,


Cover Plate Finish
Grey White, Jet Black, Custom

SIN TY3532

Wrench Type RFII

Tech Data Sheet TFP260

Light hazard • 3 mm bulb • Maximum 6,1 m x 6,1 m (20' x 20') QR Listing • Internally threaded closure with 12,7 mm (1 ⁄ 2") of
adjustment • Separable, two-piece design of the mounting cup and cover allows installation of the sprinklers and pressure testing
of the fire protection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling •
Concealed in an enclosed escutcheon plate with flat cover for use in those applications where aesthetics is a primary consideration.

RFII, K=80 (5.6), 1 ⁄ 2" NPT or ISO K=80 [5.6] • 1 ⁄ 2” NPT • TFP260
Part No. Temp. Approvals & Listings
Concealed Pendent • K=80 [5.6] Finish
1
⁄ 2” NPT • SIN TY3532 RFII

UL
°C °F Code
SIN TY3532

517941155 68 [155] 1 √
517941200 93 [200] 1 √

Cover Plate
44,5 to 57,2 mm
(1-3/4" to 2-1/4")
Part No. Temp. For use with
Cover Plate
Cover Sprinkler Finish
°C °F
Plate Temp.
567921135 59 139 68°C, 155°F Brass
567921165 74 165 93°C, 200°F Brass
4,8 to 17,5 mm 567920135 59 139 68°C, 155°F Grey White (RAL9002)
(3/16" to 11/16") 567920165 74 165 93°C, 200°F Grey White (RAL9002)
567923135 59 139 68°C, 155°F Pure White (RAL9010)
567923165 74 165 93°C, 200°F Pure White (RAL9010)
567924135 59 139 68°C, 155°F Signal White (RAL9003)
567924165 74 165 93°C, 200°F Signal White (RAL9003)
567926135 59 139 68°C, 155°F Jet Black (RAL9005)
597926165 74 165 93°C, 200°F Jet Black (RAL9005)
567929135 59 139 68°C, 155°F Chrome
567929165 74 165 93°C, 200°F Chrome
56792X135 59 139 68°C, 155°F Custom
56792X165 74 165 93°C, 200°F Custom

Finish Code: 1=Plain Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–41
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Extended Coverage Sprinklers


RFII-MRI

Concealed Pendent
K Factor K= 80 (5.6)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL

68°C (155°F) - Sprinkler 59°C (139°F) - Cover Plate,


Temperature
93°C (200°F) - Sprinkler 74°C (165°F) - Cover Plate

Cover Plate Finish Brass, Signal White, Grey White, Jet Black, Custom

SIN TY3537

Wrench Type RFII

Tech Data Sheet TFP262

Non-magnetic flat-plate concealed sprinkler for MRI room applications • Tested up to 7 Tesla (standard MRI apparatus is typically
3 Tesla) • Concealed in an enclosed escutcheon plate with flat cover • Separable, two-piece design of the mounting cup and cover
allows installation of the sprinklers and pressure testing of the fire protection system prior to installation of a suspended ceiling
or application of the finish coating to a fixed ceiling • Internally threaded closure with 12,7 mm (1 ⁄ 2") of adjustment • Extended
coverage option designed to protect standardised MRI rooms with fewer sprinklers (up to 5 fewer than standard coverage) •
Maximum 6,1 m x 6,1 m (20' x 20') QR Listing

RFII-MRI, K=80 (5.6), 1 ⁄ 2" NPT K=80 [5.6] • 1 ⁄ 2” NPT • TFP262


Part No. Temp. Approvals & Listings
Concealed Pendent • K=80 [5.6] Finish
1
⁄ 2” NPT • SIN TY3537 RFII-MRI

UL
°C °F Code
SIN TY3537

518021155 68 [155] 1 √
518021200 93 [200] 1 √

44,5 to 57,2 mm Cover Plate


(1-3/4" to 2-1/4")
Part No. Temp. For use with
Cover Plate
Cover Sprinkler Finish
°C °F
Plate Temp.
567941135 59 139 68°C, 155°F Brass
4,8 to 17,5 mm 567941165 74 165 93°C, 200°F Brass
(3/16" to 11/16") 567940135 59 139 68°C, 155°F Grey White (RAL9002)
567940165 74 165 93°C, 200°F Grey White (RAL9002)
567944135 59 139 68°C, 155°F Signal White (RAL9003)
567944165 74 165 93°C, 200°F Signal White (RAL9003)
567946135 59 139 68°C, 155°F Jet Black (RAL9005)
597946165 74 165 93°C, 200°F Jet Black (RAL9005)
56794X135 59 139 68°C, 155°F Custom
56794X165 74 165 93°C, 200°F Custom

Finish Code: 1=Plain Brass


Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–42
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Extended Coverage Sprinklers
RFIII

Flat Plate Concealed Horizontal Extended Coverage Sidewall


K Factor K= 115 (8.0)
3
Thread Size ⁄4" NPT

Approvals UL, C-UL

Temperature 71°C (160°F) - Sprinkler 59°C (139°F) - Cover Plate

Ivory, Beige, Pure White, Signal White, Grey White,


Cover Plate Finish Brown, Black, Brushed Chrome, Brushed Brass,
Custom Paint

SIN TY4522

Wrench Type W-Type 37

Tech Data Sheet TFP270

Light hazard • Decorative, link type, sprinkler featuring a unique flat cover designed to conceal the sprinkler within a wall • The
sprinkler is the best choice for architecturally sensitive areas such as dormitories, hotel rooms, reception areas, office buildings,
banquet facilities, conference rooms, and hospitals • The Model RFIII ECLH Concealed HSW Sprinklers are designed for installation
along a wall or the side of a beam, and beneath a smooth level ceiling.

RFIII, K=115 (8.0), 3 ⁄4" NP

Concealed Pendent • K=115 [8.0] K=115 [8.0] • 3 ⁄4” NPT • TFP270


3
⁄4” NPT • SIN TY4522 Part No. Temp. Approvals & Listings
Finish
69,9 mm ± 3,2 mm 4,8 mm RFIII

UL
°C °F Code
(2-3/4" ± 1/8") (3/16") SIN TY4522

511131160 71 [160] 1 √

Cover Plate
Part No. Temp. For use with
Cover Plate
Cover Sprinkler Finish
°C °F
Plate Temp.
562040135 59 139 71°C, 160°F Ivory (RAL1015)
562042135 59 139 71°C, 160°F Beige (RAL1001)
562043135 59 139 71°C, 160°F Pure White (RAL9010)
562044135 59 139 71°C, 160°F Signal White (RAL9003)
562045135 59 139 71°C, 160°F Grey White (RAL9002)
562046135 59 139 71°C, 160°F Brown (RAL8028)
562047135 59 139 71°C, 160°F Black (RAL9005)
562048135 59 139 71°C, 160°F Brushed Brass
562049135 59 139 71°C, 160°F Brushed Chrome
56204X135 59 139 71°C, 160°F Custom Paint

Finish Code: 1=Plain Brass


Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–43
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Storage Sprinklers
Intended for use in specific storage applications and include a broad offering of early suppression
fast response (ESFR) sprinklers.

- High-Piled Storage - High Challenge Occupancies

- Warehouse - In-Rack Storage

- Box-In-Box Cold Storage - Beneath Open Gridded


Catwalks

1–44
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Storage Sprinklers
ESFR-34
Pendent
K Factor K= 480 (33.6)

Thread Size 1-1/4" NPT or ISO 7-R1-1/4

Approvals FM

Temperature 74°C (165°F), 100°C (212°F)

Sprinkler Finish Natural Brass

SIN TY9286

Wrench Type W-TYPE 26

Tech Data Sheet TFP338

Early Suppression, Fast Response (ESFR) • Solder type • Direct attack on burning fuel by improved heavy sprinkler discharge
• Suppression-mode sprinklers that are especially advantageous as a means of eliminating the use of in-rack sprinklers when
protecting high-piled storage.

ESFR-34, K=480 (33.,6),


1-1/4" ISO or NPT
K=480 [33.6] • 1-1/4” NPT or ISO 7-R1 • TFP338
Upright • K=480 [33.6]
Upright Part No. Temperature Approvals & Listings
1-1/4” NPT or ISO • SIN TY9286
Finish
1-1/4" NPT ISO 7-R1-1/4

FM
°C °F Code
SIN TY9286 SIN TY9286

516811165 516821165 74 [165] 1 √


516811212 516821212 100 [212] 1 √

106,4 mm
(4-3/16")

Finish Code: 1=Plain Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–45
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Storage Sprinklers
EC-25
Upright
K Factor K= 363 (25.2)

Thread Size 1" NPT or ISO 7-R1

Approvals UL, C-UL, FM, NYC

Temperature 74°C (165°F), 100°C (212°F)

Sprinkler Finish Natural Brass

SIN TY9128

Wrench Type W-TYPE 1

Tech Data Sheet TFP213

For use in high density applications such as “big box” retailing, extra hazard, and high-piled storage occupancies • Solder type •
CMDA and CMSA Applications and FM Approved for storage and non-storage applications • Minimum operating pressure of 0,48
bar (7 psi) • The maximum coverage area per sprinkler is 18,2 m² (196 ft.²), which is almost double the area offered by standard
coverage sprinklers used for similar applications.

EC-25, K=363 (25.2), 1" ISO or NPT


Upright • K=363 [25.2] K=363 [25.2] • 1” NPT or ISO 7-R1 • TFP213
1” NPT or ISO • SIN TY9128 Upright Part No. Temperature Approvals & Listings

Academy
of Russia
Finish

PAVUS
1" NPT 1" ISO 7-R1

Fire
FM
°C °F Code

UL
SIN TY9128 SIN TY9128

584501165 584511165 74 [165] 1 √ √ √ √


584501214 584511214 100 [212] 1 √ √ √ √

95,3 mm
(3-3/4")

Finish Code: 1=Plain Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–46
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Storage Sprinklers
ESFR-25
Pendent
K Factor K= 363 (25.2)

Thread Size 1" NPT or ISO 7-R1

Approvals UL, C-UL, FM, NYC, LPCB, VdS, CE

Temperature 74°C (165°F), 100°C (212°F)

Sprinkler Finish Natural Brass

SIN TY9226

Wrench Type W-TYPE 1

Tech Data Sheet TFP312

Early Suppression, Fast Response (ESFR) • Solder type • The TYCO Model ESFR-25 Pendent Sprinklers are listed by UL for Specific
Applications with a ceiling height greater than 13,7 m (45 ft.) up to and including 14,6 m (48 ft.), and a storage arrangement up
to and including 13,1 m (43 ft.) • Direct attack on burning fuel by improved heavy sprinkler discharge • Patented frame design
substantially reduces the frame shadow effects that often produce non-uniformity in spray pattern, novel orifice seal and unique
fast response link design are the very latest in sprinkler technology • Suppression-mode sprinklers that are especially advantageous
as a means of eliminating the use of in-rack sprinklers when protecting high-piled storage.

ESFR-25, K=363 (25.2), 1" ISO or NPT

Pendent • K=363 [25.2]


1” NPT or ISO • SIN TY9226

96,8 mm
(3-13/16")

K=363 [25.2] • 1” ISO or NPT • TFP312


Pendent Part No. Temp. Approvals & Listings
Belarusian

Academy
of Russia
Ukrainian

Finish
CNBOP

PAVUS

T/S/U

1" NPT 1" ISO 7-R1


LPCB

Fire
VdS

FM

°C °F Code
CE

UL

CE

SIN TY9226 SIN TY9226

584411165 584421165 74 [165] 1 √ √ √ √ √ √ √ √ √ √ √ √


584411214 584421214 100 [212] 1 √ √ √ √ √ √ √ √ √ √ √ √

Finish Code: 1=Plain Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–47
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Storage Sprinklers
ESFR-22
Pendent
K Factor K= 320 (22.4)

Thread Size 1" NPT or ISO 7-R1

Approvals UL, C-UL, FM

Temperature 74°C (165°F), 100°C (212°F)

Sprinkler Finish Natural Brass

SIN TY8223

Wrench Type W-TYPE 1

Tech Data Sheet TFP321

Early Suppression, Fast Response (ESFR) • Solder type • Suppression-mode sprinklers that are especially advantageous as a means
of eliminating the use of in-rack sprinklers when protecting high-piled storage • Direct attack on burning fuel by improved heavy
sprinkler discharge • The TYCO Model ESFR-22 Pendent Sprinklers are listed by UL and C-UL for Specific Applications with a ceiling
height of 13,7 m (45 ft.) and a storage arrangement up to and including 12,2 m (40 ft.)

ESFR-22, K=320 (22.4), 1" ISO or NPT

Pendent • K=320 [22.4] K=320 [22.4] • 1” NPT • TFP321


1” NPT or ISO • SIN TY8223
Pendent Part No. Temp. Approvals & Listings
Finish
1" NPT 1" ISO
FM
°C °F Code

UL
SIN TY8223 SIN TY8223

584641165 584651165 74 [165] 1 √ √


584641212 584651212 100 [212] 1 √ √

96,8 mm
(3-13/16")

Finish Code: 1=Plain Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–48
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Storage Sprinklers
ESFR-17
Upright
K Factor K= 242 (16.8)
3
Thread Size ⁄4" NPT or ISO 7-1

Approvals FM, CE

Temperature 74°C (165°F), 100°C (212°F)

Sprinkler Finish Natural Brass

SIN TY7126

Wrench Type W-TYPE 21

Tech Data Sheet TFP316

Early Suppression, Fast Response (ESFR) • Solder type • Unique, upright design and large K-Factor overcome many pendent
obstruction problems • Use of this sprinkler is especially advantageous as a means of eliminating the use of in-rack sprinklers when
protecting rack storage arrangements, Primarily designed for use in ceiling only sprinkler systems.

ESFR-17, K=242 (16.8), 3 ⁄4" ISO or NPT


Upright • K=242 [16.8]
3
⁄4” NPT or ISO • SIN TY7126

92,1 mm
(3-5/8")

K=242 [16.8] • 3 ⁄4” NPT or ISO 7-1 • TFP316


Upright Part No. Temp. Approvals & Listings
Belarusian

Academy
of Russia
Ukrainian

Finish
CNBOP

PAVUS

T/S/U

3 3
⁄4" NPT ⁄4" ISO 7-1
LPCB

Fire
VdS

FM

°C °F1s Code
CE

UL

CE

SIN TY7126 SIN TY7126

584471165 584481165 74 [165] 1 √ √ √ √ √ √ √ √ √ √ √ √


584471214 584481214 100 [212] 1 √ √ √ √ √ √ √ √ √ √ √ √

Finish Code: 1=Plain Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–49
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Storage Sprinklers
ESFR-17
Pendent
K Factor K= 242 (16.8)
Thread Size 3⁄4" NPT
Approvals UL, C-UL, FM
Temperature 74°C (165°F), 100°C (212°F)
Sprinkler Finish Natural Brass
SIN TY7223
Wrench Type W-TYPE 35
Tech Data Sheet TFP317

Early Suppression, Fast Response (ESFR) • Solder type • Primarily designed for use in ceiling only sprinkler systems • Model ESFR-17
Pendent Sprinklers are designed to operate at substantially lower-end head pressures, as compared to ESFR Sprinklers having a
nominal K-factor of 14.0 • They are suppression mode sprinklers that are especially advantageous as a means of eliminating in-rack
sprinklers when protecting high-piled storage.

ESFR-17, K=242 (16.8), 3 ⁄4" ISO or NPT

Pendent • K=242 [16.8] K=242 [16.8] • 3 ⁄4” NPT • TFP317


3
⁄4” NPT or ISO • SIN TY7223
Pendent Part No. Temp. Approvals & Listings

3 3 Finish
⁄4” NPT ⁄4” ISO

FM
°C °F Code

UL
SIN TY7223 SIN TY7223
38,1 mm
584571165 584581165 74 [165] 1 √ √
(1-1/2")
584571214 584581214 100 [212] 1 √ √
60,3 mm
(2-3/8")

Finish Code: 1=Plain Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–50
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Storage Sprinklers
ESFR-17
Pendent
K Factor K= 242 (16.8)
3
Thread Size ⁄4" NPT or ISO 7-1

Approvals FM, VdS, LPCB, CE

Temperature 74°C (165°F), 101°C (214°F)

Sprinkler Finish Natural Brass

SIN TY7226

Wrench Type W-TYPE 21

Tech Data Sheet TFP315

Early Suppression, Fast Response (ESFR) • Solder type • Primarily designed for use in ceiling only sprinkler systems • Model ESFR-17
Pendent Sprinklers are designed to operate at substantially lower-end head pressures, as compared to ESFR Sprinklers having a
nominal K-factor of 201,6 (14.0) • They are suppression mode sprinklers that are especially advantageous as a means of eliminating
in-rack sprinklers when protecting high-piled storage.

ESFR-17, K=242 (16.8), 3 ⁄4" ISO or NPT

Pendent • K=242 [16.8]


3
⁄4” NPT or ISO • SIN TY7226

3/4" NPT

38,1 mm
(1-1/2")

90,5 mm
(3-9/16")

47,6 mm
(1-7/8")

K=242 [16.8] • 3 ⁄4” NPT or ISO 7-1 • TFP315


Pendent Part No. Temp. Approvals & Listings
Belarusian

Academy
of Russia
Ukrainian

Finish
CNBOP

PAVUS

3 3
⁄4" NPT ⁄4" ISO 7-1
LPCB

Fire
TSU
VdS
FM

°C °F Code
CE

SIN TY7226 SIN TY7226

584451165 584461165 74 [165] 1 √ √ √ √ √ √ √ √ √ √


584451214 584461214 101 [214] 1 √ √ √ √ √ √ √ √ √ √

Finish Code: 1=Plain Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–51
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Storage Sprinklers
ESFR-17
Pendent
K Factor K= 242 (16.8)
Thread Size 3⁄4" NPT or ISO 7-R 3/4
Approvals UL, C-UL, FM
Temperature 68°C (155°F), 93°C (200°F)
Sprinkler Finish Natural Brass
SIN TY7236
Wrench Type W-TYPE 35
Tech Data Sheet TFP322

Early Suppression, Fast Response (ESFR) • 3mm bulb type • Primarily designed for use in ceiling only sprinkler systems • Use of
this sprinkler is especially advantageous as a means of eliminating the use of in-rack sprinklers when protecting rack storage
arrangements • Available in two temperature ratings and Listed or Approved accordingly; 68°C (155°F) is UL and C-UL Listed and FM
Approval; and 93°C (200°F) is UL and C-UL Listing only.

ESFR-17, K=242 (16.8), 3 ⁄4" ISO or NPT

Pendent • K=242 [16.8] K=242 [16.8] • 3 ⁄4” NPT • TFP322


3
⁄4” NPT or ISO • SIN TY7236
Pendent Part No. Temp. Approvals & Listings

3 3 Finish
⁄4” NPT ⁄4” ISO

FM
°C °F Code

UL
SIN TY7236 SIN TY7236
38,1 mm
(1-1/2") 584621165 584631165 74 [165] 1 √ √
60,3 mm 584621214 584631214 100 [212] 1 √ √
(2-3/8")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–52
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Storage Sprinklers
ESFR-17
Dry-Type Pendent
K Factor K= 242 (16.8)

Thread Size 1-1 ⁄4" NPT or ISO 7-1

Grooved End 2" Standard Cut Grooved per Tech Data Sheet TFP1898

Approvals UL, FM

Temperature 74°C (165°F), 100°C (212°F)

Sprinkler Finish Natural Brass

SIN TY7229

Wrench Type W-TYPE 26

Tech Data Sheet TFP320

Early Suppression, Fast Response (ESFR) • Solder type • Eliminates in-rack sprinklers for box-in-box applications • Suppression
mode sprinklers that are especially advantageous as a means of eliminating in-rack sprinklers when protecting high-piled box-in-
box refrigerated storage areas • The drop between the inlet and sprinkler remains dry until the sprinkler operates, allowing for a
pendent sprinkler installation on a wet pipe sprinkler system where the dry drop and sprinkler are located in an area subjected to
freezing temperatures • Less costly to install and maintain than pre-action or antifreeze systems • The Model ESFR-17 Dry Type
Pendent Sprinkler is FM Approved and has successfully undergone full-scale fire testing at FM Global, when used in conformance
with applicable FM Global Property Loss Prevention Data Sheets • The Model ESFR-17 Dry Type Sprinklers are primarily used for
ceiling only sprinkler protection and used to protect solid piled, palletized, and rack storage that is subject to freezing temperatures

ESFR-17, K=242 (16.8), 1-1 ⁄4" ISO or NPT


Pendent • K=242 [16.8]
1-1 ⁄4” NPT or ISO • SIN TY7229
K=242 [16.8] • 1-1 ⁄4” NPT or ISO • TFP320
Pendent Part No. Temp. Approvals & Listings

Academy
of Russia
Finish

PAVUS
1-1 ⁄4" NPT 1-1 ⁄4" ISO 7-1

Fire
FM

°C °F Code UL
SIN TY7229 SIN TY7229

914 mm (36") Sprinkler


614411360 I614411360 74 [165] 1 √ √ √ √
614421360 I614421360 100 [212] 1 - √ √ √
762 mm (30") Sprinkler
914mm 614411300 I614411300 74 [165] 1 √ √ √ √
(36”) Sprinkler 614421300 I614421300 100 [212] 1 - √ √ √
584 mm (23") Sprinkler
952,5 mm 614411230 I614411230 74 [165] 1 √ √ √ √
(37.5”) 614421230 I614421230 100 [212] 1 - √ √ √

762 mm
(30”) Sprinkler
795 mm
(31.3”)

584 mm
(23”) Sprinkler
617 mm
(24.3”)

Finish Code: 1=Plain Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–53
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Storage Sprinklers
ESFR-14
Pendent
K Factor K= 201 (14.0)
3
Thread Size ⁄4" NPT or ISO 7-1

Approvals UL, C-UL, FM

Temperature 68°C (155°F), 93°C (200°F)

Sprinkler Finish Natural Brass

SIN TY6236

Wrench Type W-TYPE 34

Tech Data Sheet TFP319

Early Suppression, Fast Response (ESFR) • 3mm bulb type • Designed for the protection of rack storage • Direct attack on burning
fuel by improved heavy sprinkler discharge • They are suppression-mode sprinklers that are especially advantageous as a means of
eliminating the use of in-rack sprinklers when protecting high-piled storage.

ESFR-14, K=201 (14.0), 3 ⁄4" ISO or NPT

Pendent • K=201 [14.0] K=201 [14.0] • 3 ⁄4” NPT or ISO 7-1 • TFP319
3
⁄4” NPT or ISO • SIN TY6236
Pendent Part No. Temp. Approvals & Listings

Academy
of Russia
Finish

PAVUS
3 3
⁄4" NPT ⁄4" ISO 7-1

Fire
VdS
°C °F Code FM

UL
SIN TY6236 SIN TY6236

60,3 mm 584491155 584431155 68 [155] 1 √ √ √ √ √


(2-3/8") 584491200 584431200 93 [200] 1 √ √ √ √ √

Finish Code: 1=Plain Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–54
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Storage Sprinklers
ULTRA K-17
Upright, Control Mode Specific Application
K Factor K= 242 (16.8)
3
Thread Size ⁄4" NPT

Approvals UL, C-UL, FM, NYC

Temperature 68°C (155°F), 93°C (200°F)

Sprinkler Finish Natural Brass

SIN TY7153

Wrench Type W-TYPE 8

Tech Data Sheet TFP330

5 mm bulb • Approved for storage heights of 7,6 m (25') and building heights to 9,1 m (30') • Full-scale fire testing has shown that
the Ultra K17 can control fires with commodities up to Group A plastics, and eliminate the need for in-rack sprinklers.

Ultra K-17, K=242 (16.8), 3 ⁄4" NPT


Upright • K=242 [16.8]
3
⁄4” NPT • SIN TY7153 K=242 [16.8] • 3 ⁄4” NPT • TFP330
Temperature Approvals & Listings

Academy
of Russia
Upright Part No. Finish

Fire
FM
SIN TY7153 °C °F Code

UL
518871155 68 [155] 1 √ √ √
60,3 mm
518871200 93 [200] 1 √ √ √
(2-3/8")

Finish Code: 1=Plain Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–55
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Storage Sprinklers
ULTRA K-17
Upright, Control Mode Specific Application, 286° F
K Factor K= 242 (16.8)
3
Thread Size ⁄4" NPT

Approvals UL, C-UL, FM

Temperature 141°C (286°F)

Sprinkler Finish Natural Brass

SIN TY7103

Wrench Type W-TYPE 8

Tech Data Sheet TFP331

5 mm bulb • Control mode sprinkler

Ultra K-17, K=242 (16.8), 3 ⁄4" NPT


K=242 [16.8] • 3 ⁄4” NPT • TFP331
Upright • K=242 [16.8] Temperature Approvals & Listings
3
⁄4” NPT • SIN TY7103

Academy
of Russia
Upright Part No. Finish

Fire
FM
SIN TY7103 °C °F Code

UL
518871286* 141 [286] 1 √ √ √
* for use with Quell systems
60,3 mm
(2-3/8")

Finish Code: 1=Plain Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–56
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Storage Sprinklers
K17-231
Upright & Pendent
K Factor K= 242 (16.8)
3
Thread Size ⁄4" NPT

Upright= UL, C-UL, FM, NYC


Approvals
Pendent= UL, C-UL, NYC

Temperature 68°C (155°F), 93°C (200°F), 141°C (286°F)

Sprinkler Finish Natural Brass

SIN TY7151, TY7251

Wrench Type W-TYPE 8

Tech Data Sheet TFP332

5 mm bulb • They are “standard response spray sprinklers” which produce a hemispherical water distribution pattern below the
deflector • Low-pressure requirement (as low as 0,5 bar (7 psi)) can save cost by reducing branch line size, taking advantage of
maximised spacing, and upgrading existing densities • Very large orifice sprinkler for use in high challenge storage occupancies.

K17-231, K=242 (16.8), 3 ⁄4" NPT


K=242 [16.8] • 3 ⁄4” NPT • TFP332
Upright • K=242 [16.8] Part No. Temp. Approvals & Listings
3
⁄4” NPT • SIN TY7151

Academy
of Russia
Finish

CNBOP

PAVUS
Upright Pendent

Fire
FM
°C °F Code

UL
SIN TY7151 SIN TY7251

518881155 518891155 68 [155] 1 U √ √ √ √


518881200 518891200 93 [200] 1 U √ √ √ √
60,3 mm 518881286 518891286 141 [286] 1 U √ √ √ √
(2-3/8") U=Upright Approved, √=Both Approved

Pendent • K=242 [16.8]


3
⁄4” NPT • SIN TY7251

60,3 mm
(2-3/8")

Finish Code: 1=Plain Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–57
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Storage Sprinklers
ELO-231B
Upright & Pendent
K Factor K= 161 (11.2)

Thread Size 1 ⁄2" NPT • 3 ⁄4" NPT

Approvals UL, C-UL, FM, NYC

Temperature 68°C (155°F), 93°C (200°F), 141°C (286°F)

Brass, Chrome Plated, Lead Coated, Wax Coated,


Sprinkler Finish
Wax over Lead Coated

SIN TY5151, TY5251, TY5851

Wrench Type W-TYPE 3

Tech Data Sheet TFP342

5 mm bulb • Extra large orifice sprinklers proven for storage occupancies through full-scale fire testing • Can be used as
intermediate level version by adding a guard and shield • Designed to control high challenge fires with relatively low
required pressures

ELO-231B, K=161 (11.2), 3 ⁄4" NPT


K=161 [11.2] • 3 ⁄4” NPT • TFP342
Upright • K=161 [11.2] Part No. Temp. Approvals & Listings
3
⁄4” NPT • SIN TY5151

Belarusian

Academy
of Russia
Finish

CNBOP

PAVUS

T/S/U
Upright Pendent

VdS

Fire
FM
°C °F Code
SIN TY5151 SIN TY5251 UL

505101155 505121155 68 [155] 1 √ √ √ √ √ √ √ √


71,4 mm 505101200 505121200 93 [200] 1 √ √ √ √ √ √ √ √
(2-13/16") 505101286 505121286 141 [286] 1 √ √ √ √ √ √ √ √
505106155 505126155 68 [155] 6 √ U √ √ √ √ √ √
505106200 505126200 93 [200] 6 √ U √ √ √ √ √ √
505106286 505126286 141 [286] 6 √ U √ √ √ √ √ √
505107155 505127155 68 [155] 7 √ U √ √ √ √ √ √
505107200 505127200 93 [200] 7 √ U √ √ √ √ √ √
505107286 505127286 141 [286] 7 √ U √ √ √ √ √ √
Pendent • K=161 [11.2] 505108155 505128155 68 [155] 8 √ U √ √ √ √ √ √
3
⁄4” NPT • SIN TY5251 505108200 505128200 93 [200] 8 √ U √ √ √ √ √ √
505108286 505128286 141 [286] 8 √ U √ √ √ √ √ √
505109155 505129155 68 [155] 9 √ √ √ √ √ √ √ √
505109200 505129200 93 [200] 9 √ √ √ √ √ √ √ √
505109286 505129286 141 [286] 9 √ √ √ √ √ √ √ √
71,4 mm U=Upright Approved, √=Both Approved
(2-13/16")

Finish Code: 1=Plain Brass, 6=Wax Coated, 7=Lead Coated, 8=Wax-Over Lead Coated, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–58
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Storage Sprinklers
ELO-231B, K=161 (11.2), 1 ⁄ 2" NPT
K=161 [11.2] • 1 ⁄ 2” NPT • TFP342
Upright • K=161 [11.2] Part No. Temp. Approvals & Listings
1
⁄ 2” NPT • SIN TY5851
Finish

PAVUS

T/S/U
Upright

VdS
FM
°C °F Code

UL
SIN TY5851

505011155 68 [155] 1 √ √ √ √ √
71,4 mm 505011200 93 [200] 1 √ √ √ √ √
(2-13/16") 505011286 141 [286] 1 √ √ √ √ √
505016155 68 [155] 6 √ √ √ √ √
505016200 93 [200] 6 √ √ √ √ √
505016286 141 [286] 6 √ √ √ √ √
505017155 68 [155] 7 √ √ √ √ √
505017200 93 [200] 7 √ √ √ √ √
505017286 141 [286] 7 √ √ √ √ √
505018155 68 [155] 8 √ √ √ √ √
505018200 93 [200] 8 √ √ √ √ √
505018286 141 [286] 8 √ √ √ √ √
505019155 68 [155] 9 √ √ √ √ √
505019200 93 [200] 9 √ √ √ √ √
505019286 141 [286] 9 √ √ √ √ √

Finish Code: 1=Plain Brass, 6=Wax Coated, 7=Lead Coated, 8=Wax-Over Lead Coated, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–59
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Storage Sprinklers
ELO-231 FRB
Upright & Pendent
K Factor K= 161 (11.2)
1
Thread Size  ⁄ 2" NPT • 3 ⁄4" NPT

Approvals UL, C-UL, FM, NYC, VdS, LPCB

Temperature 68°C (155°F), 93°C (200°F), 141°C (286°F)

Sprinkler Finish Natural Brass, Chrome Plated

SIN TY5131, TY5231, TY5831 (1 ⁄ 2" NPT)

Wrench Type W-TYPE 3

Tech Data Sheet TFP344

3 mm bulb • Extra large orifice sprinklers proven for storage occupancies through full-scale fire testing • Can be used as
intermediate level version by adding a guard and shield • Designed to control high challenge fires with relatively low required
pressures

ELO-231 FRB, K=161 (11.2), 3 ⁄4" NPT


K=161 [11.2] • 3 ⁄4” NPT • TFP344
Upright • K=161 [11.2] Part No. Temp. Approvals & Listings
3
⁄4” NPT • SIN TY5131

Belarusian

Academy
of Russia
Finish
Upright Pendent

LPCB
VdS

Fire
FM
°C °F Code

UL
SIN TY5131 SIN TY5231

505001155 505021155 68 [155] 1 √ √ √ √ √ √


71,4 mm 505001200 505021200 93 [200] 1 √ √ √ √ √ √
(2-13/16") 505001286 505021286 141 [286] 1 √ √ √ √ √ √
505009155 505029155 68 [155] 9 √ √ √ √ √ √
505009200 505029200 93 [200] 9 √ √ √ √ √ √
505009286 505029286 141 [286] 9 √ √ √ √ √ √

Pendent • K=161 [11.2]


3
⁄4” NPT • SIN TY5231

71,4 mm
(2-13/16")

ELO-231 FRB, K=161 (11.2), 1 ⁄ 2" NPT


Upright • K=161 [11.2] K=161 [11.2] • 1 ⁄ 2” NPT • TFP344
1
⁄ 2” NPT • SIN TY5831 Part No. Temp. Approvals & Listings
Finish
Upright
°C °F Code
UL

SIN TY5831

505001155 68 [155] 1 √*
71,4 mm
505001200 93 [200] 1 √*
(2-13/16")
505001286 141 [286] 1 -
505009155 68 [155] 9 -
505009200 93 [200] 9 -
505009286 141 [286] 9 -
* Retrofit Only
Finish Code: 1=Plain Brass, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–60
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Storage Sprinklers
ELO-231
Pendent & Upright
K Factor K= 161 (11.2)
1
Thread Size ⁄ 2" NPT • 3 ⁄4" NPT

Approvals UL, C-UL, FM, NYC

Temperature 74°C (165°F), 100°C (212°F), 141°C (286°F)

Natural Brass, Chrome Plated, Lead Coated,


Sprinkler Finish
Wax Coated, Wax over Lead Coated

SIN TY5111, TY5211, TY5811

Wrench Type W-TYPE 3

Tech Data Sheet TFP340

Solder type • Extra large orifice sprinklers proven for storage occupancies through full-scale fire testing • Can be used as
intermediate level version by adding a guard and shield • Designed to control high challenge fires with relatively low required
pressures

ELO-231, K=161 (11.2), 3 ⁄4" NPT


K=161 [11.2] • 3 ⁄4” NPT • TFP340
Upright • K=161 [11.2] Part No. Temp. Approvals & Listings
3
⁄4” NPT • SIN TY5111
Finish
Upright Pendent

FM
°C °F Code

UL
SIN TY5111 SIN TY5211

501101165 501121165 74 [165] 1 √ √


501101212 501121212 100 [212] 1 √ √
71,4 mm 501101286 501121286 141 [286] 1 √ √
(2-13/16") 501106165 501126165 74 [165] 6 U √
501106212 501126212 100 [212] 6 U √
501106286 501126286 141 [286] 6 U √
501107165 501127165 74 [165] 7 U √
501107212 501127212 100 [212] 7 U √
501107286 501127286 141 [286] 7 U √
Pendent • K=161 [11.2] 501108165 501128165 74 [165] 8 U √
3
⁄4” NPT • SIN TY5211 501108212 501128212 100 [212] 8 U √
501108286 501128286 141 [286] 8 U √
501109165 501129165 74 [165] 9 √ √
501109212 501129212 100 [212] 9 √ √
501109286 501129286 141 [286] 9 √ √
U=Upright Approved, √=Both Approved
71,4 mm
(2-13/16")

Finish Code: 1=Plain Brass, 6=Wax Coated, 7=Lead Coated, 8=Wax-Over Lead Coated, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–61
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Storage Sprinklers
ELO-231, K=161 (11.2), 1 ⁄ 2" NPT
Upright • K=161 [11.2] K=161 [11.2] • 1 ⁄ 2” NPT • TFP340
1
⁄ 2” NPT • SIN TY5811 Part No. Temp. Approvals & Listings
Finish
Upright

FM
°C °F Code

UL
SIN TY5811

502101165 74 [165] 1 √ √
71,4 mm 502101212 100 [212] 1 √ √
(2-13/16") 502101286 141 [286] 1 √ √
502106165 74 [1565] 6 √ √
502106212 100 [212] 6 √ √
502106286 141 [286] 6 √ √
502107165 74 [165] 7 √ √
502107212 100 [212] 7 √ √
502107286 141 [286] 7 √ √
502108165 74 [165] 8 √ √
502108212 100 [212] 8 √ √
502108286 141 [286] 8 √ √
502109165 74 [165] 9 √ √
502109212 100 [212] 9 √ √
502109286 141 [286] 9 √ √

Finish Code: 1=Plain Brass, 6=Wax Coated, 7=Lead Coated, 8=Wax-Over Lead Coated, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–62
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Storage Sprinklers
LD "Large Drop"
Upright, Control Mode Specific Application
K Factor K= 161 (11.2)
3
Thread Size ⁄4" NPT

Approvals UL, C-UL, NYC

Temperature 68°C (155°F), 93°C (200°F), 141°C (286°F)

Sprinkler Finish Natural Brass

SIN TY5153

Wrench Type W-TYPE 3

Tech Data Sheet TFP335

5 mm bulb • Control mode sprinkler • Can provide a higher level of protection than standard spray sprinklers • Can provide an
advantage by eliminating in-rack sprinklers • Designed for the protection of high-piled storage

LD “Large Drop”, K=161 (11.2), 3 ⁄4" NPT


Upright • K=161 [11.2]
3
⁄4” NPT • SIN TY5153 K=161 [11.2] • 3 ⁄4” NPT • TFP335
Part No. Temp. Approvals & Listings
Finish
Upright
°C °F Code

UL
SIN TY5153

60,3 mm 504002155 68 [155] 2 √


(2-3/8") 504002200 93 [200] 2 √
504002286 141 [286] 2 √

Finish Code: 2= Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–63
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Storage Sprinklers
TY-B
Pendent & Upright, Intermediate Level
K Factor K= 80 (5.6) • K= 115 (8.0)
1
Thread Size ⁄2" NPT • 3 ⁄4" NPT

Approvals UL, C-UL, FM, NYC

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F), 182°C (360°F)

Natural Brass, Lead Coated, Wax Coated, Wax over


Sprinkler Finish
Lead Coated

SIN TY3153, TY3251, TY4153, TY4251

Wrench Type W-TYPE 6

Tech Data Sheet TFP351

5 mm bulb • Intermediate level (in-rack) with shield • Used where sprinkler guards are not required • Upright factory assembled unit
having an integral water shield • Both the Pendent and Upright Sprinklers produce a hemispherical water distribution pattern below
the deflector.

TY-B, K=80 (5.6), 1 ⁄ 2" NPT

K=80 [5.6] • 1⁄ 2” NPT • TFP351


Upright • K=80 [5.6] Approvals
Part No. Temp.
1
⁄ 2” NPT • SIN TY3153 & Listings
Finish
Pendent *
Upright Pendent Code

FM
Shield &

UL
88,9 mm (3-1/2") °C °F
SIN TY3153 SIN TY3251
O-Ring
SHIELD
SCREW 575331135 575711135 57 135 1 √ √
575331155 575711155 68 155 1 √ √
575331175 575711175 79 175 1 √ √
560709332
575331200 575711200 93 200 1 √ √
575331286 575711286 141 286 1 √ √
UPRIGHT 575331360 575711360 182 360 1 √ √
60,3 mm SHIELD
- 575716135 57 135 6 P P
(2-3/8")
- 575716155 68 155 6 P P
- 575716175 560709332 79 175 6 P P
- 575716200 93 200 6 P P
- 575716286 141 286 6 P P
575337135 575717135 57 135 7 √ √
575337155 575717155 68 155 7 √ √
Pendent • K=80 [5.6] 575337175 575717175 79 175 7 √ √
560709332
1
⁄ 2” NPT • SIN TY3251 575337200 575717200 93 200 7 √ √
575337286 575717286 141 286 7 √ √
O-RING 575337360 575717360 182 360 7 √ √
- 575718135 57 135 8 P P
- 575718155 68 155 8 P P
- 575718175 560709332 79 175 8 P P
- 575718200 93 200 8 P P
55,6 mm
- 575718286 141 286 8 P P
MODEL S2 (2-3/16")
* Pendent Shield & O-Ring Ordered Separately
SHIELD
P=Pendent Approved, √=Both Approved

88,9 mm (3-1/2")

Finish Code: 1=Plain Brass, 6=Wax Coated, 7=Lead Coated, 8=Wax-Over Lead Coated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–64
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Storage Sprinklers
TY-B, K=115 (8.0), 3 ⁄4" NPT

K=115 [8.0] • 3 ⁄4” NPT • TFP351


Upright • K=115 [8.0] Approvals
Part No. Temp.
3
⁄4” NPT • SIN TY4153 & Listings
Finish
Pendent *
Upright Pendent Code

FM
88,9 mm (3-1/2") Shield &

UL
°C °F
SIN TY4153 SIN TY4251
SHIELD O-Ring
SCREW 575431135 575911135 57 135 1 √ √
575431155 575911155 68 155 1 √ √
575431175 575911175 79 175 1 √ √
560709342
UPRIGHT 575431200 575911200 93 200 1 √ √
61,9 mm SHIELD 575431286 575911286 141 286 1 √ √
575431360 575911360 182 360 1 √ √
(2-7/16")
- 575916135 57 135 6 P P
- 575916155 68 155 6 P P
- 575916175 560709342 79 175 6 P P
- 575916200 93 200 6 P P
- 575916286 141 286 6 P P
575437135 575917135 57 135 7 √ √
575437155 575917155 68 155 7 √ √
Pendent • K=115 [8.0] 575437175 575917175 79 175 7 √ √
3
⁄4” NPT • SIN TY4251 560709342
575437200 575917200 93 200 7 √ √
88,9 mm (3-1/2") 575437286 575917286 141 286 7 √ √
575437360 575917360 182 360 7 √ √
O-RING - 575918135 57 135 8 P P
- 575918155 68 155 8 P P
- 575918175 560709342 79 175 8 P P
- 575918200 93 200 8 P P
58,7 mm - 575918286 141 286 8 P P
MODEL S2 (2-5/16")
* Pendent Shield & O-Ring Ordered Separately
SHIELD

Finish Code: 1=Plain Brass, 6=Wax Coated, 7=Lead Coated, 8=Wax-Over Lead Coated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–65
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Storage Sprinklers
TY-B
Pendent & Upright, Intermediate Level
K Factor K= 80 (5.6)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, FM

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F), 182°C (360°F)

Sprinkler Finish Natural Brass

Guard Finish Red or Zinc

SIN TY315, TY325

Wrench Type W-TYPE 6

Tech Data Sheet TFP352, TFP780

5 mm bulb • Factory assembled unit having an integral water shield • Intermediate Level Sprinklers are primarily designed for use in
rack storage sprinkler systems where their thermally sensitive elements must be shielded from the water spray of higher elevation
sprinklers that could operate earlier during a fire • May also be used in other applications such as beneath open gridded catwalks.

TY-B, K=80 (5.6), 1 ⁄ 2" NPT

Upright • K=80 [5.6] K=80 [5.6] • 1⁄ 2” NPT • TFP352


1
⁄ 2” NPT • SIN TY315 Part No. Temp. Approvals & Listings
101,6 mm (4") Finish
Upright Pendent

FM

UL
°C °F Code
SIN TY315 SIN TY325

775701135 775711135 57 135 1 √ √


775701155 775711155 68 155 1 √ √
76,2 mm
(3") 775701175 775711175 79 175 1 √ √
775701200 775711200 93 200 1 √ √
775701286 775711286 141 286 1 √ √
775701360 775711360 182 360 1 √

73,0 mm
(2-7/8")
Pendent • K=80 [5.6]
1
⁄ 2” NPT • SIN TY325

88,9mm (3-1/2") Guards and Shields • TFP780


Part No. Approvals & Listings
Upright Pendent
Finish
FM

G1/S1 Guard G1 Guard, Shield


UL

& Shield & O-Ring


76,2 mm 569381066 569381001 Red Painted √ √
(3") 569389066 569389001 Zinc Chromate √ √

73,0 mm
(2-7/8")
88,9 mm (3-1/2")
Pendent Shields with O-Ring • TFP780
Part No. Approvals & Listings
Pendent
Finish
FM

50,8 mm S2 Shield
UL

(2") with O-Ring


560709332 Zinc Chromate √ √

Finish Code: 1=Plain Brass


Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–66
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Storage Sprinklers
TY-FRB
Pendent & Upright, Intermediate Level
K Factor K= 80 (5.6) • K= 115 (8.0)
1
Thread Size ⁄2" NPT • 3 ⁄4" NPT

Approvals UL, C-UL, FM, NYC

57°C (135°F), 68°C (155°F), 79°C (175°F),


Temperature
93°C (200°F), 141°C (286°F)

Sprinkler Finish Natural Brass, Lead Coated

SIN TY3133, TY3231, TY4133, TY4231

Wrench Type W-TYPE 6

Tech Data Sheet TFP356

3 mm bulb • Intermediate level with shield • Factory assembled unit having an integral water shield • Used where sprinkler guards
are not required

TY-FRB, K=80 (5.6), 1 ⁄ 2" NPT


K=80 [5.6] • 1⁄ 2” NPT • TFP356
Approvals
Part No. Temp.
& Listings
Upright • K=80 [5.6]
Finish
1
⁄ 2” NPT • SIN TY3133 Pendent *
Upright Pendent Code

FM
Shield &

UL
°C °F
88,9 mm (3-1/2") SIN TY3133 SIN TY3231
O-Ring
573331135 573711135 57 135 1 √ √
573331155 573711155 68 155 1 √ √
573331175 573711175 560709332 79 175 1 √ √
573331200 573711200 93 200 1 √ √
60,3 mm 573331286 573711286 141 286 1 √ √
(2-3/8") 573337135 573717135 57 135 7 U U
573337155 573717155 68 155 7 U U
573337175 573717175 560709332 79 175 7 U U
573337200 573717200 93 200 7 U U
573337286 573717286 141 286 7 U U
U=Upright Approved, √=Both Approved
Pendent • K=80 [5.6]
1
⁄ 2” NPT • SIN TY3231

88,9 mm (3-1/2")
O-RING

55,6 mm
MODEL S2 (2-3/16")
SHIELD

Finish Code: 1=Plain Brass, 7=Lead Coated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–67
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Storage Sprinklers

TY-FRB, K=115 (8.0), 3 ⁄4" NPT

K=115 [8.0] • 3 ⁄4” NPT • TFP356


Upright • K=115 [8.0]
3
⁄4” NPT • SIN TY4133 Approvals
Part No. Temp.
& Listings
Finish
88,9 mm (3-1/2") Pendent *
Upright Pendent Code

FM
Shield &

UL
°C °F
SIN TY4133 SIN TY4231
O-Ring
573431135 573911135 57 135 1 √ √
573431155 573911155 68 155 1 √ √
573431175 573911175 79 175 1 √ √
61,9 mm 560709342
573431200 573911200 93 200 1 √ √
(2-7/16") 573431286 573911286 141 286 1 √ √
573431360 573911360 182 360 1 √ √
573437135 573917135 57 135 7 U U
573437155 573917155 68 155 7 U U
573437175 573917175 79 175 7 U U
560709342
573437200 573917200 93 200 7 U U
573437286 573917286 141 286 7 U U
Pendent • K=115 [8.0]
3
⁄4” NPT • SIN TY4231 573437360 573917360 182 360 7 U U
U=Upright Approved, √=Both Approved
88,9 mm (3-1/2")

O-RING

58,7 mm
MODEL S2 (2-5/16")
SHIELD

Finish Code: 1=Plain Brass, 7=Lead Coated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–68
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Storage Sprinklers
TY-FRB
Pendent & Upright, Intermediate Level
K Factor K= 80 (5.6)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, FM

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F)

Sprinkler Finish Natural Brass

Guard Finish Red or Zinc

SIN TY313, TY323

Wrench Type W-TYPE 6

Tech Data Sheet TFP357, TFP780

3 mm bulb • Factory assembled unit having an integral water shield • Intermediate Level Sprinklers are primarily designed for use in
rack storage sprinkler systems where their thermally sensitive elements must be shielded from the water spray of higher elevation
sprinklers that could operate earlier during a fire • May also be used in other applications such as beneath open gridded catwalks

TY-FRB, K=80 (5.6), 1 ⁄ 2" NPT

Upright • K=80 [5.6] K=80 [5.6] • 1⁄ 2” NPT • TFP357


1
⁄ 2” NPT • SIN TY313
Part No. Temp. Approvals & Listings
101,6mm (4")
Finish
Upright Pendent

FM

UL
°C °F Code
SIN TY313 SIN TY323

773501135 773511135 57 135 1 √ √


76,2 mm 773501155 773511155 68 155 1 √ √
(3") 773501175 773511175 79 175 1 √ √
773501200 773511200 93 200 1 √ √
773501286 773511286 141 286 1 √ √
Use Suffix “I” for ISO 7-1 connection; for example, 773501286-I.
73,0 mm
(2-7/8")
Pendent • K=80 [5.6]
1
⁄ 2” NPT • SIN TY323
88,9mm (3-1/2")
Guards and Shields • TFP780
Part No. Approvals & Listings
Upright Pendent
Finish
FM

G1/S1 Guard G1 Guard, Shield


UL

& Shield & O-Ring


76,2 mm
(3") 569381066 569381001 Red Painted √ √
569389066 569389001 Zinc Chromate √ √

73,0 mm
(2-7/8")
88,9 mm
(3-1/2") Pendent Shields with O-Ring • TFP780
O-RING Approvals & Listings
Part No.
Pendent
Finish
FM

S2 Shield
UL

50,8 mm
(2") with O-Ring
MODEL S2 560709332 Zinc Chromate √ √
SHIELD
Finish Code: 1=Plain Brass
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–69
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Storage Sprinklers
TY-L
Pendent & Upright, Intermediate Level
K Factor K= 80 (5.6) • K= 115 (8.0)
1
Thread Size ⁄2" NPT • 3 ⁄4" NPT

Approvals UL, C-UL, FM

Temperature 74°C (165°F), 100°C (212°F), 138°C (280°F)

Sprinkler Finish Natural Brass

SIN TY3113, TY3211, TY4113, TY4211

Wrench Type W-TYPE 9

Tech Data Sheet TFP350

Solder type • Intermediate level with shield • Factory assembled unit having an integral water shield • Used where sprinkler guards
are not required

TY-L, K=80 (5.6), 1 ⁄ 2" NPT


K=80 [5.6] • 1 ⁄ 2” NPT • TFP350
Approvals &
Upright • K=80 [5.6] Part No. Temperature
1 Listings
⁄ 2” NPT • SIN TY3113
Finish
Pendent
76,2 mm (3") Upright Pendent Code

FM
Shield & °C °F

UL
SIN TY3113 SIN TY3211
O-Ring
532531165 511121165 74 [165] 1 √ √
532531212 511121212 560156802 100 [212] 1 √ √
532531280 511121280 138 [280] 1 √ √

2-11/16"
(68,3 mm)

Pendent • K=80 [5.6]


1
⁄ 2” NPT • SIN TY3211

76,2 mm (3")
O-RINGS

SHIELD 66,7 mm
(2-5/8")

Finish Code: 1=Plain Brass


Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–70
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Storage Sprinklers

TY-L, K=115 (8.0), 3 ⁄4" NPT


K=115 [8.0] • 3 ⁄4” NPT • TFP350
Upright • K=115 [8.0] Approvals
3
⁄4” NPT • SIN TY4113 Part No. Temp.
& Listings
76,2 mm (3") Finish
Pendent
Upright Pendent Code

FM
Shield &

UL
°C °F
SIN TY4113 SIN TY4211
O-Ring
531531135 511021135 74 165 1 √ √
531531286 511021286 560156803 100 212 1 √ √
531531360 511021360 138 280 1 √ √
69,9 mm
(2-3/4")

Pendent • K=115 [8.0]


3
⁄4” NPT • SIN TY4211

76,2 mm (3")

O-RINGS

SHIELD 68,3 mm
(2-11/16")

Finish Code: 1=Plain Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–71
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Storage Sprinklers
TY-FRL
Pendent & Upright, Intermediate Level
K Factor K= 80 (5.6) • K= 115 (8.0)
1
Thread Size ⁄2" NPT • 3 ⁄4" NPT

Approvals UL, C-UL, FM, NYC

Temperature 74°C (165°F)

Sprinkler Finish Natural Brass, Chrome Plated

SIN TY3123, TY3221, TY4123, TY4221

Wrench Type W-TYPE 9

Tech Data Sheet TFP355

Solder type • Intermediate level with shield • Factory assembled unit having an integral water shield • Used where sprinkler guards
are not required

TY-FRL, K=80 (5.6), 1 ⁄ 2" NPT

Upright • K=80 [5.6] K=80 [5.6] • 1 ⁄ 2” NPT • TFP355


1
⁄ 2” NPT • SIN TY3123 Approvals &
Part No. Temperature
Listings
104,8 mm (4-1/8") Finish
Pendent
Upright Pendent Code

FM
Shield & °C °F

UL
SIN TY3123 SIN TY3221
O-Ring
589861165 589821165 74 [165] 1 √ √
560156802
589869165 589829165 74 [165] 9 √ √

69,9 mm
(2-3/4")

Pendent • K=80 [5.6]


1
⁄ 2” NPT • SIN TY3221

104,8 mm (4-1/8")
O-RING

SHIELD
68,3 mm
(2-11/16")

Finish Code: 1=Plain Brass, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–72
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Storage Sprinklers

TY-FRL, K=115 (8.0), 3 ⁄4" NPT

K=115 [8.0] • 3 ⁄4” NPT • TFP355


Upright • K=115 [8.0] Approvals &
Part No. Temperature
3
⁄4” NPT • SIN TY4123 Listings
Finish
Pendent
104,8 mm (4-1/8") Upright Pendent Code

FM
Shield & °C °F

UL
SIN TY4123 SIN TY4221
O-Ring
581531165 581721165 74 [165] 1 √ √
560156802
581539165 581729165 74 [165] 9 √ √

71,4 mm
(2-13/16")

Pendent • K=115 [8.0]


3
⁄4” NPT • SIN TY4221

104,8 mm (4-1/8")

O-RING

SHIELD
74,6 mm
(2-15/16")

Finish Code: 1=Plain Brass, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–73
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Storage Sprinklers
Sprinkler Guards
Model G1 & G4 Sprinkler Guards
Model G1/S1 & G4/S3 Guards with Shields
Approvals UL, C-UL, FM

Plain Brass, Red Painted, Chrome Plated,


Guard Finishes
Zinc Chromate

Tech Data Sheet TFP780

Designed for use with specific types of Series TY-B, TY-FRB, TY-L, and TY-FRL Sprinklers that may be located in areas that
make them susceptible to mechanical or physical damage • Rugged guard design to minimise possible damage to sprinklers •
Shields are for use in storage racks or beneath grated mezzanine, or other areas requiring the sprinklers to be shielded from
possible discharge from sprinklers above • Can be used with either 1 ⁄ 2" or 3 ⁄4" NPT sprinklers

73,0mm (2-7/8")
G1 - Guards • TFP780
Part No. Approvals & Listings
Finish

FM
G1 Guard

UL
569381001 Red Painted √ √
58,7 mm
569389001 Zinc Chromate √ √
(2-5/16")

G1
101,6mm (4")

G1/S1 - Guards and Shields • TFP780


60,3 mm
(2-3/8") Part No. Approvals & Listings
G1/S1 Guard Finish

FM

UL
& Shield
569381001 Red Painted √ √
569389001 Zinc Chromate √ √
73,0 mm
G1/S1 (2-7/8")

73,0mm (2-7/8")

G4 - Guards • TFP780
Part No. Approvals & Listings
Finish
FM

G4 Guard
UL

87,3 mm
(3-7/16")
569371001 Red Painted √ √
569379001 Zinc Chromate √ √

G4
120,7mm (4-3/4")

G4/S3 - Guards and Shields • TFP780


Part No. Approvals & Listings
88,9 mm
G4/S3 Guard Finish
FM

(3-1/2")
UL

& Shield
569371066 Red Painted √ √
569379066 Zinc Chromate √ √

G4/S3 with Shield


73,0mm (2-7/8")
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–74
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Storage Sprinklers
Sprinkler Guards
Model G2 Sprinkler Guard, Model WS-2 Shield, and
Model WSG-2 Sprinkler Guard with Shield
Approvals UL, C-UL, FM

Guard Finishes Red Painted, Zinc Coated

Tech Data Sheet TFP780

Designed for use with Series ELO-231, ELO-231B, or ELO-231FRB Sprinklers that may be located in areas that make them
susceptible to mechanical or physical damage • Rugged guard design to minimise possible damage to sprinklers • Shields are
for use in storage racks or beneath grated mezzanine, or other areas requiring the sprinklers to be shielded from possible
discharge from sprinklers above • Can be used with either 1 ⁄ 2" or 3 ⁄4" NPT sprinklers

G2 - Guards • TFP780
76,2 mm Part No. Approvals & Listings
(3") Finish

FM
G2 Guard

UL
560001087 Red Painted √ √
560001086 Zinc Coated √ √

G2 82,6 mm
(3-1/4")

127,0 mm
WS-2 - Shields • TFP780
(5")
Approvals &
Part No.
Thread Listings
Finish
Size
WS-2 Shield UL
1
560001081 ⁄ 2" NPT Red √
560001083 3
⁄4" NPT Painted √
1
560001080 ⁄ 2" NPT Zinc √
560001082 3
⁄4" NPT Coated √
WS-2 Shield

127,0 mm
(5")

WSG-2 - Guards & Shields • TFP780


79,4 mm Part No. Approvals & Listings
(3-1/8")
WSG-2 Guard Finish
UL

& Shield
560001098 Red Painted √
560001097 Zinc Coated √
WSG-2 with Shield

82,6 mm
(3-1/4")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–75
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Storage Sprinklers
Sprinkler Guards
Model EG-25 Sprinkler Guard
for Model ESFR-25 Pendent Sprinkler
Approvals FM

Guard Finishes Red Painted, Zinc Chromate

Tech Data Sheet TFP784

Designed for use with the TYCO Model ESFR-25 Pendent Sprinkler and may be located in areas that make it susceptible to
mechanical or physical damage • Provides protection from mechanical and/or physical damage, for example, rack storage
sprinkler installations • Welded assembly fabricated from carbon steel

92 mm
(3-5/8")

EG-25 - Guards • TFP784


Part No. Approvals & Listings
Finish

FM
EG-25 Guard

569391025 Red Painted √


569399025 Zinc Chromate √

103 mm
(4")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–76
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Storage Sprinklers
Sprinkler Guards
Model GUMC/GUWSU Sprinkler Guard
for use with Series TY-B/TY-FRB Sprinklers Only
Approvals FM

Guard Finishes Zinc Chromate

Tech Data Sheet TFP781

Designed for use with Series TY-B and TY-FRB sprinklers and may be located in areas that make it susceptible to mechanical
or physical damage • Installation of Guards on Sprinklers form Intermediate Level Sprinkler assemblies intended for use in fire
sprinkler systems. • Welded assembly fabricated from carbon steel

58 mm
(2-1/4")
GUMC - Guards • TFP781
Part No.
Thread
Finish
GUMC Guards Size

58 mm GUMC15 15mm (1 ⁄ 2") Zinc


(2-1/4") GUMC20-1 20mm (3 ⁄4") Chromate

95 mm
(3-3/4")
GUWSU - Guards & Shields • TFP781
Part No.
Thread
GUWSU - Guards Finish
59 mm Size
& Shields
(2-5/16")
GUWSU15 15mm (1 ⁄ 2") Zinc
GUWSU20-1 20mm (3 ⁄4") Chromate

58 mm
(2-1/4")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–77
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Storage Sprinklers
Sprinkler Guards
Type 011 Sprinkler Guard
for use with Series TY-B & TY-FRB Sprinklers
Approvals FM

Guard Finishes Red Painted, Zinc Chromate

Tech Data Sheet TFP781

Designed for use with Series TY-B and TY-FRB sprinklers and may be located in areas that make it susceptible to mechanical
or physical damage • Installation of Guards on Sprinklers form Intermediate Level Sprinkler assemblies intended for use in fire
sprinkler systems. • Welded assembly fabricated from carbon steel

Type 011 - Guards


Part No.
85 mm Type 011 Finish
(3-3/8") Guards
0110000 Red Painted
0110100 Zinc Chromate

Guard 2-Screw - Guards • TFP781


Part No.
Guard 2-Screw Height Finish
Guard
55 55mm (2-3 ⁄ 16") Zinc
77 77mm (3") Chromate

Guard 2-Screw - Guards & Shields • TFP781


Part No.
Guard 2-Screw - Diameter Height Finish
Guard & Shield
55-B-160 160 (6-1/3") 55mm (2-3 ⁄ 16") Zinc
77-B-150 150 (6") 77mm (3") Chromate

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–78
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
RAPID RESPONSE® Residential Sprinkler Systems
Offer optimum design and flow characteristics for all residential applications.
- Townhomes - Assisted Living

- Multi-family - Student Housing

- Single-family - Beam and sloped ceilings

- Hotel / motel

Custom paint options available


We offer custom paint cover plates for sprinklers with this icon.
Learn more at www.tyco-fire.com/custompaint.

www.tyco-fire.com 1–79
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Rapid Response® Sprinklers


LFII
Pendent & Recessed Pendent
K Factor K= 70 (4.9)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, NSF/ANSI 61

Temperature 68°C (155°F), 79°C (175°F)

Escutcheon Style 20

Pure White, Signal White, Chrome Plated,


Sprinkler Finish
Natural Brass

SIN TY2236

Wrench Type W-TYPE 6, W-Type 7 (For recessed escutcheons)

Tech Data Sheet TFP403

3 mm bulb type • Approved for special applications with beamed ceilings


Intended for use in wet & dry pipe scenarios:
- residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D
- residential occupancies up to and including four stories in height per NFPA 13R
- sprinkler systems for the residential portions of any occupancy per NFPA 13

LFII, K=70 (4.9), 1 ⁄ 2" NPT


K=70 [4.9] • 1 ⁄ 2” NPT • TFP403
Pendent • K=70 [4.9] Part No. Temp. Approvals & Listings
1
⁄ 2” NPT • SIN TY2236

NSF/ANSI61
Finish
Pendent
°C °F Code

UL
SIN TY2236

512121155 68 [155] 1 √ √
57,2 mm 512121175 79 [175] 1 √ √
(2-1/4") 512123155 68 [155] 3 √ √
512123175 79 [175] 3 √ √
512124155 68 [155] 4 √ √
512124175 79 [175] 4 √ √
512125155 68 [155] 5 √ √
512125175 79 [175] 5 √ √
512129155 68 [155] 9 √ √
512129175 79 [175] 9 √ √

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 5=Jet Black Polyester RAL9005, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–80
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Rapid Response® Sprinklers
LFII
Pendent & Recessed Pendent
K Factor K= 83 (5.8)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, NSF/ANSI 61

Temperature 68°C (155°F), 79°C (175°F)

Escutcheon Style 20

Signal White, Pure White, Chrome Plated,


Sprinkler Finish
Natural Brass, Jet Black

SIN TY3934

Wrench Type W-TYPE 6, W-Type 7 (For recessed escutcheons)

Tech Data Sheet TFP401

3 mm bulb type
Intended for use in these wet pipe scenarios:
- residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D
- residential occupancies up to and including four stories in height per NFPA 13R
- sprinkler systems for the residential portions of any occupancy per NFPA 13

LFII, K=83 (5.8), 1 ⁄ 2" NPT


K=83 [5.8] • 1 ⁄ 2” NPT • TFP401
Pendent • K=83 [5.8] Part No. Temp. Approvals & Listings
1
⁄ 2” NPT • SIN TY3934

NSF/ANSI61
Finish
Pendent
°C °F Code
UL
SIN TY3934

510581155 68 [155] 1 √ √
50,8 mm
(2") 510581175 79 [175] 1 √ √
510583155 68 [155] 3 √ √
510583175 79 [175] 3 √ √
510584155 68 [155] 4 √ √
510584175 79 [175] 4 √ √
510585155 68 [155] 5 √ √
510585175 79 [175] 5 √ √
510589155 68 [155] 9 √ √
510589175 79 [175] 9 √ √

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 5=Jet Black Polyester RAL9005, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–81
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Rapid Response® Sprinklers


LFII
Pendent & Recessed Pendent
K Factor K= 43 (3.0)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, NSF/ANSI 61

Temperature 68°C (155°F), 79°C (175°F)

Escutcheon Style 20

Sprinkler Finish Signal White, Chrome Plated, Natural Brass

SIN TY1234

Wrench Type W-TYPE 6, W-Type 7 (For recessed escutcheons)

Tech Data Sheet TFP402

3 mm bulb type • Decorative, fast response, frangible bulb sprinklers designed for use in residential occupancies such as homes,
apartments, dormitories, and hotels.
Intended for use in these wet pipe scenarios:
- residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D
- residential occupancies up to and including four stories in height per NFPA 13R
- sprinkler systems for the residential portions of any occupancy per NFPA 13

LFII, K=43 (3.0), 1 ⁄ 2" NPT


K=43 [3.0] • 1 ⁄ 2” NPT • TFP402
Pendent • K=43 [3.0] Part No. Temp. Approvals & Listings
1
⁄ 2” NPT • SIN TY1234

NSF/ANSI61
Finish
Pendent
°C °F Code
SIN TY1234 UL

55,6 mm 510101155 68 [155] 1 √ √


(2-3/16") 510101175 79 [175] 1 √ √
510104155 68 [155] 4 √ √
510104175 79 [175] 4 √ √
510109155 68 [155] 9 √ √
510109175 79 [175] 9 √ √

Finish Code: 1=Plain Brass, 4=Signal White Polyester RAL9003, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–82
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Rapid Response® Sprinklers
LFII
Horizontal & Recessed Horizontal Sidewall
K Factor K= 63 (4.4)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, NSF/ANSI 61

Temperature 68°C (155°F), 79°C (175°F)

Escutcheon Style 20

Sprinkler Finish Signal White, Chrome Plated, Natural Brass

SIN TY2334

Wrench Type W-TYPE 6, W-Type 7 (For recessed escutcheons)

Tech Data Sheet TFP412

3 mm bulb type
Intended for use in these wet pipe scenarios:
- residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D
- residential occupancies up to and including four stories in height per NFPA 13R
- sprinkler systems for the residential portions of any occupancy per NFPA 13

LFII, K=63 (4.4), 1 ⁄ 2" NPT


K=63 [4.4] • 1 ⁄ 2” NPT • TFP412
Horizontal Sidewall • K=63 [4.4] Part No. Temp. Approvals & Listings
1
⁄ 2” NPT • SIN TY2334

NSF/ANSI61
Finish
HSW
°C °F Code

UL
SIN TY2334

512151155 68 [155] 1 √ √
512151175 79 [175] 1 √ √
54,0 mm 512154155 68 [155] 4 √ √
(2-1/8")
512154175 79 [175] 4 √ √
512159155 68 [155] 9 √ √
512159175 79 [175] 9 √ √

Finish Code: 1=Plain Brass, 4=Signal White Polyester RAL9003, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–83
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Rapid Response® Sprinklers


LFII
Horizontal & Recessed Horizontal Sidewall
K Factor K= 60 (4.2)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, NYC, NSF/ANSI 61

Temperature 68°C (155°F), 79°C (175°F)

Escutcheon Style 20

Pure White, Signal White, Chrome Plated,


Sprinkler Finish
Natural Brass

SIN TY1334

Wrench Type W-TYPE 6, W-Type 7 (For recessed escutcheons)

Tech Data Sheet TFP410

3 mm bulb type • Approved for special applications with beamed ceilings


Intended for use in the following scenarios:
- wet and dry pipe residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D
- wet and dry pipe residential occupancies up to and including four stories in height per NFPA 13R
- wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

LFII, K=60 (4.2), 1 ⁄ 2" NPT


K=60 [4.2] • 1 ⁄ 2” NPT • TFP410
Horizontal Sidewall • K=60 [4.2] Part No. Temp. Approvals & Listings
1
⁄ 2” NPT • SIN TY1334

NSF/ANSI61
Finish
HSW
°C °F Code
UL
SIN TY1334

512111155 68 [155] 1 √ √
512111175 79 [175] 1 √ √
512113155 68 [155] 3 √ √
57,2 mm
512113175 79 [175] 3 √ √
(2-1/4")
512114155 68 [155] 4 √ √
512114175 79 [175] 4 √ √
512119155 68 [155] 9 √ √
512119175 79 [175] 9 √ √

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–84
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Rapid Response® Sprinklers
LFII
Flat Plate Concealed Pendent
K Factor K= 70 (4.9)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, NYC, NSF/ANSI 61

71°C (160°F) - Sprinkler, 59°C (139°F) - Cover Plate


Temperature
100°C (212°F) - Sprinkler, 74°C (165°F) - Cover Plate

Ivory, Beige, Pure White, Signal White, Grey White,


Cover Plate Finish Brown, Black, Brushed Brass, Brushed Chrome,
Custom Paint

SIN TY3596

Wrench Type W-TYPE 18

Tech Data Sheet TFP442

Solder type • Provides 12,7 mm (1 ⁄ 2") vertical adjustment. This adjustment provides flexibility when cutting fixed sprinkler drops
• Cover plate conceals sprinkler components above the ceiling
Intended for use in the following scenarios:
- wet and dry pipe residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D
- wet and dry pipe residential occupancies up to and including four stories in height per NFPA 13R
- wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

LFII, K=70 (4.9), 1 ⁄ 2" NPT K=70 [4.9] • 1 ⁄ 2” NPT • TFP442


Part No. Temp. Approvals & Listings
Concealed Pendent • K=70 [4.9]
1
⁄ 2” NPT • SIN TY3596

NSF/ANSI61
Finish
Pendent
°C °F Code

UL
SIN TY3596

511121160 71 160 1 √ √
511121212 100 212 1 √ √

52,4 mm Cover Plate


±6,4 mm Part No. Temp. For use with
(2-1/16"±1/4") Cover Plate
Cover Sprinkler Finish
°C °F
Plate Temp.
562040135 59 139 71°C, 160°F
Ivory (RAL1015)
562040165 74 165 100°C, 212°F
562042135 59 139 71°C, 160°F
Beige (RAL1001)
562042165 74 165 100°C, 212°F
81,0 mm 562043135 59 139 71°C, 160°F
Pure White (RAL9010)
(3-3/16") 562043165 74 165 100°C, 212°F
562044135 59 139 71°C, 160°F
Signal White (RAL9003)
562044165 74 165 100°C, 212°F
562045135 59 139 71°C, 160°F
Grey White (RAL9002)
562045165 74 165 100°C, 212°F
562046135 59 139 71°C, 160°F
Brown (RAL8028)
562046165 74 165 100°C, 212°F
562047135 59 139 71°C, 160°F
Black (RAL9005)
562047165 74 165 100°C, 212°F
562048135 59 139 71°C, 160°F
Brushed Brass
562048165 74 165 100°C, 212°F
562049135 59 139 71°C, 160°F
Brushed Chrome
562049165 74 165 100°C, 212°F
562041135 59 139 71°C, 160°F
Brass
562041165 74 165 100°C, 212°F
56204X135 59 139 71°C, 160°F
Finish Code: 1=Plain Brass Custom Paint
56204X165 74 165 100°C, 212°F
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–85
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Rapid Response® Sprinklers


LFII
Domed Plate Concealed Pendent
K Factor K= 70 (4.9)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, NYC

Temperature 68°C (155°F) - Sprinkler, 59°C (139°F) - Cover Plate

Cover Plate Finish Pure White, Signal White, Chrome, Custom

SIN TY2234

Wrench Type W-TYPE 7

Tech Data Sheet TFP450

3 mm bulb type • Can be used for horizontal and sloped ceilings • Cover plate conceals sprinkler components above the ceiling
Intended for use in the following scenarios:
- wet and dry pipe residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D
- wet and dry pipe residential occupancies up to and including four stories in height per NFPA 13R
- wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

LFII, K=70 (4.9), 1 ⁄ 2" NPT K=70 [4.9] • 1 ⁄ 2” NPT • TFP450


Part No. Temp. Approvals & Listings
Concealed Pendent • K=70 [4.9] Finish
1
⁄ 2” NPT • SIN TY2234 SIN TY2234

UL
°C °F Code

518731155 68 [155] 1 √

30,2 mm
±6,4 mm Cover Plate
(1-3/16"±1/4") Part No. Temp. For use with
Cover Plate
Cover Sprinkler Finish
°C °F
23,8 mm Plate Temp.
(15/16") 568733135 59 139 68°C, 155°F Pure White (RAL9010)
568734135 59 139 68°C, 155°F Signal White (RAL9003)
84,1 mm 568739135 59 139 68°C, 155°F Chrome
(3-5/16") 56873X135 59 139 68°C, 155°F Custom Paint

Finish Code: 1=Plain Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–86
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Rapid Response® Sprinklers
LFII
Concealed Horizontal Sidewall
K Factor K= 60 (4.2)

Thread Size 1⁄2" NPT

Approvals UL, C-UL, NSF/ANSI 61

Temperature 71°C (160°F) - Sprinkler, 59°C (139°F) - Cover Plate

Ivory, Beige, Pure White, Signal White, Grey White,


Cover Plate Finish Brown, Black, Brushed Brass, Brushed Chrome,
Custom

SIN TY2324

Wrench Type W-TYPE 37

Tech Data Sheet TFP445

Solder type • Can be used for horizontal and sloped ceilings • Cover plate conceals sprinkler components above the ceiling
Intended for use in the following scenarios:
- wet and dry pipe residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D
- wet and dry pipe residential occupancies up to and including four stories in height per NFPA 13R
- wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

LFII, K=60 (4.2), 1 ⁄ 2" NPT K=60 [4.2] • 1 ⁄ 2” NPT • TFP445


Part No. Temp. Approvals & Listings
Concealed HSW • K=60,5 [4.2]

NSF/ANSI61
1
⁄ 2” NPT • SIN TY2324 Finish
HSW

C-UL
°C °F Code

UL
SIN TY2324
39,7 mm ± 3,2 mm
(1-9/16" ± 1/8") 505201160 71 160 1 √ √ √
4,8 mm (3/16")
6,4 mm (1/4") Cover Plate
Adjustment
Part No. Temp. For use with
Cover Plate
Cover Sprinkler Finish
°C °F
Plate Temp.
562040135 59 139 71°C, 160°F Ivory (RAL1015)
562042135 59 139 71°C, 160°F Beige (RAL1001)
562043135 59 139 71°C, 160°F Pure White (RAL9010)
81,0 mm 562044135 59 139 71°C, 160°F Signal White (RAL9003)
(3-3/16" DIA.) 562045135 59 139 71°C, 160°F Grey White (RAL9002)
562046135 59 139 71°C, 160°F Brown (RAL8028)
562047135 59 139 71°C, 160°F Black (RAL9005)
562048135 59 139 71°C, 160°F Brushed Brass
562049135 59 139 71°C, 160°F Brushed Chrome
56204X135 59 139 71°C, 160°F Custom Paint

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–87
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Rapid Response® Sprinklers


LFII
Cover Plate & Protective Cap Utility Tool for Concealed Sprinklers

Used with the


TY2524, TY3531, TY3532, TY3551, TY3596
following Sprinklers

Contact Customer Service for details:


Tech Data Sheet
[email protected]

Install and remove cover plates for LFII, RFII, and RFIII concealed sprinklers • Also used for removing protective caps before cover
plate installation

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–88
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Rapid Response® Sprinklers
LFII
Dry Type Recessed Pendent
K Factor K= 70 (4.9)

Thread Size 1" NPT or ISO 7-R1

Approvals UL, NSF/ANSI 61

68°C (155°F)
Temperature
79°C (175°F) (wet pipe only)

Escutcheon Finish Signal White, Chrome Plated, Natural Brass

Sprinkler Finish Signal White, Chrome Plated, Natural Brass

SIN TY2235

Wrench Type W-TYPE 7

Tech Data Sheet TFP460

3 mm bulb type • Where sprinklers are required on dry pipe systems that are exposed to freezing temperatures, or where sprinklers
are seasonally drained to avoid freezing • Offer the features of non-water filled pipe in addition to not having to increase the
number of design sprinklers (hydraulic design area) for systems designed to NFPA 13, 13D, or 13R
Intended for use in the following residential sprinkler systems scenarios:
- one/two-family dwellings and mobile homes per NFPA 13D
- residential occupancies up to and including four stories in height per NFPA 13R
- the residential portions of any occupancy per NFPA 13

P/N* 63 — XXX — X — XXX

TEMPERATURE SPRINKLER ESCUTCHEON ORDER LENGTH


SIN RATING FINISH FINISH (EXAMPLES)
PENDENT 1 155°F (68°C) 055 5.50 in.
NATURAL BRASS
10 WITH RECESSED TY2235 2
BRASS PLATED
ESCUTCHEON
2 175°F (79°C)** 082 8.25 in.
SIGNAL WHITE SIGNAL WHITE
4 (RAL9003) (RAL9003)
POLYESTER POLYESTER 180 18.00 in.

CHROME CHROME 187 18.75 in.


9 PLATED PLATED
Notes:
* 240 24.00 in.
** Wet pipe system only

Order Lengths:
95,3 to 609,6 mm
(3-3/4" to 24")
IN 6,4 mm (1/4")
Increments

73,0 mm 34,9 ± 3,2 mm


Finish Code: 1=Plain Brass
(2-7/8") (1-3/8" ± 1/8")
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–89
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Rapid Response® Sprinklers


LFII
Dry Type Recessed Horizontal Sidewall
K Factor K= 63 (4.4)

Thread Size 1" NPT or ISO 7-R1

Approvals UL, NSF/ANSI 61

Temperature 68°C (155°F)

Escutcheon Finish Signal White, Chrome Plated, Natural Brass

Sprinkler Finish Signal White, Chrome Plated, Natural Brass

SIN TY2335

Wrench Type W-TYPE 6, W-Type 7 (For recessed escutcheons)

Tech Data Sheet TFP461

3 mm bulb type • The Series LFII Dry Type Residential Horizontal Sidewall Sprinklers are typically used where sprinklers and/or a
portion of the connecting piping are exposed to freezing temperatures • Offer the features of non-water filled pipe in addition to
not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13, 13D, or 13R
Intended for use in the following residential sprinkler systems scenarios:
- one/two-family dwellings and mobile homes per NFPA 13D
- residential occupancies up to and including four stories in height per NFPA 13R
- the residential portions of any occupancy per NFPA 13

P/N* 63 — XXX — X — XXX

TEMPERATURE SPRINKLER ESCUTCHEON ORDER LENGTH


SIN RATING FINISH FINISH (EXAMPLES)
HORIZONTAL 1 155°F (68°C) NATURAL BRASS 055 5.50 in.
SIDEWALL WITH 2
12 TY2335 BRASS PLATED
RECESSED
ESCUTCHEON 082 8.25 in.
SIGNAL WHITE SIGNAL WHITE
HORIZONTAL 4 (RAL9003) (RAL9003)
SIDEWALL POLYESTER POLYESTER 180 18.00 in.
13 TY2335
WITHOUT
ESCUTCHEON CHROME CHROME
9 187 18.75 in.
PLATED PLATED
Notes:
* 240 24.00 in.

Order Lengths:
139,7 to 609,6 mm (5-1/2" to 24")
In 6,4 mm (1/4") Increments

Order Lengths:
95,3 to 609,6 mm (3-3/4" to 24") 55,6 mm
In 6,4 mm (1/4") Increments (2-3/16")

73,0 mm
(2-7/8")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–90
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Rapid Response® Sprinklers

LFII • NFPA 13 Optimised Sprinklers


The large orifice K=99 (6.9), K=83 (5.8), and K=80 (5.6) sprinklers are primarily intended for residential use where there is a 0.1 gpm/sq. ft.
density NFPA 13 design requirement, and are generally used for installations in excess of four stories. They are optimised for residential
applications where this higher water-flow demand is required, and can meet those requirements with less pressure and smaller pipe sizes.
Pendent, Recessed Pendent & Domed Concealed
K Factor K= 99 (6.9)
3
Thread Size ⁄4" NPT

Approvals UL, C-UL, FM, NYC, NSF/ANSI 61

Temperature 68°C (155°F), 79°C (175°F), 59°C (139°F) - Cover Plate

Escutcheon Style 30

Escutcheon & Natural Brass, Chrome Plated,


Sprinkler Finish Pure White, Signal White

Cover Plate Finish Pure White, Signal White, Chrome, Custom

SIN TY4234

Wrench Type W-TYPE 6, W-Type 7 (For recessed escutcheons)

Tech Data Sheet TFP408

3 mm bulb type
Intended for use in the following scenarios:
- wet pipe residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D
- wet pipe residential occupancies up to and including four stories in height per NFPA 13R
- wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

LFII, K=99 (6.9), 3 ⁄4" NPT K=99 [6.9] • 3 ⁄4” NPT • TFP408
Approvals &
Pendent • K=99 [6.9] Part No. Temp.
Listings
3
⁄4” NPT • SIN TY4234 Finish

ANSI61
Pendent Code

NSF/
FM

°C °F
SIN TY4234 UL

510691155 68 [155] 1 √ √ √
510691175 79 [175] 1 √ √ √
57,2 mm 510693155 68 [155] 3 √ √ √
(2-1/4") 510693175 79 [175] 3 √ √ √
510694155 68 [155] 4 √ √ √
510694175 79 [175] 4 √ √ √
510699155 68 [155] 9 √ √ √
510699175 79 [175] 9 √ √ √

K=99 [6.9] • 3 ⁄4” NPT • TFP408


Concealed Pendent • K=99,4 [6.9] Part No. Temp. Approvals & Listings
3 Finish
⁄4” NPT • SIN TY4234 Concealed Pendent
UL

°C °F Code
Sprinkler Assembly
510681155 68 [155] 1 √
510681175 79 [175] 1 √
28,6 mm
Cover Plate
(1-1/8")
±6,4 mm Part No. Temp. For use with
Cover Plate
(1/4") Cover Sprinkler Finish
°C °F
Plate Temp.
25,4 mm 568733135 59 139 68°C, 155°F Pure White (RAL9010)
(1") 568734135 59 139 68°C, 155°F Signal White (RAL9003)
568739135 59 139 68°C, 155°F Chrome
84,1 mm
56873X135 59 139 68°C, 155°F Custom Paint
(3-5/16")
Finish Code: 1=Plain Brass,3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–91
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Rapid Response® Sprinklers

LFII • NFPA 13 Optimised Sprinklers


The large orifice K=99 (6.9), K=83 (5.8), and K=80 (5.6) sprinklers are primarily intended for residential use where there is a 0.1 gpm/sq. ft.
density NFPA 13 design requirement, and are generally used for installations in excess of four stories. They are optimised for residential
applications where this higher water-flow demand is required, and can meet those requirements with less pressure and smaller pipe sizes.

Horizontal & Recessed Horizontal Sidewall Sprinklers


K Factor K= 83 (5.8)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, FM, NSF/ANSI 61

Temperature 68°C (155°F), 79°C (175°F)

Escutcheon Style 20

Sprinkler Finish Signal White, Chrome Plated, Natural Brass

SIN TY4334

Wrench Type W-TYPE 6, W-Type 7 (For recessed escutcheons)

Tech Data Sheet TFP417

3 mm bulb type • Can be used for horizontal and sloped ceilings


Intended for use in the following scenarios:
- wet pipe residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D
- wet pipe residential occupancies up to and including four stories in height per NFPA 13R
- wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

LFII, K=83 (5.8), 1 ⁄ 2" NPT K=83 [5.8] • 1 ⁄ 2” NPT • TFP417


Part No. Temp. Approvals & Listings
Horizontal Sidewall • K=83 [5.8]
Finish

ANSI61
1
⁄ 2” NPT • SIN TY4334 HSW

NSF/
FM

°C °F Code
SIN TY4334 UL

515341155 68 [155] 1 √ √ √
515341175 79 [175] 1 √ √ √
515344155 68 [155] 4 √ √ √
515344175 79 [175] 4 √ √ √
57,2 mm
515349155 68 [155] 9 √ √ √
(2-1/4")
515349175 79 [175] 9 √ √ √

Finish Code: 1=Plain Brass, 4=Signal White Polyester RAL9003, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–92
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Rapid Response® Sprinklers

LFII • NFPA 13 Optimised Sprinklers


The large orifice K=99 (6.9), K=83 (5.8), and K=80 (5.6) sprinklers are primarily intended for residential use where there is a 0.1 gpm/sq. ft.
density NFPA 13 design requirement, and are generally used for installations in excess of four stories. They are optimised for residential
applications where this higher water-flow demand is required, and can meet those requirements with less pressure and smaller pipe sizes.
Horizontal & Recessed Horizontal Sidewall Sprinklers
K Factor K= 80 (5.6)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, NSF/ANSI 61

Temperature 68°C (155°F), 79°C (175°F)

Escutcheon Style 20

Natural Brass, Chrome Plated, Pure White,


Sprinkler Finish
Signal White

SIN T Y3334

Wrench Type W-TYPE 6, W-Type 7 (For recessed escutcheons)

Tech Data Sheet TFP415

3 mm bulb type • Can be used for horizontal and sloped ceilings


Intended for use in the following scenarios:
- wet pipe residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D
- wet pipe residential occupancies up to and including four stories in height per NFPA 13R
- wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13

LFII, K=80 (5.6), 1 ⁄ 2" NPT K=80 [5.6] • 1 ⁄ 2” NPT • TFP415


Approvals &
Horizontal Sidewall • K=80 [5.6] Part No. Temp.
Listings
1
⁄ 2” NPT • SIN TY3334

NSF/ANSI61
Finish
HSW Code
°C °F UL
SIN TY3334

515241155 68 [155] 1 √ √
515241175 79 [175] 1 √ √
57,2 mm 515243155 68 [155] 3 √ √
(2-1/4") 515243175 79 [175] 3 √ √
515244155 68 [155] 4 √ √
515244175 79 [175] 4 √ √
515249155 68 [155] 9 √ √
515249175 79 [175] 9 √ √

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–93
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Rapid Response® Sprinklers


RCP-1
Residential Control Panel

Size Range DN25 or DN40 (1" or 1-1 ⁄ 2")

Approvals UL Listed

Maximum Water
20,7 bar (300 psi)
Pressure

Air Pressure 0,7 bar (10 psi) to 4,5 bar (65 psi)

System For use in residential dry pipe fire protection systems

Tech Data Sheet TFP480

Model RCP-1 Residential Control Panel is an integrated valve manifold, air pressure, and electronic control package for controlling
the release of water into residential dry pipe sprinkler systems • Pre-wired assembly containing pre-programmed control panel,
system performance gauges, and an enclosed compressor • Supervised system valve system • Pre-engineered riser design • 48-
hour battery backup

200 mm (8") 355 mm (14")

45 mm
73 mm (2-7/8")
(1-3/4")
RCP-1 • TFP480
127 mm BACKUP ELECTRONIC
(5") BATTERIES CONTROL OPERATOR Approvals &
INTERFACE
Listings
Part No. System Size
AIR

UL
PRESSURE
CONTROL
DISCONNECT 523102601 1" √
"ON/OFF"
SWITCH 523102602 1-1 ⁄ 2" √

OUTLET
CONNECTION
TO DRY PIPE FIRE
PROTECTION
SYSTEM

SYSTEM
AIR SUPPLY
PRESSURE
GAUGE

1270 mm SYSTEM
(50") WATER SUPPLY
PRESSURE
GAUGE

MANIFOLD
ASSEMBLY

AIR
PRESSURE
CONTROL

ENCLOSURE
(PANEL DOOR
NOT SHOWN)
LEFT SIDE FRONT
SYSTEM SYSTEM
WATER SUPPLY * DRAIN
CONNECTION CONNECTION

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–94
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry Sprinklers
Specifically designed for areas where sprinklers may be subjected to freezing conditions.

- Unheated Warehouses - Covered Exterior Platforms

- Loading Docks

www.tyco-fire.com 1–95
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry Sprinklers
DS-1
Pendent, Upright & Horizontal Sidewall
K Factor K= 80 (5.6)

Thread Size 1" NPT (Standard Order), ISO 7-R1


Upright & HSW = UL, C-UL, FM, NYC, CE,
Fire Academy of Russia, LPCB
Approvals
Pendent = UL, C-UL,CE, FM, NYC, LPCB,
Fire Academy of Russia, VdS
57°C (135°F), 68°C (155°F), 79°C (175°F),
Temperature
93°C (200°F), 141°C (286°F), 182°C (360°F)

Escutcheon Finish Signal White, Chrome Plated, Brass Plated

Sprinkler Finish Natural Brass, Chrome Plated, Signal White

SIN TY3255, TY3155, TY3355

Wrench Type W-Type 7

Tech Data Sheet TFP500

Standard coverage • All hazards (light hazards, horizontal sidewall) • 5 mm bulb • Lengths up to 1220 mm (48") • Designed for use in
applications where sprinklers and/or connecting piping may be exposed to freezing conditions, or the sprinkler system is seasonally
drained • Special assembly provides a seal at the main pipe to prevent water from entering the assembly until the sprinkler
operates • Designed for use in applications requiring dry sprinklers, or where building construction or aesthetic considerations
make the installation of dry horizontal sidewall sprinklers more desirable than the dry pendent type

P/N* 60 – XXX – X – XXX

SPRINKLER ESCUTCHEON
SIN FINISH FINISH(1)
Pendent with TY3255 SIGNAL WHITE
96 CHROME
Standard Escutcheon (1 in. NPT) (Figure 3) 0 (RAL9003)
PLATED POLYESTER
Pendent with TY3255
93 Deep Escutcheon (1 in. NPT) (Figure 5) SIGNAL WHITE
NATURAL
1 (RAL9003)
Pendent with TY3255 BRASS
97 POLYESTER
Recessed Escutcheon (1 in. NPT) (Figure 4)
Pendent without TY3255 NATURAL BRASS
92 2
Escutcheon (1 in. NPT) (Figure 6) BRASS PLATED

SIGNAL WHITE SIGNAL WHITE


Sidewall with TY3355 4 (RAL9003) (RAL9003)
94 Standard Escutcheon (1 in. NPT) (Figure 8) POLYESTER POLYESTER
Sidewall with TY3355 CHROME CHROME
53 9
Deep Escutcheon (1 in. NPT) (Figure 9) PLATED PLATED
Sidewall without TY3355
54 Escutcheon (1 in. NPT) (Figure 10)
TEMPERATURE ORDER
RATING(2) LENGTH(3)
Upright without TY3155
98 Escutcheon (1 in. NPT) (Figure 7) 0 135°F (57°C) 055 5.50 in.

Notes: 1 155°F (68°C) 082 8.25 in.


1. Escutcheon Finish applies to sprinklers provided with escutcheons.
2. 360°F (182°C) temperature rating applies to non-recessed sprinkler
assemblies. 2 175°F (79°C) 180 18.00 in.
3. Dry-type Sprinklers are furnished based upon “Order Length” as mea-
sured per Figures 3 through 10, as applicable, and for each individual 3 200°F (93°C) 187 18.75 in.
sprinkler where it is to be installed. After the measurement is taken,
round it to the nearest 1/4 inch increment.
4 286°F (141°C) 372 37.25 in.

5 360°F (182°C) 480 48.00 in.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–96
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry Sprinklers
DS-1 - Pendent, Upright & Horizontal Sidewall

Order Lengths: Order Lengths:


69,9 to 1219,2 mm Order Lengths: 12,7 to 1168,4 mm
(2-3/4" to 48") 95,3 to 1219,2 mm (1/2" to 46")
In 6,4 mm (1/4") (3-3/4" to 48") In 6,4 mm (1/4") 88,9 mm
In 6,4 mm (1/4") Increments (3-1/2")
Increments
Increments

108,0 ± 3,2 mm
(4-1/4" ± 1/8")

55,6 ± 3,2 mm 34,9 ± 3,2 mm 73,0 mm


(2-3/16" ± 1/8") 76,2 mm (1-3/8" ± 1/8") (2-7/8")
(3")
Figure 3 (TY3255) Figure 4 (TY3255) Figure 5 (TY3255)
Pendent Pendent With Standard Pendent
With Standard Escutcheon Recessed Escutcheon With Deep Escutcheon

Order Lengths:
69,9 to 1219,2 mm (2-3/4" to 48") 60,3 ± 3,2 mm
In 6,4 mm (1/4") Increments (2-3/8" ± 1/8")
Order Lengths:
127,0 to 1219,2 mm
(5" to 48")
In 6,4 mm (1/4")
76,2 mm Increments
(3")

Minimum
Figure 8 (TY3355) 44,5 mm(1-3/4")
Horizontal Sidewall With Standard Escutcheon Deflector
To Ceiling

Order Lengths:
12,7 to 1162,1 mm (1/2" to 45-3/4") 108,0 ± 3,2 mm Figure 6 (TY3255)
In 6,4 mm (1/4") Increments (4-1/4" ± 1/8") Pendent
Without Escutcheon

88,9 mm
(3-1/2")

Order Lengths:
127,0 to 1219,2 mm
Figure 9 (TY3355) (5" to 48")
Horizontal Sidewall With Deep Escutcheon IN 6,4 mm (1/4")
Increments

Order Lengths:
139,7 to 1219,2 mm (5-1/2" to 48") Minimum
In 6,4 mm (1/4") Increments 57,2 mm (2-1/4")
Deflector To
Mounting
Surface
Figure 7 (TY3155)
Figure 10 (TY3355) Upright
Horizontal Sidewall Without Escutcheon Without Escutcheon

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–97
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry Sprinklers
DS-1
Pendent, Upright & Horizontal Sidewall
K Factor K= 80 (5.6)
3
Thread Size ⁄4" NPT, 1" NPT (Std. Order) or ISO 7-R1
3
⁄4"= UL, C-UL
Approvals
1"= UL, C-UL, FM, NYC, Fire Academy of Russia

57°C (135°F), 68°C (155°F), 79°C (175°F),


Temperature
93°C (200°F), 141°C (286°F)

Escutcheon Finish Signal White, Chrome Plated, Brass Plated

Sprinkler Finish Natural Brass, Chrome Plated, Signal White

SIN TY3235, TY3135, TY3335, TY3935, TY3735

Wrench Type W-Type 7

Tech Data Sheet TFP510

Light hazard/Ordinary hazard • 3 mm bulb • Designed for use in applications where sprinklers and/or connecting piping may be
exposed to freezing conditions, or the sprinkler system is seasonally drained • Special assembly provides a seal at the main pipe to
prevent water from entering the assembly until the sprinkler operates • Designed for use in applications requiring dry sprinklers, or
where building construction or aesthetic considerations make the installation of dry horizontal sidewall sprinklers more desirable
than the dry pendent type

Order Lengths: Order Lengths: Order Lengths:


69,9 to 1219,2 mm 95,3 to 1219,2 mm 12,7 to 1168,4 mm
(2-3/4" to 48") (3-3/4" to 48") (1/2" to 46")
In 6,4 mm (1/4") 88,9 mm
In 6,4 mm (1/4") In 6,4 mm (1/4")
Increments (3-1/2")
Increments Increments

55,6 ± 3,2 mm
(2-3/16" ± 1/8")
108,0 ± 3,2 mm
(4-1/4" ± 1/8")
76,2 mm 34,9 ± 3,2 mm 73,0 mm
(3") (1-3/8" ± 1/8") (2-7/8")
Figure 3 Figure 4 Figure 5
Pendent 1" TY3235 And 3⁄4" TY3935 Pendent 1" TY3235 And 3⁄4" TY3935 Pendent 1" TY3235 And 3⁄4" TY3935
With Standard Escutcheon With Recessed Escutcheon With Deep Escutcheon

Order Lengths:
127,0 to 1219,2 mm Order Lengths:
(5" to 48") Figure 6 127,0 to 1219,2 mm Figure 7
In 6,4 mm (1/4") Pendent 1" TY3235 (5" to 48") Upright TY3135
Increments And 3⁄4" TY3935 IN 6,4 mm (1/4") Without Escutcheon
Without Escutcheon Increments 1" NPT Only

Minimum
44,5 mm (1-3/4")
Deflector
To Ceiling

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–98
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry Sprinklers

P/N* 60 – XXX – X – XXX

SIN
SPRINKLER ESCUTCHEON
Pendent with Standard TY3935 FINISH FINISH1
01
Escutcheon (3/4" NPT) (Figure 3)
SIGNAL WHITE
Pendent with Deep TY3935 0 CHROME PLATED
02 (RAL9003)
Escutcheon (3/4" NPT) (Figure 5)
SIGNAL WHITE
1 NATURAL BRASS
Pendent with Recessed TY3935 (RAL9003)
03
Escutcheon (3/4" NPT) (Figure 4)
2 NATURAL BRASS BRASS PLATED
Pendent without TY3935
04 SIGNAL WHITE SIGNAL WHITE
Escutcheon (3/4" NPT) (Figure 6) 4
(RAL9003) (RAL9003)

Sidewall with Standard TY3735 9 CHROME PLATED CHROME PLATED


05
Escutcheon (3/4" NPT) (Figure 8)

Sidewall with Deep TY3735


06
Escutcheon (3/4" NPT) (Figure 9)
TEMPERATURE SAMPLE
Sidewall without TY3735 RATINGS ORDER
07
Escutcheon (3/4" NPT) (Figure 10) LENGTHS2
0 135°F (57°C)
055 5.50”
Pendent with Standard TY3235
36 1 155°F (68°C)
Escutcheon (1" NPT) (Figure 3) 082 8.25”
2 175°F (79°C)
Pendent with Deep TY3235 180 18.00”
33
Escutcheon (1" NPT) (Figure 5)
3 200°F (93°C)
187 18.75”
Pendent with Recessed TY3235
37 4 286°F (141°C)
Escutcheon (1" NPT) (Figure 4) 372 37.25”

Pendent without TY3235 480 48.00”


32
Escutcheon (1" NPT) (Figure 6)

Sidewall with Standard TY3335


34
Escutcheon (1" NPT) (Figure 8)

Sidewall with Deep TY3335


43
Escutcheon (1" NPT) (Figure 9)
Notes:
Sidewall without TY3335 1. Escutcheon Finish applies to sprinklers provided with escutcheons.
44
Escutcheon (1" NPT) (Figure 10) 2. Dry-Type Sprinklers are furnished based upon “Order Length” as measured
per Figures 3 through 10, as applicable, and for each individual sprinkler
where it is to be installed. After the measurement is taken, round it to the
nearest 1/4 inch increment.
Upright without TY3135 *
38
Escutcheon (1” NPT) (Figure 7)

Order Lengths: Order Lengths:


12,7 to 1162,1 mm (1/2" to 45-3/4") 108,0 ± 3,2 mm 60,3 ± 3,2 mm
69,9 to 1219,2 mm (2-3/4" to 48")
In 6,4 mm (1/4") Increments (4-1/4" ± 1/8") (2-3/8" ± 1/8")
In 6,4 mm (1/4") Increments

76,2mm
88,9 mm (3")
(3-1/2")
Figure 8
Figure 9 1" TY3335 And 3⁄4" TY3735
1" TY3335 And 3⁄4" TY3735 Horizontal Sidewall
Horizontal Sidewall With Standard Escutcheon
With Deep Escutcheon Order Lengths:
139,7 to 1219,2 mm (5-1/2" to 48") Minimum Figure 10
In 6,4 mm (1/4") Increments 57,2mm (2-1/4") 1" TY3335 And
Deflector To 3
⁄4" TY3735
Mounting Horizontal Sidewall
Surface Without Escutcheon
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–99
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry Sprinklers
DS-1
Extended Coverage Horizontal Sidewall
K Factor K= 80 (5.6)

Thread Size 1" NPT (Standard Order), ISO 7-R1

Approvals UL, C-UL, NYC

Temperature 57°C (135°F), 68°C (155°F)

Escutcheon Finish Signal White, Chrome Plated, Brass Plated

Sprinkler Finish Natural Brass, Chrome Plated, Signal White

SIN TY3338, TY3358

Wrench Type W-Type 7

Tech Data Sheet TFP520

EC light hazard • 3mm and 5mm Glass Bulb • Lengths up to 1220 mm (48") • Designed for use in light hazard occupancy applications
requiring a dry sprinkler to cover areas up to: 4,9 m x 6,1 m (16’ x 20’) or 5,5 m x 4,9 m (18’ x 16’) • Special assembly provides a seal
at the main pipe to prevent water from entering the assembly until the sprinkler operates

P/N* 60 – XXX – X – XXX

ORDER
SPRINKLER ESCUTCHEON LENGTH**
SIN FINISH FINISH
055 5.50 in.
EC Sidewall 3 mm Bulb CHROME SIGNAL WHITE
350 TY3338 0
(1 in. NPT), 135°F (57°C) PLATED (RAL9003)
082 8.25 in.
EC Sidewall 3 mm Bulb NATURAL SIGNAL WHITE
351 TY3338 1
(1 in. NPT), 155°F (68°C) BRASS (RAL9003)
180 18.00 in.
NATURAL BRASS
2 BRASS PLATED
187 18.75 in.
EC Sidewall 5 mm Bulb SIGNAL WHITE SIGNAL WHITE
950 TY3358 4
(1 in. NPT), 135°F (57°C) (RAL9003) (RAL9003)
372 37.25 in.
EC Sidewall 5 mm Bulb CHROME CHROME
951 TY3358 9
(1 in. NPT), 155°F (68°C) PLATED PLATED
480 48.00 in.

Notes:
* Use Prefix “I” for ISO 7-R 1 Connection (e.g., I-60-351-1-180).
** Dry-Type Sprinklers are furnished based upon “Order Length” as measured per Figure 2.
After the measurement is taken, round it to the nearest 1/4 inch increment.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–100
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry Sprinklers
DS-1 - Extended Coverage Horizontal Sidewall

Order Lengths: 60,3 ± 3,2 mm


69,9 to 1219,2 mm (2-3/8" ± 1/8")
(2-3/4" to 48")
In 6,4 mm (1/4")
Increments

76,2 mm
(3")

Figure 2
Extended Coverage Horizontal Sidewall With Standard Escutcheon
TY3338 (3 mm Bulb) And TY3358 (5 mm Bulb)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–101
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry Sprinklers
DS-1 Stainless Steel
Pendent
K Factor K= 80 (5.6)

Thread Size 1" NPT (Standard Order), ISO 7-R1

TY3230 = UL, C-UL


Approvals
TY3250 = UL, C-UL, LPCB, CE

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F), 182°C (360°F)

Escutcheon Finish Stainless Steel

Sprinkler Finish Stainless Steel

SIN TY3230, TY3250

Wrench Type W-Type 7

Tech Data Sheet T


 FP560

3mm and 5mm Glass Bulb • Quick and Standard Response • The stainless-steel construction of these sprinklers extends the life of
a sprinkler beyond that of traditional copper alloy sprinklers exposed to corrosive atmospheres • Wet-pipe, dry-pipe, or preaction
installations • Designed for use in applications where sprinklers and/or connecting piping may be exposed to freezing conditions, or
the sprinkler system is seasonally drained • Special assembly provides a seal at the main pipe to prevent water from entering the
assembly until the sprinkler operates.

P/N* 60 – XXX – X– XXX


FINISH

SIN Stainless Steel for ORDER


6 Sprinkler and LENGTH
Escutcheon EXAMPLES(1)
SS Pendent Quick Response TY3230
11 with Standard Escutcheon (1 in. NPT) (Figure 10) 055 5.50 in.

SS Pendent Quick Response TY3230 TEMPERATURE


12 RATING(2)(3) 082 8.25 in.
with Recessed Escutcheon (1 in. NPT) (Figure 11)
0 135°F (57°C) 180 18.00 in.
SS Pendent Quick Response TY3230
13 with Deep Escutcheon (1 in. NPT) (Figure 12) 187 18.75 in.
1 155°F (68°C)
SS Pendent Quick Response TY3230 372 37.25 in.
14 2 175°F (79°C)
without Escutcheon (1 in. NPT) (Figure 13)
3 200°F (93°C) 480 48.00 in.

SS Pendent Standard Response TY3250


21 4 286°F (141°C)
with Standard Escutcheon (1 in. NPT) (Figure 10)

SS Pendent Standard Response TY3250 5 360°F (182°C)


22 with Recessed Escutcheon (1 in. NPT) (Figure 11)
Notes:
1. Dry-Type Sprinklers are furnished based upon “Order Length” as
SS Pendent Standard Response TY3250 measured per Figures 10 through 17 and for each individual sprin-
23 with Deep Escutcheon (1 in. NPT) (Figure 12) kler where it is to be installed. After taking the measurement, round
it to the nearest 1/4 inch increment.
2. Temperature rating 360°F (182°C) applies to non-recessed sprinkler
SS Pendent Standard Response TY3250
24 assemblies.
without Escutcheon (1 in. NPT) (Figure 13)
* Use Prefix “I” for ISO 7-R 1 Connection (e.g., I-60-110-6-055).

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–102
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry Sprinklers
DS-1 Stainless Steel - Pendent

Order Lengths:
Order Lengths: 69,9 to 1219,2 mm
95,3 to 1219,2 mm (2-3/4" to 48")
(3-3/4" to 48") In 6,4 mm (1/4")
In 6,4 mm (1/4") Increments
Increments

55,6 ±3,2 mm
(2-3/16" ±1/8")

34,9 ± 3,2 mm
73,0 mm 76,2 mm
(1-3/8" ± 1/8")
(2-7/8") (3")
Figure 10 Figure 11
Pendent With Standard Escutcheon Pendent With Recessed Escutcheon
TY3230 (3 mm Bulb) TY3230 (3 mm Bulb)
And TY3250 (5 mm Bulb) And TY3250 (5 mm Bulb)

Order Lengths:
12,7 to 1168,4 mm
(1/2" to 46") Order Lengths:
In 6,4 mm (1/4") 88,9 mm 127,0 to 1219,2 mm
Increments (3-1/2")
(5" to 48")
In 6,4 mm (1/4")
Increments

108,0 ±3,2 mm Minimum


(4-1/4" ±1/8") 44,5 mm (1-3/4")
Deflector
To Ceiling

Figure 12
Pendent With Deep Escutcheon Figure 13
TY3230 (3 mm Bulb) Pendent Without Escutcheon
And TY3250 (5 mm Bulb) TY3230 (3 mm Bulb) And
TY3250 (5 mm Bulb)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–103
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry Sprinklers
DS-1 Stainless Steel
Horizontal Sidewall, and Extended Coverage Horizontal Sidewall
K Factor K= 80 (5.6)

Thread Size 1" NPT (Standard Order), ISO 7-R1

Approvals UL, C-UL

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F), 182°C (360°F)

Escutcheon Finish Stainless Steel

Sprinkler Finish Stainless Steel

SIN TY3337, TY3357, TY3339

Wrench Type W-Type 7

Tech Data Sheet TFP560

3mm and 5mm Glass Bulb • Quick and Standard Response • The stainless-steel construction of these sprinklers extends the life of
a sprinkler beyond that of traditional copper alloy sprinklers exposed to corrosive atmospheres • Wet-pipe, dry-pipe, or preaction
installations • Extended coverages protecting areas up to 4,9 x 6,1m (16' x 20') • Designed for use in applications where sprinklers
and/or connecting piping may be exposed to freezing conditions, or the sprinkler system is seasonally drained • Special assembly
provides a seal at the main pipe to prevent water from entering the assembly until the sprinkler operates.

P/N* 60 – XXX – X– XXX

FINISH
SIN ORDER
Stainless Steel for LENGTH
6 Sprinkler and EXAMPLES(1)
SS HSW Quick Response Escutcheon
TY3337
15 Standard Coverage (Figure 14) 055 5.50 in.
with Standard Escutcheon (1 in. NPT)
SS HSW Quick Response 082 8.25 in.
TY3337 TEMPERATURE
16 Standard Coverage (Figure 15) RATING(2)(3)
with Deep Escutcheon (1 in. NPT) 180 18.00 in.
SS HSW Quick Response 0 135°F (57°C)
TY3337
17 Standard Coverage 187 18.75 in.
(Figure 16)
without Escutcheon (1 in. NPT)
1 155°F (68°C)
372 37.25 in.
SS HSW Standard Response TY3357 2 175°F (79°C)
25 Standard Coverage 480 48.00 in.
with Standard Escutcheon (1 in. NPT) (Figure 14)
3 200°F (93°C)
SS HSW Standard Response TY3357
26 Standard Coverage 4 286°F (141°C)
with Deep Escutcheon (1 in. NPT) (Figure 15)

SS HSW Standard Response 5 360°F (182°C)


27 Standard Coverage TY3357
without Escutcheon (1 in. NPT) (Figure 16) Notes:
1. Dry-Type Sprinklers are furnished based upon “Order Length” as
measured per Figures 10 through 17 and for each individual sprin
kler where it is to be installed. After taking the measurement, round
-
SS HSW Quick Response it to the nearest 1/4 inch increment.
TY3339(3)
18 Extended Coverage (Figure 17) 2. Temperature rating 360°F (182°C) applies to non-recessed sprinkler
with Standard Escutcheon (1 in. NPT) assemblies.
3. TY3339 HSW Quick Response Extended Coverage sprinkler is
available in 135°F (57°C) and 155°F (68°C) temperature ratings only.
* Use Prefix “I” for ISO 7-R 1 Connection (e.g., I-60-110-6-055).

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–104
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry Sprinklers
DS-1 Stainless Steel - Horizontal Sidewall, and Extended Coverage Horizontal Sidewall

Order Lengths:
69,9 to 1219,2 mm (2-3/4" to 48") 60,3 ± 3,2 mm
In 6,4mm (1/4") Increments (2-3/8" ± 1/8")

76,2 mm
(3")

Figure 14
Standard Coverage Horizontal Sidewall
With Standard Escutcheon
TY3337 (3 mm Bulb) And TY3357 (5 mm Bulb)

ORDER LENGTHS:
12,7 to 1162,1 mm (1/2" to 45-3/4") 108,0 ± 3,2 mm
IN 6,4 mm (1/4") INCREMENTS (4-1/4" ± 1/8")

88,9 mm
(3-1/2")

Figure 15
Standard Coverage Horizontal Sidewall
With Deep Escutcheon
TY3337 (3 mm Bulb) And TY3357 (5 mm Bulb)

Order Lengths:
139,7 To 1219,2 mm (5-1/2" To 48") Minimum
In 6,4 mm (1/4") Increments 57,2 mm (2-1/4")
Deflector To
Mounting
Surface

Figure 16
Standard Coverage Horizontal Sidewall Without Escutcheon
TY3337 (3 mm Bulb) And TY3357 (5 mm Bulb)

Order Lengths:
69,9 To 1219,2 mm 60,3 ± 3,2 mm
(2-3/4" To 48") (2-3/8" ± 1/8")
In 6,4 mm (1/4")
Increments

76,2 mm
(3")

Figure 17
Extended Coverage Horizontal Sidewall Sprinkler With Standard Escutcheon
TY3339 (3 mm Bulb)
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–105
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry Sprinklers
DS-8
Pendent, Standard and Quick Response
K Factor K=115 (8.0)

Thread Size 1" NPT (Standard Order) ISO 7-R1

Approvals UL, C-UL

57°C (135°F), 68°C (155°F), 79°C (175°F),


Temperature
93°C (200°F), 141°C (286°F), 182°C (360°F)

Signal White Polyester, Chrome Plated, Brass Plated,


Escutcheon Finish
Stainless Steel

Natural Brass, Chrome Plated,


Sprinkler Finish
Signal White Polyester

Standard Response: TY4255, (photo & drawing shown)


SIN
Quick Response: TY4235

Wrench Type W-Type 7

Standard Response: TFP503


Tech Data Sheet
Quick Response: TFP513

Standard coverage • All hazards (light hazards, horizontal sidewall) • 5 mm (SR) or 3mm (QR) bulb • Lengths up to 48" (1220 mm) •
Designed for use in applications where sprinklers and/or connecting piping may be exposed to freezing conditions, or the sprinkler
system is seasonally drained • Special assembly provides a seal at the main pipe to prevent water from entering the assembly
until the sprinkler operates • Designed for use in applications requiring dry sprinklers, or where building construction or aesthetic
considerations make the installation of dry horizontal sidewall sprinklers more desirable than the dry pendent type

P/N* 65 – XXX – X – XXX

STANDARD RESPONSE, FIGURE SPRINKLER ESCUTCHEON ORDER


STANDARD COVERAGE REFERENCE FINISH FINISH1 LENGTH3
Pendent with SIGNAL WHITE 055 5.50 in.
96 Figure 3 CHROME
Standard Escutcheon (1 in. NPT) 0 (RAL9003)
PLATED POLYESTER
Pendent with 082 8.25 in.
93 Figure 5 SIGNAL WHITE
Deep Escutcheon (1 in. NPT) NATURAL
1 (RAL9003) 180 18.00 in.
Pendent with BRASS
97 Figure 4 POLYESTER
Recessed Escutcheon (1 in. NPT) 187 18.75 in.
NATURAL BRASS
Pendent without 2
92 Figure 6 BRASS PLATED
Escutcheon (1 in. NPT) 372 37.25 in.
SIGNAL WHITE SIGNAL WHITE
4 (RAL9003) (RAL9003) 480 48.00 in.
POLYESTER POLYESTER

QUICK RESPONSE, FIGURE CHROME STAINLESS


8
STANDARD COVERAGE REFERENCE PLATED STEEL
CHROME CHROME
Pendent with 9
36 Figure 3 PLATED PLATED
Standard Escutcheon (1 in. NPT)
Pendent with Notes:
33 Figure 5 TEMPERATURE 1. Escutcheon Finish applies to sprinklers
Deep Escutcheon (1 in. NPT) RATING2 provided with escutcheons.
Pendent with 2. 360°F (182°C) temperature rating applies to
37 Figure 4 0 135°F (57°C)
Recessed Escutcheon (1 in. NPT) non-recessed sprinkler assemblies.
3. Dry-type Sprinklers are furnished based upon
Pendent without 1 155°F (68°C)
32 Figure 6 “Order Length” as measured per Figures 3 thru 6,
Escutcheon (1 in. NPT) as applicable, and for each individual sprinkler
2 175°F (79°C)
where it is to be installed. After the measurement
3 200°F (93°C) is taken, round it to the nearest 1/4 in. increment.

4 286°F (141°C)

5 360°F (182°C)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–106
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry Sprinklers
DS-8 - Pendent, Standard and Quick Response

Order Lengths:
Order Lengths: 95,3 to 1219,2 mm
69,9 to 1219,2 mm (3-3/4" to 48")
(2-3/4" to 48") in 6,4 mm (1/4")
in 6,4 mm (1/4") Increments
Increments

34,9 ± 3,2 mm 73,0 mm


55,6 ± 3,2 mm 76,2 mm (1-3/8" ± 1/8") (2-7/8" Dia.)
(2-3/16" ± 1/8") (3" Dia.)

Figure 3 Figure 4
Pendent With Standard Escutcheon Pendent With Recessed Escutcheon
TY4235 (3 mm Bulb) TY4235 (3 mm Bulb)
And TY4255 (5 mm Bulb) And TY4255 (5 mm Bulb)

Order Lengths:
19,1 to 1168 mm 88,9 mm
(3/4" to 46") (3-1/2" Dia.) Order Lengths:
in 6,4 mm (1/4") 133,4 to 1219 mm
Increments (5-1/4" to 48")
in 6,4 mm (1/4")
Increments

108,0 ± 3,2 mm Minimum


(4-1/4" ± 1/8") 44,5 mm (1-3/4")
Deflector
To Ceiling

Figure 5 Figure 6
Pendent With Deep Escutcheon Pendent Without Escutcheon
TY4235 (3 mm Bulb) TY4235 (3 mm Bulb) And
And TY4255 (5 mm Bulb) TY4255 (5 mm Bulb)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–107
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry Sprinklers
DS-2
Pendent
K Factor K= 161 (11.2)

Thread Size 1" NPT (Standard Order), ISO 7-R1

Approvals UL, C-UL, NYC

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F)

Escutcheon Finish Signal White, Chrome Plated, Brass Plated

Sprinkler Finish Natural Brass, Chrome Plated, Signal White

SIN TY5255, TY5235

Wrench Type W-Type 17

Tech Data Sheet TFP530

Standard coverage • All hazard (standard response) • Light hazard/Ordinary hazard (quick response) • 3 mm and 5 mm bulb • Extra
large orifice • Lengths to 1220 mm (48") • Designed for use in applications where sprinklers and/or connecting piping may be
exposed to freezing conditions, or the sprinkler system is seasonally drained • Special assembly provides a seal at the main pipe to
prevent water from entering the sprinkler assembly until the sprinkler operates

P/N* 61 – XXX – X – XXX

ORDER
LENGTH2

SPRINKLER ESCUTCHEON 055 5.50 in.


SIN FINISH FINISH1
Standard Response Pendent TY5255 CHROME SIGNAL WHITE 082 8.25 in.
10 0
with Flush Escutcheon (Figure 2) PLATED (RAL9003)
Standard Response Pendent TY5255 NATURAL SIGNAL WHITE 180 18.00 in.
11 1
with Recessed Escutcheon (Figure 3) BRASS (RAL9003)
Standard Response Pendent TY5255 SIGNAL WHITE SIGNAL WHITE 187 18.75 in.
12 4
with Extended Escutcheon (Figure 4) (RAL9003) (RAL9003)
Standard Response Pendent TY5255 NATURAL BRASS 372 37.25 in.
13 5
without Escutcheon (Figure 5) BRASS PLATED
CHROME CHROME 480 48.00 in.
9 PLATED PLATED
Quick Response Pendent TY5235
30 with Flush Escutcheon (Figure 2) TEMPERATURE
RATING
Quick Response Pendent TY5235
31 with Recessed Escutcheon (Figure 3)
0 135°F (57°C)
Quick Response Pendent TY5235
32 with Extended Escutcheon (Figure 4)
1 155°F (68°C)
Quick Response Pendent TY5235
35 without Escutcheon (Figure 5)
2 175°F (79°C)
Notes:
1. Escutcheon Finish applies to sprinklers with escutcheons.
2. Dry-Type Sprinklers are furnished based upon “Order Length” as measured per Figures 2 through 5, as 3 200°F (93°C)
applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken,
round it to the nearest 1/4 inch increment.
4 286°F (141°C)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–108
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry Sprinklers
DS-2 - Pendent

Order Lengths:
76,2 to 1219,2 mm Order Lengths:
(3" to 48") 88,9 to 1219,2 mm
In 6,4 mm (1/4") 92,1 mm (3-1/2" to 48")
In 6,4 mm (1/4") 92,1 mm
Increments (3-5/8") (3-5/8")
Increments

57,2 ±3,2 mm
(2-1/4 ±1/8") 41,3 ±3,2 mm
(1-5/8 ±1/8")

Figure 2 Figure 3
Series Ds-2 Dry-Type Pendent Series Ds-2 Dry-Type Pendent
With Flush Escutcheon With Recessed Escutcheon
Standard Response (TY5255) Standard Response (TY5255)
or Quick Response (TY5235) or Quick Response (TY5235)

Order Lengths:
25,4 to 1149,4 mm
(1" to 45-1/4")
In 6,4 mm (1/4")
Increments 92,1 mm
(3-5/8")
Order Lengths:
127,0 to 1219,2 mm
(5" to 48")
In 6,4 mm (1/4")
Increments
For Order Lengths
< 82,6 mm (3-1/4"):
123,8±3,2 mm (4-7/8±1/8")
-or- Minimum
For Order Lengths 57,2 mm
≥ 82,6 mm (3-1/4"): (2-1/4")
142,9±3,2 mm (5-5/8±1/8") Deflector
To Ceiling

Figure 4 Figure 5
Series Ds-2 Dry-Type Pendent Series Ds-2 Dry-Type Pendent
With Extended Escutcheon Without Escutcheon
Standard Response (TY5255) Standard Response (TY5255)
or Quick Response (TY5235) or Quick Response (TY5235)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–109
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry Sprinklers
DS-2
Extended Coverage Pendent
K Factor K= 161 (11.2)

Thread Size 1" NPT (Standard Order), ISO 7-R1

Approvals UL, C-UL, NYC

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F)

Escutcheon Finish Signal White, Chrome Plated, Brass Plated

Sprinkler Finish Natural Brass, Chrome Plated, Signal White

SIN TY5238

Wrench Type W-Type 17

Tech Data Sheet TFP540

EC light hazard & ordinary hazard • 3 mm bulb • Extra large orifice • Lengths to 1220 mm (48") • Designed for use in applications
where sprinklers and/or connecting piping may be exposed to freezing conditions, or the sprinkler system is seasonally drained •
Special assembly provides a seal at the main pipe to prevent water from entering the assembly until the sprinkler operates

P/N* 61 – XXX – X – XXX


SPRINKLER ESCUTCHEON
FINISH FINISH(1)
SIGNAL WHITE
CHROME
SIN 0 (RAL9003)
PLATED POLYESTER
Pendent with TY5238 SIGNAL WHITE
40 NATURAL
Flush Escutcheon (Figure 2) 1 (RAL9003)
BRASS POLYESTER
Pendent with TY5238
41 Recessed Escutcheon (Figure 3) SIGNAL WHITE SIGNAL WHITE
Pendent with TY5238 4 (RAL9003) (RAL9003)
42 POLYESTER POLYESTER
Extended Escutcheon (Figure 4)
Pendent without TY5238 NATURAL BRASS
43 5
Escutcheon (Figure 5) BRASS PLATED

Notes: CHROME CHROME


1. Escutcheon Finish applies to sprinklers with escutcheons. 9
2. 286°F (141°C) temperature rating applies to non-recessed sprin-
PLATED PLATED
kler assemblies.
3. Dry-Type Sprinklers are furnished based upon “Order Length” as
measured per Figures 2 through 5, as applicable, and for each
individual sprinkler where it is to be installed. After the measure-
ment is taken, round it to the nearest 1/4 inch increment. TEMPERATURE ORDER
* RATING(2) LENGTH(3)

0 135°F (57°C) 055 5.50 in.

1 155°F (68°C) 082 8.25 in.

2 175°F (79°C) 180 18.00 in.

3 200°F (93°C) 187 18.75 in.

4 286°F (141°C) 372 37.25 in.

480 48.00 in.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–110
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry Sprinklers
DS-2 - Extended Coverage Pendent

Order Lengths: Order Lengths:


76,2 to 1219,2 mm 88,9 to 1219,2 mm
(3" to 48") (3-1/2" to 48")
In 6,4 mm (1/4") 92,1 mm In 6,4 mm (1/4") 92,1 mm
Increments (3-5/8") (3-5/8")
Increments

57,2 ±3,2 mm
(2-1/4 ±1/8") 41,3 ±3,2 mm
(1-5/8 ±1/8")

Figure 2 Figure 3
Series DS-2 Dry-Type Pendent Sprinkler Series DS-2 Dry-Type Pendent Sprinkler
(ECLH/ECOH) (ECLH/ECOH)
With Flush Escutcheon (TY5238) With Recessed Escutcheon (TY5238)

Order Lengths:
25,4 to 1149,4 mm
(1" to 45-1/4")
In 6,4 mm (1/4")
Increments 92,1 mm Order Lengths:
(3-5/8") 127,0 to 1219,2 mm
(5" to 48")
In 6,4 mm (1/4")
Increments

For Order Lengths


< 82,6 mm (3-1/4"):
123,8 ±3,2 mm (4-7/8±1/8")
Minimum
-or-
57,2 mm
For Order Lengths
(2-1/4")
≥ 82,6 mm (3-1/4"):
Deflector
142,9 ±3,2 mm (5-5/8±1/8")
To Ceiling

Figure 4 Figure 5
Series DS-2 Dry-Type Pendent Sprinkler Series DS-2 Dry-Type Pendent Sprinkler
(ECLH/ECOH) (ECLH/ECOH)
With Extended Escutcheon (TY5238) Without Escutcheon (TY5238)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–111
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry Sprinklers
DS-C
Concealed Pendent
K Factor K=80 (5.6)

Thread Size 1" NPT (Standard Order), ISO 7-R1

Approvals UL, C-UL, NYC

68°C (155°F) - Sprinkler, 59°C (139°F) - Cover Plate,


Temperature
93°C (200°F) - Sprinkler, 74°C (165°F) - Cover Plate

Grey White, Brass, Pure White, Signal White, Jet Black,


Cover Plate Finish
Chrome, Custom

SIN TY3535, TY3555

Wrench Type RFII

Tech Data Sheet TFP515

Standard coverage • All hazard (standard response) • Light hazard/ordinary hazard (quick response) • 3 mm and 5 mm bulb •
Lengths to 1220 mm (48") • Designed for use in applications where sprinklers and/or connecting piping may be exposed to freezing
conditions, or the sprinkler system is seasonally drained • Special assembly provides a seal at the main pipe to prevent water from
entering the sprinkler assembly until the sprinkler operates.

P/N* 60 – XXX – 1 – XXX

TEMPERATURE ORDER
SIN LENGTH**
RATING
Quick Response 055 5.50 in.
46 TY3535 1 155°F (68°C)
(3 mm Bulb)
Standard Response 082 8.25 in.
86 TY3555 3 200°F (93°C)
(5 mm Bulb)

Note 180 18.00 in.


*
(for example, I-60-461-1-180).
** Dry-Type Sprinklers are furnished based upon “Order Length” as 187 18.75 in.
measured per Figure 2, for each individual sprinkler where it is to
be installed. After the measurement is taken, round it to the near-
est 1/4 inch increment. 372 37.25 in.

480 48.00 in.

Cover Plate
Part No. Temp. For use with
Cover Plate
Cover Sprinkler Finish
°C °F
Plate Temp.
567920135 59 139 68°C, 155°F Grey White (RAL9002)
567920165 74 165 93°C, 200°F Grey White (RAL9002)
567921135 59 139 68°C, 155°F Brass
567921165 74 165 93°C, 200°F Brass
567923135 59 139 68°C, 155°F Pure White (RAL9010)
567923165 74 165 93°C, 200°F Pure White (RAL9010)
567924135 59 139 68°C, 155°F Signal White (RAL9003)
567924165 74 165 93°C, 200°F Signal White (RAL9003)
567926135 59 139 68°C, 155°F Jet Black (RAL9005)
597926165 74 165 93°C, 200°F Jet Black (RAL9005)
567929135 59 139 68°C, 155°F Chrome
567929165 74 165 93°C, 200°F Chrome
56792X135 59 139 68°C, 155°F Custom
56792X165 74 165 93°C, 200°F Custom

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–112
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry Sprinklers
DS-C - Concealed Pendent

Order Lengths:
127,0 mm (5")
to 1219,2 mm (48")
In 6,4 mm (1/4")
Figure 2 Increments
Series DS-C Standard Coverage Dry-Type
Concealed Pendent Sprinkler
TY3535 (3mm Bulb)

3-1/4" DIA.
(82,6 mm)

Order Lengths:
127,0 mm (5")
Figure 2
to 1219,2 mm (48")
Series DS-C Standard Coverage Dry-Type
In 6,4 mm (1/4")
Concealed Pendent Sprinkler
Increments
TY3555 (5mm Bulb)

3-1/4" DIA.
(82,6 mm)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–113
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry Sprinklers
DS-ECC
Extended Coverage Concealed Pendent
K Factor K= 80 (5.6)

Thread Size 1" NPT (Standard Order), ISO 7-R1

Approvals UL, C-UL, NYC

68°C (155°F) - Sprinkler, 59°C (139°F) - Cover Plate,


Temperature
93°C (200°F) - Sprinkler, 74°C (165°F) - Cover Plate

Grey White, Brass, Pure White, Signal White, Jet Black,


Cover Plate Finish
Chrome, Custom

SIN TY3539

Wrench Type RFII

Tech Data Sheet TFP518

EC light hazard/EC ordinary hazard • 3 mm bulb • Lengths to 1220 mm (48") • Designed for use in applications where sprinklers
and/or connecting piping may be exposed to freezing conditions, or the sprinkler system is seasonally drained • Special assembly
provides a seal at the main pipe to prevent water from entering the sprinkler assembly until the sprinkler operates

P/N* 60 – 45X – 1 – XXX


ORDER
LENGTH**
TEMPERATURE
SIN RATING
055 5.50 in.
45 DS-ECC (3 mm Bulb) TY3539 1 155°F (68°C)
082 8.25 in.
3 200°F (93°C)
180 18.00 in.
Notes
*
180 187 18.75 in.
** Dry-Type Sprinklers are furnished based upon “Order Length” as
measured per Figure 2, as applicable, and for each individual
sprinkler where it is to be installed. After the measurement is 372 37.25 in.
taken, round it to the nearest 1/4 inch increment

480 48.00 in.

Cover Plate
Part No. Temp. For use with
Cover Plate
Cover Sprinkler Finish
°C °F
Plate Temp.
567920135 59 139 68°C, 155°F Grey White (RAL9002)
567920165 74 165 93°C, 200°F Grey White (RAL9002)
567921135 59 139 68°C, 155°F Brass
567921165 74 165 93°C, 200°F Brass
567923135 59 139 68°C, 155°F Pure White (RAL9010)
567923165 74 165 93°C, 200°F Pure White (RAL9010)
567924135 59 139 68°C, 155°F Signal White (RAL9003)
567924165 74 165 93°C, 200°F Signal White (RAL9003)
567926135 59 139 68°C, 155°F Jet Black (RAL9005)
597926165 74 165 93°C, 200°F Jet Black (RAL9005)
567929135 59 139 68°C, 155°F Chrome
567929165 74 165 93°C, 200°F Chrome
56792X135 59 139 68°C, 155°F Custom
56792X165 74 165 93°C, 200°F Custom

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–114
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry Sprinklers
DS-ECC - Extended Coverage Concealed Pendent

Order Lengths:
127,0 mm (5")
to 1219,2 mm (48")
IN 6,4 mm (1/4")
Increments

82,6 mm
(3-1/4")

Figure 2
Series DS-ECC Extended Coverage Dry-Type
Pendent Concealed Sprinkler

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–115
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry Sprinklers
DS-3
Extended Coverage Horizontal Sidewall
K Factor K= 161 (11.2)

Thread Size 1" NPT (Standard Order), ISO 7-R1

Approvals UL, C-UL

Temperature 68°C (155°F), 93°C (200°F)

Escutcheon Finish Signal White, Chrome Plated, Brass Plated

Sprinkler Finish Natural Brass, Chrome Plated, Signal White

SIN TY5339

Wrench Type W-Type 8

Tech Data Sheet TFP550

EC ordinary hazard • 3 mm bulb • Lengths to 1220 mm (48") • Designed for use in applications where sprinklers and/or connecting
piping may be exposed to freezing conditions, or the sprinkler system is seasonally drained • Ideal for Exterior Loading Docks and
Covered Areas and can eliminate the need for dry or anti-freeze systems.

P/N* 61 — XXX — X — XXX

SPRINKLER ESCUTCHEON ORDER


ESCUTCHEON TYPE FINISH FINISH1 LENGTH2
Flush Escutcheon NATURAL BRASS 055 5.50 in.
161 1
(1 in. NPT), 155°F (68°C) BRASS PLATED
Flush Escutcheon 082 8.25 in.
163 SIGNAL WHITE SIGNAL WHITE
(1 in. NPT), 200°F (93°C)
4 (RAL9003) (RAL9003)
Deep Escutcheon POLYESTER POLYESTER 180 18.00 in.
171 (1 in. NPT), 155°F (68°C)
Deep Escutcheon CHROME CHROME 187 18.75 in.
173 9
(1 in. NPT), 200°F (93°C) PLATED PLATED
Without Escutcheon SIGNAL WHITE 372 37.25 in.
151 CHROME
(1 in. NPT), 155°F (68°C) 0 (RAL9003)
PLATED
Without Escutcheon POLYESTER
153 480 48.00 in.
(1 in. NPT), 200°F (93°C)
Notes:
1. Does not apply to assemblies without escutcheon.
2. Dry-Type Sprinklers are furnished based upon “Order Length” as measured per Figures 2, 3 & 4.
3. After the measurement is taken, round it to the nearest 1/4 inch increment.
*

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–116
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry Sprinklers
DS-3 - Extended Coverage Horizontal Sidewall

Order Lengths:
76,2 to 1149,4 mm (3" to 45-1/4") 50,8 ±3,2 mm
In 1/4" (6,4 mm) Increments (2" ±1/8")

3-11/16" DIA.
(93,7 mm)

Figure 2
Series DS-3 ECOH Horizontal Sidewall Dry-Type Sprinkler
With Flush Escutcheon (TY5339)

Order Lengths:
25,4 to 1117,6 mm (1" to 44") 104,8 ± 9,5 mm
In 6,4 mm (1/4") Increments (4-1/8" ± 3/8")

88,9 mm
(3-1/2")

Figure 3
Series DS-3 ECOH Horizontal Sidewall Dry-Type Sprinkler
With Deep Escutcheon (TY5339)

Order Lengths: Minimum


133,4 to 1219,2 mm (5-1/4" to 48") 57,2 mm
In 6,4 mm (1/4") Increments (2-1/4")
Deflector To
Mounting
Surface

Figure 4
Series DS-3 ECOH Horizontal Sidewall Dry-Type Sprinkler
Without Escutcheon (TY5339)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–117
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry Sprinklers
DSB-2

Dry Sprinkler Boot (For Use With TFP Dry Type Sprinklers)

1 Boot, 2 Strap Ties, and


Includes 0.9L (1/3 oz.) of Adhesive
(quantity of adhesive is sufficient for installing 1 Boot)

Tech Data Sheet TFP591

Helps to close the air gap created by the clearance hole through a wall or ceiling through which the dry type sprinkler has
penetrated • Helps to stop the air exchange between the inside and outside of the freezer (or any other type of similar
construction) to help prevent transfer of moist air into the freezer space

G5
DS-1 Dry Sprinkler Guards

Approvals UL

Finish Zinc Chromate

Tech Data Sheet TFP780

The TYCO Model G5 Sprinkler Guards are designed to be used in areas that make the sprinklers susceptible to mechanical or
physical damage • For use with Series DS-1 Dry Sprinklers standard, deep, and no escutcheons

95,3 mm
(3-3/4")

50,8 mm
(2") 69,9 x 76,2 mm
(2-3/4" x 3")

93,7 mm
(3-11/16")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–118
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
Intended for specific applications such as combustible concealed spaces and areas subject to corrosion.
- Attic Spaces - Corrosive Environments

- High Security Institutions - Window Protection

www.tyco-fire.com 1–119
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


Attic

BB (Back-to-Back), SD (Single Directional), HIP, & AP (Attic Plus)


K Factor K= 60 (4.2), K= 80 (5.6), K= 115 (8.0)
1
Thread Size ⁄2" NPT • 3 ⁄4" NPT

Approvals UL, C-UL

93°C (200°F) for BB (K=60 and K=115), HIP, AP


Temperature
100°C (212°F) for BB (K=80), SD

BB Series Sprinkler Finish Natural Brass


Back-To-Back TY4180, TY4181, TY4182 TY3180, TY3181, TY3182
SIN TY2180, TY2181, TY2182 TY3183, TY3184, TY3185
TY3187, TY3190, TY2190

Wrench Type W-TYPE 3, W-TYPE 6, W-TYPE 20

Tech Data Sheet TFP610

“Specific Application Sprinklers for Protecting Attics” • 3 mm bulb or solder type


• Wet or dry pipe systems • Provides a tested method of protecting an attic •
Provides a specific cost advantage by reducing the amount of piping required •
Cover attics to 18.3m (60’) wide with a single line of piping, eliminating the need
SD Series for as many as five branch lines • Saves up to 80% of the piping that would be
Single Directional required with standard sprinklers while providing a higher level of protection.

Spray Patterns
Back-To-Back HIP Application Single Directional
Application Application

HIP

BB SD

AP Series
Attic Plus

AREA 2
WITH AP
AREA 1
WITH BB
AREA 3
WITH AP HIP AP
SPRINKLERS SPRINKLERS SPRINKLERS

STAGGERED
SPACING WHEN
MORE THAN
ONE ROW

MINIMUM
SEPARATION
15'-0" (4,6 m)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–120
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
Attic
57,2 mm
(2-1/4")

BB1, BB2, & BB3 • K=115 (8.0), 80 (5.6), 60 (4.2) • TFP610


Approvals &
FLOW FLOW Temp.
Finish Listings
Part No. Model SIN Pitch
Code
°C °F

UL
63,5 mm
BB Series
(2-1/2") K=60 (4.2)
BB1, BB2, & BB3 - 115 (8.0) - 3 ⁄4" NPT
& 80 (5.6)
516231200 BB1 TY4180 93 [200] 4:12 1 √
516211200 BB2 TY4181 93 [200] 7:12 1 √
516221200 BB3 TY4182 93 [200] 10:12 1 √
41,3 mm
BB1, BB2, & BB3 - 80 (5.6) - 1 ⁄ 2" NPT
(1-5/8") 516231200 BB1 TY3180 100 [212] 4:12 1 √
516211200 BB2 TY3181 100 [212] 7:12 1 √
516221200 BB3 TY3182 100 [212] 10:12 1 √
BB1, BB2, & BB3 - 60 (4.2) - 1 ⁄ 2" NPT
516231200 BB1 TY2180 93 [200] 3:12 1 √
54,0 mm BB Series 516211200 BB2 TY2181 93 [200] 7:12 1 √
(2-1/8") K=115 (8.0) 516221200 BB3 TY2182 93 [200] 10:12 1 √

54,0 mm
(2-1/8")
SD1, SD2, & SD3 • K=80 (5.6) • TFP610
Approvals &
Temp.
Finish Listings
FLOW Part No. Model SIN Pitch
Code
°C °F

UL
SD Series
K=80 (5.6) SD1, SD2, & SD3 - 80 (5.6) - 1 ⁄ 2" NPT
76,2 mm 506111212 SD1 TY3183 100 [212] 4:12 1 √
(3") 506121212 SD2 TY3184 100 [212] 7:12 1 √
506131212 SD3 TY3185 100 [212] 10:12 1 √

50,8 mm
(2") HIP • K=80 (5.6) • TFP610
Approvals &
Temp.
Finish Listings
HIP Series Part No. Model SIN Pitch
FLOW K=80 (5.6) Code
°C °F
UL

54,0 mm
(2-1/8") HIP - 80 (5.6) - 1 ⁄ 2" NPT
516201200 HIP TY3187 93 [200] 4:12 1 √

42,9 mm
(1-11/16")
AP • K=80 (5.6) & 60 (4.2) • TFP610
Approvals &
Temp.
Finish Listings
Part No. Model SIN Pitch
AP Series Code
°C °F
UL

K=80 (5.6)
57,2 mm & 60 (4.2)
(2-1/4") AP - K=80 (5.6) - 1 ⁄ 2" NPT
506251200 AP TY3190 93 [200] 3:12 1 √
AP - K=60 (4.2) - 1 ⁄ 2" NPT
506241200 AP TY2190 93 [200] 3:12 1 √

Finish Code: 1=Plain Brass


Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–121
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


RAVEN Studio Sprinkler
Pendent & Horizontal Sidewall Sprinklers
K Factor K= 80 (5.6)

Thread Connection
Adapter: 1 ⁄ 2" NPT x ISO 228 G3 ⁄ 8"
Thread Size
Sprinkler: ISO 228 G3 ⁄ 8"
Note: Threads per ISO 228 are parallel pipe threads.

Approvals UL, C-UL

Temperature 74°C (165°F)

Sprinkler Finish White, Grey, Custom

White, Grey, Chrome/Electropolish, Custom,


Escutcheon Finish
Primed White or Grey (for paint-in-place)

Standard Coverage: TY1281 - Pendent, TY1381 - HSW


SIN
Extended Coverage: TY1282 - Pendent, TY1382 - HSW

Wrench Type W-Type 25

Tech Data Sheet TFP658

TYCO RAVEN Studio Sprinklers 5.6K Pendent and Horizontal Sidewall (HSW) Quick Response, Standard Coverage for Light and
Ordinary Hazard applications and Extended Coverage for Light Hazard applications only, are intended for use in areas as designed
per NFPA 13 • The flush design is made aesthetically appealing by concealing the deflector and other operating parts behind the
link assembly. • Additionally, RAVEN Studio is the only sprinkler UL Listed with a paint-in-place escutcheon. Both the sprinkler and
escutcheon are also available in a range of factory-painted custom colours.

RAVEN Studio • K=80 (5.6) • TFP658 Carbon Steel Escutcheons


Approvals & Carbon Steel
Temp. For use
Finish Listings Part No.
Part No. SIN
Code
with Cover Plate
°C °F Style J Style K
UL

Sprinkler Finish
76mm 101mm
Temp.
Standard Coverage - Pendent (3") Dia. (4") Dia.
503104165 TY1281 74 [165] 4 √ 563064010 563084010 White
503109165 TY1281 74 [165] 9 √ 563067010 563087010 Grey
50310X165 TY1281 74 [165] X √ 563069010 563089010 74°C, Chrome
Standard Coverage - Horizontal Sidewall 563060004 563080004 165°F Primed White
503124165 TY1381 74 [165] 4 √ 563060007 563080007 Primed Grey
503129165 TY1381 74 [165] 9 √ 56306X010 56308X010 Custom Colour
50312X165 TY1381 74 [165] X √
Extended Coverage - Pendent Stainless Steel Escutcheons
503114165 TY1282 74 [165] 4 √
Stainless Steel
503119165 TY1282 74 [165] 9 √ For use
Part No.
50311X165 TY1282 74 [165] X √ with Cover Plate
Extended Coverage - Horizontal Sidewall Style J Style K Finish
Sprinkler
503184165 TY1382 74 [165] 4 √ 76mm 101mm
Temp.
503189165 TY1382 74 [165] 9 √ (3") Dia. (4") Dia.
50318X165 TY1382 74 [165] X √ 563074010 563094010 White
563077010 563097010 Grey
563079010 563099010 74°C, Electropolish*
Thread Adapters 563070004 563090004 165°F Primed White
Part No. Size 563070007 563090007 Primed Grey
913100075 Short 19 mm (3 ⁄4") 56307X010 56309X010 Custom Colour
913100100 Standard 25 mm (1") * Chrome-coated appearance
913100150 Medium 38 mm (1-1 ⁄ 2")
913100200 Long 50 mm (2")

Finish Code: 4=White, 9=Grey, X=Custom

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–122
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
RAVEN Studio Sprinkler

48 mm
11mm
(1-7/8")
(7/16")

Style J: 76mm (3")


Style K: 101mm (4")

35 mm
(1-3/8")
11mm
(7/16")

Style J: 76mm (3")


35 mm Style K: 101mm (4")
(1-3/8")

35 mm
(2-13/16")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–123
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


RAVEN
Institutional Pendent & Horizontal Sidewall
K Factor K= 80 (5.6)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL

Temperature 74°C (165°F)

Escutcheon Material Carbon Steel, or Stainless Steel

Escutcheon Finish Grey, Chrome, White, or Electropolished (SS only)

Sprinkler Finish Grey or White

SIN TY3281, TY3282, TY3381, TY3382

Wrench Type W-Type 25

Tech Data Sheet TFP651

Quick Response • Standard and Extended Coverage • Designed for use in areas such as correctional, detention, and mental health
care facilities as well as other commercial buildings • Both the pendent and horizontal sidewall styles are available for standard or
extended coverage applications • Tamper-resistant features • 12,1 bar (175 psi).

RAVEN Studio • K=80 (5.6) • TFP651 Carbon Steel Escutcheons


Approvals & Carbon Steel
Temp. For use
Finish Listings Part No.
Part No. SIN
Code
with Cover Plate
°C °F Style F Style G
UL

Sprinkler Finish
76mm 101mm
Temp.
Standard Coverage - Pendent (3") Dia. (4") Dia.
503144165 TY3281 74 [165] 4 √ 563144010 563124010 White
74°C,
503149165 TY3281 74 [165] 9 √ 563147010 563127010 Grey
165°F
Standard Coverage - Horizontal Sidewall 563149010 563129010 Chrome Coated
503164165 TY3381 74 [165] 4 √
503169165 TY3381 74 [165] 9 √ Stainless Steel Escutcheons
Extended Coverage - Pendent Stainless Steel
Part No.
For use
503154165 TY3282 74 [165] 4 √
503159165 TY3282 74 [165] 9 √
with Cover Plate
Style F Style G Finish
Extended Coverage - Horizontal Sidewall Sprinkler
76mm 101mm
503174165 TY3382 74 [165] 4 √ Temp.
(3") Dia. (4") Dia.
503179165 TY3382 74 [165] 9 √ 563184010 563194010 White
74°C,
563187010 563197010 Grey
165°F
563189010 563199010 Electropolish*
* Chrome-coated appearance

Finish Code: 4=White, 9=Grey

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–124
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
RAVEN

54 mm
(2-1/8")

35 mm
46 mm (1-3/8")
(1-13/16")

19 mm
35 mm (3/4")
(1-3/8")

16 mm
(5/8")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–125
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


FSC
Flush Pendent Quick Response
K Factor K= 80 (5.6)

Thread Size G3 ⁄ 8" DIN ISO 228

Approvals CE, VdS

Temperature 74°C (165°F)

Escutcheon Finish Grey, White

Sprinkler Finish Grey or White

SIN TY3200

Wrench Type W-Type 25

Tech Data Sheet TFP645

Quick Response • The TYCO Model FSC 80 K-factor Flush Sprinkler is a quick response standard coverage sprinkler designed for
use in areas such as offices, hospitals, churches, schools, apartments, and hotels. • For applications in poured concrete ceiling/
floor assemblies, a unique Installation Cup is used to form the recessed cavity into which the FSC Sprinkler is installed. • The FSC
Sprinkler, with a heat sensitive solder type release element, is rated as a quick response sprinkler.

FSC • K=80 (5.6) • TFP645 Style H Escutcheons - 85mm Dia.


Approvals & Part No.
Temp. For use with
Finish Listings Finish
Part No. Style H Sprinkler Temp.
Code
VdS

°C °F 85mm
CE

563134010 74°C, White


Concrete Ceiling Application 563139010 165°F Grey
503134165 74 [165] 4 √ √
503139165 74 [165] 9 √ √ Thread Extension and Adapters
Suspended Ceiling Application Part No. Desc.
513134165 74 [165] 4 √ √
913131008 Thread Extension
513139165 74 [165] 9 √ √
913131007 Adapter
This sprinkler comes with 2 adaptors mentioned here. These
adaptors are needed to fit in the MLC-S piping systems.

51 mm
(2")

16 mm
3 mm (5/8")
35 mm DIA. (1/8")
(1-3/8")
85 mm DIA.
(3-3/8")

Finish Code: 4=White, 9=Grey

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–126
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
TFP PH2
Institutional Pendent Sprinklers
K Factor K= 80 (5.6)
1
Thread Size ⁄ 2" NPT

Approvals UL, C-UL, NYC

Temperature 74°C (165°F), 100°C (212°F)

Escutcheon Finish Chrome Plated

Sprinkler Finish Chrome Plated

SIN TY3290

Wrench Type 1509-3

Tech Data Sheet TFP650

The TYCO Model TFP PH2, 5.6 K-factor, Institutional Pendent Sprinklers are standard response standard coverage, fusible solder
type spray sprinklers designed for use in areas such as correctional, detention, and mental health care facilities. • The unique
features of the Model TFP PH2 provide a tamper resistant sprinkler design that helps eliminate the opportunity for individuals to
injure themselves or others with the components of a fire sprinkler. • The Model TFP PH2 optimises an aesthetically appealing flush
design that conceals most of the operating parts.

TFP PH2 • K=80 (5.6) • TFP650


Style A
Approvals & 41.1 mm
Temp. (1.62")
Finish Listings
Part No.
Code
°C °F
UL

Sprinkler Assemblies
511049165 74 [165] 9 √
511049212 100 [212] 9 √
4.8 mm
Escutcheons (3/16")
82.6 mm 30.2 mm
Escutcheon (3-1/4") (1.19")
Part No. Finish
Style
560127622 Style A Chrome Plated Style B1
560017511 Style B1 Chrome Plated
560017513 Style C Chrome Plated
30.2 mm
(1-3/16")

37.6 to 43.2 mm
(1.48" to 1.70")

127.0 mm
(5")

Style C

71.4 mm
(2.81") 80.8 mm
(3.18")

2-9/16" 65.8 to 71.4 mm


(65.1 mm) (2.59" to 2.81")

4-1/4" DIA.
Finish Code: 9=Chrome Plated
(108.0 mm)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–127
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


TFP PH5
Institutional Horizontal Sidewall Sprinklers
K Factor K= 80 (5.6)
1
Thread Size ⁄ 2" NPT

Approvals UL, C-UL, NYC

Temperature 74°C (165°F)

Escutcheon Finish Chrome Plated

Sprinkler Finish Chrome Plated

SIN TY3390

Wrench Type 1509-3

Tech Data Sheet TFP654

The TYCO Model TFP PH2, 5.6 K-factor, Institutional Pendent Sprinklers are standard response standard coverage, fusible solder
type spray sprinklers designed for use in areas such as correctional, detention, and mental health care facilities. • The unique
features of the Model TFP PH2 provide a tamper resistant sprinkler design that helps eliminate the opportunity for individuals to
injure themselves or others with the components of a fire sprinkler. • The Model TFP PH2 optimises an aesthetically appealing flush
design that conceals most of the operating parts.

TFP PH2 • K=80 (5.6) • TFP654 Escutcheons


Approvals & Escutcheon
Temp. Part No. Finish
Finish Listings Style
Part No. 560017512 Style B2 Chrome Plated
Code
°C °F
UL

560017513 Style C Chrome Plated


Sprinkler Assemblies
511069165 74 [165] 9 √ Style B2

108.0 mm
(4-1/4")

71.4 mm
(2.81")
71.4 mm
(2.81")
Style C

127.0 mm
(5")
80.8 mm
(3.18")

37.6 mm
Finish Code: 9=Chrome Plated (1.48")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–128
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
CWS
Specific Application Concealed Pendent Vertical Sidewall Window Sprinkler
K Factor K=80 (5.6)

Thread Size 1⁄2" NPT

Approvals UL, C-UL, ICC

71°C/160°F - Sprinkler, 59°C/139°F - Cover Plate,


Temperature
100°C/212°F - Sprinkler, 74°C/165°F - Cover Plate

Ivory, Bright Chrome, Beige, Pure White,


Cover Plate Finish Signal White, Grey White, Brown, Black,
Brushed Brass, Brushed Chrome, Custom

SIN TY3498

Wrench Type W-Type 39

Tech Data Sheet TFP621

Designed to provide a two-hour fire-resistance-rating to protect non-rated glazing • UL and C-UL Listed as a specific application
automatic window sprinkler • Compliant with the International Building Code, fire-resistant rating evaluated in ICC ESR-2397 • Flat-
plate design conceals the sprinkler above the ceiling

CSW-VSW, K=80 (5.6), 1 ⁄ 2" NPT

63,5 mm K=80 [5.6] • 1 ⁄ 2” NPT • TFP621


(2-1/2" DIA.) 12,7 mm (1/2") Part No. Temp. Approvals & Listings
Threaded
Adjustment Finish
CWS-VSW

C-UL
UL
°C °F Code
SIN TY3498

506300165 71 [160] 1 √ √
49.2 mm ± 6.4mm 506300212 100 [212] 1 √ √
(1-15/16"±1/4")

Cover Plate
Part No. Temp. For use with
Cover Plate
Cover Sprinkler Finish
°C °F
Plate Temp.
81,0 mm 4,8 mm 562140135 59 139 71°C, 160°F
(3-3/16" DIA.) (3/16") Ivory (RAL1015)
562140165 74 165 100°C, 212°F
562141135 59 139 71°C, 160°F
Bright Chrome
562141165 74 165 100°C, 212°F
562142135 59 139 71°C, 160°F
Beige (RAL1001)
562142165 74 165 100°C, 212°F
562143135 59 139 71°C, 160°F
Pure White (RAL9010)
562143165 74 165 100°C, 212°F
562144135 59 139 71°C, 160°F
Signal White (RAL9003)
562144165 74 165 100°C, 212°F
562145135 59 139 71°C, 160°F
Grey White (RAL9002)
562145165 74 165 100°C, 212°F
562146135 59 139 71°C, 160°F
Brown (RAL8028)
562146165 74 165 100°C, 212°F
562147135 59 139 71°C, 160°F
Black (RAL9005)
562147165 74 165 100°C, 212°F
562148135 59 139 71°C, 160°F
Brushed Brass
562148165 74 165 100°C, 212°F
562149135 59 139 71°C, 160°F
Brushed Chrome
562149165 74 165 100°C, 212°F
56214X135 59 139 71°C, 160°F
Custom Paint
56214X165 74 165 100°C, 212°F

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–129
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


WS™

Window Sprinklers, Horizontal & Pendent Vertical Sidewall


K Factor K= 80 (5.6)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, ULC, NYC, ICC

Temperature 68°C (155°F), 93°C (200°F)

Signal White Polyester, Chrome Plated, Natural Brass,


Sprinkler Finish
Jet Black

SIN TY3388, TY3488

Wrench Type W-Type 20

Tech Data Sheet TFP620

3 mm bulb • Only UL tested sprinklers that can protect glazing in a wall or window and allow it to maintain its mechanical
equivalent rating up to two hours • First sprinklers to be UL/C-UL Listed, ICC-ES, and ULC Listed & Approved for maintaining a rated
assembly • Pendent allows installation farther away from the glass than the sidewall • Sidewall permits the window mullion to act
as a baffle, allowing the sprinklers to be spaced closely together, if necessary • Provides the only UL tested option when seeking
wall fire ratings when using heat strengthened, tempered, or ceramic glass.

WS, K=80 (5.6), 1 ⁄ 2" NPT

Horizontal Sidewall • K=80 [5.6] Horizontal Sidewall - K=80 [5.6] • 1 ⁄ 2” NPT • TFP620
1
⁄ 2” NPT • SIN TY3388 Approvals &
Part No. Temp.
Finish Listings
Horizontal Sidewall Code
°C °F

UL
SIN TY3388
503051155 68 [155] 1 √
503051200 93 [200] 1 √
41,3 mm 503054155 68 [155] 4 √
(1-5/8") 503054200 93 [200] 4 √
503055155 68 [155] 5 √
503055200 93 [200] 5 √
503059155 68 [155] 9 √
54,0 mm 503059200 93 [200] 9 √
(2-1/8")

Vertical Sidewall • K=80 [5.6]


1
⁄ 2” NPT • SIN TY3488

Vertical Sidewall - K=80 [5.6] • 1 ⁄ 2” NPT • TFP620


52,4 mm
(2-1/16") Approvals &
Part No. Temp.
Finish Listings
Vertical Sidewall Code
°C °F
UL

SIN TY3488
503041155 68 [155] 1 √
503041200 93 [200] 1 √
54,0 mm 503044155 68 [155] 4 √
(2-1/8") 503044200 93 [200] 4 √
503045155 68 [155] 5 √
503045200 93 [200] 5 √
503049155 68 [155] 9 √
503049200 93 [200] 9 √

Finish Code: 1=Plain Brass, 4=Signal White Polyester RAL9003, 5=Jet Black Polyester RAL9005, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–130
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
CC1
Combustible Concealed Space Sprinklers™, Upright
K Factor K= 40 (2.8)
1
Thread Size ⁄2" NPT

Approvals UL

Temperature 79°C (175°F)

Sprinkler Finish Natural Brass

SIN TY1189

Wrench Type W-Type 20

Tech Data Sheet TFP630

3 mm bulb • Sprinklers are fast response, specific application sprinklers designed to provide protection of light hazard combustible,
as well as non-combustible, concealed spaces • Meets NFPA® Requirements for Specialty Listed Sprinklers in Combustible
Concealed Spaces • Allows the use of BlazeMaster® CPVC pipe with the benefit of superior sprinkler protection for wood
truss spaces.

CC1, K=40 (2.8), 1 ⁄ 2" NPT


K=40 [2.8] • 1 ⁄ 2” NPT • TFP630
Approvals &
27,0 mm Part No. Temp.
Finish Listings
(1-1/16")
Code
SIN TY1189 °C °F

UL
503001175 79 [175] 1 √

57,2 mm
(2-1/4")

Finish Code: 1=Plain Brass


Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–131
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


CC2
Combustible Concealed Space Sprinklers™, Upright
K Factor K= 60 (4.2), K= 80 (5.6)
1
Thread Size ⁄2" NPT

Approvals UL

Temperature 79°C (175°F)

Sprinkler Finish Natural Brass

SIN TY2189, TY3189

Wrench Type W-Type 6

Tech Data Sheet TFP632

3 mm bulb • Specific application sprinklers • Provides protection of specific light hazard combustible, as well as non-combustible,
concealed spaces requiring sprinkler protection • The CC2 Sprinklers comply with the criterion for the protection of combustible
concealed spaces as described in NFPA 13 • Allows the use of BlazeMaster® CPVC pipe in combustible concealed areas with the
benefit of superior sprinkler protection for wood truss spaces • Can be used on steel dry pipe sprinkler systems • Increased spacing
from 3,1m to 3,7m (10' to 12') • Increased coverage area from 9,3 m2 to 13,4 m2 (100 ft 2 to 144 ft 2)

CC2, K=60 (4.2) & 80 (5.6), 1 ⁄ 2" NPT


42,9 mm K=60 [4.2] & 80 [5.6] • 1 ⁄ 2” NPT • TFP632
(1-11/16") Approvals &
Temp.
Finish Listings
Part No. K-Factor SIN
Code
°C °F

UL
513111175 60 (4.2) TY2189 79 [175] 1 √
513011175 80 (5.6) TY3189 79 [175] 1 √
57,2 mm
(2-1/4")

Finish Code: 1=Plain Brass


Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–132
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
CC3
Combustible Concealed Space Sprinklers™, Upright
K Factor K= 60 (4.2), K= 80 (5.6)
1
Thread Size ⁄2" NPT

Approvals UL

Temperature 93°C (200°F)

Sprinkler Finish Natural Brass

SIN TY2199, TY3199

Wrench Type W-Type 6

Tech Data Sheet TFP633

3 mm bulb • The CC3 Combustible Concealed Sprinklers are quick response, upright, specific application sprinklers designed to
provide protection of specific light hazard combustible, as well as non-combustible, concealed spaces requiring protection • The
Model CC3 Sprinklers comply with the criteria for the protection of combustible concealed spaces as described in NFPA 13 • The
Model CC3 are designed for installation on BlazeMaster CPVC wet pipe systems and steel wet pipe or dry pipe sprinkler systems.

CC3, K=60 (4.2) & 80 (5.6), 1 ⁄ 2" NPT


K=60 [4.2] & 80 [5.6] • 1 ⁄ 2” NPT • TFP633
42,9 mm
Approvals &
(1-11/16") Temp.
Finish Listings
Part No. K-Factor SIN
Code
°C °F

UL
513111200 40 [4.2] TY2199 93 [200] 1 √
513011200 80 [5.6] TY3199 93 [200] 1 √
57,2 mm
(2-1/4")

Combustible Concealed Standard Spray


Sprinkler Discharge Pattern Sprinkler Discharge Pattern

Finish Code: 1=Plain Brass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–133
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


Issue D Quartzoid®
High Temperature, Upright & Pendent
K Factor K= 80 (5.6), K= 115 (8.0)
1
Thread Size ⁄2" NPT • 3 ⁄4" NPT

Approvals UL, C-UL, FM, LPCB

204°C (400°F), 260°C (500°F),


Temperature
343°C (650°F) (K=5.6 only)

Sprinkler Finish Natural Brass, Chrome Plated, Lead Coated

SIN TY3191, TY3296, TY4191, TY4292

Wrench Type W-Type 11

Tech Data Sheet TFP690

Standard coverage • All hazard • 11 mm bulb • Extra-high and ultra-high temperature ratings and corrosion resistant coatings •
Temperature Ratings to 343°C (650°F) available.

Issue D Quartzoid, K=80 (5.6) & 115 (8.0)

Upright • K=80 [5.6] (Shown) K=80 [5.6] • 1 ⁄ 2” NPT • TFP690


1
⁄ 2” NPT • SIN TY3191 Part No. Temp. Approvals & Listings
Finish
Upright Pendent

LPCB

FM
°C °F Code

UL
SIN TY3191 SIN TY3296

510361400 510401400 204 [400] 1 - √ √


510361500 510401500 260 [500] 1 √ √ √
74,6 mm 510361650 510401650 343 [650] 1 - √ -
(2-15/16") 510367400 510407400 204 [400] 7 - - √
510367500 510407500 260 [500] 7 - - √
510369400 510409400 204 [400] 9 - √ √
510369500 510409500 260 [500] 9 - √ √
510369650 510409650 343 [650] 9 - √ -

Pendent • K=80 [5.6] (Shown)


1
⁄ 2” NPT • SIN TY3296 K=115 [8.0] • 3 ⁄4” NPT • TFP690
Approvals &
Part No. Temp.
Listings
Finish
Upright Pendent Code
°C °F
UL

SIN TY4191 SIN TY4292

511361400 511401400 204 [400] 1 √


511361500 511401500 260 [500] 1 √
79,4 mm
511367400 511407400 204 [400] 7 √
(3-1/8")
511367500 511407500 260 [500] 7 √
511369400 511409400 204 [400] 9 √
511369500 511409500 260 [500] 9 √

Finish Code: 1=Plain Brass, 7=Lead Coated, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–134
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
TY-FRFS, TY-FS & TY-FS Special
Flat Spray, Upright & Pendent
K Factor K= 57 (4.0), K= 80 (5.6), & K=115 (8.0)

Thread Size ISO 7-R 3 ⁄ 8, 1 ⁄2" NPT • 3 ⁄4" NPT

Approvals VdS, LPCB

57°C (135°F), 68°C (155°F), 79°C (175°F),


Temperature
93°C (200°F), 141°C (286°F)

Sprinkler Finish Natural Brass

TY-FRFS:
TY1136, TY1236, TY3136, TY3236, TY4136, TY4236
TY-FS Special:
SIN
TY1146, TY1246, TY3146, TY3246, TY4146, TY4246
TY-FS:
TY1156, TY1256, TY3156, TY3256, TY4156, TY4256

Wrench Type W-Type 11

Tech Data Sheet TFP635

Standard coverage • All hazard • 3mm, 4mm or 5mm bulb • Extra-high and ultra-high temperature ratings and corrosion resistant
coatings • Temperature Ratings to 343°C (650°F) available.

K=57 (4.0), ISO 7-R 3 ⁄ 8

K=57 [4.0] • ISO 7-R 3 ⁄ 8 • TFP635


Upright • K=57 [4.0] Approvals &
Part No. SIN Temp.
ISO 7-R 3 ⁄ 8 Listings
Bulb Finish
Model
Size Code

LPCB
VKF
VdS
Upright Pendent Upright Pendent °C °F

CE
55 mm 513801135 513821135 57 [135] 1 √ √ √ √
513801155 513821155 68 [155] 1 √ √ √ √
513801175 513821175 TY-FRFS 3mm TY1136 TY1236 79 [175] 1 √ √ √ √
513801200 513821200 93 [200] 1 √ √ √ √
513801286 513821286 141 [286] 1 √ √ √ √
514801135 514821135 57 [135] 1 √ √ √ -
514801155 514821155 68 [155] 1 √ √ √ -
TY-FS
514801175 514821175 4mm TY1146 TY1246 79 [175] 1 √ √ √ -
Special
Pendent • K=57 [4.0] 514801200 514821200 93 [200] 1 √ √ √ -
ISO 7-R 3 ⁄ 8 514801286 514821286 141 [286] 1 √ √ √ -
515801135 515821135 57 [135] 1 √ √ √ √
515801155 515821155 68 [155] 1 √ √ √ √
515801175 515821175 TY-FS 5mm TY1156 TY1256 79 [175] 1 √ √ √ √
515801200 515821200 93 [200] 1 √ √ √ √
55 mm 515801286 515821286 141 [286] 1 √ √ √ √

Finish Code: 1=Plain Brass


Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–135
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


TY-FRFS, TY-FS & TY-FS Special
K=80 (5.6), 1 ⁄ 2" NPT

Upright • K=80 [5.6] K=80 [5.6] • 1 ⁄ 2" NPT • TFP635


1
⁄ 2" NPT Approvals &
Part No. SIN Temp.
Listings
Bulb Finish
Model
Size Code

LPCB
VKF
VdS
Upright Pendent Upright Pendent °C °F

CE
57 mm 513701135 513711135 57 [135] 1 √ √ √ √
513701155 513711155 68 [155] 1 √ √ √ √
513701175 513711175 TY-FRFS 3mm TY3136 TY3236 79 [175] 1 √ √ √ √
513701200 513711200 93 [200] 1 √ √ √ √
513701286 513711286 141 [286] 1 √ √ √ √
514701135 514711135 57 [135] 1 √ √ √ -
Pendent • K=80 [5.6] 514701155 514711155 68 [155] 1 √ √ √ -
1
⁄ 2" NPT TY-FS
514701175 514711175 4mm TY3146 TY3246 79 [175] 1 √ √ √ -
Special
514701200 514711200 93 [200] 1 √ √ √ -
514701286 514711286 141 [286] 1 √ √ √ -
515701135 515711135 57 [135] 1 √ √ √ √
515701155 515711155 68 [155] 1 √ √ √ √
57 mm 515701175 515711175 TY-FS 5mm TY3156 TY3256 79 [175] 1 √ √ √ √
515701200 515711200 93 [200] 1 √ √ √ √
515701286 515711286 141 [286] 1 √ √ √ √

K=115 (8.0), 3 ⁄4" NPT

Upright • K=115 [8.0] K=115 [8.0] • 3 ⁄4" NPT • TFP635


3
⁄4" NPT Approvals &
Part No. SIN Temp.
Listings
Bulb Finish
Model
Size Code

LPCB
VKF
VdS

Upright Pendent Upright Pendent °C °F


CE

60 mm
513901135 513911135 57 [135] 1 √ √ √ √
513901155 513911155 68 [155] 1 √ √ √ √
513901175 513911175 TY-FRFS 3mm TY4136 TY4236 79 [175] 1 √ √ √ √
513901200 513911200 93 [200] 1 √ √ √ √
513901286 513911286 141 [286] 1 √ √ √ √
514901135 514911135 57 [135] 1 √ √ √ -
Pendent • K=115 [8.0] 514901155 514911155 68 [155] 1 √ √ √ -
3
⁄4" NPT TY-FS
514901175 514911175 4mm TY4146 TY4246 79 [175] 1 √ √ √ -
Special
514901200 514911200 93 [200] 1 √ √ √ -
514901286 514911286 141 [286] 1 √ √ √ -
515901135 515911135 57 [135] 1 √ √ √ √
515901155 515911155 68 [155] 1 √ √ √ √
60 mm 515901175 515911175 TY-FS 5mm TY4156 TY4256 79 [175] 1 √ √ √ √
515901200 515911200 93 [200] 1 √ √ √ √
515901286 515911286 141 [286] 1 √ √ √ √

Finish Code: 1=Plain Brass


Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–136
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
TY-B
Conventional Sprinklers, Special Response
K Factor K= 80 & 115
1
Thread Size ⁄2" NPT • 3 ⁄4" NPT

Approvals VdS

57°C (135°F), 68°C (155°F), 79°C (175°F),


Temperature
93°C (200°F), 141°C (286°F)

Natural Brass, Pure White, Signal White,


Sprinkler Finish
Chrome Plated

SIN TY3641, TY4641

Wrench Type W-Type 6, W-Type 7 (Recessed)

Tech Data Sheet TFP663

Standard coverage • 4 mm bulb • Produces a spherical water discharge pattern with approximately 50% of the discharge directed
upwards and approximately 50% of the discharge directed downwards. • These sprinklers are intended to be installed either
pendent or upright, and in either position

TY-B, K=80, 1 ⁄ 2" NPT


K=80 • 1 ⁄ 2” NPT • TFP663
Part No. Temp. Approvals & Listings
Upright or Pendent • K=80
1
⁄ 2" NPT Finish
Conventional

VKF
VdS
°C °F Code

CE
SIN TY3641

574731135 57 135 1 √ √ √
574731155 68 155 1 √ √ √
574731175 79 175 1 √ √ √
56 mm 574731200 93 200 1 √ √ √
574731286 141 286 1 √ √ √
574733135 57 135 3 √ √ √
574733155 68 155 3 √ √ √
574733175 79 175 3 √ √ √
574733200 93 200 3 √ √ √
574733286 141 286 3 √ √ √
574734135 57 135 4 √ √ √
574734155 68 155 4 √ √ √
574734175 79 175 4 √ √ √
574734200 93 200 4 √ √ √
574734286 141 286 4 √ √ √
574739135 57 135 9 √ √ √
574739155 68 155 9 √ √ √
574739175 79 175 9 √ √ √
574739200 93 200 9 √ √ √
574739286 141 286 9 √ √ √

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–137
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


TY-B

TY-B, K=115, 3 ⁄4" NPT


K=115 • 3 ⁄4” NPT • TFP663
Part No. Temp. Approvals & Listings
Upright or Pendent • K=115
3
⁄4" NPT Finish
Conventional

VKF
VdS
°C °F Code

CE
SIN TY4641

574931135 57 135 1 √ √ √
574931155 68 155 1 √ √ √
574931175 79 175 1 √ √ √
57 mm 574931200 93 200 1 √ √ √
574931286 141 286 1 √ √ √
574933135 57 135 3 √ √ √
574933155 68 155 3 √ √ √
574933175 79 175 3 √ √ √
574933200 93 200 3 √ √ √
574933286 141 286 3 √ √ √
574934135 57 135 4 √ √ √
574934155 68 155 4 √ √ √
574934175 79 175 4 √ √ √
574934200 93 200 4 √ √ √
574934286 141 286 4 √ √ √
574939135 57 135 9 √ √ √
574939155 68 155 9 √ √ √
574939175 79 175 9 √ √ √
574939200 93 200 9 √ √ √
574939286 141 286 9 √ √ √

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–138
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
TY-B

Conventional (Old Style)


K Factor K= 80 (5.6), K= 115 (8.0)
1
Thread Size ⁄2" NPT • 3 ⁄4" NPT

Approvals UL, C-UL, LPCB, VdS, NYC

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F), 182°C (360°F), Open (K=115)

Natural Brass, Chrome Plated, Pure White,


Sprinkler Finish Signal White, Wax Coated, Lead Coated,
Wax Over Lead Coated

SIN TY3651, TY4651

Wrench Type W-Type 6

Tech Data Sheet TFP661

Ordinary and Extra High Hazard • 5 mm bulb • These sprinklers are intended to be installed either pendent or upright, and in
either position, they produce a spherical water discharge pattern with approximately 50% of the discharge directed upwards and
approximately 50% of the discharge directed downwards. • The NFPA permits the use of “Old Style Sprinklers” where special
construction features require a unique water distribution.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–139
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


TY-B

TY-B, K=80 (5.6), 1 ⁄ 2" NPT K=80 [5.6] • 1 ⁄ 2” NPT • TFP661


Part No. Temperature Approvals & Listings

Academy of
Upright or Pendent • K=80 [5.6]

Belarusian
Ukrainian
Finish

Russia
1
⁄ 2” NPT • SIN TY3651

LPCB

MED

SAS

VKF
VdS

Fire
SIN TY3651 °C °F Code

UL
CE
575601135 57 135 1 √ √ √ √ √ √ √ √ √ √
575601155 68 155 1 √ √ √ √ √ √ √ √ √ √
55,6 mm 575601175 79 175 1 √ √ √ √ √ √ √ √ √ √
(2-3/16") 575601200 93 200 1 √ √ √ √ √ √ √ √ √ √
575601286 141 286 1 √ √ √ √ √ √ √ √ √ √
575601360 182 360 1 √ √ √ √ √ √ √ √ √ √
575603135 57 135 3 √ √ √ √ √ √ √ √ √ √
575603155 68 155 3 √ √ √ √ √ √ √ √ √ √
575603175 79 175 3 √ √ √ √ √ √ √ √ √ √
575603200 93 200 3 √ √ √ √ √ √ √ √ √ √
575603286 141 286 3 √ √ √ √ √ √ √ √ √ √
575603360 182 360 3 √ √ √ √ √ √ √ √ √ √
575604135 57 135 4 √ √ √ √ √ √ √ √ √ √
575604155 68 155 4 √ √ √ √ √ √ √ √ √ √
575604175 79 175 4 √ √ √ √ √ √ √ √ √ √
575604200 93 200 4 √ √ √ √ √ √ √ √ √ √
575604286 141 286 4 √ √ √ √ √ √ √ √ √ √
575604360 182 360 4 √ √ √ √ √ √ √ √ √ √
575606135 57 135 6 - - √ √ √ √ √ √ √ √
575606155 68 155 6 - - √ √ √ √ √ √ √ √
575606175 79 175 6 - - √ √ √ √ √ √ √ √
575606200 93 200 6 - - √ √ √ √ √ √ √ √
575606286 141 286 6 - - √ √ √ √ √ √ √ √
575607135 57 135 7 - - √ √ √ √ √ √ √ √
575607155 68 155 7 - - √ √ √ √ √ √ √ √
575607175 79 175 7 - - √ √ √ √ √ √ √ √
575607200 93 200 7 - - √ √ √ √ √ √ √ √
575607286 141 286 7 - - √ √ √ √ √ √ √ √
575607360 182 360 7 - - √ √ √ √ √ √ √ √
575608135 57 135 8 - - √ √ √ √ √ √ √ √
575608155 68 155 8 - - √ √ √ √ √ √ √ √
575608175 79 175 8 - - √ √ √ √ √ √ √ √
575608200 93 200 8 - - √ √ √ √ √ √ √ √
575608286 141 286 8 - - √ √ √ √ √ √ √ √
575609135 57 135 9 √ √ √ √ √ √ √ √ √ √
575609155 68 155 9 √ √ √ √ √ √ √ √ √ √
575609175 79 175 9 √ √ √ √ √ √ √ √ √ √
575609200 93 200 9 √ √ √ √ √ √ √ √ √ √
575609286 141 286 9 √ √ √ √ √ √ √ √ √ √
575609360 182 360 9 √ √ √ √ √ √ √ √ √ √

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003,
6=Wax Coated, 7=Lead Coated, 8=Wax-Over Lead Coated, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–140
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
TY-B

TY-B, K=115 (8.0), 3 ⁄4" NPT K=115 [8.0] • 3 ⁄4” NPT • TFP661
Part No. Temp. Approvals & Listings

Belarusian
Upright or Pendent • K=115 [8.0]

Ukrainian

Academy
of Russia
Finish

LPCB

MED
3
⁄4” NPT • SIN TY4651

SAS

VKF
VdS

Fire
SIN TY4651 °C °F Code

UL
CE
575931135 57 135 1 √ √ √ √ √ √ √ √ √ √
575931155 68 155 1 √ √ √ √ √ √ √ √ √ √
575931175 79 175 1 √ √ √ √ √ √ √ √ √ √
57,2 mm
575931200 93 200 1 √ √ √ √ √ √ √ √ √ √
(2-1/4")
575931286 141 286 1 √ √ √ √ √ √ √ √ √ √
575931360 182 360 1 √ √ √ √ √ √ √ √ √ √
575931000 Open 1 - - √ √ √ √ √ √ √
575933135 57 135 3 √ √ √ √ √ √ √ √ √ √
575933155 68 155 3 √ √ √ √ √ √ √ √ √ √
575933175 79 175 3 √ √ √ √ √ √ √ √ √ √
575933200 93 200 3 √ √ √ √ √ √ √ √ √ √
575933286 141 286 3 √ √ √ √ √ √ √ √ √ √
575933360 182 360 3 √ √ √ √ √ √ √ √ √ √
575933000 Open 3 - - √ √ √ √ √ √ √
575934135 57 135 4 √ √ √ √ √ √ √ √ √ √
575934155 68 155 4 √ √ √ √ √ √ √ √ √ √
575934175 79 175 4 √ √ √ √ √ √ √ √ √ √
575934200 93 200 4 √ √ √ √ √ √ √ √ √ √
575934286 141 286 4 √ √ √ √ √ √ √ √ √ √
575934360 182 360 4 √ √ √ √ √ √ √ √ √ √
575934000 Open 4 - - √ √ √ √ √ √ √
575936135 57 135 6 - - √ √ √ √ √ √ √ √
575936155 68 155 6 - - √ √ √ √ √ √ √ √
575936175 79 175 6 - - √ √ √ √ √ √ √ √
575936200 93 200 6 - - √ √ √ √ √ √ √ √
575936286 141 286 6 - - √ √ √ √ √ √ √ √
575937135 57 135 7 - - √ √ √ √ √ √ √ √
575937155 68 155 7 - - √ √ √ √ √ √ √ √
575937175 79 175 7 - - √ √ √ √ √ √ √ √
575937200 93 200 7 - - √ √ √ √ √ √ √ √
575937286 141 286 7 - - √ √ √ √ √ √ √ √
575937360 182 360 7 - - √ √ √ √ √ √ √ √
575937000 Open 7 - - √ √ √ √ √ √ √
575938135 57 135 8 - - √ √ √ √ √ √ √ √
575938155 68 155 8 - - √ √ √ √ √ √ √ √
575938175 79 175 8 - - √ √ √ √ √ √ √ √
575938200 93 200 8 - - √ √ √ √ √ √ √ √
575938286 141 286 8 - - √ √ √ √ √ √ √ √
575939135 57 135 9 √ √ √ √ √ √ √ √ √ √
575939155 68 155 9 √ √ √ √ √ √ √ √ √ √
575939175 79 175 9 √ √ √ √ √ √ √ √ √ √
575939200 93 200 9 √ √ √ √ √ √ √ √ √ √
575939286 141 286 9 √ √ √ √ √ √ √ √ √ √
575939360 182 360 9 √ √ √ √ √ √ √ √ √ √
575939000 Open 9 - - √ √ √ √ √ √ √

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003,
6=Wax Coated, 7=Lead Coated, 8=Wax-Over Lead Coated, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–141
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


TY-B
Conventional (Old Style)
K Factor K= 80 (5.6)
1
Thread Size ⁄2" NPT

TY365: UL, VdS,


Approvals
TY3650: LPCB

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F), 182°C (360°F)

Natural Brass, Chrome Plated, Pure White,


Sprinkler Finish
Signal White

SIN TY365, TY3650

Wrench Type W-Type 6

Tech Data Sheet TFP662

Ordinary and Extra High Hazard • 5 mm bulb • These sprinklers are intended to be installed either pendent or upright, and in
either position, they produce a spherical water discharge pattern with approximately 50% of the discharge directed upwards and
approximately 50% of the discharge directed downwards.

TY-B, K=80 (5.6), 1 ⁄ 2" NPT


K=80 [5.6] • 1 ⁄ 2” NPT • TFP662
Part No. Temp. Approvals & Listings
Upright or Pendent • K=80 [5.6]

Belarusian
Ukrainian

Academy
of Russia
1
⁄ 2” NPT • SIN TY365 LPCB Finish
TY3650
LPCB

VKF
VdS

Fire
SIN TY365 Approved °C °F Code
SIN TY3650 CE

775731135 775731135-L 57 135 1 √ √ √ √ √ √ √


775731155 775731155-L 68 155 1 √ √ √ √ √ √ √
50,8 mm 775731175 775731175-L 79 175 1 √ √ √ √ √ √ √
(2") 775731200 775731200-L 93 200 1 √ √ √ √ √ √ √
775731286 775731286-L 141 286 1 √ √ √ √ √ √ √
775731360 775731360-L 182 360 1 √ √ √ √ √ √ √
775733135 775733135-L 57 135 3 √ √ √ √ √ √ √
775733155 775733155-L 68 155 3 √ √ √ √ √ √ √
775733175 775733175-L 79 175 3 √ √ √ √ √ √ √
775733200 775733200-L 93 200 3 √ √ √ √ √ √ √
775733286 775733286-L 141 286 3 √ √ √ √ √ √ √
775733360 775733360-L 182 360 3 √ √ √ √ √ √ √
775734135 775734135-L 57 135 4 √ √ √ √ √ √ √
775734155 775734155-L 68 155 4 √ √ √ √ √ √ √
775734175 775734175-L 79 175 4 √ √ √ √ √ √ √
775734200 775734200-L 93 200 4 √ √ √ √ √ √ √
775734286 775734286-L 141 286 4 √ √ √ √ √ √ √
775734360 775734360-L 182 360 4 √ √ √ √ √ √ √
775739135 775739135-L 57 135 9 √ √ √ √ √ √ √
775739155 775739155-L 68 155 9 √ √ √ √ √ √ √
775739175 775739175-L 79 175 9 √ √ √ √ √ √ √
775739200 775739200-L 93 200 9 √ √ √ √ √ √ √
775739286 775739286-L 141 286 9 √ √ √ √ √ √ √
775739360 775739360-L 182 360 9 √ √ √ √ √ √ √
Use suffix “I” for ISO 7-1 connection; for example, 77-573-4-175-I
LPCB approved Series TY-B Conventional Sprinkler assemblies only: Use sufix “L” for LPCB
Approved assemblies (e.g., 77-573-4-175-L or 77-573-4-175-IL for LPCB Approved and
ISO 7-1 connection)

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–142
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
TY-FRB

Conventional (Old Style)


K Factor K= 80 (5.6), K= 115 (8.0)
1
Thread Size ⁄2" NPT • 3 ⁄4" NPT

Approvals UL, C-UL, LPCB, VdS, NYC

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F)

Natural Brass, Chrome Plated, Pure White,


Sprinkler Finish
Signal White, Jet Black, Lead Coated

SIN TY3631, TY4631

Wrench Type W-Type 6

Tech Data Sheet TFP666

Ordinary and Extra High Hazard • 3 mm bulb • These sprinklers are intended to be installed either pendent or upright, and in
either position, they produce a spherical water discharge pattern with approximately 50% of the discharge directed upwards and
approximately 50% of the discharge directed downwards.

TY-FRB, K=80 (5.6), 1 ⁄ 2" NPT K=80 [5.6] • 1 ⁄ 2” NPT • TFP666


Part No. Temperature Approvals & Listings

Ukrainian
Upright or Pendent • K=80 [5.6]

Academy
of Russia
Finish

MED
1

SAS
⁄ 2” NPT • SIN TY3631

VKF
VdS

Fire
FM

SIN TY3631 °C °F Code UL

CE
573731135 57 135 1 √ √ √ √ √ √ √ √ √
573731155 68 155 1 √ √ √ √ √ √ √ √ √
573731175 79 175 1 √ √ √ √ √ √ √ √ √
55,6 mm
573731200 93 200 1 √ √ √ √ √ √ √ √ √
(2-3/16")
573731286 141 286 1 √ √ √ √ √ √ √ √ √
573731360 182 360 1 √ √ √ √ √ √ √ √ √
573733135 57 135 3 √ √ √ √ √ √ √ √ √
573733155 68 155 3 √ √ √ √ √ √ √ √ √
573733175 79 175 3 √ √ √ √ √ √ √ √ √
573733200 93 200 3 √ √ √ √ √ √ √ √ √
573733286 141 286 3 √ √ √ √ √ √ √ √ √
573733360 182 360 3 √ √ √ √ √ √ √ √ √
573734135 57 135 4 √ √ √ √ √ √ √ √ √
573734155 68 155 4 √ √ √ √ √ √ √ √ √
573734175 79 175 4 √ √ √ √ √ √ √ √ √
573734200 93 200 4 √ √ √ √ √ √ √ √ √
573734286 141 286 4 √ √ √ √ √ √ √ √ √
573734360 182 360 4 √ √ √ √ √ √ √ √ √
573736155 68 155 5 √ √ √ √ √ √ √ √ √
573736200 93 200 5 √ √ √ √ √ √ √ √ √
573737135 57 135 7 - - √ √ √ √ √ √ √
573737155 68 155 7 - - √ √ √ √ √ √ √
573737175 79 175 7 - - √ √ √ √ √ √ √
573737200 93 200 7 - - √ √ √ √ √ √ √
573737286 141 286 7 - - √ √ √ √ √ √ √
573737360 182 360 7 - - √ √ √ √ √ √ √
573739135 57 135 9 √ √ √ √ √ √ √ √ √
573739155 68 155 9 √ √ √ √ √ √ √ √ √
573739175 79 175 9 √ √ √ √ √ √ √ √ √
573739200 93 200 9 √ √ √ √ √ √ √ √ √
573739286 141 286 9 √ √ √ √ √ √ √ √ √
573739360 182 360 9 √ √ √ √ √ √ √ √ √

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003,
5=Jet Black Polyester RAL9005, 7=Lead Coated, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–143
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


TY-FRB

TY-FRB, K=115 (8.0), 3 ⁄4" NPT K=115 [8.0] • 3 ⁄4” NPT • TFP666
Part No. Temperature Approvals & Listings

Ukrainian

Academy
of Russia
Upright or Pendent • K=115 [8.0] Finish

MED

SAS

VKF
VdS

Fire
3
⁄4” NPT • SIN TY4631

FM
SIN TY4631 °C °F Code

UL

CE
573731135 57 135 1 √ √ √ √ √ √ √ √ √
573731155 68 155 1 √ √ √ √ √ √ √ √ √
573731175 79 175 1 √ √ √ √ √ √ √ √ √
57,2 mm 573731200 93 200 1 √ √ √ √ √ √ √ √ √
(2-1/4") 573731286 141 286 1 √ √ √ √ √ √ √ √ √
573733135 57 135 3 √ √ √ √ √ √ √ √ √
573733155 68 155 3 √ √ √ √ √ √ √ √ √
573733175 79 175 3 √ √ √ √ √ √ √ √ √
573733200 93 200 3 √ √ √ √ √ √ √ √ √
573733286 141 286 3 √ √ √ √ √ √ √ √ √
573734135 57 135 4 √ √ √ √ √ √ √ √ √
573734155 68 155 4 √ √ √ √ √ √ √ √ √
573734175 79 175 4 √ √ √ √ √ √ √ √ √
573734200 93 200 4 √ √ √ √ √ √ √ √ √
573734286 141 286 4 √ √ √ √ √ √ √ √ √
573736155 68 155 5 √ √ √ √ √ √ √ √ √
573736200 93 200 5 √ √ √ √ √ √ √ √ √
573737135 57 135 7 - - √ √ √ √ √ √ √
573737155 68 155 7 - - √ √ √ √ √ √ √
573737175 79 175 7 - - √ √ √ √ √ √ √
573737200 93 200 7 - - √ √ √ √ √ √ √
573737286 141 286 7 - - √ √ √ √ √ √ √
573739135 57 135 9 √ √ √ √ √ √ √ √ √
573739155 68 155 9 √ √ √ √ √ √ √ √ √
573739175 79 175 9 √ √ √ √ √ √ √ √ √
573739200 93 200 9 √ √ √ √ √ √ √ √ √
573739286 141 286 9 √ √ √ √ √ √ √ √ √

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003,
5=Jet Black Polyester RAL9005, 7=Lead Coated, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–144
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
TY-FRB
Conventional (Old Style)
K Factor K= 80 (5.6)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, VdS, LPCB (TY3630 Only)

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F)

Natural Brass, Chrome Plated, Pure White,


Sprinkler Finish
Signal White

SIN TY363, TY3630

Wrench Type W-Type 6

Tech Data Sheet TFP667

Ordinary and Extra High Hazard • The TYCO Series TY-FRB, Conventional Sprinklers, are quick response, standard coverage,
decorative 3 mm glass bulb type spray sprinklers • These sprinklers are intended to be installed either pendent or upright, and in
either position, they produce a spherical water discharge pattern with approximately 50% of the discharge directed upwards and
approximately 50% of the discharge directed downwards.

TY-FRB, K=80 (5.6), 1 ⁄ 2" NPT K=80 [5.6] • 1 ⁄ 2” NPT • TFP667


Part No. Temp. Approvals & Listings
Upright or Pendent • K=80 [5.6]

Belarusian
Ukrainian

Academy
of Russia
LPCB Finish

TY3650
1
⁄ 2” NPT • SIN TY363
LPCB

VKF
VdS

Fire
SIN TY363 Approved °C °F Code UL

CE
SIN TY3630

773731135 773731135-L 57 135 1 √ √ √ √ √ √ √ √


773731155 773731155-L 68 155 1 √ √ √ √ √ √ √ √
773731175 773731175-L 79 175 1 √ √ √ √ √ √ √ √
50,8 mm 773731200 773731200-L 93 200 1 √ √ √ √ √ √ √ √
(2") 773731286 773731286-L 141 286 1 √ √ √ √ √ √ √ √
773733135 773733135-L 57 135 3 √ √ √ √ √ √ √ √
773733155 773733155-L 68 155 3 √ √ √ √ √ √ √ √
773733175 773733175-L 79 175 3 √ √ √ √ √ √ √ √
773733200 773733200-L 93 200 3 √ √ √ √ √ √ √ √
773733286 773733286-L 141 286 3 √ √ √ √ √ √ √ √
773734135 773734135-L 57 135 4 √ √ √ √ √ √ √ √
773734155 773734155-L 68 155 4 √ √ √ √ √ √ √ √
773734175 773734175-L 79 175 4 √ √ √ √ √ √ √ √
773734200 773734200-L 93 200 4 √ √ √ √ √ √ √ √
773734286 773734286-L 141 286 4 √ √ √ √ √ √ √ √
773739135 773739135-L 57 135 9 √ √ √ √ √ √ √ √
773739155 773739155-L 68 155 9 √ √ √ √ √ √ √ √
773739175 773739175-L 79 175 9 √ √ √ √ √ √ √ √
773739200 773739200-L 93 200 9 √ √ √ √ √ √ √ √
773739286 773739286-L 141 286 9 √ √ √ √ √ √ √ √
Use suffix “I” for ISO 7-1 connection; for example, 77-373-4-175-I
LPCB approved Series TY-B Conventional Sprinkler assemblies only: Use sufix “L” for LPCB
Approved assemblies (e.g., 77-373-4-175-L or 77-373-4-175-IL for LPCB Approved and
ISO 7-1 connection)

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–145
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


TY-B & TY-FRB
Upright, Pendent & Recessed Pendent
K Factor K= 58

Thread Size ISO 7-R3 ⁄ 8

Approvals VdS, LPCB

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F), 5mm Bulb - 182°C (360°F)

Natural Brass, Chrome Plated, Pure White,


Sprinkler Finish
Signal White

SIN TY2108, TY2208,TY2109, TY2209

Wrench Type W-Type 6 & W-Type 7 (Recessed)

Tech Data Sheet TFP670

The TYCO Series TY-B (5 mm Bulb) and TY-FRB (3 mm Bulb) • 10 mm orifice Upright and Pendent Sprinklers • Both the Upright and
Pendent Sprinklers produce a hemispherical water distribution pattern below the deflector.

TY-B, K=58, ISO 7-R 3 ⁄ 8 K=58 • ISO 7-R 3 ⁄ 8 • TFP670


Part No. 5mm Bulb Temp. Approvals & Listings
Upright • K=58
ISO 7-R 3 ⁄ 8 • SIN TY2108 Finish
Upright Pendent

LPCB

MED

SAS

VKF
°C °F Code VdS

CE
SIN TY2108 SIN TY2208

575801135 575811135 57 135 1  √ √ √ √ √


575801155 575811155 68 155 1  √ √ √ √ √
575801175 575811175 79 175 1  √ √ √ √ √
53 mm 575801200 575811200 93 200 1  √ √ √ √ √
575801286 575811286 141 286 1  √ √ √ √ √
575801360 575811360 182 360 1  √ √ √ √ √
575803135 575813135 57 135 3  √ √ √ √ √
575803155 575813155 68 155 3  √ √ √ √ √
575803175 575813175 79 175 3  √ √ √ √ √
Pendent • K=58 575803200 575813200 93 200 3  √ √ √ √ √
ISO 7-R 3 ⁄ 8 • SIN TY2208 575803286 575813286 141 286 3  √ √ √ √ √
575803360 575813360 182 360 3  √ √ √ √ √
575804135 575814135 57 135 4  √ √ √ √ √
575804155 575814155 68 155 4  √ √ √ √ √
575804175 575814175 79 175 4  √ √ √ √ √
575804200 575814200 93 200 4  √ √ √ √ √
55 mm
575804286 575814286 141 286 4  √ √ √ √ √
575804360 575814360 182 360 4  √ √ √ √ √
575809135 575819135 57 135 9  √ √ √ √ √
575809155 575819155 68 155 9  √ √ √ √ √
575809175 575819175 79 175 9  √ √ √ √ √
575809200 575819200 93 200 9  √ √ √ √ √
575809286 575819286 141 286 9  √ √ √ √ √
575809360 575819360 182 360 9  √ √ √ √ √
√=Both Approved, =Recessed Pendent Not Approved

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 9=Chrome Plated

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–146
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
TY-B & TY-FRB

TY-FRB, K=58, ISO 7-R 3 ⁄ 8 K=58 • ISO 7-R 3 ⁄ 8 • TFP670


Part No. 3mm Bulb Temp. Approvals & Listings
Upright • K=58
ISO 7-R 3 ⁄ 8 • SIN TY2109 Finish
Upright Pendent

LPCB

MED

SAS

VKF
VdS
°C °F Code

CE
SIN TY2109 SIN TY2209

573801135 573811135 57 135 1  √ √ √ √ √


573801155 573811155 68 155 1  √ √ √ √ √
573801175 573811175 79 175 1  √ √ √ √ √
53 mm 573801200 573811200 93 200 1  √ √ √ √ √
573801286 573811286 141 286 1  √ √ √ √ √
573803135 573813135 57 135 3  √ √ √ √ √
573803155 573813155 68 155 3  √ √ √ √ √
573803175 573813175 79 175 3  √ √ √ √ √
573803200 573813200 93 200 3  √ √ √ √ √
Pendent • K=58 573803286 573813286 141 286 3  √ √ √ √ √
ISO 7-R 3 ⁄ 8 • SIN TY2209 573804135 573814135 57 135 4  √ √ √ √ √
573804155 573814155 68 155 4  √ √ √ √ √
573804175 573814175 79 175 4  √ √ √ √ √
573804200 573814200 93 200 4  √ √ √ √ √
573804286 573814286 141 286 4  √ √ √ √ √
573809135 573819135 57 135 9  √ √ √ √ √
55 mm
573809155 573819155 68 155 9  √ √ √ √ √
573809175 573819175 79 175 9  √ √ √ √ √
573809200 573819200 93 200 9  √ √ √ √ √
573809286 573819286 141 286 9  √ √ √ √ √
√=Both Approved, =Recessed Pendent Not Approved

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–147
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


TY-B
Upright, & Pendent, Special Response
K Factor K= 57, 80, 115

Thread Size ISO 7-R3 ⁄ 8, 1 ⁄ 2" NPT, 3 ⁄4" NPT

Approvals VdS, LPCB

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F)

Natural Brass, Chrome Plated, Pure White,


Sprinkler Finish
Signal White

SIN TY2149, TY2249, TY3141, TY3241, TY4141, TY4241

Wrench Type W-Type 6 & W-Type 7 (Recessed)

Tech Data Sheet TFP672

Upright and Pendent Sprinklers described in this data sheet are special response - standard coverage • Decorative 4 mm glass bulb
type spray sprinklers designed for use in accordance with the installation rules recognised by the applicable Approval agency.

TY-B, K=57, ISO 7-R 3 ⁄ 8 K=57 • ISO 7-R 3 ⁄ 8 • TFP672


Part No. Temp. Approvals & Listings
Upright • K=57
ISO 7-R 3 ⁄ 8 • SIN TY2149 Finish
Upright Pendent

VKF
VdS
°C °F Code

CE
SIN TY2149 SIN TY2249

574801135 574811135 57 135 1 √ √ √


574801155 574811155 68 155 1 √ √ √
574801175 574811175 79 175 1 √ √ √
53 mm
574801200 574811200 93 200 1 √ √ √
574801286 574811286 141 286 1 √ √ √
574803135 574813135 57 135 3 √ √ √
574803155 574813155 68 155 3 √ √ √
574803175 574813175 79 175 3 √ √ √
574803200 574813200 93 200 3 √ √ √
Pendent • K=57 574803286 574813286 141 286 3 √ √ √
ISO 7-R 3 ⁄ 8 • SIN TY2149 574804135 574814135 57 135 4 √ √ √
574804155 574814155 68 155 4 √ √ √
574804175 574814175 79 175 4 √ √ √
574804200 574814200 93 200 4 √ √ √
574804286 574814286 141 286 4 √ √ √
574809135 574819135 57 135 9 √ √ √
55 mm 574809155 574819155 68 155 9 √ √ √
574809175 574819175 79 175 9 √ √ √
574809200 574819200 93 200 9 √ √ √
574809286 574819286 141 286 9 √ √ √

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–148
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
TY-B

TY-B, K=80, 1 ⁄ 2" NPT K=80 • 1 ⁄ 2" NPT • TFP672


Part No. Temp. Approvals & Listings
Upright • K=80
Finish
1
⁄ 2" NPT • SIN TY3141 Upright Pendent

VKF
VdS
°C °F Code

CE
SIN TY3141 SIN TY3241

574701135 574711135 57 135 1 √ √ √


574701155 574711155 68 155 1 √ √ √
574701175 574711175 79 175 1 √ √ √
56 mm 574701200 574711200 93 200 1 √ √ √
574701286 574711286 141 286 1 √ √ √
574703135 574713135 57 135 3 √ √ √
574703155 574713155 68 155 3 √ √ √
574703175 574713175 79 175 3 √ √ √
574703200 574713200 93 200 3 √ √ √
574703286 574713286 141 286 3 √ √ √
Pendent • K=80
1 574704135 574714135 57 135 4 √ √ √
⁄ 2" NPT • SIN TY3241
574704155 574714155 68 155 4 √ √ √
574704175 574714175 79 175 4 √ √ √
574704200 574714200 93 200 4 √ √ √
574704286 574714286 141 286 4 √ √ √
574709135 574719135 57 135 9 √ √ √
56 mm 574709155 574719155 68 155 9 √ √ √
574709175 574719175 79 175 9 √ √ √
574709200 574719200 93 200 9 √ √ √
574709286 574719286 141 286 9 √ √ √

TY-B, K=115, 3 ⁄4" NPT K=115 • 3 ⁄4" NPT • TFP672


Part No. Temp. Approvals & Listings
Upright • K=115
Finish
3
⁄4" NPT • SIN TY4141 Upright Pendent

VKF
VdS
°C °F Code

CE
SIN TY4141 SIN TY4241

574901135 574911135 57 135 1 √ √ √


574901155 574911155 68 155 1 √ √ √
574901175 574911175 79 175 1 √ √ √
57 mm 574901200 574911200 93 200 1 √ √ √
574901286 574911286 141 286 1 √ √ √
574903135 574913135 57 135 3 √ √ √
574903155 574913155 68 155 3 √ √ √
574903175 574913175 79 175 3 √ √ √
574903200 574913200 93 200 3 √ √ √
574903286 574913286 141 286 3 √ √ √
Pendent • K=115
3 574904135 574914135 57 135 4 √ √ √
⁄4" NPT • SIN TY4241
574904155 574914155 68 155 4 √ √ √
574904175 574914175 79 175 4 √ √ √
574904200 574914200 93 200 4 √ √ √
574904286 574914286 141 286 4 √ √ √
574909135 574919135 57 135 9 √ √ √
574909155 574919155 68 155 9 √ √ √
59 mm
574909175 574919175 79 175 9 √ √ √
574909200 574919200 93 200 9 √ √ √
574909286 574919286 141 286 9 √ √ √

Finish Code: 1=Plain Brass, 3=Pure White Polyester RAL9010, 4=Signal White Polyester RAL9003, 9=Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–149
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


FTR-1
Fixed Temperature Release
K Factor K= 80 (5.6)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL

Temperature 57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F)

Natural Brass, White Polyester Coated,


Sprinkler Finish
Grey TEFLON Coated

SIN TY3030

Wrench Type W-Type 6

Tech Data Sheet TFP1388

3 mm bulb • Fixed-temperature, heat detector intended for wet or dry pilot release service • Maximum 12.2 x 12.2m (40' x 40')
spacing • Can be used for pilot line service, instead of standard sprinklers, to activate deluge and preaction systems equipped with
either wet or dry pilot line detection • Corrosion resistant assembly option for outdoor applications (TEFLON coated)

FTR-1, K=80 (5.6), 1 ⁄ 2" NPT K=80 [5.6] • 1 ⁄ 2” NPT • TFP1388


Approvals &
Part No. Temperature
Upright or Pendent • K=80 [5.6] Listings
1
⁄ 2” NPT • SIN TY3030 Finish
Code
SIN TY3030 °C °F

UL
510411135 57 135 1 √
510411155 68 155 1 √
510411175 79 175 1 √
55,6 mm 510411200 93 200 1 √
(2-3/16") 510413135 57 135 3 √
510413155 68 155 3 √
510413175 79 175 3 √
510413200 93 200 3 √
510414135 57 135 4 √
510414155 68 155 4 √
510414175 79 175 4 √
510414200 93 200 4 √

Finish Code: 1=Plain Brass, 3=Green TEFLON Coated, 4=White Polyester Coated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–150
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
TY-L
Pendent
K Factor K= 80 (5.6) • K= 115 (8.0)

Thread Size 1⁄2" NPT • 3⁄4" NPT

Approvals FM, CE

Temperature 74°C (165°F), 100°C (212°F), 138°C (280°F)

Escutcheon Style Style 20 • Style 65

Sprinkler Finish Stainless Steel

SIN K=80 (5.6) - TY3280, K=115 (8.0) - TY4280

Wrench Type W-TYPE 9, W-Type 10 (For recessed escutcheons)

Tech Data Sheet TFP683

TY-L: solder type, standard response, standard coverage • Stainless Steel, rated for corrosion resistance • All metal components
remove glass parts from facility • The properties of these sprinklers are intended to resist corrosion due to cleaning agents used in
wash-down procedures required in food production environments • Designed for use in light, ordinary and extra-hazard commercial
occupancies including food production facilities, factories, refineries and chemical plants.

TY-L, K=80 (5.6), 1 ⁄ 2" NPT


Pendent • K=80 [5.6] K=80 [5.6] • 1 ⁄ 2” NPT • TFP683
1
⁄ 2” NPT • SIN TY3280 Part No. Temperature Approvals & Listings

1/2" NPT Finish

FM
SIN TY3280 °C °F Code

CE
531120165 74 165 0  √
531120212 100 212 0  √
531120280 138 280 0  
66,7 mm √=Both Approved, =Recessed Pendent Not Approved
(2-5/8")

TY-L, K=115 (8.0), 3 ⁄4" NPT


K=115 [8.0] • 3 ⁄4” NPT • TFP683
Pendent • K=115 [8.0]
3
⁄4” NPT • SIN TY4280 Part No. Temperature Approvals & Listings
3/4" NPT Finish
FM

SIN TY4280 °C °F Code


CE

531020165 74 165 0  
531020212 100 212 0  
531020280 138 280 0  
(2-11/16") √=Both Approved, =Recessed Pendent Not Approved
68,3 mm

Finish Code: 0=Stainless Steel


Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–151
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


TY-B & TY-FRB (Alternate Materials Of Construction)
Upright & Pendent Sprinklers
K Factor K= 80 (5.6) • K= 115 (8.0)
1
Thread Size ⁄2" NPT • 3 ⁄4" NPT

Approvals UL, C-UL, LPCB, Lloyds, CE, MED,SAS

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F), 182°C (360°F)

Escutcheon Style Style 10 • Style 40

Sprinkler Finish Stainless Steel, SMO, Titanium

SIN Refer to Tech Data Sheet for SIN Numbers

Wrench Type W-TYPE 6, W-Type 7 (For recessed escutcheons)

Tech Data Sheet TFP680

TY-B: 5 mm diameter heat sensitive glass bulb, standard response • TY-FRB: 3 mm diameter heat sensitive glass bulb, quick
response • Corrosion resistant, standard coverage spray sprinklers designed for use in commercial occupancies where corrosive
atmospheres may exist • Alternate materials of construction (Stainless Steel, SMO, or Titanium) are utilised to extend the life of
a sprinkler beyond that which might be expected of copper alloy sprinklers exposed to corrosive atmospheres, (SMO = stainless-
molybdenum alloyed)

P/N 57 — XXX — 0 — XXX — SUFFIX

Standard Response (SR) Quick Response (QR) Temperature Rating Material


570 TY-B 5.6K Upright SR 370 TY-FRB 5.6K Upright QR 135 135°F (57°C) None Stainless Steel
590 TY-B 8.0K Upright SR 390 TY-FRB 8.0K Upright QR 155 155°F (68°C) M SMO**
571 TY-B 5.6K Pendent SR 371 TY-FRB 5.6K Pendent QR 175 175°F (79°C) T Titanium**
591 TY-B 8.0K Pendent SR 391 TY-FRB 8.0K Pendent QR 200 200°F (93°C) **5.6K only

573 TY-B 5.6K C/UP SR 373 TY-FRB 5.6K C/UP QR 286 286°F (141°C)
593 TY-B 8.0K C/UP SR 393 TY-FRB 8.0K C/UP QR 360 360°F (182°C)*
* TY-B only

TY-B, K=80 (5.6), 1 ⁄ 2" NPT TY-FRB, K=80 (5.6), 1 ⁄ 2" NPT

Upright • K=80 (5.6) Pendent • K=80 (5.6) Upright • K=80 (5.6) Pendent • K=80 (5.6)
1 1 1 1
⁄ 2" NPT ⁄ 2" NPT ⁄ 2" NPT ⁄ 2" NPT
TY-B: SIN TY8191 TY-B: SIN TY8291 TY-FRB: SIN TY8181 TY-FRB: SIN TY8281
TY-B SMO: SIN TY8192 TY-B SMO: SIN TY8292 TY-FRB SMO: SIN TY8182 TY-FRB SMO: SIN TY8282
TY-B Titanium: SIN TY8193 TY-B Titanium: SIN TY8293 TY-FRB Titanium: SIN TY8183 TY-FRB Titanium: SIN TY8283

57,2 mm 57,2 mm
57,2 mm 57,2 mm
(2-1/4") (2-1/4")
(2-1/4") (2-1/4")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–152
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
TY-B & TY-FRB (Alternate Materials Of Construction)

TY-B, K=115 (8.0), 3 ⁄4" NPT TY-FRB, K=115 (8.0), 3 ⁄4" NPT

Upright • K=115 (8.0) Pendent • K=115 (8.0) Upright • K=115 (8.0) Pendent • K=115 (8.0)
3 3 3 3
⁄4" NPT • SIN TY9191 ⁄4" NPT • SIN TY9291 ⁄4" NPT • SIN TY9181 ⁄4" NPT • SIN TY9281

57,2 mm 58,7 mm 57,2 mm 58,7 mm


(2-1/4") (2-5/16") (2-1/4") (2-5/16")

TY-B, K=80 (5.6), 1 ⁄ 2" NPT TY-FRB, K=80 (5.6), 1 ⁄ 2" NPT

Conventional • K=80 (5.6) Conventional • K=80 (5.6)


1 1
⁄ 2" NPT ⁄ 2" NPT
TY-B: SIN TY8691 TY-FRB: SIN TY8681
TY-B SMO: SIN TY8692 TY-FRB SMO: SIN TY8682
TY-B Titanium: SIN TY8693 TY-FRB Titanium: SIN TY8683

57,2 mm
(2-1/4") 57,2 mm
(2-1/4")

TY-B, K=115 (8.0), 3 ⁄4" NPT TY-FRB, K=115 (8.0), 3 ⁄4" NPT

Conventional • K=115 (8.0) Conventional • K=115 (8.0)


3 3
⁄4" NPT • SIN TY9691 ⁄4" NPT • SIN TY9681

57,2 mm
57,2 mm
(2-1/4")
(2-1/4")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–153
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


TY-B & TY-FRB (Alternate Materials Of Construction)
Vertical, Horizontal & Recessed Horizontal Sidewall Sprinklers
K Factor K= 80 (5.6)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, LPCB, Lloyds, CE, MED,SAS

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F), 182°C (360°F)

Escutcheon Style Style 10

Sprinkler Finish Stainless Steel, SMO, Titanium

SIN Refer to Tech Data Sheet for SIN Numbers

Wrench Type W-TYPE 6, W-Type 7 (For recessed escutcheons)

Tech Data Sheet TFP680

TY-B: 5 mm diameter heat sensitive glass bulb, standard response • TY-FRB: 3 mm diameter heat sensitive glass bulb, quick
response • Corrosion resistant, standard coverage spray sprinklers designed for use in commercial occupancies where corrosive
atmospheres may exist • Alternate materials of construction (Stainless Steel, SMO, or Titanium) are utilised to extend the life of
a sprinkler beyond that which might be expected of copper alloy sprinklers exposed to corrosive atmospheres (SMO = stainless-
molybdenum alloyed)

P/N 57 — XXX — 0 — XXX — SUFFIX

Standard Response (SR) Quick Response (QR) Temperature Rating Material


578 TY-B 5.6K HSW SR 378 TY-FRB 5.6K HSW QR 135 135°F (57°C) None Stainless Steel
575 TY-B 5.6K VSW SR 375 TY-FRB 5.6K VSW QR 155 155°F (68°C) M SMO**
175 175°F (79°C) T Titanium**
200 200°F (93°C) **5.6K only

286 286°F (141°C)


360 360°F (182°C)*
* TY-B only

TY-B, K=80 (5.6), 1 ⁄ 2" NPT TY-FRB, K=80 (5.6), 1 ⁄ 2" NPT

Horizontal Sidewall • K=80 (5.6) Vertical Sidewall • K=80 (5.6) Horizontal Sidewall • K=80 (5.6) Vertical Sidewall • K=80 (5.6)
1 1 1 1
⁄ 2" NPT ⁄ 2" NPT ⁄ 2" NPT ⁄ 2" NPT
TY-B: SIN TY8391 TY-B: SIN TY8491 TY-FRB: SIN TY8381 TY-FRB: SIN TY8481
TY-B SMO: SIN TY8392 TY-B SMO: SIN TY8492 TY-FRB SMO: SIN TY8382 TY-FRB SMO: SIN TY8482
TY-B Titanium: SIN TY8393 TY-B Titanium: SIN TY8493 TY-FRB Titanium: SIN TY8383 TY-FRB Titanium: SIN TY8483

57,2 mm 57,2 mm
(2-1/4") (2-1/4")

57,2 mm 57,2 mm
(2-1/4") (2-1/4")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–154
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
TY-B & TY-FRB (Poly-Stainless)
Upright, Pendent & Horizontal Sidewall Sprinklers
K Factor K= 80 (5.6) • K= 115 (8.0)
1
Thread Size ⁄2" NPT • 3 ⁄4" NPT

Refer to Pages listed below under Tech Data Sheets


Approvals
for approval listings

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F), 182°C (360°F)

Escutcheon Style Style 10 • Style 40

Sprinkler Finish Poly-Stainless

SIN Refer to Tech Data Sheet for SIN Numbers

Wrench Type W-TYPE 6, W-Type 7 (For recessed escutcheons)

TFP151 (page 1-6), TFP161 (page 1-8),


Tech Data Sheet
TFP171 (page 1-12, 1-14), TFP176 (page 1-16)

TY-B: 5 mm diameter heat sensitive glass bulb, standard response • TY-FRB: 3 mm diameter heat sensitive glass bulb, quick
response • Corrosion resistant, standard coverage spray sprinklers designed for use in commercial occupancies where corrosive
atmospheres may exist • Corrosive environments can wreak havoc on standard sprinkler heads. The TYCO Poly-Stainless sprinklers
are here to maintain the aesthetics of a sprinkler in a wide range of corrosive locations.

TY-B

TY-B, K=80 (5.6), 1 ⁄ 2" NPT TY-B, K=115 (8.0), 3 ⁄4" NPT

Upright • K=80 [5.6] Pendent • K=80 [5.6] Upright • K=115 [8.0] Pendent • K=115 [8.0]
3
1
⁄ 2” NPT • SIN TY3151
1
⁄ 2” NPT • SIN TY3251 ⁄4” NPT • SIN TY4151 3
⁄4” NPT • SIN TY4251

55,6 mm 55,6 mm 57,2 mm 58,7 mm


(2-3/16") (2-3/16") (2-5/16")
(2-1/4")

TY-B, K=80 (5.6), 1 ⁄ 2" NPT

Horizontal Sidewall • K=80 [5.6]


1
⁄ 2” NPT • SIN TY3351

55,6 mm
(2-3/16")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–155
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Special Application Sprinklers


TY-B & TY-FRB (Poly-Stainless)

TY-FRB, K=80 (5.6), 1 ⁄ 2" NPT TY-FRB, K=80 (5.6), 1 ⁄ 2" NPT

Horizontal Sidewall • K=80 [5.6]


1
Upright • K=80 [5.6] Pendent • K=80 [5.6] ⁄ 2” NPT • SIN TY3331
1 1
⁄ 2” NPT • SIN TY3131 ⁄ 2” NPT • SIN TY3231

55,6 mm 55,6 mm
(2-3/16") (2-3/16") 55,6 mm
(2-3/16")

TY-FRB, K=115 (8.0), 3 ⁄4" NPT

Upright • K=115 [8.0] Pendent • K=115 [8.0]


3 3
⁄4” NPT • SIN TY4131 ⁄4” NPT • SIN TY4231

54,0 mm
57,2 mm
(2-1/4") (2-1/8")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–156
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Multiple Jet Controls
MJCS
Multi Jet Controls, Single Inlet, Single Outlet
3
Thread Size ⁄4" BSP x 3 ⁄4" BSPT

Approvals LPCB

68°C (155°F), 79°C (175°F), 93°C (200°F), 141°C (286°F),


Temperature
182°C (360°F), 227°C (440°F), 260°C (500°F)

Sprinkler Finish Natural Brass

SIN Refer to Tech Data Sheet for SIN Numbers

Tech Data Sheet Contact Tyco Fire Products for more Information

109mm
MJCS
Approvals &
Temperature
Listings

Outlet Part No.

LPCB
°C °F

MJCSO0027B 68 155 √
113mm MJCSO0027D 79 175 √
MJCSO0027E 93 200 √
MJCSO0027G 141 286 √
MJCSO0027H 182 360 √
MJCSO0027I 227 440 √
MJCSO0027J 260 500 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–157
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Multiple Jet Controls


MJCD
Multi Jet Controls, Single Inlet, Double Outlet
Inlet Size DN20 - DN40 Male, or DN50 Female

Outlet Size 20 - 40mm (3 ⁄4" - 1-1 ⁄ 2") BSP

Approvals LPCB

68°C (155°F), 79°C (175°F), 93°C (200°F), 141°C (286°F),


Temperature
182°C (360°F), 227°C (440°F), 260°C (500°F)

Finish Natural Brass

SIN Refer to Tech Data Sheet for SIN Numbers

Tech Data Sheet Contact Tyco Fire Products for more Information

C
A
B

H
D E F
Outlet BSP Outlet BSP

G
Approvals &
Temperature Dimensions (mm)
Listings
Part No. G H

LPCB
°C °F A B C D E F
mm In. mm In
3 3
MJCDO0027B 68 [155] 165 - - 110 50 20 20 ⁄4 ” 20 ⁄4 ” √
3 3
MJCDO0027D 79 [175] 165 - - 110 50 20 20 ⁄4 ” 20 ⁄4 ” √
3 3
MJCDO0027E 93 [200] 165 - - 110 50 20 20 ⁄4 ” 20 ⁄4 ” √
3 3
MJCDO0027G 141 [286] 165 - - 110 50 20 20 ⁄4 ” 20 ⁄4 ” √
3 3
MJCDO0027H 182 [360] 165 - - 110 50 20 20 ⁄4 ” 20 ⁄4 ” √
3 3
MJCDO0027I 227 [440] 165 - - 110 50 20 20 ⁄4 ” 20 ⁄4 ” √
3 3
MJCDO0027J 260 [500] 165 - - 110 50 20 20 ⁄4 ” 20 ⁄4 ” √
MJCDO0034B 68 [155] 196 67 105 148 60 23 25 1” 25 1” √
MJCDO0034D 79 [175] 196 67 105 148 60 23 25 1” 25 1” √
MJCDO0034E 93 [200] 196 67 105 148 60 23 25 1” 25 1” √
MJCDO0034G 141 [286] 196 67 105 148 60 23 25 1” 25 1” √
MJCDO0034H 182 [360] 196 67 105 148 60 23 25 1” 25 1” √
MJCDO0034I 227 [440] 196 67 105 148 60 23 25 1” 25 1” √
MJCDO0034J 260 [500] 196 67 105 148 60 23 25 1” 25 1” √
MJCDO0048B 68 [155] 230 67 107 165 70 25 40 1-1 ⁄ 2” 25 1” √
MJCDO0048D 79 [175] 230 67 107 165 70 25 40 1-1 ⁄ 2” 25 1” √
MJCDO0048E 93 [200] 230 67 107 165 70 25 40 1-1 ⁄ 2” 25 1” √
MJCDO0048G 141 [286] 230 67 107 165 70 25 40 1-1 ⁄ 2” 25 1” √
MJCDO0048H 182 [360] 230 67 107 165 70 25 40 1-1 ⁄ 2” 25 1” √
MJCDO0048I 227 [440] 230 67 107 165 70 25 40 1-1 ⁄ 2” 25 1” √
MJCDO0048J 260 [500] 230 67 107 165 70 25 40 1-1 ⁄ 2” 25 1” √
MJCDO0060B 68 [155] 225 69 136 182 60 25 50 2” 40 1-1 ⁄ 2” √
MJCDO0060D 79 [175] 225 69 136 182 60 25 50 2” 40 1-1 ⁄ 2” √
MJCDO0060E 93 [200] 225 69 136 182 60 25 50 2” 40 1-1 ⁄ 2” √
MJCDO0060G 141 [286] 225 69 136 182 60 25 50 2” 40 1-1 ⁄ 2” √
MJCDO0060H 182 [360] 225 69 136 182 60 25 50 2” 40 1-1 ⁄ 2” √
MJCDO0060I 227 [440] 225 69 136 182 60 25 50 2” 40 1-1 ⁄ 2” √
MJCDO0060J 260 [500] 225 69 136 182 60 25 50 2” 40 1-1 ⁄ 2” √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–158
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Special Application Sprinklers
MJC
Multi Jet Controls, Double Inlet, Single Outlet
3
Thread Size ⁄4" BSP x 3 ⁄4" BSPT

Approvals VdS

Temperature 68°C (155°F)

Bulb 5mm

Response Standard Response

Sprinkler Finish Natural Brass

SIN Refer to Tech Data Sheet for SIN Numbers

Tech Data Sheet Contact Tyco Fire Products for more Information

A
B
Temperature Dimensions (mm) Approvals & Listings
Part No. Equivalent
VdS

°C °F B C D
Length
2122206 68°C 155°F 2.2 m 105 58 110 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–159
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Sprinkler Accessories
For use with the sprinklers and nozzles described in this Catalogue.

- Improve Appearance - Protection From Damage

- Conceal Clearance Holes - Onsite Emergency


Storage Supply

1–160
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Sprinkler Accessories
Escutcheon Plates
1
⁄ 2" NPT Recessed Escutcheons
1
Thread Size ⁄2" NPT - Styles 10, 15, 20, & 50

Recessed Escutcheons are detailed in individual


Approvals
pendent and horizontal sidewall sprinkler data sheets

Escutcheon Styles Styles 10, 15, 20, & 50

Pure White, Signal White, Jet Black, Chrome Plated,


Finishes
Brass Plated, Plain, Grey Aluminium

Tech Data Sheet TFP770

Consists of a mounting plate and closure for finished appearance in ceilings or soffits • Intended for use in areas with finished
ceilings or walls, and the adjustment provided by these escutcheons reduces the accuracy to which fixed piping to the sprinklers
must be cut, while providing a decorative recessed sprinkler installation • Primarily designed for use with standard spray, quick
response sprinklers and the Designer residential sidewall sprinklers • Maximum 12,7 to 19,1mm (1 ⁄ 2" to 3 ⁄4") adjustment

1/2" NPT 49,2 mm 49,2 mm


MOUNTING 1/2" NPT (1-15/16") DIA.
(1-15/16") DIA. 28,6 mm MOUNTING
PLATE CLOSURE (1-1/8") 25,4 mm
PLATE CLOSURE (1")

FLUSH TO 73,0 mm 3,2 mm FLUSH TO 73,0 mm 3,2 mm


(3/4") 19,1 mm (2-7/8") DIA. (1/8") (5/8") 15,9 mm (2-7/8") DIA. (1/8")
STYLE 10 RECESSED ESCUTCHEON, STYLE 15 RECESSED ESCUTCHEON
1/2 IN. NPT - 3/4 IN. ADJUSTMENT 1/2 IN. NPT - 5/8 IN. ADJUSTMENT
Style 10 - Part No. Style 15 - Part No.
Finish Finish
Steel Stainless Steel Steel Stainless Steel
- 567011010 Plain Unpolished 567152010 - Brass Plated
567012010 - Brass Plated 567153010 - Pure White (RAL9010)
567013010 - Pure White (RAL9010) 567154010 567150010 Signal White (RAL9003)
567014010 567010010 Signal White (RAL9003) 567156010 - Jet Black (RAL9005)
567016010 - Jet Black (RAL9005) 567159010 - Chrome Plated
- 567017010 Grey Aluminium (RAL9007)
567019010 - Chrome Plated

1/2" NPT 49,2 mm 1/2" NPT 46,0 mm


MOUNTING (1-15/16") DIA. MOUNTING (1-13/16") DIA.
PLATE 20,6 mm 20,6 mm
CLOSURE PLATE
(13/16") CLOSURE (13/16")

FLUSH TO 73,0 mm 3,2 mm FLUSH TO 73,0 mm 2,4 mm


12,7 mm (1/2") (2-7/8") DIA. (1/8") (3/8") 9,5 mm (2-7/8") DIA. (3/32")

STYLE 20 RECESSED ESCUTCHEON STYLE 50 RECESSED ESCUTCHEON


1/2 IN. NPT - 1/2 IN. ADJUSTMENT 1/2 IN. NPT - 3/8 IN. ADJUSTMENT
Style 20 - Part No. Style 50 - Part No.
Finish Finish
Steel Stainless Steel Steel Stainless Steel
- 567051010 Plain Unpolished - 567111010 Plain Unpolished
567052010 - Brass Plated 567112010 - Brass Plated
567053010 - Pure White (RAL9010) 567113010 - Pure White (RAL9010)
567054010 567050010 Signal White (RAL9003) 567114010 567110010 Signal White (RAL9003)
567056010 - Jet Black (RAL9005) 567119010 - Chrome Plated
567059010 - Chrome Plated
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–161
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Sprinkler Accessories
Escutcheon Plates
3
⁄8" or 3 ⁄4" NPT Recessed Escutcheons
3
⁄ 8" NPT - Styles 70
Thread Size 3
⁄4" NPT - Styles 30, & 40

Recessed Escutcheons are detailed in individual


Approvals
pendent and horizontal sidewall sprinkler data sheets

Escutcheon Styles Styles 30, 40, & 70

Pure White, Signal White, Jet Black, Chrome Plated,


Finishes
Brass Plated, Plain

Tech Data Sheet TFP770

Consists of a mounting plate and closure for finished appearance in ceilings or soffits • Intended for use in areas with finished
ceilings or walls, and the adjustment provided by these escutcheons reduces the accuracy to which fixed piping to the sprinklers
must be cut, while providing a decorative recessed sprinkler installation • Primarily designed for use with standard spray, quick
response sprinklers and the Designer residential sidewall sprinklers • Maximum 12,7 to 19,1mm (1 ⁄ 2" to 3 ⁄4") adjustment

3/4" NPT 49,2 mm 3/4" NPT 49,2 mm


MOUNTING (1-15/16") DIA. MOUNTING (1-15/16") DIA.
28,6 mm
PLATE 20,6 mm PLATE CLOSURE (1-1/8")
CLOSURE
(13/16")

FLUSH TO 73,0 mm 3,2 mm FLUSH TO 73,0 mm 3,2 mm


12,7 mm (1/2") (2-7/8") DIA. (1/8") 19,1 mm (3/4") (2-7/8") DIA. (1/8")

STYLE 30 RECESSED ESCUTCHEON STYLE 40 RECESSED ESCUTCHEON


3/4 IN. NPT - 1/2 IN. ADJUSTMENT 3/4 IN. NPT - 3/4 IN. ADJUSTMENT

Style 30 - Part No. Style 40 - Part No.


Finish Finish
Steel Stainless Steel Steel Stainless Steel
- 567051011 Plain Unpolished - 567001010 Plain Unpolished
567052011 - Brass Plated 567002010 - Brass Plated
567053011 - Pure White (RAL9010)* 567003010 - Pure White (RAL9010)*
567054011 567050011 Signal White (RAL9003) 567004010 567000010 Signal White (RAL9003)
567056011 - Jet Black (RAL9005) 567006010 - Jet Black (RAL9005)
567059011 - Chrome Plated - 567007010 Grey Aluminium (RAL9007)
567009010 - Chrome Plated

3/8" NPT 49,2 mm Style 70 - Part No.


(1-15/16") DIA. Finish
MOUNTING 28,6 mm Steel Stainless Steel
PLATE CLOSURE (1-1/8") - ESCSTDSS10 Plain Unpolished
ESCSTDBR10 - Brass
ESCSTDRA10 - Pure White (RAL9010)*
ESCSTDWH10 Signal White (RAL9003)
ESCSTDJB10 - Jet Black (RAL9005)
- Grey Aluminium (RAL9007)
FLUSH TO 3,2 mm ESCSTDCH10 - Chrome Plated
73,0 mm
19,1 mm (3/4") (2-7/8") DIA. (1/8")

STYLE 70 RECESSED ESCUTCHEON


3/8 IN. NPT - 3/4 IN. ADJUSTMENT

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–162
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Sprinkler Accessories
Escutcheon Plates
Style 65, One-Piece Flat Escutcheon
Style 401, Two-Piece Adjustable Escutcheon
1
Thread Size ⁄2" NPT • 3 ⁄4" NPT

Recessed Escutcheons are detailed in individual


Approvals
pendent and horizontal sidewall sprinkler data sheets

Style 65 Escutcheon Styles Styles 65, 401


Style 401
Finishes Chrome, Signal White, or Brass

Tech Data Sheet TFP777

Used to improve the overall appearance of the sprinkler installation by concealing the clearance holes required for wall or ceiling
installation • Deep, two-piece, adjustable • Available for 1 ⁄ 2" and 3 ⁄4" NPT

71,4 mm Style 65 - Part No.


(2-13/16") 1 3 Finish
⁄ 2" NPT ⁄4" NPT
1150 1184 Brass Plated
1174 1175 Signal White (RAL9003)
1153 1152 Chrome Plated

12,7 mm
(1/2")

89,0 mm Style 401 - Part No.


(3-1/2") Cup Finish
Skirt
57,2 mm 1
⁄ 2" NPT 3
⁄4" NPT
(2-1/4")
1194 1195 1199 Brass Plated
1196 1197 1200 Signal White (RAL9003)
1192 1193 1198 Chrome Plated

73,0 mm MAX.
(2-7/8")

47,6 mm MIN.
(1-7/8")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–163
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Sprinkler Accessories
Escutcheon Plates

Style 60, Two-Piece Flush Escutcheon


3
Thread Size ⁄4" NPT

UL- Listed for use with Series EC-11 and EC-14


Approvals Pendent Sprinklers
FM

Escutcheon Styles Styles 60

Finishes Chrome, Signal White, or Brass

Tech Data Sheet TFP778

Used to improve the overall appearance of the sprinkler installation by concealing the clearance holes required for wall or ceiling
installation • Deep, two-piece, adjustable • 19,1mm (3 ⁄4") total adjustment

73,0 mm Style 60 - Part No.


(2-7/8") DIA. 3 Finish
⁄4" NPT
57,2 mm 208107 Brass Plated
(2-1/4") DIA. 208104 Signal White (RAL9003)
208102 Chrome Plated

3,2 mm
(1/8")

Face Of
Sprinkler Fitting:
9,5 mm (3/8") Above
to 3,2 mm (1/8") Below
Mounting Surface 3/4" NPT
Mounting
Escutcheon Plate
Plate
Seating Surface:
6,4 mm (1/4") Above 58,7 mm (2-5/16")
to 12,7 mm (1/2") Below
Mounting Surface; 46,0 mm (1-13/16")
19,1 mm (3/4") Total
Adjustment

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–164
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Sprinkler Accessories
Sprinkler Head Cabinet
3, 6 or 12 Capacity

1
Thread Size ⁄2" NPT • 3 ⁄4" NPT • 1" NPT

Tech Data Sheet TFP785

Provides storage for spare sprinklers and sprinkler wrench • Spare sprinklers facilitate the prompt replacement of operated or
damaged sprinklers and return of fire protection system to service as soon as possible

3 Sprinklers Part #
No. Sprinkler Heads
1177 3
1119 6
Remove Knockouts 1124 12
To Accommodate Holes Accommodate 1111 6 - ESFR
3/4" NPT Sprinklers 1/2" NPT Sprinklers

184,2 mm 65,1 mm
(7-1/4") (2-9/16")

127,0 mm
(5")

6 Sprinklers

Remove Knockouts
Holes Accommodate
To Accommodate
1/2" NPT Sprinklers
3/4" NPT Sprinklers

357,2 mm 65,1 mm
(14-1/16") (2-9/16")

127,0 mm
(5")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–165
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Sprinkler Accessories
Sprinkler Head Cabinet

6-ESFR Sprinklers

Remove Knockouts
Holes Accommodate
To Accommodate
3/4" NPT Sprinklers
1" NPT Sprinklers

357,2 mm 79,4 mm
(14-1/16") (3-1/8")

157,2 mm
(6-3/16")

12 Sprinklers

Remove Knockouts
Holes Accommodate
To Accommodate
1/2" NPT Sprinklers
3/4" NPT Sprinklers

357,2 mm 104,8 mm
(14-1/16") (4-1/8")

127,0 mm
(5")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–166
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Sprinkler Accessories
Sprinkler Head Cabinet

B I
I
D E
A

B II
B
III

A A

Sprinkler Dimensions (mm)


Part No. Model Finish
Capacity Connection A B C D E
1
240036 36 ⁄ 2”, 3 ⁄4” I 103 306 358 90 - Red
SP50001 50 * III 320 150 470 50 - Red
1
240012 12 ⁄ 2”, 3 ⁄4” I 103 132 363 45 - Red
1
240006 6 ⁄ 2”, 3 ⁄4” I 64 130 355 42 126 Red
3
240306 6 ⁄4”, 1”** I 80 160 357 46 - Red
1
240024 24 ⁄ 2”, 3 ⁄4” I 103 275 300 90 - Red
* Non perforated shelf

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–167
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Nozzle & Nozzle Accessories
Designed for use in a variety of special hazard application – may be required to provide a
properly designed special hazard fire protection system.
- Flammable Liquid Ranks - Industrial Process Equipment
& Operations
- Computer Rooms
- Flammable Liquid Storage
- Clean Rooms
- Offshore Platforms

1–168
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Nozzles and Accessories
MV
Medium Velocity Nozzle
1
Thread Size ⁄2" NPT
UL, FM*, SAS, Ukrainian, Fire Academy of Russia,
Approvals PAVUS, T/S/U
* Titanium is not FM approved

Spray Angles 90°, 95°, 110°, 125°, 140°, and 160°

Stainless Steel, Brass & Leaded Gunmetal LG2,


Nozzle Finish
Titanium, or 254 SMO

Wrench Type Appropriate size adjustable Crescent wrench

Tech Data Sheet TFP807

Nozzles with an orifice smaller than 9.5 mm include a filter. • Nozzles can be coated or made in special material on request. • Spray
patterns are available on request.

1/2" NPT

17,5 mm
(11/16")

65,1 mm
(2-9/16")

55,6 mm
(2-3/16")

47,6 mm
(1-7/8")

MV • 1 ⁄ 2" NPT
K-Factors MV10 MV12 MV15 MV18 MV19 MV21 MV25 MV26 MV30 MV34 MV47 MV57
Ø mm 5.1 5.4 6.3 6.8 7.1 7.7 8.3 8.8 9 9.6 11.2 12.6
Ø inch 0.2 0.21 0.25 0.27 0.28 0.31 0.33 0.35 0.36 0.38 0.44 0.5
K Metric 15.9 18 23.8 28 30.2 34 38.2 42 50 58.8 80 99.5
K USA 1.1 1.25 1.65 1.94 2.09 2.36 2.65 2.91 3.47 4.07 5.54 6.9

MV • 1 ⁄ 2” NPT
Brass and Leaded Gunmetal LG2 Part No. Approvals & Listings
Ukrainian

Academy
of Russia

Model
PAVUS

T/S/U
SAS

Fire
FM

No. 90° 95° 110° 125° 140° 160°


UL

MV10 AED03829 AEA02524 AEA02533 AEA02542 AEA02551 AEA02560 √ √ √ √ √ √ √


MV12 AED03838 AED03847 AED03856 AED03865 AED03874 AED03883 √ √ √ √ √ √ √
MV15 AED03892 AEA02588 AEA02597 AEA02609 AEA02618 AEA02627 √ √ √ √ √ √ √
MV18 AED03904 AED03913 AED03922 AED03931 AED03940 AED03959 √ √ √ √ √ √ √
MV19 AED03968 AEA02645 AEA02654 AEA02663 AEA02672 AEA02681 √ √ √ √ √ √ √
MV21 AED03977 AED03986 AED03995 AED04004 AED04013 AED04022 √ √ √ √ √ √ √
MV25 AED04031 AEA02702 AEA02711 AEA02720 AEA02739 AEA02748 √ √ √ √ √ √ √
MV26 AED04040 AED04059 AED04068 AED04077 AED04086 AED04095 √ √ √ √ √ √ √
MV30 AED04107 AED04116 AED04125 AED04134 AED04143 AED04152 √ √ √ √ √ √ √
MV34 AED04161 AED00949 AED00958 AED00967 AED00976 AED00985 √ √ √ √ √ √ √
MV47 AED04170 AED01003 AED01012 AED01021 AED01030 AED01049 √ √ √ √ √ √ √
MV57 AED04189 AED01067 AED01076 AED01085 AED01094 AED01106 √ √ √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–169
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Nozzles and Accessories


MV - Medium Velocity Nozzle

MV • 1 ⁄ 2” NPT
Stainless Steel Type 316 Part No. Approvals & Listings

Ukrainian

Academy
of Russia
Model

PAVUS

T/S/U
SAS

Fire
FM
No. 90° 95° 110° 125° 140° 160°

UL
MV10 AED07063 AED00024 AED00033 AED00042 AED00051 AED02560 √ √ √ √ √ √ √
MV12 AED07612 AED07621 AED07630 AED07649 AED07658 AED07667 √ √ √ √ √ √ √
MV15 AED07676 AED00088 AED00097 AED00109 AED00118 AED00127 √ √ √ √ √ √ √
MV18 AED07685 AED07694 AED07706 AED07715 AED07724 AED07733 √ √ √ √ √ √ √
MV19 AED07742 AED00145 AED00154 AED00163 AED00172 AED00181 √ √ √ √ √ √ √
MV21 AED07760 AED07779 AED07788 AED07797 AED07809 AED07818 √ √ √ √ √ √ √
MV25 AED07751 AED00202 AEA00211 AED00220 AEA00239 AEA00248 √ √ √ √ √ √ √
MV26 AED07827 AED07836 AED07845 AED07854 AED07863 AED07872 √ √ √ √ √ √ √
MV30 AED07881 AED07890 AED07902 AED07911 AED07920 AED07939 √ √ √ √ √ √ √
MV34 AED07948 AED01218 AED01227 AED01236 AED01245 AED01254 √ √ √ √ √ √ √
MV47 AED07957 AED01272 AED01281 AED01290 AED01302 AED01311 √ √ √ √ √ √ √
MV57 AED07966 AED01339 AED01348 AED01357 AED01366 AED01375 √ √ √ √ √ √ √

MV • 1 ⁄ 2” NPT
Titanium Part No. Approvals & Listings

Ukrainian

Academy
of Russia
Model

PAVUS

T/S/U
SAS

Fire
No. 90° 95° 110° 125° 140° 160°
UL

MV10 AED07603T AEA00024T AED00033T AEA00042T AEA00051T AEA02560T √ √ √ √ √ √


MV12 AED07612T AED07621T AED07630T AED07649T AED07658T AED07667T √ √ √ √ √ √
MV15 AED07676T AEA00088T AED00097T AED00109T AEA00118T AEA00127T √ √ √ √ √ √
MV18 AED07685T AED07694T AED07706T AED07715T AED07724T AED07733T √ √ √ √ √ √
MV19 AED07742T AEA00145T AED00154T AED00163T AEA00172T AED00181T √ √ √ √ √ √
MV21 AED07760T AED07779T AED07788T AED07797T AED07809T AED07818T √ √ √ √ √ √
MV25 AED07751T AEA00202T AEA00211T AED00220T AEA00239T AEA00248T √ √ √ √ √ √
MV26 AED07827T AED07836T AED07845T AED07854T AED07863T AED07872T √ √ √ √ √ √
MV30 AED07881T AED07890T AED07902T AED07911T AED07920T AED07939T √ √ √ √ √ √
MV34 AED07948T AED01218T AED01227T AED01236T AED01245T AED01254T √ √ √ √ √ √
MV47 AED07957T AED01272T AED01281T AED01290T AED01302T AED01311T √ √ √ √ √ √
MV57 AED07966T AED01339T AED01348T AED01357T AED01366T AED01375T √ √ √ √ √ √

MV • 1 ⁄ 2” NPT
254 SMO Part No. Approvals & Listings
Ukrainian

Academy
of Russia

Model
PAVUS
T/S/U
SAS

Fire
FM

No. 90° 95° 110° 125° 140° 160°


UL

MV10 AED07603SMO AED00024SMO AED00033SMO AED00042SMO AED00051SMO AED02560SMO √ √ √ √ √ √ √


MV12 AED07612SMO AED07621SMO AED07630SMO AED07649SMO AED07658SMO AED07667SMO √ √ √ √ √ √ √
MV15 AED07676SMO AED00088SMO AED00097SMO AED00109SMO AED00118SMO AED00127SMO √ √ √ √ √ √ √
MV18 AED07685SMO AED07694SMO AED07706SMO AED07715SMO AED07724SMO AED07733SMO √ √ √ √ √ √ √
MV19 AED07742SMO AED00145SMO AED00154SMO AED00163SMO AED00172SMO AED00181SMO √ √ √ √ √ √ √
MV21 AED07760SMO AED07779SMO AED07788SMO AED07797SMO AED07809SMO AED07818SMO √ √ √ √ √ √ √
MV25 AED07751SMO AEA00202SMO AEA00211SMO AED00220SMO AEA00239SMO AEA00248SMO √ √ √ √ √ √ √
MV26 AED07827SMO AED07836SMO AED07845SMO AED07854SMO AED07863SMO AED07872SMO √ √ √ √ √ √ √
MV30 AED07881SMO AED07890SMO AED07902SMO AED07911SMO AED07920SMO AED07939SMO √ √ √ √ √ √ √
MV34 AED07948SMO AED01218SMO AED01227SMO AED01236SMO AED01245SMO AED01254SMO √ √ √ √ √ √ √
MV47 AED07957SMO AED01272SMO AED01281SMO AED01290SMO AED01302SMO AED01311SMO √ √ √ √ √ √ √
MV57 AED07966SMO AED01339SMO AED01348SMO AED01357SMO AED01366SMO AED01375SMO √ √ √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–170
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Nozzles and Accessories
Sealed MV
Medium Velocity Nozzle
K Factor K= 57 (4.0), K= 80 (5.6)
1
Thread Size ⁄2" NPT

Spray Angles 90°, 95°, 110°, 125°, 140°, and 160°

57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F),


Temperature
141°C (286°F), 182°C (360°F)

Nozzle Finish Bronze: Natural Finish

Wrench Type W-TYPE 6

Tech Data Sheet Contact Tyco Fire Products for more Information

Nozzles can be coated or made in special material on request. • Spray patterns are available on request.

53mm

29mm

MV47 • K=80 (5.6) • 1 ⁄ 2” NPT


Bronze Part No.
Temperature
°C 90° 95° 110° 125° 140° 160°

57 29396 28402 28408 28414 28420 28426


68 28397 28403 28409 28415 28421 28427
79 28398 28404 28410 28416 28422 28428
93 28399 28405 28411 28417 28423 28429
141 28400 28406 28412 28418 28424 28430
182 28401 28407 28413 28419 28425 28431
Min. 1.4 Bar [20 Psi]

MV434 • K=57 (4.0) • 1 ⁄ 2” NPT


Bronze Part No.
Temperature
°C 90° 95° 110° 125° 140° 160°

57 28432 28438 28444 28450 28450 28462


68 28433 28439 28445 28451 28451 28463
79 28434 28440 28446 28452 28452 28464
93 28435 28441 28447 28453 28453 28465
141 28436 28442 28448 28454 28454 28466
182 28437 28443 28449 28455 28455 28467
Min. 1.4 Bar [20 Psi]

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–171
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Nozzles and Accessories


MV-T
Tank Top Medium Velocity Nozzle

1
Thread Size ⁄2" NPT

Approvals UL

Stainless Steel, Brass & Leaded Gunmetal LG2,


Materials
Titanium, Aluminium Bronze, SMO254, or Zeron 100

Tech Data Sheet TFP809

Nozzles with an orifice size of 9.5 mm and under are fitted with a strainer.

47,6 mm
(1-7/8")

55,6 mm
(2-3/16")

65,1 mm
(2-9/16")

17,5 mm*
(11/16")

1/2" NPT

MV-T • 1⁄ 2” NPT
Approvals &
Part No.
Minimum Listings
Orifice Diameter K-factor Brass &
Size mm LPM/bar½ Stainless Leaded Aluminium Zeron
Titanium SMO 254
UL

(Inches) Steel Gunmetal Bronze 100


LG2
MV10T 5,15 (0.20) 17,3 28492 28285 28492T 28285AB 28492SMO 28492Z √
MV12T 5,40 (0.21) 18,7 28493 28281 28493T 28281AB 28493SMO 28493Z √
MV15T 6,35 (0.25) 25,9 28494 28282 28494T 28282AB 28494SMO 28494Z √
MV18T 6,80 (0.27) 28,8 28495 28283 28495T 28283AB 28495SMO 28495Z √
MV19T 7,15 (0.28) 31,7 28496 28286 28496T 28286AB 28496SMO 28496Z √
MV21T 7,70 (0.30) 36,0 28497 28287 28497T 28287AB 28497SMO 28497Z √
MV25T 8,35 (0.33) 41,8 28498 28288 28498T 28288AB 28498SMO 28498Z √
MV26T 8,80 (0.34) 44,6 28499 28289 28499T 28289AB 28499SMO 28499Z √
MV30T 9,00 (0.35) 49,0 28500 28290 28500T 28290AB 28500SMO 28500Z √
MV34T 9,60 (0.38) 59,0 28501 28291 28501T 28291AB 28501SMO 28501Z √
MV47T 11,20 (0.44) 79,2 28502 28292 28502T 28292AB 28502SMO 28502Z √
MV57T 12,60 (0.50) 100,8 28503 28293 28503T 28293AB 28503SMO 28503Z √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–172
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Nozzles and Accessories
MV-R
Reverse Acting Medium Velocity Nozzle
1
Thread Size ⁄2" NPT

Approvals UL, FM

Stainless Steel, Brass & Leaded Gunmetal LG2,


Nozzle Finish
Titanium, Aluminium Bronze, SMO254, or Zeron 100

Tech Data Sheet TFP809

Nozzles can be coated or made in special material on request. • Spray patterns are available on request.

47,6 mm
(1-7/8")

55,6 mm
(2-3/16")

65,1 mm
(2-9/16")

17,5 mm*
(11/16")

1/2" NPT

MV-R • 1⁄ 2” NPT
Part No. Approvals & Listings
Minimum
Brass &
Orifice Diameter K-factor
Stainless Leaded Aluminium Zeron FM
Size mm LPM/bar½ Titanium SMO 254
UL

Steel Gunmetal Bronze 100


(Inches)
LG2
MV10R 5,15 (0.20) 17,3 28480 28383 28480T 28383AB 28480SMO 28480Z √ √
MV12R 5,40 (0.21) 18,7 28481 28384 28481T 28384AB 28481SMO 28481Z √ √
MV15R 6,35 (0.25) 25,9 28482 28385 28482T 28385AB 28482SMO 28482Z √ √
MV18R 6,80 (0.27) 28,8 28483 28386 28483T 28386AB 28483SMO 28483Z √ √
MV19R 7,15 (0.28) 31,7 28484 28387 28484T 28387AB 28484SMO 28484Z √ √
MV21R 7,70 (0.30) 36,0 28485 28388 28485T 28388AB 28485SMO 28485Z √ √
MV25R 8,35 (0.33) 41,8 28486 28389 28486T 28389AB 28486SMO 28486Z √ √
MV26R 8,80 (0.34) 44,6 28487 28390 28487T 28390AB 28487SMO 28487Z √ √
MV30R 9,00 (0.35) 49,0 28488 28391 28488T 28391AB 28488SMO 28488Z √ √
MV34R 9,60 (0.38) 59,0 28489 28392 28489T 28392AB 28489SMO 28489Z √ √
MV47R 11,20 (0.44) 79,2 28490 28393 28490T 28393AB 28490SMO 28490Z √ √
MV57R 12,60 (0.50) 100,8 28491 28394 28491T 28394AB 28491SMO 28491Z √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–173
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Nozzles and Accessories


Type A
Drencher Nozzle

K Factor K= 25, K= 43

1
Thread Size ⁄2" NPT

Spray Angles 125°

Nozzle Finish Bronze: Natural Finish

Tech Data Sheet Contact Tyco Fire Products for more Information

Nozzles can be coated or made in special material on request. • Spray patterns are available on request.

32mm Type A Drencher • 1 ⁄ 2” NPT


A Temperature Part No. Part No.
K Factor K Factor
°C A Ø - 6mm A Ø - 10mm
- 28592 25 28593 43
57° C 28555 25 28560 43
68° C 27007 25 27008 43
53mm 79° C 28556 25 27038 43
93° C 28557 25 28561 43
141° C 28558 25 28562 43
Min. 1.4 Bar [20 Psi]

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–174
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Nozzles and Accessories
Window
Window Wall Drencher Nozzle
1
Thread Size ⁄2" NPT

Spray Angles 125°

Nozzle Finish Bronze: Natural Finish

Tech Data Sheet Contact Tyco Fire Products for more Information

Nozzles can be coated or made in special material on request. • Spray patterns are available on request.

MV-R • 1 ⁄ 2” NPT
Model
Ø mm K Factor
No.
42mm 26438 6 24
26439 10 40
57.5mm Min. 1.4 Bar [20 Psi]

17.5mm

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–175
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Nozzles and Accessories


Issue A & B
Exposure Protection Nozzle

Issue A: 1 ⁄2" NPT


Thread Size
Issue B: 1 ⁄2" and 3 ⁄4" NPT
Issue B
Approvals UL, FM

1
Orifice Size - Issue A ⁄4", 5 ⁄ 16", and 3 ⁄ 8"

1
Orifice Size - Issue B ⁄ 2", 5 ⁄ 8", and 3 ⁄4"
Issue A
Nozzle Finish Bronze: Natural Finish

Wrench Type Adjustable Crescent Wrench

Tech Data Sheet TFP835

The Issue A and B Window Type Exposure Protection Sprinklers are intended for spraying water on window glazing at prescibed
spacings and sprinkler locations at a minimum discharge pressure of 0,48 bar (7 psi). • Exposure (Outside) Protection Sprinklers are
utilised to provide protection from exposure fires on the outside of buildings. • The smaller orifice Issue A Sprinklers are normally
used where exposure is light or moderate, the area of coverage is small, or where one horizontal line of window sprinklers is
installed at each floor. • The larger orifice Issue B Sprinklers are normally used where exposure is severe, or where one horizontal
line of sprinklers is used to protect windows at more than one floor level.

Issue A, 1 ⁄ 2" NPT

Issue A & B • 1 ⁄ 2” NPT


42,9 mm Approvals
K Factor
(1-11/16") & Listings
Model Orifice
Part No.
No. Size

FM
LPM GPM
UL

1
492001001 ⁄4 ” 26,33 1.83 √ √
36,5 mm 492001002 5
⁄ 16” 37,72 2.62 √ √
Issue A
(1-7/16") 3
492001003 ⁄ 8” 58,73 4.08 √ √
1
492011004 ⁄ 2” 82,93 5.76 √ √
5
Issue B 492011005 ⁄ 8” 124,39 8.64 √ √
3
492011006 ⁄4 ” 178,39 12.39 √ √
Min. 1.4 Bar [20 psi]

Issue B, 1 ⁄ 2" NPT Issue B, 3 ⁄4" NPT

3/4"
NPT

69,9 mm 77,8 mm
(2-3/4") (3-1/16")

73,0 mm
(2-7/8") 82,6 mm
(3-1/4")
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–176
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Nozzles and Accessories
D3
Protectospray Directional Spray Nozzle
K Factor K= 17,3 to 103,7 (1.2 to 7.2)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, FM

Spray Angles 65°, 80°, 95°, 110°, 125°, 140°, 160°, and 180°

Bronze: Natural Finish, Teflon Coated, Lead Coated,


Nozzle Finish
Chrome, or Natural Stainless Steel

Wrench Type W-Type 11

Tech Data Sheet TFP802, Blow-off Plugs TFP890

Designed for use in water spray fixed systems for fire protection applications • Open orifice type for use in deluge systems •
Nozzles are external deflector types that discharge a uniformly filled cone of medium velocity water droplets • Blow-Off Plugs are
available and designed for both indoor or outdoor use.

D3, 1 ⁄ 2" NPT D3 • 1 ⁄ 2" NPT • TFP802


Ø Minimum
K-Factor Approvals & Listings
Diameter
44,5 mm

Academy
of Russia
(1-3/4") Part No.

CNBOP

TSU
Fire
FM
mm In. LPM GPM

UL
No. 16 5.16 0.203 17.3 1.2 √ √ √ √ √
52,4 mm No. 18 6.35 0.250 25.9 1.8 √ √ √ √ √
(2-1/16") No. 21 7.14 0.281 33.1 2.3 √ √ √ √ √
No. 24 8.33 0.328 43.2 3.0 √ √ √ √ √
63,5 mm No. 28 9.53 0.375 59.0 4.1 √ √ √ √ √
(2-1/2") No. 32 11.13 0.438 80.6 5.6 √ √ √ √ √
No. 34 12.7 0.500 103.7 7.2 √ √ √ √ √

P/N* 49 — 3XX — X — XXX

SPRAY ANGLE
ORIFICE SIZE FINISH & MATERIAL
065 65°
16 NO. 16 1 NATURAL FINISH BRONZE
080 80°
18 NO. 18 4 TEFLON COATED BRONZE
095 95°
21 NO. 21 7 LEAD COATED BRONZE
110 110°
24 NO. 24 9 CHROME PLATED BRONZE
125 125°
28 NO. 28 0 NATURAL FINISH STAINLESS STEEL
140 140°
32 NO. 32
160 160°
34 NO. 34
* 180 180°
for example, 49-321-1-110-I

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–177
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Nozzles and Accessories


D3S
Protectospray Directional Spray Nozzle
K Factor K= 15,8 to 40,3 (1.1 to 2.8)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, FM

Nozzle Finish Bronze, Chrome Plated, or Stainless Steel

Wrench Type W-Type 11

Tech Data Sheet TFP804

The D3S Nozzles that are typically used in non-NFPA installations feature an integral strainer for use when the Authority Having
Jurisdiction requires the use of individual strainers • The D3S Nozzles are external deflector type nozzles that discharge a uniformly
filled cone of medium velocity water droplets.

D3S, 1 ⁄ 2" NPT D3S • 1 ⁄ 2" NPT • TFP804


Ø Minimum
K-Factor Approvals & Listings
Diameter
44,5 mm
(1-3/4") Part No.

FM
mm In. LPM/bar½ GPM/psi½

UL
No. 16 5.16 0.203 15,8 1.1 √ √
52,4 mm No. 18 6.35 0.250 23,0 1.6 √ √
(2-1/16")
No. 21 7.14 0.281 30,2 2.1 √ √
No. 24 8.33 0.328 40,3 2.8 √ √
63,5 mm
(2-1/2")

17,5 mm
(11/16")

P/N 49 – 5X X – X – XXX
Spray Angle

065 65°
Orifice Size FINISH & MATERIAL
080 80°
16 No. 16 1 NATURAL FINISH BRONZE
095 95°
18 No. 18 9 CHROME PLATED BRONZE
110 110°
21 No. 21 0 NATURAL FINISH STAINLESS STEEL
125 125°
24 No. 24
140 140°

160 160°

180 180°

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–178
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Nozzles and Accessories
HV ”High Velocity”
Directional Spray Nozzle
K= 23,0 (1.6) • K= 25,9 (1.8) • K= 41,8 (2.9) •
K Factor
K= 62,0 (4.3) K= 80,7 (5.6) • K= 92,2 (6.4)

Thread Size 1" NPT or 1-1 ⁄4"NPT (only K=6.4)

Approvals UL, C-UL, FM

Nozzle Finish Natural Brass or Stainless Steel

Wrench Type Adjustable Crescent Wrench

Tech Data Sheet TFP815

Open, directional spray nozzles • Designed for use in fixed water spray fire protection systems where a high velocity water
application is needed, such as the protection of flammable liquids, electrical transformers, circuit breakers, oil-fired boilers and
lube oil systems • Available in six different orifice sizes and six angle spray patterns • Produces a solid conical spray pattern

HV • TFP815
Approvals &
Part No. - NPT Part No. - ISO 7-1 K-Factor Dimensions mm
Strainer Listings
G
Type Stainless Stainless Hole
BSPT

SAS

FM
Bronze Steel Bronze Steel Size LPM GPM A B C D

UL
Type 316 Type 316
HV14 490141001 490140001 PBP55062 AEC00012 1” 2,4 (3/32") 23,0 1.6 71 47.6 38,1 33,0 √ √ √
HV17 490171001 490170001 PBP55071 AEC00021 1” 2,4 (3/32") 25,9 1.8 72 47.6 38,1 33,0 √ √ √
HV26 490261001 490260001 PBP55080 AEC00030 1” 2,4 (3/32") 41,8 2.9 71.5 47.6 38,1 33,0 √ √ √
HV37 490371001 490370001 PBP55099 AEC00049 1” 3,2 (1 ⁄ 8") 62,0 4.3 75.2 51.6 38,1 33,0 √ √ √
HV45 490451001 490450001 PBP55101 AEC00058 1” 3,2 (1 ⁄ 8") 80,7 5.6 75.6 51.6 38,1 33,0 √ √ √
HV60 490601001 490600001 AEC00236 AEC00263 1-1 ⁄4” 3,2 (1 ⁄ 8") 92,2 6.4 15.5 86.5 48,3 41,9 √ √ √

A
D
B

Strainer
Hole Size G BSPT

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–179
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Nozzles and Accessories


EA-1
Automatic Protectospray Directional Spray Nozzle
K Factor K= 20,2 (1.4), K= 40,3 (2.8), K= 80,6 (5.6)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, FM


57°C (135°F), 79°C (175°F), 121°C (250°F),
Temperature
163°C (325°F), 204°C (400°F), 260°C (500°F)
Spray Angles 65°, 80°, 95°, 110°, 125°, 140°, 160°, and 180°
Natural Finish Bronze, Lead Coated Bronze,
Sprinkler Finish
Chrome Plated, Wax Coated Bronze
Wrench Type W-TYPE 11

Tech Data Sheet TFP800

Medium velocity, Bulb type frangible element for use in closed head systems • Discharges a filled cone of water droplets at
relatively low velocity • The Type EA-1 Nozzles are also especially effective for area coverage and are sometimes used in lieu of
standard sprinklers where directional spray is considered more appropriate.

EA-1, 1 ⁄ 2" NPT


EA-1 • 1 ⁄ 2" NPT • TFP800
Ø Minimum
(1-3/4") K-Factor Approvals & Listings
Diameter
44,5 mm
Part No.

FM
mm In. LPM/bar½ GPM/psi½

UL
No. 7 6 [1 ⁄4] 20.2 [1.4] √ √
No. 8 10 [3 ⁄ 8] 40.3 [2.8] √ √
No. 9 15 [1 ⁄ 2] 80.6 [5.6] √ √
76,2 mm
(3")

87,3 mm
(3-7/16")

P/N 49 – XXX – X – XX X
TEMPERATURE
RATING
(ALL FINISHES)

K-FACTOR 135 135°F (57°C)


SPRAY ANGLE FINISH and MATERIAL
7 K = 1.4 65 65° 175 175°F (79°C)
1 NATURAL FINISH BRONZE
8 K = 2.8 80 80° 250 250°F (121°C)
WAX COATED BRONZE
9 K = 5.6 6 325 325°F (163°C)
95 95° 135°F to 175°F ONLY

10 110° LEAD COATED BRONZE


7 TEMPERATURE
135°F to 325°F ONLY
RATING
25 125°
(NATURAL
9 CHROME PLATED BRONZE FINISH BRONZE
40 140°
ONLY)
60 160° 400 400°F (204°C)

81 180° 500 500°F (260°C)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–180
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Nozzles and Accessories
TN-25
Horizontal Spray Nozzle, Open
K Factor K= 363 (25.2)

Thread Size 1" NPT or ISO 7-R 1

Approvals UL, C-UL

Nozzle Finish Natural Brass

Wrench Type W-Type 1

Tech Data Sheet TFP850

The TYCO Model TN-25 Horizontal Spray Nozzle is a specialised open nozzle for use in tunnel fire protection deluge systems,
providing an improved alternative to traditional designs • Model TN-25 Nozzle allows for a single pipe to run the length of a tunnel,
compared to traditional designs that use multiple pipes in order to provide sufficient coverage.

TN-25, 1" NPT or ISO 7-R 1

K=363 (25.2) • 1" NPT or ISO 7-R 1 • TFP850


Part No. Approvals & Listings
Finish
1" NPT ISO 7-R 1 Code

UL
52,4 mm
(2-1/16")
490251001 490251002 1 √

22,2 mm
(7/8")

95,3 mm
(3-3/4")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–181
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Nozzles and Accessories


TN-17
Horizontal Spray Nozzle, Open
K Factor K= 242 (16.8)
3
Thread Size ⁄4" NPT or ISO 7-R 3 ⁄4

Approvals UL, C-UL

Nozzle Finish Natural Brass

Wrench Type W-Type 21

Tech Data Sheet TFP852

The TYCO Model TN-17 Horizontal Spray Nozzle having a 240 (16.8) K-factor is a specialised open nozzle for use in tunnel fire
protection deluge systems, providing an improved alternative to traditional designs • With its ability to provide extended coverage,
the Model TN-17 Nozzle allows for a single pipe to run the length of a tunnel, compared to traditional designs that use multiple
pipes in order to provide sufficient coverage • The Model TN-17 Nozzle is an open nozzle designed to be integrated into a deluge
fire protection system.

TN-17, 3 ⁄4" NPT or ISO 7-R 3 ⁄4

K=242 (16.8) • 3 ⁄4" NPT or ISO 7-R 3 ⁄4 • TFP852


Part No. Approvals & Listings
52,4 mm Finish
(2-1/16") 3
⁄4" NPT ISO 7-R 3 ⁄4 Code

UL
490172002 490172001 1 √

19,1 mm
(3/4")

95,3 mm
(3-3/4")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–182
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Nozzles and Accessories
D4a
Directional Spray Nozzles, Open, Medium Velocity
K= 17,3 (1.2) • K= 25,9 (1.8) • K= 33,1 (2.3) • K= 43,2 (3.0)
K Factor
K= 59,0 (4.1) • K= 80,6 (5.6) • K= 103,7 (7.2)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL

Spray Angles 65°, 80°, 95°, 110°, 125°, 140°, 160°, and 180°

Nozzle Finish Natural Finish Bronze, Teflon Coated Bronze

Wrench Type Common Adjustable Wrench

Tech Data Sheet TFP806

Nozzles are external deflector types that discharge a uniformly filled cone of medium velocity water droplets • The Type D4a
Nozzles feature a four arm body design that helps assist against mechanical or physical damage • Open orifice design type for use
in deluge systems

D4a, 1 ⁄ 2" NPT


D4a • 1 ⁄ 2" NPT • TFP806
Ø Minimum Approvals &
42,9 mm K-Factor
Diameter Listings
(1.69")
Part No.
In. mm LPM/bar½ GPM/psi½

UL
NO. 16 0.203" 5,16 mm 1.2 17,3 √
NO. 18 0.250" 6,35 mm 1.8 25,9 √
59,4 mm NO. 21 0.281" 7,14 mm 2.3 33,1 √
(2.43") NO. 24 0.328" 8,33 mm 3.0 43,2 √
NO. 28 0.375" 9,53 mm 4.1 59,0 √
NO. 32 0.438" 11,13 mm 5.6 80,6 √
NO. 34 0.500" 12,70 mm 7.2 103,7 √

P/N 49 – 4X X – X – XXX
SPRAY ANGLE

ORIFICE SIZE 065 65°


FINISH & MATERIAL
16 No. 16 080 80°
1 Natural Finish Bronze
18 No. 18 095 95°
4 TEFLON Coated Bronze
21 No. 21 110 110°

24 No. 24 125 125°

28 No. 28 140 140°

32 No. 32 160 160°

34 No. 34 180 180°

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–183
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Nozzles and Accessories


F822 thru F834 Mulsifyre®
Directional Spray Nozzles, Open, High Velocity
K= 28,8 (2.0) • K= 33,1 (2.3) • K= 38,9 (2.7)
K Factor
K= 37,4 (2.6) • K= 66,2 (4.6) • K= 73,4 (5.1)
3
Thread Size ⁄4" NPT

Approvals UL, ULC

Nozzle Finish Brass

Wrench Type Common Adjustable Wrench

Tech Data Sheet TFP810

Two configurations: basic Mulsifyre Nozzle & Mulsifyre Nozzle with Model F880 Dust Cap, • Available in six different models provide
a wide range of orifice sizes and water distribution characteristics • Air aspirating foam-water nozzles, for use with all types of
foam (required for Non-AFFF type foams) • Designed for use in water spray fixed systems for fire protection applications where a
high velocity water application may be required, Pendent & upright designs, Open nozzle for use on deluge systems.

3
⁄4" NPT • TFP810
F822 - F834, 3 ⁄4" NPT
Dimensions Approvals
Part Number. K-Factor
mm & Listings
Model
Mulsifyre
No. Mulsifyre
Nozzle NFPA ISO/SI A B

UL
Nozzle
with Dust Cap
F822 498001822 498011822 2.0 28,8 42 28,6 √
F824 498001824 498011824 2.3 33,1 42 28,6 √
A F826 498001826 498011826 2.6 37,4 42 28,6 √
B F828 498001828 498011828 2.7 38,9 43 30,2 √
F832 498001832 498011832 4.6 66,2 47 33,3 √
F834 498001834 498011834 5.1 73,4 70 57,2 √

1" DIA.
(25,4 mm)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–184
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Nozzles and Accessories
F822S thru F834S Mulsifyre®
Directional Spray Nozzles, Open, With Strainers, High Velocity
K Factor See Chart Below
3
Thread Size ⁄4" NPT

Approvals FM

Nozzle Finish Brass

Wrench Type Common Adjustable Wrench

Tech Data Sheet TFP811

Two configurations: basic Mulsifyre Nozzle & Mulsifyre Nozzle with Model F880 Dust Cap, • Available in six different models provide
a wide range of orifice sizes and water distribution characteristics • Air aspirating foam-water nozzles, for use with all types of
foam (required for Non-AFFF type foams) • Designed for use in water spray fixed systems for fire protection applications where a
high velocity water application may be required, Pendent & upright designs, Open nozzle for use on deluge systems.

F822S - F834S, 3 ⁄4" NPT

47,6 mm
(1-7/8")

25,4 mm
(1")

3
⁄4" NPT • TFP811
K-Factor ISO K-Factor Approvals &
Part No. Dimensions mm
lpm/bar½ gpm/psi½ Listings
Model Nominal
No. Mulsifyre Spray Angle 1,70-4,1 4,2-12,0 25-60 61-175
FM

A B
Nozzle bar bar psi psi

F822 498101822 80° 28,8 27,4 2.0 1.9 79,4 33,3 √


F824 498101824 70° 34,6 33,1 2.4 2.3b 79,4 33,3 √
F826 498101826 125° 37,4 36,0 2.6a 2.5 79,4 33,3 √
F828 498101828 70° 38,9 36,0 2.7 2.5 82,6 34,9 √
F832 498101832 90° 66,2 60,5 4.6 4.2 85,7 38,1 √
F834 498101834 70° 67,7 60,5 4.7 4.2 109,5 61,9 √
Nominal range of K-factors is ± 5% except where noted:
a. Add ± 1%
b. Add ± 2%

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–185
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Nozzles and Accessories


Cooling Tower Nozzle
Type 1 and 2
K Factor K= 42,0 (2.9)
3
Thread Size ⁄4" NPT

Approvals UL, FM

Nozzle Finish Bronze or Stainless Steel

Wrench Type W-Type 11

Tech Data Sheet TFP830

Intended for use in fire protection systems for cross flow cooling towers with combustible fill sections • Open nozzle design for use
in water spray deluge system • Installed under the distribution basin, they discharge water in a relatively narrow, elongated spray
pattern • Type 1 has a waterway designed for use in towers with diffusion decks, Type 2 for those without diffusion decks

3
⁄4" NPT • TFP830
Cooling Tower, 3 ⁄4" NPT
Part No. Approvals & Listings

44,5 mm Model
Stainless

FM
No. Bronze

UL
(1-3/4") Steel

Type 1 500811000 500810001  √


Type 2 500821001 500820001  √
√=Both Materials Approved
 Bronze Only

76,2 mm
(3")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–186
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Nozzles and Accessories
B-1

Upright & Pendent Foam-Water Sprinkler


K Factor K= 43 (3.0)
1
Thread Size ⁄2" NPT

Approvals UL, C-UL, Military

Nozzle Finish Natural Bronze

Wrench Type Common Adjustable Wrench

Tech Data Sheet TFP840

Air aspirating foam-water nozzles • Pendent & upright styles • Open nozzle for use in NFPA 16 foam-water sprinkler systems

1
⁄ 2" NPT • TFP840
B-1, 1 ⁄ 2" NPT
Part No. Approvals & Listings
54,0 mm

PAVUS

TSU
Upright Pendent

UL
(2-1/8")

492101001 492111001 √ √ √

147,6 mm 150,8 mm
(5-13/16") (5-15/16")

54,0 mm
(2-1/8")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 1–187
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Nozzles and Accessories


Notes

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

1–188
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Watermist System
AquaMist systems are a versatile and highly efficient fire-fighting resource, featuring unique nozzles, which
have been designed and rigorously tested to protect against a wide range of fire risks.

- Hotels - Turbine

- Hospitals - Cable Tunnel

- Data Center - Libraries and Archives

- Heritage - Industrial Fryer Protection (IFP)

- Machinery Space - Offices

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 2-1
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Watermist System
Aquamist ULF System
Ultra Low Flow

A complete engineered solution including pumps, valves,


discharge nozzles, pipes and fittings, all designed to
function as one dedicated fire protection system.
The system operates at working pressures of 7 to 12 bar,
producing droplets of water through a range of nozzles,
specifically engineered and approved for a variety of fire
hazards.
AquaMist ULF systems are supplied through authorized
partners. The ULF system is suitable for a variety of
applications, including machinery protection, data
centers, cable tunnels, offices, hotels and industrial fryers.
The AquaMist ULF training modules provide complete
design, technical, commercial and life cycle knowledge.
Authorized partners are fully supported by our technical
services team and all fire suppression products are
manufactured to the highest quality.
Benefits of a low pressure Water Mist system include
lower water demands, translating into lower pressure
losses, smaller diameter pipes and lower installation costs
when compared to traditional sprinkler systems. As the
system uses only water without additives, it produces no
adverse environmental impact.
Benefits:
• Equally as effective as high pressure solutions
• Lower electrical requirements
• No high pressure piping and fittings
• Suitable for stand-alone solutions and installations
with limited electricity supply

Droplet Sizes

100-200 µm
1,000 µm
ULF
Sprinkler

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

2-2
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Watermist System
Aquamist FOG System
High Pressure

FOG
AquaMist FOG systems reduce the consumption of water
and pipe diameters required whilst providing a fast and
efficient method of fire protection for class A and B fires.
AquaMist FOG provides outstanding fire suppression
protection for turbine and transformer rooms, engine test
cells, diesel engines and alternators, paint spray booths
and mechanical escalators
The system operates at working pressures of 70 to 200 bar
to produce droplets of water with small diameters, which
discharge at high speeds. For each different protected
hazard, optimized nozzles have been developed and
tested. AquaMist FOG is based on principles of well-
established hydraulic technology. Spray heads are
designed to discharge water in the form of Water Mist,
with tiny droplets creating a large effective cooling
surface area of the fire and surrounding volume. The high
speed of the droplets allows the mist to penetrate the hot
fumes and reach the combustion area quickly. AquaMist
FOG systems are available as either a pre-engineered
cylinder system or engineered pumped system, and
provide a versatile fire protection solution.
AquaMist FOG systems are one of the best options
when piping dimensions or pressure losses are critical,
for example in applications such as heritage buildings,
libraries and archives, where fragile structures require
preserving from water damage.
Benefits:
• Ideal when piping dimensions are a problem
• Ideal when pressure losses are critical
• Quick discharge of Water Mist on combustible areas

Droplet Sizes

50 µm
FOG 1,000 µm
Sprinkler

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 2-3
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Watermist System
Aquamist Sonic System
Twin Fluid

SONIC
The AquaMist SONIC system is a revolution in Class B fire
protection and features 100% machined stainless steel
construction for superior strength, no internal moving
parts for extreme dependability and multiple mounting
options for ease of installation.
The system is fast extinguishing with high-volume,
high-velocity discharge which quickly fills spaces. It
is also more efficient and uses one-third the water of
comparable high pressure systems. As operating pressure
is under 8 bar, this proves that one does not need high
pressure to generate the smallest droplet sizes. This
system is listed and approved for the protection of
flammable liquid hazards (FM) and extinguished all fire
scenarios in the FM Protocol 5580. It is FM approved for
spaces ranging from 4,591 to 36,727 cubic feet (volumes
up to 1,040 cubic metres).
This system utilizes non-toxic and readily available
extinguishing media (water and nitrogen). The AquaMist
SONIC twin-fluid technology is safe for people and is
environmentally friendly. It is constructed of industry
proven, components including an ASME/ TPED approved
stainless steel water storage tank. Capable of automatic
detection and actuation and/or remote manual actuation,
the system is installed and serviced by authorized
distributors. Just two supersonic atomizers create 1.5
trillion superfine water droplets per second, producing
a combined surface area of 121 m2 (1302 ft2). This is
equivalent to covering the surface of an Olympic-size
soccer field in one minute. Additionally, the atomizers
propel the droplets at high velocity throughout the
combustion zone providing rapid fire knock-down. The
atomizer is the key to the effectiveness of the AquaMist
Sonic system. Supersonic technology generates a
high-velocity, low-pressure zone that draws a thin
sheet of water into a primary atomization region. A
conical supersonic wave then creates a zone of extreme
acceleration and high shear-rate, breaking the sheet into
atomized droplets.
Benefits:
• Provides a solution to ventilation
• Facilitates protection of higher height risks Droplet Sizes
• Can protect highly-obstructed areas
• Protects volumes without the need for 10 µm
power or pump arrangement SONIC 1,000 µm
Sprinkler

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

2-4
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Wet Pipe Sprinkler Systems
Designed for use in wet pipe sprinkler systems.

- Heated Warehouses - Apartment or Condominium


Complexes
- Factories
- Single Family Residences
- Hospitals

- Shopping Centers

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–1
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Wet System Valves & Devices

AV-1 Alarm Valve

BFV-300 Butterfly Valve


to Control Water Supply
to System

Water Supply

AV-1-300
Alarm Valve
Size Range DN65 thru DN200 (21 ⁄ 2" thru 8")

Approvals UL, C-UL Listed & FM Approved

Working Water
1,4 to 20,7 bar (20 to 300 psi)
Pressure

For use in wet pipe (automatic sprinkler) fire


System
protection systems

End Connection Groove x Groove, Flange x Flange, Flange x Groove

Flange Drilling ANSI, ISO, AS, & JIS

Tech Data Sheet TFP910

AV-1-300 Alarm Valves may be installed vertically or horizontally • Alarm Valves are divided seat ring, rubber-faced clapper, water
flow alarm valves • Automatically actuates electrically and/or hydraulically operated alarms when there is a steady flow equivalent
to the discharge rate for one or more sprinklers • Optional Retard Chamber used in installations subject to variable pressure
(generally associated with public water supplies) to help prevent false alarms • Available pre-assembled with modular trim to
provide a quick and convenient method for trimming valve risers. Refer to TFP for details

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–2
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Wet System Valves & Devices
AV-1-300

H H H

Groove x Groove (GxG) Flange x Flange (FxF) Groove x Flange (GxF)


Max. 20.7 Bar [300 Psi] Max. Pressure depends Max. Pressure depends
on Flange Type on Flange Type

AV-1-300 Alarm Valve • TFP910


Size Approvals & Listings
H Weight

VNIIPO
Part No. Ends Flanges Drain

LPCB
VdS*

FM
DN In. mm kg

UL
CE
522034120 65 [76,1mm] 2-1/2” 225 GxG - 1-1 ⁄ 2” 10 √ √ √ √
522031923 100 4” 260 GxG - 2” BSP 20.4 √ √ √ √ √ √
522031925 150 [168,3mm] 6” 311 GxG - 2” BSP 30.9 √ √ √ √ √ √
522031125 150 [165,1mm] 6” 311 GxG - 2” BSP 30.9 √ √ √ √ √ √
522031926 200 8” 356 GxG - 2” BSP 58.6 √ √ √ √ √ √
522034113 100 4” 254 FxF PN 10/16 2” BSP 28.1 √ √ √ √ √ √
522031013 100 4” 254 FxF ANSI 125 2” NPT 28.1 √ √ √ √ √
522034115 150 6” 305 FxF PN 10/16 2” BSP 42.2 √ √ √ √ √ √
522031015 150 6” 305 FxF ANSI 125 2” NPT 42.2 √ √ √ √ √
522034116 200 8” 356 FxF PN 10 2” BSP 75.8 √ √ √ √ √ √
522034117 200 8” 356 FxF PN 16 2” BSP 75.8 √ √ √ √ √ √
522031016 200 8” 356 FxF ANSI 125 2” NPT 75.8 √ √ √ √ √
522031311 65 2-1 ⁄ 2” [76,1mm] 225 GxF PN 10/16 1-1 ⁄ 2” BSP 12.7 √ √ √
522031220 65 2-1 ⁄ 2” [76,1mm] 225 GxF ANSI 125 1-1 ⁄ 2” NPT 12.7 √ √ √
522034213 100 4” 254 GxF PN 10/16 2” BSP 23.1 √ √ √ √ √ √
522031413 100 4” 254 GxF ANSI 125 2” BSP 23.1 √ √ √ √ √
522034215 150 6” [168,3mm] 305 GxF PN 10/16 2” BSP 35.4 √ √ √ √ √ √
522031615 150 6” [168,3mm] 305 GxF ANSI 125 2” NPT 35.4 √ √ √ √ √
522034216 200 8” 356 GxF PN 10 2” BSP 67.1 √ √ √ √ √ √
522034226 200 8” 356 GxF PN 16 2” BSP 67.1 √ √ √ √ √ √
522031816 200 8” 356 GxF ANSI 125 2” NPT 67.1 √ √ √ √ √
*VdS only in combination with VdS approved Trim

FM Trims Galvanized
Size
Part No. Drain
DN In.
522042050 65 2-1/2” Closed
522042951E 100, 150 4”, 6” Closed
522042952E 200 8” Closed

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–3
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Wet System Valves & Devices


AV-1-300 Wet System Valve Assemblies with FM Trim

Standard Assembly:
Wet Alarm Valve [AV-1-300]
Retarding Chamber [RC-1]
Pressure Alarm Switch [PS10-1]
No Stop Valve *
*For Stop Valve see chapter 3, needs to be ordered separately

F
E
G
C
A H
B

AV-1-300 Wet System Valve Assembly with FM Trim - TFP910


Dimensions mm
Size Weight
Part No. Inlet Outlet A B C D E F G H
DN kg
mm mm mm mm mm mm mm mm
1147200101 100 [114,3 mm] 4” GRV GRV 500 300 215 280 160 530 254 80 38
1447200101 100 4” PN 10/16 PN 10/16 500 300 215 280 160 530 254 80 45
1167200101 150 [168,3 mm] 6" GRV GRV 520 310 240 300 190 550 305 75 48
1467200101 150 6” PN 10/16 PN 10/16 520 310 240 300 190 550 305 75 59
1187200101 200 [219,1 mm] 8” GRV GRV 520 340 260 340 230 560 356 60 76
1487200101 200 8” PN10 PN10 520 340 260 340 230 560 356 60 75
1587200101 200 8” PN 16 PN 16 520 340 260 340 230 560 356 60 93
Other options available on request

B.9 Pos. Description


B.8 A Wet Alarm Valve AV-1-300
B Alarm Valve Trim, including:
B.10 D
B.1 Main Drain Valve
A
B.2 Alarm Test Valve
B.10 B B.3 Alarm Control Valve
B.4 Strainer
B.2 B.11
B.5 Swing Check Valve
B.6 5,6 mm Orifice Restriction
B.1 C
B.7 3,2 mm Orifice Restriction
B.8 Supply Pressure Gauge
B.9 System Pressure Gauge
B.10 Gauge Test Valve
B.3 B.11 Watermotor Alarm/Vent Trim Connection
C Retarding Chamber RC-1
B.5 B.6 D Pressure Alarm Switch PS10-1
B.4

B.7

B.5

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–4
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Wet System Valves & Devices
AV-1-300 Wet System Valve Assemblies with CE/FM Trim
Standard Assembly:
Wet Alarm Valve [AV-1-300]
Retarding Chamber [RC-1]
Pressure Alarm Switch [PS10-1]
*For Stop Valve see chapter 3, needs to be ordered separately E

C D
B

AV-1-300 Wet System Valve Assembly with CE/FM Trim - TFP990


Dimensions mm Approval Listings

Belarusian
Ukrainian

Academy
of Russia
Weight
Part No. DN Inlet Outlet

LPCB
VdS

Fire
FM
kg

EN
A B C D E

CE
1108900101 65 76,1mm 2-1 ⁄ 2” GRV GRV 310 390 266 320 745 31 √ √ √ √ √ √ √ √
1608900101 65 2-1 ⁄ 2” PN 10/16 GRV 310 390 266 320 745 33 √ √ √ √ √ √ √ √
1148900101 100 114,3mm 4” GRV GRV 315 340 216 260 760 38 √ √ √ √ √ √ √ √
1648900101 100 4” PN 10/16 GRV 315 340 216 260 760 41 √ √ √ √ √ √ √ √
1448900101 100 4” PN 10/16 PN 10/16 315 340 216 260 760 46 √ √ √ √ √ √ √ √
1168900101 150 168,3mm 6” GRV GRV 340 360 236 285 770 49 √ √ √ √ √ √ √ √
1668900101 150 6” PN 10/16 GRV 340 360 236 285 770 54 √ √ √ √ √ √ √ √
1468900101 150 6” PN 10/16 PN 10/16 340 360 236 285 770 60 √ √ √ √ √ √ √ √
1188900101 200 219,1mm 8” GRV GRV 410 390 266 405 770 78 √ √ √ √ √ √ √ √
1688900101 200 8” PN 16 GRV 410 390 266 405 770 86 √ √ √ √ √ √ √ √
1588900101 200 8” PN 16 PN 16 410 390 266 405 770 95 √ √ √ √ √ √ √ √
Other options available on request

D Pos. Description
B.10
B.5 A Wet Alarm Valve AV-1-300
B Alarm Valve Trim, including:
B.1 Test & Drain Valve
C
B.2 3,6 mm Orifice Restriction
B.3 K=5 Orifice Restriction
B.4 Strainer
B.5 Alarm Control Valve
B.6 Swing Check Valve
B.7 B.8
B.7 System Pressure Gauge
B.8 Supply Pressure Gauge
B.9 B.9 Gauge Test Valve
B.2
B.10 Watermotor Alarm/Vent Trim Connection
B.4 C Retarding Chamber RC-1
A
B.3 D Pressure Alarm Switch PS10-1

B.6 B

B.1

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–5
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Wet System Valves & Devices


AV-1-300 Supervised Wet System Valve Assemblies with CE/FM Trim
Standard Assembly:
Wet Alarm Valve [AV-1-300]
Retarding Chamber [RC-1]
Pressure Alarm Switch [PS10-1]
Ball Valve
E
*For Stop Valve see chapter 3, needs to be ordered separately

C D
B

AV-1-300 Supervised Wet System Valve Assembly with CE/FM Trim - TFP990
Dimensions mm Approval Listings

Belarusian
Ukrainian

Academy
of Russia
Weight
Part No. DN Inlet Outlet

LPCB
VdS

Fire
FM
kg

EN
A B C D E

CE
1108800105 65 76,1mm 2-1/2” GRV GRV 315 390 266 320 830 31 √ √ √ √ √ √ √ √
1608800105 65 2-1/2” PN 10/16 GRV 315 390 266 320 830 33 √ √ √ √ √ √ √ √
1148800105 100 114,3mm 4” GRV GRV 315 340 216 260 830 38 √ √ √ √ √ √ √ √
1648800105 100 4” PN 10/16 GRV 315 340 216 260 830 41 √ √ √ √ √ √ √ √
1448800105 100 4” PN 10/16 PN 10/16 315 340 216 260 830 46 √ √ √ √ √ √ √ √
1168800105 150 168,3mm 6” GRV GRV 340 360 236 280 830 49 √ √ √ √ √ √ √ √
1668800105 150 6” PN 10/16 GRV 340 360 236 280 830 54 √ √ √ √ √ √ √ √
1468800105 150 6” PN 10/16 PN 10/16 340 360 236 280 830 60 √ √ √ √ √ √ √ √
1188800105 200 219,1mm 8” GRV GRV 410 390 266 400 830 78 √ √ √ √ √ √ √ √
1688800105 200 8” PN 16 GRV 410 390 266 400 830 86 √ √ √ √ √ √ √ √
1588800105 200 8” PN 16 PN 16 410 390 266 400 830 95 √ √ √ √ √ √ √ √
Other options available on request

D Pos. Description
A Wet Alarm Valve AV-1-300
B.10
B Alarm Valve Trim, including:
B.1 Test & Drain Valve
C
B.2 3,6 mm Orifice Restriction
B.3 K=5 Orifice Restriction
B.4 Strainer
B.5 Alarm Control Valve
B.6 Swing Check Valve
Position for supervisory switch
(ordered seperately) B.7 System Pressure Gauge
B.8 Supply Pressure Gauge
B.9 Gauge Test Valve
B.7 B.5 B.8
B.10 Water Motor Alarm/Vent Trim Connection
C Retarding Chamber RC-1
B.2
B.9 D Pressure Alarm Switch PS10-1
B.4 A
B.3

B.6 B

B.1

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–6
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Wet System Valves & Devices
AV-1-300 Wet System Valve Assemblies with CE/VdS Trim
Standard Assembly:
Wet Alarm Valve [AV-1-300]
Retarding Chamber [RC-1]
Pressure Alarm Switch [PS10-1]
Gate Valve [0547] Not Supervised
F

A
D E

AV-1-300 Wet System Valve Assembly with CE/VdS Trim - TFP990


Dimensions Approval Listings

Belarusian
Ukrainian
Weight
Part No. DN Inlet Outlet

LPCB

VKF
VdS
kg

EN
A B C D E F

CE
1608921101 65 76,1mm 2-1/2” PN10/16 GRV 154 310 390 266 320 745 57 √ √ √ √ √ √ √
1648921101 100 114,3mm 4” PN10/16 GRV 154 315 340 216 260 760 65 √ √ √ √ √ √ √
1448921101 100 4” PN10/16 PN10/16 154 315 340 216 260 760 70 √ √ √ √ √ √ √
1668921101 150 168,3mm 6” PN10/16 GRV 174 340 360 236 285 770 96 √ √ √ √ √ √ √
1468921101 150 6” PN10/16 PN10/16 174 340 360 236 285 770 103 √ √ √ √ √ √ √
1688921101 200 219,1mm 8” PN16 GRV 223 410 390 266 405 770 151 √ √ √ √ √ √ √
1488921101 200 8” PN10 PN10 223 410 390 266 405 770 159 √ √ √ √ √ √ √
1588921101 200 8” PN16 PN16 223 410 390 266 405 770 159 √ √ √ √ √ √ √
Other options available on request

D Pos. Description
B.5
A Wet Alarm Valve AV-1-300
B.10 B Alarm Valve Trim, including:
B.1 Test & Drain Valve
B.2 3,6 mm Orifice Restriction
C
B.3 K=5 Orifice Restriction
B.4 Strainer
B.5 Alarm Control Valve
B.7 B.8 B.6 Swing Check Valve
B.7 System Pressure Gauge
B.8 Supply Pressure Gauge
B.9 Gauge Test Valve
B.9
B.10 Water Motor Alarm/Vent Trim Connection
B.2 C Retarding Chamber RC-1
D Pressure Alarm Switch PS10-1
B.4 A Gate Valve 0547
B.3
E (for supervised order separately
B B.6
WS00000011)

B.1

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–7
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Wet System Valves & Devices


RC-1
Retard Chamber
UL, ULC, & FM for use with: Model AV-1-300 Alarm
Check Valves
Approvals UL, ULC, FM, VdS, & LPCB for use with the following
Alarm Check Valves: Model AV-1-175, Gem Model
F20/F200/F2001, Gem Model A, Star Model S30/
S300/S3001

Maximum Working
20,7 bar (300 psi)
Pressure

For use in a wet type automatic sprinkler


System
system riser

Tech Data Sheet TFP920

The Model RC-1 Retard Chamber is required in installations that will be subject to pressure variations, as are generally associated
with public water supplies, in order to help prevent false alarms

1/2" NPT
WATERFLOW RC-1 Retard Chamber - TFP920
PRESSURE
ALARM SWITCH Part No. Model Desc.
CONNECTION
52-211-1-002 RC-1 With Galvanized Steel Fittings
3/4" NPT WATER 3/4" x 1/2" x 3/4" 52-353-1-005 Accessoires Y-Strainer
MOTOR ALARM REDUCING TEE 92-210-1-005 Accessoires Restriction Assembly
CONNECTION
3/4" x 1-1/2"
Accessories
9-1/8" NIPPLE
(232,0 mm) Part No. Description
END-TO-END
1 GAL. 522011012E Vent Trim
(3,8 L)
522012047 Pressure Relief Trim [12,1 Bar]
NOMINAL
CAPACITY 522012048 Pressure Relief Trim [12,7 Bar]

Vent Trim PRESSURE


1/2" NPT INLET SWITCH
CONNECTION

8-1/8" 1
(206,0 mm) 3
DIA. (ROUTE TO
DRAIN)
2
MODEL RC-1 (GREEN
RETARD TINT)
CHAMBER

Pressure Relief Trim ALARM


CHECK SYSTEM
VALVE PRESSURE
GAUGE
TO DRIP
FUNNEL PRESSURE
OR OTHER RELIEF
SUITABLE CONTROL
DRAIN VALVE
(NORMALLY
OPEN)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–8
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Wet System Valves & Devices

CV-1FR
Riser Check Valve
Size Range DN50 thru DN300 (2" thru 12")

Approvals UL, C-UL Listed & FM Approved

Maximum Working
20,7 bar (300 psi)
Pressure

For use in a wet type automatic sprinkler


System
system riser

End Connection Groove x Groove

Tech Data Sheet TFP950

Can be installed using GRINNELL Grooved Couplings or GRINNELL Figure 71 Flange Adapters • Designed with a removable cover for
ease of field maintenance • Standard seal is grade “E" EPDM

A B
1/4"
1/4" NPT
NPT

O.D.

J K

F
Model CV-1 FR Riser Check Valve - Grooved - TFP950
Dimensions mm Approval & Listings
K Weight Fire
Part No. DN
A B C D E F J NPT kg FM UL Academy
(in) of Russia
595901020 50 [60,3mm] 2” 171,5 111,3 49,8 65,3 82,3 111,0 39,6 1" 4.5 √ √ √
595901025 65 [73,0mm] 2-1 ⁄ 2” 203,2 136,7 66,8 78,5 98,3 130,0 43,9 1-1 ⁄4" 4.5 √ √ √
595901076 65 [76,1mm] - 203,2 136,7 66,8 78,5 98,3 130,0 43,7 1-1 ⁄4" 4.5 √ √ √
595901030 80 [88,9mm] 3” 212,6 145,3 71,4 84,1 98,3 130,0 43,7 1-1 ⁄4" 5.0 √ √ √
595901040 100[114,3mm] 4” 245,6 169,7 96,5 92,2 115,4 146,8 53,8 2" 11.3 √ √ √
595901139 125 [139,7mm] 5” 266,7 188,0 113,2 104,9 124,5 177,8 53,1 2" 13.2 √ √ √
595901050 125 [141,3mm] 5” 266,7 188,0 113,2 104,9 124,5 177,8 53,1 2" 13.2 √ √ √
595901165 150 [165,1mm] - 292,1 203,2 117,4 114,3 127,0 184,2 50,8 2" 21.3 √ √ √
595901060 150[168,3mm] 6” 292,1 203,2 117,4 114,3 127,0 184,2 50,8 2" 21.3 √ √ √
595901080 200 [219,1mm] 8” 355,6 257,6 169,4 140,2 138,7 266,7 61,7 2" 30.0 √ √ √
595901100 250 [273,1mm] 10" 457,2 314,5 218,9 162,8 190,5 273,1 85,9 2" 49.4 √ √ √
595901120 300 [323,9mm] 12" 533,4 362,7 252,2 184,7 193,5 254,0 79,5 2" 68.0 √ √ √

FM Trims Galvanized
Part No. DN
595911020 50 2"
595911030 65, 80 2-1 ⁄ 2", 3"
595911080 100, 125, 150, 200 4", 5", 6", 8"

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–9
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Wet System Valves & Devices


RSV-1
Residential Shut Off Valve
NFPA 13D - DN25 (1")
Size Range
NFPA 13R or NFPA 12D - DN50 (2")

Approvals UL, C-UL, & NSF-61

Maximum Working
12,1 bar (175 psi)
Pressure

System For use in residential sprinkler systems

End Connection Thread x Thread

Tech Data Sheet TFP980

During the design of a residential sprinkler system, domestic water use should be taken into consideration unless the domestic
supply can be stopped when a sprinkler operates • When a sprinkler operates, water supply is automatically diverted from the
domestic system to the sprinkler system • Eliminates the need for pumps, pressurized storage tanks, or electrically operated
domestic shutoff valves • Valve automatically resets after the fire protection system is returned to normal service

B.4
136,5 mm FIRE
92,1 mm FIRE (5-3/8") DIA. SPRINKLER
(3-5/8") DIA. SPRINKLER PORT, 2" NPT
PORT, 1" NPT B.5

DOMESTIC
PORT,
DOMESTIC 82,6 mm 2" NPT
PORT, (3-1/4") 114,3 mm
1" NPT (4-1/2")
B.2

208,0 mm 230,2 mm
(8-3/16") (9-1/16") D
125,4 mm
(4-15/16") 115,9 mm A
(4-9/16")

WATER B.1
SUPPLY 60,3 mm WATER
PORT, 1" NPT (2-3/8") SUPPLY 95,3 mm
PORT, 2" NPT (3-3/4")
B.3

Model RSV-1 Residential Shut-Off Valve - TFP980 B.5


Ends Approval & Listings
Part No. Type DN
Inlet Outlet FM UL C
52-540-1-001 Residential 25 1" FPT FPT √ √
52-540-1-002 Residential 50 2" FPT FPT √ √
Pos. Description
A Shut Off Valve
B Shut Off Valve Trim:
B.1 Domestic System
B.2 Drain & Test
B.3 Supply Pressure Gauge
B.4 System Pressure Gauge
B.5 Gauge Test Valve
C Main Control Valve
D Flow Switch VSR-SF

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–10
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Wet System Valves & Devices
RM-1
Riser Manifolds
NFPA 13 - DN40 thru DN150 (1-1/2" thru 6")
Size Range NFPA 13D - DN25 (1")
NFPA 13R - DN40 thru DN50 (1-1/2" thru 2")

UL, C-UL Listed & FM Approved


Approvals
Listed by California State Fire Marshall

Maximum Working
20,7 bar (300 psi)
Pressure

System Commercial (T&D), Residential (ball valve)

End Connection Thread x Thread, Groove x Groove

Tech Data Sheet TFP963

Riser Manifolds may be installed either horizontally or vertically orientation, for both single sprinkler rises and floor control in
high-rises. • Optional Pressure Relief Kits feature a 12,1 bar (175 psi) pressure relief valve and trim components for convenient
integration into commercial and residential riser manifold assemblies.

OUTLET

OPTIONAL
PRESSURE
RELIEF TRIM
CONNECTION
FLOW

B
A

INLET C

G H D
E
F

Model RM-1 Riser Manifolds, Commercial or Residential - TFP963


Ends Dimensions mm Approval & Listings
Part
Type DN A B C D E F G H
No. Inlet Outlet mm mm mm mm mm mm mm mm FM UL
40551 Commercial 40 1-1/2" MPT FPT 254 394 57 143 213 381 111 32 √ √
40601 Commercial 50 2" Groove Groove 330 457 53 143 213 388 111 32 √ √
40611 Commercial 65 2-1/2" Groove Groove 330 460 53 143 213 388 111 32 √ √
40621 Commercial 80 3" Groove Groove 330 460 53 150 219 400 111 32 √ √
40651 Commercial 100 4" Groove Groove 330 514 108 172 273 467 132 50 √ √
40661 Commercial 150 6" Groove Groove 330 514 108 197 300 533 172 50 √ √
40671 Residential 25 1" FPT FPT 254 280 na 96 118 257 100 1" npt √ √
40571 Residential 40 1-1/2" MPT FPT 254 337 na 100 121 290 100 1" npt √ √
40591 Residential 50 2" Groove Groove 330 406 na 105 127 300 100 1" npt √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–11
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Wet System Valves & Devices


RM-2
Riser Manifolds

Size Range DN50 thru DN150 (2" thru 6")

UL, C-UL Listed & FM Approved components


Approvals
Listed by California State Fire Marshall

Maximum Working
20,7 bar (300 psi)
Pressure

System For use in commercial sprinkler systems

DN50 to DN80 (2" to 3") Manifolds: 2.8K


Test Orifice
DN100 to DN150 (4" to 6") Manifolds: 4.2K

End Connection Groove x Groove

Tech Data Sheet TFP964

The TYCO Model RM-2 Riser Manifold features the necessary waterflow alarm, pressure gauge, alarm test orifice, drain, sight glass
and check valve equipment in a single assembly for use in National Fire Protection Association (NFPA) standard NFPA 13 compliant
commercial sprinkler systems. • The riser manifold provides a cost effective and easy transition arrangement to control valves and
system piping. • The riser manifold may be installed in either a horizontal or vertical orientation, for both single sprinkler rises and
floor control in high-rises.

Model RM-2 Riser Manifolds - TFP964


Dimensions mm Approval & Listings
Part
DN C D E F G H
No. B FM UL
mm mm mm mm mm mm
5940601 50 2" 1-1/4" NPT 597 66 239 213 119 130 √ √
5940611 65 2-1/2" 1-1/4" NPT 630 89 254 213 119 145 √ √
5940621 80 3" 1-1/4" NPT 640 94 259 218 119 150 √ √
5940651 100 4" 2" NPT 716 117 282 244 127 168 √ √
5940661 150 6" 2" NPT 795 150 305 290 127 191 √ √

D E TEST AND F G
DRAIN VALVE

SYSTEM
WATER
PRESSURE
GAUGE

B RISER
CHECK VALVE

DRAIN
CONNECTION
(REF.)
1" (25 mm) C
MINIMUM
FLOW

CLEARANCE
H

WATERFLOW
ALARM
SWITCH

SYSTEM
SUPPLY
SHUT-OFF
VALVE

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–12
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Wet System Valves & Devices
TD-2
Test & Drain Valve
DN50 to DN80 (2" to 3") Manifolds: 2.8K
Test Orifice
DN100 to DN150 (4" to 6") Manifolds: 4.2K

UL, C-UL Listed & FM Approved


Approvals
Listed by California State Fire Marshall

Maximum Service
20,7 bar (300 psi)
Pressure

Shut-Off Valve Linear stem actuation with EPDM rubber seals

End Connection Thread x Thread

Tech Data Sheet TFP965

The TYCO Model TD-2 Test and Drain Valve with integral pressure relief provides a simplified means for testing of waterflow alarm
devices and draining of feed mains. • The valve is typically utilized for connection to a common inside drain where it is not practical
to terminate an inspector’s test connection outside of a building. • Linear shut-off eliminates leakage due to debris in media •
Integral pressure relief • Self-cleaning sight glass provides positive indication of flow

Model TD-2 Test & Drain Valve - TFP965


Test Approval & Listings
Part
Size Orifice
No. FM UL
Size
598321 1-1/4" NPT 2.8K √ √
598322 2" NPT 4.2K √ √

ROTATE TEST * DO NOT ROTATE PRESSURE


VALVE HOUSING AS TEST VALVE RELIEF
NECESSARY FOR HOUSING WHEN IN CAP
UNOBSTRUCTED CLOSED POSITION
FULL RANGE
OF HANDLE SET
OPERABILITY * ** TEST VALVE PRESSURE
ORIFICE SIZES: MARKS
1-1/4" VALVE = 2.8K
2" VALVE = 4.2K
SET
ROTATE PRESSURE
HANDLE 180° INDICATING
TEST
TO TEST SURFACE
VALVE ** OPEN DRAIN VALVE
(NORMALLY TEST VALVE FLOW
HOUSING POSITION HANDWHEEL
CLOSED)
(FACTORY
ORIENTATION)

PRESSURE
CLOSED RELIEF
POSITION VALVE

DRAIN VALVE
1-1/4" or 2" NPT (NORMALLY
VALVE AND DRAIN CLOSED) SIGHT GLASS
CONNECTIONS EACH SIDE

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–13
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Wet System Valves & Devices


WMA-1
Water Motor Alarm
NFPA 13D - DN25 (1")
Size Range
NFPA 13R or NFPA 12D - DN50 (2")

Approvals UL, ULC Listed & FM, VdS, CE, & LPCB Approved

Maximum Working
20,7 bar (300 psi)
Pressure

System For use in a wet type automatic sprinkler system riser

TFP921
Tech Data Sheet
TFP922; European Conformity, 16 bar

Hydraulically operated outdoor alarm for use with appropriate fire protection system valves (alarm, dry, deluge) • Supplied by
dedicated outlet in valve trim line or retard chamber • Uses energy-efficient lightweight impeller design capable of producing very
high sound level • Corrosion-resistant aluminium alloy gong, gong-mount, and water motor housing • Furnished with approved 20
mm (3 ⁄4") Y-strainer for use in alarm line

IMPELLER

NOZZLE

INLET
DRAIN

INTERNAL VIEW OF
WATER MOTOR

WMA-1 Water Motor Alarm - TFP921


Approval & Listings
Academy
of Russia

Tech Inlet Outlet Weight


CNBOP

VNIIPO

Part No. Description


T/S/U
LPCB
VdS

Fire
FM

Data NPT NPT kg


EN
UL

CE

526301001P Red WMA-1 + Trim TFP921 3/4” ISO 1” ISO 5 √ √ √ √ √ √ √ √ √ √


526302001P Aluminium WMA-1 + Trim TFP921 3/4” ISO 1” ISO 5 √ √ √ √ √ √ √ √ √ √
526302002 Drain Trim TFP921 - - 2
526301021R Red WMA-1 + Trim TFP922 3/4” ISO 1” ISO 5 √ √ √ √ √ √ √ √ √ √
526302021 Aluminium WMA-1 + Trim TFP922 3/4” ISO 1” ISO 5 √ √ √ √ √ √ √ √ √ √
526302002E Drain Trim TFP922 - - 2

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–14
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry Pipe Sprinkler Systems
Designed for use in dry pipe sprinkler systems where piping and sprinklers are subjected
to freezing temperatures.

- Unheated Warehouses - Attic Spaces

- Parking Garages - Loading Docks

- Store Windows

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–15
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry System Valves & Devices

Air DPV-1 Dry Pipe Valve

BFV-300 Butterfly Valve


to Control Water
Supply to System

Water Supply

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–16
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry System Valves & Devices
DPV-1
Dry Pipe Valve
Size Range DN65 thru DN150 (21 ⁄ 2" thru 6")

Approvals UL, C-UL Listed & FM Approved

Maximum Service
17,2 bar (250 psi)
Pressure

System For use in dry pipe fire protection systems

End Connection Groove x Groove, Flange x Flange, Flange x Groove

Flange Drilling ANSI, ISO, AS, & JIS

Tech Data Sheet TFP1020

External reset differential dry pipe valves • Unique offset single clapper design enabling a simple compact valve to minimise
installation labor • Used to supply sprinkler installations in which sprinklers are subjected to freezing conditions (4˚C / 40˚F or less)
• Ductile iron construction to ensure a lightweight valve to minimise shipping cost. • Compact, Pre-Trimmed, and Semi-Assembled,
easy to operate valve trim. • Simple reset procedure through the elimination of priming water.

H
H H

Model DPV-1 Dry Pipe Valve - TFP1020


H Weight Approval & Listings
Part No. DN Drain Inlet Outlet
mm kg VdS LPCB CE FM UL VNIIPO
523131925 65[76,1mm] 2-1 ⁄ 2” 1-1 ⁄ 2” BSP GRV GRV 311 25 – – – √ √ √
523131930 80 3” 2” BSP GRV GRV 311 25 – – – √ √ √
523131940 100 4” 2” BSP GRV GRV 346 30 √ √ √ √ √ √
523131960 150[168,3mm] 6” 2” BSP GRV GRV 406 55 √ √ √ √ √ √
523131966 150[165,1mm] 6” 2” BSP GRV GRV 406 55 √ √ √ √ √ √
523121040 100 4” 2” NPT ANSI 125 ANSI 125 346 40 √ √ √ √ √ √
523121060 150 6” 2” NPT ANSI 125 ANSI 125 406 60 √ √ √ √ √ √
523131040 100 4” 2” BSP PN10/16 PN10 346 40 √ √ √ √ √ √
523131060 150 6” 2” BSP PN10/16 PN10 406 60 √ √ √ √ √ √
523121440 100 4” 2” NPT ANSI 125 GRV 346 36 √ √ √ √ √ √
523121460 150[168,3mm] 6” 2” NPT ANSI 125 GRV 406 55 √ √ √ √ √ √
523121466 150[165,1mm] 6” 2” NPT ANSI 125 GRV 406 55 √ √ √ √ √ √
523131440 100 4” 2” BSP PN10/16 GRV 346 36 √ √ √ √ √ √
523131460 150[168,3mm] 6” 2” BSP PN10/16 GRV 406 55 √ √ √ √ √ √
523131466 150[165,1mm] 6” 2” BSP PN10/16 GRV 406 55 √ √ √ √ √ √
523131041 100 4” 4” NPT ISO ISO 346 36 √ √ √ √ √ √
523131061 150[168,3mm] 6” 6” NPT ISO ISO 406 60 √ √ √ √ √ √

FM Trims Galvanized - TFP1020 CE/FM Trims Galvanized - TFP1090


Part No. DN Part No. DN
523092005E 65-80 2-1 ⁄ 2” - 3” CE080DPV1 65-80 2-1 ⁄ 2” - 3”
523092001E 100 4” CE100DPV1 100 4”
523092002E 150 6” CE150DPV1 150 6”

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–17
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry System Valves & Devices


Dry System Valve Assemblies DPV-1 with FM Trim DN65-100
Standard Assembly:
Dry Alarm Valve [DPV-1]
Accelerator [ACC-1]
Pressure Alarm Switch [PS10-1]
No Stop Valve*
*For Stop Valve see chapter 3, needs to be ordered separately

G F
B C

E
D
A

DPV-1 FM Dry System Valve Assembly with FM Trim, DN65 - DN100 - TFP1020
Dimensions
Weight
Part No. DN Inlet Outlet A B C D E F G
kg
mm mm mm mm mm mm mm
2B07200101 65[76,1mm] 2-1 ⁄ 2” GRV GRV 305 385 240 595 210 175 210 29
2B37200101 80 3” GRV GRV 305 385 240 595 210 175 210 35
2747200101 100 4” PN10/16 PN10/16 346 300 380 440 625 150 300 58
2847200101 100[114,3mm] 4” PN10/16 GRV 346 300 380 440 625 150 300 54
2B47200101 100[114,3mm] 4” GRV GRV 346 300 380 440 625 150 300 47

B.12
Pos. Description
A Dry Alarm Valve DPV-1
C
B.13 B Alarm Valve Trim, including:
B.1 Main Drain Valve
B.10 B.2 Low Body Drain Valve
B.3 Alarm Test Valve
B.9 B.11 B.4 Gauge Test Valve
B.6 B.5 Water Supply Pressure Gauge
B.8
B.6 Check Valve
B.7 Automatic Drain Valve
B.8 System Air Pressure Gauge
B.4
B.9 Pressure Relief Valve
B.7
D B.10 Strainer
B.11 Air Supply Control Valve
B.12 Accelerator Pressure Gauge
B.13 Accelerator Control Valve
C Accelerator ACC-1
D Pressure Alarm Switch PS10-1
B.1

B
B.2

B.5
B.3

B.4

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–18
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry System Valves & Devices
Dry System Valve Assemblies DPV-1 with FM Trim DN150
Standard Assembly:
Dry Alarm Valve [DPV-1]
Accelerator [ACC-1]
Pressure Alarm Switch [PS10-1]
No Stop Valve*
*For Stop Valve see chapter 3, needs to be ordered separately

G F B C

E
D
A

DPV-1 FM Dry System Valve Assembly with FM Trim, DN150 - TFP1020


Dimensions
Weight
Part No. DN Inlet Outlet A B C D E F G
kg
mm mm mm mm mm mm mm
2767200101 150 6” PN10/16 PN10/16 406 380 375 475 600 190 290 78
2867200101 150 [168,3mm] 6” PN10/16 GRV 406 380 375 475 600 190 290 73
2B67200101 150 [168,3mm] 6” GRV GRV 406 380 375 475 600 190 290 78
Other options available on request

B.13
Pos. Description
A Dry Alarm Valve DPV-1
B Alarm Valve Trim, including:
B.1 Main Drain Valve
B.12
D B.2 Low Body Drain Valve
B.10 Alarm Test Shut Off Valve
B.11 B.3 3-way [supervised]
C B.9 B.4 Gauge Test Valve
B.6
B.6 B.5 Water Supply Pressure Gauge
B.8 B.3
B.6 Check Valve
B.5
B.7 Automatic Drain Valve
B.4 B.8 System Air Pressure Gauge
B.9 Manifold
B.2
B.10 Air Supply Control Valve
B B.4
B.7 B.11 Accelerator Pressure Gauge
Accelerator Control Valve
B.12
[supervised]
C Accelerator ACC-1
A
B.1 D Pressure Alarm Switch PS10-1
E Supervised Gate Valve [05-47]

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–19
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry System Valves & Devices


Dry System Valve Assemblies DPV-1 with CE/VdS Trim DN100
Standard Assembly:
Dry Alarm Valve [DPV-1]
Accelerator [ACC-1]
Pressure Alarm Switch [PS10-1]
Gate Valve [0547] Supervised

G E

D
F

A B

DPV-1 Dry System Valve Assembly with CE/VdS Trim, DN100 - TFP1090
Dimensions mm Approval & Listings

Belarusian
Ukrainian

Academy
of Russia
Weight
Part No. DN Inlet Outlet

LPCB

VKF
VdS

Fire
kg

EN
A B C D E F G

CE
2748861105 100 4” PN10/16 PN10/16 412 400 193 346 820 438 243 85 √ √ √ √ √ √ √ √
2848861105 100 [114,3mm] 4” PN10/16 GRV 412 400 193 346 820 438 243 81 √ √ √ √ √ √ √ √
Other options available on request
B.11

C Pos. Description
A Dry Alarm Valve DPV-1
B Alarm Valve Trim, including:
B.1 Main Drain Valve
B.2 Low Body Drain Valve
Alarm Test Shut Off Valve 3-way
B.3
B.12 [supervised]
B.5 B.4 Gauge Test Valve
B.5 Water Supply Pressure Gauge
B.6 Check Valve
B.4
B.7 Automatic Drain Valve
A B.8 System Air Pressure Gauge
B.8
B.4 B.9 Manifold
B.10
B.10 Air Supply Control Valve
B.6
B B.11 Accelerator Pressure Gauge
Accelerator Control Valve
B.12
[supervised]
B.9
B.1 C Accelerator ACC-1
D D Pressure Alarm Switch PS10-1
B.2 E Supervised Gate Valve [05-47]

B.3
B.7

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–20
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry System Valves & Devices
Dry System Valve Assemblies DPV-1 with CE/VdS Trim DN150
Standard Assembly:
Dry Alarm Valve [DPV-1]
Accelerator [ACC-1]
Pressure Alarm Switch [PS10-1]
Gate Valve [0547] Supervised

F
D

A C
DPV-1 Dry System Valve Assembly with CE/VdS Trim, DN150 - TFP1090
Dimensions mm Approval & Listings

Belarusian
Ukrainian

Academy
of Russia
Weight
Part No. DN Inlet Outlet

LPCB

VKF
VdS

Fire
kg

EN
A B C D E F G

CE
2768861105 150 6” PN10/16 PN10/16 407 414 213 406 875 583 243 122 √ √ √ √ √ √ √ √
2868861105 150 [168,3mm] 6” PN10/16 GRV 407 414 213 406 875 583 243 117 √ √ √ √ √ √ √ √
2B68800101 150 [168,3mm] 6” GRV GRV 407 414 153 406 875 190 243 77 √ √ √ √ √ √ √ √
Other options available on request

B.11
Pos. Description
C
A Dry Alarm Valve DPV-1
B Alarm Valve Trim, including:
B.1 Main Drain Valve
D B.2 Low Body Drain Valve
Alarm Test Shut Off Valve 3-way
B.3
[supervised]
B.4 Gauge Test Valve
B.12 B.3 B.5 Water Supply Pressure Gauge
A
B.6 Check Valve
B.7 Automatic Drain Valve
B
B.8 System Air Pressure Gauge
B.7 B.9 Manifold
B.10 B.10 Air Supply Control Valve
B.6 B.11 Accelerator Pressure Gauge
B.2
B.12 Accelerator Control Valve [supervised]
C Accelerator ACC-1
B.9 B.5
D Pressure Alarm Switch PS10-1
B.4 E Supervised Gate Valve [05-47]

B.1

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–21
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry System Valves & Devices


Dry System Valve Assemblies DPV-1 with CE/FM Trim DN65-100
Standard Assembly:
Dry Alarm Valve [DPV-1]
Accelerator [ACC-1]
Pressure Alarm Switch [PS10-1]
No stop Valve*
*For Stop Valve see chapter 3, needs to be ordered separately

F
E

C
A B

DPV-1 Dry System Valve Assembly with CE/FM Trim, DN65-100 - TFP1090
Dimensions mm Approval & Listings

Belarusian
Ukrainian
Weight
Part No. DN Inlet Outlet

LPCB
FM
A B C D E F G kg

CE
2B08900101* 65 [76,1mm] 2-1/2” GRV GRV 395 263 116 311 775 124 193 33 √ √ √ √
2B38900101* 80 3” GRV GRV 395 263 116 311 775 124 193 39 √ √ √ √
2748900101 100 4” GRV GRV 407 376 137 349 787 150 193 51 √ √ √ √ √
2848900101 100 4” PN10/16 PN10/16 407 376 137 349 787 150 193 51 √ √ √ √ √
2B48900101 100 4” PN10/16 GRV 407 376 137 349 787 150 193 51 √ √ √ √ √
* No CE
Other options available on request

B.11
Pos. Description
A Dry Alarm Valve DPV-1
C B Alarm Valve Trim, including:
B.1 Main Drain Valve
B.2 Low Body Drain Valve
B.5 Alarm Test Shut Off Valve 3-way
B.3
[supervised]
B.4 Gauge Test Valve
B.4 B.5 Water Supply Pressure Gauge
B.8
B.6 Check Valve
B.7 Automatic Drain Valve
A B.8 System Air Pressure Gauge
B.9 Manifold
B.10 B.6 B.10 Air Supply Control Valve
B
B.11 Accelerator Pressure Gauge
B.12 Accelerator Control Valve [supervised]
B.12 C Accelerator ACC-1
B.2
D Pressure Alarm Switch PS10-1
B.1

B.9
B.3
D

B.7

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–22
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry System Valves & Devices
Dry System Valve Assemblies DPV-1 with CE/FM Trim DN150
Standard Assembly:
Dry Alarm Valve [DPV-1]
Accelerator [ACC-1]
Pressure Alarm Switch [PS10-1]
No stop Valve*
*For Stop Valve see chapter 3, needs to be ordered separately

F
E

A B
DPV-1 Dry System Valve Assembly with CE/FM Trim, DN150 - TFP1090
Dimensions mm Approval & Listings

Belarusian
Ukrainian
Weight
Part No. DN Inlet Outlet

LPCB
FM
A B C D E F G kg

CE
2B68900101 150 [168,3mm] 6” GRV GRV 339 375 135 406 415 184 193 73 √ √ √ √ √
2768900101 150 6” PN10/16 PN10/16 339 375 135 406 415 184 193 68 √ √ √ √ √
2868900101 150 [168,3mm] 6” PN10/16 GRV 339 375 135 406 415 184 193 77 √ √ √ √ √
Other options available on request

B.11
Pos. Description
A Dry Alarm Valve DPV-1
C D B Alarm Valve Trim, including:
B.1 Main Drain Valve
B.2 Low Body Drain Valve
B.3 Alarm Test Shut Off Valve 3-way [supervised]
B.4 Gauge Test Valve
A
B.5 Water Supply Pressure Gauge
B.7 B.6 Check Valve
B.6
B.10 B.12
B.3
B.7 Automatic Drain Valve
B.8 B.2
B B.8 System Air Pressure Gauge
B.9 Manifold
B.10 Air Supply Control Valve
B.5 B.11 Accelerator Pressure Gauge
B.9 B.12 Accelerator Control Valve [supervised]
B.4
C Accelerator ACC-1
D Pressure Alarm Switch PS10-1

B.1

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–23
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry System Valves & Devices


Alternate Valve Assemblies, Model LPC Trim
Standard Assembly:
Dry Alarm Valve [DPV-1], TFP1090 D
Wet Alarm Valve [AV-1], TFP910
Gate Valve [0557]
Pressure Alarm Switch [PS10-1]
Accelerator [ACC-1], TFP1112

C.4

Pos. Description
A Dry Pipe Valve DPV-1
B Wet Alarm Valve AV-1 A
C.9 C.2
C Alarm Valve Trim, including:
C.1 Test & Drain Valve
C.2 Gauge Test Valve C.3
C.3 Air Supply Control Valve
C.4 Accelerator Control Valve
C.5 Automatic Drain Valve
C.6 Check Valve
C.7 Alarm Shut-Off Valve
E
C.8 Supply Pressure Gauge
C.9 System Pressure Gauge
D Accelerator ACC-1 C.7
E Pressure Switch PS10-1
F Superused Gate Valve 05-57 C.8

C.2
B
C.5 C

C.6
B
C.1

F
H G
D C
I E

Alternate Valve Assembly, LPC Trim


Dimensions mm
Part No. DN Inlet Outlet
A B C D E F G H I
6348919101 100 4” PN10/16 PN10/16 841 455 255 206 363 111 438 190 266
6368919101 150 6” PN10/16 PN10/16 990 419 281 234 399 152 583 190 282

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–24
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry System Valves & Devices
ACC-1
Dry Pipe Valve Accelerator
Approvals UL, C-UL Listed & FM, LPCB, & VdS Approved

Maximum Working
4,8 bar (70 psi)
Air Pressure

System For use in dry pipe fire protection systems

End Connection Threaded

Tech Data Sheet TFP1112

Model ACC-1 Accelerator reduces the time for valve operation following the operation of one or more automatic sprinklers. •
Automatically adjusts to small or slow changes in system pressure but trips upon a rapid and steady drop in pressure • Designed to
trip when system air pressure drops at a rate exceeding approximately 0.07 bar/minute (1 psi/minute) • Upon tripping, it transmits
system air pressure to the intermediate chamber of the dry pipe valve, which neutralizes the differential pressure holding the valve
closed and opens the waterway clapper • Rated for use at a maximum water supply pressure of 17,2 bar (250 psi) and a maximum
system air (or nitrogen) pressure of 4,8 bar (70 psi)

Model ACC-1 Dry Pipe Accelerator


Approval & Listings
Fire
Part No. Description
VdS LPCB FM UL VKF TSU Academy of
Russia
523111001 Accelerator ACC-1 √* √ √ √ √ √ √
523112010E Trim √* √ √ √ √ √ √

523111001

Vent Plug

Reset Knob

523112010E

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–25
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry System Valves & Devices


QRS
Electronic Accelerator
Approvals UL Listed & FM Approved

Maximum Working
4,8 bar (70 psi)
Air Pressure

System For use in dry pipe fire protection systems

End Connection Threaded

Tech Data Sheet TFP1100

Quick opening device intended to reduce the time for dry pipe valve operation following the operation of one or more automatic
sprinklers. • Automatically adjusts to both small and slow changes in system pressure, but trips with a steady drop in pressure (as
in the case of sprinkler operation) • Can be used to retro-fit existing mechanical accelerators • Fully assembled package includes
switch, solenoid, control panel, and accelerator trim pipe and fittings • Built-in low and high pressure alarm supervision • Proven
electronic release technology as used for electrically operated deluge and preaction systems • Battery back-up in the event of
primary power failure • Eliminates re-setting problems often incurred with traditional mechanical accelerators

MODEL QRS QUICK


RELEASE SWITCH
P/N 92-312-1-001

4 INCH (DN100)
MODEL DPV-1
DRY PIPE VALVE
WITH TRIM
SHOWN

120 VAC

MODEL QRS
ELECTRONIC
ACCELERATOR TRIM
P/N 52-312-2-001
MODEL PFC-4410-RC
RELEASING PANEL,
P/N 20135, WITH:
MODEL BT-120
BATTERY BACK-UP,
P/N 20128;
OR MODEL BT-180,
BATTERY BACK-UP,
24 VDC P/N 20121
SOLENOID VALVE
(NORMALLY CLOSED
UNTIL ENERGIZED)
P/N 52-287-1-024

Model QRS Electronic Accelerator


Approval & Listings
Part No. Description
FM UL
923121001 Quick Release Switch √ √
522871024P Solenoid Valve √ √
523122001 Trim √ √
923121002 PFC-100RC Releasing Panel √ √
923121003 BT-40 4,0 AH Battery [2 x req.] √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–26
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry System Valves & Devices
AMD-1
Air Maintenance Device, Pressure Reducing Type
UL, C-UL Listed & FM Approved &
Approvals
NYC Approved under MEA 206-02-E

Field-Adjustable
0,4 to 4,8 bar (5 to 70 psi)
Outlet Pressure Range

Maximum Inlet Air


13,8 bar (200 psi)
Supply Pressure

System For use in dry pipe fire protection systems

Tech Data Sheet TFP1221

Field adjustable • Used in systems where compressed air source is available • Used in systems in which the air supply is at a higher
pressure than is desired for a sprinkler system or dry pilot line system

409,6 mm
50,8 mm
(16-1/8")
(2")
BY-PASS VALVE
1/4" NPT
(NORMALLY
GAUGE
CLOSED)
TEST PORT
82,6 mm 1/2" NPT P/N 46-047-1-004
(3-1/4") OUTLET
CONNECTION
(TO SYSTEM)
215,9 mm
(8-1/2") 1/2" NPT
LABEL INLET CONNECTION
(FROM COMPRESSED
AIR SUPPLY)

RESTRICTOR
CHECK VALVE
P/N 92-326-1-003
PRESSURE AIR SUPPLY
REGULATOR STRAINER CONTROL VALVE
(ADJUSTABLE) P/N 52-353-1-002 (NORMALLY OPEN)
P/N 92-324-1-012 P/N 46-048-1-002

Model AMD-1 Air Maintenance Device, Pressure Reducing Type


Approval & Listings
Part No. Description
FM UL
523242002E Pressure Reducing Type √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–27
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry System Valves & Devices


AMD-2
Air Maintenance Device, Compressor Control Type
UL, C-UL Listed & FM Approved &
Approvals
NYC Approved under MEA 206-02-E

Field-Adjustable Minimum Cut-In (On) 1,0 bar (14 psi)


Pressures Maximum Cut-Out (Off) 4,1 bar (60 psi)

The housing of the Pressure Switch meets


NEMA Rating
NEMA 1 requirements.

System For use in dry pipe fire protection systems

Tech Data Sheet TFP1231

Field adjustable • Used in conjunction with a small, non-tank-mounted air compressor • Monitors sprinkler system or dry pilot line
detection for deluge system air pressure and automatically cycles the compressor to maintain system pressure within preset limits

PRESSURE SWITCH BY-PASS VALVE


1/2" CONDUIT (WITH UNLOADER VALVE) (NORMALLY CLOSED)
OPENINGS P/N 92-326-1-001 P/N 46-047-1-004

1/2" NPT INLET


CONNECTION
1/2" NPT OUTLET (FROM AIR
CONNECTION COMPRESSOR) 177,5 mm
(TO SYSTEM) (7")

317,5 mm
(12-1/2")

63,5 mm
(2-1/2")

RESTRICTOR
CHECK VALVE STRAINER
P/N 92-326-1-003 P/N 52-353-1-002
101,6 mm 419,1 mm
(4") (16-1/2")

Model AMD-2 Air Maintenance Device, Compressor Control Type


Approval & Listings
Part No. Description
FM UL
523262001 Compressor [w/o Tank] Control Type √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–28
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Dry System Valves & Devices
AMD-3
Nitrogen Maintenance Device, High Pressure (Cylinder) Reducing Type
UL, C-UL Listed & FM Approved &
Approvals
NYC Approved under MEA 206-02-E

Field-Adjustable
Outlet Pressures 0,4 to 4,1 bar (4 to 60 psi)
Range

Maximum Inlet
Nitrogen Supply 200 bar (3000 psi)
Pressure

System For use in dry pipe fire protection systems

Tech Data Sheet TFP1241

Field adjustable • Used in conjunction with a cylinder of high pressure nitrogen to control the nitrogen pressure in a sprinkler
system or a dry pilot line detection for deluge systems

INLET (HIGH
PRESSURE)
GAUGE
m
OUTLET (LOW
4 1 ,4 m")
PRESSURE) 2 -1/2
GAUGE (9

CYLINDER
CONTROL
VALVE
(NORMALLY
OPEN)

RESTRICTOR
C.G.A.
CHECK VALVE
CONNECTION
P/N 92-326-1-003
NO. 580

m
,5 m ) TWO-STAGE
317-1/2" PRESSURE
(12 REGULATOR CYLINDER OF
BY-PASS (ADJUSTABLE) 3000 PSI MAX.
VALVE P/N 92-290-1-001 NITROGEN
(NORMALLY
CLOSED)
1/4" TUBE,
P/N 46-047-1-002
5 FEET LONG
1/4" MALE NPT
x 1/4" TUBE
CONNECTOR
(156-1/4 1/2" NPT OUTLET
8,8 "
mm CONNECTION
) (TO SYSTEM)

Model AMD-3 Nitrogen Maintenance Device, High Pressure (Cylinder) Reducing Type
Approval & Listings
Part No. Description
FM UL
523282001 Model AMD-3 Automatic Nitrogen Maintenance Device √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–29
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Dry System Valves & Devices


LE020
Air Feeding Devices

Approvals VdS

Maximum Inlet
Nitrogen Supply Maximum inlet pressure 3,5 bar
Pressure

System For use in dry pipe fire protection systems

Tech Data Sheet Contact Tyco for details

For feeding air into a dry pipe valve system

Out 6

5 4
2

LE020 Air Feeding Devices


Part No. NR. Description VdS
In
1 Inlet: Hose Connection 3/8” √
2 Ball Valve 1/2” √
3 Pressure Gauge 0-16 Bar 1/2” √
LE020TGR 4 Safety Valve @ 3,5 Bar 3/4” √
5 Ball Valve 3/4” √
6 Outlet: 3/4” Male/Female Union √
Pressure Reducing Type √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–30
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Compressors
Model G16AC812
Automatic Supervisory Air Supply

Approvals UL Listed & CSA Certified

Nominal Supervisory
0,7 bar (10 psi)
Air Pressure

Tech Data Sheet TFP1620

Supplies and maintains air in single interlock preaction fire protection systems • Can be mounted on the floor, on a wall, or to the
system riser using optional brackets

1/2" CONDUIT 133mm 73mm


CONNECTION 143mm

108mm 3

1
4

70mm

330mm
5

8 x 25mm 2
(4 Slotted Holes)
159mm 6

1/4" NPT OUTLET

203mm 206mm

Model G16AC812 Automatic Supervisory Air Supply Model G16AC812 Components


Approval & Listings NR. Description
Part No. Description
UL CSA 1 Motor
Model G16AC812 Automatic Supervisory Air 2 Pump
521501001 √ √
Supply 3 Pressure Operated Switch
521501000 Universal Riser Mounting Kit 4 Inlet Air Filter
5 Sensing Line
6 Check Valve
7 Relief Valve

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–31
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Compressors
Model AB
Compressors

CE:
Approvals 98/37/CEE • 89/336/CEE • 73/23/CEE • 93/68/CEE •
EN60204/1 • EN1012/1 • EN60335/1 • 87/404/CEE

Tech Data Sheet Contact Tyco for details

The AB compressor is for use in dry, deluge and pre-action fire protection systems. • The compressor unit is an air-cooled double
cylinder compressor pump, belt driven by an electric motor. • The AB is supplied complete with a tank, pressure control switch with
on/off manual override, off loading valve, automatic thermal overload switch, tank pressure gauge, pressure reducer assembly and
pressure gauge, condensate drain valve and safety valve. • The unit should be supported on the ground by means of four anti-
vibration mountings and anchors.

1000

1460 610

Model AB Compressors
Nominal Power Effec. Air Ambient Thermal Compressor Weight
Frequency Noise Level
Kw Delivery Temp. Range Protection Connection kg
327 ltr./min. at
3 [in]/2,3 [out] +5/+40° C 50 Hz Automatic Reset 80 dB [A] Rapid tap 110
2,8 Bar

Model AB Compressors
Air Rotation Degree of Volume Air Outlet Press. Oil Content
Voltage Nom. Current
Displacement Speed Protection Tank red. assy Assy
Three Phase
397 ltr./min. 1210 rpm. 7,5 A IP54 200 ltr. 3/8” Female BSP 0,64 ltr.
400 VAC

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–32
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Compressors
Model CCS
Compressors

TUV: Cert. AL990635692001

Approvals CE:
98/37/CEE • 89/336/CEE - 73/23/CEE • 93/68/CEE •
EN60204/1 • EN1012/1 • EN60335/1 • 87/404/CEE

Tech Data Sheet Contact Tyco for details

The CCS compressor is for use in a dry, deluge and pre-action fire protection systems. • The compressor unit is an air-cooled double
cylinder compressor pump, belt driven by an electric motor. • The CCS is supplied complete with a tank, pressure control switch
with on/off manual override, off loading valve, automatic thermal overload switch, tank pressure gauge, pressure reducer assembly
and pressure gauge, condensate drain valve and safety valve. • The unit is supported on the ground by two wheels and one anti-
vibration mounting

660 (25 ltr)


690 (50 ltr)

740 (25 ltr) 320 (25 ltr)


1010 (50 ltr) 360 (50 ltr)

Model CCS Compressors


Nominal Power Ambient Temp. Compressor Weight
Effec. Air Delivery Frequency Thermal Protection Noise Level
Kw Range Connection kg
187 ltr./min. at 2,8
2,0 [in]/1,5 [out] +5/+40° C 50 Hz Automatic reset 77 dB [A] Rapid tap 53
Bar

Model CCS Compressors


Air Rotation Nom. Degree of Volume Air Outlet Press. Oil Content
Voltage
Displacement Speed Current Protection Tank Red. Assy Assy
Single Phase
248 ltr./min. 1240 rpm. 7,5 A IP42 25 / 50 ltr. 3/8” female BSP 0,32 ltr.
230 VAC

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–33
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Deluge & Preaction Systems
For use in deluge and preaction fire sprinkler systems.

- Aircraft Hangars - High-Hazard Installations Using


Water as Extinguishing Agent
- Refrigerated Areas
- Archives
- Flammable Liquid Handling
- Libraries

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–35
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Deluge & Preaction Systems


DV-5A

Deluge Valve, External Resetting Diaphragm Style – 11/2" thru 8"

The TYCO DV-5A Automatic Water Control Valves are


diaphragm type valves that can be used in deluge fire
protection systems. When properly trimmed, the double
seat design of the DV-5A Valve also provides actuation of
fire alarms upon system operation.

The diaphragm style design of the DV-5A Valve allows


external resetting, providing for easy resetting of a
deluge system without having to open a valve handhole
cover to manually reposition a clapper and/or latch
mechanism. Simply re-pressurizing the diaphragm
chamber resets the valve.

The DV-5A features internal and external coating of


the valve to provide corrosion resistance. The external
corrosion resistance of the epoxy coating permits the
use of the DV-5A in corrosive atmospheres associated
with many types of industrial processing plants and
outdoor installations.

Size Range DN40 thru DN200 (11 ⁄ 2" thru 8")

Approvals UL, C-UL Listed & FM, VdS & LPCB Approved

Maximum Service
1,4 bar (20 psi) to 20,7 bar (300 psi)
Pressure

Deluge Systems:
- Wet Pilot Actuation - TFP1306
- Dry Pilot Actuation - TFP1306
- Electric Actuation - TFP1306
- Remote Reset - TFP1325
- Remote Reset Pressure Reducing - TFP1326
Single Interlock Preaction Systems:
Types of System
- Wet Pilot Actuation - TFP1425
- Dry Pilot Actuation - TFP1425
- Electric Actuation - TFP1425
Double Interlock Preaction Systems:
- Electric/Pneumatic Actuation - TFP1450
- Electric/Electric Actuation - TFP1450
- Preaction Type A - TFP1485

Thread x Thread, Groove x Groove,


End Connection
Flange x Flange, Flange x Groove

Flange Drilling ANSI, ISO, AS, & JIS

TFP1306, TFP1325, TFP1326,


Tech Data Sheet
TFP1425, TFP1450, TFP1485

Vertical installation • One internal working part, Diaphragm operation • No linkage or clapper assembly • Light weight ductile
iron body • Available with deluge and single & double interlock preaction trim • Internally & externally coated • Features external
resetting • For deluge, preaction & foam systems

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–36
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
DN50 (2")

349 mm
Deluge & Preaction Systems
(13-3/4")

Dimensions Shown
DV-5A Deluge Valve
Are Applicable To
DN80 (3")
All End Connection
Configurations
Available Per
Valve Size

425 mm
10-3/16" (16-3/4")
(260 mm)

DN40 (1-1/2") DN100 (4")

260 mm
(10-3/16") 569 mm
(22-3/8")

DN50 (2")
DN150 (6")

349 mm
(13-3/4")
697 mm
(27-7/16")

DN80 (3")
DN200 (8")

DV-5A Deluge Valve - Part No. System Size Approval & Listings
T x T NPT T x T ISO G x G 425F mm
x F ANSI F x F ISO F x G ANSI F x G ISO DN In UL FM VdS LPCB
(16-3/4")
530060015 530070015 530010015 – – – – 40 1-1/2" √ √ √ √
530060020 530070020 530010020 – – – – 50 2" √ √ √ √
– – 530010030 530020030 530040030 530030030 530050030 80 3" √ √ √ √
– – DN100
530010040 (4")
530020040 530040040 530030040 530050040 100 4" √ √ √ √
– – 530010060 530020060 530040060 530030060 530050060 150 6" √ √ √ √
– – 530010080 530020080 530040080 530030080 530050080 200 8" √ √ √ √

569 mm
(22-3/8")

DV-5A Parts List


NR. Description DN150 (6") 1

1 Valve Body 1
3
2 Diaphragm 2
3 Diaphragm Cover 7 5
5 3
4 Hex Bolt, Short 1-1/2 AND 2 INCH
9 VALVES ONLY
5 Hex Bolt, Long 697 mm 6
6 Lift Washer (27-7/16")
3
7 Hex Nut 7 1
8 Hoist Ring
4
9 Flat Washer 8
DN200 (8")
6
4
9 7 5
6 AND 8 INCH
1 2
VALVES ONLY

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–37
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Deluge & Preaction Systems


DP-1

Dry Pilot Actuator


Approvals UL, C-UL Listed & FM, LPCB Approved
Maximum Water
17,2 bar (250 psi)
Supply Pressure
Maximum System Air
3,4 bar (50 psi)
(Nitrogen) Pressure
Tech Data Sheet TFP1380

Dry Pilot Actuator is an auxiliary releasing device • When the Model DP-1 actuates, it permits water pressure to be released from
the deluge or preaction valve differential chamber, thereby allowing the deluge or preaction valve to open • Designed for Preaction
Valves having double interlock electric/pneumatic release

130,2 mm
(5-1/8") DIA.

54,0 mm
(2-1/8")
85,7 mm
(3-3/8")

31,8 mm
(1-1/4")

42,9 mm
(1-11/16")

Model DP-1 Dry Pilot Actuator


Weight Approval Listings
Part No. Pilot Inlet Outlet
kg LPCB FM UL
522801001 1/2” NPT 1/2” NPT 1/2” NPT 3 √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–38
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Deluge & Preaction Systems
Solenoid Valve

For Releasing Service

Sizes DN15 (1 ⁄ 2")

Approvals UL, VdS, CSA, LPC, FM Approved & CE Certified

Working Pressure 1,4 - 20,7 bar (20 - 300psi)

Tech Data Sheet TFP2180

Used in conjunction with an electric releasing panel that is listed or approved (as appropriate) for fire protection releasing service,
and where the releasing panel is operated by listed or approved (as appropriate) electric fire detectors • Available in a variety of
voltages for both normal and hazardous locations

Figure 1 Figure 3

1/2" CONDUIT
1/2" CONDUIT CONNECTION
CONNECTION
96,8 mm 136,5 mm
(3-13/16") (5-3/8")
ELECTRICAL 111,1 mm
LEADS (4-3/8") 152,4 mm
(6")
1/2" NPT
66,7 mm (TYPICAL)
65,1 mm 1/2" NPT
(2-5/8") (2-9/16") (TYPICAL)
65,1 mm 41,3 mm
(2-9/16") (1-5/8")

Figure 2 Figure 4

1/2" CONDUIT
CONNECTION ELECTRICAL
98,4 mm CONNECTION
(3-7/8") 89,6 mm
(3-1/2")
ELECTRICAL 117,5 mm
LEADS 104,8 mm
(4-5/8") (4-1/8")

1/2" NPT 1/2" NPT


(TYPICAL) (TYPICAL)
69,9 mm 50,8 mm 75,0 mm 53,0 mm
(2-3/4") (2") (2-15/16") (2-1/8")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–39
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Deluge & Preaction Systems


Solenoid Valve

√ Valve
Model FSV-1 Fail-Safe
Working AC Volt-Amps Approval Listings
Enclosure
See Water DC
Part No. Type Voltage Watts
Fig. Pressure Inrusha Holdingb Amp UL1 UL 3 FM3 VdS3 LPC 3 CSA1 CE2
(NEMA Rtings)
bar
For Use With DV-5A Deluge and Preaction System Trim
120 VAC, 60 Hz
522871110 1 1,4-12,1 10 31 16 – √ √
110 VAC, 50 Hz
522871024 1 1,4-12,1 24 VDC 10 – – 0,41 √ √ √ √
522871124 Ordinary Location 2 1,4-20,7 24 VDC 22 – – 0,83 √ √ √ √ √ √
(2, 4, and 4X)
522871048 1 1,4-12,1 48 VDC 10 – – 0,21 √ √
522871125 1 1,4-12,1 125 VDC 11 – – 0,08 √ √
522871015 1 1,4-12,1 250 VDC 10 – – 0,04 √ √
522871210 Hazardous Location 1 1,4-12,1 110/120 VAC 10 31 16 – √ √
522871224 (4, 4X, 7, and 9) 1 1,4-12,1 24 VDC 10 – – 0,41 √ √
For Use With DV-5A Remote Resetting System Trim
2460566 Ordinary Location 3 1,4-16,0 24 VDC 11 – – 0,46 √ √
For Use With DV-5A Preaction Type A System Trim
Ordinary Location
522871124 2 1,4-20,7 24 VDC 22 – – 0,83 √ √ √
(2, 4, and 4X)
2191866 Ordinary Location 4 1,4-15,0 24 VDC 8 – – 0,33 √
1. UL Listed and CSA Certified under the name of Parker Hannifin Corporation, Skinner Valve Division.
2. CE conformance under the name of Parker Lucifer SA.
3. Approved as a trim component for release of the Model DV-5A or DV-5 Automatic Water Control Valves.
a. Current to start plunger moving
b. Current to hold plunger open

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–40
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Deluge & Preaction Systems
MC-1

Manual Control Station

Approvals UL, C-UL Listed & FM Approved

Working Water
1,4 to 20,7 bar (20 to 300 psi)
Pressure

Minimum Ambient Dry Pilot Lines: -46°C (-50°F)


Temperature Wet Pilot Lines: 4°C (40°F)

Tech Data Sheet TFP1382

Provides a tamper resistant means for emergency release • Interconnection with the valves may be direct via hydraulic (wet) pilot
line or indirect via pneumatic (dry) pilot line to a Model DP-1 Dry Pilot Actuator

90,5 mm 73,0 mm
(3-9/16") (2-7/8") 1/2" NPT
INLET
38,4 mm
(1-1/2")

BREAK
188,7 mm ROD
(7-7/16")

104,8 mm
(4-1/8")

1/2" NPT
OUTLET
COVER (DRAIN)
(OPEN)
38,4 mm 52,4 mm 123,8 mm 30,2 mm
(1-1/2") (2-1/16") (4-7/8") (1-3/16")

Model MC-1 (MC-2) Manual Control Station


Approval & Listings
Part No. Model Use With
FM UL
522892001 MC-1 √ √
545002000 MC-2 DV-5A √ √
922891008 Replacement Break Rod

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–41
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Deluge & Preaction Systems

AD-1
Automatic Drain Valve
The Model AD-1 Automatic Drain Valve forms a
part of the overall approvals given in the applicable
Approvals
technical data sheets for the TYCO Dry Pipe, Deluge,
or Preaction Valves.

Maximum Working
17,2 bar (250 psi)
Pressure

Tech Data Sheet TFP1630

Designed for use with Tyco Dry Pipe, Deluge, and Preaction Valves • Provided as a trim component for these valves, the Model
AD-1 Automatic Drain Valve is used to automatically drain the normally dry alarm lines

BODY BALL RETAINER


(OPEN
INLET POSITION) BALL
(CLOSED SPRING
1/2" POSITION)
NPT PLUNGER

77,8 mm
OUTLET
(3-1/16")
120,7 mm
(4-3/4”)

Model AD-1 Automatic Drain Valve


Part No.
Figure No.
Black Steel Inlet Galvanised Steel Inlet Brass Inlet
AD-1 52-793-1-004 52-793-2-004 52-793-3-004

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–42
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Deluge & Preaction Systems
AD-2
Automatic Drain Valve
Approvals UL Listed & FM Approved

Maximum Working
12,1 bar (175 psi)
Pressure

Tech Data Sheet TFP1632

Designed to automatically drain water from fire protection equipment supply connections that are to be maintained normally dry •
Installed vertically and utilised with an open drain

INLET

1/2" NPT

11 mm
(7/16") WRENCH HEX
NOMINAL 27 mm (1-1/16")
MAKE-IN ACROSS FLATS

BODY
83 mm
(3-1/4")
BALL

SPRING

BLEED
ORIFICE
(TWO)

OUTLET
OPEN CLOSED

Model AD-2 Automatic Drain Valve


Approval & Listings
Figure No. Part No.
UL FM
AD-2 52-789-1-004 √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–43
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Deluge & Preaction Systems


Deluge Systems

Wet Pilot, Dry Pilot, Electric Actuation, Remote Resetting or


Remote Resetting Pressure Reducing

Deluge fire protection systems are normally used


in special hazard installations where an entire
area application of water or foam is required for
protection. Applications may include flammable
liquid handling and storage areas, aircraft hangars,
and other high-hazard installations where water
is the most effective extinguishing agent. Deluge
systems employ open sprinklers or spray nozzles
attached to a piping system. The system is
connected to a water supply through the deluge
valve. This valve is opened by the operation of a
fire detection system installed in the same areas
as the open sprinklers or nozzles. Deluge systems
may be activated by wet or dry pilot sprinklers, or
electric detectors. When the deluge valve opens,
water flows into the piping system and discharges
from all open sprinklers and nozzles.

(Electric Actuation Trim Shown)

DV-5A Size Range DN40 thru DN200 (11 ⁄ 2" thru 8")

Approvals UL, C-UL Listed & FM, VdS & LPCB Approved

Wet Pilot Actuation: 20,7 bar (300 psi)


Maximum Service
Dry Pilot Actuation: 17,2 bar (250 psi)
Pressure
Electric Actuation: Per Solenoid, see TFP2180

Thread x Thread, Groove x Groove,


End Connection
Flange x Flange, Flange x Groove

Flange Drilling ANSI, ISO, AS, & JIS


(Remote
Resetting TFP1306 - DV-5A Wet, Dry & Electric
Trim Shown) Tech Data Sheet TFP1325 - DV-5A Remote Resetting
TFP1326 - DV-5A Remote Resetting, Pressure Reducing

Vertical installation • One internal working part, Diaphragm operation • No linkage or clapper assembly • Light weight ductile
iron body • Available with deluge and single & double interlock preaction trim • Internally & externally coated • Features external
resetting • For deluge, preaction & foam systems

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–44
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Deluge & Preaction Systems

DV-5A Deluge Systems, Wet Pilot


J B C D
A

G E

H F

Part Number do not include BFV-300


Wet Pilot Deluge System with Galvanised Trim - Part No. System Size Approval & Listings
T x T ISO G xG F x G ISO F x F ISO F x G ANSI F x F ANSI DN In UL FM VdS LPCB
550170115 550110115 – – – – 40 1-1 ⁄ 2" √ √ √ √
550170120 550110120 – – – – 50 2" √ √ √ √
– 550110130 550150130 550140130 550130130 550120130 80 3" √ √ √ √
– 550110140 550150140 550140140 550130140 550120140 100 4" √ √ √ √
– 550110160 550150160 550140160 550130160 550120160 150 6" √ √ √ √
– 550110180 550150180 550140180 550130180 550120180 200 8" √ √ √ √

System Size Dimension mm Pos. Description


DN In A B C D E F G H J A DV-5a Valve
40 1-1 ⁄ 2" 71 246 264 323 411 185 259 203 31 B System Main Control Valve
50 2" 71 246 264 323 411 185 259 97 74 C Waterflow Pressure Switch
80 3" 76 277 305 320 455 147 351 99 91 D Main Drain Valve
100 4" 76 310 333 358 498 130 427 114 109 E System Drain Valve
150 6" 114 345 381 417 566 86 569 150 145 F Automatic Drain Valve
200 8" 135 414 437 495 699 74 699 132 170 G Alarm Test Valve
H Alarm Control Valve (Optional)
L
J Water Supply Gauge
K Diaphragm Gauge
C L System Gauge (Optional)
P4 M Manual Control Station
P7
F N Manual Reset Actuator
C2
P5 P Diaphragm Supply Valve
C4 Q Diaphragm Supply Strainer
C3
C1 Diaphragm Supply Connection
D
P6 C2 Water Motor Alarm Connection
C3 Wet Pilot Line Connection
H A
P3 Waterflow Pressure Alarm Switch
C4
C6 M Connection
P1
P2 C5 C5 Main Drain Connection
E C6 Drip Funnel Drain Connection
P1 Diaphragm Chamber Supply
J K P2 Water Supply Pressure & Alarm Test
B
P3 Alarm Actuation
N P4 Automatic Drain Valve
P5 System Drain
Q P6 Main Drain
G P7 System Air Supply Not Used for Deluge
P
C1

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–45
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Deluge & Preaction Systems

DV-5A Deluge Systems, Dry Pilot


J B C D
A

E
G

H F

Part Number do not include BFV-300

Dry Pilot Deluge System with Galvanised Trim - Part No. System Size Approval & Listings
T x T ISO G xG F x G ISO F x F ISO F x G ANSI F x F ANSI DN In UL FM VdS LPCB
550170215 550110215 – – – – 40 1-1 ⁄ 2" √ √ √ √
550170220 550110220 – – – – 50 2" √ √ √ √
– 550110230 550150230 550140230 550130230 550120230 80 3" √ √ √ √
– 550110240 550150240 550140240 550130240 550120240 100 4" √ √ √ √
– 550110260 550150260 550140260 550130260 550120260 150 6" √ √ √ √
– 550110280 550150280 550140280 550130280 550120280 200 8" √ √ √ √

System Size Dimension mm Pos. Description


DN In A B C D E F G H J A DV-5a Valve
40 1
1- ⁄ 2" 71 246 264 419 490 185 259 203 31 B System Main Control Valve
C Waterflow Pressure Switch
50 2" 71 246 264 419 490 185 259 97 74
D Main Drain Valve
80 3" 76 290 305 419 539 147 350 99 91
E System Drain Valve
100 4" 76 323 333 419 577 130 427 114 109 F Automatic Drain Valve
150 6" 114 356 381 419 645 86 569 150 145 G Alarm Test Valve
200 8" 135 427 437 495 711 74 699 132 170 H Alarm Control Valve (Optional)
J Water Supply Gauge
S
C3 V K Diaphragm Gauge
L System Gauge (Optional)
C6 M Manual Control Station
L U N Manual Reset Actuator
P Diaphragm Supply Valve
T
Q Diaphragm Supply Strainer
C
P4 C4 R Dry Pilot Actuator
P7
S Dry Pilot Low Pressure Switch
F
P5
T Dry Pilot Air Supply Valve
C2 U Dry Pilot Line Gauge
C5
R V Pressure Relief Valve
D C1 Diaphragm Supply Connection
P6
C2 Water Motor Alarm Connection
H A C3 Dry Pilot Line Connection
P3

P1 C8 M C4 Dry Pilot Air Supply Connection


P2 C7 Waterflow Pressure Alarm Switch
E C5
Connection
C6 Low Air Pressure Switch Connection
J
B
K C7 Main Drain Connection
C8 Drip Funnel Drain Connection
N P1 Diaphragm Chamber Supply
Q
P2 Water Supply Pressure & Alarm Test
G P3 Alarm Actuation
P P4 Automatic Drain Valve
C1 P5 System Drain
P6 Main Drain
P7 System Air Supply Not Used for Deluge

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–46
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Deluge & Preaction Systems

DV-5A Deluge Systems, Electric Actuation


J B C D
A

E
G

H F

Part Number do not include BFV-300

Electric Actuation Deluge System with Galvanised Trim - Part No. System Size Approval & Listings
T x T ISO G xG F x G ISO F x F ISO F x G ANSI F x F ANSI DN In UL FM VdS LPCB
550170315 550110315 – – – – 40 1-1 ⁄ 2" √ √ √ √
550170320 550110320 – – – – 50 2" √ √ √ √
– 550110330 550150330 550140330 550130330 550120330 80 3" √ √ √ √
– 550110340 550150340 550140340 550130340 550120340 100 4" √ √ √ √
– 550110360 550150360 550140360 550130360 550120360 150 6" √ √ √ √
– 550110380 550150380 550140380 550130380 550120380 200 8" √ √ √ √

System Size Dimension mm Pos. Description


DN In A B C D E F G H J A DV-5a Valve
40 1
1- ⁄ 2" 71 246 264 323 412 185 259 203 31 B System Main Control Valve
50 2" 71 246 264 323 412 185 259 97 74 C Waterflow Pressure Switch
D Main Drain Valve
80 3" 76 277 305 320 455 147 351 99 91
E System Drain Valve
100 4" 76 310 333 358 498 129 427 114 109 F Automatic Drain Valve
150 6" 114 345 381 417 566 86 569 150 145 G Alarm Test Valve
200 8" 135 414 437 495 699 74 699 132 170 H Alarm Control Valve (Optional)
J Water Supply Gauge
L K Diaphragm Gauge
L System Gauge (Optional)
C
M Manual Control Station
P4 N Manual Reset Actuator
P7 R
F
P Diaphragm Supply Valve
P5 Q Diaphragm Supply Strainer
C2 R Solenoid Valve
C3
C1 Diaphragm Supply Connection
D C2 Water Motor Alarm Connection
P6
Waterflow Pressure Alarm Switch
C3
H
P3 A Connection
C4 Main Drain Connection
P1 C5 M
P2
C5 Drip Funnel Drain Connection
C4
E P1 Diaphragm Chamber Supply
P2 Water Supply Pressure & Alarm Test
P3 Alarm Actuation
J K
B P4 Automatic Drain Valve
N P5 System Drain
P6 Main Drain
Q P7 System Air Supply Not Used for Deluge
G
P
C1

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–47
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Deluge & Preaction Systems

DV-5A Deluge Systems, Remote Resetting


J B C D
A

E
G

H F

Part Number do not include BFV-300

Remote Resetting Deluge System with Galvanised Trim - Part No. System Size Approval & Listings
T x T ISO G xG F x G ISO F x F ISO F x G ANSI F x F ANSI DN In UL VdS
550170415 550110415 – – – – 40 1-1 ⁄ 2" √ √
550170420 550110420 – – – – 50 2" √ √
– 550110430 550150430 550140430 550130430 550120430 80 3" √ √
– 550110440 550150440 550140440 550130440 550120440 100 4" √ √
– 550110460 550150460 550140460 550130460 550120460 150 6" √ √
– 550110480 550150480 550140480 550130480 550120480 200 8" √ √

System Size Dimension mm Pos. Description


DN In A B C D E F G H J A DV-5A Valve
40 1-1 ⁄ 2" 71 279 264 373 427 185 259 203 30 B System Main Control Valve
50 2" 71 279 264 373 427 185 259 97 74 C Waterflow Pressure Switch
80 3" 76 279 305 389 505 147 351 99 91 D Main Drain Valve
100 4" 76 323 333 424 566 130 427 114 109 E System Drain Valve
150 6" 114 343 381 472 663 84 569 150 145 F Automatic Drain Valve
200 8" 135 424 437 493 777 74 699 132 170 G Alarm Test Valve
H Alarm Control Valve (Optional)
C
J Water Supply Gauge
C3 K Diaphragm Gauge
C2 L (Not Used)
M Manual Control Station
H N Solenoid Valve
P Diaphragm Supply Valve
Q Diaphragm Supply Strainer
P4 C1 Diaphragm Supply Connection
P7 C2 Water Motor Alarm Connection
P5 Waterflow Pressure Alarm Switch
C3
N
Connection
D F
P6 C4 Main Drain Connection
C5 Drip Funnel Drain Connection
P3 A K
P1 Diaphragm Chamber Supply
P1
P2 C4
P2 Water Supply Pressure & Alarm Test
E
P3 Not Used
C5
P4 Not Used
J
B P5 System Drain
M P6 Main Drain
P7 Alarm Actuation
G

P
C1

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–48
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Deluge & Preaction Systems

DV-5A Deluge Systems, Remote Resetting, Pressure Reducing


J B C D
A

H F

Part Number do not include BFV-300


Remote Resetting, Pressure Reducing Deluge System with Galvanised Trim - Part No. System Size Approval & Listings
G xG F x G ISO F x F ISO F x G ANSI F x F ANSI DN In UL
550110530 550150530 550140530 550130530 550120530 80 3" √
550110540 550150540 550140540 550130540 550120540 100 4" √
550110560 550150560 550140560 550130560 550120560 150 6" √
550110580 550150580 550140580 550130580 550120580 200 8" √

System Size Dimension mm Pos. Description


DN In A B C D E F G H J A DV-5A Valve
80 3" 75 302 360 476 590 135 349 96 91 B System Main Control Valve
100 4" 76 335 360 480 628 133 425 115 109 C Waterflow Pressure Switch
150 6" 115 370 386 527 699 107 569 148 145 D Main Drain Valve
200 8" 136 436 448 550 780 6 697 133 170 E System Drain Valve
C F Automatic Drain Valve
G Alarm Test Valve
C3
H Alarm Control Valve (Optional)
C2 J Water Supply Gauge
K Diaphragm Gauge
L (Not Used)
H
M Manual Control Station
P4 N Solenoid Valve
P7 P Diaphragm Supply Valve
P5 Q Diaphragm Supply Strainer
C1 Diaphragm Supply Connection
N
D C2 Water Motor Alarm Connection
P6
Waterflow Pressure Alarm Switch
K C3
P3 A F Connection
C4 Main Drain Connection
P1
P2 C4 C5 Drip Funnel Drain Connection
P1 Diaphragm Chamber Supply
E
P2 Water Supply Pressure & Alarm Test
J P3 Not Used
B
C5
P4 Not Used
M
P5 System Drain
G
P6 Main Drain
P7 Alarm Actuation
Q

P
C1

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–49
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Deluge & Preaction Systems


Model BW

Wafer Butterfly Valve


Sizes DN80 - DN200 (3" thru 8")

Approvals LPCB

Body Leaded Gunmetal

Maximum Service 16 bar (230 psi) Water,


Pressure 4 bar (58 psi) Air

Tech Data Sheet Contact Tyco for details

Model BW Deluge Wafer Butterfly Valve


Part No. H Weight Approval & Listings
DN PN
Vertical Horizontal mm kg LPCB
02408 02411 80 3” 95 PN16 12 √
02333 02366 100 4” 115 PN16 14 √
02326 02353 150 6” 127 PN16 22 √
02370 02687 200 8” 160 PN16 38 √

Model BW Deluge Wafer Butterfly Valve Trim


Part No. H
DN
Standard Air/Water mm
02409K 03254K 80 3” 95
02334K 03200K 100 4” 115 H
02201K 03201K 150 6” 127
02371K 03202K 200 8” 160

Model BW Deluge Wafer Butterfly Valve - Pressure


Pressure
Water Air
Bar Bar
4-6 2,3
8 - 12 3,3
14 - 16 4,0

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–50
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Deluge & Preaction Systems

Single Interlock Preaction Systems

Wet Pilot, Dry Pilot, or Electric Actuation

The DV-5A Supervised single interlock preaction systems


are used to protect areas where there is danger of
serious water damage that might result from damaged
automatic sprinklers or piping. Typically, such areas
include computer rooms, storage areas for valuable
artifacts, libraries and archives. Also, preaction systems
are effectively used to protect properties where a
prealarm of a possible fire condition may allow time for
fire extinguishment by alternate suppression means, prior
to a sprinkler discharge. In the event the fire cannot be
extinguished, the preaction sprinkler system will then
perform as the primary fire protection system.
Single interlock preaction systems employ automatic
sprinklers attached to a piping system containing 0,7
bar (10 psi) supervisory pressure, with a supplemental
electric fire detection system installed in the same area
as the sprinklers. Preaction systems with 0,7 bar (10 psi)
supervisory pressure may also be activated by either
wet or dry pilot sprinklers instead of electric detectors.
Actuation of the fire detection system from a fire opens
the deluge valve, allowing water to flow into the sprinkler
piping system and to be discharged only from those
sprinklers that have been operated by heat over the fire.
Loss of supervisory pressure from the system piping
as a result of damaged sprinklers or broken piping will
activate a trouble alarm to indicate impairment of the
system. The deluge valve will not open due to loss of
supervisory pressure.

DV-5A Size Range DN40 thru DN200 (11 ⁄ 2" thru 8")

Approvals UL, C-UL Listed & FM Approved

Maximum Service Wet Pilot Actuation: 20,7 bar (300 psi)


Pressure Preaction Dry Pilot Actuation: 17,2 bar (250 psi)
Single Interlock Trim Electric Actuation: Per Solenoid, see TFP2180

Thread x Thread, Groove x Groove,


End Connection
Flange x Flange, Flange x Groove

Flange Drilling ANSI, ISO, AS, & JIS

Tech Data Sheet TFP1425

Vertical installation • One internal working part, Diaphragm operation • No linkage or clapper assembly • Light weight ductile iron
body • Internally & externally coated • Features external resetting • For deluge, preaction & foam systems

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–51
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Deluge & Preaction Systems

DV-5A Single Interlock Preaction System, Wet Pilot


J B C D
A

E
G

H F

Part Number do not include BFV-300

Single Interlock Wet Pilot Preaction System with Galvanised Trim - Part No. System Size Approval & Listings
T x T ISO G xG F x G ISO F x F ISO F x G ANSI F x F ANSI DN In UL FM
550171115 550111115 – – – – 40 1-1 ⁄ 2" √ √
550171120 550111120 – – – – 50 2" √ √
– 550111130 550151130 550141130 550131130 550121130 80 3" √ √
– 550111140 550151140 550141140 550131140 550121140 100 4" √ √
– 550111160 550151160 550141160 550131160 550121160 150 6" √ √
– 550111180 550151180 550141180 550131180 550121180 200 8" √ √

System Size Dimension mm Pos. Description


DN In A B C D E F G H J A DV-5a Valve
40 1-1/2" 71 246 264 399 411 185 259 203 31 B System Main Control Valve
50 2" 71 246 264 399 411 185 259 97 74 C Waterflow Pressure Switch
80 3" 76 277 305 414 470 147 351 99 91 D Main Drain Valve
100 4" 76 310 333 419 533 130 427 114 109 E System Drain Valve
150 6" 114 345 381 467 630 86 569 150 145 F Automatic Drain Valve
200 8" 135 414 437 495 739 74 699 132 170 G Alarm Test Valve
H Alarm Control Valve (Optional)
T J Water Supply Gauge
K Diaphragm Gauge
L System Gauge
C6
M Manual Control Station
L
N Manual Reset Actuator
P Diaphragm Supply Valve
C Q Diaphragm Supply Strainer
P7
P4 R Supervisory Air Supply Valve
F S Supervisory Air Pressure Relief Valve
R
C2
P5 T Supervisory Low Pressure Switch
C5
C3 C1 Diaphragm Supply Connection
D C2 Water Motor Alarm Connection
P6
S C3 Wet Pilot Line Connection
H A C4 C4 Supervisory Air Supply Connection
P3

P1 C8 M Waterflow Pressure Alarm Switch


C5
P2 C7 Connection
E
C6 Low Air Pressure Alarm Switch
C7 Main Drain Connection
J K
B C8 Drip Funnel Drain Connection
N P1 Diaphragm Chamber Supply
P2 Water Supply Pressure & Alarm Test
Q
G
P3 Alarm Actuation
P4 Automatic Drain Valve
P
C1 P5 System Drain
P6 Main Drain
P7 System Air Supply

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–52
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Deluge & Preaction Systems
DV-5A Single Interlock Preaction System, Dry Pilot
J B C D
A

E
G

H F

Part Number do not include BFV-300


Single Interlock Dry Pilot Preaction System with Galvanised Trim - Part No. System Size Approval & Listings
T x T ISO G xG F x G ISO F x F ISO F x G ANSI F x F ANSI DN In UL FM
550171215 550111215 – – – – 40 1-1 ⁄ 2" √ √
550171220 550111220 – – – – 50 2" √ √
– 550111230 550151230 550141230 550131230 550121230 80 3" √ √
– 550111240 550151240 550141240 550131240 550121240 100 4" √ √
– 550111260 550151260 550141260 550131260 550121260 150 6" √ √
– 550111280 550151280 550141280 550131280 550121280 200 8" √ √

System Size Dimension mm Pos. Description


DN In A B C D E F G H J A DV-5a Valve
40 1-1/2" 71 246 264 419 493 185 259 203 31 B System Main Control Valve
C Waterflow Pressure Switch
50 2" 71 246 264 419 493 185 259 97 74
D Main Drain Valve
80 3" 76 290 305 419 539 147 351 99 91
E System Drain Valve
100 4" 76 323 333 419 574 130 427 114 109 F Automatic Drain Valve
150 6" 114 356 381 467 645 86 569 150 145 G Alarm Test Valve
200 8" 135 427 437 495 739 74 699 132 170 H Alarm Control Valve (Optional)
J Water Supply Gauge
T L K Diaphragm Gauge
V
C3
L System Gauge
C7 M Manual Control Station
C7 Y N Manual Reset Actuator
X P Diaphragm Supply Valve
R Q Diaphragm Supply Strainer
C W R Supervisory Air Supply Valve
P4 C4
P7 S Supervisory Air Pressure Relief Valve
F
P5
T Supervisory Low Pressure Switch
S
C2
C6 C5
U Dry Pilot Actuator
D
U V Dry Pilot Low Pressure Switch
P6 W Dry Pilot Air Supply Valve
H A X Dry Pilot Line Gauge
P3
C9 M
Y Dry Pilot Air Pressure Relief Valve
P1
P2 C8
C1 Diaphragm Supply Connection
E C2 Water Motor Alarm Connection
C3 Dry Pilot Line Connection
J
B
K C4 Dry Pilot Air Supply Connection
N C5 Supervisory Air Supply Connection
Waterflow Pressure Alarm Switch
Q C6
G
Connection
P
C7 Low Air Pressure Alarm Switch Connection
C1 C8 Main Drain Connection
C9 Drip Funnel Connection
P1 Diaphragm Chamber Supply
P2 Water Supply Pressure & Alarm Test
P3 Alarm Actuation
P4 Automatic Drain Valve
P5 System Drain
P6 Main Drain
P7 System Air Supply
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–53
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Deluge & Preaction Systems


DV-5A Single Interlock Preaction System, Electric Actuation
J B C D
A

E
G

H F

Part Number do not include BFV-300

Single Interlock Electric Actuation Preaction System with Galvanised Trim - Part No. System Size Approval & Listings
T x T ISO G xG F x G ISO F x F ISO F x G ANSI F x F ANSI DN In UL FM
550171315 550111315 – – – – 40 1-1 ⁄ 2" √ √
550171320 550111320 – – – – 50 2" √ √
– 550111330 550151330 550141330 550131330 550121330 80 3" √ √
– 550111340 550151340 550141340 550131340 550121340 100 4" √ √
– 550111360 550151360 550141360 550131360 550121360 150 6" √ √
– 550111380 550151380 550141380 550131380 550121380 200 8" √ √

System Size Dimension mm Pos. Description


DN In A B C D E F G H J A DV-5a Valve
40 1-1/2" 71 246 264 399 411 185 259 203 31 B System Main Control Valve
C Waterflow Pressure Switch
50 2" 71 246 264 399 411 185 259 97 74
D Main Drain Valve
80 3" 76 277 305 414 470 147 351 99 91 E System Drain Valve
100 4" 76 310 333 419 533 130 427 114 109 F Automatic Drain Valve
150 6" 114 345 381 467 630 86 569 150 145 G Alarm Test Valve
H Alarm Control Valve (Optional)
200 8" 135 414 437 495 742 74 699 132 170
J Water Supply Gauge
T K Diaphragm Gauge
L System Gauge
M Manual Control Station
C5
N Manual Reset Actuator
L
P Diaphragm Supply Valve
Q Diaphragm Supply Strainer
R Supervisory Air Supply Valve
C S Supervisory Air Pressure Relief Valve
P4
P7 U T Supervisory Low Pressure Switch
F U Solenoid Valve
R
P5
C2
C4
S C1 Diaphragm Supply Connection
C2 Water Motor Alarm Connection
D C3 Supervisory Air Supply Connection
P6
Waterflow Pressure Alarm Switch
C4
H
P3 A C3 Connection
M Low Air Pressure Alarm Switch
P1 C7 C5
P2 C6 Connection
E C6 Main Drain Connection
C7 Drip Funnel Drain Connection
J K P1 Diaphragm Chamber Supply
B
P2 Water Supply Pressure & Alarm Test
N P3 Alarm Actuation
Q
P4 Automatic Drain Valve
G P5 System Drain
P P6 Main Drain
C1 P7 System Air Supply

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–54
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Deluge & Preaction Systems

Double Interlock Preaction Systems

Electric/Electric or Electric/Pneumatic Actuation

The DV-5A Double Interlock Preaction Systems are


designed for applications such as refrigerated areas
that require the maximum degree of protection against
inadvertent flooding of the sprinkler system piping.
The double interlock system consists of a consists of a
DV-5A deluge valve with integrated alarm port and with
a releasing trim featuring both a solenoid valve and a dry
pilot actuator in a series configuration. The system water
pressure is isolated by the DV-5A valve from system air or
nitrogen pressure that holds the dry pilot actuator closed.
The solenoid valve remains closed until it is electrically
energized by a deluge releasing panel that responds to the
operation of a fire detection device.
In order to actuate the double interlock preaction system,
two independent events, caused by a fire condition, must
occur. The sprinkler system piping must lose air or
nitrogen pressure due to the operation of one or more
sprinklers, and the deluge releasing panel must energize
and open the solenoid valve upon the operation of a fire
detection device.
The double interlock system will operate only when both
the dry pilot actuator and the solenoid valve are open at
the same time. Opening of the dry pilot actuator only (for
example: a forklift truck accidentally dislodges a sprinkler)
or of the solenoid valve only (for example: accidental
operation of an electric manual pull station) will cause an
alarm, and will not trip the system or flood the sprinkler
system piping.

DV-5A Size Range DN40 thru DN200 (11 ⁄ 2" thru 8")

Approvals UL, C-UL Listed & FM Approved

Preaction Double Electric/Electric Actuation,


Interlock Trim Electric/Pneumatic Actuation

Thread x Thread, Groove x Groove,


End Connection
Flange x Flange, Flange x Groove

Flange Drilling ANSI, ISO, AS, & JIS

Tech Data Sheet TFP1450

Vertical installation • One internal working part, Diaphragm operation • No linkage or clapper assembly • Light weight ductile iron
body • Internally & externally coated • Features external resetting • For deluge, preaction & foam systems

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–55
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Deluge & Preaction Systems

DV-5A Double Interlock Preaction System, Electric/Electric Actuation


J B C D
A

E
G

H F

Part Number do not include BFV-300


Double Interlock Electric/ Electric Preaction System with Galvanised Trim - Part No. System Size Approval & Listings
T x T ISO G xG F x G ISO F x F ISO F x G ANSI F x F ANSI DN In UL FM
550171515 550111515 – – – – 40 1-1 ⁄ 2" √ √
550171520 550111520 – – – – 50 2" √ √
– 550111530 550151530 550141530 550131530 550121530 80 3" √ √
– 550111540 550151540 550141540 550131540 550121540 100 4" √ √
– 550111560 550151560 550141560 550131560 550121560 150 6" √ √
– 550111580 550151580 550141580 550131580 550121580 200 8" √ √

System Size Dimension mm Pos. Description


DN In A B C D E F G H J A DV-5a Valve
40 1-1/2" 71 246 264 399 412 185 259 203 31 B System Main Control Valve
C Waterflow Pressure Switch
50 2" 71 246 264 399 412 185 259 97 74
D Main Drain Valve
80 3" 76 277 305 414 470 147 351 99 91
E System Drain Valve
100 4" 76 310 333 419 533 129 427 114 109
F Automatic Drain Valve
150 6" 114 345 381 467 630 86 569 150 145 G Alarm Test Valve
200 8" 135 414 437 495 739 74 699 132 170 H Alarm Control Valve (Optional)
J Water Supply Gauge
T K Diaphragm Gauge
L System Gauge
M Manual Control Station
C5
N Manual Reset Actuator
L
P Diaphragm Supply Valve
Q Diaphragm Supply Strainer
R Air Supply Valve
C S Air Pressure Relief Valve
W P4
P7 U T Low Pressure Switch
F
R U Solenoid Valve
P5
C2 S V Not Used
C4
W System Shut-Off Valve (Shown in Figure 4)
D
P6 C1 Diaphragm Supply Connection
C2 Water Motor Alarm Connection
H A C3
P3 C3 Air Supply Connection
P1 C7 M Waterflow Pressure Alarm Switch
C4
P2 C6 Connection
E
C5 Low Air Pressure Switch Connection
C6 Main Drain Connection
J K
B C7 Drip Funnel Drain Connection
N P1 Diaphragm Chamber Supply
P2 Water Supply Pressure & Alarm Test
Q P3 Alarm Actuation
G
P4 Automatic Drain Valve
P
C1 P5 System Drain
P6 Main Drain
P7 System Air Supply

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–56
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Deluge & Preaction Systems

DV-5A Double Interlock Preaction System, Electric/Pneumatic Actuation


J B C D
A

E
G

H F

Part Number do not include BFV-300

Double Interlock Electric/ Pneumatic Preaction System with Galv. Trim - Part No. System Size Approval & Listings
T x T ISO G xG F x G ISO F x F ISO F x G ANSI F x F ANSI DN In UL FM
550171415 550111415 – – – – 40 1-1 ⁄ 2" √ √
550171420 550111420 – – – – 50 2" √ √
– 550111430 550151430 550141430 550131430 550121430 80 3" √ √
– 550111440 550151440 550141440 550131440 550121440 100 4" √ √
– 550111460 550151460 550141460 550131460 550121460 150 6" √ √
– 550111480 550151480 550141480 550131480 550121480 200 8" √ √

System Size Dimension mm Pos. Description


DN In A B C D E F G H J A DV-5a Valve
40 1-1/2" 71 246 264 399 427 185) 259 203 31 B System Main Control Valve
50 2" 71 246 264 399 427 185) 259 97 74 C Waterflow Pressure Switch
D Main Drain Valve
80 3" 76 290 305 414 472 147) 351 99 91
E System Drain Valve
100 4" 76 323 333 419 533 129) 427 114 109 F Automatic Drain Valve
150 6" 114 356 381 467 630 86) 569 150 145 G Alarm Test Valve
200 8" 135 427 437 495 739 74) 699 132 170 H Alarm Control Valve (Optional)
J Water Supply Gauge
T
L K Diaphragm Gauge
L System Gauge
C5 M Manual Control Station
N Manual Reset Actuator
P Diaphragm Supply Valve
R Q Diaphragm Supply Strainer
C R Air Supply Valve
W P4
P7 V S Air Pressure Relief Valve
F
P5
T Low Pressure Switch
C2 S
C4 C3 U Solenoid Valve
D
U V Dry Pilot Actuator
P6 W System Shut-Off Valve
H A C1 Diaphragm Supply Connection
P3
M
C2 Water Motor Alarm Connection
P1 C7
P2 C6
C3 Air Supply Connection
E Waterflow Pressure Alarm Switch
C4
Connection
J
B
K C5 Low Air Pressure Switch Connection
N
C6 Main Drain Connection
C7 Drip Funnel Drain Connection
Q P1 Diaphragm Chamber Supply
G
P2 Water Supply Pressure & Alarm Test
P
C1 P3 Alarm Actuation
P4 Automatic Drain Valve
P5 System Drain
P6 Main Drain
P7 System Air Supply
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–57
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Deluge & Preaction Systems

DV-5A Double Interlock Preaction System, Type A


J B C D
A

H F

Part Number do not include BFV-300

Type A Preaction System with Galvanised Trim - Part No. System Size Approval & Listings
T x T ISO G xG F x G ISO F x F ISO F x G ANSI F x F ANSI DN In VdS
550171615 550111615 – – – – 40 1-1 ⁄ 2" √
550171620 550111620 – – – – 50 2" √
– 550111630 550151630 550141630 550131630 550121630 80 3" √
– 550111640 550151640 550141640 550131640 550121640 100 4" √
– 550111660 550151660 550141660 550131660 550121660 150 6" √
– 550111680 550151680 550141680 550131680 550121680 200 8" √

System Size Dimension mm Pos. Description


DN In A B C D E F G H J A DV-5a Valve
40 1-1/2" 71 267 264 498 569 185 259 203 31 B System Main Control Valve
C Waterflow Pressure Switch
50 2" 71 267 264 498 566 185 259 97 74
D Main Drain Valve
80 3" 76 328 305 500 612 147 351 99 91
E System Drain Valve
100 4" 76 361 333 480 650 130 427 114 109 F Automatic Drain Valve
150 6" 114 396 381 577 724 86 569 150 145 G Alarm Test Valve
200 8" 135 414 437 615 785 74 699 132 170 H Alarm Control Valve (Optional)
J Water Supply Gauge
K Diaphragm Gauge
L System Gauge
M Manual Control Station
Z
N Manual Reset Actuator
V
L Y P Diaphragm Supply Valve
Q Diaphragm Supply Strainer
C5 R Solenoid Valve (NC) De-Energized #1
S Solenoid Valve (NC) Energized #2
X
T Dry Pilot Actuator
U Pressure Relief Valve
R
S V Supervisory Low Pressure Alarm Switch
C W Air Supply Strainer
P4
P7
F
T
U
X Air Supply Control Valve "A"
C3 Y Air Supply Control Valve "B"
P5
C2
C4 Z Dry Pilot Gauge
D C1 Diaphragm Supply Connection
P6 W C2 Water Motor Alarm Connection
H
P3 A C3 Air Supply Connection
M
C7 Waterflow Pressure Alarm Switch
P1 C4
P2 C6 Connection
E
C5 Low Air Pressure Switch Connection
C6 Main Drain Connection
J K
B C7 Drip Funnel Drain Connection
N P1 Diaphragm Chamber Supply
Q
P2 Water Supply Pressure & Alarm Test
G P3 Alarm Actuation
P P4 Automatic Drain Valve
C1 P5 System Drain
P6 Main Drain
P7 System Air Supply

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–58
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Deluge & Preaction Systems

DPV-1 Preaction, Type B Valves EN12845 Compliance

Standard Assembly:
Dry Alarm Valve: [DPV-1]
Pressure Alarm Switch: [PS10-1]
Actuation: Electric or Dry
No Stop Valve
Tech Data Sheet: TFP1486
*For Stop Valve see chapter 3, to be ordered separately

Type B Preaction System with Galvanised Trim - Part No. System Size Approval & Listings
G xG F x G PN16 F x F PN16 DN mm VdS
2B49000101 2849000101 2749000101 100 4" √
2B79000101 2879000101 2779000101 150 165,1 √
2B69000101 2869000101 2769000101 150 168,3 (6") √
* This is a dry pipe system in which the alarm valve station is opened either by an automatic fire detection system or by the operation of the
sprinklers. Independently of the response of the detectors, a pressure drop in the pipework causes the opening of the alarm valve

System Size Dimension mm


DN In A B C D E F G
100 4" 349 507 376 150 193 490 137
150 165,1mm 406 509 375 184 211 475 135
150 6" (168,3mm) 406 509 375 184 211 475 135

E* D B* C*

F*

LEFT VIEW FRONT VIEW

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–59
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Deluge & Preaction Systems


Spare Kits

Spare Kits

Tech Data Sheet Contact Tyco for details

Replacement Parts

Size Weight
Part No. Model Description
DN In. kg
922001216 65 2-1/2” 0.10
922001416 100 4” 0.12
AV-1 Clapper facing and handhole cover gasket
922001620 150 6” 0.18
922001816 200 8” 0.20
922801008 DP-1 Diaphragm 0.10
923091204 65-80 2 1/2”-3 0.20
923091404 DPV-1 100 4” Cover gaskets, Clapper facing, O-rings and Grease 0.24
923091604 150 6” 0.34
924141216 50 2” 0.1
A-2
923021416 100 4” Cover gaskets, Clapper facing, O-rings and Grease 0.24
F302/F3021
923021617 150 6” 0.34
O-rings, Cover gasket, Plunger, Restriction and
923111116 ACC-1 - - 0.2
Exhaust valve
924771105 40 1-1/2” 0.3
924771107 50 2” 0.4
924771109 80 3” 0.4
DV-5 Diaphragm
924771101 100 4” 0.5
924771103 150 6” 0.6
924771111 200 8” 0.8
924701101 100 4” 0.5
DV-1 Cover gasket, Diaphragm and Clapper facing
924701102 150 6” 0.5
920201116 DV-2 50 2” Body gasket, Diaphragm and Facing 0.15
03090 80 3” 0.5
03091 100 4” Clack Seal, Washers, Valve Port, Grease, 0.5
BW-DEL
03092 150 6” Diaphragms and Screws 0.5
03093 200 8” 1
03090AL 80 3” 0.5
03091AL 100 4” 0.5
BW-WET Clack Seal, Washers, Valve Port, Grease and Screws
03092AL 150 6” 0.5
03093AL 200 8” 1
33024 100 4” 0.2
33025 100 4” 0.2
33035 150 6” 0.3
LW Clack Seal, Cover Gasket
33037 150 6” 0.5
33046 200 8” 0.4
33050 200 8” 0.5

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–60
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Deluge & Preaction Systems
Fire Department Connections

Straight & 90° Fire Department Connections

90° Side Outlet Pattern


Pattern
Straight -Through Siamese Pattern

Tech Data Sheet Contact Tyco for details

Designed for fire department use to increase water pressure and volume to automatic sprinkler system or standard-pipe system

Hangers

Pipe Hangers

Tech Data Sheet Contact Tyco for details

A full-line of pipe hangers for every fire protection need • Manufactured to meet the quality standards that the industry demands •
Meet the requirements of NFPA 13

4410-RC
Releasing Panel

Approvals UL Listed & FM Approved

Tech Data Sheet Contact Tyco for details

Provides the interface between detection system, deluge or single or double interlocked preaction valve, and signaling circuit and
devices in electrically actuated fire protection systems • Separate supervisory zone provided for electronic supervision of valve
position, low pressure, and other critical fire protection functions • Can be used in single zone, cross zone, sequential or cross/
sequential electric deduction systems • Has programming capability

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 3–61
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Deluge & Preaction Systems


Notes

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

3–62
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves
Designed for use in wet pipe sprinkler systems.

- Prevention of Reverse Flow - Closure of Fire Protection


After Operation
- System Shut-off
- Facilitation of System Testing
- Sectional Control

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–1
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Shut Off Valves


BFV-300

Grooved End Butterfly Valve


Sizes DN50 thru DN300 (2" thru 12")

UL & ULC Listed, FM Approved, CE Certified


VdS Approved, Russian Fire Certificate
Approvals
CNPP R1 Listed – APSAD
Listed by California State Fire Marshall
UL/FM Maximum Working Pressure
DN50 – DN200 (2" – 8") 20,7 bar (300 psi)
DN250 – DN300 (10" – 12") 12,1 bar (175 psi)
Maximum Working
Pressure VdS Maximum Working Pressure
DN50 – DN200 (2" – 8") 20,7 bar (300 psi)
DN250 (10") 16,0 bar (232 psi)
DN300 (12") 12,1 bar (175 psi)
Maximum Working
100°C (212°F) in accordance with UL 1091
Temperature

End Connection Groove x Groove

Tech Data Sheet TFP1511

BFV-300 (Normally Open) and BFV-300C (Normally Closed) • Indicating type valves provide visual indication of whether the valve is
open or closed • Suitable for use with grooved pipe couplings that are listed or approved for fire protection service

SEGMENTED HANDWHEEL
HANDWHEEL GEAR OPERATOR INDICATOR HANDWHEEL
8 TO 12 INCH FLAG
(DN200 TO DN300) (VALVE
VALVE SIZES OPEN) TAPPING
BOSSES

TAPPING
BOSSES

TAPPING
ELECTRICAL TRAVELLING NUT TRAVELLING NUT
BOSSES
CONNECTOR GEAR OPERATOR GEAR OPERATOR
2 TO 4 INCH 5 TO 6 INCH
(DN50 TO DN100) (DN125 TO DN150)
VALVE SIZES VALVE SIZES

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–2
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Shut Off Valves
BFV-300 Grooved End Butterfly Valve
E
C D B

BODY
F

A
G

DISC
J H

Model BFV-300/BFV-300C Grooved End Butterfly Valve


Nominal
Pipe O.D. Dimension mm Weight
Valve Size
kg
DN In mm In. A B C D E F G H J
50 2" 60,3 2.37" 96,4 270 72,5 124,5 125 108,6 50,5 0 0 4,9
65 2-1 ⁄ 2" 73,0 2.88" 96,4 297,8 85 139,8 125 108,6 50,5 0 0 5,9
65 76,1mm 76,1 3.00" 96,4 297,8 85 139,8 125 108,6 50,5 0 0 5,9
80 3" 88,9 3.50" 96,4 310,3 91 146,3 125 108,6 50,5 0 0 6,3
100 4" 114,3 4.50" 115,4 353,5 109 171,5 125 108,6 50,5 0 0 8,0
125 139,7mm 139,7 5.50" 148 406,6 131 201,5 150 147 58,9 0 0 11,9
125 5" 141,3 5.56" 148 406,6 131 201,5 150 147 58,9 0 0 11,9
150 165,1mm 165,1 6.50" 148 433,6 145 214,5 150 147 58,9 0 0 13,8
150 6" 168,3 6.63" 148 433,6 145 214,5 150 147 58,9 0 0 13,8
200 8" 219,1 8.63" 133 499,5 170 236 225 208 70 143,7 31,4 21,4
250 10" 273 10.75" 159 570,5 195 282 283 208 74 183,1 41,8 33,3
300 12" 323,9 12.75" 165 645 241,5 310 283 208 74 252,9 68,5 40,5

BFV-300/BFV-300C Grooved End Butterfly Valve


Replacement Handwheel
Nominal
Part No.
Valve Size
BFV-300, BFV-300C,
DN In Red Painted Black Painted
Handwheel Handwheel
50 - 100 2" - 4" 59300SPHWHEEL10 59300SPHWHEEL10B
125 - 200 5" - 8" 59300SPHWHEEL20 59300SPHWHEEL20B
250 - 300 10" - 12" 59300SPHWHEEL30 59300SPHWHEEL30B

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–3
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Shut Off Valves


BFV-300 Grooved End Butterfly Valve

Model BFV-300/BFV-300C Grooved End Butterfly Valve


with Internal Supervisory Switches
Nominal
Pipe O.D. Part No. Approval & Listings
Valve Size Max
Pressure BFV-300 BFV-300C Fire
Bar UL/
DN In mm In. Supv. Switch Supv. Switch CE
ULC
FM EN VdS PAVUS Academy
OPEN CLOSED of Russia
50 2" 60,3 2.37" 20,7 59300G020WS 59300G020WSC √ √ √ √ √ √
65 2-1/2" 73,0 2.88" 20,7 59300G025WS 59300G025WSC √ √ √ √ √ √ √
65 76,1mm 76,1 3" 20,7 59300G026WS 59300G026WSC √ √ √ √ √ √ √
80 3" 88,9 3.5" 20,7 59300G030WS 59300G030WSC √ √ √ √ √ √ √
100 4" 114,3 4.5" 20,7 59300G040WS 59300G040WSC √ √ √ √ √ √ √
125 139,7mm 139,7 5.5" 20,7 59300G056WS 59300G056WSC √ √ √ √ √ √ √
125 5" 141,3 5.56" 20,7 59300G050WS 59300G050WSC √ √ √ √ √ √ √
150 165,1mm 165,1 6.5" 20,7 59300G066WS 59300G066WSC √ √ √ √ √ √ √
150 6" 168,3 6.63" 20,7 59300G060WS 59300G060WSC √ √ √ √ √ √ √
200 8" 219,1 8.63" 20,7 59300G080WS 59300G080WSC √ √ √ √ √ √ √
250 10" 273 10.75" 12,1 59300G100WS 59300G100WSC √ √ √ √ √ √ √
300 12" 323,9 12.75" 12,1 59300G120WS 59300G120WSC √ √ √ √ √ √

Model BFV-300/BFV-300C Grooved End Butterfly Valve


with CNPP-APSAD Large 100 X 100mm Flag and Internal Supervisory Switches
Nominal
Pipe O.D. Part No. Approval & Listings
Valve Size Max
Pressure BFV-300 BFV-300C
DN In mm In. Bar Supv. Switch Supv. Switch CE VdS
OPEN CLOSED
50 2" 60,3 2.37" 20,7 59300G020AWS 59300G020AWSC √ √
65 2-1/2" 73,0 2.88" 20,7 59300G025AWS 59300G025AWSC √ √
65 76,1mm 76,1 3" 20,7 59300G026AWS 59300G026AWSC √ √
80 3" 88,9 3.5" 20,7 59300G030AWS 59300G030AWSC √ √
100 4" 114,3 4.5" 20,7 59300G040AWS 59300G040AWSC √ √
125 139,7mm 139,7 5.5" 20,7 59300G056AWS 59300G056AWSC √ √
125 5" 141,3 5.56" 20,7 59300G050AWS 59300G050AWSC √ √
150 165,1mm 165,1 6.5" 20,7 59300G066AWS 59300G066AWSC √ √
150 6" 168,3 6.63" 20,7 59300G060AWS 59300G060AWSC √ √
200 8" 219,1 8.63" 20,7 59300G080AWS 59300G080AWSC √ √
250 10" 273 10.75" 12,1 59300G100AWS 59300G100AWSC √ √
300 12" 323,9 12.75" 12,1 59300G120AWS 59300G120AWSC √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–4
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Shut Off Valves
BFV-300 Grooved End Butterfly Valve

Model BFV-300/BFV-300C Grooved End Butterfly Valve


without Internal Supervisory Switches
Nominal
Pipe O.D. Approval & Listings
Valve Size Max
Pressure Part No. Fire
Bar UL/
DN In mm In. CE
ULC
FM EN VdS PAVUS Academy
of Russia
50 2" 60,3 2.37" 20,7 59300G020NS √ √ √ √ √ √
65 2-1 ⁄ 2" 73,0 2.88" 20,7 59300G025NS √ √ √ √ √ √ √
65 76,1mm 76,1 3.00" 20,7 59300G026NS √ √ √ √ √ √ √
80 3" 88,9 3.50" 20,7 59300G030NS √ √ √ √ √ √ √
100 4" 114,3 4.50" 20,7 59300G040NS √ √ √ √ √ √ √
125 139,7mm 139,7 5.50" 20,7 59300G056NS √ √ √ √ √ √ √
125 5" 141,3 5.56" 20,7 59300G050NS √ √ √ √ √ √ √
150 165,1mm 165,1 6.50" 20,7 59300G066NS √ √ √ √ √ √ √
150 6" 168,3 6.63" 20,7 59300G060NS √ √ √ √ √ √ √
200 8" 219,1 8.63" 20,7 59300G080NS √ √ √ √ √ √ √
250 10" 273,0 10.75" 12,1 59300G100NS √ √ √ √ √ √ √
300 12" 323,9 12.75" 12,1 59300G120NS √ √ √ √ √ √

Model BFV-300 Grooved End Butterfly Valve Without Internal Supervisory Switches
Accessory External Supervisory Switches And Mounting Brackets
Nominal
Part No.
Valve Size
Gear Bernstein
Operator Bernstein
Mounting Bernstein GC-SU1Z
Type I88-IP65
DN In Bracket with I88-IP65
LED Switch
Ex IP-66/67 ATEX
Mounting Bolts Regular Switch (Ex II2G Ex dIIC T6 Gb)
24V
Switch
50 2"
65 2-1 ⁄ 2"
65 76,1mm 59300SPBRACKET10
80 3"
100 4" Travelling Nut
125 139,7mm
59300SPSW 59300SPSWLED 59300SPSWATEX
125 5"
59300SPBRACKET20
150 165,1mm
150 6"
200 8" 59300SPBRACKET25
Segmented
250 10"
Gear 59300SPBRACKET30
300 12"

External Supervisory Switches


And Mounting Brackets

Bernstein Switch
Wiring Diagram

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–5
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Shut Off Valves


BFV-300
Wafer Style Butterfly Valve
Sizes DN50 thru DN300 (2" thru 12")

UL & ULC Listed, FM Approved, CE Certified


VdS Approved, Russian Fire Certificate
Approvals
CNPP R1 Listed – APSAD
Listed by California State Fire Marshall
UL/FM Maximum Working Pressure
DN50 – DN200 (2" – 8") 20,7 bar (300 psi)
DN250 – DN300 (10" – 12") 12,1 bar (175 psi)
Maximum Working
Pressure VdS Maximum Working Pressure
DN50 – DN200 (2" – 8") 20,7 bar (300 psi)
DN250 (10") 16,0 bar (232 psi)
DN300 (12") 12,1 bar (175 psi)
Maximum Working
100°C (212°F) in accordance with UL 1091
Temperature

End Connection Wafer

Tech Data Sheet TFP1516

Suitable for use installation between ANSI Class 125 or 150 flanges or PN10/16 flanges without the need for flange gaskets •
Indicating type valves provide visual indication of whether the valve is open or closed

HANDWHEEL SEGMENTED
GEAR OPERATOR HANDWHEEL
INDICATOR HANDWHEEL
8 TO 12 INCH
(DN200 TO DN300) FLAG
VALVE SIZES (VALVE
OPEN)

ELECTRICAL TRAVELLING NUT TRAVELLING NUT


CONNECTOR GEAR OPERATOR GEAR OPERATOR
2 TO 4 INCH 5 TO 6 INCH
(DN50 TO DN100) (DN125 TO DN150)
VALVE SIZES VALVE SIZES

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–6
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Shut Off Valves
BFV-300 Wafer Style Butterfly Valve
E

B C D

DISC GASKET
F

A
G
BODY

Model BFV-300/BFV-300C Wafer Style Butterfly Valve


Nominal
Dimension mm Weight
Valve Size
kg
DN In A B C D E F G H
50 2" 38 270,0 72,5 124,5 125 108,6 50,5 34 6,1
65 2-1 ⁄ 2" 46 296,5 85 138,5 125 108,6 50,5 41,9 6,1
80 3" 46 311,7 91 147,7 125 108,6 50,5 59,5 6,4
80 – 46 311,7 91 147,7 125 108,6 50,5 59,5 6,4
100 4" 55 353,5 109 171,5 125 108,6 50,5 82,6 6,8
125 5" 61 406,6 131 201,5 150 147 58,9 101,6 11,9
150 6" 61 433,6 145 214,5 150 147 58,9 132,6 11,1
200 8" 63 498,5 170 236 225 208 70 185,4 20
200 – 63 498,5 170 236 225 208 70 185,4 20
250 10" 74 584,5 210 282 283 208 74 230 29
300 12" 77 639,0 241,5 310 283 208 74 292,8 39,2

BFV-300/BFV-300C Wafer Style Butterfly Valve


Replacement Handwheel
Nominal
Part No.
Valve Size
Handwheel
DN In
50 - 100 2" - 4" 59300SPHWHEEL10
125 - 200 5" - 8" 59300SPHWHEEL20
250 - 300 10" - 12" 59300SPHWHEEL30

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–7
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Shut Off Valves


BFV-300 Wafer Style Butterfly Valve
Model BFV-300 Wafer Style Butterfly Valve
with Internal Supervisory Switches
Nominal
Part No. Approval & Listings
Valve Size Max
Flange
Pressure BFV-300 BFV-300 Fire
Face UL/
DN In Bar with without CE FM VdS EN PAVUS Academy
ULC
Internal Switch Internal Switch of Russia
50 2" ANSI 16.5, BS PN16 20,7 59300W020WS 59300W020NS √ √ √ √ √ √
65 2-1/2" ANSI 16.5, BS PN16 20,7 59300W025WS 59300W025NS √ √ √ √ √ √ √
80 3" ANSI 16.5 20,7 59300W030WS 59300W030NS √ √ √ √ √ √ √
80 – BS PN16 20,7 59300W036WS 59300W036NS √ √ √ √ √ √ √
ANSI 16.5, BS PN16,AS
100 4" 20,7 59300W040WS 59300W040NS √ √ √ √ √ √ √
2129 Table E
125 5" ANSI 16.5, BS PN16 20,7 59300W050WS 59300W050NS √ √ √ √ √ √ √
ANSI 16.5, BS PN16,AS
150 6" 20,7 59300W060WS 59300W060NS √ √ √ √ √ √ √
2129 Table E
200 8" ANSI 16.5, BS PN10 20,7 59300W080WS 59300W080NS √ √ √ √ √ √ √
200 – BS PN16 20,7 59300W086WS 59300W086NS √ √ √ √ √ √ √
250 10" ANSI 16.5,BS PN10/16 12,1 59300W100WS 59300W100NS √ √ √ √ √ √ √
300 12" ANSI 16.5,BS PN10/16 12,1 59300W120WS 59300W120NS √ √ √ √ √ √

Model BFV-300 Wafer Style Butterfly Valve


with CNPP-APSAD Large 100 X 100mm Flag and Internal Supervisory Switches
Nominal
Part No. Approval & Listings
Valve Size Max
Flange
Pressure BFV-300 BFV-300C
Face
DN In Bar Supv. Switch Supv. Switch CE VdS
OPEN CLOSED
50 2" ANSI 16.5, BS PN16 20,7 59300W020AWS 59300W020AWSC √ √
65 2-1/2" ANSI 16.5, BS PN16 20,7 59300W025AWS 59300W025AWSC √ √
80 3" ANSI 16.5 20,7 59300W030AWS 59300W030AWSC √ √
80 – BS PN16 20,7 59300W036AWS 59300W036AWSC √ √
ANSI 16.5, BS PN16,AS
100 4" 20,7 59300W040AWS 59300W040AWSC √ √
2129 Table E
125 5" ANSI 16.5, BS PN16 20,7 59300W050AWS 59300W050AWSC √ √
ANSI 16.5, BS PN16,AS
150 6" 20,7 59300W060AWS 59300W060AWSC √ √
2129 Table E
200 8" ANSI 16.5, BS PN10 20,7 59300W080AWS 59300W080AWSC √ √
200 – BS PN16 20,7 59300W086AWS 59300W086AWSC √ √
250 10" ANSI 16.5,BS PN10/16 12,1 59300W100AWS 59300W100AWSC √ √
300 12" ANSI 16.5,BS PN10/16 12,1 59300W120AWS 59300W120AWSC √ √

Model BFV-300 Wafer Style Butterfly Valve Without Internal Supervisory Switches
Accessory External Supervisory Switches And Mounting Brackets
Nominal
Part No.
Valve Size
Gear Bernstein
Operator Bernstein
Mounting Bernstein GC-SU1Z
Type I88-IP65
DN In Bracket with I88-IP65
LED Switch
Ex IP-66/67 ATEX
Mounting Bolts Regular Switch (Ex II2G Ex dIIC T6 Gb)
24V
Switch
50 - 100 2" - 4" 59300SPBRACKET10
Travelling Nut
125 - 150 5" - 6" 59300SPBRACKET20
59300SPSW 59300SPSWLED 59300SPSWATEX
200 8" 59300SPBRACKET25
Segmented Gear
250 - 300 10" - 12" 59300SPBRACKET30
Install a single switch in either bracket mounting position to monitor Open or Closed valve condition

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–8
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Shut Off Valves
BFV-300
Hydraulic Actuator, TruTorq

Sizes 2" thru 12" (DN50 thru DN300)

End Connection Wafer and Grooved

Tech Data Sheet Contact Tyco for details

TruTorq actuators are designed to combine the perfect balance of power, durability and safety, in a compact lightweight form.
• TruTorq actuators are compact Single Acting and Spring Return (SR) hydraulic actuators which are based on a double rack and
pinion design. • The actuators comply fully with all the relevant industry standards for interfaces and connections such as ISO
5211, DIN 337, VID/VDE 3845 and NAMUR. • Two types of actuators are recommended based on BFV sizes. The C-Type Actuator
is recommended for valve sizes 2” to 10”. The E-Type actuator is recommended for the 12” valves. • TruTorq C-Type and E-Type
actuators are hydraulic quarter turn actuators based on double rack and pinion design.

Model BFV-300 - Available Hydraulic Actuated Grooved Valves


Nominal
Pipe OD Grooved - Part No. Actuator
Valve Size
Description
DN In mm In Assembly Valve Actuator
DN50 2” 60,3 2.37 59300G020HACT 59300G020BS TSR8CNIHYDRFULL20 TSR 8 CNI FULL ASSY HYDRA ACT
DN65 2-1 ⁄ 2” 73,0 2.88 59300G025HACT 59300G025BS TSR8CNIHYDRFULL TSR 8 CNI FULL ASSY HYDRA ACT
DN65 2-1 ⁄ 2” 73,0 2.88 59300G026HACT 59300G026BS TSR8CNIHYDRFULL TSR 8 CNI FULL ASSY HYDRA ACT
DN80 3” 88,9 3.5 59300G030HACT 59300G030BS TSR8CNIHYDRFULL TSR 8 CNI FULL ASSY HYDRA ACT
DN100 4” 114,3 4.5 59300G040HACT 59300G040BS TSR8CNIHYDRFULL TSR 8 CNI FULL ASSY HYDRA ACT
DN125 5” 141,3 5.56 59300G050HACT 59300G050BS TSR20CNIHYDRFULL TSR 20 CNI FULL ASSY HYDRA ACT
DN125 5” 141,3 5.56 59300G056HACT 59300G056BS TSR20CNIHYDRFULL TSR 20 CNI FULL ASSY HYDRA ACT
DN150 6” 168,3 6.63 59300G060HACT 59300G060BS TSR35CNIHYDRFULL60 TSR 35 CNI FULL ASSY HYDRA ACT
DN200 8” 219,1 8.63 59300G080HACT 59300G080BS TSR35CNIHYDRFULL TSR 35 CNI FULL ASSY HYDRA ACT
DN250 10” 273 10.75 59300G100HACT 59300G100BS TSR35CNIHYDRFULL TSR 35 CNI FULL ASSY HYDRA ACT
DN300 12” 323,9 12.75 59300G120HACT 59300G120BS TSR70ECNIHYDRFULL TSR 70E CNI FULL ASSY HYDRA ACT

Model BFV-300 - Available Hydraulic Actuated Wafer Valves


Nominal
Pipe OD Wafer - Part No. Actuator
Valve Size
Description
DN In mm In Assembly Valve Actuator
DN50 2” 60,3 2.37 59300W020HACT 59300W020BS TSR8CNIHYDRFULL20 TSR 8 CNI FULL ASSY HYDRA ACT
DN65 2-1 ⁄ 2" 73,0 2.88 59300W025HACT 59300W025BS TSR8CNIHYDRFULL TSR 8 CNI FULL ASSY HYDRA ACT
DN80 3” 76,1 3.00 59300W030HACT 59300W030BS TSR8CNIHYDRFULL TSR 8 CNI FULL ASSY HYDRA ACT
DN80 3” 88,9 3.50 59300W036HACT 59300W036BS TSR8CNIHYDRFULL TSR 8 CNI FULL ASSY HYDRA ACT
DN100 4” 114,3 4.50 59300W040HACT 59300W040BS TSR8CNIHYDRFULL TSR 8 CNI FULL ASSY HYDRA ACT
DN125 5” 141,3 5.56 59300W050HACT 59300W050BS TSR20CNIHYDRFULL TSR 20 CNI FULL ASSY HYDRA ACT
DN150 6” 168,3 6.63 59300W060HACT 59300W060BS TSR35CNIHYDRFULL60 TSR 35 CNI FULL ASSY HYDRA ACT
DN200 8” 219,1 8.63 59300W080HACT 59300W080BS TSR35CNIHYDRFULL TSR 35 CNI FULL ASSY HYDRA ACT
DN200 8” 219,1 8.63 59300W086HACT 59300W086BS TSR35CNIHYDRFULL TSR 35 CNI FULL ASSY HYDRA ACT
DN250 10” 273,0 10.75 59300W100HACT 59300W100BS TSR35CNIHYDRFULL TSR 35 CNI FULL ASSY HYDRA ACT
DN300 12” 323,9 12.75 59300W120HACT 59300W120BS TSR70ECNIHYDRFULL TSR 70E CNI FULL ASSY HYDRA ACT

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–9
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Shut Off Valves


BFV-300 - Hydraulic Actuator, TruTorq

B A
BFV-300 Grooved with Hydraulic Actuator
Nominal
Pipe OD Dimension mm
Valve Size

C DN In mm In A B C D E
50 2" 60,3 2.37 200 162 109 124,5 306
65 2-1 ⁄ 2” 73,0 2.88 200 162 109 139,8 333,8
80 3" 88,9 3.50 200 162 109 146,3 346,3
E 100 4" 114,3 4.50 200 162 109 171,5 389,5
D 125 5" 141,3 5.56 231,5 218 140,5 201,5 473
150 6" 168,3 6.63 251 266 166,5 214,5 526
200 8" 219,1 8.63 251 266 166,5 236 572,5
250 10" 273,0 10.75 251 266 166,5 282 643,5
300 12" 323,9 12.75 286 340 211 310 762,5

B A
BFV-300 Wafer with Hydraulic Actuator
Nominal
Pipe OD Dimension mm
Valve Size
C DN In mm In A B C D E
50 2" 60,3 2.37 200 162 109 98 279,5
65 2-1 ⁄ 2” 73,0 2.88 200 162 109 113,3 307,3
80 3" 88,9 3.50 200 162 109 119,8 319,8
100 4" 114,3 4.50 200 162 109 145 363
E D
125 5" 141,3 5.56 231,5 218 140,5 166 437,5
150 6" 168,3 6.63 251 266 166,5 179 490,5
200 8" 219,1 8.63 251 266 166,5 204 540,5
250 10" 273,0 10.75 251 266 166,5 250 626,5
300 12" 323,9 12.75 286 340 211 278 730,5

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–10
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Shut Off Valves
BFV-300
Electric Actuator

Sizes 2" thru 12" (DN50 thru DN300)

End Connection Wafer and Grooved

Tech Data Sheet Contact Tyco for details

Bernard controls is the inventor of the compact quarter-turn electric actuator with 80+ years of continuous experience. • The
actuators are super compact in design. • The product architecture and torque range are adapted to customers requirement. • Three
different actuators AQ5, AQ10 and AQ25 are installed depending on the BFV size and 24V DC and 230V DC versions. • The actuators
features Integrated Control System (above). • They are 100% tested and delivered with short lead time.

Model BFV-300 - Available Electric Actuated Grooved Valves 230v


Nominal
Pipe OD Grooved - Part No. Actuator
Valve Size
Description
DN In mm In Assembly Valve Actuator
DN50 2” 60,3 2.37 59300G020E230 59300G020BS AQ5SWITCH16V230 AQ5 Electric Actuator Switch 230 V
DN65 2-1 ⁄ 2” 73,0 2.88 59300G025E230 59300G025BS AQ5SWITCH16V230 AQ5 Electric Actuator Switch 230 V
DN65 2-1 ⁄ 2” 73,0 2.88 59300G026E230 59300G026BS AQ5SWITCH16V230 AQ5 Electric Actuator Switch 230 V
DN80 3” 88,9 3.50 59300G030E230 59300G030BS AQ5SWITCH16V230 AQ5 Electric Actuator Switch 230 V
DN100 4” 114,3 4.50 59300G040E230 59300G040BS AQ5SWITCH16V230 AQ5 Electric Actuator Switch 230 V
DN125 5” 141,3 5.56 59300G050E230 59300G050BS AQ5SWITCH16V230 AQ5 Electric Actuator Switch 230 V
DN125 5” 141,3 5.56 59300G056E230 59300G056BS AQ5SWITCH16V230 AQ5 Electric Actuator Switch 230 V
DN150 6” 168,3 6.63 59300G060E230 59300G060BS AQ10SWITCH25V230 AQ10 Electric Actuator Switch 230 V
DN200 8” 219,1 8.63 59300G080E230 59300G080BS AQ10SWITCH25V230 AQ10 Electric Actuator Switch 230 V
DN250 10” 273,0 10.75 59300G100E230 59300G100BS AQ10SWITCH25V230 AQ10 Electric Actuator Switch 230 V
DN300 12” 323,9 12.75 59300G120E230 59300G120BS AQ25SWITCH30V230 AQ25 Electric Actuator Switch 230 V

Model BFV-300 - Available Electric Actuated Wafer Valves 230v


Nominal
Pipe OD Wafer - Part No. Actuator
Valve Size
Description
DN In mm In Assembly Valve Actuator
DN50 2” 60,3 2.37 59300W020E230 59300W020BS AQ5SWITCH16V230 AQ5 Electric Actuator Switch 230 V
DN65 2-1 ⁄ 2” 73,0 2.88 59300W025E230 59300W025BS AQ5SWITCH16V230 AQ5 Electric Actuator Switch 230 V
DN80 3” 88,9 3.50 59300W030E230 59300W030BS AQ5SWITCH16V230 AQ5 Electric Actuator Switch 230 V
DN80 3” 88,9 3.50 59300W036E230 59300W036BS AQ5SWITCH16V230 AQ5 Electric Actuator Switch 230 V
DN100 4” 114,3 4.50 59300W040E230 59300W040BS AQ5SWITCH16V230 AQ5 Electric Actuator Switch 230 V
DN125 5” 141,3 5.56 59300W050E230 59300W050BS AQ5SWITCH16V230 AQ5 Electric Actuator Switch 230 V
DN150 6” 168,3 6.63 59300W060E230 59300W060BS AQ10SWITCH25V230 AQ10 Electric Actuator Switch 230 V
DN200 8” 219,1 8.63 59300W080E230 59300W080BS AQ10SWITCH25V230 AQ10 Electric Actuator Switch 230 V
DN200 8” 219,1 8.63 59300W086E230 59300W086BS AQ10SWITCH25V230 AQ10 Electric Actuator Switch 230 V
DN250 10” 273,0 10.75 59300W100E230 59300W100BS AQ10SWITCH25V230 AQ10 Electric Actuator Switch 230 V
DN300 12” 323,9 12.75 59300W120E230 59300W120BS AQ25SWITCH30V230 AQ25 Electric Actuator Switch 230 V

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–11
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Shut Off Valves


BFV-300 - Electric Actuator

Model BFV-300 - Available Electric Actuated Grooved Valves 24v


Nominal
Pipe OD Grooved - Part No. Actuator
Valve Size
Description
DN In mm In Assembly Valve Actuator
DN50 2” 60,3 2.37" 59300G020E24 59300G020BS AQ5SWITCH13V24 AQ5 Electric Actuator Switch 24 VCC
DN65 2-1 ⁄ 2” 73,0 2.88" 59300G025E24 59300G025BS AQ5SWITCH13V24 AQ5 Electric Actuator Switch 24 VCC
DN65 2-1 ⁄ 2” 73,0 2.88" 59300G026E24 59300G026BS AQ5SWITCH13V24 AQ5 Electric Actuator Switch 24VCC
DN80 3” 88,9 3.50" 59300G030E24 59300G030BS AQ5SWITCH13V24 AQ5 Electric Actuator Switch 24 VCC
DN100 4” 114,3 4.50" 59300G040E24 59300G040BS AQ5SWITCH13V24 AQ5 Electric Actuator Switch 24 VCC
DN125 5” 141,3 5.56" 59300G050E24 59300G050BS AQ5SWITCH13V24 AQ5 Electric Actuator Switch 24 VCC
DN125 5” 141,3 5.56" 59300G056E24 59300G056BS AQ5SWITCH13V24 AQ5 Electric Actuator Switch 24VCC
DN150 6” 168,3 6.63" 59300G060E24 59300G060BS AQ10SWITCH21V24 AQ10 Electric Actuator Switch 24 VCC
DN200 8” 219,1 8.63" 59300G080E24 59300G080BS AQ10SWITCH21V24 AQ10 Electric Actuator Switch 24 VCC
DN250 10” 273,0 10.75" 59300G100E24 59300G100BS AQ10SWITCH21V24 AQ10 Electric Actuator Switch 24 VCC
DN300 12” 323,9 12.75" 59300G120E24 59300G120BS AQ25SWITCH25V24 AQ25 Electric Actuator Switch 24 VCC

Model BFV-300 - Available Electric Actuated Wafer Valves 24v


Nominal
Pipe OD Wafer - Part No. Actuator
Valve Size
Description
DN In mm In Assembly Valve Actuator
DN50 2” 60,3 2.37" 59300W020E24 59300W020BS AQ5SWITCH13V24 AQ5 Electric Actuator Switch 24 VCC
DN65 2-1 ⁄ 2” 73,0 2.88" 59300W025E24 59300W025BS AQ5SWITCH13V24 AQ5 Electric Actuator Switch 24 VCC
DN80 3” 88,9 3.5" 59300W030E24 59300W030BS AQ5SWITCH13V24 AQ5 Electric Actuator Switch 24 VCC
DN80 3” 88,9 3.5" 59300W036E24 59300W036BS AQ5SWITCH13V24 AQ5 Electric Actuator Switch 24 VCC
DN100 4” 114,3 4.5" 59300W040E24 59300W040BS AQ5SWITCH13V24 AQ5 Electric Actuator Switch 24 VCC
DN125 5” 141,3 5.56" 59300W050E24 59300W050BS AQ5SWITCH13V24 AQ5 Electric Actuator Switch 24 VCC
DN150 6” 168,3 6.63" 59300W060E24 59300W060BS AQ10SWITCH21V24 AQ10 Electric Actuator Switch 24 VCC
DN200 8” 219,1 8.63" 59300W080E24 59300W080BS AQ10SWITCH21V24 AQ10 Electric Actuator Switch 24 VCC
DN250 10” 273,0 10.75" 59300W100E24 59300W100BS AQ10SWITCH21V24 AQ10 Electric Actuator Switch 24 VCC
DN300 12” 323,9 12.75" 59300W120E24 59300W120BS AQ25SWITCH25V24 AQ25 Electric Actuator Switch 24 VCC

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–12
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Shut Off Valves
BFV-300 - Electric Actuator

B A BFV-300 Grooved with Electric Actuator


Nominal
Pipe OD Dimension mm
Valve Size
DN In mm In A B C D E F
50 2" 60,3 2.37 280 184 286 124,5 483,0 206,5
C
65 2-1 ⁄ 2” 73,0 2.88 280 184 286 139,8 510,8 221,8
80 3" 88,9 3.50 280 184 286 146,3 523,3 228,3
100 4" 114,3 4.50 280 184 286 171,5 566,5 253,5
E
125 5" 141,3 5.56 280 184 286 201,5 622,5 283,5
F
D 150 6" 168,3 6.63 280 184 286 214,5 618,5 296,5
200 8" 219,1 8.63 280 184 286 236 692,0 318
250 10" 273,0 10.75 280 184 286 282 767,0 364
300 12" 323,9 12.75 379 224 318 310 869,5 413

B A BFV-300 Wafer with Electric Actuator


Nominal
Pipe OD Dimension mm
Valve Size
DN In mm In A B C D E F
50 2" 60,3 2.37 280 184 286 98 456,5 180
C
65 2-1 ⁄ 2” 73,0 2.88 280 184 286 113,3 484,3 195,3
80 3" 88,9 3.50 280 184 286 119,8 496,8 201,8
100 4" 114,3 4.50 280 184 286 145 540 227
E
125 5" 141,3 5.56 280 184 286 166 583 248
F
D 150 6" 168,3 6.63 280 184 286 179 610 261
200 8" 219,1 8.63 280 184 286 204 660 286
250 10" 273,0 10.75 280 184 286 250 746 332
300 12" 323,9 12.75 379 224 318 278 837,5 381

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–13
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Shut Off Valves


Model Infinity / 05-47 Series Resilent Gate Valves
Non Rising Stem
Sizes DN50 thru DN400 (2" thru 16")

ISO, NF, KIWA, DVGW, WRAS, ÖVGW,


Approvals
GOST, FM, VdS

Maximum Working
16,0 bar (232 psi)
Pressure

End Connection Flange x Flange

Flange Drilling PN10/PN16

Tech Data Sheet Contact Tyco for details

Full and straight bore, so the flow is optimum with minimum head losses • Maintenance free • Tightness through the stem made
with three O-rings • Dust guard to protect the spindle from any impurities • 100% tested according to EN 12166-1 standard • New
wedge and stem technology ensures smooth functionality with outstanding low torque values • New guiding system for the wedge
with male composite sliding skate in order to easily achieve the 2500 cycles enurance test required by European standards.

Model Infinity - DN50 - DN300

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–14
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Shut Off Valves
Model Infinity / 05-47 Series Resilent Gate Valves - Dimensions

Model Infinity /05-47 Flange x Flange - DN50 - DN400


EN 5858
Weight kg
Part Number Size EN-1092-2 PN10 EN-1092-2 PN16 (DIN No. of
PN10/16
3203) H L B øD1 turns
F4 PN10/16 F5 PN10/16 S14 S15 mm mm mm mm for
øD øK øG no. øK øG no. S14 S15
or PN10 F4 PN16 or PN10 DN in. (F4) (F5) closing
mm mm mm X d mm mm X d (F4) (F5)
(>= 8") (>= 8") mm mm
594700608 - - 50 2" 165 125 99 4x19 125 99 4x19 150 250 185 83 - 150 14 8 9
594700768 - 594710768 65 2-1 ⁄ 2" 185 145 118 4x19 145 118 4x19 170 270 227 93 - 150 15 12 13
594700898 - 594710898 80 3" 200 160 132 8x19 160 132 8x19 180 280 250 100 - 200 18 14 15
594701148 - 594711148 100 4" 220 180 156 8x19 180 156 8x19 190 300 287 110 - 200 21,5 16 18
594701398 - 594711398 125 5" 250 210 184 8x19 210 184 8x19 200 325 324 125 - 300 27 23 25
594701688 - 594711688 150 6" 285 240 211 8x23 240 211 8x23 210 350 368 143 - 300 32 27 31
594702197 594702198 594712197 200 8" 340 295 266 8x23 295 266 12x23 230 400 450 170 - 400 41,5 47 54
594702737 594702738 - 250 10" 400 350 319 12x23 355 319 12x23 250 450 546 200 - 400 43 69 78,8
594703247 594703248 - 300 12" 455 400 370 12x23 410 370 12x23 270 500 621 228 - 500 51 97 115
594703557 - - 350 14" 520 460 429 16x23 470 429 16x28 290 550 812 260 506 600 51 190 213
594704067 - - 400 16" 580 515 480 16x28 525 480 16x31 310 600 905 290 606 800 58 274 311

Model Infinity - DN350 - DN400

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–15
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Shut Off Valves


Model Infinity / 05-47 Series Resilent Gate Valves - DN50 & DN300

Model Infinity 05-47 - DN350 & DN400


Item
Description Qty. Material
No.
1 Body 1 GJS 500/7, EN 1563
2 Bonnet 1 GJS 500/7, EN 1563
3 Wedge 1 GJS 500/7, EN 1563
4 Wedge Coating 1 EPDM, EN 681-1
X20 Cr13, EN 10088,
5 Stem 1
AISI 420
Copper Alloy, EN 12165,
6 Wedge Lock Nut 1
CW-617N
7 Body Bonnet Gasket 1 EPDM, EN 681-1
8 Stem Washer 1 POM
9 O-Ring (Stem) 1 EPDM, EN 681-1
Copper Alloy, EN 12165,
10 Stuffing Nut 1
CW307G
11 O-Ring (Stuffing Nut) 2 NBR, ASTM D2000
12 O-Ring (Bonnet) 1 NBR, ASTM D2000
Steel 12.9, DIN 912
as/
13 Body Bonnet Bolts Dimensions
DN
(GEOMET Coating)
14 Dust Guard 1 EPDM, EN 681-1
Stainless Steel, EN 10130,
15 Handwheel 1
DC04 (DIN 1.0388)
Stainless Steel, EN 10088,
16 Handwheel Bolt 1
(A4) DIN 933 Dimensions
Stainless Steel, EN 10088,
17 Handwheel Washer 1
(A4) DIN 9021 Dimensions
18 Square Cap 1 EN GJS 500/7, EN 1563
Stainless Steel, EN 10088,
19 Square Cap Bolt 1
(A4) DIN 912 M4
20 Tape Square 1 LUPOLEN
21 Wedge Guide 2 Fortron+40%GF
22 Locking Device 3 PA6+50%GF
23 Indicator Carcase 1 AISI, Aluminium
Copper Alloy, EN 12165,
24 Indicator Cradle 1
CW617N
25 Ind. Carcase Dustguard 1 EPDN, EN 681-1
Stainless Steel, EN 10088,
26 Thread Stick 2 (A4) M8x10 DN-40-50,
M8x8 DN>50

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–16
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Shut Off Valves
Model Infinity / 05-47 Series Resilent Gate Valves - DN350 & DN400

Model Infinity 05-47 - DN350 & DN400


Item
Description Qty. Material
No.
1 Body 1 GJS 500/7, EN 1563
2 Bonnet 1 GJS 500/7, EN 1563
3 Wedge 1 GJS 500/7, EN 1563
4 Wedge Coating 1 EPDM, EN 681-1, W270
5 Stem 1 X20Cr13, EN 10088, AISI 420
Copper Alloy, EN 12165,
6 Wedge Lock Nut 1
CW-617N
7 Body Bonnet Gasket 1 EPDM, EN 681-1
8 Lower Packing Bushing 1 POM, Acetal Resin
9 O-Ring (Stem) 2 EPDM, EN 681-1
10 Upper Packing Bushing 1 POM, Acetal Resin
O-Ring Int.
11 2 NBR, ASTM D2000
(Upper Packing)
O-Ring Ext.
12 1 NBR, ASTM D2000
(Upper Packing)
Steel 9.122, EN 10088,
13 Body Bonnet Bolt 10
DIN 912 (Rech. Geomet)
14 Dust Guard 1 EPDM, EN 681-1
15 Handweel 1 Stamped Steel
AISI 316, EN 10088,
16 Handweel Bolt 1
(A4) DIN 933
AISI 316, EN 10088,
17 Handweel Washer 1
(A4) DIN 9021
18 Wedge Guides 2 PPS + 4-%GF
19 Upper Bonnet 1 GJS 500/7, EN 1563
20 O-Ring (Lower Packing) 1 EPDM, EN 681-1
21 Axial Bering Roller 2 Steel
O-Ring Bonnet-Jpper
22 1 NBR, ASTM D2000
Bonnet
Bonnet-Upper AISI 316, EN 10088,
23 3
Bonnet Bolt (A4) DIN 912
AISI 316, EN 10088,
24 Eyebolt 2
(A4) DIN 580
AISI 316, EN 10088,
25 Cotter 1
(A4) DIN 6885
26 Washer Upper Packing 1 254 SMO, DIN 1.4547
27 Indicator Plate 1 1 - 114, DIN 36011
AISI 316, EN 10088,
28 Indicator Plate Bolt 1
(A4) DIN 933
29 Indicator Wedge 1 Bronze Rg. 5, DIN 1705
30 Indicator Stem 1 AISI 304, EN 10088, A2

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–17
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Shut Off Valves


Model TJR Series Resilient-Seated Gate Valves

Outside Screw and Yoke

Sizes DN50 thru DN400 (2" thru 16")

Approvals UL & C-UL Listed & FM Approved

Maximum Working UL - 20,7 bar (300 psi) up to DN300 (12")


Pressure FM - 16,0 bar (232 psi) up to DN300 (12")

End Connection Flange x Flange, Flange x Groove, Groove x Groove

Flange Drilling ANSI, PN, AS

Tech Data Sheet TFP1541

TYCO TJ Series Resilient-Seated Gate Valves are offered in multiple end connection configurations including: Flange by Flange,
Flange by Groove, and Groove by Groove • Tapping bossed for up and downstream connection to valve trims • Ductile iron wedge
gate, fully encapsulated with EPDM rubber • Corrosion-resistant components

Parts List
Item
Description Qty. Material
No.
19 10 1 Body 1 ASTM A536 65-45-12
2 Wedge 1 EPDM
11 17 3 Stem 1 AISI SS240
4 Bonnet 1 ASTM A536 65-45-12
9 16 5 Disc Nut 1 ASTM A351 CF8
6 Packing 1 ASTM A536 65-45-12
8 18 7 Nut 1 ASTM B62
8 Nut Shim 1 ASTM B16
7 6 9 Handwheel Shim 1 ASTM B16
10 Handwheel 1 ASTM A536 65-45-12
3 4 11 Handwheel Nut 1 Carbon Steel Galvinized
12 Packing 3 PTFE
12 13 13 Seal Ring 1 EPDM
14 Hexagonal Screw 4-10 8.8 Rating
14 1 15 O-Ring 1 EPDM
16 Hexagonal Nut 2 ASTM SS304
15 20 17 Bolt 2 ASTM SS304
18 Spring Washer 2 ASTM SS304
5 19 Cylindrical Screw 1 ASTM SS304
20 Plug 2 ASTM SS304
2

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–18
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Shut Off Valves
Model TJR Series Resilient-Seated Gate Valves - Flange x Flange

Model TJR - Flange x Flange


P Nominal Approval &
Part Number Size O.D. Size Dimensions mm
Tapping Handwheel Listings
Flange x Flange x Flange x Boss Turns to Fully Weight
Flange Flange Flange Size Operate kg UL/
DN in. mm in. L CL1 CL2 FM
ISO 7005-2 ANSI AS 2129 ANSI (Open or C-UL
PN16 Class 150 (Table E) NPT close)
TJRX0500001 TJRX0500003 TJRX0500005 50 2" 60,3 2.375 178 395 332 13 17,64 √ √
TJRX0650001 TJRX0650003 TJRX0650005 65 2-1 ⁄ 2" 73,0 2.875 190 410 338 16 18,91 √ √
- - 65 76,1mm 76,1 3.000 190 410 338 16 18,91 √ √
TJRX0800001 TJRX0800003 TJRX0800005 80 3" 88,9 3.500 203 480 380 1
⁄ 2" 20 22,13 √ √
TJRX1000001 TJRX1000003 TJRX1000005 100 4" 114,3 4.500 229 573 450 20 27,16 √ √
- - 150 165,1mm 165,1 6.500 254 750 592 25 46,9 √ √
TJRX1500001 TJRX1500003 TJRX1500005 150 6" 168,3 6.625 267 750 592 25 46,9 √ √
3
TJRX2000001 TJRX2000003 TJRX2000005 200 8" 219,1 8.625 292 956 748 ⁄4 " 34 72,0 √ √
TJRX2500001 TJRX2500003 TJRX2500005 250 10" 273,1 10.750 330 1175 888 42 111,0 √ √
TJRX3000001 TJRX3000003 TJRX3000005 300 12" 323,9 12.750 356 1318 1005 50 167,0 √ √
1"
TJRX3500001 - TJRX3500005 350 14" 355,6 14.014 381 1205 1577 20 287,0 √ √
TJRX4000001 - TJRX4000005 400 16" 406,4 16.000 406 1383 1800 20 376,0 √ √

OPEN

SHUT

CL1

CL2

L
FLANGE x FLANGE

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–19
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Shut Off Valves


Model TJR Series Resilient-Seated Gate Valves - Flange x Groove

Model TJR - Flange x Groove


Approval &
Part Number Size O.D. Size Dimensions mm Nominal
P Listings
Handwheel
Flange x Flange x Tapping Weight
Turns to Fully
Groove Groove Boss Size kg UL/
DN in. mm in. L CL1 CL2 Operate FM
ISO 7005-2 ANSI ANSI NPT C-UL
(Open or close)
PN16 Class 150
TJRT0500601 TJRT0500603 50 2" 60,3 2.375 178 395 332 13 16,7 √ √
TJRT0650731 TJRT0650733 65 2-1 ⁄ 2" 73,0 2.875 190 410 338 16 17,8 √ √
TJRT0650761 TJRT0650763 65 76,1mm 76,1 3.000 190 410 338 16 17,8 √ √
TJRT0800891 TJRT0800893 80 3" 88,9 3.500 203 480 380 1
⁄ 2" 20 22,0 √ √
TJRT1001141 TJRT1001143 100 4" 114,3 4.500 229 573 450 20 25,6 √ √
TJRT1501651 TJRT1501653 150 165,1mm 165,1 6.500 254 750 592 25 45,0 √ √
TJRT1501681 TJRT1501683 150 6" 168,3 6.625 267 750 592 25 45,0 √ √
3
TJRT2002191 TJRT2002193 200 8" 219,1 8.625 292 956 748 ⁄4 " 34 73,0 √ √
TJRT2502731 TJRT2502733 250 10" 273,1 10.750 330 1175 888 42 108,5 √ √
1"
TJRT3003241 TJRT3003243 300 12" 323,9 12.750 356 1318 1005 50 163,5 √ √

OPEN

SHUT

CL1

CL2

L
FLANGE x GROOVE

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–20
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Shut Off Valves
Model TJR Series Resilient-Seated Gate Valves - Groove x Groove

Model TJR - Flange x Flange


Nominal Approval
Part Number Size O.D. Size Dimensions mm P
Handwheel & Listings
Tapping Weight
Turns to Fully
Groove x Boss Size kg UL/
DN in. mm in. L CL1 CL2 Operate FM
Groove ANSI NPT C-UL
(Open or close)
TJRG0500604 50 2" 60,3 2.375 178 395 332 13 15,8 √ √
TJRG0650734 65 2-1 ⁄ 2" 73,0 2.875 190 410 338 16 16,6 √ √
TJRG0650764 65 76,1mm 76,1 3.000 190 410 338 16 16,6 √ √
TJRG0800894 80 3" 88,9 3.500 203 480 380 1
⁄ 2" 20 21,8 √ √
TJRG1001144 100 4" 114,3 4.500 229 573 450 20 24,0 √ √
TJRG1501654 150 165,1mm 165,1 6.500 254 750 592 25 43,0 √ √
TJRG1501684 150 6" 168,3 6.625 267 750 592 25 43,0 √ √
3
TJRG2002194 200 8" 219,1 8.625 292 956 748 ⁄4 " 34 74,0 √ √
TJRG2502734 250 10" 273,1 10.750 330 1175 888 42 106,0 √ √
1"
TJRG3003244 300 12" 323,9 12.750 356 1318 1005 50 160,0 √ √

OPEN

SHUT

CL1

CL2

P L
GROOVE x GROOVE

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–21
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Shut Off Valves


Model TJP Series Resilient-Seated Gate Valves

Non-Rising Stem

Sizes DN50 thru DN600 (2" thru 24")

Approvals UL & C-UL Listed & FM Approved

Maximum Working UL - 20,7 bar (300 psi)


Pressure FM - 16,0 bar (232 psi)

End Connection Flange x Flange, Flange x Groove, Groove x Groove

Flange Drilling ANSI & ISO

Tech Data Sheet TFP1546

TYCO TJ Series Resilient-Seated Gate Valves are offered in multiple end connection configurations including: Flange by
Flange, Flange by Groove, and Groove by Groove • Ductile iron wedge gate, fully encapsulated with EPDM rubber • Corrosion-
resistant components

Parts List
Item
14 12 Description Qty. Material
No.
1 Body 1 ASTM A536 65-45-12
13 9 2 Wedge 1 EPDM
3 Stem 1 AISI SS240
10 11
4 Bonnet 1 ASTM A536 65-45-12
5 Half-Ring 1 ASTM C1100
6 8
6 Seal Seat 1 ASTM A536 65-45-12
19 18 7 Disc Nut 1 ASTM B62 C83600
8 Seal Ring 1 EPDM
21 5 9 O-Ring 2 EPDM
10 Dust Ca 1 EPDM
20 4 11 Hex Socket Cap Screw 2 8.8 Rating
12 Wench Nut 1 ASTM A536 65-45-12
17 16 13 Washer 1 ASTM SS304
14 Hex Socket Cap Screw 1 8.8 Rating
3 1 15 Plug 2 ASTM SS304
16 Gasket 1 EPDM
7 15 17 Hex Socket Cap Screw 4-10 ASTM SS304
18 Post Flange 1 ASTM A536 65-45-12
2 19 Washer 2 Carbon Steel Galvanized
20 Spring Washer 2 Carbon Steel Galvanized
21 Hex Socket Cap Screw 2 8.8 Rating

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–22
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Shut Off Valves
Model TJP Series Resilient-Seated Gate Valves - Flange x Flange

Model TJP - Flange x Flange


P Approval &
Part Number Size O.D. Size Dimensions mm
Tapping Listings
Boss Weight
Flange x Flange Flange x Flange Flange x Flange
Size kg UL/
ISO 7005-2 ANSI AS 2129 DN in. mm in. L CL FM
ANSI C-UL
PN16 Class 150 (Table E)
NPT
TJPX1000001 TJPX0800003 TJPX0800005 50 2" 60,3 2.375 178 579 11,3 √ √
TJPX1000001 TJPX1000003 TJPX1000005 100 4" 114,3 4.500 229 332 1
⁄ 2" 35 √ √
TJPX1500001 TJPX1500003 TJPX1500005 150 6" 168,3 6.625 267 436 50 √ √
3
TJPX2000001 TJPX2000003 TJPX2000005 200 8" 219,1 8.625 292 520 ⁄4 " 83 √ √
TJPX2500001 TJPX2500003 TJPX2500005 250 10" 273,1 10.750 330 620 123,5 √ √
TJPX3000001 TJPX3000003 TJPX3000005 300 12" 323,9 12.750 356 670 175,5 √ √
TJPX3500001 TJPX3500003 TJPX3500005 350 14" 355,6 14.000 381 862 230 √ √
TJPX4000001 TJPX4000003 TJPX4000005 400 16" 406,4 16.000 406 938 1" 324 √ √
TJPX4500001 TJPX4500003 TJPX4500005 450 18" 457,2 18.000 432 1057 440 √ √
TJPX5000001 TJPX5000003 TJPX5000005 500 20" 508,0 20.000 457 1142 638 √ √
TJPX6000001 TJPX6000003 TJPX6000005 600 24" 609,6 24.000 508 1295 820 √ √

CL

L
FLANGE x FLANGE

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–23
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Shut Off Valves


Model TJP Series Resilient-Seated Gate Valves - Flange x Groove

Model TJP - Flange x Groove


Part Number Size O.D. Size Dimensions mm P Approval & Listings
Tapping
Flange x Flange x
Boss Weight
Groove Groove UL/
DN in. mm in. L CL Size kg FM
ISO 7005-2 ANSI C-UL
ANSI
PN16 Class 150
NPT
TJPT0500601 TJPT0500603 50 2" 60,3 2.375 178 579 10,9 √ √
TJPT1001141 TJPT1001143 100 4" 114,3 4.500 229 332 1
⁄ 2" 33,4 √ √
TJPT1501681 TJPT1501683 150 6" 168,3 6.625 267 436 48,0 √ √
3
TJPT2002191 TJPT2002193 200 8" 219,1 8.625 292 520 ⁄4 " 84,0 √ √
TJPT2502731 TJPT2502733 250 10" 273,1 10.750 330 620 121,0 √ √
1"
TJPT3003241 TJPT3003243 300 12" 323,9 12.750 356 670 172,0 √ √

CL

L
FLANGE x GROOVE

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–24
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Shut Off Valves
Model TJP Series Resilient-Seated Gate Valves - Groove x Groove

Model TJP - Groove x Groove


Part Number Size O.D. Size Dimensions mm P Approval & Listings
Tapping
Boss Weight
Groove x UL/
DN in. mm in. L CL Size kg FM
Groove C-UL
ANSI
NPT
TJPX0500604 50 2" 60,3 2.375 178 579 10,5 √ √
TJPX1001144 100 4" 114,3 4.500 229 332 1
⁄ 2" 23,1 √ √
TJPX1501684 150 6" 168,3 6.625 267 436 46,1 √ √
3
TJPX2002194 200 8" 219,1 8.625 292 520 ⁄4 " 85,0 √ √
TJPX2502734 250 10" 273,1 10.750 330 620 118,5 √ √
1"
TJPX3003244 300 12" 323,9 12.750 356 670 168,5 √ √

CL

L
GROOVE x GROOVE

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–25
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Shut Off Valves


Model TJP Series Resilient

Vertical Indicator Post

Sizes DN50 thru DN400 (2" thru 16")

Approvals UL & C-UL Listed & FM Approved

Maximum Working UL - 20,7 bar (300 psi)


Pressure FM - 16,0 bar (232 psi)

Tech Data Sheet TFP1546

Indicators provide external visual indication of the open or shut valve condition
as well as a locking mechanism to secure a particular wedge position.

2 Parts List
3 Item
25
24 Description Qty. Material
5 No.
1
13 1 Locking Wrench 1 ASTM A126B
4
26 2 Operating Nut 1 ASTM B62
23
6 3 Hex Cap Screw 2 ASTM A105
7 4 Hex Nut 2 ASTM A105
5 Snap Ring 1 AISI 066
8 6 Target Carrier Yoke 1 ASTM B62
9 7 Target 4 ASTM B108
8 Hex Cap Screw 4 ASTM A105
10
9 Window Glass 2 Lexan-UN
12 10 Window Glass Gasket 2 PTFE
11
11 Hex Cap Screw 4 ASTM A105
12 Hex Nut 4 ASTM A105
13 Upper Post 1 ASTM A536
14 Hex Cap Screw 6 ASTM A105
15 Hex Nut 6 ASTM A105
16 Mounting Flange 1 ASTM A126B
BURY LINE 17 Hex Cap Screw 4 ASTM A105
18 Hex Nut 4 ASTM A105
Connection Tube
19 1 ASTM A536
Coupling
14 20 Cotter Pin 1 AISI 304
15 21 Inner Pipe 1 ASTM A53
22
22 Connection Tube 1 AISI 1045
21 23 Plug 1 AISI 304
24 Cap 1 ASTM A126B
25 Phillips Head Screw 1 AISI 304
26 Lock Hasp 1 ASTM 307B
16
20
19
18
17

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–26
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Shut Off Valves
Model TJP Series Resilient-Seated Gate Valves - Vertical Indicator Post

Model TJP - Vertical Indicator Post


SUPERVISORY
A
B SWITCH
Valve CL to Dimensions Approval &
(NOT INCLUDED) Part Size
Finished mm Listings
Number
Grade
INDICATOR DN In. Min. Max. B C UL FM
WINDOW 50 2" 744 1614 √ √
100 4" 791 1661 √ √
WRENCH LOCK TJUPA 150 6" 892 1762 √ √
(NOT INCLUDED) 240
Type A 200 8" 975 1845 √ √
250 10" 1075 1945 √ √
WRENCH 300 12" 1156 2026 760 √ √
350 14" 1292 4022 √ √
UPPER POST 400 16" 1367 4097 √ √
C TJUPB
450 18" 1487 4217 287 √ √
Type B
INDICATOR 500 20" 1572 4302 √ √
MARK RING 600 24" 1724 4454 √ √
* Type B Post bottom flange features reducing gear for compatibility
FINISHED with DN350 (14") and larger valve sizes.
GRADE LINE

OUTER POST

INNER PIPE

BOTTOM
FLANGE*
A
MOUNTING
BOLTS AND
NUTS

GATE VALVE
INDICATOR
MATING
FLANGE

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–27
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Shut Off Valves


Model TJP Series Resilient - Cross Wall Indicator Post

Cross Wall Indicator Post

Sizes DN50 thru DN300 (2" thru 12")

Approvals UL & C-UL Listed & FM Approved

Maximum Working UL - 20,7 bar (300 psi)


Pressure FM - 16,0 bar (232 psi)

Tech Data Sheet TFP1546

Indicators provide external visual indication of the open or shut valve condition as well as a locking mechanism to secure a
particular wedge position.

Parts List
21 16 22 5 4 1
Item
Description Qty. Material
No.
1 Lifting Eye Bolt 1 ASTM A307B
2 Hex Nut 1 ASTM A307B
3 Washer 1 ASTM A307B
4 Handwheel 1 ASTM A536
5 Operating Nut 1 ASTM B62
6 Hex Cap Screw 2 ASTM A307B
7 Hex Nut 2 ASTM A307B
8 Snap Ring 1 AISI 066
Target Carrier
9 1 ASTM B62
24 23 3 2 Yoke
10 Target 4 ASTM B108
11 Hex Cap Screw 4 ASTM A307B
12 Window Glass 2 Lexan-UN
14 13 12 11 10 Window Glass
13 2 PTFE
Gasket
14 Hex Cap Screw 4 ASTM A307B
15 Hex Nut 4 ASTM A307B
16 Body 1 ASTM A536
17 Stand Pipe 1 ASTM A53
18 Connection Tube 1 AISI 1045
19 Cotter Pin 1 AISI 304
Connection Tube
20 1 ASTM A536
Coupling
21 Plug 1 Malleable Iron
22 Cap 1 ASTM A126B
20 19 18 17 15 9 7 8 6
Phillips Head
23 1 AISI 304
Screw
24 Lock Hasp 1 ASTM 307B

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–28
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Shut Off Valves
Model TJP Series Resilient - Cross Wall Indicator Post

Model TJP - Cross Wall Indicator Post


A
Approval &
Size Valve CL to
Part Number Listings
Exterior Wall
DN In. Min. Max. UL FM
50 2" 273 2500 √ √
100 4" 325 2550 √ √
150 6" 422 2647 √ √
TJWP
200 8" 513 2738 √ √
250 10" 615 2840 √ √
300 12" 700 2925 √ √

514 mm
A
(20-1/4")

320 mm
ANCHORING
(12-5/8")
HARDWARE
(NOT INCLUDED) WALL
SUPERVISORY
267 mm SWITCH
(10-1/2") (NOT INCLUDED)
GATE
SQUARE
GATE VALVE INDICATOR
SPACED
VALVE TOP CAP BODY
CONNECTION
COUPLING

375 mm
(14-3/4") DIA.

SQUARE
CONNECTION
TUBE
SYSTEM PIPE
AND CONNECTING HANDWHEEL
HARDWARE STANDPIPE HANDWHEEL
(NOT INCLUDED) 114,3 mm LOCK AND CHAIN TARGET
(4-1/2") O.D. (NOT INCLUDED) WINDOW

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–29
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Shut Off Valves


Model 4908

Shut-Off Valve, Road Box Adjustable

Tech Data Sheet Contact Tyco for details

Model 4908 Shut-Off Valve


Part No. Dimensions mm
Weight
Top Bottom
A B C F kg
Section Section
54-S 61-S 457-610 267 381 165 26,8
55-S 61-S 584-737 394 381 165 31,5
55-S 62-S 610-914 394 648 165 36,1
55-S 64-S 914-1219 394 914 216 44,0
56-S 62-S 965-1219 673 648 165 41,1
56-S 64-S 914-1524 673 914 216 52,0

T-Type Wrench
A Weight
Part No.
mm kg
5050 1220-2440 9

2”

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–30
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Shut Off Valves
Model 1610

Shut-Off Valve, Ball Valve

Approvals CE, UL, & FM

Maximum Service
27,6 bar (400 PSI)
Pressure

Tech Data Sheet Contact Tyco for details

Model 1610 Ball Valve Full Bore


Size PN Dimensions mm Weight Approval & Listings
Part Number Kv
DN BSP [Bar] I L H CH R h kg CE UL FM
1
1610000130 8 ⁄4 ” 64 11 52 23 20 95 48 5,4 0,14 √ √ √
3
1610000170 10 ⁄ 8” 64 11 52 23 20 95 48 6 0,13 √ √ √
1
1610000210 15 ⁄ 2” 30 15 59 30 25 96 48 16 0,17 √ √ √
3
1610000270 20 ⁄4 ” 30 16 67 36 31 121 57 30 0,29 √ √ √
1610000340 25 1” 30 19 82 44 38 121 59 43 0,44 √ √ √
1610000420 32 1-1 ⁄4” 25 22 94 53 48 151 73 89 0,76 √ √ √
1610000480 40 1-1 ⁄ 2” 25 22 103 65 54 151 79 230 1,02 √ √ √
1610000600 50 2” 25 26 123 80 67 170 94 265 1,75 √ √ √

R
Ball Valve with Locking Device
Part Number DN Weight
1
1610LD210 15 ⁄ 2” BSP 0,37
3 ch
1610LD270 20 ⁄4” BSP 0,49 h
1610LD340 25 1” BSP 0,64
1610LD420 32 1-1 ⁄4” BSP 0,96
1610LD480 40 1-1 ⁄ 2” BSP 1,22 DN
ØH
1610LD600 50 2” BSP 1,95
Temperature Range -20°C until +130°C, only suitable for water
and pressurized air. No gas.
I
L
8 9

7 Parts List
Item No. Description Material
1 Body Brass, Nickel Plated
6 2 End Connection Brass, Nickel Plated
5 3 Ball Brass, Nickel Plated
4 Ball Seat PTFE
5 Antifriction Seat PTFE
6 O-ring NBR
3 7 Nut Steel, Nickel Plated
8 Stem Steel, Zinc Plated
2 4 9 Handle Steel, Zinc Plated and Plastic Cover
1

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–31
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Shut Off Valves


Model 601

Shut-Off Valve, Ball Valve Stainless Steel Type 316

Maximum Service
40 bar (580 psi)
Pressure

Seat PFTE

Tech Data Sheet Contact Tyco for details

MODEL 601
PN L Weight
Part No. Dn Cv
[Bar] mm kg
1
708S00210 15 ⁄ 2” BSP 40 56 7 0,4
3
708S00270 20 ⁄4” BSP 40 58 9 0,8
708S00340 25 1” BSP 40 78 16 1,5
708S00420 32 1-1 ⁄4” BSP 40 77 24 1,8
708S00480 40 1-1 ⁄ 2” BSP 40 82 37 2,0
708S00600 50 2” BSP 40 99 68 2,5

Model 126S

Shut-Off Valve, Angle Valve

Approvals UL

Maximum Service
14 bar (203 psi)
Pressure

Seat Buna-N

Tech Data Sheet Contact Tyco for details

MODEL 126S Shut-Off Angle Valve


PN H Weight Approval & Listings
Part No. Dn
[Bar] mm kg UL
1
126S00210D 15 ⁄ 2” BSP 14 79,4 0,3
3
126S00270D 20 ⁄4” BSP 14 82,6 0,5
126S00340D 25 1” BSP 14 91,3 0,9
126S00420D 32 1-1 ⁄4” BSP 14 114,3 1,2
126S00480D 40 1-1 ⁄ 2” BSP 14 133,4 1,5
126S00600D 50 2” BSP 14 142,8 2,4 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–32
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Check Valves
CV-1F

Grooved Check Valve


Sizes 2" thru 10" (DN50 thru DN250)

UL, C-UL Listed & FM & VdS Approved


Approvals Compliance with CE Pressure Equipment Directive
(PED) and Standards of Engineering Practice

Maximum Working UL/FM - 20,7 bar (300 psi)


Pressure VdS - 16 bar (232psi)

End Connection Groove x Groove, Flange x Flange, Flange x Groove

Tech Data Sheet TFP1550

Can be installed either vertically or horizontally • Cut groove inlet and outlet connections • Suitable for use with grooved pipe
couplings that are listed or approved for fire protection service

Valve Material Specifications 4,16 18 17


Item 2 SEE
Description Material Qty. VIEW A
No.
3
1 Body Ductile Iron 1
2 Cap Ductile Iron 1
3 Gasket Synthetic Fibre 1 SEE
DETAIL B
4 Hex Cap Screw Steel, Zinc Plated AR
5 Clapper Stainless Steel or Ductile 1
Iron
1 15
6 Seal Facing EPDM Grade “E” 1
7 Spring Stainless Steel 1
8 Hinge Shaft Stainless Steel 1 8 8
9 Retaining Ring Stainless Steel AR 9 5
10 Washer Teflon 2 2 DN65-DN200 7 9 DN250 7
2 (10") 5
(2-1/2" - 8")
11 Retention Bolt Stainless Steel 1 VIEW A
13
12 Seal Ring Neoprene 1 5 13
11,16
13 Retaining Disc Stainless Steel 1 11 14,16
19
14 Locknut Stainless Steel 1 12 6
5 6
15 Plug-1⁄2"-14 NPT Cast Iron 2 DN65-DN200 DN250
(2-1/2" - 8") (10")
16 Adhesive Thread Sealer AR DETAIL B
17 Nameplate Aluminium 1
18 Rivet Steel 2
19 Spacer Stainless Steel 1

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–33
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Check Valves


CV-1F Grooved Check Valve

B A

O.D.

1/2"
NPT
1/2" J
NPT
E
F

Pipe Size Dimensions mm Approx. Approval & Listings


Part
Weight
Number Nom. O.D. A B C D E F J VdS UL FM T/S/U
kg
595900020 50 60.3 171,5 111,3 64,8 65,3 82,3 120,7 41,5 4,1 √ √ √ √
595900025 65 73.0 203,2 147,3 86,6 86,4 98,6 152,4 43,2 4,5 √ √ √ √
595900076 65 76,1 203,2 147,3 86,6 86,4 98,6 152,4 43,2 4,5 √ √ √ √
595900030 80 88,9 212,6 146,3 91,4 86,4 98,6 152,4 43,2 5,0 √ √ √ √
595900040 100 114,3 245,6 171,2 117,1 92,2 115,1 181,1 46,7 11,3 √ √ √ √
595900139 125 139,7 266,7 190,5 134,4 106,7 124,5 193,0 48,3 13,2 √ √ √ √
595900050 125 141,3 266,7 190,5 134,4 106,7 124,5 193,0 48,3 13,2 √ √ √ √
595900165 150 165,1 292,1 204,4 146,1 114,3 127,0 193,0 37,6 21,3 √ √ √ √
595900060 150 168,3 292,1 204,4 146,1 114,3 127,0 193,0 37,6 21,3 √ √ √ √
595900080 200 219,1 355,6 260,4 196,9 142,7 138,4 213,4 58,9 29,9 √ √ √ √
595900100 250 273,0 457,2 330,2 259,3 162,1 190,5 266,7 76,2 49,4 √ √ √ √
595900120 300 323,9 533,4 362,7 287,2 7,26 193,5 269,7 69,9 68,0 √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–34
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Check Valves
CV-1FR

Grooved-End Riser Check Valve


Sizes 2" thru 12" (DN50 thru DN300)

Approvals UL, C-UL Listed & FM Approved

Maximum Working
20,7 bar (300 psi)
Pressure

End Connection Groove x Groove

Tech Data Sheet TFP950

The TYCO Model CV-1FR Grooved-End Riser Check Valve is a compact and rugged swing-type unit that allows water flow in one
direction and prevents flow in the opposite direction.

Valve Material Specifications 4,15 17 16


Item 2 SEE
Description Material Qty.
No. VIEW A
1 Body Ductile Iron 1 3

2 Cover Ductile Iron 1


3 Cover Gasket Nitrile Rubber 1
Steel,
4 Hex Cap Screw AR
Zinc Plated
Clapper 2" - 8" SEE
Stainless Steel 1 DETAIL B
(DN50-200)
5
Clapper 10" - 12" 1
Ductile Iron 1
(DN250-300)
6 Clapper Facing EPDM Grade “E” 1
8 8
7 Spring Stainless Steel 1
9 5
8 Hinge Shaft Stainless Steel 1
2 7 9
9 Retaining Ring Stainless Steel AR 2 7 5
11 Retention Bolt Stainless Steel 1 DN50-DN200 DN250 - DN300
(2" - 8") (10" - 12")
13 Retaining Disc Stainless Steel 1 VIEW A

14 Locknut Stainless Steel 1


13
15 Adhesive Thread Sealer AR 5 13
11,15
16 Nameplate Aluminium 1 11 14,15
17 Rivet Steel 2 18
6
18 Spacer Stainless Steel 1 5 6
DN50-DN200 DN250 - DN300
(2" - 8") (10" - 12")
DETAIL B

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–35
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Check Valves


CV-1FR - Grooved-End Riser Check Valve

Pipe Size Dimensions mm Approx. Approval & Listings


Part
Weight Fire Academy
Number Nom. O.D. A B C D E UL FM
kg of Russia
595901020 50 60.3 171,5 149,1 82,6 241,9 1" 4.5 √ √ √
595901025 65 73.0 203,2 169,2 98,3 274,3 1-1 ⁄4" 4.5 √ √ √
595901076 65 76,1 203,2 169,2 98,3 274,3 1-1 ⁄4" 4.5 √ √ √
595901030 80 88,9 212,6 174,8 98,3 279,9 1-1 ⁄4" 5.0 √ √ √
595901040 100 114,3 244,6 193,7 115,1 302,7 2" 11.3 √ √ √
595901139 125 139,7 266,7 206,4 124,5 315,4 2" 13.2 √ √ √
595901050 125 141,3 266,7 206,4 124,5 315,4 2" 13.2 √ √ √
595901165 150 165,1 292,1 215,8 127,0 324,8 2" 21.3 √ √ √
595901060 150 168,3 292,1 215,8 127,0 324,8 2" 21.3 √ √ √
595901080 200 219,1 355,6 241,7 138,7 350,7 2" 30.0 √ √ √
595901100 250 273,0 457,2 264,3 190,5 373,3 2" 49.4 √ √ √
595901120 300 323,9 533,4 286,1 193,5 395,2 2" 68.0 √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–36
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Check Valves
Model TJCV

Swing Type Flanged Check Valve

Sizes DN50 - DN300 (2” - 12")

UL/ULC Listed & FM Approved,


Approvals
Conforms to AWWA C508

Maximum Working
20,7 bar (300 psi)
Pressure

End Connection Flanged ANSI Clas 125 / PN16

Tech Data Sheet TFP1563

The TYCO Model TJCV Check Valve Swing Type Flange End is a compact and rugged swing type unit that allows water flow in one
direction and pre-vents flow in the opposite direction • The valve is designed to minimize water hammer caused by flow reversal •
Installation can be in a horizontal position (with cover in the upward position), or vertical position (upward flow only) • A resilient
elastomer seal ensures a leak-tight seal and non-sticking operation • Removable cover for ease of field maintenance

Model TJCV Swing Type Flanged Check Valve L


Part No. Dimensions mm Weight Approval & Listings
DN
ANSI 125 PN16 H L kg UL FM
595902021 595902020 50 2” 117 203 √ √
595902026 595902025 65 2-1 ⁄ 2” 128 254 √ √
H
595902031 595902030 80 3” 128 279 √ √
595902041 595902040 100 4” 222,5 330 √ √
595902061 595902060 150 6” 297 406 √ √
595902081 595902080 200 8” 365 495 √ √
595902101 595902100 250 10” 417,5 559 √ √
595902121 595902120 300 12” 453 660 √ √

2 in. to 3 in. (DN50 to DN80)


Parts List
Description Material L
Body Ductile Iron*
Cover Ductile Iron*
Clapper Carbon Steel**
Clapper Arm Ductile Iron*
Hinge Pin Stainless Steel AISI 304
Seat Bronze
* Ductile iron conforming to ASTM A-536, Grade 65-5-12
** Carbon steel conforming to A36 SS304 EPDM H

4 in. to 12 in. (DN100 to DN300)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–37
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Check Valves


Model 8800

Wafer Double Door ANSI PN10/PN16 Flanges Check Valve


Sizes DN50 - DN300 (2" - 12")

Approvals UL Listed & FM Approved

Maximum Working
12,1 bar (175 psi)
Pressure

End Connection Wafer - ANSI PN10/PN16

Tech Data Sheet Contact Tyco for details

Wafer style double door check valve

ANSI Class 125


Bolt Circle
ISO Bolt Circle A
C
B Dia.

Minimum
E Companion D
Flange Bore

Model 8800 Wafer Double Door ANSI Check Valve


Dimensions mm Weight Approval & Listings
Part No. DN
A B C D E kg FM UL
880000600 50 2” 54 130 0 73 0 1,8 √ √
880000890 80 3” 67 143 5 99 43 3,2 √ √
880001140 100 4” 67 197 16 121 78 4,1 √ √
880001680 150 6” 95 219 21 159 108 8,6 √ √
880002190 200 8” 127 311 25 203 140 17,2 √ √
880002730 250 10” 140 375 52 260 216 29,5 √ √
880003240 300 12” 181 441 49 305 235 42,6 √ √

Parts List
Item No. Description
1 Body
2 Disc
3 Torsion Spring
9 2
4 Disc Hinge Pin
5 Disc Stop Pin 3 7
6 Disc Thrust Bearing
7 Hinge Pin Retainer
8 Stop Pin Retainer
9 Stabilization Sphere
10 Spacer
6
8 4 5
10

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–38
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Check Valves
Model C

Twin Plate Wafer Check Valve


Sizes DN50 - DN300 (2" - 12")

Approvals CE, VNIIPO

Maximum Working
16 bar (230 psi)
Pressure

End Connection Wafer - ANSI PN10/PN16

Tech Data Sheet Contact Tyco for details

Wafer style twin plate check valve

Model C Wafer Twin Plate Check Valve


Dimensions mm Approval & Listings
Fire
Part No. DN
A B C E F G CE Academy of VNIIPO
Russia
C7310604 50 2” 108 43 58 12 33 22 √ √ √
C7310764 65 2-1 ⁄ 2” 128 46 58 12 33 25 √ √ √
C7310894 80 3” 143 64 71 18 41 33 √ √ √
C73101144 100 4” 163 64 96 28 52 26 √ √ √
C10701683 150 6” 219 76 128 33 70 35 √ √ √
C10702193 200 8” 275 89 192 60 104 36 √ √ √
C10702733 250 10” 329 114 244 81 126 48 √ √ √
C10703243 300 12” 380 114 295 100 153 49 √ √

Parts List
Item No. Description
Body Cast iron
Seat EPDM

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–39
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Check Valves


Model 85
Wafer Check Valve
Sizes DN40 - DN80 (1-1/2" - 3")

Maximum Working
16 bar (230 psi)
Pressure

Body Stainless Steel Type 316

Seat NBR

End Connection Wafer - ANSI PN10/PN16

Tech Data Sheet Contact Tyco for details

Wafer style check valve

C B A

Model 85 Wafer Check Valve


Dimensions mm Weight
Part No. DN
A B C D E kg
85200DN40 40 1-1 ⁄ 2” 22 95 79 14 23 0,7
85200DN50 50 2” 32 109 87 14 49 0,9
85200DN65 65 2-1 ⁄ 2” 40 129 109 14 75 1,2
85200DN80 80 3” 54 144 119 14 126 1,5

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–40
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Check Valves
Model Reto Stop
Flange Check Valve
Sizes DN50 - DN300 (2" - 12")

Approvals WRC

Maximum Working
16 bar (230 psi)
Pressure

Body Ductile Iron

Coating Epoxy Blue

End Connection Flange - ANSI PN10/PN16

Tech Data Sheet Contact Tyco for details

Flanged check valve

F-F D

Model RETO STOP Check Valve


Approval &
Pn Dimensions mm Temp Weight
Part No. DN Listings
Bar °C kg
F-F H D WRC
NO403 80 3” 16 241 225 65 15 √
NO369 100 4” 16 292 250 65 22 √
NO374 150 6” 16 356 330 65 35 √
NO379 200 8” 16 495 385 65 60 √
NO384 250 10” 16 622 395 65 105 √
NO389 300 12” 16 698 538 65 139 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–41
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Check Valves


Model 62S

Threaded Check Valve


Sizes DN15 - DN50 (1 ⁄ 2” - 2")

Maximum Working
27 bar (392 psi)
Pressure

Body Bronze

Seat Buna-N

End Connection NPT Threads

Tech Data Sheet Contact Tyco for details

For horizontal installation only • Valve is NOT spring loaded

Model RETO STOP Check Valve


Pn Dimensions mm Weight
Part No. DN
Bar A B kg
1
62S00210D 15 ⁄ 2” NPT 27 67,5 38,9 0,4
3
62S00270D 20 ⁄4” NPT 27 78,6 47,6 0,6
62S00340D 25 1” NPT 27 89,7 53,2 0,8
62S00420D 32 1-1 ⁄4” NPT 27 130,2 92,1 2,6
62S00480D 40 1-1 ⁄ 2” NPT 27 130,2 92,1 2,6
62S00600D 50 2” NPT 27 141,3 115,9 4,5
For horizontal installation only

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–42
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Check Valves
Model N5
Flange Check Valve
Sizes DN15 - DN50 (1 ⁄ 2” - 2")

Maximum Working
12 - 16 bar (174 - 232 psi)
Pressure

Body Brass

Coating Epoxy Blue

End Connection BSP Threads

Tech Data Sheet Contact Tyco for details

Suitable for Water, oil and air. Max. 100°C • For vertical installation only • Valve is NOT spring loaded

Model RETO STOP Check Valve


Pn Dimensions mm Weight
Part No. DN
Bar Length kg
1
N500210 15 ⁄ 2” BSP 16 47 0,2
3
N500270 20 ⁄4” BSP 16 54,5 0,3
N500340 25 1” BSP 16 64,5 0,5
N500420 32 1-1 ⁄4” BSP 12 75,5 0,6
N500480 40 1-1 ⁄ 2” BSP 12 83 0,7
N500600 50 2” BSP 12 98 1,0
For vertical installation only

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–43
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Strainers


Model TJST
“Y” Flanged Strainer
Sizes DN50 - DN300 (2” - 12")

Approvals UL/ULC Listed

Maximum Working
20,7 bar (300 psi)
Pressure

End Connection Flanged ANSI Clas 125 / PN16

Tech Data Sheet TFP1564

The TYCO Model TJST Y-Strainer provides strainer protection for piping equipment such as pumps, meters, valves, compressors,
traps and similar equipment. • Flanged ends • Standard screen made of perforated stainless steel

Model TJST Flanged "Y" Strainer


Dimensions mm
Part No. Approval & Listings
Mesh Data
Pressure
M2 Weight
DN M1 Loss
L H H1 Number of kg
ANSI 125 PN16 Hole bar UL FM
Holes per
Dia.
Square Inch
596001021 596001020 50 2” 203 132 195 3,18 30 0,50 √ √
596001026 596001025 65 2-1 ⁄ 2” 254 158 240 3,18 30 0,41 √ √
596001031 596001030 80 3” 260 175 270 3,4 35 0,57 √ √
596001041 596001040 100 4” 308 202 320 4,78 17 0,41 √ √
596001061 596001060 150 6” 472 334 495 6,0 10 0,33 √ √
596001081 596001080 200 8” 550 391 570 6,0 10 0,40 √ √
596001101 596001100 250 10” 654 460 700 6,0 10 0,50 √ √
596001121 596001120 300 12” 762 590 840 6,0 10 0,40 √ √

Material List L
Description Material
Body Ductile Iron*
Cover Ductile Iron*
Screen Stainless Steel AISI 304
Gasket EPDM Rubber**
Plug Carbon Steel
* Ductile iron conforming to ASTM A-536, Grade 65-5-12
** Ethylene propylene diene monomer rubber

H1

M1

M2

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–44
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Strainers
760P
“Y” Strainer
Approvals UL Listed

Maximum Working DN50 thru DN150 - 20,7 bar (300 psi)


Pressure DN200 thru DN300 - 12 bar (175 psi)

Temperature Rating 0° to 100°C (32° to 200°F)

Screen Stainless Steel Type 304

Body and Cover ASTM A-536, Grade 65-45-12

End Connection Grooved

Tech Data Sheet G422

The Figure 760P “Y” Strainer provides economical strainer protection for piping equipment such as pumps, meters, valves,
compressors, traps and similar equipment, from debris and foreign matter.

Figure 760P - “Y” Strainer


Approval & L
Nominal Size Nominal Dimensions
Listings A
Part No.
ANSI OD Ød A B L UL B
760P000601 50 60.3 57.2 15.9 7.9 247.5 √
760P000731 65 73.0 69.1 15.9 7.9 273.0 √
760P000761 65 76.1 69.1 15.9 7.9 298.5 √
760P000891 80 88.9 84.9 15.9 7.9 362.0 √
760P001141 100 114.3 110.1 15.9 9.6 419.0 √
OD Ød
760P001391 125 139.7 137.0 15.9 9.6 419.0 √
760P001411 125 141.3 137.0 15.9 9.6 419.0 √
1
760P001651 150 165.1 164.0 15.9 9.6 470.0 √
760P001681 150 168.3 164.0 15.9 9.6 470.0 √ 2 4
760P002191 200 219.1 214.4 19.1 11.1 609.5 √
3 5
760P002731 250 273.1 268.3 19.1 12.7 686.0 √
760P003241 300 323.9 318.3 19.1 12.7 762.0 √

Material List
A C
No. Description Material 2"− 2-1/2" 5"
(DN50 − DN65) (DN125)
1 Valve Body ASTM A536, 65-45-12 STRAINERS: STRAINER:
0.16" (4,0 mm) 0.24" (6,0 mm)
2 Screen AISI 304 DIA. HOLES DIA. HOLES
3 Rigid Coupling ASTM A536, 65-45-12 24 HOLES SQ. IN. 13 HOLES SQ. IN.
48% OPEN AREA 58% OPEN AREA
4 Cap ASTM A536, 65-45-12
Malleable Iron Galvanized or
5 Plug
Bronze ASTM B564 B D
3" − 4" 6" − 12"
(DN80 − DN100) (DN150 − DN300)
STRAINERS: STRAINERS:
0.20" (5,0 mm) 0.25" (6,3 mm)
DIA. HOLES DIA. HOLES
17 HOLES SQ. IN. 11 HOLES SQ. IN.
53% OPEN AREA 56% OPEN AREA

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–45
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Strainers


F
ANSI Flanged Cross Strainer

Approvals UL Listed

Maximum Working
10 - 16 bar (145 - 232 psi)
Pressure

Body Cast Iron GGG50

End Connection ANSI 125 Flange

Tech Data Sheet Contact Tyco for details

Table Spare Part


Approval & Part No. Plug
Part No. Dimensions mm
Pn Weight Listings 195524 2pcs.
Dn
Without With [Bar] kg
A H1 H2 VDS
Gauges Gauges Plugs needed when Guages are
840653 126303 80 16 310 165 115 19 √ not ordered
840654 126303 100 16 350 160 150 30 √
840655 126303 150 16 450 260 170 57 √
841088 126303 200 10 550 355 195 95 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–46
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Strainers
807
AQUAMIST Strainer
Sizes DN25 - DN50 (1" - 2")

Maximum Working
32 bar (464 psi)
Pressure

Screen Holes 0.75mm

Screen Stainless Steel Type 304

Body Gunmetal

End Connection BSP Thread

Tech Data Sheet Contact Tyco for details

A
Model 807
PN Dimensions mm
Part No. DN Cv Kv Weight
[Bar] A B
8070347 25 1” BSP 32 95 89 17.5 15.1 0.9
8070427 32 1-1/4” BSP 32 115 97 30.6 26.4 1.5
8070487 40 1-1/2” BSP 32 130 116 37 31.9 1.8 B
8070607 50 2” BSP 32 153 159 60.9 52.5 3.3

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–47
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Strainers


74A
Strainer
Sizes DN15 - DN50 (1/2" - 2")

Maximum Working
20 bar (290 psi)
Pressure

Screen Holes 0.65mm

Screen Stainless Steel Type 304

Body Bronze

End Connection BSP Thread

Tech Data Sheet Contact Tyco for details

Model 74A
A
PN Dimensions mm
Part No. DN Weight
[Bar] A B
305003 15 1/2” BSP 20 59 40 0.23
305004 20 3/4” BSP 20 66 46 0.5
305005 25 1” BSP 20 76 58 1
305006 32 1-1/4” BSP 20 92 70 1.2
B
305007 40 1-1/2” BSP 20 100 80 2
305009 50 2” BSP 20 125 100 2.5

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–48
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Strainers
557
Strainer
Sizes DN15 (1/2")

Maximum Working
12,1 bar (175 psi)
Pressure

Screen Holes 50 mesh

Screen Stainless Steel Type 304

Body Bronze

End Connection BSP Thread

Tech Data Sheet Contact Tyco for details

MODEL 557 A
PN Dimensions mm
Part No. DN Weight
[Bar] A B
20005025 15 1/2” NPT 12 74.7 50.8 0.4

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–49
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Hydrants


Super Centurion Straight
Super Centurion Hydrant with Straight Connection
Sizes 4" - 6"

Maximum Working 2-Way: 13,8 bar (200 psi)


Pressure 3-Way: 17,2 bar (250 psi)

End Connection Flange ANSI PN10/PN16

Wrench A-311 1-1 ⁄ 2” Pentagon

Tech Data Sheet Contact Tyco for details

Order by specification. • Examples of Part No. with standard US outlets

Model Super Centurion + Straight Conn.


Approval &
Main
2 or 3 Hose Pumper Bury Weight Listings
Part No. Model Shoe Valve
Way Nozzle Nozzle mm kg
mm FM

420-513664 A420 4” PN10 2 2 x 2-1 ⁄ 2” - 114 1067 170


420-511536 A420 4” ANSI 2 2 x 2-1 ⁄ 2” - 114 1219 170
421-511535 A421 6” ANSI 3 2 x 2-1 ⁄ 2” 4-1/2 114 1219 180 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–50
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Hydrants
Super Centurion Straight

Parts List
Nr. Discription Material
1 Operating nut Bronze
2 Wiper ring Rubber
3 Hold down nut “O” ring Rubber
4 Hold down nut Bronze
5 Bonnet “O” ring Rubber
6 Anti-friction washer Plastic
7 Oil filler plug Brass
8 Bonnet Cast Iron
9 Bonnet Bolts Steel
10 Bonnet Gasket Rubber
11 Upper stem Steel
12 Stem “O” rings Rubber
13 Nozzle lock Stainless steel
14 Pumper nozzle Bronze
15 Pumper nozzle gasket Rubber
16 Pumper nozzle “O” ring Rubber
17 Pumper nozzle cap Cast iron
18 Hose nozzle Bronze
19 Hose nozzle gasket Rubber
20 Hose nozzle “O” ring Rubber
21 Hose nozzle cap Cast iron
22 Chains Steel
23 Chain connector hook Steel
24 Upper barrel Cast iron
25 Safety stem coupling Steel
26 Safety flange bolt Steel
27 Safety flange gasket Rubber
28 Safety flange Cast iron
29 Cotter pins Stainless steel
30 Clevis pins Stainless steel
31 Lower stem Steel
32 Lower barrel Cast iron
33 Stem pin Stainless steel
34 Drain valve facing Plastic
35 Drain valve facing screw Stainless steel
36 Upper valve plate Bronze
37 Shoe bolt Steel
38 Drain ring housing gasket Rubber
39 Top seat ring “O” ring Rubber
40 Drain ring housing Cast iron
41 Drain ring housing bolt Steel
42 Drain ring Bronze
43 Seat ring Bronze
44 Bottom seat ring “O” ring Rubber
45 Main valve Rubber
46 Lower valve plate Cast iron
47 Cap nut seal Rubber
48 Lock washer Stainless steel
49 Cap nut Cast iron
50 Shoe Cast iron

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–51
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Hydrants


Super Centurion Duck Foot
Super Centurion Hydrant with Duck Foot
Approvals UL Listed & FM Approved

Maximum Working 2-Way: 13,8 bar (200 psi)


Pressure 3-Way: 17,2 bar (250 psi)

End Connection Flange ANSI PN10/PN16

Wrench A-311 1-1 ⁄ 2” Pentagon

Tech Data Sheet Contact Tyco for details

Order by specification. • Examples of Part No. with standard US outlets

Bury depth of 1'6" minimum.


Longer versions can be
ordered in 6" intervals

ANSI 125 Flanged

Model Super Centurion + Duck Foot


Approval &
Dimensions mm
2 or 3 Hose Valve/ Pumper Main Weight Listings
Part No Model Bury
Way Nozzle Nozzle Valve kg
A B UL FM

433-508179 A433 2 nozzle - 114 1219 451 794 180 √ √


421-500358 A421 3 nozzle 4-1 ⁄ 2 114 1219 451 794 185 √ √
435-504195 A435 2 nozzle - 133 1219 438 784 180 √ √
423-500158 A423 3 nozzle 4-1 ⁄ 2 133 1219 438 784 185 √ √
433-519499 A433 2 valve A-373 - 114 1219 451 794 180 √ √
421-520731 A421 3 valve A-373 4-1 ⁄ 2 114 1219 451 794 185 √ √
435-519515 A435 2 valve A-373 - 133 1219 438 784 180 √ √
421-500357 A421 3 nozzle 4-1 ⁄ 2 114 1067 451 794 180 √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–52
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Hydrants
Super Centurion Duck Foot

Parts List
Nr. Discription Material
1 Operating nut Bronze
2 Weather seal Rubber
3 Hold down nut “O” ring Rubber
4 Hold down nut Bronze
5 Bonnet “O” ring Rubber
7 Oil filler plug Brass
8 Bonnet Cast Iron
9 Bonnet Bolts & nut Steel
10 Bonnet Gasket Rubber
11 Upper stem Steel
12 Stem “O” rings Rubber
13 Nozzle lock Stainless steel
14 Pumper nozzle Bronze
15 Pumper nozzle gasket Bronze
16 Pumper nozzle O-Ring Rubber
17 Pumper nozzle cap Rubber
18 Hose nozzle Bronze
19 Hose nozzle gasket Rubber
20 Hose nozzle “O” ring Rubber
21 Hose nozzle cap Cast Iron
23 Chains connector ring Steel
22 Chain Steel
24 Upper barrel Cast Iron
26 Safety flange bolt & nut Steel
25 Safety stem coupling Steel
27 Safety flange gasket Rubber
28 Safety flange Cast Iron
30 Clevis pins Stainless steel
29 Cotter pins Stainless steel
31 Lower stem Steel
32 Lower barrel Cast Iron
33 Stem pin Stainless steel
34 Drain valve facing Plastic
35 Drain valve facing screw Stainless steel
36 Upper valve plate Bronze
37 Shoe bolt & nut Steel
38 Drain ring gasket Rubber
39 Top seat ring “O” ring Rubber
42 Drain ring Bronze
41 Drain ring bolt & nut Steel
43 Seat ring Bronze
44 Bottom seat ring “O” ring Rubber
45 Main valve Rubber
46 Lower valve plate Cast Iron
48 Cap nut seal Rubber
47 Lock washer Stainless steel
49 Cap nut Cast Iron
50 Shoe Cast Iron
51 Hydratant lubricating oil
52 Plug

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–53
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Hydrants


Model A-373
Hose Gate Valve for use with Super Centurion Hydrant

Approvals UL Listed & FM Approved

Maximum Working
12,1 bar (175 psi)
Pressure

Tech Data Sheet Contact Tyco for details

Model A-373 for Super Centurion Hydrants


Dimensions mm Weight Approval & Listings
Part No Dn
A B C D E F G kg UL FM
A37300765 65 2-1 ⁄ 2” NST 64 229 127 208 22 187 143 7,5 √ √

parts list
Nr. Discription Material
HG-1 Stuffing box Bronze
HG-2 “O” ring packing Rubber
HG-3 Bonnet bushing Bronze
HG-4 Stem Manganese bronze
HG-5 Bonnet Cast Iron
HG-6 Hose nozzle Bronze
HG-7 Body Cast Iron
HG-8 Hose nozzle gasket Rubber
HG-9 Hose nozzle cap Cast Iron
HG-10 Bonnet gasket Rubber
HG-11 Cotter pin Brass
HG-12 Wedge nut Bronze
HG-13 Disc Bronze
HG-14 Chain Steel
HG-15 Cap nut Steel
HG-16 Handwheel Ductile iron
HG-17 Bonnet bolt Steel
HG-18 “O” ring Rubber
HG-19 Valve seat Rubber
HG-20 Retaining rivet Copper

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–54
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Hydrants
Model 70B
Hose Gate Valve

Approvals UL Listed & FM Approved

Maximum Working
12,1 bar (175 psi)
Pressure

Tech Data Sheet Contact Tyco for details

Model CIM 70B including STORZ Coupling & Cap


PN Length Weight
Part No DN Coupling
[Bar] mm kg
70C00601 50 2” BSP 16 STORZ C [66mm] 72 2,4
70C00763 65 2-1 ⁄ 2” BSP 16 STORZ B [89 mm] 80 3,4

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–55
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Hydrants


Saphir
Hydrants

Tech Data Sheet Contact Tyco for details

Model Saphir
Nom. Flow Turns to Dimensions mm Weight
Part No DN Flanges Outlets
in m3/h Open A C D E F kg
SAPH001 80 30 ISO 1 x 65 + 2 x 40 13 665 1000 430 480 135 66
SAPH002 100 60 ISO 1 x 100 + 2 x 65 13 770 1000 440 545 160 96
SAPH003 100 CHOC 60 ISO 1 x 100 + 2 x 65 13 750 1000 420 525 160 113
SAPH004 150CHOC 120 ISO 2 x 100 + 1 x 65 17 780 1000 420 550 195 182

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–56
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Hydrants
EMERAUDE CS
Hydrants

Tech Data Sheet Contact Tyco for details

Model Emeraude CS

Nom. Flow Turns to Dimensions mm Weight


Part No DN Flanges Outlets
in m3/h Open A C D E F kg

CS00890 80 30 ISO 1 x 65 + 2 x 40 13 350 800 1040 435 560 135


CS01140 100 60 ISO 1 x 100 + 2 x 65 13 350 800 1000 450 525 160
CS11140 100 CHOC 60 ISO 1 x 100 + 2 x 65 13 350 800 1000 450 525 160
CS01680 150 CHOC 120 ISO 2 x 100 + 1 x 65 17 350 800 1000 450 525 195

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–57
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Test Equipment


Model 1000
Test and Drain Valve

Approvals UL Listed & FM Approved

Maximum Working
20,7 bar (300 psi)
Pressure

End Connection Threaded NPT or BSP

Tech Data Sheet Contact Tyco for details

Model 1000
Part No Dimensions mm Weight Approval & Listings
DN
BSP NPT A B C D E F G H kg UL FM
3
1000N027- 1000N027- 20 ⁄4 ” 129 45 60 105 86 45 116 160 2 √
1000B034- 1000N034- 25 1” 129 45 60 105 86 45 116 160 2 √ √
1000B042- 1000N042- 32 1-1 ⁄4” 138 45 73 117 84 49 140 189 2,5 √ √
1000B048- 1000N048- 40 1-1 ⁄ 2” 151 45 94 138 89 60 205 265 4 √ √
1000B060- 1000N060- 50 2” 151 45 94 138 89 60 205 265 4 √ √

Part Number Suffix Selection


Orifice
Suffix K
Size
3
0 ⁄ 8” 40
7
1 ⁄ 16” 57
1
2 ⁄ 2” 80
17
3 ⁄ 32” 115
5
*4 ⁄ 8” 160*
3
*5 ⁄4 ” 200*/242*
*7 - 363

Parts List
Description Material
Body Bronze
Handle Steel
Seat Impregnated Teflon
Handle Lock Spring Steel
Sight Glass Fused Tempered Glass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–58
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Test Equipment
Model A59
Branch Line Tester

Approvals UL Listed & FM Approved

Maximum Working
20,7 bar (300 psi)
Pressure

Body Brass

End Connection Threaded

Tech Data Sheet Contact Tyco for details

1/2" NPT

1"
B
NPT

1" E
NPT

Model A59 Branch Line Tester

PN Dimensions mm Weight Approval & Listings


Part No. Dn
[Bar] A B C D E kg UL FM
A5900340 25 1” NPT 12 34 56 102 38 33 0,4 √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–59
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Test Equipment


Model A61
Test and Drain Valve

Approvals UL Listed & FM Approved

Maximum Working
20,7 bar (300 psi)
Pressure

Body Forged Brass

End Connection Female x Female Threaded or Groove x Groove

Tech Data Sheet Contact Tyco for details

It combines the function of testing and draining the system.

Model A61 Test and Drain Valve Model A61 Test and Drain Valve
Approval & Approval &
End End
Part No. Size Orifice Listings Part No. Size Orifice Listings
Connection Connection
UL FM UL FM
7
A61Y001 3
⁄ 8” - K=2.8 √ √ A61Y080 ⁄ 16” - K=4.2 √ √
1
A61Y003 7
⁄ 16” - K=4.2 √ √ A61Y082 ⁄ 2” - K=5.6 √ √
1” 17
A61Y005 Threaded 1
⁄ 2” - K=5.6 √ √ A61Y083 ⁄ 32” - K=8.0 √ √
NPT 2” 3
A61Y009 3
⁄4” - K=14.0 √ √ A61Y085 Grooved ⁄4” - K=14.0 √ √
Grooved 15
A61Y015 17
⁄ 32” - K=8.0 √ √ A61Y086 ⁄ 16" - K=16.8 √ √
15
A61Y002 3
⁄ 8” - K=2.8 √ √ A61Y087 ⁄64" - K=22.4 √ √
19
A61Y004 7
⁄ 16” - K=4.2 √ √ A61Y088 ⁄64" - K=25.2 √ √
3
A61Y006 1-1 ⁄4” 1
⁄ 2” - K=5.6 √ √ A61Y101 ⁄ 8” - K=2.8 √ √
Threaded A61Y103 7
⁄ 16” - K=4.2 √ √
A61Y010 NPT 3
⁄4” - K=14.0 √ √ 1” 1
A61Y012 5
⁄ 8” - K=11.0 √ √ A61Y105 Threaded ⁄ 2” - K=5.6 √ √
BSP 3
A61Y016 17
⁄ 32” - K=8.0 √ √ A61Y109 ⁄4” - K=14.0 √ √
17
A61Y030 7
⁄ 16” - K=4.2 √ √ A61Y115 ⁄ 32” - K=8.0 √ √
3
A61Y032 1
⁄ 2” - K=5.6 √ √ A61Y102 ⁄ 8”” - K=2.8 √ √
7
A61Y033 17
⁄ 32” - K=8.0 √ √ A61Y104 ⁄ 16” - K=4.2 √ √
1
A61Y034 2” 5
⁄ 8” - K=11.2 √ √ A61Y106 1-1 ⁄4” ⁄ 2” - K=5.6 √ √
Threaded Threaded
A61Y035 NPT 3
⁄4” - K=14.0 √ √ A61Y110 BSP 3
⁄4” - K=14.0 √ √
5
A61Y036 15
⁄ 16" - K=16.8 √ √ A61Y112 ⁄ 8” - K=11.0 √ √
17
A61Y037 15
⁄64" - K=22.4 √ √ A61Y116 ⁄ 32” - K=8.0 √ √
7
A61Y038 19
⁄64" - K=25.2 √ √ A61Y130 ⁄ 16” - K=4.2 √ √
1
A61Y052 3
⁄ 8” - K=2.8 √ √ A61Y132 ⁄ 2” - K=5.6 √ √
17
A61Y056 1
⁄ 2” - K=5.6 √ √ A61Y133 ⁄ 32” - K=8.0 √ √
1-1 ⁄4” A61Y134 2” 5
⁄ 8” - K=11.2 √ √
A61Y058 Grooved 17
⁄ 32” - K=8.0 √ √ Threaded
Grooved 3 A61Y135 BSP 3
⁄4” - K=14.0 √ √
A61Y060 ⁄4” - K=14.0 √ √
15
A61Y062 5
⁄ 8” - K=11.0 √ √ A61Y136 ⁄ 16" - K=16.8 √ √
15
A61Y137 ⁄64" - K=22.4 √ √
19
A61Y138 ⁄64" - K=25.2 √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–60
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Test Equipment
Test Kit - Sprinklers
Test Kit for Sprinklers

Maximum Working
20,7 bar (300 psi)
Pressure

End Connection Threaded - GK coupling

Tech Data Sheet Contact Tyco for details

Test Kit Sprinklers


Part No.
G K-Factor
2/3
Without
With Blinddcap
Blindcap
TK-K57 TK-K57-EC 1” BSP 57
TK-K80 TK-K80-EC 1” BSP 80
TK-K115 TK-K115-EC 1” BSP 115
4
TK-K160 TK-K160-EC 1” BSP 160
TK-K200 TK-K200-EC 1” BSP 200
TK-K245 TK-K245-EC 1” BSP 245
TK-K363 TK-K363-EC 1-1 ⁄ 2” BSP 363

Parts List 1

Nr. Descriptoin

Ball Valve Brass, Full Bore Model 1610


1
BSP Threaded Ends Size 1” PN30 kv=43
2 Coupling GEKA 1” Male Brass G
3 Blind Cap for Coupling GEKA 1” Male Brass
Orifice Ring for Test Kit K-57, Brass OD = 30 mm ID = 9,5 mm
Orifice Ring for Test Kit K-80, Brass OD = 30 mm ID = 11,2 mm
Orifice Ring for Test Kit K-115, Brass OD = 30 mm ID = 13,4 mm
4 Orifice Ring for Test Kit K-160, Brass OD = 30 mm ID = 15,9 mm
Orifice Ring for Test Kit K-200, Brass OD = 30 mm ID = 17,8 mm
Orifice Ring for Test Kit K-245, Brass OD = 30 mm ID = 19,8 mm
Orifice Ring for Test Kit K-363, Brass OD = 43 mm ID = 25 mm

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–61
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Test Equipment


Test Kit - Flow Switches
Test Kit for Flow Switches

Approvals VdS

Maximum Working
20,7 bar (300 psi)
Pressure

1
End Connection ⁄ 2” and 3 ⁄4" NPT

Tech Data Sheet Contact Tyco for details

Test Kit 3/4" NPT


Part No. K VDS
PESM027AGR 30 √ 1
PESM027CGR 57 √
PESM027DGR 80 √
PESM027EGR 115 √

Parts List 2
Item Description
Close Nipple, Fig. 280
1
Galvanized 3/4"
Ball Valve Brass, Full Bore
2 Model 1610 BSP Threaded Ends
3
Size 3/4” PN30 kv=29,5
Pressure Gauge
Type 111.10.100 0-16 Bar
3
1/2” ISO RC Thread conform DIM,
Class 1.6 100 mm
Nipple 1/2” M/F Orifice
7.1 mm Brass [PESM027AGR]
Nipple 1/2” M/F Orifice
9.5 mm Brass [PESM027CGR]
4
Nipple 1/2” M/F Orifice 4
11.2 mm Brass [PESM027DGR]
Nipple 1/2” M/F Orifice
13.4 mm Brass [PESM027EGR] 1/2" NPT

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–62
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Test Equipment
Model BH-19
Sight Flow Connections

Maximum Working
12,1 bar (175 psi)
Pressure

End Connection 1" and 2" NPT or ISO

Tech Data Sheet Contact Tyco for details

A
B

Model BH-19 - Sight Flow Connection


PN Dimensions mm Weight
Part No. DN
[Bar] A B kg
BH0025 25 1” ISO 12,1 82 51 0,3
BH0025N 25 1” NPT 12,1 82 51 0,3
BH0050 50 2” ISO 12,1 85 51 0,5
BH0050N 50 2” NPT 12,1 85 51 0,5

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–63
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Pressure Relief Valves


RV-1A
Pressure Relief Valve Pilot-Operated
Sizes DN50 thru DN200 (2" thru 8")

Approvals UL Listed & FM Approved

Maximum System
20,6 bar (300 psi)
Pressure

Field Relief “Set


2,1 to 17,2 bar (30 to 250 psi)
Pressure” Range

Temperature Range 10°C to 80°C (50°F to 175°F)

End Connection Groove x Groove or Flange x Flange

Flange Drilling ANSI & ISO

Tech Data Sheet TFP1586

Automatically relieves excess pressure in a fire protection system to maintain a relatively constant system pressure as flow
demands change • Uses the DV-5A valve body, incorporating the simple diaphragm design • One pilot valve provides for any outlet
"set pressure" thanks to sub-assembly • No need to bleed trapped air from the diaphragm chamber • Simple trim configuration •
Factory assembled and fully trimmed • In-line service

RV-1A - Grooved Ends

Model RV-1A - Groove x Groove


Size O.D. Pipe Dimension mm Approval & Listings
Weight
Part No. Size
DN In A B C D E kg UL FM
mm
550013020 50 2" 60,3 260 71,1 283,7 150,6 165,9 15,4 √ √
550013030 80 3" 88,9 349 74,9 326,1 204,5 204,5 32,2 √ √
550013040 100 4" 114,3 425 76,2 358,4 226,8 242,1 48,1 √ √
550013060 150 6" 168,3 569 114,8 393,7 315,7 280,2 82,6 √ √
550013080 200 8" 219,1 697 134,4 462,3 366,5 381,8 152,5 √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–64
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Pressure Relief Valves
RV-1A - Flange Ends

E
C

Model RV-1A - Flange x Flange


Part No. Size Dimension mm Weight Approval & Listings
ANSI ISO DN In A B C D E kg UL FM
550023030 550043030 80 3" 349 101,6 326,1 204,5 204,5 37,6 √ √
550023040 550043040 100 4" 425 112,3 358,4 226,8 242,1 57,6 √ √
550023060 550043060 150 6" 569 137,4 393,7 315,7 280,2 94,8 √ √
550023080 550043080 200 8" 697 171,7 462,3 366,5 381,8 169,8 √ √

Specify Flange Drilling;


ANSI B16-1 (Class 125) • ISO 7005-2 (PN16)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–65
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Pressure Relief Valves


Model 7000
Threaded Pressure Relief Valve
Approvals UL Listed & FM Approved

1
Sizes ⁄ 2" NPT

Pressure 12,1 bar (175 psi)

Body Bronze

End Connection NPT Thread

Tech Data Sheet Contact Tyco for details

Model 7000
Approval &
PN Pset Dimensions mm Weight
Part No. DN Listings
[Bar] [Bar] kg
A B C UL FM
1
70000021 15 ⁄ 2” NPT 12,1 12,1 44 25 82,8 0,25 √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–66
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Pressure Relief Valves
Model 55L
Threaded Pressure Relief Valve
Approvals UL Listed & FM Approved

Sizes DN15 - DN20 (1 ⁄ 2” - 3 ⁄4”)

Pressure 27,6 bar (400 psi)

Body Bronze, SS-303

End Connection NPT Thread

Tech Data Sheet Contact Tyco for details

189
45

45

0.71 45
89
114

Model 55L

PN ΔP F Weight Approval & Listings


Part No. DN Material CV
[Bar] [Bar] L/Min@12 Bar kg APSAD UL FM
1
55L00210 15 ⁄ 2” NPT 27,6 1,4-14,0 Bronze 6 300 2,5 - √ √
1
55FKX210 15 ⁄ 2” NPT 27,6 1,4-14,0 SS-303 6 300 2,5 √ - -
3
55F00270 20 ⁄4” NPT 27,6 1,4-14,0 Bronze 8,5 425 2,5 - - -
3
55L00270 20 ⁄4” NPT 27,6 1,4-14,0 Bronze 8,5 425 2,5 - √ √
3
55FKX270 20 ⁄4” NPT 27,6 1,4-14,0 SS-303 8,5 425 2,5 √ - -

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–67
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Pressure Reducing Valves


Model A201 & A203
Threaded Pressure Relief Valve
Approvals UL Listed

Sizes 2-1 ⁄ 2” NPT

Maximum Pressure 27,6 bar (400 psi)

Static Outlet Pressure


4 - 12 bar (60 - 175psi)
Adjustable

Body Bronze

Tech Data Sheet Contact Tyco for details

A201 - Angle A203 - Globe

A A

D
B B

C
C

Model A201 Angle & A203 Globe Type with Internal Check Valve
Approval &
Inlet Conn. Outlet Conn. Dimensions mm Weight
Part No. Model Orientation Listings
Female Female kg
A B C D UL
A20100760 A201 2-1 ⁄ 2” NPT 2-1 ⁄ 2” NPT Angle 200 453 87 95 14 √
A20300760 A203 2-1 ⁄ 2”NPT 2-1 ⁄ 2” NPT Globe. 200 405 203 373 14 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–68
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Pressure Reducing Valves
Model A202 & A204
Threaded Pressure Relief Valve
Approvals UL Listed

Sizes 2-1 ⁄ 2” NPT

Maximum Pressure 27,6 bar (400 psi)

Static Outlet Pressure


4 - 12 bar (60 - 175psi)
Adjustable

Body Bronze

Tech Data Sheet Contact Tyco for details

A202 - Angle A204 - Globe

A
A

D
B
B

C C

Model A202 Angle & A204 Globe Type with Internal Check Valve
Approval &
Inlet Conn. Outlet Conn. Dimensions mm Weight
Part No. Model Orientation Listings
Female Female kg
A B C D UL
A20200760 A202 2-1 ⁄ 2” NPT 2-1 ⁄ 2” NPT Angle 200 453 87 95 14 √
A20400760 A204 2-1 ⁄ 2” NPT 2-1 ⁄ 2” NPT Globe. 200 405 203 373 14 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–69
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Pressure Reducing Valves


MONOSTAB A
Flanged Pressure Relief Valve

Sizes DN40 - DN200 (1-1 ⁄ 2” - 8")

Adjustable A
1.5 - 6 bar (22 - 87 psi)
Downstream Pressure

Adjustable B
5 - 12 bar (75 - 175 psi)
Downstream Pressure

End Connection Flange ISO PN10 /PN16

Tech Data Sheet Contact Tyco for details

Model MONOSTAB A Direct Action

Part No Adjustment Adjustment Dimensions mm


Weight
Dn Flanges Downstream Downstream
kg
Mod A Mod. B Pressure A Bar Pressure B Bar A B C
A00608 B00608 40 / 50 1-1 ⁄ 2” / 2” ISO PN10/16 1,5 - 6 5 - 12 230 86 430 18
A00768 B00768 65 2-1 ⁄ 2” ISO PN10/16 1,5 - 6 5 - 12 290 100 420 22
A00898 B00898 80 3” ISO PN10/16 1,5 - 6 5 - 12 310 112 450 25
A01148 B01148 100 4” ISO PN10/16 1,5 - 6 5 - 12 350 112 450 31
A01398 B01398 125 5” ISO PN10/16 1,5 - 6 5 - 12 400 145 550 60
A01688 B01688 150 6” ISO PN10/16 1,5 - 6 5 - 12 480 145 550 66
A02198 B02198 200 8” ISO PN10 1,5 - 6 5 - 12 600 185 940 120

Parts List
Nr. Description Material Nr. Description Material
Chloroprène
1 Body FGS 13 Membran
reinforced
2 Stem SS inox 14 Clapper pur
Cupro aluminium
3 Seat 15 Guide PEHD
CuAi9Ni3Fe2
O-ring lower
4 Cover FGS 16 EPDM
cylinder
5 lower piston Ductile iron 17 locking nut SS inox A2
6 Clapper support Ductile iron 18 Nut SS inox A2
7 Clapper nut Ductile iron 19 Cover nut SS inox A2
8 Disc Ductile iron 20 Setting screw SS inox X20Cr13
9 Support plate Ductile iron 21 Setting wrench Galvanized steel
10 Body cylinder Ertalon 22* Manometer SS inox
Cupro aluminium Nickel plated
11 Guide stop 23 Gauge valve
CuAi9Ni3Fe2 brass
12 Setting spring Coated steel
*Manometer optional

Chart:
This chart can be used to check when the Monostab
pressure Valve can be used
Zone 1: Normal conditions of service
Zone 2: Cavitation area
Zone 3: Not possible

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–70
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
General Purpose Valves - Pressure Reducing Valves
PRV-1A
Pressure Reducing Valve Pilot Operated
Sizes DN50 thru DN200 (2" thru 8")

Approvals UL, C-UL Listed & FM Approved

Maximum Inlet
17,2 bar (300 psi)
Pressure

Factory Outlet “Set


8,6 bar (125 psi)
Pressure”

6,2 to 12 bar (90 to 175 psi)*


Field Outlet “Set
* = Sizes DN50, DN80, DN150 and DN200 (2", 3", 6" and 8")
Pressure” Range
are rated to a set pressure of 5,5 to 12 bar (80 to 175 psi)

End Connection Groove x Groove, Flange x Flange

Tech Data Sheet TFP1581

Reduces a higher inlet pressure to a lower outlet delivery pressure in water-filled pipes • One pilot valve provides for any outlet
"set pressure" thanks to sub-assembly • Uses the DV-5A valve body, incorporating the simple diaphragm design • Factory
assembled and fully trimmed • In-line service

PRV-1A - Groove Ends

B
A

Model PRV-1A - Groove x Groove


Size O.D. Pipe Dimension mm Approval & Listings
Weight
Part No. Size
DN In A B C D E kg UL FM
mm
550012020 50 2" 60,3 260 71,1 281,7 159,5 227,1 15,9 √ √
550012030 80 3" 88,9 349 74,9 324,4 197,6 227,1 32,2 √ √
550012040 100 4" 114,3 425 76,2 358,6 214,4 214,4 48,1 √ √
550012060 150 6" 168,3 569 114,8 391,4 299,2 277,9 85,3 √ √
550012080 200 8" 219,1 697 134,4 460,0 375,4 366,8 153,3 √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–71
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

General Purpose Valves - Pressure Reducing Valves


PRV-1 - Angle Style

E
C

Model RV-1A - Flange x Flange


Part No. Size Dimension mm Weight Approval & Listings
ANSI ISO DN In A B C D E kg UL FM
550022030 550042030 80 3" 349 101,6 324,4 197,6 227,1 37,6 √ √
550022040 550042040 100 4" 425 112,3 358,6 214,4 214,4 57,6 √ √
550022060 550042060 150 6" 569 137,4 391,4 299,2 277,9 97,5 √ √
550022080 550042080 200 8" 697 171,7 460,0 375,4 366,8 70,6 √ √

Specify Flange Drilling;


ANSI B16-1 (Class 125) • ISO 7005-2 (PN16)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–72
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Other Pump Equipment
Model 15A
Air Release Valves
Approvals UL Listed & FM Approved

Sizes DN15 - DN25 (1 ⁄ 2” - 1")

Maximum Pressure 12 bar (175 psi)

Body Cast Iron

Tech Data Sheet Contact Tyco for details

MODEL 15A
PN Dimensions mm Weight Approval & Listings
Part No. Inlet DN Outlet DN
[Bar] H1 H2 W kg UL FM
1 1
1500210 15 ⁄ 2” NPT 15 ⁄ 2” NPT 12 133 194 121 2,7 √ √
1
1500340 25 1” NPT 15 ⁄ 2” NPT 12 133 194 121 2,7 √ √

H2
H1

Parts list
23
Nr. Description
1 Body
21
2 Cover 14
3 Lever Frame 2
4 Seat
5 Float 6
6 Gasket 17
7 Cover Bolt 4
34 7
10 Float Arm
3
11 Orifice Button
12 Pivot Pin
5
13
13 Pin Retainer (not shown)
14 Pipe Plug 12 1
17 Float Retainer
10
21 Locator
23 Screened Hood
11
34 Lock Washer

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–73
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Other Pump Equipment


Model 24 & Model 302
Foot Valves
Sizes DN100 - DN300 (4" - 12")

Maximum Pressure 10 - 16 bar (145 - 232 psi)

Body Cast Iron

Spring Stainless Steel

Strainer Galvanised Steel

Seal NBR

Tech Data Sheet Contact Tyco for details

Model 24 - DN100-DN250 Model 302 - DN300


A A
B B

D
D

E
E

C C

Model 24 Flanged with Basket


PN Dimensions mm Kv Weight
Part No. DN Drilling
[Bar] A B C D E m3/h kg
24100B1148 100 4” 16 PN10/16 220 185 164 175 142 360 16
24100B1688 150 6” 16 PN10/16 285 248 212 234 200 810 32,7
24100B2198 200 8” 16 PN16 340 345 255 300 300 1080 52
24100B2738 250 10” 16 PN16 405 415 330 370 380 1770 86

Model 302 Flanged with Basket


PN Dimensions mm Kv Weight
Part No. DN Drilling
[Bar] A B C D E m3/h kg
30203247 300 12” 10 PN10 486 482 426 410 242 2210 133,0

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–74
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Other Pump Equipment
FV
Anti-Vortes Plates

Approvals VdS, VAS, CEA

Sizes DN100 - DN300 (4" - 12")

Body Check Valve Galvanised Carbon Steel

Body Basket Galvanised Steel

Tech Data Sheet Contact Tyco for details

ØD ø d1
H ø d2

ØD

Model FV - PN10
Part No. Dimensions mm Approval & Listings
DN
With Basket Without Basket ØD H S Ø d1 Ø d2 t VDS VAS CEA
FV100MAMSG FV100MAOSG 100 4” 114,3 150 400 70 164 18
FV150MAMSG FV150MAOSG 150 6” 168,3 205 600 112 220 20
FV200MAMSG FV200MAOSG 200 8” 219,1 255 800 154 275 22
FV250MAMSG FV250MAOSG 250 10” 273,0 310 1000 200 330 26
FV300MAMSG FV300MAOSG 300 12” 323,9 340 1200 240 380 32
FV350MAMSG FV350MAOSG 350 14" 355,6 380 1200 270 440 38 √ √ √
- FV400MAOSG 400 16" 406,4 - 1600 310 490 44 √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–75
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Other Pump Equipment


Model BAC
Backflow Preventers

Approvals NF, UNI, ANSEAU, BOVERKET

Sizes DN65 - DN200 (2-1 ⁄ 2” - 8")

Body Brass

End Connections Flange - ISO PN10

Tech Data Sheet Contact Tyco for details

Model BAC - Backflow Preventer PN10


Dimensions mm Weight Approval & Listings
Part No. DN
L C D øD F kg NF UNI Anseau BOVERKET
BAC0767 65 2-1 ⁄ 2” 305 132,5 252,5 50 385 17 √ √ √ √
BAC0897 80 3” 470 170 313,5 80 483,5 26,5 √ √ √ √
BAC1147 100 4” 470 170 313,5 80 483,5 28 √ √ √ √
BAC1687 150 6” 600 310 229 90 539 103 √ √ √ √
BAC2197 200 8” 780 350 272 90 622 111 √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–76
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Other Pump Equipment
Model EA
Backflow Preventers

Sizes DN40 - DN250 (1-1 ⁄ 2” - 10")

Body Ductile

End Connections Flange - ISO PN10/PN16

Tech Data Sheet Contact Tyco for details

Model EA
Dimensions mm Weight
Part No. DN Flanges
L H kg
EA00608 40 / 50 1-1 ⁄ 2” / 2” PN10/16 230 135 11
EA768 65 2-1 ⁄ 2” PN10/16 290 150 14
EA898 80 3” PN10/16 310 160 18
EA1148 100 4” PN10/16 350 185 23
EA1398 125 5” PN10/16 400 225 34
EA1688 150 6” PN10/16 480 265 50
EA2197 200 8” PN10 600 330 75
EA2737 250 10” PN10 On request On request 135

EA
Nr. Description
1 Body
2 Cover
3 Clapper
4 Clapper Seat
5 Clapper gasket
6 Axe
7 return spring
8 Drain cap
9 Gauge valve
10 Drain valve

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–77
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Other Pump Equipment


Model 109
Waste Cones

Sizes DN80 x DN125 - DN200 x DN300 (3" x 5" - 8" x 12")

Body Cast Iron

End Connections Flange - ANSI 125

Tech Data Sheet Contact Tyco for details

Model 109
DN Pn Dimensions mm Weight
Part No Flanges
AxB [Bar] C D kg
10930055 80 x 125 3” x 5” 12 ANSI 125 254 102 21
10940065 100 x 150 4” x 6” 12 ANSI 125 254 102 21
10940085 100 x 200 4” x 8” 12 ANSI 125 254 102 21
10960105 150 x 250 6” x 10” 12 ANSI 125 330 127 40
10980125 200 x 300 8” x 12” 12 ANSI 125 330 127 68

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–78
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Other Pump Equipment
Model SV1
Float Valve

Sizes DN25 (1")

Maximum Pressure 10 bar (145 psi)

Body Float Polyethylene

Material Lever Stainless Steel

Tech Data Sheet Contact Tyco for details

SV1
Nr. Description
A Overflow
B Supply Pipe
Maximum filling level at least 20mm
C
below lower edge overflow
D Outlet
Minimum distance between float and
E
tank wall at least 50mm

Model SV642 - Float Valves


PN KV Weight
Part No DN
[Bar] m3/h kg
913796 25 1” BSP 10 18 4,68

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–79
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Other Pump Equipment


Model SV642
Float Valve

Sizes DN50 (2")

Maximum Pressure 10 bar (145 psi)

Body Float Stainless Steel

Material Lever Galvanised Steel

Tech Data Sheet Contact Tyco for details

Model SV642 - Float Valves


PN KV Dimensions mm Weight
Part No DN
[Bar] m3/h A B C øD E F G1 G2 H I kg
777343 50 2” BSP 10 17,4 42 900 116 245 75 53 2” 1-1/2” 245 25 6

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–80
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Other Pump Equipment
Model RAF13
Float Valves

Sizes DN40 - DN300 (1-1 ⁄ 2” - 12")

Maximum Inlet
16 bar (232 psi)
Pressure

Body Ductile Iron

Diaphragm Natural Rubber / Nylon Fabric

Float Arm Assembly Zinc Plated Steel

Tech Data Sheet Contact Tyco for details

H
h
L
B

Model RAF13
Nominal Size Pipe Min. Inlet Kv. factor Control Dimensions mm Approx.
Max. Inlet
Part No. OD Pressure (Open Valve) Chamber Weight
mm In. Pressure (Bar) L H B h
mm (Bar) RAF Volume Kg
RAF-G048 40 1-1 ⁄ 2” 48,3 0,8 16 40 0,06 159 80 96 29 1,8
RAF-G060 50 2" 60,3 0,7 16 70 0,08 190 100 125 38 3,9
RAF-G076 65 2-1 ⁄ 2” 76,1 0,7 16 100 0,16 216 110 125 46 6,7
RAF-G089D 80D 3"D 88,9 0,7 16 130 0,16 244 127 138 50 5,4
RAF-G089 80 3" 88,9 0,6 16 170 0,3 290 138 200 50 10,4
RAF-G114D 100D 4"D 114,3 0,6 16 170 0,3 244 283 222 50 11,1
RAF-G114 100 4" 114,3 0,4 16 290 0,7 346 220 230 60 16,5
RAF-G139 125 5" 139,7 0,4 16 290 0,7 305 167 230 60 16
RAF-G168D 150D 6"D 168,3 0,4 16 300 0,7 325 285 285 143 35,8
RAF-G168 150 6" 168,3 0,4 16 490 1,5 406 240 300 85 30,4
RAF-G219 200 8" 219,1 0,4 16 790 3,5 470 332 354 110 45,6
RAF-G273 250 10" 273,0 0,3 16 1400 7,6 635 374 464 137 75,6
RAF-G324 300 12" 323,9 0,3 16 1800 7,6 749 402 464 162 90

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–81
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Other Pump Equipment


Model RAF13 - Float Valves

L
B

Model RAF13A - Float Valves


Nominal Size Min. Inlet Max. Inlet Kv. factor Control Dimensions mm Approx.
Pipe OD
Part No. Pressure Pressure (Open Valve) Chamber Weight
mm In. mm L H B h
(Bar) (Bar) RAF Volume Kg
RAF-A060 50 2" 60,3 0,7 16 62 0,08 90 150 125 81 4,2
RAF-A076 65 2-1 ⁄ 2” 76,1 0,7 16 90 0,16 117 160 125 83 7,0
RAF-A089D 80D 3"D 88,9 0,7 16 100 0,16 130 170 140 86 6,2
RAF-A089 80 3" 88,9 0,6 16 155 0,3 148 205 200 107 12,0
RAF-A114D 100D 4"D 114,3 0,6 16 155 0,3 155 225 220 110 21,0
RAF-A114 100 4" 114,3 0,4 16 200 0,7 150 227 230 118 15,9
RAF-A168 150 6" 168,3 0,4 16 470 1,5 218 315 300 148 48,7

Trim Only Recommended Flow


Nominal Size DN Flow Rate m3/h
Part No.
mm In.
TRIM-RAF13 40-125 1-1 ⁄ 2” - 5" mm In. Max. Intermittent
TR-RAF13X 150-300 6" - 12" 40 1
1- ⁄ 2” 25 35
50 2" 45 60
65 2-1 ⁄ 2” 70 80
80D 3"D 70 100
80 3" 90 120
100D 4"D 90 120
100 4" 150 180
125 5" 150 200
150D 6"D 150 200
150 6" 320 400
200 8" 550 750
250 10" 950 1150
300 12" 1200 1700

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–82
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Other Pump Equipment
K3-10
Altitude Valves

Sizes DN40 - DN250 (1-1 ⁄ 2” - 10")

End Connections Flange - ISO PN10 / PN16

Tech Data Sheet Contact Tyco for details

Model K3-10 - Altitude Valves


Height Filling Height Setting Dimensions mm Weight
Part No. DN Flanges
Setting m on Request m A B C kg
K30608 40 / 50 1-1 ⁄ 2” / 2” ISO PN10/16 1,5 - 8 6 - 40 230 223 85 29
K30768 65 2-1 ⁄ 2” ISO PN10/16 1,5 - 8 6 - 40 290 242 95 38
K30898 80 3” ISO PN10/16 1,5 - 8 6 - 40 310 262 102 47
K31148 100 4” ISO PN10/16 1,5 - 8 6 - 40 350 287 120 49
K31398 125 5” ISO PN10/16 1,5 - 8 6 - 40 400 383 137 60
K31688 150 6” ISO PN10/16 1,5 - 8 6 - 40 480 430 152 80
K32198 200 8” ISO PN10 / PN16 1,5 - 8 6 - 40 600 554 182 140
K32738 250 10” ISO PN10 / PN16 1,5 - 8 6 - 40 730 595 212 245
*ISO PN10 or PN16 to be specified on the order

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 4–83
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Other Pump Equipment


K3-10 - Altitude Valves

Parts List
Nr. Description Material Nr. Description Material
1 Body FGS 11 Cap Cupro
2 Cover FGS 12 Spring SS inox
3 Seat Bronze CuSn12 13 Pilot Trim SS inox
Bronze CuSn5Zn5pb5 +
4 Axe SS inox x20Cr13 14 Strainer
SS inox 303
DN50-DN200=
5 Clapper Holder FGl/EN-GJl-250 15 Pilot Bronze-SS inox
DN250=FGS

DN50-DN150=Cupro-aluminium
6 Clapper Fixing Ring DN200-DN250=FGl/Aluminium 16 Ball valve Nickel Brass
Bronze
7 Clapper EpDM 17 Speed Controler CuZn39pb3 + X8CrNiS 18.9 + EPDM
8 Membran Elastomer 18 Ball Valve CuZn36pb2As + EPDM
DN50-DN150=FGl
9 Disc 19 Diaphragm SS inox
DN200-DN250=FGS
10 Indicator Cupro + Glass

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

4–84
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Measuring and Electrical Devices
Allow fire protection systems to be interfaced with alarm systems.

- Improved system monitoring - Programmable options for


capabilities specific system requirements

- Able to send an electrical - Installation options for both


or mechanical signal for new and existing systems
alarm/notification purposes

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–1
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

System Testing
SprinklerSense
Self Testing Flow Switches and System Monitoring

Sizes DN50 thru DN150 (2" thru 6")

Approvals LPCB Approved and meets BS EN12259-5 standards.

Max Water Pressure 20 bar (290 psi)

Tech Data Sheet Contact Tyco for details

Intelligent water flow switch designed to enable a sprinkler system’s status to be constantly monitored, tested and recorded to
far greater depths than traditional methods • Uses solid-state sensors with no moving parts and greatly reduces time to test and
commission a system • Offers precise reporting and full audit trail for management purposes • Intelligent Test Module (ITMU) loop
connected with a compatible detector system enhances remote testing and monitoring capabilities • Enhanced diagnostics help
ensure the sprinkler system functionality is continuously monitored for key indicators: flow alarm detection, dry pipe detection,
sensor self-check detection, freeze risk detection, leak detection, battery low alarm, and unit communication failure

SprinklerSense - Self Testing Flow Switches and System Monitoring


Part Size Weight Approval & Listings
Description
Number DN BSP kg LPCB
SPDB9050V 50 2” Vertical Flowswitch 0.8 √
SPDB9065V 65 2-1 ⁄ 2” Vertical Flowswitch 0.8 √
SPDB9080V 80 3” Vertical Flowswitch 0.8 √
SPDB90100V 100 4” Vertical Flowswitch 0.8 √
SPDB90150V 150 6” Vertical Flowswitch 0.8 √
SPDB9050H 50 2” Horizontal Flowswitch 0.8 √
SPDB9065H 65 2-1 ⁄ 2” Horizontal Flowswitch 0.8 √
SPDB9080H 80 3” Horizontal Flowswitch 0.8 √
SPDB90100H 100 4” Horizontal Flowswitch 0.8 √
SPDB90150H 150 6” Horizontal Flowswitch 0.8 √
ITMPCB - - Addressable test unit PCB 0.8 √
FTIM - - Fixed test unit SprinklerSense 0.8 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–2
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Flow Switches
VSR-AT
Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

Sizes DN50 thru DN200 (2" thru 8")

Approvals UL, C-UL Listed & FM, LPCB, & CE Approved

Tech Data Sheet Contact Tyco for details

Electronic vane type waterflow switch for use on wet sprinkler systems • Actuated with a minimum flow of 38 litres per minute
(10GPM) • Retard delay is an adjustable feature that can be set from 0 to 30 seconds • Flow condition must exist for the period of
time necessary to overcome the selected delay period

Model VSR-AT - Electronic Vane Type Waterflow Switch


Size Service Retard Approval & Listings
Part Hole Weight
Pressure Settings
Number DN BSP Size kg UL FM LPCB CE
Bar (psi) (Sec.)
20001720 50 2” 31 (450) 33 ± 2 (1.25" ± 0.125") 0 - 30 1.7 √ √ √ √
20001725 65 2-1 ⁄ 2” 31 (450) 33 ± 2 (1.25" ± 0.125") 0 - 30 1.7 √ √ √ √
20001730 80 3” 31 (450) 50,8 ± 2 (2" ± 0.125") 0 - 30 2.2 √ √ √ √
20001740 100 4” 31 (450) 50,8 ± 2 (2" ± 0.125") 0 - 30 2.4 √ √ √ √
20001760 150 6” 31 (450) 50,8 ± 2 (2" ± 0.125") 0 - 30 2.6 √ √ √ √

Features
Description Specification
Flow Required
38 LPM (10 GPM)
for Alarm

IP Rating IP 54

Temperature 4.5°C - 49°C (40°F - 120°F)

Maximum Surge 5.5 m/s (18 FPS)

Contact Ratings 2.5 AMP @ 125/250 VAC & 30 VDC

141.2 mm
89.0 mm (5.56 in)
50.8 mm
(3.50 in) (2.00 in)

59.4 mm
(2.34 in)

PIPE DIA.
U-BOLT NUT + 133.4 mm
(+ 5.25 in)
U-BOLT WASHER

PIPE SADDLE

PIPE
PLASTIC PADDLE DWG. 1146-14

U-BOLT
NOMINAL PIPE DIA. +73 MM (+2.875in) FOR DN 50 (2in)
NOMINAL PIPE DIA. +54,0 MM (+2.125in) FOR DN 80–200 (3–8in)
NOMINAL PIPE DIA. + 60,3 MM (2.375in) FOR DN 65–(2.5in – 3.5in)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–3
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Flow Switches
VSR-EU
Flow Switch, Vane Type

Sizes DN50 thru DN200 (2" thru 8")

Approvals UL, C-UL Listed & FM, LPCB, VdS, & CE Approved

Tech Data Sheet Contact Tyco for details

Vane type waterflow switch for use on wet sprinkler systems • Actuated with a minimum flow of 38 litres per minute • Retard
delay is an adjustable feature that can be set from 0 to 30 seconds • Flow condition must exist for the period of time necessary to
overcome the selected delay period

Model VSR-EU Flow Switch, Vane Type


Size Retard Approval & Listings
Part P Hole Weight
Settings Fire Academy
Number DN BSP Bar Size kg UL FM LPCB VdS CE VNIIPO T/S/U PAVUS
(Sec.) of Russia
20000608 50 2” 31 33 ± 2 0 - 30 1.7 √ √ √ √ √ √ √ √ √
20000768 65 2-1 ⁄ 2” 31 33 ± 2 0 - 30 1.7 √ √ √ √ √ √ √ √ √
20000898 80 3” 31 50.8 ± 2 0 - 30 2.2 √ √ √ √ √ √ √ √ √
20001148 100 4” 31 50.8 ± 2 0 - 30 2.4 √ √ √ √ √ √ √ √ √
20001418 125 5” 31 50.8 ± 2 0 - 30 2.6 √ √ √ √ √ √ √ √
20001688 150 6” 31 50.8 ± 2 0 - 30 2.6 √ √ √ √ √ √ √ √ √
20002198 200 8” 31 50.8 ± 2 0 - 30 3.2 √ √ √ √ √ √ √ √

Features
Description Specification
15-38 LPM (4-10 GPM) -UL
Flow Sensitivity 30-57 LPM (8-15 GPM) -VdS
No signal below 1 -LPM (2.6 GPM) - VdS

IP Rating IP 54

1° C - 68 ° C - VdS
Temperature
4.5° C - 49 ° C - UL

2 x SPDT [C]
Contacts 10 A - 125/250 VAC
2 A - 30 VDC

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–4
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Flow Switches
VSG
Flow Switch, Low Flow Rate Vane Type

Sizes DN50 thru DN100 (2" thru 4")

Approvals UL and ULC Listed

Tech Data Sheet Contact Tyco for details

Vane type waterflow switch for use in wet pipe water mist systems • Actuated with a minimum flow of 11,4 litres per minute
• Retard delay is an adjustable feature that can be set from 0 to 90 seconds • Flow condition must exist for the period of time
necessary to overcome the selected delay period

Model VSG Flow Switch, Vane Type


Size Approval & Listings
P Hole Weight
Part Number Fire Academy of
DN BSP Bar Size mm kg UL VNIIPO
Russia
30000602 50 2” 31 33 ± 2 2 √ √ √
30000762 65 2-1 ⁄ 2” 31 33 ± 2 2 √ √ √
30000892 80 3” 31 50 ± 2 2.2 √ √ √
300001142 100 4” 31 50 ± 2 2.4 √ √ √

Features
Description Specification
Min. Flow 11,4 L/Min.

IP Rating NEMA 4

Temperature 4,5°C / 49°C

1 x DPDT [C]
Contacts
2 A - 0/30 VDC 0/125 VAC

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–5
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Flow Switches
VS-SP
Flow Switch, Vane Type

Sizes 1" NPT

Approvals UL Listed & CE Approved

Tech Data Sheet Contact Tyco for details

Vane type waterflow switch for use on wet sprinkler systems

Model VS-SP Flow Switch, Vane Type


P Weight Approval & Listings
Part Number Size
Bar kg UL CE
19000480 1" NPT 17 0.92 √ √

Features
Description Specification
Min. Flow 38 L/Min.

IP Rating IP 55

Temperature 4,5°C / 49°C

1 x SPDT [C]
15 A - 125/250 VAC
Contacts 0.5 A - 125 VDC
0.25 A - 250 VDC
2.5 A - 30 VDC

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–6
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Flow Switches
VSR-S
Flow Switch, Vane Type

Sizes 1" NPT

Approvals UL Listed, CE Marked, LPCB Approved

Tech Data Sheet Contact Tyco for details

Vane type waterflow switch for use on wet sprinkler systems • Actuated with a minimum flow of 38 litres per minute • Retard
delay is an adjustable feature that can be set from 0 to 30 seconds • Flow condition must exist for the period of time necessary to
overcome the selected delay period

Model VSR-S Flow Switch, Vane Type


Retard Approval & Listings
P Weight
Part Number Size Settings
Bar kg UL CE LPCB VNIIPO
(Sec.)
20000488 1" NPT 17 0 - 20/30 1.32 √ √ √ √

Features
Description Specification
Flow Sensitivity 15-38 LPM UL

IP Rating IP 54

Temperature 4,5°C / 49°C

2 x SPDT [C]
Contacts 10 A - 125/250 VAC
2 A - 30 VDC

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–7
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Flow Switches
VSR-FE-2
Flow Switch, Vane Type

Sizes DN50 thru DN200 (2" thru 8")

Approvals UL Listed & FM Approved

Tech Data Sheet Contact Tyco for details

Vane type waterflow switch for use on wet sprinkler systems • Actuated with a minimum flow of 38 litres per minute • Retard
delay is an adjustable feature that can be set from 0 to 90 seconds • Flow condition must exist for the period of time necessary to
overcome the selected delay period

Model VSR-FE-2 Flow Switch, Vane Type


Size P Hole Weight Approval & Listings
Part Number
DN BSP Bar Size mm kg UL FM
20000603 50 2” 31 33 ± 2 2 √ √
20000763 65 2-1 ⁄ 2” 31 33 ± 2 2.1 √ √
20000893 80 3” 31 50,8 ± 2 2.6 √ √
20001143 100 4” 31 50,8 ± 2 2.6 √ √
20001683 150 6” 31 50,8 ± 2 3.3 √ √
20002193 200 8” 31 50,8 ± 2 4.3 √ √

Features
Description Specification
Min. Flow 38 L/Min.

NEMA Rating NEMA 4

Temperature +4,5 / +49°C

1 x DPDT [C]
Contacts 2 A - 0/30 VDC
0/125 VAC

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–8
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Flow Switches
VSR-FEX
Explosion Proof Flow Switch, Vane Type

Sizes DN50 thru DN200 (2" thru 8")

Approvals UL Listed & FM & CE Approved

Tech Data Sheet Contact Tyco for details

Vane type waterflow switch for use on wet sprinkler systems • Actuated with a minimum flow of 38 litres per minute • Retard
delay is an adjustable feature that can be set from 0 to 90 seconds • Flow condition must exist for the period of time necessary to
overcome the selected delay period

Model VSR-FEX Explosion Proof Flow Switch, Vane Type


Part Size P Hole Retard Settings (Sec.) Weight Approval & Listings
Number DN BSP Bar Size mm A B C D E kg UL FM CE ATEX
20000609 50 2” 31 33 ± 2 10-25 20-40 35-55 50-70 60-90 3.5 √ √ √ √
20000769 65 2-1 ⁄ 2” 31 33 ± 2 10-25 20-40 35-55 50-70 60-90 3.5 √ √ √ √
20000899 80 3” 31 50 ± 2 10-25 20-40 35-55 50-70 60-90 3.5 √ √ √ √
20001149 100 4” 31 50,8 ± 2 10-25 20-40 35-55 50-70 60-90 3.5 √ √ √ √
20001419 125 5” 31 50,8 ± 2 10-25 20-40 35-55 50-70 60-90 3.5 √ √ √ √
20001689 150 6” 31 50,8 ± 2 10-25 20-40 35-55 50-70 60-90 3.5 √ √ √ √
20002199 200 8” 31 50,8 ± 2 10-25 20-40 35-55 50-70 60-90 3.5 √ √ √ √

Features
Description Specification
Min. Flow 38 L/Min.

IP Rating NEMA 4 / IP66

Temperature +4 / +50° C

2 x SPDT [C]
Contacts 15 A - 125/250 VAC
2 A - 30 VDC

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–9
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Flow Switches
ZONECHECK
Zonecheck Assemblies & Retrofit Kit, Remote Test Unit

Sizes DN50 thru DN150

Approvals FM, VdS, LPCB & CE Approved

Tech Data Sheet Contact Tyco for details

Zonecheck Assemblies & Retrofit Kit


Size Weight Approval & Listings
Part Number
DN kg FM LPCB VdS CE *
ZONECHK50 50 14.3 √ √ √ √
ZONECHK65 65 14.9 √ √ √ √
ZONECHK80 80 16.5 √ √ √ √
ZONECHK100 100 18.7 √ √ √ √
ZONECHK150 150 24.3 √ √ √ √
* CE only on separate parts.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–10
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Pressure Switches
PS10-1 or PS10-2
Pressure Switch

1
Sizes ⁄ 2” NPT

Approvals UL Listed & FM, VdS, LPCB & CE Approved

Tech Data Sheet Contact Tyco for details

Designed to detect a pressure increase or decrease in fire sprinkler systems • PS10 switch is appropriate for water flow detection

PS10-1 or PS10-2 Pressure Switch


Approval & Listings
Part Size Number of P Weight
Model EN Fire Academy
Number NPT SPDT Contacts bar kg UL FM LPCB VdS CE VNIIPO T/S/U PAVUS
Std. of Russia
1
0260 PS10-1 ⁄ 2” 1 17.2 0.58 √ √ √ √ √ √ √ √ √
1
0261 PS10-2 ⁄ 2” 2 17.2 0.62 √ √ √ √ √ √ √ √ √ √

Features
Adjustment Knob Ground Screws
Description Specification
1
Connection ⁄ 2” NPT

Typical Differential 0.13 Bar

Factory Setting 0.27-0.55 Bar 73

Max. Pressure 17.2 Bar 107


IP Rating IP66 1/2"
NPT
NEMA rating NEMA 4

Temperature -40 / + 60°C 63 41


SPDT [C] 96 81
Contacts 10,1 A - 125/250 VAC
2,0 A - 30 VDC
Note: To prevent leakage, apply Teflon tape
sealant to male threads only

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–11
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Pressure Switches
PS40-1 or PS40-2
Pressure Switch

1
Sizes ⁄ 2” NPT

Approvals UL Listed & FM, VdS, LPCB & CE Approved

Tech Data Sheet Contact Tyco for details

PS40-1 or PS40-2 Pressure Switch


Approval & Listings
Part Size Number of P Weight
Model Fire Academy
Number NPT SPDT Contacts bar kg UL FM LPCB VdS CE VNIIPO T/S/U
of Russia
1
262 PS40-1 ⁄ 2” 1 17.2 0.68 √ √ √ √ √ √ √
1
263 PS40-2 ⁄ 2” 2 17.2 0.7 √ √ √ √ √ √ √ √

Features
Description Specification
Adjustment Knob Ground Screws
1
Connection ⁄ 2” NPT

Typical Differential 0.07 at 7 Bar & 0.28 at 4.1 Bar


73
Adjustment Pressure 0.7-4.1 Bar 107
Factory Setting 2.1 Bar
1/2"
Max. Pressure 17.2 Bar NPT
63 41
IP Rating IP66
96 81
NEMA rating NEMA 4

Temperature -40 / + 60°C Note: To prevent leakage, apply Teflon


tape sealant to male threads only
SPDT [C]
Contacts 10,1 A - 125/250 VAC
2,0 A - 30 VDC

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–12
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Pressure Switches
PS100-2
Pressure Switch

1
Sizes ⁄ 2” NPT

Approvals UL Listed & FM, LPCB & CE Approved

Tech Data Sheet Contact Tyco for details

PS100-2 Pressure Switch


Approval & Listings
Part Size Number of P Weight
Model Fire Academy
Number NPT SPDT Contacts bar kg UL FM LPCB CE VNIIPO
of Russia
1
0264 PS100-2 ⁄ 2” 2 20.7 0.70 √ √ √ √ √ √

Features
Adjustment Knob Ground Screws
Description Specification
1
Connection ⁄ 2” NPT

Typical Differential 0.14 at 1.7 Bar & 0.55 at 12.1 Ba


73
Adjustment Pressure 1.7-12.1 Bar

Factory Setting 6.2 Bar


107

Max. Pressure 20.7 Bar

IP Rating IP66
63 41
NEMA rating NEMA 4

Temperature -40 / + 60°C 96 81


SPDT [C]
Contacts 10,1 A - 125/250 VAC Note: To prevent leakage, apply Teflon
2,0 A - 30 VDC tape sealant to male threads only

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–13
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Pressure Switches
PS120-1 or PS120-2
Pressure Switch

1
Sizes ⁄ 2” NPT

Approvals UL Listed & FM, VdS, LPCB & CE Approved

Tech Data Sheet Contact Tyco for details

PS120-1 or PS120-2 Pressure Switch


Approval & Listings
Part Size Number of P Weight
Model Fire Academy
Number NPT SPDT Contacts bar kg UL FM LPCB VdS CE VNIIPO
of Russia
1
0266 PS120-1 ⁄ 2” 1 20.7 0.8 √ √ √ √ √ √
1
0267 PS120-2 ⁄ 2” 2 20.7 0.8 √ √ √ √ √ √ √

Features
Adjustment Knob Ground Screws
Description Specification
1
Connection ⁄ 2” NPT

Typical Differential 0.14 at 1.7 Bar & 0.55 at 12.1 Bar


73
Adjustment Pressure 1.7-12.1 Bar
107
Factory Setting
9.0 Bar
[Pressure Increase]
Factory Setting
7.6 Bar
[Pressure Decrease]
63 41
Max. Pressure 20.7 Bar

IP Rating IP66 96 81

NEMA rating NEMA 4 Note: To prevent leakage, apply Teflon tape


Temperature -40 / + 60°C
sealant to male threads only

SPDT [C]
Contacts 10,1 A - 125/250 VAC
2,0 A - 30 VDC

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–14
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Pressure Switches
FF4-2
Pressure Switch

1
Sizes ⁄ 2” NPT

Approvals VdS & CE Approved

Tech Data Sheet Contact Tyco for details

FF4-2 Pressure Switch


Part Size Size Number of P Weight Approval & Listings
Model
Number NPT G SPDT Contacts bar kg VdS PAVUS CE
1 1
013334200 FF4-2 ⁄ 2” ⁄ 2” 1 20 1.00 √ √ √

Features
Description Specification
Connection G 1 ⁄ 2” Female
103
Max. Differential 0.1 Bar
151
Adjustment Pressure 0.5 - 1.0 Bar 75.5
Factory Setting
-
[Pressure Increase]
Factory Setting
- 14
[Pressure Decrease] 26.5
Max. Pressure 20.0 Bar
40.5 40
IP Rating IP54 5.5 G 1/2 77.5
50
NEMA rating - 84.5
Temperature +4 / + 70°C

SPDT [C]
Contacts 6 A - 220 VAC
6 A - 12 VDC

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–15
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Pressure Switches
PS10-EX or PS40-EX
Explosion Proof Pressure Switch

1
Sizes ⁄ 2” NPT

Approvals UL Listed & FM & CE Approved

Tech Data Sheet Contact Tyco for details

PS10-EX or PS40-EX Explosion Proof Pressure Switch


Part Size Number of P Weight Approval & Listings
Model
Number NPT SPDT Contacts bar kg UL FM CENELEC CE ATEX
1
237EX PS10-EX ⁄ 2” 2 20,68 0.64 √ √ √ √ √
1
238EX PS40-EX ⁄ 2” 2 20,68 0.64 √ √ √ √ √

Features
Specification
Description
PS10-EXF PS40-EXF
1 1
Connection ⁄ 2” NPT ⁄ 2”” NPT

Max. Differential 0.07 Bar 0.14 - 1.38 Bar & 0.34 - 12.07 Bar

Adjustment Pressure 0,27 - 1.3 Bar 0,27 - 1,3 Bar


Factory Setting
0.41 ± 0.07 Bar 3.5 Bar II2G Ex dIIB T6
[Pressure Increase]
Factory Setting
0.35 ± 0.07 Bar 2.1 Bar
[Pressure Decrease]
Max. Pressure 20,7 Bar 20,68 Bar

IP Rating IP66 IP66

NEMA rating 4.9 4.9

Temperature -40 / + 60°C -40 / + 60°C

2x SPDT [C] 2x SPDT [C]


Contacts 15 A - 125/250 VAC 15 A - 125/250 VAC
2.5 A - 30 VDC 2.5 A - 30 VDC

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–16
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Pressure Switches
ADPS-300-1B
Pressure Switches for Controlling Pumps

1
Sizes ⁄4" NPT Female

Approvals UL Listed & CE Approved

Tech Data Sheet Contact Tyco for details

ADPS-300-1B Pressure Switch for Controlling Pumps


Part Adj. Operating Proof Pressure Factory Setting Weight Approval & Listings
Differential Bar
Number Range Bar Bar Bar kg UL CE
1370010 1.73-20.7 0.83 27.6 6.2 4.1 1.2 √ √

Features
Description Specification 1/2” 118
1
Connection ⁄4” NPT Female Thread

Max. Pressure 27.6 Bar

IP Rating IP66

NEMA rating NEMA 4X

Temperature -20 / + 82°C 114


SPDT [C]
15 A - 125 VAC
Contacts
1/8 HP - 125 VAC
1/4 HP - 250 VAC
24

24
86
42
83

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–17
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Pressure Switches
RT
Pressure Switches for Controlling Pumps

3
Sizes ⁄ 8" BSP Male

Approvals CE Approved

Tech Data Sheet Contact Tyco for details

RT Pressure Switch for Controlling Pumps


Part Adj. Operating Differential Proof Pressure Weight Approval & Listings
Number Range Bar Bar Bar kg CE
RT5 4.0 - 17.0 0.3 - 2.5 22 0.8 √
RT200 0.2 - 6.0 0.25 - 1.2 22 0.8 √

Features
Description Specification
Connection 3/8” BSP Male Thread
83
Max. Pressure 22.0 Bar
23
IP Rating IP66

NEMA rating -
100 127
93
Temperature -50 / + 70°C 24

SPDT [C]
Contacts 10 A, 400 VAC Ø5
12W, 220 VDC Ø8.5
74 110

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–18
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Pressure Switches
PUMP BOARD
UK Pump Initiation Boards

Approvals CE Approved

Tech Data Sheet Contact Tyco for details

UK Pump Initiation Boards


Part Switch Control Switch Control Approval & Listings
Switch Type
Number Main Pump Jockey Pump CE
PIB2WAY Single Switch 1x 1x √
PIB3WAY Single Switch 2x 1x √
PIB4WAY Single Switch 3x 1x √
PIB2WAYX2 Double Switch 1x 1x √
PIB3WAYX2 Double Switch 2x 1x √
PIB4WAYX2 Double Switch 3x 1x √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–19
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Pressure Switches
CUSP
Control Unit Sprinkler Pump

Approvals VdS Approved

Tech Data Sheet Contact Tyco for details

CUSP - Control Unit Sprinkler Pump


Part Callout Approval & Listings
Description
Number No. VdS
1 Inlet: 3 ⁄4” Union Female BSP √
2 Ball Valve 1 ⁄ 2” √
CUSP000204
3 Pressure Switch FF4-10 √
4 Pressure Gauge 0-16 Bar 1 ⁄ 2” √
Built according to VdS standards.

4
4
3

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–20
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Supervisory Switches
PCVS
Supervisory Switch

1
Sizes ⁄ 2” NPT

Approvals UL Listed & FM & CE Approved

Tech Data Sheet Contact Tyco for details

PCVS Supervisory Switch


Part Number of Weight Approval & Listings
Model
Number SPDT Contacts kg UL FM CE
221 PCVS-2 2 0.7 √ √ √

Features 120.7 57.2


Description Specification 92.7 50.8
1
Connection ⁄ 2” NPT

IP Rating IP65/IP67
76.2
NEMA rating NEMA 4X/6P

Temperature -40 / + 60°C 132.1

2x SPDT [C] 19.0 21.6 28.4


Contacts 10 A - 125/250 VAC
2 A - 30 VDC 21.6
208.3
30.4
3.0
Rod retracted and
breakaway section removed 39.6

81.3

R od extended

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–21
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Supervisory Switches
OSYSU
Supervisory Switch

Approvals UL Listed & FM & CE Approved

Tech Data Sheet Contact Tyco for details

Used to monitor the open position of an OS&Y (outside screw and yoke) type gate valve • Mounts conveniently to most OS&Y
valves ranging in size from DN50 - DN300 (2" to 12") • Can be used on some valves as small as 1 ⁄ 2" • Models include options for one
or two sets of SPDT (Form C) contacts.

OSYSU Supervisory Switch


Part Number of Weight Approval & Listings
Model
Number SPDT Contacts kg UL FM CE
217 OSYSU-1 1 0.9 √ √ √
218 OSYSU-2 2 0.9 √ √ √

Features 157.2
Description Specification 120.7 76.2
91.9 57.2
IP Rating IP65 / IP67

NEMA rating NEMA 4X/6P

Temperature -40 / + 60°C 76.2

OSYSU-1, SPDT [C]


OSYSU-2, 2x SPDT [C]
Contacts
10 A - 125/250 VAC
2 A - 30 VDC 149.4

22.4
39.6
98.6

R od retracted and
breakaway section removed
R od extended

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–22
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Supervisory Switches
PIVS-U-EX
Explosion Proof Supervisory Switch

1
Sizes ⁄ 2” NPT

Approvals UL Listed Explosion-Proof Switch Enclosure

Tech Data Sheet Contact Tyco for details

PIVS-U-EX Explosion Proof Supervisory Switch


Part Number of Weight
Model
Number SPDT Contacts kg
225-072501 PIVS-U-EX 1 1.50

Features
Description Specification
1
Connection ⁄ 2” NPT

Temperature -40 / + 60°C

Contacts SPDT [C]

II2G Ex dIIC T6

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–23
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Supervisory Switches
OSYS-U-EX
Explosion Proof Supervisory Switch

1
Sizes ⁄ 2” NPT

Approvals UL Listed Explosion-Proof Switch Enclosure

Tech Data Sheet Contact Tyco for details

OSYS-U-EX Explosion Proof Supervisory Switch


Part Number of Weight
Model
Number SPDT Contacts kg
214-072501 OSYS-U-EX 1 0.90

Features
Description Specification
1
Connection ⁄ 2” NPT

Temperature -40 / + 60°C

Contacts SPDT [C]


II2G Ex dIIC T6

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–24
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Monitor Switches
Fig. I88
Monitor Switch

Approvals UL Listed & CE Approved

Tech Data Sheet Contact Tyco for details

Fig. I88 Monitory Switch


Part Weight Approval & Listings
Model
Number kg CE UL
997908 I88 0.07 √ √

Features 10
Description Specification
Connection -
3
IP Rating IP65

NEMA rating -
10

Temperature -30 / + 80°C


85.5
Contacts 10 A - 500 VAC

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–25
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Monitor Switches
BIGGY
Monitor Switch

Approvals UL Listed & CE Approved

Tech Data Sheet Contact Tyco for details

BIGGY Monitory Switch


Part Weight Approval & Listings
Model
Number kg CE UL
999887 BIGGY 0.08 √ √

Features Ø8 10
Description Specification
Connection -
22 20 16
IP Rating IP65

NEMA rating - 61.9


Temperature -30 / + 70°C

Contacts 10 A - 500 VAC

59 32

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–26
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Flow Meters
VENTURI
Flow Meter Butt Weld, Grooved Ends

Sizes DN65 thru DN300

Approvals FM Approved

Tech Data Sheet Contact Tyco for details

VENTURI Flow Meter Butt Weld, Grooved Ends


Required straight Approval &
Part Size Pump Flow Range Dim. Weight
pipe length [mm] Listings
Number Capacity A kg
DN in mm LPM GPM Before After FM
K010000734 65 2-1 ⁄ 2” 73 100 189-757 50-200 101.6 365 146 4 √
K015000894 80 3” 89 150 284-1135 75-300 111.1 445 178 8 √
K020000894 80 3” 89 200 378-1514 100-400 111.1 445 178 8 √
K025001144 100 4” 114.3 250 473-1892 125-500 95.3 570 228 8 √
K030001144 100 4” 114.3 300 567-2271 150-600 95.3 570 228 8 √
K045001144 100 4” 114.3 450 851-3406 225-900 95.3 570 228 8 √
K050001414 125 5” 141.3 500 946-3785 250-1000 127 695 278 8.5 √
K075001684 150 6” 168.3 750 1419-5677 375-1500 152.4 840 336 8.5 √
K100001684 150 6” 168.3 1000 1892-7570 500-2000 152.4 840 336 8.5 √
K125001684 150 6” 168.3 1250 2365-9462 625-2500 152.4 840 336 8.5 √
K150002194 200 8” 219.1 1500 2838-11355 750-3000 177.8 1095 438 10.5 √
K200002194 200 8” 219.1 2000 3785-15140 1000-4000 177.8 1095 438 10.5 √
K250002194 200 8” 219.1 2500 4731-18925 1250-5000 177.8 1095 438 10.5 √
K300002194 200 8” 219.1 3000 5677-22710 1500-6000 177.8 1095 438 10.5 √
K350002734 250 10” 273 3500 6623-26495 1750-7000 203.2 1365 546 13 √
K400002734 250 10” 273 4000 7570-30280 2000-8000 203.2 1365 546 13 √
K450002734 250 10” 273 4500 8516-34065 2250-9000 203.2 1365 546 13 √
K500003244 300 12” 323.9 5000 9462-37850 2500-10000 304.8 1620 648 18 √

GERAND

Metal
Identification
Tag

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–27
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Flow Meters
MAGFLO
Electromagnetic Flow Meters

Sizes DN65 thru DN250 (2-1 ⁄ 2” thru 10")

Approvals VdS & CE Approved

Tech Data Sheet Contact Tyco for details

MAGFLO Electromagnetic Flow Meters


Part Size Retard Settings (Sec.) Flow Flange x Weight Approval & Listings
Number DN in A A1 B D D1 L Range Flange kg CE VdS
MAGFLO0768 65 2-1 ⁄ 2” 212 363 72 185 154 200 0 - 2000 PN16 12 √ √
MAGFLO0898 80 3” 222 373 72 200 174 200 0 - 3000 PN16 12 √ √
MAGFLO1148 100 4” 242 393 85 220 214 250 0 - 4667 PN16 16 √ √
MAGFLO1398 125 5” 255 406 85 250 239 250 0 - 7333 PN16 19 √ √
MAGFLO1688 150 6” 276 427 85 285 282 300 0 - 10600 PN16 27 √ √
MAGFLO2197 200 8” 304 455 137 340 338 350 0 - 18833 PN10 40 √ √
MAGFLO2737 250 10” 332 483 137 395 393 450 0 - 29333 PN10 55 √ √
Required straight pipe length [mm] before: 5D
Required straight pipe length [mm] after: 3D

131 155
Optional equipments
Part
Specification
Number
PG 13.5
MAGFLOBRAC Wall Bracket
A1

MAGFLOCABE Extension Cable A

D1

D B
L

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–28
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Flow Meters
Turbo-Lux3
Flow Meters

Sizes DN50 thru DN200

Approvals FM, LPCB, & VdS Approved

Tech Data Sheet Contact Tyco for details

Model: Turbo-Lux 3 Short Outlet (2xD)


Part Size End PN Weight Approval & Listings
Capacity Temperature
Number DN in Connection bar kg FM LPCB VdS
TL3EBS060G 50 60,3 Grooved 16 20-100GPM / 75-375LPM 50°C 2.0 √ √ √
TL3FCS076G 65 76,1 Grooved 16 40-200GPM / 150-750LPM 50°C 2.1 √ √ √
TL3GDS089G 80 88,9 Grooved 16 60-300GPM / 220-1100LPM 50°C 2.3 √ √ √
TL3GES089G 80 88,9 Grooved 16 80-400GPM / 300-1500LPM 50°C 2.3 √ √ √
TL3HFS114G 100 114,3 Grooved 16 100-500GPM / 380-1900LPM 50°C 3.2 √ √ √
TL3HGS114G 100 114,3 Grooved 16 120-600GPM / 460-2300LPM 50°C 3.2 √ √ √
TL3HHS114G 100 114,3 Grooved 16 160-800GPM / 600-3000LPM 50°C 3.2 √ √ √
TL3HJS114G 100 114,3 Grooved 16 180-900GPM / 680-3400LPM 50°C 3.2 √ √ √
TL3KKS168G 150 168,3 Grooved 16 200-1000GPM / 760-3800LPM 50°C 3.2 √ √ √
TL3KLS168G 150 168,3 Grooved 16 300-1500GPM / 1130-5650LPM 50°C 4.9 √ √ √
TL3KMS168G 150 168,3 Grooved 16 400-2000GPM / 1500-7500LPM 50°C 4.9 √ √ √
TL3LPS219G 200 219,1 Grooved 16 600-3000GPM / 2200-11000LPM 50°C 6.4 √ √ √
TL3LQS219G 200 219,1 Grooved 16 800-4000GPM / 3000-15000LPM 50°C 6.4 √ √ √

Model: Turbo-Lux 3 - Scale Graduation


Nominal Size Pump Rating Flow Range Step Graduation Flow Range Step Graduation
DN in (GPM) (GPM) (GPM) (GPM) (Lpm) (Lpm) (Lpm)
50 2" 50 20 - 100 10 5 75 - 375 50 5
65 2-1 ⁄ 2” 100 40 - 200 20 4 150 - 750 100 5
80 3" 150 60 - 300 50 5 220 - 1.100 200 4
80 3" 200 80 - 400 50 5 300 - 1.500 200 4
100 4" 250 100 - 500 50 5 380 - 1.900 200 4
100 4" 300 120 - 600 100 5 460 - 2.300 200 4
100 4" 400 160 - 800 100 5 600 - 3.000 500 5
100 4" 450 180 - 900 100 5 680 - 3.400 500 5
150 6" 500 200 - 1.000 100 5 760 - 3.800 500 5
150 6" 750 300 - 1.500 200 4 1.130 - 55.650 1.000 5
150 6" 1.000 400 - 2.000 200 4 1.500 - 7.500 1.000 5
150 6" 1.250 500 - 2.500 500 5 1.900 - 9.500 1.000 5
200 8" 1.500 600 - 3.000 500 5 2.200 - 11.000 2.000 4
200 8" 2.000 800 - 4.000 500 5 3.000 - 15.000 2.000 4
200 8" 2.500 1.000 - 5.000 1.000 5 3.800 - 19.000 2.000 4
200 8" 3.000 1.200 - 6.000 1.000 5 4.500 - 22.500 2.000 4

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–29
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Flow Meters
INFLUX
Flow Meters

Sizes DN50 thru DN200 (2" thru 8")

Approvals FM & LPCB Approved

Tech Data Sheet Contact Tyco for details

INFLUX Flow Meters


Part Size Straight Pipe F-F Approval & Listings
Type Flow
Number DN in before & after mm FM LPCB
F3/1 50 2” Wafer 150-700 LPM 250 40 √
F3/2 80 3” Wafer 300-1600 LPM 400 40 √
F3/3 100 4” Wafer 500-3500 LPM 500 40 √
F3/4 150 6” Wafer 900-7900 LPM 750 40 √
F3/5 200 8” Wafer 2000-15000 LPM 1000 40 √
F3/6 50 2” Grooved 150-700 LPM 250 90 √
F3/7 80 3” Grooved 300-1600 LPM 400 90 √
F3/8 100 4” Grooved 500-3500 LPM 500 90 √
F3/9 150 6” [165.1mm] Grooved 900-7900 LPM 750 90 √
F3/9 FM 150 6” [168.3mm] Grooved 1000-7500LPM 750 90 √
F3/10 200 8” Grooved 2000-15000 LPM 1000 100 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–30
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Water Tank Equipment
FST-A
Water Tank Equipment Water Level Indicator for Air Pressurized Water Tank, Type A

Approvals VdS Approved

Tech Data Sheet Contact Tyco for details

FST-A - Water Level Indicator for Air Pressurized Water Tank, Type A
Part Callout Approval & Listings
Description
Number No. VdS
1 Ball Valve 1 ⁄ 2” √
2 Pressure Gauge 0-16 Bar 1 ⁄ 2” √
FSTA021AGR 3 Level Indicator Pipe PN10 Ø12 mm, Length 480 mm
4 Protection Tube, Length 450 mm √
5 Union 1” Female √
Built according to VdS standards.

2
5

3
4 1

1 2
5

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–31
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Water Tank Equipment


FST-B
Water Tank Equipment Water Level Indicator for Air Pressurized Water Tank, Type B

Approvals VdS Approved

Tech Data Sheet Contact Tyco for details

FST-B - Water Level Indicator for Air Pressurized Water Tank, Type B
Part Call out Approval & Listings
Description
Number No. VdS
1 Ball Valve 1 ⁄ 2” √
2 Pressure Gauge 0-16 Bar 1 ⁄ 2” √
3 Level Indicator Pipe PN10 Ø12 mm, Length 480 mm √
4 Protection Tube, Length 450 mm √
FSTA021BGR
5 Unions 1” BSP Male √
6 Valve with Test Flange 1 ⁄ 2”” √
7 Float Switch 1” BSP √
8 Pressure Switch FF4-10 1 ⁄ 2” √

1
5
3
6
4 7
4

5
2
1

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–32
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Water Tank Equipment
FEEDING TANK
Feeding Tank Hot Dip Galvanized

Volume 100L, 200L & 500L

Approvals UL Listed & FM & CE Approved

Tech Data Sheet Contact Tyco for details

FEEDING TANK Feeding Tank Hot Dip Galvanized


Part Dimension mm Weight
Volume
Number L B H kg
TANK100WOV 100 l. 1000 400 425 45
TANK200WOV 200 l. 1100 450 530 52
TANK500WOV 500 l. 1500 550 500 110

Float Valve
Part Weight
DN Description
Number kg
Float Valve including
FLOAT00340 25 1.4
Float Ball, BSP Ma
H

L
B

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–33
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Water Tank Equipment


FLOAT SWITCH
Float Switch for Level Regulations and Pump Control

Length 0.5m thru 20m

Tech Data Sheet Contact Tyco for details

FLOAT SWITCH - Float Switch for Level Regulations and Pump Control
Part Cable Length MA x T
Cable
Number [m] °C
19000500 0.5 50 3 x 1 mm2, max. 10A
19020000 2 50 3 x 1 mm2, max. 10A
19030000 3 50 3 x 1 mm2, max. 10A
19050000 5 50 3 x 1 mm2, max. 10A
19100000 10 50 3 x 1 mm2, max. 10A
19150000 15 50 3 x 1 mm2, max. 10A
19200000 20 50 3 x 1 mm2, max. 10A

FEEDING DEVICE
Water Tank Equipment
Water: 1-1 ⁄ 2”
Sizes
Air: 3 ⁄4"

Approvals VdS Approved

Tech Data Sheet Contact Tyco for details

FEEDING DEVICE - Water Tank Equipment


Part Approval & Listings
Description
Number VdS *
WE048DLWKG Water feeding Device 1-1 ⁄ 2” √
LE027DLWKG Air feeding Device 3 ⁄4” √
*When combined with VdS approved valve

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–34
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Water Tank Equipment
PROVING PIPES
Water Supplies Proving Equipment

Malleable Iron, Galvanized,


Body
Mild Steel, Noryl, ABS

Approvals LPCB listed in combination with BW valve only.

AS. 128
Tech Data Sheet
Contact Tyco for details

PROVING PIPES - Water Supplies Proving Equipment


Approval &
Part Inlet BSP Outlet BSP Gauge Readings Weight
Hazzard Group Listings
Number Male Female kg
1st 2nd LPCB
01308 XLH 3” 3” 275 - 7 √
01309 OH1 3” 3” 375 540 7 √
01310 OH2 3” 3” 725 1000 7 √
01311 OH3 3” 3” 1100 1350 7 √
01312 OH3 Special 3” 3” 1800 2100 7 √
01313 XHH 7.5 mm/min 3” 3” 2300 - 7 √
01333 XHH 10 mm/min 3” 3” 3050 - 7 √

143

400

608 106

200

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–35
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Water Tank Equipment


GAUGE
Water Supplies Proving Equipment

Approvals UL Listed & FM Approved

Tech Data Sheet Contact Tyco for details

Other options available on request

GAUGE - Water Supplies Proving Equipment


Part Dimensions mm Weight Approval & Listings
Connection Meter Range Type Material
Number D B kg UL FM
1
25500013 ⁄4” NPT 0-400 Psi Dry Black 94 46 0.4 √
1
923431012 ⁄4” NPT 0-300 Psi Dry ABS 94 29 0.15 √ √
3
2135338 ⁄ 8” ISO 0-16 Bar Glycerin St. Steel 100 46 0.35
1
7125411 ⁄ 2” ISO 0-16 Bar Dry Steel 100 46 0.4
1
7125411G ⁄ 2” ISO 0-16 Bar Glycerin St. Steel 100 46 0.8
7125411G63 1/4” ISO 0-16 Bar Glycerin St. Steel 63 46 0.8
1
7125438 ⁄ 2” ISO 0-16 Bar Dry Steel 100 46 0.4
1
7125454 ⁄4” NPT 0-10 Bar Dry Steel 100 46 0.4
1
2161086 ⁄ 2” ISO -1-3 Bar Glycerin St. Steel 100 50 0.8
1
W01000110 ⁄ 2” ISO 0-25 Bar Dry Steel 100 46 0.4
1
9296808* ⁄ 2” ISO 0-16 Bar Dry Steel 100 46 0.6
*Gauge also includes pressure switch

D B

Conn.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–36
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Water Tank Equipment
MAXANTKIT
Pressure Reading Equipment

1
Sizes ⁄ 2” BSP

Tech Data Sheet Contact Tyco for details

Maxant - Pressure Reader


Part P
Connection DN Adjustment Range Voltage Accuracy
Number max
1
MAXANTKIT ⁄ 2” BSP 100, 150, 200 16 Bar 1 day, 7days 1.5 V Battery ±1% Pmax

Parts List
Item Part
Quantity
No. Number
1 1 2111000
2 1 406012 15
3 1 59304FO 1
4 5 713700 6
5 2 933512X25
6 2 93356X20 12
7 1 A133D2 20
8 1 A245DB2 14
9 1 A270D2
10 1 A280D2 5 13
11 1 A290D2
12 2 MCF2F
13 2 PNP06ZP
14 2 PNP12AZP
15 1 REF48
16 1 SS2/KH
17 1 SS2/MH
7
18 1 SS2/NH 3
19 1 WS00000004 10
20 1 WS00000035 11 2
19 9
4
Spare Parts 8
Part Number Description
Maxant Pressure
REF48*
Reader
Paperband
251200016
[100 pages]
Pen
552700001
[min. order 5 pcs.]
*Includes 251200016 and 552700001

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 5–37
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Water Tank Equipment


PBA-AC
Electric Bells

Sound 87 - 99 dB

Approvals UL Listed & FM Approved

Tech Data Sheet Contact Tyco for details

PBA-AC - Electric Bells


Part Current Weight Approval & Listings
ØD Model Voltage dB 3 mtrs.
Number [max.] A kg UL FM
25001680 152 PBA246 24 VAC 0.17 91 1.2 √ √
25001681 152 PBA1206 120 VAC 0.05 92 1.2 √ √
25002190 203 PBA248 24 VAC 0.17 94 1.2 √ √
25002191 203 PBA1208 120 VAC 0.05 99 1.2 √ √
25002730 254 PBA2410 24 VAC 0.17 94 1.2 √ √
25002731 254 PBA12010 120 VAC 0.05 99 1.2 √ √

254
203 146 86 127
152

41 86
108
68

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

5–38
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Tyco CPVC Pipe & Fittings
Manufactured with BlazeMaster® compound.

- Light Hazard & Residential - Connections to Copper


Occupancies & Steel Piping

- Unfinished basements - Resistance of Sweating,


Condensation, & MIC
- Underground Water
Pressure Service

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-1
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC Pipe
Sprinkler Pipe
Sizes DN20 thru DN80 (3 ⁄4" thru 3")

Pipe Length 3.05m (10’) Lengths

UL, C-UL Listed & FM, MEA, NSF,


Approvals
Fire Academy of Russia, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC pipe is designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC pipe is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC piping materials. • TYCO CPVC sprinkler pipe conforms to the requirements of ASTM F442 and is produced to SDR 13.5.
SDR (Standard Dimension Ratio) is the ratio of the outside pipe diameter to the wall thickness of the pipe.

CPVC Pipe
Size Approval Listings
OD ID Length Weight Fire
Part No.
DN In. mm mm m kg LPCB FM UL MEA NSF Academy
of Russia
3
80300T 20 ⁄4 ” 26.7 22.7 3.05 0.6 √ √ √ √ √ √
80301T 25 1” 33.4 28.5 3.05 0.9 √ √ √ √ √ √
80302T 32 1-1 ⁄4” 42.1 35.9 3.05 1.4 √ √ √ √ √ √
80303T 40 1-1 ⁄ 2” 48.3 41.1 3.05 1.8 √ √ √ √ √ √
80304T 50 2” 60.3 51.4 3.05 2.9 √ √ √ √ √ √
80305T 65 2-1 ⁄ 2” 73.0 62.2 3.05 2.9 √ √ √ √ √
80306T 80 3” 88.9 75.7 3.05 6.3 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-2
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings
CPVC Fittings

45° Elbow
Sizes DN20 thru DN80 (3 ⁄4" thru 3" )

Approvals UL, C-UL Listed & FM, MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

T/O

B
A

CPVC 45° Elbow


Size A H T/O Weight Approval Listings
Part No.
DN In. mm mm mm kg LPCB FM UL MEA NSF
3
80050 20 ⁄4 ” 33 30 9 0.036 √ √ √ √ √
80051 25 1” 40 33 9 0.050 √ √ √ √ √
80052 32 1-1 ⁄4” 50 47 20 0.091 √ √ √ √ √
80053 40 1-1 ⁄ 2” 59 48 12 0.141 √ √ √ √ √
80054 50 2” 72 59 19 0.254 √ √ √ √ √
90055 65 2-1 ⁄ 2” 89 62 19 0.404 √ √ √ √ √
90056 80 3” 106 75 25 0.504 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-3
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC Fittings
90° Elbow
Sizes DN20 thru DN80 (3 ⁄4" thru 3" )

Approvals UL, C-UL Listed & FM, MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

T/ O

B A

CPVC 90° Elbow


Size A H T/O Weight Approval Listings
Part No.
DN In. mm mm mm kg LPCB FM UL MEA NSF
3
80025 20 ⁄4 ” 33 36 16 0.041 √ √ √ √ √
80026 25 1” 40 43 19 0.063 √ √ √ √ √
80027 32 1-1 ⁄4” 50 50 23 0.095 √ √ √ √ √
80028 40 1-1 ⁄ 2” 59 62 27 0.181 √ √ √ √ √
80029 50 2” 72 74 33 0.358 √ √ √ √ √
80030 65 2-1 ⁄ 2” 87 85 39 0.517 √ √ √ √ √
80031 80 3” 105 95 46 0.825 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-4
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings
CPVC Fittings
90° Reducing Elbow
Sizes DN25 x DN20 (1" x 3 ⁄4")

Approvals UL, C-UL Listed & FM, MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

T/O 2

B A
1
T/O
H

D
C

CPVC 90° Reducing Elbow


B D A C H T/O1 T/O2 Weight Approval Listings
Part No.
DN In. DN In. mm mm mm mm mm kg LPCB FM UL MEA NSF
3
80032 25 1” 20 ⁄4 ” 40 40 41 1 17 0.073 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-5
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC Fittings
Tee Equal
Sizes DN20 thru DN80 (3 ⁄4" thru 3" )

Approvals UL, C-UL Listed & FM, MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

G
T/O

A B

CPVC Tee Equal


Size A H G T/O Weight Approval Listings
Part No.
DN In. mm mm mm mm kg LPCB FM UL MEA NSF
3
80000 20 ⁄4 ” 33 36 72 16 0.05 √ √ √ √ √
80001 25 1” 40 40 81 18 0.086 √ √ √ √ √
80002 32 1-1 ⁄4” 50 48 95 22 0.118 √ √ √ √ √
80003 40 1-1 ⁄ 2” 59 62 125 27 0.231 √ √ √ √ √
80004 50 2” 72 75 150 36 0.408 √ √ √ √ √
80005 65 2-1 ⁄ 2” 87 86 171 39 0.721 √ √ √ √ √
80006A 80 3” 105 95 191 46 1.093 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-6
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings
CPVC Fittings
Cross Equal
Sizes DN20 thru DN80 (3 ⁄4" thru 3" )

Approvals UL, C-UL Listed & FM, MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

G
T/O

A
T/O

CPVC Cross Equal


Size A G T/O Weight Approval Listings
Part No.
DN In. mm mm mm kg LPCB FM UL MEA NSF
3
80009 20 ⁄4 ” 33 70 15 0.059 √ √ √ √ √
80010 25 1” 40 84 18 0.104 √ √ √ √ √
80011A 32 1-1 ⁄4” 50 95 23 0.154 √ √ √ √ √
80012 40 1-1 ⁄ 2” 59 125 27 0.304 √ √ √ √ √
80013 50 2” 72 145 33 0.454 √ √ √ √ √
80014A 65 2-1 ⁄ 2” 89 171 39 0.866 √ √ √ √ √
80008A 80 3” 106 192 46 1.311 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-7
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC Fittings
Reducing Cross
Sizes DN25 x DN25 DN20 x DN20 (1" x 1" x 3 ⁄4" x 3 ⁄4")

Approvals UL, C-UL Listed & FM, MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

G
T/O1

T/O 2
A B

D
C

CPVC Reducing Cross


B D A C G H T/O1 T/O2 Weight Approval Listings
Part No.
DN In. DN In. mm mm mm mm mm mm kg LPCB FM UL MEA NSF
3
80015A 25 1” 20 ⁄4 ” 40 40 84 42 18 22 0.127 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-8
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings
CPVC Fittings
Coupling Equal
Sizes DN20 thru DN80 (3 ⁄4" thru 3" )

Approvals UL, C-UL Listed & FM, MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

G
T/O

A B

CPVC Coupling Equal


Size A G T/O Weight Approval Listings
Part No.
DN In. mm mm mm kg LPCB FM UL MEA NSF
3
80075 20 ⁄4 ” 33 54 3 0.032 √ √ √ √ √
80076 25 1” 40 64 3 0.05 √ √ √ √ √
80077 32 1-1 ⁄4” 50 56 4 0.054 √ √ √ √ √
80078 40 1-1 ⁄ 2” 59 78 5 0.113 √ √ √ √ √
80079 50 2” 72 84 5 0.172 √ √ √ √ √
80080 65 2-1 ⁄ 2” 87 98 6 0.304 √ √ √ √ √
80081 80 3” 105 108 5 0.413 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-9
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC Fittings
Reducing Coupling
Sizes DN25 x DN20 (1" x 3 ⁄4")

Approvals UL, C-UL Listed & FM,MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

G
T/O

A B D C

CPVC Reducing Coupling


B D A C H T/O1 T/O2 Weight Approval Listings
Part No.
DN In. DN In. mm mm mm mm mm kg LPCB FM UL MEA NSF
3
80032 25 1” 20 ⁄4 ” 40 40 41 1 17 0.073 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-10
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings
CPVC Fittings
End Cap
Sizes DN20 thru DN80 (3 ⁄4" thru 3" )

Approvals UL, C-UL Listed & FM, MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

B A

T/O

CPVC End Cap


Size A G T/O Weight Approval Listings
Part No.
DN In. mm mm mm kg LPCB FM UL MEA NSF
3
80100 20 ⁄4 ” 33 28 7 0.018 √ √ √ √ √
80101 25 1” 40 33 10 0.027 √ √ √ √ √
80102 32 1-1 ⁄4” 50 45 10 0.045 √ √ √ √ √
80103 40 1-1 ⁄ 2” 59 56 18 0.091 √ √ √ √ √
80104 50 2” 72 57 15 0.141 √ √ √ √ √
80105 65 2-1 ⁄ 2” 87 70 22 0.263 √ √ √ √ √
80106 80 3” 105 76 24 0.400 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-11
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC Fittings
Reducing Tee
DN20 x DN25 x DN20 thru DN80 x DN65 x DN80
Sizes
(3 ⁄4" x 1" x 3 ⁄4" thru 3" x 2-1 ⁄ 2" x 3")

Approvals UL, C-UL Listed & FM, MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

G
1
T/O T/O2

B D
T/O3
H

CPVC Reducing Tee, Slip x Slip x Slip


Size Approval Listings
G H T/O1 T/O2 T/O3 Weight
Part No. DN In.
mm mm mm mm mm kg LPCB FM UL MEA NSF
B F D B F D
3 3
80132 20 25 20 ⁄4 ” 1” ⁄4 ” 73 38 18 18 15 0.063 √ √ √ √ √
3 3
80133 25 20 20 1” ⁄4 ” ⁄4 ” 71 38 15 15 19 0.063 √ √ √ √ √
3
80134 25 25 20 1” 1” ⁄4 ” 78 41 19 18 18 0.077 √ √ √ √ √
3
80260 25 20 25 1” ⁄4 ” 1” 79 40 15 15 20 0.073 √ √ √ √ √
80135 32 20 25 1-1 ⁄4” 3
⁄4 ” 1” 85 43 16 15 24 0.095 √ √ √ √ √
80136 32 25 25 1-1 ⁄4” 1” 1” 84 45 19 19 23 0.100 √ √ √ √ √
80137 32 32 25 1-1 ⁄4” 1-1 ⁄4” 1” 92 46 23 23 22 0.118 √ √ √ √ √
80261 32 20 32 1-1 ⁄4” 3
⁄4 ” 1-1 ⁄4” 82 43 16 16 23 0.104 √ √ √ √ √
80262 32 25 32 1-1 ⁄4” 1” 1-1 ⁄4” 89 46 19 19 23 0.118 √ √ √ √ √
80138 32 40 32 1-1 ⁄4” 1-1 ⁄ 2” 1-1 ⁄4” 119 63 26 26 26 0.195 √ √ √ √ √
80140 40 20 32 1-1 ⁄ 2” 3
⁄4 ” 1-1 ⁄4” 100 53 15 15 26 0.163 √ √ √ √ √
80141 40 25 32 1-1 ⁄ 2” 1” 1-1 ⁄4” 100 57 15 15 27 0.172 √ √ √ √ √
80263 40 20 40 1-1 ⁄ 2” 3
⁄4 ” 1-1 ⁄ 2” 103 53 15 15 24 0.163 √ √ √ √ √
80264 40 25 40 1-1 ⁄ 2” 1” 1-1 ⁄ 2” 103 58 15 15 27 0.172 √ √ √ √ √
80275 40 32 40 1-1 ⁄ 2” 1-1 ⁄4” 1-1 ⁄ 2” 118 59 22 22 26 0.204 √ √ √ √ √
3
80265 50 20 50 2” ⁄4 ” 2” 116 62 19 19 35 0.277 √ √ √ √ √
80266 50 25 50 2” 1” 2” 123 66 22 22 35 0.299 √ √ √ √ √
80274 50 32 50 2” 1-1 ⁄4” 2” 132 69 26 26 36 0.336 √ √ √ √ √
80267 50 40 50 2” 1-1 ⁄ 2” 2” 137 71 29 29 35 0.354 √ √ √ √ √
80271 65 25 65 2-1 ⁄ 2” 1” 2-1 ⁄ 2” 171 70 39 39 39 0.649 √ √ √ √ √
80272 65 32 65 2-1 ⁄ 2” 1-1 ⁄4” 2-1 ⁄ 2” 171 73 39 39 40 0.662 √ √ √ √ √
80273 65 40 65 2-1 ⁄ 2” 1-1 ⁄ 2” 2-1 ⁄ 2” 171 75 39 39 39 0.671 √ √ √ √ √
80276 65 50 65 2-1 ⁄ 2” 2” 2-1 ⁄ 2” 171 80 39 39 40 0.680 √ √ √ √ √
80270 80 40 80 3” 1-1 ⁄ 2” 3” 191 83 46 46 46 1.034 √ √ √ √
80268 80 50 80 3” 2” 3” 191 85 46 46 46 1.021 √ √ √ √
80269 80 65 80 3” 2-1 ⁄ 2” 3” 191 92 46 46 46 1.107 √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-12
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings
CPVC Fittings
Bush Reducing, Spigot x Slip
DN20 x DN25 thru DN80 x DN65
Sizes
(3 ⁄4" x 1" thru 3" x 2-1 ⁄ 2")

Approvals UL, C-UL Listed & FM, MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

G
T/O

D B A

CPVC Bush Reducing, Spigot x Slip


Size Approval Listings
A G T/O Weight
Part No. DN In.
mm mm mm kg LPCB FM UL MEA NSF
D B D B
3
80200 25 20 1” ⁄4 ” 38 30 11 0.018 √ √ √ √ √
80201 32 20 1-1 ⁄4” 3
⁄4 ” 47 32 12 0.050 √ √ √ √ √
80202 32 25 1-1 ⁄4” 1” 47 32 8 0.054 √ √ √ √ √
80203 40 20 1-1 ⁄ 2” 3
⁄4 ” 53 42 15 0.072 √ √ √ √ √
80204 40 25 1-1 ⁄ 2” 1” 53 42 12 0.063 √ √ √ √ √
80205 40 32 1-1 ⁄ 2” 1-1 ⁄4” 53 42 9 0.077 √ √ √ √ √
3
80206 50 20 2” ⁄4 ” 66 47 20 0.122 √ √ √ √ √
80207 50 25 2” 1” 66 47 17 0.118 √ √ √ √ √
80208 50 32 2” 1-1 ⁄4” 66 47 14 0.109 √ √ √ √ √
80209 50 40 2” 1-1 ⁄ 2” 66 47 11 0.086 √ √ √ √ √
80215 65 25 2-1 ⁄ 2” 1” 79 54 24 0.190 √ √ √ √ √
80214 65 32 2-1 ⁄ 2” 1-1 ⁄4” 79 54 20 0.204 √ √ √ √ √
80213 65 40 2-1 ⁄ 2” 1-1 ⁄ 2” 79 54 18 0.209 √ √ √ √ √
80211 65 50 2-1 ⁄ 2” 2” 79 54 15 0.152 √ √ √ √ √
80210 80 50 3” 2” 96 59 20 0.387 √ √ √ √ √
80212 80 65 3” 2-1 ⁄ 2” 96 59 13 0.213 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-13
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC Fittings
Coupling Adaptor, Slip x Groove
Sizes DN32 thru DN80 (1-1 ⁄4" thru 3")

Approvals UL, C-UL Listed & FM, MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

A B C OD

H T/O

CPVC Coupling Adaptor, Slip x Groove


Size Approval Listings
A G H T/O Weight
Part No. DN In.
mm mm mm mm kg LPCB FM UL MEA NSF
D B D B
80160 32 1-1 ⁄4” 32 42.2 52 93 34 59 0.354 √ √ √ √ √
80161 40 1-1/2” 40 48.3 59 95 37 58 0.431 √ √ √ √ √
80162 50 2” 50 60.3 72 98 40 58 0.644 √ √ √ √ √
80163 65 2-1/2” 65 73.0 87 107 49 58 1.034 √ √ √ √ √
80169 65 2-1/2” 65 76.1 91 107 49 58 1.155 √ √ √ √ √
80164 80 3” 80 88.9 105 110 52 58 1.361 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-14
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings
CPVC Fittings
Male Threaded Adaptor, Slip x Male Thread
Sizes DN20 thru DN25 (3 ⁄4" thru 1")

Approvals UL, C-UL Listed & FM, MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

A B

T/O
CPVC Male Threaded Adaptor, Slip x Male Thread
Size Approval Listings
A G H T/O Weight
Part No. DN In.
mm mm mm mm kg LPCB FM UL MEA NSF
D B D B
3 3
80157 20 ⁄4 ” 20 ⁄4” NPT 33 72 25 33 0.15 √ √ √ √ √
80158 25 1” 25 1” NPT 40 84 32 35 0.254 √ √ √ √ √
82005 25 1” 25 1” BSP 40 84 32 35 0.254 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-15
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC Fittings
Female Threaded Adaptor, Slip x Female Thread
Sizes DN20 thru DN50 (3 ⁄4" thru 2")

Approvals UL, C-UL Listed & FM, MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

G
H

A B C

T/O

CPVC Female Threaded Adaptor, Slip x Female Thread


Size Approval Listings
A C G H T/O Weight
Part No. B Nominal D Threaded
mm mm mm mm mm kg LPCB FM UL MEA NSF
DN In. DN In.
3 3
80142 20 ⁄4 ” 20 ⁄4” NPT 35 43 61 27 21 0.186 √ √ √ √ √
80145 25 1” 25 1” NPT 43 52 69 30 23 0.286 √ √ √ √ √
80146 32 1-1 ⁄4” 32 1-1 ⁄4” NPT 52 61 79 34 28 0.467 √ √ √ √ √
80147 40 1-1 ⁄ 2” 40 1-1 ⁄ 2” NPT 59 67 87 36 34 0.644 √ √ √ √ √
80148 50 2” 50 2” NPT 72 88 100 40 43 1.207 √ √ √ √ √
82001 25 1” 25 1” BSP 43 52 69 30 23 0.286 √ √ √ √ √
82002 32 1-1 ⁄4” 32 1-1 ⁄4” BSP 52 61 79 34 28 0.467 √ √ √ √ √
82003 40 1-1 ⁄ 2” 40 1-1 ⁄ 2” BSP 59 67 87 36 34 0.644 √ √ √ √ √
82004 50 2” 50 2” BSP 72 88 100 40 43 1.207 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-16
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings
CPVC Fittings
Sprinkler Head Adaptor, Slip x Female Thread, Type E
Sizes DN20 x DN15 & DN25 x DN15 (3 ⁄4" x 1 ⁄ 2" & 1" x 1 ⁄ 2")

Approvals UL, C-UL Listed & FM, MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

G
H

A B D E

T/O

CPVC Sprinkler Head Adaptor, Slip x Female Thread, Type E


Size Approval Listings
A C G H T/O Weight
Part No. B Nominal D Threaded
mm mm mm mm mm kg LPCB FM UL MEA NSF
DN In. DN In.
3 1
80175E 20 ⁄4 ” 15 ⁄ 2” NPT 35 43 52 28 12 0.091 √ √ √ √ √
1
80176E 25 1” 15 ⁄ 2” NPT 43 43 56 31 12 0.1 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-17
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC Fittings
Sprinkler Head Adaptor, Slip x Female Thread, Type W
Sizes DN20 x DN15 & DN25 x DN15 (3 ⁄4" x 1 ⁄ 2" & 1" x 1 ⁄ 2")

Approvals UL, C-UL Listed & FM, MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

A B D

T/O

CPVC Sprinkler Head Adaptor, Slip x Female Thread, Type W


Size Approval Listings
A G H T/O Weight
Part No. B Nominal D Threaded
mm mm mm mm kg LPCB FM UL MEA NSF
DN In. DN In.
3 1
80175W 20 ⁄4 ” 15 ⁄ 2” 41 44 19 12 0.086 √ √ √ √ √
1
80176W 25 1” 15 ⁄ 2” 40 49 25 12 0.082 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-18
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings
CPVC Fittings
Sprinkler Head Adaptor, Slip x Female Thread, Type WL
Sizes DN20 x DN15 & DN25 x DN20 (3 ⁄4" x 1 ⁄ 2" & 1" x 3 ⁄4")

Approvals UL, C-UL Listed & FM, MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

G
H

A B D C

T/O

CPVC Sprinkler Head Adaptor, Slip x Female Thread, Type WL


Size Approval Listings
A C G H T/O Weight
Part No. B Nominal D Threaded
mm mm mm mm mm kg LPCB FM UL MEA NSF
DN In. DN In.
3 1
80175WL 20 ⁄4 ” 15 ⁄ 2” NPT 33 33 44 20 11 0.073 √ √ √ √ √
3
80179 25 1” 20 ⁄4” NPT 43 43 64 30 11 0.195 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-19
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC Fittings
Sprinkler Head Adaptor, Spigot x Female Thread
DN20 x DN15 thru DN25 x DN20
Sizes
(3 ⁄4" x 1 ⁄ 2" thru 1" x 3 ⁄4")

Approvals UL, C-UL Listed & FM,MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

B D C

T/O

CPVC Sprinkler Head Adaptor, Spigot x Female Thread


Size Approval Listings
C G H T/O Weight
Part No. B Nominal D Threaded
mm mm mm mm kg LPCB FM UL MEA NSF
DN In. DN In.
3 1
80177L 20 ⁄4 ” 15 ⁄ 2” NPT 34 45 19 13 0.073 √ √ √ √ √
1
80178 25 1” 15 ⁄ 2” NPT 43 49 22 14 0.091 √ √ √ √ √
1
⁄ 2” NPT
80178X 25 1” 15 43 58 31 16 0.090 √ √ √ √ √
Extended
3
80180 25 1” 20 ⁄4” NPT 43 57 22 22 0.180 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-20
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings

CPVC Fittings

Sprinkler Head Tee, Slip x Female Thread x Slip


DN20 x DN15 x DN20 thru DN50 x DN15 x DN50
Sizes
(3 ⁄4" x 1 ⁄ 2" x 3 ⁄4" thru 2" x 1 ⁄ 2" x 2")

Approvals UL, C-UL Listed & FM, MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

T/O T/O3
1

A B D C

H T/O3

F
CPVC Sprinkler Head Tee, Slip x Female Thread x Slip
Size Approval Listings
A C G H T/O1 T/O2 T/O3 Weight
Part No. DN In.
mm mm mm mm mm mm mm kg LPCB FM UL MEA NSF
B F D B F D
3 1 3
80250 20 15 20 ⁄4 ” ⁄ 2” NPT ⁄4 ” 33 33 69 38 14 14 25 0.100 √ √ √ √ √
1
80251 25 15 25 1” ⁄ 2” NPT 1” 40 40 83 46 18 18 36 0.131 √ √ √ √ √
80252 32 15 32 1-1 ⁄4” 1
⁄ 2” NPT 1-1 ⁄4” 50 50 76 46 11 11 33 0.141 √ √ √ √ √
80256 32 15 25 1-1 ⁄4” 1
⁄ 2” NPT 1” 50 40 76 46 11 14 33 0.136 √ √ √ √ √
80249 25 25 25 1” 1” NPT 1” 40 40 93 56 23 23 40 0.331 √ √ √ √ √
80259 * 25 25 25 1” 1” NPT 1” 42 42 94 36 23 23 22 0.320 √ √ √ √ √
80257 40 15 40 1-1 ⁄ 2” 1
⁄ 2” NPT 1-1 ⁄4” 59 52 98 49 12 17 36 0.195 √ √ √ √ √
80254 40 15 40 1-1 ⁄ 2” 1
⁄ 2” NPT 1-1 ⁄ 2” 59 59 98 49 12 12 36 0.209 √ √ √ √ √
1
80258 50 15 50 2” ⁄ 2” NPT 1-1 ⁄ 2” 72 59 104 55 12 16 43 0.254 √ √ √ √ √
1
80253 50 15 50 2” ⁄ 2” NPT 2” 72 72 104 55 13 13 42 0.281 √ √ √ √ √
* Used for Dry Sprinklers

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-21
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC Fittings
Sprinkler Head Adaptor, 90° Elbow, Slip x Female Thread
DN20 x DN15 thru DN25 x DN20
Sizes
(3 ⁄4" x 1 ⁄ 2" thru 1" x 3 ⁄4")

Approvals UL, C-UL Listed & FM,MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

G
1
T/O

B A

T/O2
H

CPVC Sprinkler Head Adaptor 90° Elbow, Slip x Female Thread


Size Approval Listings
A G H T/O1 T/O2 Weight
Part No. B Nominal D Threaded
mm mm mm mm mm kg LPCB FM UL MEA NSF
DN In. DN In.
3 1
80199 20 ⁄4 ” 15 ⁄ 2” NPT 33 35 38 14 25 0.091 √ √ √ √ √
1
80198 25 1” 15 ⁄ 2” NPT 40 40 44 18 31 0.118 √ √ √ √ √
3
80196 25 1” 20 ⁄4” NPT 45 51 49 27 37 0.120 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-22
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings
CPVC Fittings

Back-to-Back Sprinkler Head Tee, Slip x Female Thread x Female Thread


Sizes DN25 DN15 (1" x 1 ⁄ 2")

Approvals UL, C-UL Listed & FM, MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

T/O1 T/O1

D
T/O2

B
A

CPVC Back-to-Back Sprinkler Head Tee, Slip x Female Thread x Female Thread
Size Dry Approval Listings
A G H T/O1 T/O2 Weight
Part No. B Nominal D Threaded Wall
Take-Out mm mm mm mm mm kg LPCB FM UL MEA NSF
DN In. DN In. Size
1
80459 25 1” 15 ⁄ 2” NPT 92mm (3-5 ⁄ 8") 40 92 47 34 17 0.218 5
⁄ 8” √ √ √ √ √
1
80460 25 1” 15 ⁄ 2” NPT 86mm (3-3 ⁄ 8") 40 85 47 30 17 0.209 1
⁄ 2” √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-23
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC Fittings

Back-to-Back Sprinkler Head Cross, Slip x Female Thread


Sizes DN25 x DN15 (1" x 1/2")

Approvals UL, C-UL Listed & FM,MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

T/O 1 T/O 1

2
T/O
D

B
A

CPVC Back-to-Back Sprinkler Head Cross, Slip x Female Thread


Size Dry Approval Listings
A G H T/O1 T/O2 Weight
Part No. B Nominal D Threaded Wall
Take-Out mm mm mm mm mm kg LPCB FM UL MEA NSF
DN In. DN In. Size
1
80462 25 1” 15 ⁄ 2” NPT 86mm (3-3 ⁄ 8") 40 86 45.5 30 15 0.209 1
⁄ 2” √ √ √ √ √
1
80463 25 1” 15 ⁄ 2” NPT 92mm (3-5 ⁄ 8") 40 93 45.5 34 15 0.213 5
⁄ 8” √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-24
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings
CPVC Fittings

Raven Studio Sprinkler Adapter 90° Elbow


Sizes DN25 (1" )

Approvals UL, C-UL Listed & FM,MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

T/O Y

Y
T/O X

CPVC Raven Studio Sprinkler Adapter 90° Elbow


Size Nominal Take-Out Approval Listings
Pipe Weight
Part No. X Nominal
Y Threaded X Y Schd. kg LPCB FM UL MEA NSF
DN In.
ISO 228 19mm 44,5mm
82198 25 1” 40 0.12 √ √ √ √ √
G3/8 (3 ⁄4") (1-3 ⁄4")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-25
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC Fittings

Raven Studio Sprinkler Adapter Tee


Sizes DN25 (1" )

Approvals UL, C-UL Listed & FM,MEA, NSF, & LPCB Approved

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1915 and
Tech Data Sheet
Installation Handbook - IH-1900

Manufactured with Lubrizol's BLAZEMASTER® compound • Produced from BlazeMaster® thermoplastic compound, RAPID
RESPONSE CPVC fittings are designed exclusively for use in wet and dry pipe automatic fire sprinkler systems. • Our CPVC is easier
to install than traditional steel components, while providing superior heat resistance and strength compared to traditional CPVC
and PVC fitting materials.

X Y

T/O Z

T/O X T/O Y

CPVC Raven Studio Sprinkler Adapter Tee


Size Nominal Take-Out Approval Listings
Pipe Weight
Part No. X & Y Nominal
Z Threaded X Y Z Schd. kg LPCB FM UL MEA NSF
DN In.
ISO 228 17,4mm 17,4mm 41,3mm
82251 25 1” 40 0.13 √ √ √ √ √
G3/8 (0.687") (0.687") (1.625")

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-26
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings

CPVC
Rapid Seal Adapter (RSA), Adapter Slip x Female Thread
DN20 x DN15 & DN25 x DN15
Sizes
(3 ⁄4" x 1 ⁄ 2" & 1" x 1 ⁄ 2")

Pipe Thread 1
/2" NPS
Connection

UL, C-UL Listed & FM Approved, LPCB Certified


Approvals
NSF-pw Certified

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1925 and
Tech Data Sheet
Installation Handbook - IH-1900

Rapid Seal Adapter (RSA) Fittings are intended for use in fire protection sprinkler systems comprised of CPVC pipe and fittings.
A gasket housed within the fitting eliminates the need to apply sealant to sprinkler threads and reduces the effort necessary to
complete a leak-free installation. • No need for thread tape or sealant • No brass, no lead, no dezincification • Thanks to its brass-
free design, Rapid Seal is not prone to dezincification in hard water environments and also complies with growing state and federal
low-lead requirements for sprinkler and plumbing systems. • 90° Elbow, Straight Adapter, Spigot, Tee, Back to Back Tee, Cross

T/O

CPVC Rapid Seal Adaptor, Slip x Female Thread


Size Approval Listings
T/O Weight
Part No. X Nominal Y Threaded
mm kg NSF-pw LPCB FM UL VdS
DN In. DN In.
3 1
80175RS2 * 20 ⁄4 ” 15 ⁄ 2” NPS 16.8 0.041 √ √ √ √ √
1
80176RS2 25 1” 15 ⁄ 2” NPS 19,8 0.049 √ √ √ √ √
* Part Number 80175RS is used for both the Rapid Seal Adapter and the Rapid Seal Adapter Spigot as it is a dual purpose fitting and
can be used in two different applications.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-27
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC

Rapid Seal Adapter (RSA), Adapter Spigot x Female Thread


Sizes DN25 x DN15 (1" x 1/2")

Pipe Thread 1
/2" NPS
Connection

UL, C-UL Listed & FM Approved, LPCB Certified


Approvals
NSF-pw Certified

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1925 and
Tech Data Sheet
Installation Handbook - IH-1900

Rapid Seal Adapter (RSA) Fittings are intended for use in fire protection sprinkler systems comprised of CPVC pipe and fittings.
A gasket housed within the fitting eliminates the need to apply sealant to sprinkler threads and reduces the effort necessary to
complete a leak-free installation. • No need for thread tape or sealant • No brass, no lead, no dezincification • Thanks to its brass-
free design, Rapid Seal is not prone to dezincification in hard water environments and also complies with growing state and federal
low-lead requirements for sprinkler and plumbing systems. • 90° Elbow, Straight Adapter, Spigot, Tee, Back to Back Tee, Cross

T/O

CPVC Rapid Seal Adaptor, Spigot x Female Thread


Size Approval Listings
T/O Weight
Part No. X Nominal Y Threaded
mm kg NSF-pw LPCB FM UL VdS
DN In. DN In.
3 1
80177RS2 20 ⁄4 ” 15 ⁄ 2” NPS 9,1 0.028 √ √ √ √ √
1
80175RS2 * 25 1” 15 ⁄ 2” NPS 13,0 0.041 √ √ √ √ √
* Part Number 80175RS is used for both the Rapid Seal Adapter and the Rapid Seal Adapter Spigot as it is a dual purpose fitting and
can be used in two different applications.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-28
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings
CPVC

Rapid Seal Adapter (RSA) 90° Elbow, Slip x Female Thread


DN20 x DN15 & DN25 x DN15
Sizes
(3 ⁄4" x 1 ⁄ 2" & 1" x 1 ⁄ 2")

Pipe Thread 1
/2" NPS
Connection

UL, C-UL Listed & FM Approved, LPCB Certified


Approvals
NSF-pw Certified

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1925 and
Tech Data Sheet
Installation Handbook - IH-1900

Rapid Seal Adapter (RSA) Fittings are intended for use in fire protection sprinkler systems comprised of CPVC pipe and fittings.
A gasket housed within the fitting eliminates the need to apply sealant to sprinkler threads and reduces the effort necessary to
complete a leak-free installation. • No need for thread tape or sealant • No brass, no lead, no dezincification • Thanks to its brass-
free design, Rapid Seal is not prone to dezincification in hard water environments and also complies with growing state and federal
low-lead requirements for sprinkler and plumbing systems. • 90° Elbow, Straight Adapter, Spigot, Tee, Back to Back Tee, Cross

T/O Y

Y
T/O X

CPVC Rapid Seal Adaptor, 90° Elbow, Slip x Female Thread


Size Approval Listings
T/O X T/O Y Weight
Part No. X Nominal Y Threaded
mm mm kg NSF-pw LPCB FM UL VdS
DN In. DN In.
3 1
80199RS2 20 ⁄4 ” 15 ⁄ 2”NPT 14,8 23,4 0.045 √ √ √ √ √
1
80198RS2 25 1” 15 ⁄ 2”NPT 28,7 25,7 0.067 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-29
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC

Rapid Seal Adapter (RSA), Adapter Tee, Slip x Female Thread


DN20 x DN15 & DN25 x DN15
Sizes
(3 ⁄4" x 1 ⁄ 2" & 1" x 1 ⁄ 2")

Pipe Thread 1
/2" NPS
Connection

UL, C-UL Listed & FM Approved, LPCB Certified


Approvals
NSF-pw Certified

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1925 and
Tech Data Sheet
Installation Handbook - IH-1900

Rapid Seal Adapter (RSA) Fittings are intended for use in fire protection sprinkler systems comprised of CPVC pipe and fittings.
A gasket housed within the fitting eliminates the need to apply sealant to sprinkler threads and reduces the effort necessary to
complete a leak-free installation. • No need for thread tape or sealant • No brass, no lead, no dezincification • Thanks to its brass-
free design, Rapid Seal is not prone to dezincification in hard water environments and also complies with growing state and federal
low-lead requirements for sprinkler and plumbing systems. • 90° Elbow, Straight Adapter, Spigot, Tee, Back to Back Tee, Cross

Y
X

T/O Z

Z
T/O X
T/O Y

CPVC Rapid Seal Adaptor Tee, Slip x Female Thread


Size Approval Listings
T/O X & Y T/O Z Weight
Part No. X & Y Nominal Z Threaded
mm mm kg NSF-pw LPCB FM UL VdS
DN In. DN In.
3 1
80250RS2 20 ⁄4 ” 15 ⁄ 2”NPT 9,7 23,4 0.049 √ √ √ √ √
1
80251RS2 25 1” 15 ⁄ 2”NPT 27,9 25,7 0.093 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-30
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings
CPVC

Rapid Seal Adapter (RSA), Adapter Back to Back Tee, Slip x Female Thread
Sizes DN25 x DN15 (1" x 1/2")

Pipe Thread 1
/2" NPS
Connection

UL, C-UL Listed & FM Approved, LPCB Certified


Approvals
NSF-pw Certified

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1925 and
Tech Data Sheet
Installation Handbook - IH-1900

Rapid Seal Adapter (RSA) Fittings are intended for use in fire protection sprinkler systems comprised of CPVC pipe and fittings.
A gasket housed within the fitting eliminates the need to apply sealant to sprinkler threads and reduces the effort necessary to
complete a leak-free installation. • No need for thread tape or sealant • No brass, no lead, no dezincification • Thanks to its brass-
free design, Rapid Seal is not prone to dezincification in hard water environments and also complies with growing state and federal
low-lead requirements for sprinkler and plumbing systems. • 90° Elbow, Straight Adapter, Spigot, Tee, Back to Back Tee, Cross

Z
Y
T/O X

X
T/O Y T/O Z

CPVC Rapid Seal Adaptor, Back to Back Tee, Slip x Female Thread
Size Approval Listings
L T/O X T/O Y & Z Weight
Part No. X Nominal Y & Z Threaded
mm mm mm kg NSF-pw LPCB FM UL VdS
DN In. DN In.
1
80460RS2 25 1” 15 ⁄ 2”NPT 85,7 9,7 34,7 0,086 √ √ √ √ √
1
80459RS2 25 1” 15 ⁄ 2”NPT 92,1 9,7 37,9 0,091 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-31
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC
Rapid Seal Adapter (RSA), Cross, Slip x Female Thread

Sizes DN25 x DN15 (1" x 1/2")

Pipe Thread 1
/2" NPS
Connection

UL, C-UL Listed & FM Approved, LPCB Certified


Approvals
NSF-pw Certified

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1925 and
Tech Data Sheet
Installation Handbook - IH-1900

Rapid Seal Adapter (RSA) Fittings are intended for use in fire protection sprinkler systems comprised of CPVC pipe and fittings.
A gasket housed within the fitting eliminates the need to apply sealant to sprinkler threads and reduces the effort necessary to
complete a leak-free installation. • No need for thread tape or sealant • No brass, no lead, no dezincification • Thanks to its brass-
free design, Rapid Seal is not prone to dezincification in hard water environments and also complies with growing state and federal
low-lead requirements for sprinkler and plumbing systems. • 90° Elbow, Straight Adapter, Spigot, Tee, Back to Back Tee, Cross

L
X

T/O X W

Z T/O Y

Y
T/O Z T/O W
CPVC Rapid Seal Adaptor, Cross, Slip x Female Thread
Size Approval Listings
L T/O X T/O Y & Z Weight
Part No. X Nominal Y & Z Threaded
mm mm mm kg NSF-pw LPCB FM UL VdS
DN In. DN In.
1
80462RS2 25 1” 15 ⁄ 2”NPT 85,7 9,7 34,7 0,094 √ √ √ √ √
1
80463RS2 25 1” 15 ⁄ 2”NPT 92,1 9,7 37,9 0,098 √ √ √ √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-32
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings
CPVC
Rapid Seal Adapter (RSA) Accessories

Rated Pressure 12,1 bar (175 psi)

Maximum
65°C (150°F).
Temperature Rating

TFP1925 and
Tech Data Sheet
Installation Handbook - IH-1900

Rapid Seal Adapter (RSA) Fittings are intended for use in fire protection sprinkler systems comprised of CPVC pipe and fittings.
A gasket housed within the fitting eliminates the need to apply sealant to sprinkler threads and reduces the effort necessary to
complete a leak-free installation.

Gasket Replacement Tool

GASKET RSA FITTING


LOAD RECESS
SURFACE
Gasket Removal Pick

GASKET
BOSS

Gaskets
GASKET
INSERTION
SHAFT
(RETRACTED)

SHAFT-END
ACCOMMODATES
3/4" SOCKET OR
LENGTH OF ROD

CPVC Rapid Seal Adaptor Accessories


Weight
Part No. Description
kg
3060 Rapid Seal Gasket Replacement Tool -
3061 Rapid Seal Gasket Removal Pick -
3062 Rapid Seal Replacement Gasket (Qty 10) -

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-33
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC Riser
Residential

Size Range DN25 thru DN50 (1" thru 2")

System For use in residential sprinkler systems

End Connection CPVC

Tech Data Sheet Contact Tyco for details

CPVC RESIDENTIAL RISER


Weight Approval & Listings
Part No DN Drain
kg UL
3
RR025CPVC 25 1” BSP ⁄4 ” 2.0 √
RR032CPVC 32 1-1 ⁄4” BSP 1” 2.1 √
RR040CPVC 40 1-1 ⁄ 2” BSP 1” 2.4 √
RR050CPVC 50 2” BSP 1” 2.5 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-34
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings
CPVC
CPVC Flow Switches - VSR-SFG
Run Sizes DN25, DN32, DN40, DN50

Pipe Connection DN25 (1")

Approvals UL

Max Pressure 12,1 bar (175 psi)

Min. Flow 38 L/Min.

IP Rating IP 56

Maximum
4° - 49°C (39° - 120°F).
Temperature Rating

Contacts 2 x SPDT [C] / 15 A - 125/250 VAC / 2 A - 30 VDC

Tech Data Sheet Installation Handbook - IH-1900

CPVC Flow Switches


Retard Setting Weight Approval Listings
Part No.
A B C D E kg UL
21000480 10-25 20-40 35-55 50-70 60-90 1.3 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-35
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC
CPVC Cement

TFP-600 One Step Solvent Cement (TFP1994)


Tech Data Sheet
and CPVC Installation Handbook (IH-1900)

One-Step CPVC Cement specifically formulated for use with BlazeMaster® pipe and fittings • BLAZEMASTER Caulk and
Walk® Firestop

CPVC Cement
Part No. Description
90766INT TFP600 CPVC CEMENT INTL PT
90767INT TFP600 CPVC CEMENT INTL QT

CPVC Dauber

Tech Data Sheet CPVC Installation Handbook (IH-1900)

CPVC Dauber
Weight
Part No. Description
kg
90400 Dauber 1-1 ⁄ 2” Diameter for Pipe Sizes 1” to 3” 0.011
90401 Dauber 3 ⁄4” Diameter for Pipe Sizes 3 ⁄4” to 1-1 ⁄4” 0.008

CPVC Pipe Cutter Tool - TC2QPVC

Tech Data Sheet CPVC Installation Handbook (IH-1900)

CPVC Pipe Cutter Tool - TC2QPVC


Weight
Part No. Description
kg
90355 Pipe Cutter Model TC2QPVC with wheel for CPVC Pipe, Diameters DN20 to DN80 1.1
90356 Replacement Cutter Wheel Model 3-6PVC for Model TC3qPVC Pipe Cutter 0.01

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-36
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings
CPVC
CPVC Deburring Tools, DEB2 & DEB4

Tech Data Sheet CPVC Installation Handbook (IH-1900)

DEB2

DEB4

CPVC Deburring Tools, DEB2 & DEB4


Weight
Part No. Description
kg
91346 Deburring Tool for Inner and Outer edges of Pipes, for Pipe Sizes up to DN50 1.1
90357 Deburring Tool for Inner and Outer edges of Pipes, for Pipe Sizes DN32 up to DN80 0.01

CPVC Test Plugs

Tech Data Sheet CPVC Installation Handbook (IH-1900)

CPVC Test Plugs


Size Weight
Part No. Description Colour
DN in kg
1
902700 15 ⁄ 2" Test Plug, Brass thread 1 ⁄ 2” for Sprinkler Fittings white 0.115
3
902701 20 ⁄4 " Test Plug, Brass thread 3 ⁄4” for Sprinkler Fittings white 0.125

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-37
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

CPVC Pipe & Threaded Fittings


CPVC
CPVC Thread Sealant

Tech Data Sheet CPVC Installation Handbook (IH-1900)

CPVC Thread Sealant


Weight
Part No. Package Size Description
kg
90505 5 ltr. 5 Litre Can Antifreeze for CPVC Systems, USP Grade [96.5%] 0.4

CPVC Caulk & Walk®

Tech Data Sheet CPVC Installation Handbook (IH-1900)

CPVC Caulk & Walk®


Weight Approval Listings
Part No. Size Description
kg UL
61126 0.3 ltr, Tube Caulk & Walk Fire Stopping Sealant 0.4 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

6-38
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
CPVC Pipe & Threaded Fittings
CPVC

CPVC Model SHB1 Head Set Hangers


3
Sizes ⁄4" thru 1" NPT

Approvals UL Listed

Material Galvanized aluminium, 20 gauge

TFP1920 and
Tech Data Sheet
Installation Handbook - IH-1900

“No Block Hanger" is a two hole strap that eliminates blocking to the beam when hanging CPVC pipe • The TYCO CPVC Hanger
Head Set Model SHB1 offers a time saving installation method for proper placement of an automatic sprinkler before the ceiling
is installed. • Positions the face of the pipe 1-1 ⁄ 2" off the face of the joist • Provides vertical restraint, eliminating need for
additional hangers

CPVC Model SHB1 Head Set Hanger


Weight Approval Listings
Part No. Works with Sprinkler Head Adapters Description
kg UL
HS2 80175W, 80176W Model SHB1 Head Set Hanger 0.12 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 6-39
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
MLC-S Sprinkler Pipe and Fittings for Concrete Ceilings
Multi-Layer Composite Pipe System Sprinkler

- For use in Wet Systems on - Inseparable, Permanently Tight


Supply and Distribution Lines Press Joint
That Are Fully Embedded in
Concrete - VdS-Approved Pipe System for
the Installation of Pipe Conduits
- Easy, Quick, and Clean Process in Sprinkler Ceilings per VdS
-- no Welding, Soldering,
Thread-cutting or Gluing

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 7-1
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

MLC-S Sprinkler Pipe & Fittings for Concrete Ceilings


MLC-S Pipe

MLC-S Sprinkler Pipe


Sizes 32 x 3 and 50 x 4.5 (DN25 & DN40)

Pipe Length 50m Coils or 5m Straight lengths

Approvals VdS approval no. G 4060066.

Maximum Operating
10 bar (145 psi)
Pressure

Maximum
-10° - 40°C (14° - 104°F)
Temperature Rating

Colour Bright red in colour as conforming to RAL 3000

Tech Data Sheet Contact Tyco for details

100% oxygen diffusion tight multi-layer composite pipe (PE-RT – adhesive – overlapping longitudinally welded aluminium –
adhesive – PE-RT) for the installation of pipelines (cold drinking water) as part of the sprinkler ceiling installation according to VdS
approval no. G 4060066.

Structure of the Tyco Longitudinally welded


aluminium pipe
MLCP-S sprinkler pipe
Adhesive Adhesive
PE-RT PE-RT

MLC-S Sprinkler Pipe


Di Approval &
Dimension Nominal Unit Weight Weight
Part No. Inside Listings
da x s [mm] Size Length per coil or rod per Meter
Diameter VdS
735320 32 x 3 red in Coils DN25 26mm 50 m 16.2 0.323 √
1045982 50 x 4.5 red in Lengths DN40 41mm 5m 3.72 0.745 √

MLC-S Sprinkler System

MLC-S Pipe MLC-S


Fittings

Connection to Fire Sprinkler Connection Fittings


Fighting Water Supply

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

7-2
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
MLC-S Sprinkler Pipe & Fittings for Concrete Ceilings
MLC-S Press Fittings
Male Press Connection

Sizes 32 x 1"MT and 50 x 1-1/2" MT

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

Tin-plated brass, with fixed press sleeve and pressing jaw stop. • For the connection of the sprinkler ceiling to the extinguishing
water supply system according to VdS approval no. G 4060066. • Male thread according to DIN EN 10226-1 for sealing.

L
Z MLC-S Male Press Connection
Approval &
Z L Weight
Part No. Dimension Listings
mm mm kg
VdS
980301 32 x 1 MT 34 65 0.184 √
1045988 50 x 1 1/2 MT 42 79 0.511 √

Female Press Connection

Sizes 32 x 1 FT and 50 x 1-1 ⁄ 2 FT

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

Tin-plated brass, with fixed press sleeve and pressing jaw stop. • For the connection of the sprinkler ceiling to the extinguishing
water supply system according to VdS approval no. G 4060066. • Cylindrical female thread according to DIN EN 10226-1.

L
L1 Z

MLC-S Female Press Connection


Approval &
Z L L1 Weight
Part No. Dimension Listings
mm mm mm kg
VdS
980302 32 x 1 FT 11 61 31 0.208 √
1045986 50 x 1-1 ⁄ 2 FT 14 73 37 0.397 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 7-3
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

MLC-S Sprinkler Pipe & Fittings for Concrete Ceilings


MLC-S Press Fittings
Press Elbow 90°

Sizes 32 x 32 and 50 x 50

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

Tin-plated brass, with fixed press sleeves and pressing jaw stops. • For use in the installation of pipes in sprinkler ceilings
according to VdS approval no. G 4060066.

L
Z MLC-S Press 90° Elbow
Approval &
Z L Weight
Part No. Dimension Listings
mm mm kg
VdS
980303 32 x 32 23 53 0.239 √
1045984 50 x 50 41 78 0.687 √

Press Male 90° Elbow

Sizes 32 x 1 MT

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

Tin-plated brass, with fixed press sleeve and pressing jaw stop. • For the connection of the sprinkler ceiling to the extinguishing
water supply system according to VdS approval no. G 4060066. • Male thread according to DIN EN 10226-1 for sealing.

L1

Z1

Z
L

MLC-S Press Male 90° Elbow


Approval &
Z Z1 L L1 Weight
Part No. Dimension Listings
mm mm mm mm kg
VdS
980304 32 x 1 MT 26 28 44 58 0.259 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

7-4
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
MLC-S Sprinkler Pipe & Fittings for Concrete Ceilings
MLC-S Press Fittings
Press Female 90° Elbow

Sizes 32 x 1 FT and 50 x 1-1 ⁄ 2 FT

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

Tin-plated brass, with fixed press sleeve and pressing jaw stop. • For the connection of the sprinkler ceiling to the extinguishing
water supply system according to VdS approval no. G 4060066. • Cylindrical female thread according to DIN EN 10226-1.

Z1

L1

Z
L
MLC-S Press Female 90° Elbow
Approval &
Z Z1 L L1 Weight
Part No. Dimension Listings
mm mm mm mm kg
VdS
980305 32 x 1 FT 29 28 47 58 0.293 √
1059489 50 x 1-1 ⁄ 2 FT 38 41 59 81 0.629 √

Press 45° Elbow

Sizes 50 x 50

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

Tin-plated brass, with fixed press sleeves and pressing jaw stops. • For use in the installation of pipes in sprinkler ceilings
according to VdS approval no. G 4060066.

MLC-S Press 45° Elbow


Approval &
Z L Weight
Part No. Dimension Listings
mm mm kg
Z VdS
1045990 50 x 50 25 63 0.556 √
L

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 7-5
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

MLC-S Sprinkler Pipe & Fittings for Concrete Ceilings


MLC-S Press Fittings
Press Tee

Sizes 32 x 32 x 32 and 50 x 50 x 50

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

Tin-plated brass, with fixed press sleeves and pressing jaw stops. • For use in the installation of pipes in sprinkler ceilings
according to VdS approval no. G 4060066.

L
Z
MLC-S Press Tee
Approval &
Z L Weight
Part No. Dimension Listings
mm mm kg
VdS
980307 32 x 32 x 32 23 53 0.330 √
1045992 50 x 50 x 50 41 78 0.962 √

Press Tee Reducer

Sizes 50 x 32 x 50

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

Tin-plated brass, with fixed press sleeves and pressing jaw stops. • For use in the installation of pipes in sprinkler ceilings
according to VdS approval no. G 4060066.

L2

Z2

Z1
L1

Z
L

MLC-S Press Tee Reducer


Approval &
Z Z1 Z2 L L1 L2 Weight
Part No. Dimension Listings
mm mm mm mm mm mm kg
VdS
1045994 50 x 32 x 50 35 27 27 65 64 64 0.685 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

7-6
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
MLC-S Sprinkler Pipe & Fittings for Concrete Ceilings
MLC-S Press Fittings

Press Coupling

Sizes 32 x 32 and 50 x 50

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

Tin-plated brass, with fixed press sleeves and pressing jaw stops. • For use in the installation of pipes in sprinkler ceilings
according to VdS approval no. G 4060066.

L
Z MLC-S Press Coupling
Approval &
Z L Weight
Part No. Dimension Listings
mm mm kg
VdS
980308 32 x 32 12 73 0.161 √
1045996 50 x 50 13 88 0.358 √

Press Reducer

Sizes 50 x 32

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

Tin-plated brass, with fixed press sleeves and pressing jaw stops. • For use in the installation of pipes in sprinkler ceilings
according to VdS approval no. G 4060066.

L Z L1

MLC-S Press Reducer


Approval &
Z L L1 Weight
Part No. Dimension Listings
mm mm mm kg
VdS
1045998 50 x 32 13 38 30 0.278 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 7-7
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

MLC-S Sprinkler Pipe & Fittings for Concrete Ceilings


MLC-S Press Fittings
Male/Female Press 90° Elbow
32 x 1" MT & 1 ⁄ 2 FT or
Sizes
32 x 1" MT & 3 ⁄4 FT

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

Tin-plated brass, with fixed press sleeve and red pressing jaw stop. • 1 MT male thread for the connection of Tyco sprinkler
boxes to the Tyco MLCP-S sprinkler pipes in sprinkler ceilings according to VdS approval no. G 4060066. • Cylindrical female
thread according to DIN EN 10226-1.

L
Z

L1
Z2 Z1

MLC-S Male/Female Press 90° Elbow


Approval &
Z Z1 Z2 L L1 Weight
Part No. Dimension Listings
mm mm mm mm mm kg
VdS
986246 32 x 1 MT / 1 ⁄ 2 FT 25 29 35 56 45 0.340 √
986346 32 x 1 MT / 3 ⁄4 FT 25 29 35 56 45 0.275 √

Female Press Elbow 90°


32 x 3 ⁄4 FT and
Sizes
50 x 3 ⁄4 FT

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

Tin-plated brass, with fixed press sleeve and red pressing jaw stop. • 3 ⁄4 FT female thread for the connection of Tyco sprinkler
boxes to the Tyco MLCP-S sprinkler pipes in sprinkler ceilings according to VdS approval no. G 4060066. • Cylindrical female
thread according to DIN EN 10226-1.

MLC-S Female Press Elbow 90°


Approval &
L1 Z Z1 L L1 Weight
Part No. Dimension Listings
mm mm mm mm kg
Z1 VdS
1059146 32 x 3 ⁄4 FT 31 25 47 56 0.339 √
1059148 50 x 3 ⁄4 FT 31 41 47 78 0.685 √

Z
L

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

7-8
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
MLC-S Sprinkler Pipe & Fittings for Concrete Ceilings
MLC-S Press Fittings
Female Press Sprinkler Tee

Sizes 50 x 3 ⁄4 FT x 50

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

Tin-plated brass, with fixed press sleeve and red pressing jaw stop. • 3 ⁄4 FT female thread for the connection of Tyco sprinkler
boxes to the Tyco MLCP-S sprinkler pipes in sprinkler ceilings according to VdS approval no. G 4060066. • Cylindrical female
thread according to DIN EN 10226-1.

L
Z
MLC-S Female Press Sprinkler Tee
L1 Approval &
Z Z1 L L1 Weight
Part No. Dimension Listings
Z1 mm mm mm mm kg
VdS
1059145 50 x 3 ⁄4 FT x 50 31 34 - 47 0.710 √

Male/Female Press Sprinkler Tee


32 x 1 MT / 1 ⁄ 2 FT x 32 and
Sizes
32 x 1 MT / 3 ⁄4 FT x 32

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

Tin-plated brass, with fixed press sleeve and red pressing jaw stop. • 1 MT male thread for the connection of Tyco sprinkler
boxes to the Tyco MLCP-S sprinkler pipes in sprinkler ceilings according to VdS approval no. G 4060066. • Cylindrical female
thread according to DIN EN 10226-1.

L1
Z2
Z1

MLC-S Male/Female Press Sprinkler Tee


Approval &
Z Z1 Z2 L L1 Weight
Part No. Dimension Listings
mm mm mm mm mm kg
VdS
Z 986236 32 x 1 MT / 1 ⁄ 2 FT x 32 26 29 35 56 45 0.370 √
986336 32 x 1 MT / 3 ⁄4 FT x 32 26 29 35 56 45 0.354 √
L

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 7-9
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

MLC-S Sprinkler Pipe & Fittings for Concrete Ceilings


MLC-S Press Fittings
Press Connection
32 x 1 MT / 1 ⁄ 2 FT and
Sizes
32 x 1 MT / 3 ⁄4 FT

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

Tin-plated brass, with fixed press sleeve and red pressing jaw stop. • 1 MT male thread for the connection of Tyco sprinkler
boxes to the Tyco MLCP-S sprinkler pipes in sprinkler ceilings according to VdS approval no. G 4060066. • Cylindrical female
thread according to DIN EN 10226-1.

MLC-S Press Connection


Approval &
Z1 Z2 L Weight
Part No. Dimension Listings
mm mm mm kg
VdS
986226 32 x 1 MT / 1 ⁄ 2 FT 17 12 65 0.200 √
986326 32 x 1 MT / 3 ⁄4 FT 17 12 59 0.164 √

Repair Coupling

Sizes 32 x 32

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

Tin-plated brass, with fixed press sleeve. • Repair and compensating press fitting with extended inner insert. • Adjusting
range 48 mm.

L
Z1 Z2 Concrete element Concrete element

MLC-S Repair Coupling


Approval &
Z1 Z2 L Weight
Part No. Dimension Listings
mm mm mm kg Repair coupling
VdS
946163 32 x 32 43 48 125 0.360 √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

7-10
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
MLC-S Sprinkler Pipe & Fittings for Concrete Ceilings
MLC-S Tools
Pipe Cuttings Tool 25-63

Sizes 25 - 63mm

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

For Tyco pipes, outside diameter 25 – 63 mm.

MLC-S Pipe Cutting Tool 25-63


Approval &
Part No. Dimension Unit Listings
VdS
760005 25-63 mm 1 pc. √
760011 Spare Cutting Wheel 1 pc. √

Bevelling Tool

Sizes 32 and 50

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

For the deburring of Tyco MLC / Tyco Velta PE-Xa pipes. Complete with handle. • Suitable for attachment to power drill with
max. 500 rpm (remove handle).

MLC-S Bevelling Tool


Approval &
Part No. Size Unit Listings
VdS
996400 32 1 pc. √
1015808 50 1 pc. √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 7-11
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

MLC-S Sprinkler Pipe & Fittings for Concrete Ceilings


MLC-S Tools
Internal Bending Spring

Sizes 32mm

Tech Data Sheet Contact Tyco for details

For Tyco MLC pipes, diameter 14 - 32 mm.

MLC-S Internal Bending Spring


Part No. Type Unit
760032 32 1 pc.

Bending Tool

Sizes 16, 20, 25, 32mm

Tech Data Sheet Contact Tyco for details

For the production of uniform bends in Tyco MLC pipes. Complete with case and bending inserts.

MLC-S Bending Tool


Part No. Size Unit
760532 16, 20, 25, 32 1 pc.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

7-12
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
MLC-S Sprinkler Pipe & Fittings for Concrete Ceilings
MLC-S Tools
Battery Pressing Tool UP 75
Sizes 14 - 110 mm

Approvals VdS approval no. G 4060066.

Pressing Force min. 32 kN

Pressing Time approx. 7 sec.

Tech Data Sheet Contact Tyco for details

In plastic case, including battery pack and charger. • Pressing jaws not included. • For dimensions 14 – 110 mm.

MLC-S Battery Pressing Tool UP 75


Approval
Part No. Type Unit & Listings
VdS
UP 75 suitable for 14mm to 110mm pipe
990005 1 pc. √
supplied without pressing jaw

Spare rechargeable battery


990010 1 pc.
12V / 3 Ah NiMH, for Tyco UP 75 battery pressing tool.

Spare charger unit For Tyco battery of UP 75 and


990020 1 pc.
Mini 32 KSP0 pressing tool.

Electric Pressing Tool UP 75 EL


Sizes 14 - 110 mm

Approvals VdS approval no. G 4060066.

Pressing Force min. 32 kN

Pressing Time approx. 7 sec.

Tech Data Sheet Contact Tyco for details

With plastic case. Pressing jaws not included. • For dimensions 14 – 110 mm.

MLC-S Electric Pressing Tool UP 75 EL


Approval &
Part No. Type Unit Listings
VdS
uP 75 eL suitable for 14mm to 110mm pipe
1007082 1 pc. √
supplied without pressing jaw

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 7-13
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

MLC-S Sprinkler Pipe & Fittings for Concrete Ceilings


MLC-S Tools
Pressing Jaw MLC

Sizes 32 and 50

Approvals VdS approval no. G 4060066.

Tech Data Sheet Contact Tyco for details

Tyco MLC KSP0 pressing jaws for Tyco MLC press fittings

MLC-S Pressing Jaw MLC


Approval &
Part No. Dimension Type Unit Listings
VdS
1007088 32 MLC KSPO 1 pc. √
1015792 50 MLC (UPP1) 1 pc. √

Battery Pressing Tool Mini 32

Sizes 14 to 32mm

Pressing Force min. 15 kN (linear)

Pressing Time approx. 4 sec.

Tech Data Sheet Contact Tyco for details

In plastic case, including battery, charger and pressing jaws for dimensions 16 / 20 / 25 / 32. • Suitable for dimensions 14 – 32mm.

MLC-S Battery Pressing Tool Mini 32


Part No. Type Unit
Mini 32 suitable for 14mm to 32mm pipe
1083586 1 pc.
supplied with pressing jaw
990066 Replacement battery Mini 1 pc.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

7-14
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
MLC-S Sprinkler Pipe & Fittings for Concrete Ceilings
MLC-S Tools
Pressing Jaw MLC Mini KSPO

Sizes 32mm

Tech Data Sheet Contact Tyco for details

Tyco MLC Mini KSP0 pressing jaws for Tyco MLC press fittings 32 mm.

MLC-S Pressing Jaw MLC Mini KSPO


Part No. Type Unit
1007095 32 1 pc.

Universal Casting Cup for Sprinklers in Concrete Floors

Universal Casting Cup

Sizes 1" ISO

Tech Data Sheet Contact Tyco for details

This Stainless Steel Cup is used in conjuction with the LFII recessed or flush pendent sprinkler. Fixing this cup can be done with
the Metal Plate shown below. This is a non-re-useable cup. • The Stainless Steel Metal Plate is mounted between the Metal Cup
and the Sprinkler fitting. This assembly can be fixed to the timber with nails.

MLC-S Universal Casting Cup


Part No. Dimension Description
To be used with Tyco Flush
METALCAP6 1” ISO Pendent Sprinklers 1 ⁄ 2”
& 3 ⁄4 NPT

To be used with Tyco


METALCAP7 1” ISO Recessed Pendent Sprinklers
1
⁄ 2” & 3 ⁄4 NPT

for 1" Metal Plate is used to fix


PD0222
Fittings the Stainless Steel Cups

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 7-15
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

MLC-S Sprinkler Pipe & Fittings for Concrete Ceilings


Universal Casting Cup for Sprinklers in Concrete Floors

Installation Cup, Plug, & Cap

Sizes 1" ISO

Tech Data Sheet Contact Tyco for details

The Installation Cup is used in conjunction with the FSC (Flush Sprinkler for Concrete). • The corresponding plug is used
for fixing (with nails) the position of the cup. For more information on the usage of the Installation Cup see TFP645. • The
Installation Cup is re-useable. The plug is also available separately (PN 913131004).

MLC-S Installation Cup, Plug and Cap


Part No. Dimension H Ø Type Qty
3
913131110 ⁄4” ISO, Ø 70mm, h = 56mm 65 70 32 1
An End Cap can be used to avoid
1013423-1 29 32 - 1
concrete splashes
The Plastic Plug for Metalcap
PLASTLOKKM7 6 and 7. Must be used in 29 32 - 1
combination with Plattendekke

Removal Tool

Sizes 27mm Wrench

Tech Data Sheet Contact Tyco for details

The Removal Wrench is used for removing the Installation Cup. The tool can be used in combination with a 1 ⁄ 2“ Socket Drive or a
27mm Wrench.

MLC-S Removal Tool


Part No. Dimension H Ø Qty
560004301 27mm (1 ⁄ 2”) Socket 44 55 1

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

7-16
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Flexible Hose, Welding Outlets and Threaded Fittings

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 8–1
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Flexible Hose
FASTFLEX
Flexible Sprinkler Hose Assembly

Sizes 700 - 1800 mm lengths

Approvals UL Listed & FM & VdS & LPCB Approved

Max. Pressure UL: 12.1 bar; FM: 12 bar; LPCB/VdS: 16 bar

Tech Data Sheet TFP720

The TYCO FASTFLEX Flexible Sprinkler Hose is a unique sprinkler drop assembly comprised of a branchline adapter nipple, stainless
steel flexible hose with two slip nuts, sprinkler reducer, and lightweight ceiling bracket components.

FASTFLEX Model YN25, YB25, and YB28 - Flexible Sprinkler Hose Assembly
Approval & Listings
Hose Weight
Part Number Type Internal Ø
Length kg UL FM VdS LPCB APSAD Ukrainian CSTB
YN250700 Unbraided 700 25 1 √ – – √ √ √ √
YN251000 Unbraided 1000 25 1.1 √ – – √ √ √ √
YN251200 Unbraided 1200 25 1.16 √ – – √ √ √ √
YN251500 Unbraided 1500 25 1.23 √ – – √ √ √ √
YN251800 Unbraided 1800 25 1.3 √ – – √ √ √ √
YB280700 Braided 700 28 1.24 √ – √ – √ √ √
YB281000 Braided 1000 28 1.38 √ – √ – √ √ √
YB281200 Braided 1200 28 1.48 √ – √ – √ √ √
YB281500 Braided 1500 28 1.58 √ – √ – √ √ √
YB281800 Braided 1800 28 1.7 √ – √ – √ √ √
YB28700-F Braided 700 28 1.28 √ √ – – – √ √
YB281000-F Braided 1000 28 1.45 √ √ – – – √ √
YB281200-F Braided 1200 28 1.6 √ √ – – – √ √
YB281500-F Braided 1500 28 1.78 √ √ – – – √ √
YB281800-F Braided 1800 28 1.9 √ √ – – – √ √

Parts List
Item
Description Material Quantity 3
No.
1 Flexible Tube SS AISI 304 1
2 Weaver SS AISI 304 1 4
3 Braid Ring Mild Steel 2 3
4 Nipple Mild Steel 1 1
5* Sprinkler Reducer Mild Steel 1 1 2
6 Slip Nut Brass 1
7 O-Ring NBR/CR 2
2
8 Washer Nylon W6 2
9 Bracket Pressed Steel 1
10* Clamps Pressed Steel 2 7
6
11 Support Bar Pressed Steel 1
5 10 10 9
*Note part 5: Sprinkler Reducer is straight, 1 ⁄ 2” NPT
thread. Elbows 45° or 90° and 3 ⁄4” NPT Connections
11
available on request.
*Note part 10: Standard Clamp to be used for
Recessed Sprinklers. Special Clamp for Concealed
Sprinklers available on request.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

8–2
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Flexible Hose
FASTFLEX SPRINKLER ACCESSORIES
Sprinkler Reducers

1
Sizes ⁄ 2" NPT, 3 ⁄4" NPT and ISO 7-Rc-3/8

Tech Data Sheet TFP720

25 or 28 mm ID
Sprinkler Reducers - 1/2" NPT Outlet - Parts List (Straight, 45 Degree, or 90 Degree) Male Hose
Part Inlet Hose Threaded
Description Outlet Inlet
Number Ø [mm]
1
RBAR45 45°-Elbow Reducer Mild Steel 25 ⁄ 2” NPT Female
1
RB28AR45 45°-Elbow Reducer Mild Steel 28 ⁄ 2” NPT Female
1
RBAR90 90°-Elbow Reducer Mild Steel 25 ⁄ 2” NPT Female ISO 7-Rc 3/8,
RBAR90S 90°-Elbow Reducer Short Special Brass 25 1
⁄ 2” NPT Female 120 mm
1/2" NPT,
1
RB28AR90 90°-Elbow Reducer Mild Steel 28 ⁄ 2” NPT Female or 3/4" NPT
RBR120 Straight Reducer Mild Steel 25 1
⁄ 2” NPT Female Female Pipe
1 Threaded
RBR28120 Straight Reducer Mild Steel 28 ⁄ 2” NPT Female Outlet
STRAIGHT
25 or 28 mm ID
Male Hose
133 mm
Sprinkler Reducers - 3/4" NPT Outlet - Parts List (Straight, 45 Degree, or 90 Degree) Threaded
Part Inlet Hose Inlet
Description Outlet
Number Ø [mm]
3
SBAR45 45° - Elbow Reducer Mild Steel 25 ⁄4” NPT Female
3
SB28AR45 45° - Elbow Reducer Mild Steel 28 ⁄4” NPT Female ISO 7-Rc 3/8,
3
120 mm
SBAR90 90° - Elbow Reducer Mild Steel 25 ⁄4” NPT Female 1/2" NPT,
SBAR90S 90° - Elbow Reducer Short Special Brass 25 3
⁄4” NPT Female or 3/4" NPT
3 Female Pipe
SB28AR90 90° - Elbow Reducer Mild Steel 28 ⁄4” NPT Female Threaded
3
SBR120 Straight Reducer Mild Steel 25 ⁄4” NPT Female Outlet
3
SBR28120 Straight Reducer Mild Steel 28 ⁄4” NPT Female 90 DEGREE

37 mm 25 mm ID
Male Hose
Sprinkler Reducers - ISO 7-Rc 3/8 Outlet - Parts List (Straight, 45 Degree, or 90 Degree) Threaded
Part Inlet Hose Inlet
Description Outlet
Number Ø [mm]
PBAR45 45° - Elbow Reducer Mild Steel 25 ISO 7-Rc 3/8
PB28AR45 45° - Elbow Reducer Mild Steel 28 ISO 7-Rc 3/8 1/2" NPT
Female Pipe
PBAR90 90° - Elbow Reducer Mild Steel 25 ISO 7-Rc 3/8 Threaded
PB28AR90 90° - Elbow Reducer Mild Steel 28 ISO 7-Rc 3/8 68,5 mm Outlet
PBR120 Straight Reducer Mild Steel 25 ISO 7-Rc 3/8 90 DEGREE SHORT RADIUS
PBR28120 Straight Reducer Mild Steel 28 ISO 7-Rc 3/8 (LPCB APPROVED APPLICATIONS ONLY)

25 or 28 mm ID
Male Hose
125 mm Threaded
Inlet

125 mm ISO 7-Rc 3/8,


1/2" NPT,
or 3/4" NPT
Female Pipe
Threaded
Outlet

45 DEGREE

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 8–3
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Flexible Hose
FASTFLEX SPRINKLER ACCESSORIES
Bar Fixing Clamps

Tech Data Sheet TFP720

Bar Fixing Clamps


Part Length
Description
Number mm
RBF58T Bar Fixing Clamp for recessed sprinkler 50
RBF90T Bar Fixing Clamp for concealed sprinkler 90
RBF38T Bar Fixing Clamp Special for plasterboard ceilings 38

50 mm

90 mm

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

8–4
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Flexible Hose
Fastflex Flexible Hose Accessories
NIPPLES

25mm x 1" BSP, 25mm x 1-1 ⁄4" BSP


Sizes
28mm x 1" BSP, 28mm x 1-1 ⁄4" BSP

Tech Data Sheet Contact Tyco for details

NIPPLES - Parts List


Part Inlet Hose
Description Outlet
Number Ø [mm]
HOSENIP25 Hose Nipple 25 1” BSP Male
HOSENIP25R Reduced Hose Nipple 25 1-1 ⁄4” BSP Male
HOSENIP28 Hose Nipple 28 1” BSP Male
HOSENIP28R Reduced Hose Nipple 28 1-1 ⁄4” BSP Male

Minimum Radius Indicator

Sizes 55mm radius

Tech Data Sheet Contact Tyco for details

Minimum Radius Indicator. Only for hoses with a 25mm diameter


Part
Description
Number
MRI55 Minimum radius indicator plastic clip with radius 55 mm

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 8–5
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Drop Nipples
LONGNECK
Reduced Ends Model Longneck
DN25 x 3/8" ISO, DN25 x 1/2" NPT,
Sizes
DN25 x 3/4" NPT

Approvals FM & VdS Approved

Material Steel pipe S195T according EN 10255-M

Finish Zinc coated

Max. Pressure 20.7 bar (300psi)

Tech Data Sheet Contact Tyco for details

Special lengths are available upon request

Reduced Ends Model Longneck


O.D. Length Outlets Weight Approval & Listings
Part Number
DN mm mm Female kg FM VdS
3
1412100010 25 [1”] 34 1000 ⁄ 8” ISO 2,4 √ √
1
1412100015 25 [1”] 34 1000 ⁄ 2” NPT 2,4 √ √
3
1412100020 25 [1”] 34 1000 ⁄4” NPT 2,4 √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

8–6
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Drop Nipples
M&F
Drop Nipples

Sizes 90mm - 270mm lengths

Approvals FM & VdS Approved

Material Shaft Steel pipe ST37

Material “O” Rings EPDM

Finish CED coated (black)

Working Temperature -20°C to 100°C

Max. Pressure Max. 25 Bar [362 Psi] for Sprinkler systems

Tech Data Sheet Contact Tyco for details

Special lengths are available upon request

M&F
Inlet Size Outlet Size NPT Adjustment
Min. L Max. L Weight Approval & Listings
Part Number BSP Female Range
mm mm kg
In. mm Male/Female In. mm mm FM VdS
1
DROPMF090050 1” 25 M ⁄ 2” 15 90 140 50 0,35 √ √
1
DROPMF100060 1” 25 M ⁄ 2” 15 100 160 60 0,35 √ √
1
DROPMF140100 1” 25 M ⁄ 2” 15 140 240 100 0,5 √ √
3
DROPMF180100 1” 25 M ⁄4 ” 20 180 280 100 0,7 √ √
1
DROPMF220100 1” 25 M ⁄ 2” 15 220 320 100 0,7 √ √
1
DROPFF130060 1” 25 F ⁄ 2” 15 130 190 60 0,45 √ √
1
DROPFF170100 1” 25 F ⁄ 2” 15 170 270 100 0,6 √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 8–7
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Branch Outlets
TEE-LET THREADED
Branch Outlets Threaded

Sizes DN15 thru DN65

Approvals UL Listed & FM Approved

Material Black Steel to ASTM A106

Tech Data Sheet Contact Tyco for details

Tee-Let Threaded
Outlet Size Outlet Inside Approval &
Header for Pipe Size Weight
Part Number Female Length ØA Listings
kg
DN In DN in C mm mm UL FM
WB12X114NTHR 32-40 1-1 ⁄4" - 1-1 ⁄ 2" √ √ C
1
15 ⁄ 2" NPT 27.0 27.5 0.07
WB12X5NTHR 80-200 3"-8" √ √
WB34X114NTHR 32-40 1-1 ⁄4" - 1-1 ⁄ 2" √ √
20 3/4" NPT 28.6 33.8 0.10
WB34X5NTHR 80-200 3"-8" √ √
WB1X2THR 50 2" 0.13 √ √
ØA
WB1X212THR 65 2-1 ⁄ 2" 0.13 √ √
25 1" BSP 31.7 39.5
WB1X3THR 80-100 3"-4" 0.11 √ √
WB1X6THR 125-200 5"-8" 0.12 √ √
WB114X112THR 40 1-1 ⁄ 2" 0.18 √ √
WB114X2THR 50 2" 0.17 √ √
32 1-1 ⁄4" BSP 34.9 47.5
WB114X3THR 80-100 3"-4" 0.16 √ √
WB114X6THR 125-200 5"-8" 0.16 √ √
WB112X2THR 50 2" 0.29 √ √
WB112X212THR 65 2-1 ⁄ 2" 0.29 √ √
40 1-1 ⁄ 2" BSP 41.3 55.0
WB112X3THR 80-100 3"-4" 0.28 √ √
WB112X6THR 125-200 5"-8" 0.27 √ √
WB2X212THR 65 2-1 ⁄ 2" 0.51 √ √
WB2X3THR 80 3" 0.49 √ √
WB2X4THR 50 2" BSP 100 4" 44.5 69.2 0.47 √ √
WB2X6THR 150 6" 0.46 √ √
WB2X8THR 200 8" 0.45 √ √
WB212X3THR 80 3" 0.87 √ √
WB212X4THR 100 4" 0.84 √ √
65 2-1 ⁄ 2" BSP 56.3 81.5
WB212X6THR 150 6" 0.82 √ √
WB212X8THR 200 8" 0.80 √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

8–8
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Branch Outlets
C-Let Threaded
Branch Outlets Non-Chamfered

Sizes DN15 thru DN65

Approvals UL Listed & FM Approved

Material Black Steel to ASTM A-105

Max. Pressure Max. 20.68 Bar [300 Psi] for Sprinkler systems

Tech Data Sheet Contact Tyco for details

C-Let Threaded
Outlet Size Make Approval &
Header for Pipe Size Outlet Inside
Part Female Up Weight Listings
Length Ø
Number M kg
DN In DN in C mm D mm UL FM
mm
CL15025N 1
25-40 1” - 1-1 ⁄ 2” √ √
⁄ 2”
CL15050N 15 50-65 2” - 2-1 ⁄ 2” 25 21 14 0,1 √ √
NPT C
CL15080 80-200 3" - 8” √ √
CL20025N 25-40 1” - 1-1 ⁄ 2” √ √
CL20050N 50 2” √ √ M
3
⁄4 ” D
CL20065N 20 65 2-1 ⁄ 2” 25 25 13 0,1 √ √
NPT
CL20080 80-125 3” - 5” √ √
CL20150 150-200 6” - 8” √ √
CL25032 32-40 1-1 ⁄4” - 1-1 ⁄ 2” √ √
CL25050 50 2” √ √
CL25065 65 2-1 ⁄ 2” √ √
25 1” BSP 28 25 12 0,13
CL25080 80 3” √ √
CL25100 100-125 4” - 5” √ √
CL25150 150-200 6” - 8” √ √
CL32050 50 2” √ √
CL32065 65 2-1 ⁄ 2” √ √
1-1 ⁄4”
CL32080 32 80 3” 32 41 16 0,19 √ √
BSP
CL32100 100-125 4” - 5” √ √
CL32150 150-200 6” - 8” √ √
CL40050 50 2” √ √
CL40065 65 2-1 ⁄ 2” √ √
CL40080 1-1 ⁄ 2” 80 3” √ √
40 32 47 16 0,24
CL40100 BSP 100 4” √ √
CL40125 125-150 5” - 6” √ √
CL40200 200 8” √ √
CL50065 65 2-1 ⁄ 2” √ √
CL50080 80 3” √ √
50 2” BSP 38 59 19 0,38
CL50100 100 4” √ √
CL50150 150-200 6” - 8” √ √
CL65100 100 4” √ √
2-1 ⁄ 2”
CL65150 65 150 6” 45 70 21 0,55 √ √
BSP
CL65200 200 8” √ √

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 8–9
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Branch Outlets
WELDING BRANCHLETS GRV
Branch Outlets Grooved

Sizes DN32 thru DN100

Approvals UL Listed & FM Approved

Material Black Steel to ASTM A-53

Tech Data Sheet Contact Tyco for details

Welding Branchlets Grooved


Grooved Outlet Size Header for Pipe Size Outlet Outside Approval & Listings
Weight
Part Number Length L ØA
DN In DN in kg UL FM
mm mm
WB114X2GRV 50 2” √ √
WB114X3GRV 32 1-1 ⁄4” 80 3” 75,4 42,2 0,24 √ √
WB114X6GRV 150 6” √ √
WB112X2GRV 50 2” √ √
WB112X212GRV 65 2-1 ⁄ 2” √ √
40 1-1 ⁄ 2” 75,4 48,3 0,29
WB112X3GRV 80 3” √ √
WB112X6GRV 150 6” √ √
WB2X212GRV 65 2-1 ⁄ 2” √ √
WB2X3GRV 80 3” √ √
WB2X4GRV 50 2” 100 4” 75,4 60,3 0,41 √ √
WB2X6GRV 150 6” √ √
WB2X8GRV 200 8” √ √
WB212X212GRV 65 2-1 ⁄ 2”
WB212X3GRV 80 3” √ √
WB212X4GRV 65 2-1 ⁄ 2” 100 4” 75,4 73,0 0,60 √ √
WB212X6GRV 150 6” √ √
WB212X8GRV 200 8” √ √
WB3X3GRV 80 3”
WB3X4GRV 100 4” √ √
80 3” 75,4 88,9 0,86
WB3X6GRV 150 6” √ √
WB3X8GRV 200 8” √ √
WB4X4GRV 100 4”
WB4X6GRV 100 4” 150 6” 101,0 114,3 1,73 √ √
WB4X8GRV 200 8” √ √

ØA

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

8–10
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Branch Outlets
PERMABOND A1058
Pipe Thread Sealant

Sizes 250 ml Tube

Approvals WRC Approved

Tech Data Sheet Contact Tyco for details

Permabond A1058 is a highly viscous anaerobic sealant designed for use on threaded metal pipe connections.
The delayed cure allows components to be accurately aligned. Permabond A1058 provides an instant seal and can be applied more
easily and faster than PTFE tape or hemp, saving on installation time.

Model Permabond A1058 - Pipe Thread Sealant


Part Weight Approval & Listings
Description
Number kg WRC
A105825000 Tube 250 ml 0,3 √
A105825010 Box of 10 x 250 ml 3,0 √

Use Instructions:
Wipe male and female threads with a clean, dry rag to remove any grease and dirt.
Apply A1058 to the full circumference of the male thread to 1 and a half thread forms, ensuring that there is
sufficient adhesive to fill the gaps & that it is positioned correctly.
For threaded parts of 4” diameter and above, apply a second bead half inch from the first bead or apply A1058
to both components.
Assemble the joints with tools in the normal way and wipe off any excess from the finished joint.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 8–11
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Branch Outlets
Notes

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

8–12
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Hoses and Hose Reels

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 9–1
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Hose Reels & Cabinets


SWINGING REEL
Swinging Type Hose Reels

Sizes DN25 thru DN33

Approvals EN 671-1

Length 20 m thru 30 m

Tech Data Sheet Contact Tyco for details

Swinging Type Hose Reels


Approval &
Dimensions mm Weight
Part Number DN Length Listings
kg
A B C D EN 671-1
NFGTP25/20 25 20 m 685 700 310 1” F 22 √
NFGTP25/30 25 30 m 685 700 310 1” F 27 √
NFGTP33/20 33 20 m 710 700 445 1-1 ⁄ 2” F 30 √
NFGTP33/30 33 30 m 710 700 445 1-1 ⁄ 2” F 38 √

C B

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

9–2
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Hose Reels & Cabinets
FIXED REEL
Fixed Reel Hose Reels

Sizes DN19 thru DN33

Approvals EN 671-1

Length 20 m thru 30 m

Tech Data Sheet Contact Tyco for details

Fixed Reel Hose Reels


Approval &
Dimensions mm
Weight Listings
Part Number DN Length
G kg
A B C D E F EN 671-1
BSP
3
09000340 19 20 m 220 75 570 770 300 450 ⁄4 ” F 15 √
3
09000300 19 30 m 220 75 570 770 300 450 ⁄4 ” F 18 √
09000350 25 20 m 270 75 570 770 300 450 1" F 20 √
09000310 25 30 m 270 75 570 770 300 450 1" F 125 √
09000430 33 20 m 415 100 570 740 300 450 1-1 ⁄ 2” F 28 √
09000420 33 30 m 415 100 570 740 300 450 1-1 ⁄ 2” F 36 √

C B

1
G

F
4

Parts List
Item
2 No.
Description

1 Hose reel with wall bracket


3 2 Reduction [DN19 only]
3 Supply Piping
4 Main shut-off valve

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 9–3
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Hose Reels & Cabinets


SWINGING REEL IN CABINET
Swinging Reel In Cabinet Hose Reels

Sizes DN19 thru DN25

Approvals EN 671-1

Length 20 m & 30 m

Tech Data Sheet Contact Tyco for details

Swinging Reel In Cabinet Hose Reels


Approval &
Dimensions mm
Weight Listings
Part Number DN Length
F kg
A B C D E EN 671-1
BSP
3
09000360 19 20 m 1330 710 700 285 945 ⁄4 ” F 42 √
3
09000320 19 30 m 1330 710 700 285 945 ⁄4 ” F 45 √
09000370 25 20 m 1330 710 700 285 945 1” F 48 √
09000330 25 30 m 1330 710 700 285 945 1” F 53 √

B
F D E

C
1

Parts List
4
Item
Description
No.
1 Hose Reel Mounted On Door
3 2 Cabinet
4
3 Main Shut-Off Valve
4 System Piping
5 Supply Connection

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

9–4
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Hose Reels & Cabinets
SERIES 2500
Hose Rack Assemblies

Approvals UL Listed & FM Approved

Length 15.2 m thru 30.4 m

Tech Data Sheet Contact Tyco for details

Series 2500 Hose Rack Assemblies

Dimensions mm Approval & Listings


Part Hose Valve Ø Weight
Number Length Size Hose kg
A B C D UL FM
2505 15.2 m 1-1 ⁄ 2” 1-1 ⁄ 2” 597 558 457 102 7 √ √
2507 22.8 m 1-1 ⁄ 2” 1-1 ⁄ 2” 660 622 457 102 9 √ √
2510 30.4 m 1-1 ⁄ 2” 1-1 ⁄ 2” 787 749 457 102 12 √ √

P1 Parts List
C Item
Description
No.
P4
P1 Angle Valve Brass 20.7 Bar
P3 P2 Polyflex Hose 34.5 Bar
P3 Fog nozzle Satin Brass
P4 Hose Rack Red Polyester Coated Steel

A B P2

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 9–5
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Hose Reels & Cabinets


SERIES 1054
Hose Rack Assemblies

Sizes 965 x 660mm

Body Red Polyester Steel with Full glass Door

Tech Data Sheet Contact Tyco for details

Other model available on request [recessed/trimless]

SERIES 1054 Hose Rack Assemblies


Max. Capacity Hose Weight
Part Number Wall Mounting
m kg
1054-A-MOD Surface 30.4 27

152
660

965

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

9–6
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Hoses
VIKING HOSE
Hoses

Sizes DN38 thru DN64

Length 18,3 m thru 30 m

Tech Data Sheet Contact Tyco for details

All Viking hose products are available with international fire hose couplings in light alloy or gunmetal - POA

Viking Hose
Max Advised
Part Internal Average Bend
Length Weight * Working
Number Diameter Burst Pressure Radius
Pressure
10291 38 mm 23m 280 gr/m 22,5 bar 55 bar 65 cm
10293 38 mm 30m 280 gr/m 22,5 bar 55 bar 65 cm
10296 45 mm 18,3m 340 gr/m 22,5 bar 55 bar 80 cm
10300 45 mm 30m 340 gr/m 22,5 bar 55 bar 80 cm
10303 52 mm 20m 400 gr/m 22,5 bar 55 bar 95 cm
10306 52 mm 30m 400 gr/m 22,5 bar 55 bar 95 cm
10309 64 mm 18,3m 520 gr/m 22,5 bar 50 bar 110 cm
10310 64 mm 20m 520 gr/m 22,5 bar 50 bar 110 cm
10311 64 mm 23m 520 gr/m 22,5 bar 50 bar 110 cm
10312 64 mm 25m 520 gr/m 22,5 bar 50 bar 110 cm
10313 64 mm 30m 520 gr/m 22,5 bar 50 bar 110 cm

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 9–7
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Hoses
SAXON HOSE
Hoses

Sizes DN38 thru DN65

Length 18,3 m thru 30 m

Tech Data Sheet Contact Tyco for details

Saxon Hoses
Max Advised
Part Internal Weight * Short Length
Length Working
Number Diameter kg Burst Pressure
Pressure
10466 38 mm 20m 180 gr/m 15 bar 45 bar
10470 38 mm 30m 180 gr/m 15 bar 45 bar
10480 45 mm 18,3m 200 gr/m 15 bar 45 bar
10486 45 mm 23m 200 gr/m 15 bar 45 bar
10492 45 mm 30m 200 gr/m 15 bar 45 bar
10501 52 mm 18,3m 220 gr/m 15 bar 45 bar
10502 52 mm 20m 220 gr/m 15 bar 45 bar
10627 52 mm 30m 220 gr/m 15 bar 45 bar
10633 65 mm 18,3m 310 gr/m 15 bar 45 bar
10634 65 mm 20m 310 gr/m 15 bar 45 bar
10635 65 mm 23m 310 gr/m 15 bar 45 bar
10636 65 mm 25m 310 gr/m 15 bar 45 bar
10637 65 mm 30m 310 gr/m 15 bar 45 bar

*Per metre uncoated (± 4%)


** Per metre coated (± 4%)

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

9–8
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Grooved Piping Products
Designed for use in fire protection systems.

- Reduced Installation Time - Quickly Join Steel Pipe


and Cost Without Welding

- Wide Variety of Couplings - Dampening Noise & Vibration


and Fittings to Suite Your Transmission
Pipe Joining Needs

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 10–1
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Grooved Piping Products


Figure 577
Rigid Coupling
Sizes DN25 thru DN300 (1" thru 12")

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

Maximum Working
24,1 bar (350 psi)
Pressure

Grade “A” EPDM


Pre-Lubricate Gasket -34°C to 66°C (-30°F to 150°F)
Temperature

Tech Data Sheet TFP1854

For use in fire protection systems, the GRINNELL G-FIRE Figure 577 Grooved Rigid Coupling provides a rigid joint by firmly gripping
along the full circumference of the pipe grooves. Figure 577 Grooved Rigid Couplings are a proven dependable method of joining
pipe and are an economical alternative to welding, threading, or using flanges. • It is capable of pressures up to 24,1 bar (350 psi)
depending on pipe size and wall thickness when used in fire protection services. • Also available with tri-seal Grade “E” EPDM
gasket for dry pipe fire protection systems, vacuum systems, and freezer applications.

B C

Issue 03, 04, 07

A
Cert No. 570, 669, 673

For detailed Listing and Approval


information contact
Tyco Fire Protection Products.

Part Number Pipe Size Max.† Max.*‡ Dimensions - mm


Max.† Coupling Approx.
Grade “A” End End
Grade “A” Nominal O.D. Pressures Bolts Size Weight
Tri-Seal Load Gap A B C
Gasket mm mm Bar (Qty 2) mm kg
Gasket kN mm
577MA0034✖ 577AT0034✖ 25 33,7 24,1 2,11 1,5 41 100 42 M10 x 57 0.55
577MA0042✖ 577AT0042✖ 32 42,4 24,1 3,37 1,5 68 112 42 M10 x 57 0.59
577MA0048✖ 577AT0048✖ 40 48,3 24,1 4,41 1,5 74 118 42 M10 x 57 0.68
577MA0060✖ 577AT0060✖ 50 60,3 24,1 6,90 1,5 86 132 43 M10 x 57 0.82
577MA0073✖ 577AT0073✖ 65 73,0 24,1 10,11 1,5 99 143 44 M10 x 57 0.91
577MA0076✖ 577AT0076✖ 65 76,1 24,1 11,01 1,5 102 147 44 M10 x 57 0.91
577MA0089✖ 577AT0089✖ 80 88,9 24,1 14,98 1,5 114 161 44 M10 x 57 1.22
577MA0114✖ 577AT0114✖ 100 114,3 20,7 21,22 1,5 145 191 46 M10 x 57 1.50
577MA0139✖ 577AT0139✖ 125 139,7 20,7 31,71 3,2 173 222 49 M12 x 76 2.41
577MA0141✖ 577AT0141✖ 125 141,3 20,7 32,43 3,2 174 224 49 M12 x 76 2.41
577MA0165✖ 577AT0165✖ 150 165,1 20,7 44,28 3,2 198 248 49 M12 x 76 2.59
577MA0168✖ 577AT0168✖ 150 168,3 20,7 46,00 3,2 215 251 49 M12 x 76 2.68
577MA0219✖ 577AT0219✖ 200 219,1 20,7 77,97 3,2 260 325 61 M16 x 83 5.32
577MA0273✖ 577AT0273✖ 250 ✧ 273,0 20,7 121,00 6,4 318 419 65 M20 x 121 8.86
577MA0324✖ 577AT0324✖ 300 ✧ 323,9 20,7 170,00 6,4 368 470 65 M20 x 121 10.00
✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised finish, or 5 for painted white (RAL 9010) coating
* Maximum available gap between pipe ends, Minimum gap = 0,
† Maximum Pressure and End Load are total from all loads based on standard weight steel pipe, Pressure ratings and end loads may differ
for other pipe materials and/or wall thicknesses, Contact Tyco Technical Services for details,
‡ Max End Gap is for cut grooved standard weight pipe, Values for roll grooved pipe will be half that of cut grooved,
✧ 250mm and 300mm couplings requiring VdS approval, Use GRINNELL Figure #772 Mechanical Coupling
For information on other alternative sizes, contact Tyco Technical Services,
See page 9-6 for gasket information

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

10–2
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Grooved Piping Products
Figure 705

Grooved Flexible Coupling


Sizes DN25 thru DN300 (1" thru 12")

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

Maximum Working
20,7 bar (300 psi)
Pressure

Gasket Grade “A” EPDM: -34°C to 66°C (-30°F to 150°F)


Temperature Grade “E” EPDM: -34°C to 110°C (-30°F to 230°F)

Tech Data Sheet TFP1820

The GRINNELL G-FIRE Figure 705 Flexible Coupling is capable of pressures up to 20,7 bar (300 psi) depending on pipe size and wall
thickness when used in fire protection services. It provides a dependable method of joining pipe and is suitable for use in a variety
of applications. • Provides the needed flexibility to accommodate differential movement. • Also available with tri-seal Grade "E"
EPDM gasket for dry pipe fire protection systems, vacuum systems, and freezer applications.

B C

Issue 03, 04, 07


Cert No. 570, 669, 673
A
For detailed Listing and Approval
information contact
Tyco Fire Protection Products.

Part Number Pipe Size Deflection ‡ Dimensions - mm Coupling


Max.† Max.*‡
Grade “E” Max.† Bolts Approx.
Grade “A” End End Degrees
EPDM Nominal O.D. Pressure Size Weight
EPDM Load Gap Per mm/m A B C
Tri-Seal mm mm bar (Qty 2) kg
Gasket kN mm Coupling
Gasket mm
705MA0034✖ 705MT0034✖ 25 33,7 20,7 1,81 3,3 5° 30' 96,7 56,9 100,1 46,0 M10 x 57 0.6
705MA0042✖ 705MT0042✖ 32 42,4 20,7 2,88 3,3 4° 19' 75,0 65,0 106,4 46,0 M10 x 57 0.7
705MA0048✖ 705MT0048✖ 40 48,3 20,7 3,78 3,3 3° 46' 65,8 69,9 112,8 46,0 M10 x 57 0.7
705MA0060✖ 705MT0060✖ 50 60,3 20,7 5,90 3,3 3° 1' 52,5 82,6 124,0 47,8 M10 x 57 0.8
705MA0073✖ 705MT0073✖ 65 73,0 20,7 8,66 3,3 2° 29' 43,3 93,7 139,7 47,8 M10 x 57 0.9
705MA0076✖ 705MT0076✖ 65 76,1 20,7 9,43 3,3 2° 23' 41,7 101,6 146,10 47,8 M12 x 76 1.4
705MA0089✖ 705MT0089✖ 80 88,9 20,7 12,83 3,3 2° 3' 35,8 111,3 165,1 47,8 M12 x 76 1.4
705MA0108✖ 705MT0108✖ 100 108,0 20,7 18,93 6,4 3° 22' 58,3 139,7 190,5 52,3 M12 x 76 1.9
705MA0114✖ 705MT0114✖ 100 114,3 20,7 21,21 6,4 3° 11' 55,8 144,5 196,9 52,3 M12 x 76 1.8
705MA0133✖ 705MT0133✖ 125 133,0 20,7 28,88 6,4 2° 44' 46,7 166,6 241,3 52,3 M16 x 83 3.3
705MA0139✖ 705MT0139✖ 125 139,7 20,7 31,70 6,4 2° 36' 45,5 173,0 247,7 52,3 M16 x 83 3.3
705MA0141✖ 705MT0141✖ 125 141,3 20,7 32,41 6,4 2° 35' 45,0 174,8 247,7 52,3 M16 x 83 3.2
705MA0159✖ 705MT0159✖ 150 159,0 20,7 40,93 6,4 2° 17' 40,0 192,0 261,9 52,3 M16 x 83 3.4
705MA0165✖ 705MT0165✖ 150 165,1 20,7 44,25 6,4 2° 12' 38,3 196,9 271,5 52,3 M16 x 83 3.2
705MA0168✖ 705MT0168✖ 150 168,3 20,7 45,97 6,4 2° 10' 37,5 201,7 271,5 52,3 M16 x 83 3.2
705MA0219✖ 705MT0219✖ 200 219,1 20,7 77,92 6,4 1° 40' 29,2 258,8 344,4 63,5 M20 x 121 6.6
705MA0273✖ 705MT0273✖ 250 273,0 17,2 100,8 6,4 1° 20' 23,3 322,3 416,1 66,8 M24 x 165 12.7
705MA0324✖ 705MT0324✖ 300 323,9 17,2 141,9 6,4 1° 7' 19,2 379,5 479,6 66,8 M24 x 165 16.6
✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised finish, or 5 for painted white RAL9010 coating
* Maximum available gap between pipe ends. Minimum gap = 0.
† Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ for
other pipe materials and/or wall thickness. Contact Tyco Technical Services for details.
‡ Max end gap and deflection is for cut grooved standard weight pipe. Values for roll grooved pipe will be half that of cut grooved.
For information on other alternative sizes, contact Tyco Technical Services.
See page 9-6 for gasket information

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 10–3
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Grooved Piping Products


Figure 707

Flexible Coupling
Sizes DN32 thru DN300 (1-1 ⁄4" thru 12")

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

Maximum Working
34,5 bar (500 psi)
Pressure

Grade “E” EPDM


-34°C to 110°C (-30°F to 230°F)
Gasket Temperature

Tech Data Sheet TFP1840

The GRINNELL 707 Flexible Coupling provides a dependable method of joining pipe and is suitable for use in a variety of
applications. • Capable of pressures up to 34,5 bar (500 psi) depending on pipe size and wall thickness. • Also available with tri-seal
Grade “E” EPDM gasket for dry pipe fire protection systems, vacuum systems, and freezer applications.

B C
Issue 03, 04, 07
Cert No. 570, 669, 673

For detailed Listing and Approval


information contact
Tyco Fire Protection Products.
A

25mm - 300mm (1" - 12") 350m


Part Number Pipe Size Deflection ‡ Dimensions - mm
Max.‡
Max.† Max.† Coupling Approx.
Grade “E” End Degrees
Grade “E” Nominal O.D. Pressure End Load Gap
Bolts Size Weight
Tri-Seal Bar kN Per mm/m A B C (Qty 2) mm kg
Gasket mm mm mm
Gasket Coupling
707ME0042✖ 707MT0042✖ 32 42,4 20,7 2,89 3,3 4° 19' 75,0 70,0 111,0 46,0 M12 x 76 1.0
707AE0048✖ 707AT0048✖ 40 48,3 34,5 6,31 3,3 3° 46' 65,8 75,4 117,6 46,0 M12 x 76 1.1
707AE0060✖ 707AT0060✖ 50 60,3 34,5 9,85 3,3 3° 1' 52,5 89,9 133,4 47,8 M12 x 76 1.4
707AE0073✖ 707AT0073✖ 65 73,0 34,5 14,4 3,3 2° 29' 43,3 103,1 146,1 47,8 M12 x 76 1.6
707AE0076✖ 707AT0076✖ 65 76,1 20,7 9,435 3,3 2° 23' 41,7 106,4 146,1 47,8 M12 x 76 1.8
707AE0089✖ 707AT0089✖ 80 88,9 34,5 21,4 3,3 2° 3' 35,8 119,1 162,1 47,8 M12 x 76 1.8
707AE0114✖ 707AT0114✖ 100 114,3 34,5 35,4 6,4 3° 11' 55,8 151,1 209,6 52,3 M16 x 83 3.2
707AE0139✖ 707AT0139✖ 125 139,7 34,5 54,1 6,4 2° 30' 43,6 178,3 254,0 51,8 M20 x 121 3.8
707AE0141✖ 707AT0141✖ 125 141,3 34,5 54,1 6,4 2° 35' 45,0 179,8 254,0 52,3 M20 x 121 4.5
707AE0165✖ 707AT0165✖ 150 165,1 20,7 44,3 6,4 2° 12' 38,3 208,0 285,8 52,3 M20 x 121 5.0
707AE0168✖ 707AT0168✖ 150 168,3 34,5 76,7 6,4 2° 10' 37,5 210,8 285,8 52,3 M20 x 121 5.0
707AE0219✖ 707AT0219✖ 200 219,1 34,5 130,0 6,4 1° 40' 29,2 271,3 355,6 62,7 M22 x 165 9.7
707AE0273✖ 707AT0273✖ 250 273,0 34,5 202,0 6,4 1° 20' 23,3 331,7 417,6 66,8 M24 x 165 13.2
707AE0324✖ 707AT0324✖ 300 323,9 34,5 284,0 6,4 1° 7' 19,2 390,9 478,5 66,8 M24 x165 16.8

✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised finish
† Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ for
other pipe materials and/or wall thicknesses. Contact Tyco Technical Services for details.
‡ Max available end gap and deflection is for cut grooved standard weight pipe. Minimum gap = 0.
Values for roll grooved pipe will be half that of cut grooved.
For information on other alternative sizes, contact Tyco Technical Services.
See page 9-6 for gasket information

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

10–4
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Grooved Piping Products
Figure 716
Flexible Reducing Coupling
DN50 x DN40 thru DN200 x DN150
Sizes
(2" x 1-1 ⁄ 2" thru 8" x 6")

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

Maximum Working
24,1 bar (350 psi)
Pressure

Grade “E” EPDM


-34°C to 110°C (-30°F to 230°F)
Gasket Temperature

Tech Data Sheet TFP1830

The GRINNELL G-FIRE 716 Flexible Reducing Coupling allows easy transition between two different pipe sizes and replaces two
couplings and a reducing fitting. • It is capable of pressures up to 24,1 bar (350 psi) depending on pipe size and wall thickness. A
flexible reducing coupling is not recommended for low-temperature applications. • Faster and easier than threading, welding or
using flanges.

B C

Issue 03, 04, 07


Cert No. 570, 669, 673

For detailed Listing and Approval


information contact A
Tyco Fire Protection Products.

Pipe Size Deflection ‡ Dimensions mm


Max.†
Max.*‡ Max.† Coupling Approx.
Part Degrees End
Nominal O.D. End Gap Pressures Bolts Size Weight
Number Per mm/m Load
A B C
mm mm mm Bar (Qty 2) mm kg
Coupling kN.
716AE2015✖ 50 x 40 60,3 x 48,3 24,1 4,412 3,3 1° 53' 32,5 88,9 128,5 47,8 M10 x 57 0.9
716AE2520✖ 65 x 50 73,0 x 60,3 24,1 6,894 3,3 1° 33' 26,7 101,6 139,7 47,8 M10 x 57 1.1
716ME2620✖ 65 x 50 76,1 x 60,3 24,1 6,894 3,3 1° 34' 26,7 106,4 149,4 47,8 M12 x 76 1.4
716AE3020✖ 80 x 50 88,9 x 60,3 24,1 6,894 3,3 1° 17' 22,5 119,1 165,1 47,8 M12 x 76 1.9
716AE3025✖ 80 x 65 88,9 x 73,0 24,1 10,106 3,3 1° 17' 22,5 119,1 165,1 47,8 M12 x 76 2.0
716ME3026✖ 80 x 65 88,9 x 76,1 24,1 11,004 3,3 1° 17' 22,5 119,1 165,1 47,8 M12 x 76 1.9
716AE4220✖ 100 x 50 114,3 x 60,3 24,1 6,894 4,8 2° 38' 45,8 152,4 206,5 50,8 M16 x 83 2.5
716AE4225✖ 100 x 65 114,3 x 73,0 24,1 10,101 4,8 2° 38' 45,8 152,4 206,5 50,8 M16 x 83 2.9
716ME4226✖ 100 x 65 114,3 x 76,1 24,1 11,004 4,8 2° 38' 45,8 152,4 206,5 50,8 M16 x 83 2.9
716AE4230✖ 100 x 80 114,3 x 88,9 24,1 14,977 4,8 2° 38' 45,8 152,4 206,5 50,8 M16 x 83 2.8
716ME5242✖ 125 x 100 139,7 x 114,3 24,1 24,749 6,4 2° 38' 45,8 179,3 241,3 52,3 M20 x 121 4.3
716AE5342✖ 125 x 100 141,3 x 114,3 24,1 24,759 6,4 2° 5' 36,7 181,1 242,8 52,3 M20 x 121 4.4
716ME6242✖ 150 x 100 165,1 x 114,3 20,6 21,222 6,4 1° 50' 31,7 207,8 274,6 52,3 M20 x 121 5.7
716AE6342✖ 150 x 100 168,3 x 114,3 20,6 21,222 6,4 1° 44' 30,0 212,9 276,4 52,3 M20 x 121 5.7
716AE6353✖ 150 x 125 168,3 x 141,3 20,6 32,436 6,4 1° 44' 30,0 212,9 276,4 52,3 M20 x 121 5.2
716AE8063✖ 200 x 150 219,1 x 168,3 20,6 45,999 6,4 1° 15' 21,7 271,5 349,3 57,2 M22 x 165 9.4
✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised finish
* Maximum available gap between pipe ends. Minimum gap = 0.
† Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on
other pipe materials and/or wall thickness. Contact Tyco Technical Services for details.
‡ Max end gap and deflection is for cut grooved standard weight pipe. Values for roll grooved pipe will be half that of cut grooved.
For information on other alternative sizes, contact Tyco Technical Services.
See page 9-7 for gasket information

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 10–5
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Grooved Piping Products


Figure 577, 579, 705, 707

Replacement Gaskets

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

Gasket Grade “A” EPDM: -34°C to 66°C (-30°F to 150°F)


Temperature Grade “E” EPDM: -34°C to 110°C (-30°F to 230°F)

Tech Data Sheet TFP1895

Style C Tri-Seal Center-Stop

Pipe Size EPDM


Grade A
Grade “A”
Nominal O.D. EPDM Grade E Grade E
EPDM
mm mm C-Style Tri-Seal C-Style
Center-Stop Gasket
PreLube Gasket
25 33,7 034EPDMAPL 10EPDM-TRI 10EPDM –
32 42,4 042EPDMAPL 12EPDM-tri 12EPDM 12EPDM579
40 48,3 048EPDMAPL 15EPDM-tri 15EPDM 15EPDM579
50 60,3 060EPDMAPL 20EPDM-tri 20EPDM 20EPDM579
65 73,0 073EPDMAPL 25EPDM-tri 25EPDM 25EPDM579
65 76,1 076EPDMAPL 26EPDM-tri 26EPDM 26EPDM579
80 88,9 089EPDMAPL 30EPDM-tri 30EPDM 30EPDM579
100 108,0 108EPDMAPL 41EPDM-tri 41EPDM –
100 114,3 114EPDMAPL 42EPDM-tri 42EPDM 42EPDM579
125 133,0 133EPDMAPL 51EPDM-tri 51EPDM –
125 139,7 139EPDMAPL 52EPDM-tri 52EPDM 52EPDM579
125 141,3 141EPDMAPL 52EPDM-tri 52EPDM –
150 159,0 159EPDMAPL 61EPDM-tri 61EPDM –
150 165,1 165EPDMAPL 62EPDM-tri 62EPDM 62EPDM579
150 168,3 168EPDMAPL 63EPDM-tri 63EPDM 60EPDM579
200 219,1 219EPDMAPL 80EPDM-tri 80EPDM 80EPDM579
250 273,0 273EPDMAPL 11EPDM-tri 11EPDM –
300 323,9 324EPDMAPL 13EPDM-tri 13EPDM –

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

10–6
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Grooved Piping Products
Figure 716

Replacement Gaskets

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

Grade “E” EPDM


-34°C to 110°C (-30°F to 230°F)
Gasket Temperature

Tech Data Sheet TFP1895

Pipe Size
EPDM Grade E
Nominal O.D. 716-Style
mm mm
50 x 40 60,3 x 48,3 EPDM2015
65 x 50 73,0 x 60,3 EPDM2520
65 x 50 76,1 x 60,3 EPDM2620
80 x 50 88,9 x 60,3 EPDM3020
80 x 65 88,9 x 73,0 EPDM3025
80 x 65 88,9 x 76,1 EPDM3026
100 x 50 114,3 x 60,3 EPDM4220
100 x 65 114,3 x 73,0 EPDM4225
100 x 65 114,3 x 76,1 EPDM4226
100 x 80 114,3 x 88,9 EPDM4230
125 x 100 139,7 x 114,3 EPDM5242
125 x 100 141,3 x 114,3 EPDM5342
150 x 100 165,1 x 114,3 EPDM6242
150 x 100 168,3 x 114,3 EPDM6342
150 x 125 168,3 x 141,3 EPDM6553
200 x 150 219,1 x 168,3 EPDM8063

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 10–7
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Grooved Piping Products


Figure 71
Flange Adapter
Sizes DN50 thru DN300 (2" thru 12")

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

Maximum Working
17,2 bar (250 psi)
Pressure

Grade “E” EPDM


-34°C to 110°C (-30°F to 230°F)
Gasket Temperature

Flange Drilling ANSI Class 125 and 150, or PN16 standards

Tech Data Sheet TFP1880

The GRINNELL 71 Flange Adapter allows for a direct transition from flanged components to a grooved piping system. • Capable of
pressures up to 17,2 bar (250 psi) depending on pipe size and wall thickness.

A C

Issue 03, 04, 07


Cert No. 570, 669, 673

For detailed Listing and Approval


information contact
Tyco Fire Protection Products.
F B E D

- 300mm (2" - 12")


Sizes 50mm Recommended
Pipe Size Max † Dimensions - mm
Flange Mating Bolts ‡ Approx.
Part Flange End
Size Wt.
Number Nominal O.D. Type Load
A B C *D *E F Dia. x Lg Qty. kg
mm mm kN
mm
71dae0060✖ 50 60,3 PN10 / PN16 4,93 162,1 125,0 19,1 60,5 86,6 184,2 M16 x 76 4 1.4
71dae0073✖ 65 76,1 PN10 / PN16 7,86 184,9 145,0 22,4 76,1 102,4 205,5 M16 x 76 4 2.3
71dae0076✖ 80 88,9 PN10 10,70 200,2 160,0 23,9 88,9 115,1 222,3 M16 x 76 4 2.5
71dae0089✖ 80 88,9 PN16 10,70 200,2 160,0 23,9 88,9 115,1 222,3 M16 x 76 8 2.5
71dae0114✖ 100 114,3 PN10 / PN16 17,69 228,6 180,1 23,9 114,3 140,5 251,5 M16 x 76 8 3.2
71dme0139✖ 125 139,7 PN10 / PN16 26,42 249,9 210,1 25,4 139,7 165,9 271,5 M16 x 89 8 4.2
71dae0165✖ 150 165,1 PN10 / PN16 36,90 285,8 240,0 25,4 165,1 191,3 307,8 M20 x 89 8 4.5
71dae0168✖ 150 168,3 PN10 / PN16 38,33 279,4 241,1 25,4 168,1 197,6 301,8 M20 x 89 8 7.5
71dme8219✖ 200 219,1 PN10 64,97 339,9 294,9 28,7 218,9 252,5 363,5 M20 x 89 8 9.9
71dme0219✖ 200 219,1 PN16 64,97 339,9 294,9 28,7 218,9 252,5 363,5 M20 x 89 12 9.9
71dae8273✖ 250 273,0 PN10 100,93 395,2 350,0 30,2 273,1 312,7 419,1 M22 x 102 12 10.2
71dae0273✖ 250 273,0 PN16 100,93 406,4 355,1 30,2 273,1 312,7 428,8 M22 x 102 12 11.0
71dme8324✖ 300 323,9 PN10 141,98 445,0 445,0 31,8 323,9 363,9 420,6 M20 x 102 12 12.5
71dme0324✖ 300 323,9 PN16 141,98 460,2 460,2 31,8 323,9 363,9 486,2 M22 x 102 12 12.7
✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised finish
* Dimensions D and E represent minimum and maximum sealing surfaces.† Maximum end load is total from all loads based on standard
weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Technical Services
for details.
‡ Mating Bolts and Nuts are not supplied. Flange Mating Bolts must be at least SAE J429, Grade 5 or stronger. Bolt lengths are standard;
responsibility lies with the purchaser to verify the correct length for the intended application.
For information on other alternative sizes, contact Tyco Technical Services.
See page 9-11 for gasket information
See page 9-10 for Flange Adapter Washers.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

10–8
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Grooved Piping Products
Figure 71 - ANSI Flange

A C

F B E D

Sizes 50mm - 300mm (2" - 12")

Recommended
Pipe Size Dimensions - mm Flange Mating
Max † Max End Bolts ‡ Approx.
Part
Pressure Load † Wt.
Number Size
Nominal O.D. Bar kN Kg.
A B C *D *E F Dia. x Lg Qty.
mm mm
Inches

71AAe0060✖ 50 60,3 17,2 4,93 162,1 120,7 19,1 60,5 86,6 184,2 5/8 x 3 4 1.4
71AAe0073✖ 65 73,0 17,2 7,22 178,0 140,0 22,0 73,0 99,0 200,0 5/8 x 3 4 2.3
71AAe0076✖ 65 76,1 17,2 9,44 184,9 145,0 22,0 76,1 102,4 205,2 5/8 x 3 4 2.6
71AAe0089✖ 80 88,9 17,2 10,70 190,5 152,4 23,9 88,9 115,1 251,0 5/8 x 3 4 2.5
71AAe0114✖ 100 114,3 17,2 17,69 228,6 190,5 23,9 114,3 140,5 251,5 5/8 x 3 8 3.2
71AAe0139✖ 125 139,7 17,2 31,70 249,9 210,1 25,4 139,7 169,2 270,3 3/4 x 3-1/2 8 4.2
71AAe0141✖ 125 141,3 17,2 27,03 254,0 215,9 25,4 141,2 170,7 289,1 3/4 x 3-1/2 8 4.2
71AAe0165✖ 150 165,1 17,2 44,28 285,0 240,6 25,4 165,1 194,6 307,3 3/4 x 3-1/2 8 5.0
71AAe0168✖ 150 168,3 17,2 38,33 279,4 241,3 25,4 168,1 197,6 301,8 3/4 x 3-1/2 8 4.5
71AAe0219✖ 200 219,1 17,2 64,97 342,9 298,5 28,7 218,9 252,5 365,3 3/4 x 3-1/2 8 7.5
71AAe0273✖ 250 273,0 17,2 100,93 406,4 362,0 30,2 273,1 312,7 428,8 7/8 x 4 12 9.9
71AAe0324✖ 300 323,9 17,2 141,98 482,6 431,8 31,8 323,9 363,5 508,0 7/8 x 4 12 11.0

✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised finish
* Dimensions D and E represent minimum and maximum sealing surfaces.
• Metric segment bolt are available upon request.
† Maximum Pressure and End Load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on
other pipe materials and/or wall thickness. Contact Tyco Technical Services for details.
‡ Mating bolts and nuts are not supplied. Flange mating bolts must be at least SAE J429, Grade 5 or stronger. Bolt lengths are standard;
responsibility lies with the purchaser to verify the correct length for the intended application.
For information on other alternative sizes, contact Tyco Technical Services.
See page 9-11 for gasket information
See page 9-10 for Flange Adapter Washers.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 10–9
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Grooved Piping Products


Flange Adapter Washers

Sizes DN50 thru DN300 (2" thru 12")

Material Stainless steel ASTM A666 Type 304-2B

Flange Drilling ANSI Class 125 and 150, or PN16 standards

Tech Data Sheet Contact Tyco for details

Carbon steel Flange Adapter Washers are required when the Figure 71 Flange Adapter is used against surfaces such as: Rubber
surfaces, Adapting to AWWA cast flanges, Rubber faced wafer valves, Serrated flange surfaces.

Mating Flange
Component
GRINNELL
B A Flange Adapter

C Grooved Pipe Gasket Flange Adapter Washer

Part Number Pipe Size Dimensions - mm


Nominal O.D.
PN10/PN16 ANSI A B C
mm mm
INSDIN060M INS060M 50 60,3 100,1 57,2 3,0
INSDIN073M INS073M 65 73,0 119,1 69,9 3,0
INSDIN076M INS076M 65 76,1 124,2 73,2 3,0
INSDIN089M INS089M 80 88,9 131,8 85,9 3,0
INSDIN114M INS114M 100 114,3 169,9 111,3 3,0
INSDIN139M INS139M 125 139,7 189,2 135,1 3,0
INSDIN141M INS141M 125 141,3 192,0 136,7 3,0
INSDIN165M INS165M 150 165,1 215,1 160,5 3,0
INSDIN168M INS168M 150 168,3 217,4 163,6 3,0
INSDIN219M INS219M 200 219,1 274,6 214,4 3,0
INSDIN273M INS273M 250 273,0 335,0 266,7 3,0
INSDIN324M INS324M 300 323,9 404,9 317,5 3,0

For information on other alternative sizes, contact Tyco Technical Services.


Plate material: stainless steel ASTM A666 Type 304-2B

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

10–10
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Grooved Piping Products
Figure 71

Replacement Gaskets

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

Grade “E” EPDM


-34°C to 110°C (-30°F to 230°F)
Gasket Temperature

Tech Data Sheet TFP1895

This gasket is specifically designed for use with the Figure 71 Flange Adaptor. The gasket has an optimum amount of rubber to
provide a dependable seal between both the pipe and mating surface. The gasket is available in Grade “E” EPDM.

Pipe Size EPDM


Nominal O.D. Grade E
mm mm 71-Style
50 60,3 20EPDM71
65 73,0 25EPDM71
65 76,1 26EPDM71
80 88,9 30EPDM71
100 114,3 42EPDM71
125 139,7 52EPDM71
125 141,3 53EPDM71
150 165,1 62EPDM71
150 168,3 63EPDM71
200 219,1 80EPDM71
250 273,0 11EPDM71
300 323,9 13EPDM71

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 10–11
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Grooved Piping Products


Figure 343 & 344
Flange Adapters (PN10/PN16 BS 4504)

Sizes DN50 thru DN300

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

Flange Drilling PN10/PN16 BS 4504

Tech Data Sheet Contact Tyco for details

E to E

Pipe Size Mating Flange


Approx.
Part Flange E to E
Nominal O.D. Bolt Bolt Size Weight
Number Drilling mm
mm mm Qty. mm Kg.

343F00060✖ 50 60,3 PN10 & PN16 95,0 4 M16 x 65 2.3


343F00076✖ 65 76,1 PN10 & PN16 95,0 4 M16 x 65 3.3
343F00089✖ 80 88,9 PN10 & PN16 100,0 4 M16 x 70 4.0
343F00108✖ 100 108,0 PN10 & PN16 102,0 8 M16 x 70 4.5
343F00114✖ 100 114,3 PN10 & PN16 102,0 8 M16 x 70 4.6
343F00133✖ 125 133,0 PN10 & PN16 105,0 8 M16 x 75 6.0
343F00139✖ 125 139,7 PN10 & PN16 105,0 8 M16 x 75 6.0
343F00159✖ 125 159,0 PN10 & PN16 105,0 8 M16 x 75 7.2
343F00165✖ 150 165,1 PN10 & PN16 105,0 8 M20 x 80 7.2
343F00168✖ 150 168,3 PN10 & PN16 105,0 8 M20 x 80 7.2
344F00219✖ 200 219,1 PN10 112,0 8 M20 x 80 10.2
343F00219✖ 200 219,1 PN16 112,0 12 M20 x 90 10.2
344F00273✖ 250 273,0 PN10 138,0 12 M20 x 90 18.0
343F00273✖ 250 273,0 PN16 138,0 12 M24 x 100 18.0
344F00324✖ 300 323,9 PN10 138,0 12 M20 x 90 22.4
343F00324✖ 300 323,9 PN16 138,0 12 M24 x 100 22.4
✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised finish
For information on other alternative sizes, contact Tyco Technical Services.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

10–12
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Grooved Piping Products
Figure 510

90° Elbows

Sizes DN25 thru DN300 (1" thru 12")

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

End Groove x Groove

Tech Data Sheet TFP1815

Issue 03, 04, 07


Cert No. 570, 669, 673

For detailed Listing and Approval


information contact Pipe Size Approx.
Tyco Fire Protection Products. Part C to E
Nominal O.D. Weight
Number mm
mm mm kg
510A00034✖ 25 33,7 57,2 0.4
510A00042✖ 32 42,4 69,9 0.5
C to E 510A00048✖ 40 48,3 69,9 0.6
510A00060✖ 50 60,3 82,6 0.9
510A00073✖ 65 73,0 95,3 1.3
510A00076✖ 65 76,1 95,3 1.3
510A00089✖ 80 88,9 108,0 1.9
510A00114✖ 100 114,3 127,0 3.2
510A00139✖ 125 139,7 139,7 4.7
510A00165✖ 150 165,1 165,1 6.3
510A00168✖ 150 168,3 165,1 6.9
510A00219✖ 200 219,1 196,9 13.4
510A00273✖ 250 273,0 228,6 23.6
510A00324✖ 300 323,9 254,0 30.1

✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised
finish, and 5 for white paint (RAL 9010) finish
For information on other alternative sizes, contact Tyco Technica

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 10–13
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Grooved Piping Products


Figure 501

45° Elbows

Sizes DN25 thru DN300 (1" thru 12")

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

End Groove x Groove

Tech Data Sheet TFP1815

Issue 03, 04, 07


Cert No. 570, 669, 673

For detailed Listing and Approval


information contact Pipe Size Approx.
Tyco Fire Protection Products. Part C to E
Nominal O.D. Weight
Number mm
mm mm kg1
501A00034✖ 25 33,7 43,2 0.3
C to E
501A00042✖ 32 42,4 44,5 0.4
501A00048✖ 40 48,3 44,5 0.5
501A00060✖ 50 60,3 50,8 0.6
501A00073✖ 65 73,0 57,2 1.0
501A00076✖ 65 76,1 57,2 1.0
501A00089✖ 80 88,9 63,5 1.5
501A00114✖ 100 114,3 76,2 2.5
501A00139✖ 125 139,7 82,6 3.3
501A00165✖ 150 165,1 88,9 4.2
501A00168✖ 150 168,3 88,9 5.1
501A00219✖ 200 219,1 108,0 9.3
501A00273✖ 250 273,0 120,7 13.7
501A00324✖ 300 323,9 133,4 22.0

✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised
finish, and 5 for white paint (RAL 9010) finish
For information on other alternative sizes, contact Tyco Technical
Services.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

10–14
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Grooved Piping Products
Figure 519

Tees

Sizes DN25 thru DN300 (1" thru 12")

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

End Groove x Groove

Tech Data Sheet TFP1815

Issue 03, 04, 07


Cert No. 570, 669, 673

For detailed Listing and Approval Pipe Size Approx


information contact
C to E Part C to E
Tyco Fire Protection Products. Nominal O.D. Weight
Number mm
mm mm Kg
519A00034✖ 25 33,4 57,2 0.5
519A00042✖ 32 42,4 69,9 0.8
519A00048✖ 40 48,3 69,9 1.0
519A00060✖ 50 60,3 82,6 1.3
C to E 519A00073✖ 65 73,0 95,3 2.0
519A00076✖ 65 76,1 95,3 2.0
519A00089✖ 80 88,9 108,0 3.0
519A00114✖ 100 114,3 127,0 4.3
519A00139✖ 125 139,7 139,7 6.3
519A00141✖ 125 141,3 127,0 6.4
519A00165✖ 150 165,1 165,1 8.9
519A00168✖ 150 168,3 165,1 10.2
519A00219✖ 200 219,1 196,9 18.1
519A00273✖ 250 273,0 228,6 29.1
519A00324✖ 300 323,9 254,0 49.9

✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised
finish, and 5 for white paint (RAL 9010) finish
For information on other alternative sizes, contact Tyco Technical
Services.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 10–15
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Grooved Piping Products


Figure 260

End Caps

Sizes DN25 thru DN300 (1" thru 12")

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

End Groove x Groove

Tech Data Sheet TFP1815

Issue 03, 04, 07


Cert No. 570, 669, 673

For detailed Listing and Approval


E to E Pipe Size Approx
information contact Part E to E
Tyco Fire Protection Products. Nominal O.D. Weight
Number mm
mm mm Kg
260m00034✖ 25 33,4 21,1 0.1
260m00042✖ 32 42,4 21,1 0.1
260m00048✖ 40 48,3 21,1 0.2
NPT 260M00060✖ 50 60,3 23,4 0.3
260M00073✖ 65 73,0 23,4 0.5
260M00076✖ 65 76,1 21,8 0.6
260M00089✖ 80 88,9 23,4 0.6
260M00114✖ 100 114,3 25,4 1.2
260M00139✖ 125 139,7 23,4 2.1
260M00141✖ 125 141,3 25,4 2.3
260M00159✖ 125 159,0 25,0 3.8
260M00165✖ 150 165,1 23,4 2.9
260M00168✖ 150 168,3 25,4 2.8
260M00219✖ 200 219,1 27,0 3.2
260m00273✖ 250 273,0 25,8 11.1
260m00324✖ 300 323,9 25,8 14.1
✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised
finish, and 5 for white paint (RAL 9010) finish
For information on other alternative sizes, contact Tyco Technical
Services.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

10–16
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Grooved Piping Products
Figure 510S

Short Pattern 90° Elbows

Sizes DN50 thru DN200 (2" thru 8")

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

End Groove x Groove

Tech Data Sheet TFP1815

Pipe Size Approx.


Part C to E
Issue 03, 04, 07
Nominal O.D. Weight
Cert No. 570, 669, 673
Number mm
For detailed Listing and Approval mm mm kg
information contact
510SA0060✖ 50 60,3 69,9 0.7
Tyco Fire Protection Products. C to E
510SA0073✖ 65 73,0 76,2 1.0
510SA0076✖ 65 76,1 76,2 1.0
C to E
510SA0089✖ 80 88,9 85,9 1.4
510SA0114✖ 100 114,3 101,6 2.3
510SA0139✖ 125 139,7 124,0 3.9
510SA0141✖ 125 141,3 123,0 4.3
510SA0165✖ 150 165,1 139,7 5.2
510SA0168✖ 150 168,3 139,7 5.5
510SA0219✖ 200 219,1 174,8 10.1
✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised
finish, and 5 for white paint (RAL 9010) finish
For information on other alternative sizes, contact Tyco Technical
Services.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 10–17
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Grooved Piping Products


Figure 519S

Short Pattern Tees

Sizes DN50 thru DN200 (2" thru 8")

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

End Groove x Groove

Tech Data Sheet TFP1815

C to E
Pipe Size
Approx
Issue 03, 04, 07
Part C to E
Cert No. 570, 669, 673
Nominal O.D. Weight
For detailed Listing and Approval Number mm
mm mm Kg
information contact
Tyco Fire Protection Products.
C to E 519SA0060✖ 50 60,3 69,9 1.2
519SA0073✖ 65 73,0 76,2 2.0
519SA0076✖ 65 76,1 76,2 1.4
519SA0089✖ 80 88,9 85,9 3.0
519SA0114✖ 100 114,3 101,6 4.9
519SA0139✖ 125 139,7 124,0 5.0
519SA0141✖ 125 141,3 123,0 5.3
519SA0165✖ 150 165,1 139,7 6.7
519SA0168✖ 150 168,3 139,7 6.8
519SA0219✖ 200 219,1 174,8 18.1
✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised
finish, and 5 for white paint (RAL 9010) finish
For information on other alternative sizes, contact Tyco Technical
Services.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

10–18
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Grooved Piping Products
Figure 212 / 312

22-1 ⁄ 2° Elbows

Sizes DN32 thru DN300 (1-1 ⁄4" thru 12")

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

End Groove x Groove

Tech Data Sheet TFP1815

Pipe Size Figure 212 / 312


C to E
Approx.
Nominal O.D. Part C to E
Issue 03, 04, 07
Weight
Cert No. 570, 669, 673
mm mm Number mm
For detailed Listing and Approval Kg.
information contact 32 42,4 212A00042✖ 44,5 0.2
Tyco Fire Protection Products.
40 48,3 212A00048✖ 44,5 0.2
50 60,3 212A00060✖ 47,8 0.3
65 73,0 312A00073✖ 50,8 0.3
65 76,1 212M00076✖ 50,8 0.5
80 88,9 212A00089✖ 57,2 0.6
100 114,3 212A00114✖ 66,8 1.1
125 139,7 212M00139✖ 73,2 1.1
125 141,3 312A00141✖ 73,2 1.9
150 165,1 312F00165✖ 79,5 2.0
150 168,3 212A00168✖ 79,5 2.5
200 219,1 312A00219✖ 98,6 5.0
250 273,0 312F00273✖ 111,3 6.4
300 323,9 312F00324✖ 124,0 10.0

✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised finish
For information on other alternative sizes, contact Tyco Technical Services.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 10–19
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Grooved Piping Products


Figure 211 / 311

11-1 ⁄4° Elbows

Sizes DN32 thru DN300 (1-1 ⁄4" thru 12")

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

End Groove x Groove

Tech Data Sheet TFP1815

Pipe Size Figure 211 /311 - Cast or Fabricated


C to E
Approx.
Nominal O.D. Part C to E
Weight
Issue 03, 04, 07 mm mm Number mm
Cert No. 570, 669, 673
Kg.
For detailed Listing and Approval
information contact
32 42,4 211A00042✖ 35,1 0.2
Tyco Fire Protection Products. 40 48,3 211A00048✖ 35,1 0.2
50 60,3 211A00060✖ 35,1 0.3
65 73,0 311A00073✖ 38,1 0.5
65 76,1 211M00076✖ 38,1 0.5
80 88,9 211A00089✖ 38,1 0.5
100 114,3 211A00114✖ 44,5 1.0
125 139,7 211M00139✖ 50,8 1.0
125 141,3 311A00141✖ 50,8 1.5
150 165,1 211M00165✖ 50,8 1.6
150 168,3 211A00168✖ 50,8 2.1
200 219,1 311A00219✖ 50,8 3.9
250 273,0 311F00273✖ 54,1 4.1
300 323,9 311F00324✖ 57,2 7.6

✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised finish
For information on other alternative sizes, contact Tyco Technical Services.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

10–20
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Grooved Piping Products
Figure 221 / 321

Reducing Tees

DN50 x DN50 x DN25 thru DN300 x DN30 x DN250


Sizes
(2" x 2" x 1" thru 12" x 12" x 10")
Figure 321
Reducing Tee Approvals UL, ULC Listed & FM, VdS, & LPCB Approved
Fabricated

End Groove x Groove


Figure 221
Reducing Tee Maximum Working
Cast 20,7 bar (300 psi)
Pressure

Tech Data Sheet TFP1815

C to E C to E
Issue 03, 04, 07
Cert No. 570, 669, 673

For detailed Listing and Approval


information contact
Tyco Fire Protection Products.

C to E C to E

Figure 221 Figure 321


Reducing Tee Cast Reducing Tee Fabricated

Pipe Size Figure 221 - Cast Figure 321 - Fabricated


Approx. Approx.
Nominal O.D. Part C to E Part C to E
Weight Weight
mm mm Number mm Number mm
Kg. Kg.
50 x 50 x 25 60,3 x 60,3 x 33,7 – – – 321F02010✖ 82,6 0,9
50 x 50 x 40 60,3 x 60,3 x 48,3 221M02015✖ 82,6 1,2 321F02015✖ 82,6 0,9
65 x 65 x 50 73,0 x 73,0 x 60,3 221M02520✖ 95,3 1,9 321F02520✖ 95,3 2,0
65 x 65 x 40 76,1 x 76,1 x 48,3 221M02615✖ 95,3 2,0 321F02615✖ 95,3 1,9
65 x 65 x 50 76,1 x 76,1 x 60,3 221M02620✖ 95,3 2,0 – – –
80 x 80 x 25 88,9 x 88,9 x 33,7 221M03010✖ 108,0 2,5 321F03010✖ 108,0 2,7
80 x 80 x 50 88,9 x 88,9 x 60,3 221M03020✖ 108,0 2,7 321F03020✖ 108,0 2,9
80 x 80 x 65 88,9 x 88,9 x 73,0 221M03025✖ 108,0 2,8 321F03025✖ 108,0 2,9
80 x 80 x 65 88,9 x 88,9 x 76,1 221M03026✖ 108,0 2,7 321F03026✖ 108,0 3,0
100 x 100 x 50 114,3 x 114,3 x 60,3 221M04220✖ 127,0 4,1 – – –
100 x 100 x 65 114,3 x 114,3 x 73,0 221M04225✖ 127,0 4,3 – – –
100 x 100 x 65 114,3 x 114,3 x 76,1 221M04226✖ 127,0 4,3 321F04226✖ 127,0 5,1
100 x 100 x 80 114,3 x 114,3 x 88,9 221M04230✖ 127,0 4,4 321F04230✖ 127,0 5,2
125 x 125 x 65 139,7 x 139,7 x 76,1 – – – 321F05226✖ 139,7 6,9
125 x 125 x 80 139,7 x 139,7 x 88,9 221M05230✖ 139,7 6,4 321F05230✖ 139,7 5,5
125 x 125 x 100 139,7 x 139,7 x 114,3 221M05242✖ 139,7 6,3 321F05242✖ 139,7 7,4
150 x 150 x 50 165,1 x 165,1 x 60,3 – – – 321F06220✖ 165,1 10,4
150 x 150 x 65 165,1 x 165,1 x 76,1 – – – 321F06226✖ 165,1 10,7
150 x 150 x 80 165,1 x 165,1 x 88,9 221M06230✖ 165,1 9,5 321F06230✖ 165,1 10,0
150 x 150 x 100 165,1 x 165,1 x 114,3 221M06242✖ 165,1 9,9 321F06242✖ 165,1 10,3
150 x 150 x 50 168,3 x 168,3 x 60,3 221M06320✖ 165,1 8,8 321F06220✖ 165,1 10,4

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 10–21
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Grooved Piping Products


Figure 221 / 321 - Reducing Tees

C to E
C to E

C to E C to E

Figure 221 Figure 321


Reducing Tee Cast Reducing Tee Fabricated

Pipe Size Figure 221 - Cast Figure 321 - Fabricated


Approx. Approx.
Nominal O.D. Part C to E Part C to E
Weight Weight
mm mm Number mm Number mm
Kg. Kg.
150 x 150 x 65 168,3 x 168,3 x 73,0 221M06325✖ 165,1 9,8 321F06226✖ 165,1 10,6
150 x 150 x 65 168,3 x 168,3 x 76,1 221M06326✖ 165,1 9,8 321F06226✖ 165,1 10,7
150 x 150 x 80 168,3 x 168,3 x 88,9 221M06330✖ 165,1 9,5 321F06330✖ 165,1 10,0
150 x 150 x 100 168,3 x 168,3 x 114,3 221M06342✖ 165,1 9,9 321F06342✖ 165,1 10,8
150 x 150 x 125 168,3 x 168,3 x 139,7 221M06352✖ 165,1 10,4 321F06352✖ 165,1 10,9
200 x 200 x 100 219,1 x 219,1 x 114,3 221A08042✖ 196,9 16,9 321F08042✖ 196,9 16,5
200 x 200 x 125 219,1 x 219,1 x 139,7 221M08052✖ 196,9 17,1 321F08052✖ 196,9 16,6
200 x 200 x 150 219,1 x 219,1 x 165,1 221M08062✖ 196,9 17,1 321F08062✖ 196,9 17,7
200 x 200 x 150 219,1 x 219,1 x 168,3 221A08063✖ 196,9 17,1 321F08063✖ 196,9 17,7
250 x 250 x 100 273,0 x 273,0 x 114,3 221M01142✖ 228,6 29,9 321F01142✖ 228,6 26,2
250 x 250 x 125 273,0 x 273,0 x 139,7 – – – 321F01152✖ 228,6 26,3
250 x 250 x 150 273,0 x 273,0 x 168,3 221M01163✖ 228,6 30,8 321F01162✖ 228,6 28,1
250 x 250 x 200 273,0 x 273,0 x 219,1 221M01180✖ 228,6 31,8 321F01180✖ 228,6 28,6
300 x 300 x 80 323,9 x 323,9 x 88,9 – – – 321F01330✖ 254,0 36,4
300 x 300 x 100 323,9 x 323,9 x 114,3 – – – 321F01342✖ 254,0 36,6
300 x 300 x 125 323,9 x 323,9 x 139,7 – – – 321F01352✖ 254,0 37,4
300 x 300 x 150 323,9 x 323,9 x 165,1 – – – 321F01362✖ 254,0 36,2
300 x 300 x 150 323,9 x 323,9 x 168,3 – – – 321F01363✖ 254,0 36,2
300 x 300 x 200 323,9 x 323,9 x 219,1 – – – 321F01380✖ 254,0 34,6
300 x 300 x 250 323,9 x 323,9 x 273,0 – – – 321F01311✖ 254,0 35,2

✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised finish
For information on other alternative sizes, contact Tyco Technical Services.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

10–22
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Grooved Piping Products
Figure 250 / 350

Concentric Reducers

DN32 x DN25 thru DN300 x DN250


Sizes
(1-1 ⁄4" x 1" thru 12" x 10")
Figure 350
Concentric Reducer
Fabricated Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

End Groove x Groove

Figure 250
Concentric Reducer Maximum Working
20,7 bar (300 psi)
Cast Pressure

Tech Data Sheet TFP1815

E to E E to E

Issue 03, 04, 07


Cert No. 570, 669, 673

For detailed Listing and Approval


information contact
Tyco Fire Protection Products. Figure 250 Figure 350
Concentric Reducer Cast Concentric Reducer Fabricated

Pipe Size Figure 250 - Cast Figure 350 - Fabricated


Approx. Approx.
Nominal O.D. Part E to E Part E to E
Weight Weight
mm mm Number mm Number mm
kg kg
32 x 25 42,4 x 33,7 250M01210✖ 63,5 0,3 – – –
40 x 25 48,3 x 33,7 250M01510✖ 63,5 0,3 – – –
40 x 32 48,3 x 42,4 250A01512✖ 63,5 0,3 350F01512✖ 63,5 0,2
50 x 25 60,3 x 33,7 250M02010✖ 63,5 0,4 – – –
50 x 32 60,3 x 42,4 250M02012✖ 63,5 0,4 – – –
50 x 40 60,3 x 48,3 250M02015✖ 63,5 0,4 – – –
65 x 50 73,0 x 60,3 250M02520✖ 63,5 0,6 – – –
65 x 25 76,1 x 33,7 – – – 350F02610✖ 63,5 0,4
65 x 32 76,1 x 42,4 250M02612✖ 63,5 0,6 350F02612✖ 63,5 0,4
65 x 40 76,1 x 48,3 250M02615✖ 63,5 0,6 – – –
65 x 50 76,1 x 60,3 250M02620✖ 63,5 0,7 – – –
80 x 40 88,9 x 48,3 250A03015✖ 63,5 0,8 – – –
80 x 50 88,9 x 60,3 250M03020✖ 63,5 0,8 – – –
80 x 65 88,9 x 73,0 250M03025✖ 63,5 0,8 – – –
80 x 65 88,9 x 76,1 250M03026✖ 63,5 0,9 – – –
100 x 50 114,3 x 60,3 250M04220✖ 76,2 1,1 – – –
100 x 65 114,3 x 73,0 250M04225✖ 76,2 1,2 – – –
100 x 65 114,3 x 76,1 250M04226✖ 76,2 1,5 350F06226✖ 76,2 1,0
100 x 80 114,3 x 88,9 250M04230✖ 76,2 1,3 – – –
100 x 108 114,3 x 108,0 – – – 350F04241✖ 76,2 1,5
125 x 80 139,7 x 88,9 250M05230✖ 88,9 1,9 – – –
125 x 100 139,7 x 114,3 250M05242✖ 88,9 2,0 – – –
125 x 100 141,3 x 114,3 250M05342✖ 88,9 2,0 – – –
150 x 80 165,1 x 88,9 250M06230✖ 101,6 2,5 – – –
150 x 100 165,1 x 114,3 250M06242✖ 101,6 2,7 – – –

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 10–23
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Grooved Piping Products


Figure 250 / 350 - Concentric Reducers
E to E E to E

Figure 250 Figure 350


Concentric Reducer Cast Concentric Reducer Fabricated

Pipe Size Figure 250 - Cast Figure 350 - Fabricated


Approx. Approx.
Nominal O.D. Part E to E Part E to E
Weight Weight
mm mm Number mm Number mm
kg kg
150 x 125 165,1 x 139,7 250M06252✖ 101,6 2,5 – – –
150 x 50 168,3 x 60,3 250M06320✖ 101,6 2,4 – – –
150 x 65 168,3 x 76,1 250M06326✖ 101,6 2,7 – – –
150 x 80 168,3 x 88,9 250A06330✖ 101,6 2,6 350F06330✖ 101,6 2,7
150 x 100 168,3 x 114,3 250M06342✖ 101,6 2,7 – – –
150 x 125 168,3 x 139,7 250M06352✖ 101,6 2,3 – – –
150 x 125 168,3 x 141,3 250M06353✖ 101,6 2,8 – – –
150 x 159 168,3 x 159,0 – – – 350F06361✖ 101,6 2,9
150 x 150 168,3 x 165,1 – – – 350F06362✖ 101,6 2,9
200 x 80 219,1 x 88,9 – – – 350F08030✖ 127,0 4,9
200 x 100 219,1 x 114,3 250A08042✖ 127,0 4,9 350F08042✖ 127,0 4,9
200 x 125 219,1 x 139,7 250M08052✖ 127,0 4,5 – – –
200 x 125 219,1 x 141,3 – – – 350F08053✖ 127,0 5,1
200 x 150 219,1 x 165,1 250M08062✖ 127,0 5,0 – – –
200 x 150 219,1 x 168,3 250A08063✖ 127,0 5,1 350F08063✖ 127,0 5,1
250 x 100 273,0 x 114,3 – – – 350F01142✖ 152,4 9,3
250 x 150 273,0 x 165,1 250M01162✖ 152,4 8,0 – – –
250 x 150 273,0 x 168,3 250A01163✖ 152,4 7,4 350F01163✖ 152,4 8,8
250 x 200 273,0 x 219,1 250A01180✖ 152,4 8,3 350F01180✖ 152,4 7,8
300 x 100 323,9 x 114,3 – – – 350F01342✖ 177,8 12,5
300 x 150 323,9 x 165,1 – – – 350F01362✖ 177,8 12,7
300 x 150 323,9 x 168,3 – – – 350F01363✖ 177,8 12,7
300 x 200 323,9 x 219,1 250A01380✖ 177,8 11,7 350F01380✖ 177,8 12,9
300 x 250 323,9 x 273,0 250A01311✖ 177,8 12,8 350F01311✖ 177,8 12,8
✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised finish
For information on other alternative sizes, contact Tyco Technical Services.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

10–24
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Grooved Piping Products
Figure 322

Reducing Tees

DN50 x DN50 x DN50 thru DN100 x DN100 x DN65


Sizes
(2" x 2" x 2" thru 4" x 4" x 76,1mm)

End Groove x Groove x Female BSP Thread

Tech Data Sheet Contact Tyco for details

C to E

C to E

Pipe Size C to GE & Approx.


Part
Nominal O.D. C to TE Weight
Number
mm mm mm Kg.
322F020202 50 x 50 x 50 60,3 x 60,3 x 60,3 ISO R7 82,6 1.2
322F026202 65 x 65 x 50 76,1 x 76,1 x 60,3 ISO R7 95,2 1.8
322F026252 65 x 65 x 50 76,1 x 76,1 x 76,1 ISO R7 95,2 1.9
322F030202 80 x 80 x 50 88,9 x 88,9 x 60,3 ISO R7 108,0 2.2
322F030252 80 x 80 x 65 88,9 x 88,9 x 73,0 ISO R7 108,0 2.3
322F042202 100 x 100 x 50 114,3 x 114,3 x 60,3 ISO R7 127,0 2.6
322F042262 100 x 100 x 65 114,3 x 114,3 x 76,1 ISO R7 127,0 2.8
Only available in hot dipped galvanised finish.
For information on other alternative sizes, contact Tyco Technical Services.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 10–25
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Grooved Piping Products


Figure 222

Hydrant Tee

Sizes DN100 (4")

End Groove x Groove

Tech Data Sheet Contact Tyco for details

Pipe Size
Hydrant Max. Working Approx.
Part Nominal Pipe A B C
Outlet Pressure Weight
Number Size OD mm mm mm
ISO bar Kg.
mm mm
222V42262 100 114,3 R7 20,7 190 70 133 4.6
Available in hot dipped galvanizing only.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

10–26
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Grooved Piping Products
Figure 522
G-FIRE Threaded Sprinkler Outlet
Run Sizes DN25 thru DN65 (1" thru 2-1 ⁄ 2")

Outlet Sizes DN10 thru DN25 (3 ⁄ 8" thru 1")

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

Maximum Working
20,7 bar (300 psi)
Pressure

Grade “E” EPDM


-34°C to 110°C (-30°F to 230°F)
Gasket Temperature

Tech Data Sheet TFP1865

The GRINNELL Figure 522 Sprinkler Outlet is an economical alternative to welded pipe outlets on steel pipe. • The Figure 522
Sprinkler Outlet may be used with full lengths of pipe and eliminates threading and welding, decreasing waste and installation
time. • The Figure 522 Sprinkler Outlet may be used in wet pipe, dry pipe, and deluge systems.

B C

A
Issue 03, 04, 07
D
Cert No. 570, 669, 673

For detailed Listing and Approval


information contact E
Tyco Fire Protection Products.

Nominal Pipe Size Outlet Size Max.‡ Dimensions - mm Approx.


Part ISO 7/1 or Outlet
Size O.D. Weight
Number NPT Threads End Load A B C D E
mm mm kg
mm kN
522F1005✖ 15 0,738 25,4 86,4 49,3 14,3 25,4 0.4
522F1007✖ 25 33,7 20 1,156 41,7 86,4 49,3 29,0 25,4 0.5
522F1010✖ 25 1,156 46,5 86,4 57,2 32,0 25,4 0.5
522F1203✖ 10 0,738 31,0 96,0 57,2 23,1 26,9 0.4
522F1205✖ 15 0,738 31,0 96,0 57,2 19,8 26,9 0.4
32 42,4
522F1207✖ 20 1,156 46,5 96,0 57,2 33,8 26,9 0.5
522F1210✖ 25 1,81 50,8 96,0 57,2 36,6 26,9 0.6
522F1505✖ 15 0,738 33,5 101,6 57,2 22,4 31,8 0.5
522F1507✖ 40 48,3 20 1,156 49,0 101,6 57,2 36,3 31,8 0.5
522F1510✖ 25 1,81 53,6 101,6 57,2 39,4 31,8 0.6
522F2005✖ 15 0,738 39,6 113,3 57,2 28,4 38,1 0.6
522F2007✖ 50 60,3 20 1,156 55,1 113,3 57,2 42,4 38,1 0.7
522F2010✖ 25 1,81 60,0 113,3 63,5 45,5 38,1 0.7
522F2605✖ 15 0,738 50,8 130,0 57,2 39,6 46,2 0.7
522F2607✖ 65 76,1 20 1,156 63,5 130,0 57,2 50,8 46,2 0.8
522F2610✖ 25 1,81 69,9 130,0 63,5 55,6 46,2 0.8
✖ = 1 for red paint (RAL 3000) finish, 2 for Geomet finish
See page 9-32 for gasket information.
Available with BSP or NPT threads. Contact Tyco Technical Services for details.
Each branch connection can be made by drilling a one size hole: 24.0mm; +0.5mm/-0.0mm, with the exception of 50 x 25mm and 76.1 x
25mm which requires a hole with diameter 34.9 mm; +0.5 / -0.0 mm.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 10–27
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Grooved Piping Products


Figure 730
Mechanical Tees BSP Threads

Run Sizes DN50 thru DN200 (2" thru 8")

Branch Sizes DN15 thru DN80 outlets (1 ⁄ 2" thru 3")

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

Maximum Working
20,7 bar (300 psi)
Pressure

Grade “E” EPDM


-34°C to 110°C (-30°F to 230°F)
Gasket Temperature

Tech Data Sheet TFP1860

The GRINNELL 730 Mechanical Tees & Crosses come with threaded or grooved outlets and can be used for any tee connection
where a threaded or grooved outlet is needed. • It can be used in place of a tee, a cross connection, or a welded outlet where a
threaded or grooved outlet is needed. • The Mechanical Tee is ideal for use in retrofit or equipment hookup installations as it can be
positioned along the pipe at the proper location in the field, ensuring exact lineup of the branch outlet connection.

C
Issue 03, 04, 07
Cert No. 570, 669, 673
B
For detailed Listing and Approval
information contact A D
Hole
Tyco Fire Protection Products.

Dia. Takeout
E

Nominal Size Hole Dia.† Dimensions - mm Bolt Approx.


Part
Run x Branch Min. Max. Size Weight
Number A B C D E
mm mm mm mm kg
730AT2005✖ 50 x 15 38,1 41,3 66,5 124,0 78,0 53,8 40,4 M10 x 57 1,1
730AT2007✖ 50 x 20 38,1 41,3 66,5 124,0 78,0 53,8 40,4 M10 x 57 1,0
730AT2010✖ 50 x 25 38,1 41,3 66,5 124,0 78,0 53,8 40,4 M10 x 57 1,0
730AT2012✖ 50 x 32 44,5 47,6 70,6 124,0 84,3 49,0 40,4 M10 x 57 1,1
730AT2015✖ 50 x 40 44,5 47,6 69,9 124,0 84,3 49,0 40,4 M10 x 57 1,1
730AT2505✖ 65 x 15 38,1 41,3 73,2 133,4 78,0 60,5 46,0 M10 x 57 1,1
730AT2507✖ 65 x 20 38,1 41,3 73,2 133,4 78,0 60,5 46,0 M10 x 57 1,1
730AT2510✖ 65 x 25 38,1 41,3 73,2 133,4 78,0 60,5 46,0 M10 x 57 1,1
730AT2512✖ 65 x 32 50,8 54,0 76,2 133,4 90,4 55,6 46,0 M10 x 57 1,1
730AT2515✖ 65 x 40 50,8 54,0 78,0 133,4 91,2 55,1 46,0 M10 x 57 1,2
730MT2520✖ 65 x 50 50,8 54,0 81,0 133,4 101,6 62,0 46,0 M10 x 57 1,2
730AT2605✖ 65 x 15 38,1 41,3 74,5 142,7 78,0 62,0 47,5 M10 x 57 1,1
730AT2607✖ 65 x 20 38,1 41,3 74,5 142,7 78,0 62,0 47,5 M10 x 57 1,1
730AT2610✖ 65 x 25 38,1 41,3 74,5 142,7 78,0 62,0 47,5 M10 x 57 1,1
730MT2612✖ 65 x 32 50,8 54,0 77,7 142,7 90,4 57,2 47,5 M10 x 57 1,5
730MT2615✖ 65 x 40 50,8 54,0 79,5 142,7 90,4 57,2 47,5 M10 x 57 1,6
730MT2620✖ 65 x 50 50,8 54,0 82,6 142,7 101,6 63,5 47,5 M10 x 57 1,7
730MT3005✖ 80 x 15 38,1 41,3 81,0 155,7 78,0 65,0 56,1 M12 x 76 1,7
730MT3007✖ 80 x 20 38,1 41,3 81,0 155,7 78,0 65,0 56,1 M12 x 76 1,7

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

10–28
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Grooved Piping Products
Figure 730 - Mechanical Tees BSP Threads

C
B

A D
Hole
Dia. Takeout
E

Nominal Size Hole Dia.† Dimensions - mm Bolt Approx.


Part
Run x Branch Min. Max. Size Weight
Number A B C D E
mm mm mm mm kg
730MT3010✖ 80 x 25 38,1 41,3 81,0 155,7 78,0 65,0 56,1 M12 x 76 1,7
730MT3012✖ 80 x 32 44,5 47,6 84,8 155,7 84,3 63,5 56,1 M12 x 76 1,7
730MT3015✖ 80 x 40 50,8 54,0 85,9 155,7 90,4 63,0 56,1 M12 x 76 1,7
730MT3020✖ 80 x 50 63,5 66,7 88,9 155,7 103,9 69,9 56,1 M12 x 76 2,1
730MT4205✖ 100 x 15 38,1 41,3 93,7 181,1 78,0 77,7 70,6 M12 x 76 2,2
730MT4207✖ 100 x 20 38,1 41,3 93,7 181,1 78,0 77,7 70,6 M12 x 76 2,2
730MT4210✖ 100 x 25 38,1 41,3 93,7 181,1 78,0 77,7 70,6 M12 x 76 2,2
730AT4212✖ 100 x 32 44,5 47,6 99,6 181,1 84,3 76,2 70,6 M12 x 76 2,2
730AT4215✖ 100 x 40 50,8 54,0 101,6 181,1 90,4 75,7 70,6 M12 x 76 2,3
730MT4220✖ 100 x 50 63,5 66,7 101,6 181,1 103,1 82,6 70,6 M12 x 76 2,5
730MT4226✖ 100 x 65 69,9 73,0 101,6 181,1 111,3 79,2 70,6 M12 x 76 2,8
730MT4230✖ 100 x 80 88,9 92,1 104,9 181,1 130,3 84,1 70,6 M12 x 76 3,5
730MT5315✖ 125 x 40 50,8 54,0 117,6 206,5 90,4 101,6 85,6 M16 x 121 3,5
730MT5320✖ 125 x 50 63,5 66,7 117,6 206,5 103,1 98,6 85,6 M16 x 121 3,5
730MT5326✖ 125 x 65 69,9 73,0 120,7 206,5 111,3 98,6 85,6 M16 x 121 4,0
730MT5330✖ 125 x 80 88,9 92,1 127,0 206,5 130,3 103,1 85,6 M16 x 121 5,8
730MT6212✖ 150 x 32 50,8 54,0 130,3 235,0 90,4 108,0 99,1 M16 x 121 3,5
730AT6215✖ 150 x 40 50,8 54,0 130,3 235,0 90,4 102,6 99,1 M16 x 121 3,5
730AT6220✖ 150 x 50 63,5 66,7 130,3 235,0 103,1 109,5 99,1 M16 x 121 3,7
730AT6226✖ 150 x 65 69,9 73,0 130,3 235,0 111,3 106,2 99,1 M16 x 121 4,1
730AT6230✖ 150 x 80 88,9 92,1 139,7 235,0 130,3 111,0 99,1 M16 x 121 4,8
730MT6312✖ 150 x 32 50,8 54,0 130,3 235,0 90,4 108,0 99,1 M16 x 121 3,4
730AT6315✖ 150 40 50,8 54,0 130,3 235,0 90,4 102,6 99,1 M16 x 121 3,4
730AT6320✖ 150 x 50 63,5 66,7 130,3 235,0 103,1 109,5 99,1 M16 x 121 3,5
730AT6326✖ 150 x 65 69,9 73,0 130,3 235,0 111,3 106,2 99,1 M16 x 121 4,0
730AT6330✖ 150 x 80 88,9 92,1 139,7 235,0 130,3 111,0 99,1 M16 x 121 4,7
730AT8020✖ 200 x 50 63,5 66,7 158,8 317,5 103,1 139,7 124,5 M20 x 121 5,5
730AT8026✖ 200 x 65 69,9 73,0 158,8 317,5 111,3 130,0 124,5 M20 x 121 5,7
730AT8030✖ 200 x 80 88,9 92,1 165,1 317,5 155,7 141,2 124,5 M20 x 121 6,1
✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised finish
† Proper hole preparation is required for effective sealing and performance. Check the pipe seal surface within 15.9mm ( 5⁄8") of the hole to
ensure it is free from conditions affecting proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact
area that might affect assembly, proper seating of the locating collar, or flow from the outlet. For crosses, ensure double outlet holes are
aligned on opposite sides of the pipe. The use of threaded products other than steel pipe, such as dry pendent sprinklers, may not be
compatible with the female threaded outlet on the Mechanical Tee. Always confirm compatibility by contacting Tyco Technical Services.
‡ Maximum pressures and end loads are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ
on other pipe materials and/or wall thickness. Contact Tyco Technical Services for details.
Threads are BSP. Some size outlets are available with NPT threads. Contact Tyco Technical Services for details.
For information on other alternative sizes, contact Tyco Technical Services
See page 9-32 for gasket information.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 10–29
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Grooved Piping Products


Figure 730
Mechanical Tees Grooved

Run Sizes DN50 thru DN200 (2" thru 8")

Branch Sizes DN32 thru DN100 outlets (1-1 ⁄4" thru 4")

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

Maximum Working
20,7 bar (300 psi)
Pressure

Grade “E” EPDM


-34°C to 110°C (-30°F to 230°F)
Gasket Temperature

Tech Data Sheet TFP1860

The GRINNELL 730 Mechanical Tees & Crosses come with threaded or grooved outlets and can be used for any tee connection
where a threaded or grooved outlet is needed. • It can be used in place of a tee, a cross connection, or a welded outlet where a
threaded or grooved outlet is needed. • The Mechanical Tee is ideal for use in retrofit or equipment hookup installations as it can be
positioned along the pipe at the proper location in the field, ensuring exact lineup of the branch outlet connection.

C
B

Issue 03, 04, 07


A
Cert No. 570, 669, 673
Hole
For detailed Listing and Approval
information contact
Dia.
Tyco Fire Protection Products. D

Nominal Size Hole Dia.† Dimensions - mm Bolt Approx.


Part
Run x Branch Min. Max. Size Weight
Number A B C D
DN mm mm mm kg
730AG2012✖ 50 x 32 44,5 47,6 70,6 124,0 84,3 40,4 M10 x 57 1,1
730AG2015✖ 50 x 40 44,5 47,6 66,5 124,0 84,3 40,4 M10 x 57 1,1
730AG2512✖ 65 x 32 50,8 54,0 76,2 133,4 90,4 46,0 M10 x 57 1,1
730AG2515✖ 65 x 40 50,8 54,0 78,0 133,4 91,2 46,0 M10 x 57 1,1
730MG2520✖ 65 x 50 50,8 54,0 81,0 133,4 101,6 46,0 M10 x 57 1,1
730MG2612✖ 65 x 32 50,8 54,0 77,7 142,7 90,4 47,5 M10 x 57 1,1
730MG2615✖ 65 x 40 50,8 54,0 79,5 142,7 90,4 47,5 M10 x 57 1,1
730MG2620✖ 65 x 50 50,8 54,0 82,6 142,7 101,6 47,5 M10 x 57 1,1
730MG3012✖ 80 x 32 44,5 47,6 84,8 155,7 84,3 56,1 M12 x 76 1,6
730MG3015✖ 80 x 40 50,8 54,0 85,9 155,7 90,4 56,1 M12 x 76 1,6
730MG3020✖ 80 x 50 63,5 66,7 88,9 155,7 103,9 56,1 M12 x 76 2,0
730AG4212✖ 100 x 32 44,5 47,6 99,6 181,1 84,3 70,6 M12 x 76 2,2
730AG4215✖ 100 x 40 50,8 54,0 101,6 181,1 90,4 70,6 M12 x 76 2,3
730MG4220✖ 100 x 50 63,5 66,7 101,6 181,1 103,1 70,6 M12 x 76 2,4
730MG4225✖ 100 x 65 69,9 73,0 101,6 181,1 111,3 70,6 M12 x 76 2,7
730MG4226✖ 100 x 65 69,9 73,0 101,6 181,1 111,3 70,6 M12 x 76 2,7
730MG4230✖ 100 x 80 88,9 92,1 104,9 181,1 130,3 70,6 M12 x 76 3,4
730MG5315✖ 125 x 40 50,8 54,0 117,6 206,5 90,4 85,6 M16 x 121 3,5
730MG5320✖ 125 x 50 63,5 66,7 117,6 206,5 103,1 85,6 M16 x 121 3,4
730MG5325✖ 125 x 65 69,9 73,0 120,7 206,5 111,3 85,6 M16 x 121 3,9
730MG5326✖ 125 x 65 69,9 73,0 120,7 206,5 111,3 85,6 M16 x 121 3,9
730MG5330✖ 125 x 80 88,9 92,1 127,0 206,5 130,3 85,6 M16 x 121 5,6

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

10–30
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Grooved Piping Products
Figure 730 - Mechanical Tees Grooved
C
B

A
Hole
Dia.
D

Nominal Size Hole Dia.† Dimensions - mm Bolt Approx.


Part
Run x Branch
Min. Max. Size Weight
Number A B C D
DN mm mm mm kg
730MG6212✖ 150 x 32 50,8 54,0 130,3 235,0 90,4 99,1 M16 x 121 3,5
730AG6215✖ 150 x 40 50,8 54,0 130,3 235,0 90,4 99,1 M16 x 121 3,4
730AG6220✖ 150 x 50 63,5 66,7 130,3 235,0 103,1 99,1 M16 x 121 3,6
730AG6225✖ 150 x 65 69,9 73,0 130,3 235,0 111,3 99,1 M16 x 121 4,0
730AG6226✖ 150 x 65 69,9 73,0 130,3 235,0 111,3 99,1 M16 x 121 4,0
730AG6230✖ 150 x 80 88,9 92,1 139,7 235,0 130,3 99,1 M16 x 121 4,6
730AG6242✖ 150 x 100 114,3 117,5 136,7 235,0 155,7 99,1 M16 x 121 5,3
730MG6312✖ 150 x 32 50,8 54,0 130,3 235,0 90,4 99,1 M16 x 121 3,5
730AG6315✖ 150 x 40 50,8 54,0 130,3 235,0 90,4 99,1 M16 x 121 3,4
730AG6320✖ 150 x 50 63,5 66,7 130,3 235,0 103,1 99,1 M16 x 121 3,6
730AG6325✖ 150 x 65 69,9 73,0 130,3 235,0 111,3 99,1 M16 x 121 4,0
730AG6326✖ 150 x 65 69,9 73,0 130,3 235,0 111,3 99,1 M16 x 121 4,0
730AG6330✖ 150 x 80 88,9 92,1 139,7 235,0 130,3 99,1 M16 x 121 4,6
730AG6342✖ 150 x 100 114,3 117,5 136,7 235,0 155,7 99,1 M16 x 121 5,3
730AG8020✖ 200 x 50 63,5 66,7 158,8 317,5 103,1 124,5 M20 x 121 5,5
730AG8025✖ 200 x 65 69,9 73,0 158,8 317,5 111,3 124,5 M20 x 121 5,6
730AG8026✖ 200 x 65 69,9 73,0 158,8 317,5 111,3 124,5 M20 x 121 5,6
730AG8030✖ 200 x 80 88,9 92,1 165,1 317,5 130,3 124,5 M20 x 121 6,0
730AG8042✖ 200 x 100 114,3 117,5 162,1 317,5 155,7 124,5 M20 x 121 6,7
✖ = 1 for red paint (RAL 3000) finish, 2 for hot dipped galvanised finish
†Proper hole preparation is required for effective sealing and performance. Check the pipe seal surface within 15.9mm (5⁄8") of the hole to
ensure it is free from conditions affecting proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact
area that might affect assembly, proper seating of the locating collar, or flow from the outlet. For crosses, ensure double outlet holes are
aligned on opposite sides of the pipe.
‡Maximum pressures and end loads are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on
other pipe materials and/or wall thickness. Contact Tyco Technical Services for details.
For information on other alternative sizes, contact Tyco Technical Services.
See page 9-32 for gasket information.

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 10–31
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Grooved Piping Products


Figure 730 & 522

Replacement Gaskets

Approvals UL, ULC Listed & FM, VdS, & LPCB Approved

Grade “E” EPDM


-34°C to 110°C (-30°F to 230°F)
Gasket Temperature

Tech Data Sheet TFP1895

The gasket provides a compression type seal, which is designed to conform to the exterior curve (OD) of the pipe. This design
is unique to the Figure 730 Mechanical Tee (threaded and grooved) and Figure 522 Sprinkler Outlet. • Note: When used in low
temperature applications, use a petroleum-free silicone based lubricant, otherwise no lubricant is required on Mechanical Tee and
Strap gaskets.

Figure 730 Gaskets Figure 522 Gaskets

Outlet Size Outlet Size

Run Size Run Size

EPDM Nitrile EPDM


Run Size Outlet Size Run Size Outlet Size
Grade E Grade T Grade E
mm mm mm mm
730-Style 730-Style 522-Style
50, 65, 80, 100 15, 20, 25 1EPDM730 1BUNA730 32 10 976-001
50, 80, 100 32 2EPDM730 2BUNA730 25, 32, 40 15, 20, 25 976-001
50 40 2EPDM730 2BUNA730 50 15, 20 976-001
65, 80, 100, 150 40 3EPDM730 3BUNA730 65 15, 20 976-001
65 32 3EPDM730 3BUNA730 25 15, 20, 25 976-290
150 32 3EPDM730 3BUNA730 50 25 976-304
65 50 3EPDM730 3BUNA730 65 25 976-304
80, 100, 125, 150, 200 50 4EPDM730 4BUNA730
100, 125 65 5EPDM730 5BUNA730
150, 200 65 6EPDM730 6BUNA730
100, 125 80 7EPDM730 7BUNA730
150, 200 80 8EPDM730 8BUNA730
150, 200 100 9EPDM730 9BUNA730

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

10–32
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Corrosion Solutions
Corrosion in fire sprinkler systems leads to plugging problems, diminished sprinkler performance, water leak
damage and reduced service life. The Model NG-1 nitrogen generator is at the heart of the Tyco corrosion
solutions portfolio.

Return on Investment (ROI) for Tyco Corrosion Solutions


- Greatly reduces corrosion - Minimizes risk of business
risks interruption due to leaks

- Extends the useful life of a


water-based fire sprinkler
system

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 11–1
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Corrosion Solutions
Model NG-1 100, NG-1 250, and NG-1 500
Wall-Mounted Nitrogen Generator
Air Compressor Integral

CE and FM Approved
Approvals
UL508A Listed Industrial Control Panel

NG-1 100 - 2555 L (675 Gal)


Total System
NG-1 250 - 3596 L (950 Gal)
Capacity
NG-1 100 - 7571 L (2000 Gal)

Nitrogen Membrane Capable of 98%+ Nitrogen Purity

Temperature Rating 5°C (40°F) to 40°C (105°F)

230 VAC/1 phase/50Hz


Power Supply
(120 VAC/1phase/60Hz)

Tech Data Sheet TFP1251

Mitigating Fire Sprinkler System Corrosion • Compatible with both new and existing fire sprinkler systems • Integral oil-less
compressor • Fill-and-purge breathing method allows vent to be installed on riser • No nitrogen tank or refrigerated dryers
required • Minimal footprint allowing for easy installation in riser room • Replacing oxygen in the system with nitrogen can stop the
corrosion process and extend the service life of a sprinkler system

Nitrogen Generators - Includes Generator Cabinet and Integral Compressor


Part Total System Capacity Dimensions (mm) Weight Approval & Listings
Model
Number Liter Gallon Width Height Depth (kg) FM CE
TNG0100E NG-1 100 2555 675 622 927 235 57 √ √
TNG0250E NG-1 250 3596 950 622 927 235 57 √ √
TNG0500E NG-1 500 7571 2000 724 927 292 79 √ √

Accessories
Description Model Part Number
Dry Air Vent TAV-D TAVD02

SMART Dry Air Vent - 230 VAC/50Hz TSV-D TSVD02E

Filter Replacement Kit – TNGFLTW

Optional Monitoring Equipment - Handheld Gas Analyzer THGA THGA01

Optional Monitoring Equipment - SMART Gas Analyzer TSGA TSGA01

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

11–2
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Corrosion Solutions
Model NG-1 1150, NG-1 1500, NG-1 2000, and NG-1 3000
Stand-Alone Nitrogen Generator
Air Compressor Separate

CE and FM Approved
Approvals
UL508A Listed Industrial Control Panel

NG-1 1150 - 24605 L (6500 Gal)


Total System NG-1 1500 - 41640 L (11000 Gal)
Capacity NG-1 2000 - 70030 L (18500 Gal)
NG-1 3000 - 85172 L (22500 Gal)

Nitrogen Membrane Capable of 98%+ Nitrogen Purity

Temperature Rating 5°C (40°F) to 40°C (105°F)

230 VAC/1 phase/50Hz


Power Supply
(120 VAC/1phase/60Hz)

Tech Data Sheet TFP1253

Mitigating Fire Sprinkler System Corrosion • Designed to support projects with larger system capacities • Compatible with both
new and existing fire sprinkler systems • Paired with oil-lubricated oil compressor • Fill-and-purge breathing method allows vent
to be installed on riser • No nitrogen tank or refrigerated dryers required • Designed on single skid for easy installation • Replacing
oxygen in the system with nitrogen can stop the corrosion process and extend the service life of a sprinkler system

Nitrogen Generators - Generator Cabinet and Compressor Sold Separately


Cabinet Dimensions (mm)
Part Total System Capacity Weight Approval & Listings
Model Without Bypass With Bypass
Number (kg)
Liter Gallon Width Height Depth Width Height Depth FM CE
TNG1150EG NG-1 1150 24605 6500 622 1334 216 826 1334 216 69 √ √
TNG1500EG NG-1 1500 41640 11000 622 1334 216 826 1334 216 69 √ √
TNG2000EG NG-1 2000 70030 18500 622 1930 318 813 1930 318 136 √ √
TNG3000EG NG-1 3000 85172 22500 622 1930 318 813 1930 318 136 √ √

Accessories
Description Model Part Number
Filter Replacement Kit – TNGFLTS
Dry Air Vent TAV-D TAVD02
SMART Dry Air Vent - 230 VAC/50Hz TSV-D TSVD02E
Optional Monitoring Equipment - Handheld Gas Analyzer THGA THGA01
Optional Monitoring Equipment - SMART Gas Analyzer TSGA TSGA01
Compressor - 230 VAC / Triple Phase / 50 Hz TNE502335S
Compressor - 400 VAC / Triple Phase / 50 Hz TNE504035S
For use with
Compressor - 440 VAC / Triple Phase / 50 Hz TNE504435S
NG-1 1150
Compressor - 500 VAC / Triple Phase / 50 Hz TNE505035S
Compressor - 550 VAC / Triple Phase / 50 Hz TNE505535S
Compressor - 230 VAC / Triple Phase / 50 Hz TNE752335S
Compressor - 400 VAC / Triple Phase / 50 Hz For use with TNE754035S
Compressor - 500 VAC / Triple Phase / 50 Hz NG-1 1500 or TNE755035S
Compressor - 575 VAC / Triple Phase / 50 Hz NG-1 2000 TNE755735S
Compressor - 690 VAC / Triple Phase / 50 Hz TNE756935S
Compressor - 230 VAC / Triple Phase / 50 Hz For use with TNE102335S
Compressor - 400 VAC / Triple Phase / 50 Hz NG-1 3000 TNE104035S

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 11–3
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Corrosion Solutions
Model TILD
In-Line Corrosion Detector
Sizes DN32 thru DN200 (1-1 ⁄4" thru 8")

Approvals UL Listed

Pipe Schedule Schedule 10 or 40

Temperature Rating -40°C (-40°F) to 49°C (120°F)

Service Pressure 12 bar (175 psi)

Tech Data Sheet TFP1261

Mitigating Fire Sprinkler System Corrosion • Corrosion Detector - Installed In-Line for Real-Time Monitoring • Monitor locally with
included Remote Test Station or remotely via the building monitoring system • Available in galvanized or black steel; schedule 10 or
40 • Roll-grooved ends for easy installation

Model TILD - In-Line Corrosion Detector


Approval & Listings
Pipe Size Pipe Material Pipe Schedule Part Number
UL
10 TILD1310B √
Black Steel
DN32 40 TILD1340B √
(1-1 ⁄4") 10 TILD1310G √
Galvanized
40 TILD1340G √
10 TILD1510B √
Black Steel
DN40 40 TILD1540B √
(1-1 ⁄ 2") 10 TILD1510G √
Galvanized
40 TILD1540G √
10 TILD2010B √
Black Steel
DN50 40 TILD2040B √
(2") 10 TILD2010G √
Galvanized
40 TILD2040G √
10 TILD2510B √
Black Steel
DN65 40 TILD2540B √
(2-1 ⁄ 2") 10 TILD2510G √
Galvanized
40 TILD2540G √
10 TILD3010B √
Black Steel
DN80 40 TILD3040B √
(3") 10 TILD3010G √
Galvanized
40 TILD3040G √
10 TILD4010B √
Black Steel
DN100 40 TILD4040B √
(4") 10 TILD4010G √
Galvanized
40 TILD4040G √
10 TILD6010B √
Black Steel
DN150 40 TILD6040B √
(6") 10 TILD6010G √
Galvanized
40 TILD6040G √
10 TILD8010B -
Black Steel
DN200 40 TILD8040B -
(8") 10 TILD8010G -
Galvanized
40 TILD8040G -

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

11–4
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Corrosion Solutions
Model TAV-D
Manual Air Vent - Dry Systems

System Connection 1" NPT Male

Temperature Rating 4.5°C (40°F) to 49°C (120°F)

Service Pressure Up to 12 bar (175 psi)

Tech Data Sheet TFP1262

Oxygen Removal Vent for Dry/Preaction Systems - Manual Shut-off • Designed for use with the NG-1 Nitrogen Generators • Can be
installed directly on system riser • Nitrogen gas sampling port for use with THGA or TSGA Gas Analyzers • Includes failsafe back-
pressure regulator • Automatic float shut-off in event of a system trip

Model TAV-D - Manual Air Vent - Dry Systems


Description Model Part Number
Dry Air Vent TAV-D TAVD02

Filter Replacement Kit TFLT TVDFLT2

Filter Replacement Kit for Legacy PN TAVD01 TFLT TVDFLT

IN-LINE FILTER RESTRICTED VENTING ORIFICE

MUFFLER

GAS SAMPLE PORT

FLOAT BACKPRESSURE REGULATOR


VALVE

CONNECTION TO
SPRINKLER SYSTEM
“Y” STRAINER
WITH BALL VALVE
ISOLATION
BALL VALVE
QUICK CONNECT

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 11–5
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Corrosion Solutions
Model TSV-D
SMART Air Vent - Dry Systems
System Connection 1" NPT Male

Temperature Rating 4.5°C (40°F) to 49°C (120°F)

Electrical Connection 230 VAC/50Hz (120 VAC/60Hz); <2 Amps

Service Pressure Up to 12 bar (175 psi)

Tech Data Sheet TFP1263

Oxygen Removal Vent for Dry/Preaction Systems - Electronic Shut-off • Designed for use with the NG-1 Nitrogen Generators • Can
be installed directly on system riser • Will automatically shut off after 14-day nitrogen fill-and-purge process • Includes failsafe
back-pressure regulator • Automatic float shut-off in event of a system trip

Model TSV-D - SMART Air Vent - Dry Systems


Description Model Part Number
230 VAC/ 50 Hz TSV-D TSVD02E

Filter Replacement Kit for Legacy PN TSVD01 TFLT TVDFLT

Replacement Filter Kit TFLT TVDFLT2

IN-LINE BACKPRESSURE SOLENOID


FILTER REGULATOR
RESTRICTED VENTING
ORIFICE
FLOAT
VALVE MUFFLER

GAS SAMPLING PORT

QUICK CONNECT

CONNECTION TO
SPRINKLER SYSTEM

“Y” STRAINER
WITH BALL VALVE
ISOLATION BALL VALVE

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

11–6
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Corrosion Solutions
Model TAV-W
Automatic Air Vent - Wet Systems
1
System Connection ⁄ 2" NPT Male

Approvals UL Listed and FM Approved

Temperature Rating 4.5°C (40°F) to 49°C (120°F)

Service Pressure Up to 12 bar (175 psi)

Tech Data Sheet TFP1264

Oxygen Removal Vent for Wet Systems • Remove trapped air from wet fire sprinkler systems • Redundant float valve design to
eliminate risk of leaks - no need to plumb to drain • High-visibility pressure gauge easily seen from floor to confirm functionality •
Can be upgraded for Wet Pipe Nitrogen Inerting

Model TAV-W - Automatic Air Vent - Wet Systems


Description Model Part Number
Wet Air Vent TAV-W TAVW01

GAS DISCHARGE
ORIFICE
PRIMARY AND SECONDARY
GAS VENT VALVES
QUICK 127 mm
CONNECT (5”)
1/2” ISOLATION
BALL VALVE

51 mm
(2”")

“Y” STRAINER WITH 1/2” CONNECTION


PRESSURE TO SPRINKLER
BALL VALVE GAUGE SYSTEM

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 11–7
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Corrosion Solutions
Model TAV-WN
Air Vent, Wet - Nitrogen
1
System Connection ⁄ 2" NPT Male

Approvals UL Listed and FM Approved

Temperature Rating 4.5°C (40°F) to 49°C (120°F)

Service Pressure Up to 12 bar (175 psi)

Tech Data Sheet TFP1265

Oxygen Removal Vent for Wet Systems - Wet Pipe Nitrogen Inerting • Remove trapped air from wet fire sprinkler systems •
Includes TNIP Nitrogen Inerting Port for Wet Pipe Nitrogen Inerting process • Redundant float valve design to eliminate risk of leaks
- no need to plumb to drain • High-visibility pressure gauge easily seen from floor to confirm functionality • Can be used with TRIS
Remote Inerting Station (sold separately) during WPNI process

Model TAV-WN - Air Vent - Wet - Nitrogen


Description Model Part Number
Wet - Nitrogen Air Vent TAV-WN TAVWN01

GAS SAMPLING PORT

PRIMARY AND SECONDARY


GAS VENT VALVES
140 mm
PRESSURE RELIEF VALVE (5.5”)
QUICK
CONNECT 1/2” ISOLATION
BALL VALVE

“Y” STRAINER WITH 89 mm


BALL VALVE (3.5”)
1/2” CONNECTION
TO SPRINKLER
PRESSURE GAUGE SYSTEM

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

11–8
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Corrosion Solutions
Model TNIP
Nitrogen Injection Port
1
⁄ 2" NPT Male (vent.)
System Connection
1" NPT Male (Port)

Temperature Rating 4.5°C (40°F) to 49°C (120°F)

Service Pressure Up to 12 bar (175 psi)

Tech Data Sheet TFP1265

Nitrogen Injection Port for use during Wet Pipe Nitrogen Inerting Process • For use during the Wet Pipe Nitrogen Inerting Process •
Installed on riser on the system side of the main control valve • Also available with TAV-WN Automatic Air Vent

Model TNIP - Nitrogen Injection Port


Description Model Part Number
Nitrogen Injection Port TNIP TNIP01

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 11–9
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Corrosion Solutions
Model TRIS
Remote Inerting Station

Temperature Rating 4.5°C (40°F) to 49°C (120°F)

Service Pressure Up to 12 bar (175 psi)

Tech Data Sheet TFP1265

Control Station for Remote Monitoring of TAV-WN Air Vent • For use during the Wet Pipe Nitrogen Inerting Process • Provides
remote monitoring and control options for the TAV-WN Automatic Air Vent

Model TRIS - Remote Inerting Station


Description Model Part Number
Remote Inerting Station TRIS TRIS01

1 2 3

3
1

TAV-WN/TRIS Connections
Number Description
1 Exhaust Gas Connection
2 Y-Strainer “Purge” Connection
3 Gas Sampling Port Connection

4 Nitrogen Gas/Water Exhaust Connection

NOTE: Y-Strainer “Purge” Connection will be exposed to system


operating pressure TAV-WN/TRIS Connections

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

11–10
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Corrosion Solutions
Model THGA
Handheld Gas Analyzer
Sensor Type Galvanic Cell with temperature compensation

Operating Pressure
Atmospheric pressure to 0,2 bar (3 psig)
Rating

Operating
15°C to 40°C (59°F to 104°F)
Temperature

Measured Range 0.0% to 99.9% nitrogen

Response Time <15 seconds for 90% step change

Tech Data Sheet TFP1267

Handheld Gas Analyzer for use with Dry or Wet Pipe Nitrogen Inerting • Displays nitrogen purity of the gas stream being sampled
• Lithium battery powered • One-touch calibration • Includes tubing and quick connect fitting compatible with TYCO Nitrogen
products • Also available as part of TGSK Gas Sampling Kit

Model THGA - Handheld Gas Analyzer


Description Model Part Number
Handheld Gas Analyzer THGA THGA01

SAMPLING HOSE

CALIBRATION
BUTTON

QUICK DISCONNECT POWER ON BUTTON DISPLAY

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 11–11
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Corrosion Solutions
Model TGSP
Gas Sampling Port

Material All industrial brass components

Tech Data Sheet TFP1267

Gas Sampling Port for Dry Pipe Nitrogen Inerting Monitoring • For use with THGA Handheld Gas Analyzer • Equipped with 1 ⁄ 2"
isolation valve • 1 ⁄4" quick connect socket • Also available as part of TGSK Gas Sampling Kit

Model TGSP - Gas Sampling Port


Description Model Part Number
Gas Sampling Port TGSP TGSP01

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

11–12
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Corrosion Solutions
Model TGSK
Gas Sampling Kit
Sensor Type Galvanic Cell with temperature compensation

Operating Pressure
Atmospheric pressure to 0,2 bar (3 psig)
Rating

Operating
15°C to 40°C (59°F to 104°F)
Temperature

Measured Range 0.0% to 99.9% nitrogen

Response Time <15 seconds for 90% step change

Tech Data Sheet TFP1267

Gas Sampling Components to monitor Dry Pipe Nitrogen Inerting • Monitor the nitrogen concentration in a sprinkler system
equipped with a TYCO Nitrogen Generator • Includes the THGA Handheld Gas Analyzer and TGSP Gas Sampling Port

Model TGSK - Gas Sampling Kit


Description Model Part Number
Gas Sampling Kit TGSK TGSKP01

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 11–13
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Corrosion Solutions
Model TNIM
Nitrogen Inerting Manifold

Hose Size 9,5mm x 7,6m (3 ⁄ 8" x 25 foot)

Hose Pressure
Up to 21 bar (300 psi)
Rating

Nitrogen/Air Inlet: 1 ⁄ 2" NPT Female


Connection Outlet: 1 ⁄4" Quick Disconnect

Tech Data Sheet TFP1268

Inerting Manifold for the Wet Pipe Nitrogen Inerting Process • For use with TNIP Nitrogen Inerting Port • Includes gas sampling
port to verify nitrogen concentration at the inlet supply • Single pressure regulator to regulate nitrogen delivery pressure to the
discharge connection

Model TNIM - Nitrogen Inerting Manifold


Description Model Part Number
Nitrogen Inerting Manifold TNIM TNIM01

NITROGEN INLET
PRESSURE GAUGE
NITROGEN GAS NITROGEN OUTLET
SAMPLING PORT PRESSURE GAUGE

NITROGEN OUTLET FLEXIBLE HOSE


QUICK CONNECT
NITROGEN
SOURCE INLET

NITROGEN OUTLET
BALL VALVE
NITROGEN OUTLET
PRESSURE REGULATOR

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

11–14
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Corrosion Solutions
Model TNIC
Nitrogen Interface Controller

230 VAC/Single Phase/50 Hz - Dedicated Circuit


Power Supply
(120 VAC/Single Phase/60 Hz -Dedicated Circuit)

Nitrogen/Air Inlet: 1 ⁄ 2" NPT Female


Connection Outlet: 1 ⁄ 2" NPT Female

Tech Data Sheet TFP1269

Interface Controller for Dry Pipe Inerting Process • Use with house/plant nitrogen source for controlling oxygen corrosion in dry/
preaction systems • Can be used with TYCO NG-1 Nitrogen Generators to control multiple systems operating at different pressures

Model TNIC - Nitrogen Interface Controller


Description Model Part Number
Nitrogen Interface Controller TNIC TNIC01

MOUNTING SLOT MOUNTING SLOT

CABINET

ON/OFF POWER
SWITCH

NITROGEN SUPPLY
NITROGEN SUPPLY OUTLET
INLET

MOUNTING SLOT MOUNTING SLOT

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

www.tyco-fire.com 11–15
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Corrosion Solutions
Model TSGA
SMART Gas Analyzer
Sensor Type Zirconium Dioxide

120 VAC, 60 Hz/0.5 A


Electrical
230 VAC, 50 Hz/0.5 A
Connections
24 VDC/2 A

Temperature Range 5°C to 40°C (40°F to 105°F)

Output Display %O2 or %N2

0 VDC to 5 VDC linear output,


Signal Output
4 mA to 20 mA linear output

Percentage of O2
1%, 3%, or 5%
Contact Closure Level

Tech Data Sheet TFP1270

Electronic Gas Analyzer for use with Dry or Preaction Systems • Continuous real-time monitoring of Nitrogen/Oxygen concentration
levels • Can be monitored by building information management or fire alarm systems • Pair with either TAV-D Manual Air Vent or
TSV-D Smart Air Vent

Model TSGA - SMART Gas Analyzer


Description Model Part Number
SMART Gas Analyzer TSGA TSGA01

Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.

11–16
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Index

Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Keyword or Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page Keyword or Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page

557. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–49 Bevelling Tool. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–11


807. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–47 BFV-300 - Electric Actuator. . . . . . . . . . . . . . . . . . . . . . 4–11 to 4–13
“Y” Flanged Strainer . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–44 to 4–45 BFV-300 - Hydraulic Actuator, TruTorq . . . . . . . . . . . . . . 4–9 to 4–10
11-1 ⁄4° Elbows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–20 BFV-300 Grooved End Butterfly Valve. . . . . . . . . . . . . . . . 4–2 to 4–5
22-1 ⁄ 2° Elbows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–19 BFV-300 Wafer Style Butterfly Valve. . . . . . . . . . . . . . . . . 4–6 to 4–8
4410-RC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–61 BIGGY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–26
45° Elbows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–14 Branch Line Tester. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–59
74A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–48 Branch Outlets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8–8 to 8–8
760P. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–45 Branch Outlets Grooved. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8–10
90° Elbows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–13 Branch Outlets Non-Chamfered. . . . . . . . . . . . . . . . . . . . . . . . . . 8–9
90° Fire Department Connections. . . . . . . . . . . . . . . . . . . . . . . 3–61 Branch Outlets Threaded. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8–8
A201 - Angle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–68 C-Let Branch Outlets Non-Chamfered. . . . . . . . . . . . . . . . . . . . . 8–9
A202 - Angle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–69 CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–131
A203 - Globe. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–68 CC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–132
A204 - Globe. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–69 CC3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–133
ACC-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–25 CHEC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–39
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–4 to 11–16 Combustible Concealed Space Sprinklers™, Upright . . 1–131 to 1–133
AD-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–42 Compressors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–32 to 3–34
AD-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–43 Concealed Horizontal Extended Coverage Sidewall. . . . . . . . . . . 1–39
ADPS-300-1B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–17 Concealed Horizontal Sidewall. . . . . . . . . . . . . . . . . . . . . . 1–25, 1–87
Air Feeding Devices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–30 Concealed Pendent . . . . . . . . . . . . 1–17 to 1–18, 1–41 to 1–42, 1–112
Air Maintenance Device. . . . . . . . . . . . . . . . . . . . . . . . . 3–27 to 3–28 Concealed Standard Coverage Pendent Sprinklers. . . . . . . . . . . . 1–26
Air Release Valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–73 Concentric Reducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–23
Air Vent, Wet - Nitrogen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–8 Contact Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Back Cover
Alarm Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–2 Control Unit Sprinkler Pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–20
Alternate Valve Assemblies, Model LPC Trim. . . . . . . . . . . . . . . 3–24 Conventional (Old Style). . . . . . . . . . . . . . . . . . . . . . . . 1–139 to 1–145
Altitude Valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–83 Conventional Sprinklers, Special Response . . . . . . . . . . . . . . . . 1–137
AMD-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–27 Cooling Tower Nozzle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–186
AMD-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–28 Corrosion Solutions. . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–2 to 11–16
AMD-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–29 Couplings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–2 to 10–12
ANSI Flanged Cross Strainer. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–46 Cover Plate for Concealed Sprinklers. . . . . . . . . . . . . . . . . . . . . 1–88
Anti-Vortes Plates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–75 CPVC Back-to-Back Sprinkler Head Tee or Cross. . . . . . 6–23 to 6–24
AP (Attic Plus) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–120 CPVC Bush Reducing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–13
Aquamist FOG System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–3 CPVC Caulk & Walk®. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–38
Aquamist Sonic System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–4 CPVC Cement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–36
AQUAMIST Strainer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–47 CPVC Coupling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–9 to 6–10
Aquamist ULF System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–2 CPVC Coupling Adaptor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–14
Attic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–120 to 1–121 CPVC Cross . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–7 to 6–8
Automatic Air Vent - Wet Systems . . . . . . . . . . . . . . . . . . . . . . . 11–7 CPVC Dauber. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–36
Automatic Drain Valve. . . . . . . . . . . . . . . . . . . . . . . . . . 3–42 to 3–43 CPVC Deburring Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–37
Automatic Protectospray Directional Spray Nozzle . . . . . . . . . 1–180 CPVC Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–3 to 6–5
Automatic Supervisory Air Supply. . . . . . . . . . . . . . . . . . . . . . . 3–31 CPVC End Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–11
AV-1-300. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–2 to 3–3 CPVC Fittings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–3 to 6–33
AV-1-300 Supervised Wet System Valve Assemblies CPVC Flow Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–35
with CE/FM Trim. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–6 CPVC Hangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–39
AV-1-300 Wet System Valve Assemblies with CE/FM Trim . . . . . 3–5 CPVC Pipe & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–2 to 6–39
AV-1-300 Wet System Valve Assemblies with CE/VdS Trim. . . . . 3–7 CPVC Pipe Cutter Tool. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–36
AV-1-300 Wet System Valve Assemblies with FM Trim. . . . . . . . 3–4 CPVC Rapid Seal Adapter (RSA). . . . . . . . . . . . . . . . . . . 6–27 to 6–33
B-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–187 CPVC Raven Studio Sprinkler Adapters . . . . . . . . . . . . . 6–25 to 6–26
Backflow Preventers . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–76 to 4–77 CPVC Riser. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–34
Bar Fixing Clamps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8–4 CPVC Sprinkler Head Adaptor . . . . . . . . . . . . . . . . . . . . 6–17 to 6–22
Battery Pressing Tool Mini 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–14 CPVC Sprinkler Pipe. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–2
Battery Pressing Tool UP 75. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–13 CPVC Tees. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–6, 6–12
BB (Back-to-Back). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–120 CPVC Test Plugs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–37
Bending Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–12 CPVC Thread Sealant. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–38
12-2
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Keyword or Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page Keyword or Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page

CPVC Threaded Adaptor. . . . . . . . . . . . . . . . . . . . . . . . . 6–15 to 6–16 EC-11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–29


Cross Wall Indicator Post. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–28 EC-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–29 to 1–30
CUSP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–20 EC-25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–28, 1–46
CV-1F Grooved Check Valve. . . . . . . . . . . . . . . . . . . . . . 4–33 to 4–34 EC-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–33 to 1–34
CV-1FR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–9 EC-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–31
CV-1FR - Grooved-End Riser Check Valve. . . . . . . . . . . 4–35 to 4–36 EC-8C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–32
CWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–129 Electric Actuator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–11
D3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–177 Electric Bells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–38
D3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–178 Electric Pressing Tool UP 75 EL. . . . . . . . . . . . . . . . . . . . . . . . . . . 7–13
D4a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–183 Electric/Electric or Electric/Pneumatic Actuation. . . . . . . . . . . . 3–55
Deluge & Preaction Systems . . . . . . . . . . . . . . . . . . . . . 3–36 to 3–61 Electromagnetic Flow Meters. . . . . . . . . . . . . . . . . . . . . . . . . . . 5–28
Deluge Systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–44 to 3–49 Electronic Accelerator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–26
Deluge Systems, Dry Pilot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–46 ELO SW-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–37
Deluge Systems, Electric Actuation. . . . . . . . . . . . . . . . . . . . . . 3–47 ELO SW-24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–37
Deluge Systems, Remote Resetting. . . . . . . . . . . . . . . . . . . . . . 3–48 ELO-231. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–61 to 1–62
Deluge Systems, Remote Resetting, Pressure Reducing. . . . . . . 3–49 ELO-231 FRB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–60
Deluge Systems, Wet Pilot. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–45 ELO-231B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–58 to 1–59
Deluge Valve, External Resetting. . . . . . . . . . . . . . . . . . . . . . . . 3–36 ELOC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–40
Directional Spray Nozzle . . . . . . . . . . . . . . . . . 1–179, 1–183 to 1–185 EMERAUDE CS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–57
Domed Plate Concealed Pendent. . . . . . . . . . . . . . . . . . . . . . . . 1–86 End Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–16
Double Interlock Preaction System, Escutcheon Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–161 to 1–164
Electric/Electric Actuation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–56 ESFR-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–54
Double Interlock Preaction System, ESFR-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–49 to 1–53
Electric/Pneumatic Actuation. . . . . . . . . . . . . . . . . . . . . . . . . . . 3–57
ESFR-22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–48
Double Interlock Preaction System, Type A. . . . . . . . . . . . . . . . 3–58
ESFR-25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–47
Double Interlock Preaction Systems. . . . . . . . . . . . . . . . . . . . . . 3–55
ESFR-34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–45
DP-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–38
Explosion Proof Flow Switch, Vane Type. . . . . . . . . . . . . . . . . . . 5–9
DPV-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–17
Explosion Proof Pressure Switch. . . . . . . . . . . . . . . . . . . . . . . . . 5–16
Drencher Nozzle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–174
Explosion Proof Supervisory Switch. . . . . . . . . . . . . . . . 5–23 to 5–24
Drop Nipples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8–6 to 8–7
Exposure Protection Nozzle. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–176
Drop Nipples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8–7
Extended Coverage Concealed Pendent. . . . . . . . . . . . . . . . . . . 1–114
Dry Pilot Actuator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–38
Extended Coverage Horizontal Sidewall. . . . . . . . . . . . . 1–100, 1–116
Dry Pipe Sprinkler Systems . . . . . . . . . . . . . . . . . . . . . . 3–17 to 3–34
Extended Coverage Pendent . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–110
Dry Pipe Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–17
Extended Coverage Sprinklers. . . . . . . . . . . . . . . . . . . . 1–28 to 1–43
Dry Pipe Valve Accelerator . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–25
Extra Large Orifice Concealed Pendent . . . . . . . . . . . . . . . . . . . 1–40
Dry Sprinkler Boot. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–118
F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–46
Dry Sprinklers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–96 to 1–118
F822 thru F834 Mulsifyre® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–184
Dry System Valve Assemblies DPV-1 with CE/FM Trim. . 3–22 to 3–23
F822S thru F834S Mulsifyre® . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–185
Dry System Valve Assemblies DPV-1 with CE/VdS Trim. 3–20 to 3–21
Fastflex Flexible Sprinkler Hose Assembly. . . . . . . . . . . . . . . . . . 8–2
Dry System Valve Assemblies DPV-1 with FM Trim. . . . 3–18 to 3–19
Fastflex Sprinkler Accessories. . . . . . . . . . . . . . . . . . . . . . 8–3 to 8–5
Dry Type Recessed Horizontal Sidewall. . . . . . . . . . . . . . . . . . . 1–90
Feeding Device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–34
Dry Type Recessed Pendent. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–89
Feeding Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–33
Dry-Type Pendent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–53
Feeding Tank Hot Dip Galvanized. . . . . . . . . . . . . . . . . . . . . . . . 5–33
DS-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–96 to 1–101
Female Press Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–3
DS-1 Dry Sprinkler Guards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–118
Female Press Elbow 90°. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–8
DS-1 Stainless Steel. . . . . . . . . . . . . . . . . . . . . . . . . . . 1–102 to 1–105
Female Press Sprinkler Tee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–9
DS-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–108 to 1–111
FF4-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–15
DS-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–116 to 1–117
Fig. I88. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–25
DS-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–106 to 1–107
Figure 211 / 311 11-1 ⁄4° Elbows . . . . . . . . . . . . . . . . . . . . . . . . . 10–20
DS-C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–112 to 1–113
Figure 212 / 312 22-1 ⁄ 2° Elbows. . . . . . . . . . . . . . . . . . . . . . . . . 10–19
DS-ECC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–114 to 1–115
Figure 221 / 321 Reducing Tees. . . . . . . . . . . . . . . . . . 10–21 to 10–22
DSB-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–118
Figure 222 Hydrant Tee. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–26
DV-5A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–36
Figure 250 / 350 Concentric Reducers . . . . . . . . . . . . 10–23 to 10–24
DV-5A Deluge Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–37
Figure 260 End Caps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–16
EA-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–180
Figure 322 Reducing Tees. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–25
www.tyco-fire.com 12-3
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Keyword or Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page Keyword or Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page

Figure 343 & 344 Flange Adapters. . . . . . . . . . . . . . . . . . . . . . 10–12 Gauge. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–36


Figure 501 45° Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–14 General Purpose Valves. . . . . . . . . . . . . . . . . . . . . . . . . . 4–2 to 4–84
Figure 510 90° Elbows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–13 Grooved Check Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–33
Figure 510S Short Pattern 90° Elbows. . . . . . . . . . . . . . . . . . . . 10–17 Grooved End Butterfly Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–2
Figure 519 Tees . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–15 Grooved Flexible Coupling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–3
Figure 519S Short Pattern Tees . . . . . . . . . . . . . . . . . . . . . . . . 10–18 Grooved Piping Products. . . . . . . . . . . . . . . . . . . . . . . 10–2 to 10–32
Figure 522 G-FIRE Threaded Sprinkler Outlet. . . . . . . . . . . . . . 10–27 Grooved-End Riser Check Valve. . . . . . . . . . . . . . . . . . . . . . . . . 4–35
Figure 577 Rigid Coupling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–2 Handheld Gas Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–11
Figure 577, 579, 705, 707 Replacement Gaskets . . . . . . . . . . . . . 10–6 Hangers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–61
Figure 705 Flexible Coupling. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–3 High Pressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–3
Figure 707 Flexible Coupling. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–4 High Temperature, Upright & Pendent. . . . . . . . . . . . . . . . . . . . 1–134
Figure 71 ANSI Flange. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–9 HIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–120
Figure 71 Flange Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–8 Horizontal Sidewall . . . . . . . . . . . . . . . . . . . 1–21, 1–24, 1–37 to 1–38
Figure 71 Replacement Gaskets. . . . . . . . . . . . . . . . . . . . . . . . . 10–11 Horizontal Sidewall & Recessed Horizontal
Figure 716 Flexible Reducing Coupling. . . . . . . . . . . . . . . . . . . . 10–5 Sidewall. . . . . . . . . . . . . . . . . . . . . . . . . . 1–34 to 1–35, 1–83 to 1–84

Figure 716 Replacement Gaskets . . . . . . . . . . . . . . . . . . . . . . . . 10–7 Horizontal Sidewall, and Extended Coverage Horizontal
Sidewall. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–104
Figure 730 & 522 Replacement Gaskets. . . . . . . . . . . . . . . . . . 10–32
Horizontal Spray Nozzle, Open. . . . . . . . . . . . . . . . . . . 1–181 to 1–182
Figure 730 Mechanical Tees BSP Threads. . . . . . . . . .10–28 to 10–29
Horizontal, Recessed Horizontal Sidewall & Vertical
Figure 730 Mechanical Tees Grooved. . . . . . . . . . . . . 10–30 to 10–31 Sidewall. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–7, 1–15
Fire Department Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 3–61 Hose Gate Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–54 to 4–55
Fittings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–13 to 10–32 Hose Rack Assemblies. . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–5 to 9–6
Fixed Reel Hose Reels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–3 Hose Reels & Cabinets. . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–2 to 9–6
Fixed Temperature Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–150 Hoses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–7 to 9–8
Flange Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–8 Hoses and Hose Reels . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–2 to 9–8
Flange Adapter Washers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–10 HV ”High Velocity”. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–179
Flange Adapters (PN10/PN16 BS 4504). . . . . . . . . . . . . . . . . . . 10–12 Hydrant Tee. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–26
Flange Check Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–41 to 4–43 Hydrants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–56 to 4–57
Flanged Pressure Relief Valve . . . . . . . . . . . . . . . . . . . . . . . . . . 4–70 Hydraulic Actuator, TruTorq. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–9
Flat Plate Concealed Horizontal Extended Coverage Sidewall . . 1–43 ILLUSION™. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–26
Flat Plate Concealed Pendent . . . . . . . . . . . . . . . . . . . . . . . . . . 1–85 In-Line Corrosion Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–4
Flat Spray, Upright & Pendent . . . . . . . . . . . . . . . . . . . . . . . . . . 1–135 INFLUX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–30
Flexible Coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–4 Installation Cup, Plug, & Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–16
Flexible Hose. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8–2 to 8–5 Institutional Horizontal Sidewall Sprinklers . . . . . . . . . . . . . . . . 1–128
Flexible Reducing Coupling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–5 Institutional Pendent & Horizontal Sidewall. . . . . . . . . . . . . . . . 1–124
Flexible Sprinkler Hose Assembly. . . . . . . . . . . . . . . . . . . . . . . . . 8–2 Institutional Pendent Sprinklers. . . . . . . . . . . . . . . . . . . . . . . . . 1–127
Float Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–34 Internal Bending Spring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–12
Float Switch for Level Regulations and Pump Control . . . . . . . . 5–34 Issue A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–176
Float Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–79 to 4–81 Issue B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–176
Flow Meter Butt Weld, Grooved Ends. . . . . . . . . . . . . . . . . . . . . 5–27 Issue D Quartzoid®. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–134
Flow Meters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–27 to 5–30 K17-231 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–57
Flow Switch, Low Flow Rate Vane Type. . . . . . . . . . . . . . . . . . . . 5–5 K3-10 - Altitude Valves. . . . . . . . . . . . . . . . . . . . . . . . . 4–83 to 4–84
Flow Switch, Vane Type. . . . . . . . . . . . . . . . . . . . . . . 5–4, 5–6 to 5–8 LD "Large Drop". . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–63
Flow Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–3 to 5–10 LE020. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–30
Flush Pendent Quick Response. . . . . . . . . . . . . . . . . . . . . . . . . . 1–126 LFII. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–80 to 1–90
Foot Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–74 LFII NFPA 13 Optimised Sprinklers. . . . . . . . . . . . . . . . . 1–91 to 1–93
For Releasing Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–39 Longneck Reduced Ends. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8–6
FSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–126 M & F Drop Nipples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8–7
FST-A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–31 MAGFLO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–28
FST-B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–32 Male Press Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–3
FTR-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–150 Male/Female Press 90° Elbow . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–8
FV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–75 Male/Female Press Sprinkler Tee. . . . . . . . . . . . . . . . . . . . . . . . . 7–9
G-FIRE Threaded Sprinkler Outlet . . . . . . . . . . . . . . . . . . . . . . 10–27 Manual Air Vent - Dry Systems . . . . . . . . . . . . . . . . . . . . . . . . . . 11–5
G5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–118 Manual Control Station. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–41
Gas Sampling Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–13 MAXANTKIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–37
Gas Sampling Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–12
12-4
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Keyword or Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page Keyword or Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page

MC-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–41 Model Reto Stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–41


Measuring and Electrical Devices . . . . . . . . . . . . . . . . . . 5–2 to 5–38 Model SV1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–79
Mechanical Tees BSP Threads . . . . . . . . . . . . . . . . . . . . . . . . 10–28 Model SV642 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–80
Mechanical Tees Grooved . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–30 Model TAV-D Manual Air Vent - Dry Systems . . . . . . . . . . . . . . . 11–5
Medium Velocity Nozzle . . . . . . . . . . . . . . . . . . . . . . . . 1–169, 1–171 Model TAV-W Automatic Air Vent - Wet Systems. . . . . . . . . . . . 11–7
Minimum Radius Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8–5 Model TAV-WN Air Vent, Wet - Nitrogen. . . . . . . . . . . . . . . . . . 11–8
MJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–159 Model TGSK Gas Sampling Kit . . . . . . . . . . . . . . . . . . . . . . . . . . 11–13
MJCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–158 Model TGSP Gas Sampling Port. . . . . . . . . . . . . . . . . . . . . . . . . 11–12
MJCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–157 Model THGA Handheld Gas Analyzer. . . . . . . . . . . . . . . . . . . . . 11–11
MLC-S Universal Casting Cup . . . . . . . . . . . . . . . . . . . . 7–15 to 7–16 Model TILD In-Line Corrosion Detector. . . . . . . . . . . . . . . . . . . 11–4
MLC-S Press Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–3 to 7–10 Model TJCV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–37
MLC-S Sprinkler Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–2 Model TJP Cross Wall Indicator Post . . . . . . . . . . . . . . . 4–28 to 4–29
MLC-S Sprinkler Pipe and Fittings . . . . . . . . . . . . . . . . . 7–2 to 7–16 Model TJP Resilient-Seated Gate Valves . . . . . . . . . . . . 4–22 to 4–25
MLC-S Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–11 to 7–16 Model TJP Vertical Indicator Post. . . . . . . . . . . . . . . . . . 4–26 to 4–27
Model 1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–58 Model TJR Resilient-Seated Gate Valves . . . . . . . . . . . . 4–18 to 4–21
Model 109 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–78 Model TJST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–44
Model 126S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–32 Model TNIC Nitrogen Interface Controller . . . . . . . . . . . . . . . . . 11–15
Model 15A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–73 Model TNIM Nitrogen Inerting Manifold. . . . . . . . . . . . . . . . . . . 11–14
Model 1610 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–31 Model TNIP Nitrogen Injection Port. . . . . . . . . . . . . . . . . . . . . . . 11–9
Model 24 & Model 302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–74 Model TRIS Remote Inerting Station . . . . . . . . . . . . . . . . . . . . . 11–10
Model 4908 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–30 Model TSGA SMART Gas Analyzer. . . . . . . . . . . . . . . . . . . . . . . 11–16
Model 55L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–67 Model TSV-D SMART Air Vent - Dry Systems. . . . . . . . . . . . . . 11–6
Model 601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–32 Model WSG-2 Sprinkler Guard with Shield. . . . . . . . . . . . . . . . . . 1–75
Model 62S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–42 Monitor Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–25 to 5–26
Model 7000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–66 Monitor Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–25 to 5–26
Model 70B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–55 MONOSTAB A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–70
Model 85 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–40 Multi Jet Controls, Single Inlet, Double Outlet. . . . . . . . . . . . . . 1–158
Model 8800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–38 Multi Jet Controls, Single Inlet, Single Outlet. . . . . . . . . . 1–157, 1–159
Model A-373 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–54 MV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–169 to 1–170
Model A201 & A203 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–68 MV-R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–173
Model A202 & A204 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–69 MV-T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–172
Model A59 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–59 Nipples. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8–5
Model A61 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–60 Nitrogen Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–2 to 11–3
Model AB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–32 Nitrogen Inerting Manifold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–14
Model BAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–76 Nitrogen Injection Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–9
Model BH-19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–63 Nitrogen Interface Controller. . . . . . . . . . . . . . . . . . . . . . . . . . . 11–15
Model BW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–50 Nitrogen Maintenance Device . . . . . . . . . . . . . . . . . . . . . . . . . . 3–29
Model C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–39 Non Rising Stem. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–14, 4–22
Model CCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–33 Nozzle & Nozzle Accessories. . . . . . . . . . . . . . . . . . . . 1–169 to 1–187
Removed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–34 OSYS-U-EX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–24
Model EA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–77 OSYSU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–22
Model EG-25 Sprinkler Guard . . . . . . . . . . . . . . . . . . . . . . . . . . 1–76 Other Pump Equipment . . . . . . . . . . . . . . . . . . . . . . . . . 4–73 to 4–84
Model G1 & G4 Sprinkler Guards . . . . . . . . . . . . . . . . . . . . . . . . 1–74 Outside Screw and Yoke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–18
Model G1/S1 & G4/S3 Guards with Shields . . . . . . . . . . . . . . . . . 1–74 PBA-AC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–38
Model G16AC812 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–31 PCVS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–21
Model G2 Sprinkler Guard, Model WS-2 Shield . . . . . . . . . . . . . . 1–75 Pendent. . . . . . . . . . . . . . . . 1–45 to 1–52, 1–54, 1–102, 1–108, 1–151
Model GUMC/GUWSU Sprinkler Guard . . . . . . . . . . . . . . . . . . . 1–77 Pendent & Horizontal Sidewall Sprinklers . . . . . . . . . . . . . . . . . 1–122
Model Infinity 05-47 Series Resilent Gate Valves . . . . . 4–14 to 4–17 Pendent & Recessed Pendent. . . . . . . . . . . . 1–31 to 1–33, 1–80, 1–82
Model N5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–43 Pendent & Upright, Intermediate Level . . . . . . . . . . . . . 1–64 to 1–72
Model NG-1 100, NG-1 250, and NG-1 500 Pendent, Recessed Pendent & Domed Concealed . . . . . . . . . . . 1–91
Wall-Mounted Nitrogen Generator . . . . . . . . . . . . . . . . . . . . . . .11–2 Pendent, Standard and Quick Response. . . . . . . . . . . . . . . . . . . 1–106
Model NG-1 1150, NG-1 1500, NG-1 2000, and NG-1 3000 Permabond Pipe Thread Sealant . . . . . . . . . . . . . . . . . . . . . . . . . 8–11
Stand-Alone Nitrogen Generator. . . . . . . . . . . . . . . . . . . . . . . . . 11–3
Pipe Cuttings Tool 25-63 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–11
Model RAF13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–81
Pipe Hangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–61
Model RAF13 - Float Valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–82

www.tyco-fire.com 12-5
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Fire Suppression General Products Catalogue

Keyword or Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page Keyword or Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page


Pipe Thread Sealant. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8–11 RM-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–11
PIVS-U-EX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–23 RM-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–12
Preaction, Type B Valves EN12845 Compliance . . . . . . . . . . . . . 3–59 RSV-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–10
Press 45° Elbow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–5 RT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–18
Press Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–10 RV-1A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–64
Press Coupling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–7 RV-1A - Flange Ends . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–65
Press Elbow 90°. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–4 RV-1A - Grooved Ends. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–64
Press Female 90° Elbow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–5 Saphir. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–56
Press Male 90° Elbow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–4 Saxon Hoses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–8
Press Reducer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–7 SD (Single Directional). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–120
Press Tee. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–6 Sealed MV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–171
Press Tee Reducer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–6 Self Testing Flow Switches and System Monitoring. . . . . . . . . . . 5–2
Pressing Jaw MLC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–14 Series 1054 Hose Rack Assemblies . . . . . . . . . . . . . . . . . . . . . . . 9–6
Pressing Jaw MLC Mini KSPO. . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–15 Series 2500 Hose Rack Assemblies. . . . . . . . . . . . . . . . . . . . . . . 9–5
Pressure Reading Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . 5–37 Short Pattern 90° Elbows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–17
Pressure Reducing Valve Pilot Operated . . . . . . . . . . . . . . . . . . 4–71 Short Pattern Tees. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–18
Pressure Relief Trim. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–8 Shut-Off Valve, Angle Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–32
Pressure Relief Valve Pilot-Operated. . . . . . . . . . . . . . . . . . . . . 4–64 Shut-Off Valve, Ball Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–31
Pressure Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–11 to 5–20 Shut-Off Valve, Ball Valve Stainless Steel Type 316. . . . . . . . . . 4–32
Protective Cap Utility Tool for Concealed Sprinklers . . . . . . . . . 1–88 Shut-Off Valve, Road Box Adjustable. . . . . . . . . . . . . . . . . . . . . 4–30
Protectospray Directional Spray Nozzle. . . . . . . . . . . . 1–177 to 1–178 Sight Flow Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–63
Proving Pipes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–35 Single Interlock Preaction System, Dry Pilot . . . . . . . . . . . . . . . 3–53
PRV-1 - Angle Style. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–72 Single Interlock Preaction System, Electric Actuation. . . . . . . . 3–54
PRV-1A - Groove Ends. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–71 Single Interlock Preaction System, Wet Pilot. . . . . . . . . . . . . . . 3–52
PS10-1 or PS10-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–11 Single Interlock Preaction Systems . . . . . . . . . . . . . . . . . . . . . . 3–51
PS10-EX or PS40-EX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–16 SMART Air Vent - Dry Systems. . . . . . . . . . . . . . . . . . . . . . . . . 11–6
PS100-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–13 SMART Gas Analyzer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–16
PS120-1 or PS120-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–14 Solenoid Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–39 to 3–40
PS40-1 or PS40-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–12 Spare Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3–60
PUMP BOARD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–19 Special Application Sprinklers . . . . . . . . . . . . . . . . . . . 1–120 to 1–159
QRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–26 Specific Application Concealed Pendent Vertical Sidewall
RAPID RESPONSE® Residential Sprinkler Systems. . . . . 1–80 to 1–94 Window Sprinkler. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–129

RAVEN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–124 to 1–125 Sprinkler Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . 1–161 to 1–167

RAVEN Studio Sprinkler. . . . . . . . . . . . . . . . . . . . . . . . 1–122 to 1–123 Sprinkler Guards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–74 to 1–78

RC-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–8 Sprinkler Head Cabinet. . . . . . . . . . . . . . . . . . . . . . . . . 1–165 to 1–167

RCP-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–94 Sprinkler Reducers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8–3

Recessed Escutcheons. . . . . . . . . . . . . . . . . . . . . . . . . 1–161 to 1–162 Sprinklers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–2 to 1–187

Reduced Ends Model Longneck . . . . . . . . . . . . . . . . . . . . . . . . . . 8–6 Stand-Alone Nitrogen Generator. . . . . . . . . . . . . . . . . . . . . . . . . 11–3

Reducing Tees . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–21, 10–25 Standard Spray Sprinklers. . . . . . . . . . . . . . . . . . . . . . . . 1–2 to 1–26

Releasing Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–61 Storage Sprinklers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–45 to 1–78

Remote Inerting Station. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–10 Straight Fire Department Connections. . . . . . . . . . . . . . . . . . . . 3–61

Removal Tool. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–16 Strainer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–48 to 4–49

Repair Coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–10 Style 401, Two-Piece Adjustable Escutcheon. . . . . . . . . . . . . . . 1–163

Replacement Gaskets. . . . . . . . . . . . . . . . 10–6 to 10–7, 10–11, 10–32 Style 60, Two-Piece Flush Escutcheon. . . . . . . . . . . . . . . . . . . . 1–164

Residential Control Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–94 Style 65, One-Piece Flat Escutcheon. . . . . . . . . . . . . . . . . . . . . 1–163

Residential Shut Off Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–10 Super Centurion Duck Foot . . . . . . . . . . . . . . . . . . . . . . 4–52 to 4–53

Retard Chamber. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–8 Super Centurion Hydrant. . . . . . . . . . . . . . . . . . . . . . . . 4–50 to 4–52

Reverse Acting Medium Velocity Nozzle . . . . . . . . . . . . . . . . . . 1–173 Super Centurion Straight. . . . . . . . . . . . . . . . . . . . . . . . 4–50 to 4–51

RFII. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–17, 1–41 Supervisory Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . 5–21 to 5–24

RFII-HSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–25 Swing Type Flanged Check Valve. . . . . . . . . . . . . . . . . . . . . . . . 4–37

RFII-MRI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–18, 1–42 Swinging Hose Reels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–2

RFIII. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–43 Swinging Reel In Cabinet Hose Reels. . . . . . . . . . . . . . . . . . . . . . 9–4

Rigid Coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–2 Swinging Type Hose Reels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–2

Riser Check Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–9 System Testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–2

Riser Manifolds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–11 to 3–12 System Valves & Devices. . . . . . . . . . . . . . . . . . . . . . . . . 3–2 to 3–61

12-6
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
Tank Top Medium Velocity Nozzle . . . . . . . . . . . . . . . . . . . . . . . 1–172 VSR-S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–7
TD-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–13 Wafer Butterfly Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–50
Tee-Let Branch Outlets Threaded. . . . . . . . . . . . . . . . . . . . . . . . 8–8 Wafer Check Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–40
Tees. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–15 Wafer Double Door ANSI PN10/PN16 Flanges Check Valve. . . . . 4–38
Test & Drain Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–13 Wafer Style Butterfly Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–6
Test and Drain Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–58, 4–60 Wall-Mounted Nitrogen Generator. . . . . . . . . . . . . . . . . . . . . . . . 11–2
Test Kit - Flow Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–62 Waste Cones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–78
Test Kit - Sprinklers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–61 Water Motor Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–14
Test Kit for Flow Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–62 Water Supplies Proving Equipment . . . . . . . . . . . . . . . . 5–35 to 5–36
Test Kit for Sprinklers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–61 Water Tank Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . 5–31 to 5–38
TFP PH2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–127 Water Tank Equipment Water Level Indicator . . . . . . . . 5–31 to 5–32
TFP PH5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–128 Watermist Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–2 to 2–4
Threaded Check Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–42 Welding Branchlets Branch Outlets Grooved. . . . . . . . . . . . . . . 8–10
Threaded Pressure Relief Valve. . . . . . . . . . . . . . . . . . . 4–66 to 4–69 Wet Pilot, Dry Pilot, Electric Actuation, Remote Resetting or
TN-17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–182 Remote Resetting Pressure Reducing. . . . . . . . . . . . . . . . . . . . .3–44

TN-25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–181 Wet Pilot, Dry Pilot, or Electric Actuation . . . . . . . . . . . . . . . . . 3–51

Turbo-Lux3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–29 Wet Pipe Sprinkler Systems. . . . . . . . . . . . . . . . . . . . . . . 3–2 to 3–14

Twin Fluid. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–4 Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–175

Twin Plate Wafer Check Valve. . . . . . . . . . . . . . . . . . . . . . . . . . 4–39 Window Sprinklers, Horizontal & Pendent Vertical Sidewall . . . 1–130

TY-B. . . . . . . 1–2 to 1–7, 1–64 to 1–66, 1–137 to 1–142, 1–147 to 1–149 Window Wall Drencher Nozzle. . . . . . . . . . . . . . . . . . . . . . . . . . 1–175

TY-B & TY-FRB WMA-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–14


(Alternate Materials of Construction). . . . . . . . . . . . . . 1–152 to 1–154 WS™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–130
TY-B & TY-FRB (Poly-Stainless). . . . . . . . . . . . . . . . . . 1–155 to 1–156 ZONECHECK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–2, 5–10
TY-FRB. . . . . 1–9 to 1–16, 1–35 to 1–36, 1–67 to 1–69, 1–143 to 1–147
TY-FRFS, TY-FS & TY-FS Special. . . . . . . . . . . . . . . . . 1–135 to 1–136
TY-FRL. . . . . . . . . . . . . . . . . . . . . . . 1–22 to 1–24, 1–38, 1–72 to 1–73
TY-L. . . . . . . . . . . . . . . . . . . . . . . . . 1–19 to 1–21, 1–70 to 1–71, 1–151
Type 011 Sprinkler Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–78
Type 1 and 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–186
Type A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–174
UK Pump Initiation Boards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–19
ULTRA K-17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–55 to 1–56
Ultra Low Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–2
Ultra Low Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–2
Universal Casting Cup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–15
Upright. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–28, 1–46, 1–49
Upright & Pendent. . . . . . . . . . . . . . . . . . . . . . . . 1–57 to 1–61, 1–152
Upright & Pendent Foam-Water Sprinkler. . . . . . . . . . . . . . . . . 1–187
Upright, & Pendent, Special Response. . . . . . . . . . . . . . . . . . . . 1–148
Upright, Control Mode Specific Application. . . . . . 1–55 to 1–56, 1–63
Upright, Pendent & Horizontal Sidewall Sprinklers. . . . . . . . . . . 1–155
Upright, Pendent, & Recessed Pendent
. . . . . . . . . . . . 1–2 to 1–6, 1–9, 1–19, 1–22, 1–29, 1–96 to 1–98, 1–146
Vane Type Waterflow Alarm Switch With Electronic
Retard and Auto Test Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–3
Vent Trim. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–8
VENTURI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–27
Vertical Indicator Post. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–26
Vertical, Horizontal & Recessed Horizontal Sidewall Sprinklers.1–154
Viking Hoses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–7
VS-SP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–6
VSG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–5
VSR-AT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–3
VSR-EU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–4
VSR-FE-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–8
VSR-FEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–9

www.tyco-fire.com 12-7
Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.
About Johnson Controls:
At Johnson Controls, we transform the environments where people live, work, learn and play. From optimizing
building performance to improving safety and enhancing comfort, we drive the outcomes that matter most.
We deliver our promise in industries such as healthcare, education, data centers, and manufacturing. With
a global team of 105,000 experts in more than 150 countries and over 130 years of innovation , we are the
power behind our customers’ mission. Our leading portfolio of building technology and solutions includes
some of the most trusted names in the industry, such as Tyco®, ANSUL®, YORK®, Metasys®, Ruskin®, Titus®,
Frick®, PENN®, Sabroe®, Simplex® and Grinnell®. For more information, visit www.johnsoncontrols.com or
follow us @johnsoncontrols on Twitter

Europe North America


Kopersteden 1 1400 Pennbrook Parkway
Enschede, Overijssel 7547 TJ Lansdale, PA 19446 USA
The Netherlands Tel: +1 215-362-0700
Tel: +31 (0) 53 428 4444 Tel: 1 800-558-5236

Asia Pacific Middle East


2 Serangoon North Avenue 5 Internet City, Office Park Building
#07-01 Block D, Floor 3
Singapore 554911 Dubai, United Arab Emirates
Tel: +65 6577 4360 Tel: +971 4455 0700

Products displayed are for visual representation only. Actual products may vary. The information provided in this
brochure is provided for informational purposes only. The materials are general in nature; they are not offered as
advice on a particular matter and should not be relied on as such. The materials contained in this brochure are the
copyrighted property of Johnson Controls unless a separate copyright notice is placed on the material.

www.tyco-fire.com

© 2021 Johnson Controls. All rights reserved. Rev. 10-2021

Notice: This information is current as of 2021 and is provided for historical reference only. Some products may now be
discontinued or have modified specifications. Consult the current product data sheet for product specifications and information.

You might also like