PRO-POXY 200

MULTI-PURPOSE, MEDIUM VISCOSITY BONDING ADHESIVE

BENEFITS:
u Meets ASTM-C-881
Types I & II
u Super Strength
u Moisture
Insensitive
u Excellent
Adhesion
u Easy to Mix
1:1 Ratio
u Easy to Use
u Fast Set
u Corrosion
Inhibiting

PRO-POXY 200 provides corrosion


resistance to reinforcing steel and
excellent adhesion to concrete.

A.6
PRO-POXY 200
MULTI-PURPOSE, MEDIUM VISCOSITY BONDING ADHESIVE
DESCRIPTION still tacky. If coat of PRO-POXY 200 loses CAUTION
A solvent-free, moisture insensitive, 100% tackiness before pouring concrete, roughen • Component A – Irritant
solids, medium viscosity, two component epoxy surface to create bonding profile. Recoat • Component B – Corrosive
epoxy bonding agent and injection resin. with additional PRO-POXY 200 and proceed. • Product is a strong sensitizer. Use of safety
Recommended for structural crack repair for goggles and chemical resistant gloves are
TO BOND OLD TO OLD CONCRETE: Apply
larger cracks; .007–.030 in / .18–.76 mm. It recommended.
the mixed PRO-POXY 200 by brush, roller,
meets ASTM-C-881 Types I, II, Grade 2, • Use of a NIOSH/MSHA organic vapor
broom or spray to the substrate working in for
Classes B & C. It also meets USDA specifi- respirator is recommended if ventilation is
positive adhesion. While coating is tacky, join the
cations for use in food processing areas. An inadequate.
coated substrates and secure firmly into place.
excellent epoxy adhesive for use in crack • Avoid breathing vapors.
Glue-line should not exceed 1/8 in / 3.2 mm.
grouting by pressure injection or gravity-feed • Avoid skin contact.
and for making epoxy mortars and grouts. TO STRUCTURALLY REPAIR CRACKS
PRO-POXY 200 is slightly thicker than PRO- BY GRAVITY FEED: If cracks reflect FIRST AID
POXY 204. through slab, seal underside of cracks by but- EYE CONTACT: Flush immediately with
tering crack with PRO-POXY 300, PRO- water for at least 15 minutes. Contact physi-
USAGE POXY 300 FAST, or PRO-POXY 300 cian immediately.
• Structural bonding of fresh to hardened & PASTE. Otherwise, pour neat PRO-POXY
200 into vee-notched crack. Continue place- RESPIRATORY CONTACT: Remove person
old to old concrete
ment until crack is completely filled. to fresh air.
• Structural crack repair for larger cracks, i.e.
.007–.030 in / .18-.76 mm cracks TO VERTICALLY ANCHOR REBAR, DOW- SKIN CONTACT: Remove any contaminated
• Structural adhesive for concrete, masonry, ELS, AND THREADED ROD: For efficient clothing. Remove epoxy immediately with a
metal, wood, etc. transfer of stress, the annular space around bolt dry cloth or paper towel. Solvents should not
• Vertical anchoring of rebar, dowels, and should not exceed 1/8 in / 3.2 mm. The depth of be used as they carry the irritant into the skin.
threaded rod embedment is typically 9 times the bolt diameter. Wash skin thoroughly with soap and water.
Appearance: component A– white Grout with neat PRO-POXY 200. CURED EPOXY RESINS ARE INNOCU-
component B– gray TO PREPARE EPOXY MORTAR: Slowly OUS.
Shelf Life: 2 years in original unopened add 1 1/2 parts by loose volume of an oven-
container dried aggregate to 1 part of the mixed PRO- CLEANUP
Storage Conditions: Store at 40 - 95°F POXY 200. Mix until uniform in consistency EQUIPMENT: Uncured material can be
(5 - 35°C). Condition material to 65 - 85°F and color. removed with Unitex CITRI-CLEAN or
(18 - 29°C) before using other approved solvent. Cured material can
Gel Time (60 g mass): 30 min. at 73 ± 2°F PACKAGING only be removed mechanically.
(23°C) 1gal / 3.8 liter units (2 - .5 gal cans)
MATERIAL: Collect with absorbent mater-
2 gal / 7.6 liter units (2 - 1 gal cans)
APPLICATION ial. Flush area with water. Dispose of in
10 gal / 37.9 liter units (2 - 5 gal pails)
SURFACE PREPARATION: Surface must be accordance with local, state, and federal dis-
110 gal / 416.4 liter units (2 - 55 gal drums)
clean and sound. It may be dry or damp, but free posal regulations.
of standing water. Remove surface contaminants COVERAGE Disclaimer of Warranties: Neither manufacturer nor sell-
i.e. dust, grease, curing compounds, impregna- 1gal / 3.8L of epoxy covers approx. 80 sq ft / er have any knowledge or control concerning the pur-
tions, waxes, foreign particles and disintegrated 7.43sq m. chaser's use of the product. No expressed warranty is
materials. made by manufacturer or seller with respect to the
results of any use of the product or container that the
COMPLIANCES
Concrete: Sandblast or use other approved product comes in. No implied warranties including, but
ASTM-C-881: Types I & II not limited to, an implied warranty of merchantability or
mechanical means.
Grade 2 an implied warranty of fitness for a particular purpose
Steel: Sandblast to white metal finish. Classes B & C are made with respect to the product. Neither manufac-
turer nor seller assume any liability for personal injury,
MIXING: Pre-mix each component thoroughly. loss or damage resulting from the use of the product. In
LIMITATIONS the event that the product shall prove defective, buyer's
Place 1 part by volume of component A and 1
• Minimum substrate temperature is 40°F exclusive remedy shall be as follows: Seller or manufac-
part by volume of component B into a clean pail. turer shall, upon request of buyer, replace any quantity of
(5°C).
Mix thoroughly for 3 min. with low-speed drill the product which is proven to be defective or shall, at
• For best results use between 65 – 85°F its option, refund the purchase price of the product upon
and Jiffy type mixer (400–600rpm) until uni-
(18 – 29°C). return of the product. Manufacturer shall not be respon-
formly blended. Mix only the quantity that can
• Do not thin. Solvents will prevent proper sible for use of this product in a manner to infringe on
be used within its gel time. any patent held by others.
cure.
TO BOND FRESH CONCRETE TO HARD- • PRO-POXY 200 is a vapor barrier after
ENED CONCRETE: Apply by brush, roller, cure.
Contact UNITEX Technical
broom or spray to cured concrete substrate. • Minimum age of concrete must be 5–7
Services for further information
Place fresh concrete while PRO-POXY 200 is days. or installation instructions.

www.unitex-chemicals.com • email: mail.unitex-chemicals.com


3101 Gardner • Kansas City, MO 64120 • 816-231-7700 • 816-483-3149 Fax • 800-821-5846