115-241D 12" KIT 15.

7 KHZ W/COMP VID Y 1 4 26 MAR


01

LN LVL COMPONENT DESCRIPTION QUANTITY UM MEMO MRP OPR


WHERE REFERENCE LINE 1 LINE 2

USED

1 1 35-273-01 MAIN PCB W/COMP 115-241 1 EA 1


4

2 1 85-115-01 CRT 12" P31 RL MN1234P31AU 1 EA 1


4

3 1 80-113-04C YOKE HIGH IND (8 GAUSS) 1 EA 1


22

4 1 44-114-02B BARRIER SHIELD,CRT BD 1 EA 1


46

1 COBE LABS, MAGNAVOX


2 LABELS PER PROD STANDARD
3 USE 88-153-02
4 1 PC ON FLYBACK,1 PC ON CRT
5 USE CARTON 14-122-01
6 USE MOLD 14-122-03
7 USE INSERT PART 14-100-04
COMPUTRON DISPLAY SYSTEMS
PRODUCTION FORMAT
MODEL NUMBER : 115-241D DATE :September, 1999

CUSTOMER NAME : CGH SUPPLY VOLTAGE: 12.00 VDC


( COBE LABS ) SUPPLY CURRENT: 1.15 ADC
MARKETING NUMBER : 115DMK-12 HIGH VOLTAGE : 13.05 KVDC

USE QUANTUM 801A UNLESS NOTIFIED BY ENG.

VIDEO SIZE ( H X V ): 8.50 X 6.00 RCL 1 NORMAL VIDEO W/CHAR


VIDEO : COMPOSITE 1.0 VP-P C1 - 7
C2 - 5
CRT : 85-115-01 C3 - 4
YOKE : 80-113-04 C4 - 54
EXT BRIGHT : N.A SET OP 13.0
EXT CONTRAST : N.A.
RCL 2 INVERSE VIDEO WO/CHAR

PAD 10 - GROUND C1 - 4
C2 - 4
PAD 9 - N.C. C3 - 4
C4 - 4
PAD 8 - COMPOSITE 1.0 VP-P SET OP 13.2

PAD 7 - 12 VDC @ 1.05 AMPS RCL 3 HOR. USE ZERO BEAT


CAPACITOR. FOR THIS UNIT
PAD 6 - N.C. ONLY. FROM Tp OF R203 TO GND

PAD 5 - N.C. RCL 4 VERT. ZERO BEAT W/CHAR


SET OP 4.0
PAD 4 - N.C. OP 3.1

PAD 3 - N.C. LINES/ROW : 8


LINES : 302
PAD 2 - N.C. DISP ROWS : 24
DRV DELAY : 27
PAD 1 - GROUND DRV WIDTH : 3
VERT. FREE RUN : 52 HZ

COMMENTS : THIS UNIT MUST BE ZERO BEATED UNLESS OTHERWISE NOTED BY


ENGINEERING. ATTACH SPADE TERMINAL ( 45-115-05 ) TO CRT EAR
W/PLASTIC TIE STRAP. CHECK PRODUCTION STANDARD FOR LOCATION OF
CUSTOMER STICKER.
FOR BLK LEVEL SETUP LEFT SIDE OF R16 TO GND.
TORQUE SEAL ON FOLLOWING:
BLACK LEVEL, HORIZONTAL HOLD, VERTICAL HOLD, VERTICAL SIZE,
VERTICAL LINEARITY, CONTRAST AND BRIGHTNESS CONTROLS.
PROD ENG : QA SPR :

QUANTUM
TIMING PARAMETERS
HORIZONTAL VERTICAL

DOTS/CHR : 6 LINES/ROW : 8
TOTAL CHR : 5 7 LINES : 2 6 2
DISP CHR : 4 0 DISP ROWS : 2 4
DRV DELAY : 4 5 DRV DELAY : 2 7
DRV WIDTH : 5 DRV WIDTH : 3

KHZ : 1 5 . 7 0 0 HZ : 5 9 . 9 2
MHZ : 5 . 3 6 8 STEP : 2

OPTION PARAMETERS
SIGNAL GATING
COMPOSITE SYNC OP 1.0 0=OFF 1=ON
VERTICAL STEP OP 2.0 0=OFF 1=ON
HORIZONTAL DRIVE OP 3.1 0=OFF 1=ON
VERTICAL DRIVE OP 4.1 0=OFF 1=ON

SIGNAL POLARITY
COMPOSITE SYNC OP 5.0 0=NON-INVERTED 1=INVERTED
VERTICAL STEP OP 6.0 0=NON-INVERTED 1=INVERTED
HORIZONTAL DRIVE OP 7.0 0=NON-INVERTED 1=INVERTED
VERTICAL DRIVE OP 8.0 0=NON-INVERTED 1=INVERTED
VIDEO OP 13.0 0=NON-INVERTING/POSITIVE
1=INVERTED/POSITIVE
2=NON-INVERTED/NEGATIVE
3=INVERTED/NEGATIVE

INTERLACE MODE OP 9.0 0=NON-INTERLACE


1=INTERLACED SYNC ONLY
3=INTERLACED SYNC & VIDEO

VIDEO MODE OP 10.0 0=MONOCHROME 1=COLOR

DUTY CYCLE OP 11.0 0=50% 1=100% (OP 12.0)


0 OR 1=100% (OP 12.2)

CHARACTER CLOCKING MODE OP 12.0 0=SIGNAL-PHASE


2=DUAL-PHASE
HORIZONTAL SKEW OP 14.0 SKEW RIGHT 0-3 DOTS

VERTICAL SKEW OP 15.0 SKEW DOWN 0-9 DOTS

CURSOR OP 16.2 0=OFF


1=FAST BLINK
2=SLOW BLINK
3=ON CONTINUOUS

You might also like