0% found this document useful (0 votes)
20 views6 pages

Quick Guide Evo 48 Paqradox PDF

This document provides a quick guide for programming the EVO48 security panel. It explains how to reset connected modules, program zones, activate end-of-line resistance, configure alarm parameters such as sirens and timings, and enroll remote controls, wireless zones, and keyboard programming.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
20 views6 pages

Quick Guide Evo 48 Paqradox PDF

This document provides a quick guide for programming the EVO48 security panel. It explains how to reset connected modules, program zones, activate end-of-line resistance, configure alarm parameters such as sirens and timings, and enroll remote controls, wireless zones, and keyboard programming.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Quick Programming Guide EVO48

Programming Menu

Press and hold 0 until the panel indicates to enter the installer code (000000)

Once inside the programming, you will be asked to enter the number of the field you wish to modify.
this will be 4 digits and from now on we will show it in brackets; Example: [4005]

Reset the Modules on the data bus

Upon entering this field, the panel will scan for connected devices and remove them.
those who are no longer connected

In case you have connected more than 127 modules to your EVO48 panel at any time.
this field will organize all existing modules giving us more space.
Zone programming

[0400]

The following parameters are carried out

a) Zone number

b) Serial number and input number

c) Zone Parameters

(01)(*2***** )

d) Reporting codes

e) Zone labels

End-of-line resistance activation

Activate option 7 in field [3033]


Panic

3123 panic (1-6)

1 Police Panic On/Off

Medical Panic On/Off

3 Fire Panic On/Off

4 Police Panic Audible/Only report

5 Medical Panic Audible/Only report

6 Fire panic

System Times
Departure time

3108 Partition 1 (001 to 255 sec)

3208 Partition 2 (001 to 255 sg)

Entry time

Partition 1

3111 Entry time 1 (001 to 255 seconds)

3112 Entry time 2 (001 to 255 sec)

Partition 2

3211 Entry time 1 (001 to 255 sec)

3212 Entry time 2 (001 to 255 sec)

Departure Time

3108 Departure time partition 1


3208 departure time partition 2

Mermaid

3032 Activates or deactivates the siren for the partition (1-2)

3036 Option [8] Siren in communication failure

3124 Siren pulse partition 1 (1-6)

3224 Siren sound pulse partition 2 (1-6)

It emits two beeps when disarmed.

It emits a beep when armed

3 Emits a beep every second for 60 seconds before auto-arming the partition

4 Emits a beep every second during the exit delay

5 Emit a beep every second during the entry delay

It beeps once when armed and twice when disarmed when done with a remote control.

Option 3 Prevents arming if there is a problem with the siren

Functions with a single key

3125 A single key (1-6)

Quick activation feature option Button

[1] Regular Armed ARM

[2] Home Assembly STAY

[3] Instant Home Assembly (no output delay) 5

[4] Forced Armament FORCE

5 Unarmed in Home Mode DISARM

6 Cancellation of zones BYP

[7] Show events 7


3122 Auto-Assembly

Option [1] On/Off

Option [3] On/Off Auto-Arm Stay

3101 Timer of self-assembly

Remote controls

2940 Default template for remote control (00-15)

2900-2915 Remote control templates

2941 Assign template to user, select user (000-032), assign template (00-15)

The control is assigned to the user during the process of registering user codes.

To register the keychains to a user, you only need to press one of the buttons when the
the keyboard indicates it when registering the user codes.

Markup options

3036 Option [3] Marked On/Off

3071-3074 Teléfonos 1-4

3061 Account number partition 1

3062 Account number partition 2

3070 Communication format phone 1-4

1 Ademco Slow

2 Silent Knight Fast

3 Sescoa

4 Ademco Express

5 Pager

6 SIA FSK
7 Ademco Contact ID

4031 Put all reports in FF

NOTE.- Field 4031 must be activated for the panel to communicate.

Register wireless zones

To activate wireless areas, the following steps must be carried out.

The serial number of the wireless sensors must be registered within the RTX3 module.
to do this follow these steps:

1) Enter the programming mode of the panel and access field [4003], once inside.
from this field enter the serial number of your RTX3 receiver

Now you must access the field where the serial number of the sensor will be recorded.
this in the fields [101] to [132]

3) Exit the module programming using the DELETE key.

2) Now you will have to program the zone like any other, the only difference will be the number of
series which will correspond with that of the receiver, the input number will be the one provided in the
module programming, example: [101] =Input 001

Keyboard programming

4003 Device serial number

Within keyboard programming

Field 004

Option [4] Chime

Option [1] Keyboard muted