Specifications
Eaton 118702
Eaton ESR5 Safety relay emergency
stop/protective door, 24VDC/AC, 3 enabling
paths
General specifications
PRODUCT NAME Eaton ESR5 Safety relay
CATALOG NUMBER 118702
MODEL CODE ESR5-NO-31-24VAC-DC
EAN 4015081168422
PRODUCT
114.5 mm
LENGTH/DEPTH
PRODUCT HEIGHT 99 mm
PRODUCT WIDTH 22.5 mm
PRODUCT WEIGHT 0.164 kg
2014/30/EU
UL File No.: E29184
EN ISO 13849-1
UL report applies to both
US and Canada
CE
UL Category Control No.:
NKCR; NKCR7
UL 508
IEC 62061
CERTIFICATIONS
UL
EN 50178
Certified by UL for use in
Canada
IEC/EN 60204
IEC 61508, Parts 1-7
CSA-C22.2 No. 14-95
CSA Class No.: 3211-83;
3211-03
Machines 2006/42/EG
Replacement: ESR5-NO-
CATALOG NOTES
31-24VDC (EP-401062)
GLOBAL CATALOG 118702
Product specifications Resources
eaton-esr5-safety-relay-
• Emergency stop BROCHURES brochure-br049005en-en-
category 0; us.pdf
emergency
TYPE eaton-product-overview-
switching off
• Feedback circuit CATALOGS for-machinery-catalogue-
• Protective door ca08103003zen-en-us.pdf
eaton-safety-relays-esr5-
Rail mounting possible CHARACTERISTIC CURVE safety-relay-characteristic-
Top-hat rail fixing curve.eps
MOUNTING METHOD
(according to IEC/EN
eaton-safety-relay-
60715, 35 mm) DECLARATIONS OF
declaration-of-conformity-
CONFORMITY
OPERATING eu250613en.pdf
55 °C
TEMPERATURE - MAX
eaton-safety-relays-relay-
OPERATING esr5-safety-relay-
-20 °C
TEMPERATURE - MIN dimensions-002.eps
6 kV between input circuit eaton-general-esr5-safety-
and enable current paths relay-symbol-002.eps
Safe insulation DRAWINGS
Reinforced insulation eaton-safety-relays-relay-
FEATURES
3 Non-delayed enable esr5-safety-relay-3d-
current paths drawing.eps
Automatic reset
Basic insulation eaton-general-esr5-safety-
relay-symbol.eps
The panel builder is
responsible for the DA-CE-ETN.ESR5-NO-31-
ECAD MODEL
temperature rise 24VAC-DC
10.10 TEMPERATURE RISE
calculation. Eaton will INSTALLATION
IL05013029Z
provide heat dissipation INSTRUCTIONS
data for the devices.
MANUALS AND USER
MN049008_EN
Is the panel builder's GUIDES
responsibility. The
10.11 SHORT-CIRCUIT eaton-safety-relays-
specifications for the
RATING drawings-esr5-no-xx-
switchgear must be
24vdc.dwg
observed.
MCAD MODEL
Is the panel builder's eaton-safety-relays-3d-
responsibility. The models-esr5-no-xx-
10.12 ELECTROMAGNETIC 24vdc.stp
specifications for the
COMPATIBILITY
switchgear must be eaton-safety-relays-esr5-
observed. safety-relay-wiring-
The device meets the diagram-009.eps
requirements, provided
10.13 MECHANICAL eaton-safety-relays-esr5-
the information in the
FUNCTION WIRING DIAGRAMS safety-relay-wiring-
instruction leaflet (IL) is
diagram-008.eps
observed.
10.2.2 CORROSION Meets the product eaton-safety-relays-esr5-
RESISTANCE standard's requirements. safety-relay-wiring-
diagram-007.eps
10.2.3.1 VERIFICATION OF
Meets the product
THERMAL STABILITY OF
standard's requirements.
ENCLOSURES
10.2.3.2 VERIFICATION OF Meets the product
RESISTANCE OF standard's requirements.
INSULATING MATERIALS
TO NORMAL HEAT
10.2.3.3 RESIST. OF
INSUL. MAT. TO
Meets the product
ABNORMAL HEAT/FIRE
standard's requirements.
BY INTERNAL ELECT.
EFFECTS
10.2.4 RESISTANCE TO
Meets the product
ULTRA-VIOLET (UV)
standard's requirements.
RADIATION
Does not apply, since the
10.2.5 LIFTING entire switchgear needs to
be evaluated.
Does not apply, since the
10.2.6 MECHANICAL
entire switchgear needs to
IMPACT
be evaluated.
Meets the product
10.2.7 INSCRIPTIONS
standard's requirements.
10.3 DEGREE OF Does not apply, since the
PROTECTION OF entire switchgear needs to
ASSEMBLIES be evaluated.
10.4 CLEARANCES AND Meets the product
CREEPAGE DISTANCES standard's requirements.
10.5 PROTECTION Does not apply, since the
AGAINST ELECTRIC entire switchgear needs to
SHOCK be evaluated.
10.6 INCORPORATION OF Does not apply, since the
SWITCHING DEVICES AND entire switchgear needs to
COMPONENTS be evaluated.
10.7 INTERNAL
Is the panel builder's
ELECTRICAL CIRCUITS
responsibility.
AND CONNECTIONS
10.8 CONNECTIONS FOR Is the panel builder's
EXTERNAL CONDUCTORS responsibility.
10.9.2 POWER-
Is the panel builder's
FREQUENCY ELECTRIC
responsibility.
STRENGTH
10.9.3 IMPULSE Is the panel builder's
WITHSTAND VOLTAGE responsibility.
10.9.4 TESTING OF
Is the panel builder's
ENCLOSURES MADE OF
responsibility.
INSULATING MATERIAL
ELECTRIC CONNECTION
Screw connection
TYPE
Approval for TÜV
Feedback circuit
FITTED WITH: Approval according to UL
Start input
Detachable clamps
POLLUTION DEGREE 2
Dry heat to IEC 60068-2-2
Cold to EN 60068-2-1
CLIMATIC PROOFING
Damp heat, constant, to
IEC 60068-2-3
RATED IMPULSE
WITHSTAND VOLTAGE 4000 V AC
(UIMP)
AIR PRESSURE 795 - 1080 hPa (operation)
ALTITUDE Max. 2000 m
CATEGORY (EN 954-1) 4
IP20
Terminals: IP20
DEGREE OF PROTECTION Installation location: ≥ IP54
Enclosure: IP20
Clearance in air and
creepage distances
ENVIRONMENTAL according to EN 50178, UL
CONDITIONS 508, CSA C22.2, No. 14-95
Condensation: Non-
condensing
NUMBER OF INPUTS One- and two-channel
2-channel
FUNCTIONS
1-channel
SAFETY PERFORMANCE
Level e
LEVEL (EN ISO 13849-1)
AMBIENT OPERATING
55 °C
TEMPERATURE - MAX
AMBIENT OPERATING
-20 °C
TEMPERATURE - MIN
AMBIENT STORAGE
70 °C
TEMPERATURE - MAX
AMBIENT STORAGE
-40 °C
TEMPERATURE - MIN
EQUIPMENT HEAT
DISSIPATION, CURRENT- 0W
DEPENDENT PVID
HEAT DISSIPATION
0W
CAPACITY PDISS
HEAT DISSIPATION PER
POLE, CURRENT- 0W
DEPENDENT PVID
LIFETIME 240 month
NOMINAL CURRENT 30 A
NUMBER OF OUTPUTS
(SAFETY RELATED, 0
DELAYED) WITH
CONTACT
NUMBER OF OUTPUTS
(SAFETY RELATED,
0
DELAYED,
SEMICONDUCTORS)
NUMBER OF OUTPUTS
(SAFETY RELATED,
3
UNDELAYED) WITH
CONTACT
NUMBER OF OUTPUTS
(SAFETY RELATED,
0
UNDELAYED,
SEMICONDUCTORS)
NUMBER OF OUTPUTS
(SIGNALING FUNCTION,
0
DELAYED) WITH
CONTACT
NUMBER OF OUTPUTS
(SIGNALING FUNCTION,
0
DELAYED,
SEMICONDUCTORS)
NUMBER OF OUTPUTS
(SIGNALING FUNCTION,
1
UNDELAYED) WITH
CONTACT
NUMBER OF OUTPUTS
(SIGNALING FUNCTION,
0
UNDELAYED,
SEMICONDUCTORS)
RATED CONTROL SUPPLY
VOLTAGE (US) AT AC, 50 26.4 V
HZ - MAX
RATED CONTROL SUPPLY
VOLTAGE (US) AT AC, 50 0V
HZ - MIN
RATED CONTROL SUPPLY
VOLTAGE (US) AT AC, 60 24 V
HZ - MAX
0.6 x 3.5 mm, Terminal
screws
SCREWDRIVER SIZE
2, Terminal screw, Pozidriv
screwdriver
VOLTAGE TYPE AC/DC
CONNECTION TYPE M3 screw terminals
MOUNTING POSITION As required
35 W max., inductive load
(τ = 40 ms), at 110 V DC
BREAKING POWER 40 W max., inductive load
(τ = 40 ms), at 48 V DC
48 W max., inductive load
(τ = 40 ms), at 24 V DC
1500 VA, max., resistive
load (τ = 0 ms), at 250 V AC
288 W max., resistive load
(τ = 0 ms), at 48 V DC
77 W max., resistive load (τ
= 0 ms), at 110 V DC
144 W max., resistive load
(τ = 0 ms), at 24 V DC
88 W max., resistive load (τ
= 0 ms), at 220 V DC
33 W max., inductive load
(τ = 40 ms), at 220 V DC
OVERVOLTAGE
III
CATEGORY
10A gL/gG, NEOZED (N/O),
Output fuse, External,
SHORT-CIRCUIT Output data
PROTECTION RATING 6A gL/gG, NEOZED (N/C),
Output fuse, External,
Output data
DUTY FACTOR 100 %
EMITTED INTERFERENCE According to EN 61000-6-4
CURRENT 140 mA, AC
CONSUMPTION 65 mA, DC
Contacts: silver tin oxide,
gold plated (AgSnO2, 0.2
MATERIAL µ m Au)
Enclosure: Polyamide (PA),
not reinforced
INTERFERENCE According to EN 662061_x
IMMUNITY According to EN-61000-6-2
TIGHTENING TORQUE 0.6 Nm, Screw terminals
MOUNTING WIDTH 22.5 mm
Module used to safely
interrupt electrical circuits
Monitoring of position
switches
SUITABLE FOR Monitoring of emergency-
stop circuits
Safety relay for monitoring
emergency stop and
protective door switch
RELATIVE HUMIDITY < 75 %
Status indication of
LED INDICATOR SmartWire-DT network:
Green LED
100 ms typ. (K1, K2 - for
PICK-UP TIME UN automatic mode)
100 ms typ. (at Uₑ in
automatic mode)
LIFESPAN, MECHANICAL 10,000,000 Operations
∞ ms, Simultaneity for
INPUT
inputs 1/2
RECOVERY TIME 1000 ms
RESISTANCE 50 Ω (impedance)
INRUSH CURRENT 0.025 - 6 A
MODEL Basic device
SAFETY TYPE (IEC 61496-
None
1)
SHORT-CIRCUIT CURRENT 2.3 A, Input data
10 - 150 Hz, Amplitude:
VIBRATION RESISTANCE 0.15 mm, Acceleration: 2 g,
(IEC/EN 60068-2-6)
300,000 switching cycles,
SAFETY PARAMETER (EN B10d
ISO 13849-1) Cat. 4, Category
PL e, Performance level
2 x (0.25 – 1) mm², flexible
with ferrule
24 - 12 AWG, solid or
stranded
TERMINAL CAPACITY
1 x (0.2 – 2.5) mm², solid
2 x (0.2 – 1) mm², solid
1 x (0.25 – 2.5) mm²,
flexible with ferrule
RATED CONTROL SUPPLY
VOLTAGE (US) AT AC, 60 20.4 V
HZ - MIN
RATED CONTROL SUPPLY
VOLTAGE (US) AT DC - 24 V
MAX
RATED CONTROL SUPPLY
VOLTAGE (US) AT DC - 0V
MIN
RATED INSULATION
250 V
VOLTAGE (UI)
RATED OPERATIONAL
CURRENT FOR SPECIFIED 0A
HEAT DISSIPATION (IN)
RELEASE-DELAY - MAX 0s
RELEASE-DELAY - MIN 0s
STATIC HEAT
DISSIPATION, NON-
5.16 W
CURRENT-DEPENDENT
PVS
STRIPPING LENGTH
7 mm
(MAIN CABLE)
SWITCHING VOLTAGE 250 V
PRODUCT CATEGORY Electronic safety relays
Finger and back-of-hand
proof, Protection against
PROTECTION direct contact when
actuated from front (EN
50274)
SIL (IEC 61508) 3
PERMISSIBLE TOTAL Approx. 50 Ω (input and
CABLE RESISTANCE starting circuits for UN)
POWER LOSS Normally 5.16 W
1.6 W (DC operated)
POWER SUPPLY CIRCUIT 3.4 W (AC operated 50/60
Hz)
66 Months (Low Demand)
PROOFTEST 240 Months (High
Demand)
QUADRATIC
72 A² (ITH² = I1² + I2² + I3²)
SUMMATION CURRENT
230 V AC
24 V AC/DC (power supply)
RATED OPERATIONAL
VOLTAGE Approx. 24 V DC at input,
starting and feedback
circuit
Normally 10 ms (dual-
RESET TIME channel)
45 ms (single-channel)
SIL 3, Safety integrity level
SIL 3, Safety integrity level,
In accordance with IEC
61508
SAFETY PARAMETER (IEC Cat. 4, Category
62061) SILCL 3, Safety integrity
level claim limit
5.05 x 10-10, PFHd,
Probability of failure per
hour
6 A N/C, Limiting
UNINTERRUPTED continuous current
CURRENT 6 A N/O, Limiting
continuous current
Short-circuit proof, 24 V,
Fuse for control circuit
SHORT-CIRCUIT
supply, Control circuit
PROTECTION
Fuse 6 A gL/gG, For output
circuits, External
STOP CATEGORY (IEC
0
60204)
SWITCHING CAPACITY 4 A at 360 O/h, DC-13 at 24
V, Outputs
In accordance with IEC
60947-5-1, Outputs
3 A at 3600 O/h, AC-15 at
230 V, Outputs
2.5 A at 3600 O/h, DC-13 at
24 V, Outputs
0.4 W
4 A at 360 O/h, AC-15 at
230 V, Outputs
SWITCHING FREQUENCY Max. 0.5 Hz, Input data
POWER CONSUMPTION 5.16 W
CONTROL VOLTAGE 1 -
24 V
MIN
CONTROL VOLTAGE 1 -
24 V
MAX
CONTROL VOLTAGE 2 -
24 V
MIN
CONTROL VOLTAGE 2 -
24 V
MAX
CONTROL VOLTAGE 1
AC/DC
TYPE
CONTROL VOLTAGE 2
AC/DC
TYPE
VOLTAGE TYPE OF
AC/DC
SUPPLY VOLTAGE
VOLTAGE TYPE OF
AC/DC
OPERATING VOLTAGE
RATED SWITCH CURRENT 6A
SUPPLY VOLTAGE AT AC,
24 V
50 HZ - MIN
SUPPLY VOLTAGE AT AC,
24 V
50 HZ - MAX
SUPPLY VOLTAGE AT AC,
24 V
60 HZ - MIN
SUPPLY VOLTAGE AT AC,
24 V
60 HZ - MAX
SUPPLY VOLTAGE AT DC -
24 V
MIN
SUPPLY VOLTAGE AT DC -
24 V
MAX
OPERATING VOLTAGE AT
24 V
AC, 50 HZ - MIN
OPERATING VOLTAGE AT
24 V
AC, 50 HZ - MAX
OPERATING VOLTAGE AT
24 V
AC, 60 HZ - MIN
OPERATING VOLTAGE AT 24 V
AC, 60 HZ - MAX
OPERATING VOLTAGE AT
24 V
DC - MIN
OPERATING VOLTAGE AT
24 V
DC - MAX
PROJECT NAME:
PROJECT NUMBER:
PREPARED BY:
DATE:
Eaton Corporation plc Follow us on social media to get the
Eaton House latest product and support
30 Pembroke Road information.
Dublin 4, Ireland
Eaton.com
© 2025 Eaton. All Rights Reserved.