Switching Power Supply
Type SPD 120W
DIN rail mounting
• Installation on DIN Rail 7.5 or 15mm
• Short circuit protection
• PFC available
• High efficiency
• Power ready output
• LED indicator for DC power ON
• LED indicator for DC low
• Parallel versions available
• Compact dimensions
• UL, cUL listed and TUV/CE approved
Product Description Ordering Key SP D 24 120 1 BFP
The Switching power installation is on a DIN rail Model
supplies SPD series are and compact dimensions Mounting ( D = Din rail )
specially designed to be and performance are a must. Output voltage
used in all automation Output power
application where the Input Type
Optional features
Approvals Input type: 1= single phase
Optional Features
Description code
Plug-in connectors Bxx
With P.F.C. xFx
With Parallel function xxP
Output performances
Model Rated output Output Voltage Trim Range1) DC on LED (VDC) DC low LED (VDC) Typical
Voltage (VDC) Current (A) Min. VDC Max. VDC Min. Max. Min. Max. Efficiency
SPD12 12 10 11.4 14.5 10 11 10 11.2 84%
SPD24 24 5 22.5 30 21 22 20.5 22.5 86%
SPD48 48 2.5 45 55 42 44 41 45 87%
Output data
Output voltage accuracy ± 1% max Ouput Voltage accuracy +1% (factory adjusted)
Line regulation ± 0.5% Temperature coefficient ± 0.3%/°C
Load regulation Hold up Time Vi = 115Vac 25ms
Non parallel model ± 1% Hold up time Vi = 230Vac 30ms
Parallel model ± 5% Minimum load 5%
Temp. coefficient ± 0.3% / °C Parallel Operation 3 units max.
Transient recovery time 300 ms (only specific models)
Ripple and noise 50mVpp
1)N.A. on parallel model. Output voltage is fixed in house, cannot be trimmed by user.
Specifications are subject to change without notice 1
Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected]
Switching Power Supply
Type SPD 120W
DIN rail mounting
Input data
Rated input voltage 115/230 selectable Frequency range 47- 63 Hz
Voltage range Inrush current
AC in, 115 selected 93 - 132 Vac Vi= 115Vac 24A
AC in, 230 selected 186 - 264 Vac Vi= 230Vac 48A
DC in, only 230 selected 210 - 370 Vdc P.F.C. (optional) 0.7
Controls and Protections
Input Fuse T4A/250Vac internal* Power ready (only SPD 24)
Overvoltage Protection 125 – 145% Threshold at start up 21.1-23.1
(contact closed)
Output Short Circuit Current limited Threshold after start up 20.6-19.0
Rated Overload Protection 105-125% (contact open)
Contact rating at 60Vdc 0.3A
insulation 500Vdc
* Not replaceable by user.
General data (@ nominal line, full load, 25°C )
Ambient temperature -10°C to 71°C Cooling Free air convection
Derating (>60°C to +71°C) 2.5% / °C Switching frequency 80kHz
Ambient humidity 20 to 95%RH MTBF (MIL-HDBK-217F) 480.000h
Storage -25°C to +85°C Case material Metal (powder painted aluminium)
Protection degree IP20 Dimensions L x W x D 125 x 63.5 x 126
Without P.F.C. 640g
With P.F.C. 860g
Approvals and EMC
Insulation voltage I / O 3.000Vac min CE EN50081-1
Insulation resistance 100Mohm min EN55022 class B
EN61000-3-2
UL / cUL UL508 listed, UL60950-1, EN61000-3-3
Recognised EN50082-1
TUV EN60950 EN55024
Block diagrams
2)
L Fuse 1) Vo +
Inrush Current
Line P.F.C. Smoothing Switching
Limiter and Rectifier
Filter Circuit Circuit Device Current
Rectifier
N Detection Vo -
Y PWM
Controller Reference &
Opto -
isolation Error Amp. Vout 4)
ADJ.
Opto - Over Voltage
isolation Detection
DCON
Output Level (Green LED)
115V/230V Detection DCLOW
selected (Red LED)
RDY 3)
(Relay Contact)
1) only with P.F.C. option
2) only with parallel option
3) for 24VDC
SPD 24 models
4) N.A. on parallel version
2 Specifications are subject to change without notice
Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected]
Switching Power Supply
Type SPD 120W
DIN rail mounting
Pin assignement and front controls
Pin No. Designation Description
1 RDY (only SPD 24) DC OK, relay normally open contact
2 RDY (only SPD 24) DC OK, relay normally open contact
3 + Positive output terminal
4 + Positive output terminal
5 - Negative output terminal
6 - Negative output terminal
7 GND Ground terminal to minimise High frequency emissions
8 L Phase input ( no polarity with DC input )
9 N Neutral input ( no polarity with DC input )
DC ON DC output ready LED
DC LO DC low indicator LED
Vout ADJ. Trimmer for fine output voltage adjustment
115/230 Input voltage selection switch
Installation Derating Diagram
VENTILATION / COOLING:
Power out (%)
• Normal air convection
• 25mm of free space along all sides to allow good 100
cooling 90
SCREW CONNECTIONS: 80
• 10-24AWG Flexible or solid cable. 8mm stripping
70
recommended
PLUG IN CONNECTORS: 60
• 10-24AWG Flexible or solid cable. 7mm stripping 50
recommended 40
30
20
10
0
-10 0 5 10 55 60 65 70 75 80
Temperature (°C)
Mechanical Drawings
116 (4.57) 10.0 (0.39) 6 I
6 I
DC INPUT
N.C. N.C.
125.0 (4.92)
125.0 (4.92)
142.4 (5.59)
AC INPUT
63.5 (2.5) 63.5 (2.5)
7 9 7 9
Specifications are subject to change without notice 3
Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected]