UNIT 1
RECENT TRENDS IN POWER GENERATION
Power generation is undergoing a significant transformation due to environmental concerns,
technological advancements, and the need for energy security. Here are the key recent
trends:
1. 🔋 Shift Towards Renewable Energy
Increasing share of solar, wind, biomass, and small hydro in the energy mix.
Example: India aims for 500 GW of non-fossil fuel capacity by 2030.
2. ⚡ Decentralized Generation / Distributed Energy Resources (DERs)
Power is no longer just generated in large power stations.
Rooftop solar panels, community wind farms, and local biomass plants are gaining
popularity.
3. 🧠 Smart Grid Development
Integration of digital technology to monitor and control electricity flow.
4. 🔄 Hybrid Power Systems
Use of multiple energy sources (e.g., solar + wind + battery) in a single plant.
5. 🏭 Supercritical and Ultra-Supercritical Thermal Power Plants
Use higher temperature and pressure steam to increase efficiency and reduce
emissions.
These are replacing older, less efficient coal power plants.
Helps in reducing the carbon footprint of thermal power generation.
6. 🌱 Carbon Capture and Storage (CCS)
Capturing CO₂ from fossil fuel-based power plants before it enters the atmosphere.
Still in early stages in India but being researched and piloted globally.
7. 💨 Green Hydrogen Production
Electricity (preferably from renewables) is used to split water (electrolysis) to create
hydrogen.
8. 🌍 Global Interconnection and Grid Synchronization
Countries are moving toward transnational grids (e.g., International Solar Alliance, One
Sun One World One Grid).
Aim: Share renewable energy across borders for stability and efficiency.
9. 🏘️ Prosumers and Demand Response
Consumers can now also be producers (prosumers) by installing solar and selling excess
electricity back to the grid.
Conventional Energy Generation in Haryana
Haryana's conventional energy primarily stems from coal-based thermal power plants, with
nuclear energy projects under development.
🔥 Thermal Power Plants
The state operates several coal-fired thermal power stations
Deenbandhu Chhotu Ram Thermal Power Plant (Yamunanagar): 600 MW (2×300 MW)
Panipat Thermal Power Station: 1,210 MW
Rajiv Gandhi Thermal Power Station (Hisar): 1,200 MW
An additional 800 MW unit is under construction at Yamunanagar, expected to be
commissioned by March 2029.
☢️ Nuclear Power (Upcoming)
Gorakhpur Nuclear Power Plant (Fatehabad): Planned capacity of 2,800 MW (4×700 MW).
The first phase (1,400 MW) is under construction, with commissioning expected by 2029.
Non-Conventional Energy Generation in Haryana
Haryana is actively expanding its renewable energy portfolio, focusing on solar, biomass,
wind, and small hydro projects.
☀️ Solar Energy
As of 2025, Haryana has an installed solar capacity of approximately 1,300 MW:
Solar-Powered Water Pumps: Over 154,000 installations contributing 822 MW.
Rooftop Solar Systems: Approximately 30,200 installations generating around 517 MW.
The state aims to achieve 6,000 MW of solar capacity by 2030, including 3,200 MW from
ground-mounted projects, 1,600 MW from rooftop installations, and 1,200 MW through the
solarization of irrigation pumps.
🌾 Biomass Energy
Haryana utilizes agricultural residues for biomass energy:
Biomass-Based Projects: 50 MW capacity established through stubble-based initiatives.
💨 Wind Energy
The state has approved three wind power projects totaling 340 MW, to be developed in the
Aravalli Hill Ranges across Mahendragarh, Gurgaon, and Mewat districts.
💧 Small Hydro Projects
Haryana has implemented small hydro projects, including a 73.2 MW capacity project in the
Yunnan district, contributing to its renewable energy mix.
World and India trend
Introduction
Electric power generation is essential for economic development and social well-being. The
sources used to generate electricity can be broadly categorized into conventional (non-
renewable) and non-conventional (renewable) energy resources. While conventional sources
like coal, oil, and natural gas have been the backbone of power generation for decades,
increasing environmental concerns and sustainability goals have led many countries to shift
toward renewable sources like solar, wind, hydro, and biomass.
In this context, India and various developed countries have adopted diverse energy strategies
to balance energy security, economic growth, and environmental sustainability.
Power Generation in India
India is the world’s third-largest producer and consumer of electricity. The country’s energy
generation is a mix of conventional and non-conventional sources.
1. Conventional Sources in India
Conventional sources dominate India’s energy sector. These include:
🔥 Thermal Power: Mainly coal-based, accounting for over 45% of the total installed
capacity. Thermal plants are widespread and play a crucial role in base-load generation.
⛽ Natural Gas and Diesel: Used for quick start and peak-load power generation.
☢ Nuclear Power: A small but significant contributor, with a vision to increase its share
for clean base-load energy.
Despite their reliability, these sources are associated with high greenhouse gas emissions, air
pollution, and environmental degradation.
2. Non-Conventional Sources in India
India has made significant progress in renewable energy:
☀ Solar Energy: India is one of the world leaders in solar power capacity, supported by
schemes like PM-KUSUM and rooftop solar programs.
💨 Wind Energy: Mostly concentrated in Tamil Nadu, Gujarat, and Maharashtra.
💧 Hydro Power: Includes large and small hydro plants.
🌿 Biomass and Waste-to-Energy: Utilized mainly in rural and agricultural regions.
India’s policy commitment to climate action is reflected in its National Solar Mission and
targets to achieve 500 GW of non-fossil capacity by 2030.
Power Generation in Developed Countries
Developed nations like Germany, the USA, and others have transitioned significantly toward
cleaner energy systems.
1. Germany
Germany has adopted the “Energiewende” (energy transition) policy:
Over 55% of electricity is generated from renewables.
Wind (both onshore and offshore) and solar are dominant.
Nuclear power is being phased out.
The country heavily invests in smart grids, storage, and green hydrogen.
Germany serves as a model for integrating high shares of renewable energy into the grid while
maintaining reliability.
2. United States
The U.S. has a diverse energy mix:
Natural gas is the largest single source of electricity, followed by renewables, nuclear, and
coal.
Wind and solar have grown rapidly, supported by tax credits and state-level mandates.
Hydroelectricity remains significant, especially in western states.
The U.S. is also investing in battery storage and grid modernization.
3. Other Countries
🇫🇷 France: Heavily reliant on nuclear energy (~70%) for clean and stable electricity.
🇸🇪 Sweden: Uses a combination of hydro, nuclear, and wind; aims for 100% renewable
power.
Comparative Insights
Developed countries are focused on reducing carbon footprints and have adopted
aggressive renewable energy targets.
India, while still reliant on conventional sources, is making rapid progress in renewable
energy deployment, especially in solar and wind.
Both India and developed nations recognize the need for a balanced mix of energy
sources to ensure sustainability, energy security, and economic development.
Conclusion
The global trend in power generation is shifting from conventional to non-conventional
energy sources due to environmental concerns, energy security needs, and technological
advancements. While developed countries have already made substantial progress, India is
emerging as a major player in the renewable energy domain. The collaborative global effort
toward clean energy is not only a technological transformation but also a crucial step toward
combating climate change and ensuring a sustainable future for all.
Interconnected Generation of Power Plants
Introduction
Interconnected generation of power plants refers to the system in which multiple power
stations—thermal, hydro, nuclear, or renewable—are electrically linked through a common
transmission and distribution network. This interconnection allows electricity to be
generated at various locations and distributed across regions efficiently and reliably.
The concept of interconnected power systems is crucial for enhancing power system
stability, optimizing resource usage, minimizing generation cost, and ensuring energy security.
Concept of Interconnected Power System
In an interconnected system, the power plants are connected to a unified grid, allowing
electricity to flow from surplus regions to deficit areas. The central grid is managed by
transmission utilities that regulate power flows, balance loads, and maintain system
frequency and voltage.
An interconnected power system typically consists of:
Multiple generating stations (thermal, hydro, nuclear, solar, wind, etc.)
Transmission lines operating at high voltage (132kV, 220kV, 400kV, 765kV in India)
Substations and control centers
Load centers (industries, cities, rural areas)
Objectives and Benefits of Interconnection
1. 🔁 Load Sharing and Reliability
If one plant fails or shuts down for maintenance, others can supply the required load.
Reduces the risk of blackout or system collapse.
2. ⚡ Economic Operation
Base-load plants (like thermal or nuclear) can run at high efficiency, while peak loads
can be managed by hydro or gas-based stations.
Reduces the overall cost of generation.
3. 🌍 Resource Optimization
Different regions may have different resource advantages (e.g., hydro in the north-
east, solar in the west). Interconnection allows utilization of diverse resources.
4. 🧭 Grid Stability and Frequency Regulation
A larger grid can better absorb fluctuations in demand and generation.
Frequency deviations are managed more efficiently due to shared inertia.
5. 🔌 Facilitates Renewable Energy Integration
Since solar and wind are intermittent, interconnection helps in smoothing their
variability by pooling power from multiple sources.
6. 🤝 Regional Cooperation
Promotes cross-border energy trade and regional energy security (e.g., India exporting
electricity to Nepal, Bhutan, Bangladesh).
Interconnected System in India
India has a vast and integrated national grid managed by POSOCO (Power System Operation
Corporation). It is divided into five regional grids:
1. Northern Grid
2. Southern Grid
3. Eastern Grid
4. Western Grid
5. North-Eastern Grid
🔷 In 2013, all regional grids were synchronized into a single national grid operating at one
frequency (50 Hz). This makes India one of the largest synchronized grids in the world.
As of 2025, the total transmission line length exceeds 4.9 lakh circuit kilometers.
Inter-state and inter-regional transmission lines connect remote power plants to major
demand centers.
India also has international interconnections with Nepal, Bhutan, Bangladesh, and
Myanmar.
Example of Interconnected Generation
A hydropower plant in Himachal Pradesh may generate excess power during monsoon.
Through the national grid, this power can be transmitted to states like Maharashtra or
Tamil Nadu where demand is high.
During evenings, when solar output declines, thermal or gas plants in another region can
compensate for the shortfall.
Challenges in Interconnected Systems
1. Grid congestion due to limited transmission capacity.
2. Synchronization issues between different types of generation (renewable vs
conventional).
3. Need for advanced grid management systems (like SCADA, smart grid tech).
4. Risk of cascading failures if fault is not isolated quickly.
Recent Developments
Launch of the One Nation One Grid initiative.
Green Energy Corridor project to connect renewable-rich areas.
Deployment of high-voltage direct current (HVDC) lines for long-distance power transfer.
Use of real-time monitoring and AI-based grid control systems.
UNIT 2
1. Connected Load
Connected load refers to the total rated power of all electrical devices and appliances
connected to a consumer’s system, whether or not all are used simultaneously.
📝 Example:
If a house has 4 lights of 100 W each, 2 fans of 75 W, and a 1.5-ton AC of 1500 W, the
connected load is:
= (4 × 100) + (2 × 75) + 1500 = 400 + 150 + 1500 = 2050 W = 2.05 kW
🔹 Characteristics:
It is the theoretical maximum load a consumer can draw.
Used by utilities for planning service connections.
Often higher than actual usage, since all devices are rarely used at once.
🔹 Significance:
Helps in sizing cables, circuit breakers, and transformers.
Provides a baseline for maximum possible energy consumption.
2. Maximum Demand
🔹 Definition:
Maximum demand is the highest average load (in kW or MW) that a consumer or system
draws over a specified period (usually 15 or 30 minutes) during a billing cycle or season.
📝 Example:
If the highest average power drawn during any 30-minute period in a month is 1.6 kW, then
the maximum demand is 1.6 kW.
🔹 Characteristics:
It is a more realistic measure of power usage than connected load.
Varies by time of day, season, and consumer behavior.
Recorded using demand meters or maximum demand indicators.
🔹 Importance:
Power utilities use this value to design generation and transmission systems.
Consumers with high maximum demand are charged extra through "demand charges" in
tariffs.
3. Demand Factor
🔹 Definition:
Demand factor is the ratio of the maximum demand to the connected load.
Demand Factor=Maximum Demand/Connected Load
It is always less than or equal to 1.
Unitless (as both numerator and denominator are in kW or MW)
📝 Example:
If the connected load of a factory is 500 kW and its maximum demand is 300 kW,
Demand Factor=300/500=0.6
🔹 Significance:
Reflects the utilization of connected equipment.
A lower demand factor implies that many connected devices are unused or underused.
Used for economic sizing of equipment and avoiding overdesign.
🔹 Typical Values:
Residential buildings: 0.3 to 0.6
Commercial installations: 0.5 to 0.8
Industrial plants: 0.6 to 0.9
🔹 Typical Load Factor Ranges:
Type of Consumer Typical Load Factor
Residential 20–40%
Commercial 30–60%
Industrial 60–90%
3. Significance of Load Factor
The load factor plays a vital role in power system design and operation. Its significance can be
understood as follows:
🔹 1. Efficient Utilization of Infrastructure
A higher load factor means generation and transmission equipment are being used more
consistently.
Improves return on investment in power plants and grid infrastructure.
🔹 2. Lower Cost of Power Generation
Base-load plants (like thermal and nuclear) operate more economically when load factor
is high.
Reduces the need for expensive peak-load plants.
🔹 3. Tariff Design and Billing
Utilities encourage high load factors through lower tariffs or time-of-day pricing.
Encourages consumers to spread their usage more evenly throughout the day.
🔹 4. Environmental Benefits
Reduces frequent ramping up and down of generators.
Leads to lower fuel consumption and emissions.
🔹 5. Planning of Backup and Reserve Capacity
With a high load factor, less reserve margin is needed for fluctuating loads.
Helps in better scheduling and grid reliability.
📝 Summary:
Load Factor (%) Interpretation
< 40% Poor utilization (wasteful)
40–70% Moderate utilization
> 70% Efficient and desirable
🟠 Number of Units (in a Power Plant)
🔹 Definition:
The “Number of Units” refers to how many generating units (or boilers/turbines) are installed
in a power plant. Instead of a single large generator, power stations are usually built with
multiple units.
🔹 Objective:
To ensure flexibility, reliability, and continuity of power supply.
🔹 Factors Influencing Number of Units:
1. Total Installed Capacity
➤ Total capacity is divided into several identical or different units.
Example: For a 1000 MW power plant → 4 units of 250 MW each.
2. Load Variation
➤ Smaller units can be turned on/off to match load changes more efficiently.
3. Reliability
➤ If one unit fails, others continue working.
➤ Reduces complete shutdown risk.
4. Maintenance Scheduling
➤ Maintenance can be performed unit-wise without shutting down the entire station.
5. Grid Constraints
➤ Fewer large units may cause frequency and voltage fluctuations.
➤ More units provide better grid balancing.
🔹 Practical Example (India):
Super thermal stations like NTPC’s Dadri Plant may have 6–8 units of 200 MW or 500 MW
each.
🟠 Reserves in Power Systems
🔹 Definition:
Reserves are the additional generation capacity kept aside (but not always used) to meet
unexpected increases in demand or generation failures.
🔹 Types of Reserves:
1. Spinning Reserve
➤ Extra capacity available and running but not fully loaded.
➤ Can be brought online within seconds.
2. Cold Reserve
➤ Units that are shut down but can be started after some time (few hours to a day).
3. Hot Reserve
➤ Units kept in standby mode, warm and ready to supply power quickly.
4. Operating Reserve
➤ Sum of spinning + quick-start (hot) reserves.
5. Firm Reserve
➤ Long-term reserve kept to meet sudden future growth in demand.
🔹 Need for Reserves:
To maintain system reliability.
To handle sudden equipment failure or transmission line outage.
To meet unexpected demand surges (e.g., during heatwaves or events).
🔹 Typical Reserve Margins:
Power systems are planned with 15%–25% reserve margins over peak demand.
Example: If peak demand is 10,000 MW, system capacity is kept at ~12,000 MW.
—
🟠 3. Cost of Power Generation
🔹 Definition:
It is the total cost incurred in generating 1 unit (kWh) of electricity, including fixed, variable,
and capital costs.
🔹 Major Components of Cost:
1. Fixed Costs
➤ Independent of energy output.
➤ Includes salaries, interest on capital, maintenance, insurance.
2. Variable Costs
➤ Dependent on the amount of electricity generated.
➤ Includes fuel cost (coal, gas), lubricants, water usage.
3. Capital Cost
➤ Cost of land, building, equipment, installation.
➤ Spread over 20–30 years (life of the plant).
🔹 Fuel Cost (Most Influential):
Thermal plants: High fuel cost (coal/gas).
Hydropower: Almost zero fuel cost (only water usage).
Nuclear: Moderate fuel + high safety cost.
Renewable (solar/wind): No fuel cost, but high initial investment.
🟠 1. Depreciation in Power Systems
🔹 Definition:
Depreciation is the reduction in the value of physical assets of a power plant over time due
to wear and tear, aging, obsolescence, and usage. It reflects the cost of replacing the
equipment in the future and is considered a part of the fixed cost of power generation.
🔹 Why Depreciation Is Important:
Ensures sufficient funds are collected to replace old equipment at the end of its life.
Helps in realistic accounting and financial planning.
Affects tariff calculation and profitability.
🔹 Causes of Depreciation:
Physical wear and tear (e.g., in turbines, boilers).
Technological obsolescence (older machines become inefficient).
Natural aging and environmental factors (corrosion, temperature).
🔹 Common Methods of Calculating Depreciation:
1. Straight Line Method:
Depreciation is uniform every year.
1. Diminishing Balance Method:
Depreciation is calculated as a fixed percentage of the remaining value each year.
2. Sinking Fund Method:
A fixed amount is set aside annually and invested to replace the asset after its useful life.
🔹 Example:
A generator costs ₹10 crore, has a life of 20 years, and a salvage value of ₹1 crore:
Using straight-line method:
🔹 Application in Power Planning:
Incorporated into the total cost of power generation.
Affects tariff and pricing of electricity.
Helps utilities maintain financial health for future investments.
🟠 2. Tariff (Electricity Pricing)
🔹 Definition:
A tariff is the schedule of rates or prices charged by an electricity utility to consumers for the
energy supplied. It is designed to recover the cost of generation, transmission, and
distribution, while ensuring fair returns to the utility.
🔹 Objectives of a Good Tariff System:
Recover the total cost of power supply (fixed + variable).
Offer fairness to different categories of consumers.
Encourage efficient energy use and penalize wastage.
Attract investment and ensure long-term sustainability.
🔹 Components of Tariff:
1. Fixed Charge:
➤ Charged irrespective of energy used.
➤ Recovers fixed costs like salaries, maintenance, depreciation.
2. Energy Charge (Variable):
➤ Based on units (kWh) consumed.
➤ Recovers fuel and operating costs.
3. Demand Charge:
➤ Based on the maximum demand recorded (in kW/kVA).
➤ Helps recover infrastructure cost.
4. Fuel Adjustment Charge (FAC):
➤ Variable component adjusted based on fuel price fluctuations.
5. Subsidies and Surcharges:
➤ Government may subsidize agriculture or rural consumers.
➤ Higher tariffs for commercial or industrial users may cross-subsidize others.
🔹 Types of Tariffs:
Type Description
Simple Tariff Single flat rate per unit consumed. Easy to
understand.
Two-Part Tariff Includes fixed charge + energy charge.
Widely used in domestic sectors.
Three-Part Tariff Fixed charge + demand charge + energy
charge. Common in industrial use.
Time-of-Day Tariff (ToD) Higher rates during peak hours, lower
during off-peak. Encourages load shift.
Block Tariff Price per unit increases with consumption
(used in domestic billing).
🔹 Example of Domestic Tariff Slab (₹/kWh):
0–100 units → ₹3.50/unit
101–200 units → ₹4.50/unit
Above 200 units → ₹6.00/unit
🔹 Importance of Tariff Design:
Encourages energy conservation.
Recovers investment costs from consumers.
Provides transparency and accountability.
Affects affordability and accessibility of electricity.
Topic: Energy Management
—
🟠 1. Introduction
Energy management refers to the systematic process of monitoring, controlling, and
conserving energy in a building, industrial plant, or any organization. The goal is to reduce
energy consumption without compromising productivity, safety, or comfort. It plays a vital
role in cutting costs, improving efficiency, and reducing environmental impacts.
Energy management is not only a technical task—it also involves planning, decision-making,
and policy implementation.
🟠 2. Definition
Energy Management can be defined as:
“The judicious and effective use of energy to maximize profits and enhance competitive
positions through efficient energy use and cost savings.”
🟠 3. Objectives of Energy Management
1. Minimize energy waste and maximize efficient use.
2. Reduce energy costs and improve profitability.
3. Improve operating efficiency and system reliability.
4. Ensure compliance with government policies and standards.
5. Reduce environmental impact through lower emissions.
6. Encourage use of renewable and alternative energy sources.
🟠 4. Key Components of Energy Management
(A) Energy Planning
→ Assessing energy needs and setting realistic conservation goals.
(B) Energy Monitoring
→ Measuring current energy usage with instruments (kWh meters, flow meters, etc.).
(C) Energy Control
→ Implementing automatic systems (PLC, SCADA) to optimize usage in real time.
(D) Energy Auditing
→ Periodic analysis of energy flow in systems to identify wastage points and improvement
areas.
(E) Performance Analysis
→ Comparing actual consumption with benchmarks or historical data.
(F) Awareness and Training
→ Educating employees/workers about energy-saving behaviors and technologies.
🟠 5. Energy Management Process (Step-by-Step)
1. Conduct Energy Audit
➤ Identify where, how, and why energy is used.
2. Set Goals and Targets
➤ Define key performance indicators (KPIs), e.g., reduce consumption by 10%.
3. Develop Energy Strategy
➤ Create action plans for equipment upgrades, process changes, or renewable
integration.
4. Implement Solutions
➤ Install efficient motors, lighting systems, capacitors, automation, etc.
5. Monitor and Evaluate
➤ Use data analytics to track progress and fine-tune the strategy.
6. Continuous Improvement
➤ Update strategies based on feedback and technology upgrades.
🟠 6. Techniques Used in Energy Management
Technique Description
Demand Side Management (DSM) Optimizing electricity usage pattern during
peak hours
Load Scheduling Shifting energy-intensive processes to off-
peak hours
Power Factor Correction Installing capacitors to reduce reactive
power
Preventive Maintenance Regular servicing to improve equipment
efficiency
Energy Efficient Equipment Using appliances/motors with high star
ratings
Waste Heat Recovery Reusing exhaust heat in thermal or
industrial processes
🟢 7. Benefits of Energy Management
Area Benefits
Economic Cost savings through lower electricity bills
Technical Enhanced equipment life and reduced
breakdowns
Environmental Reduction in greenhouse gas emissions
Operational Improved reliability and reduced energy-
related downtimes
Strategic Competitive advantage and policy
compliance
Energy Audit – Detailed Theory
🟠 1. Introduction
An Energy Audit is a systematic process of analyzing energy flows in a building, process, or
system to understand how energy is used and to identify opportunities for energy
conservation and cost reduction. It helps in improving energy efficiency, reducing operational
costs, and minimizing environmental impact.
In simpler terms, it is like a financial audit — but instead of checking money flow, it checks
where and how energy is being consumed, lost, or wasted.
🟠 2. Objectives of Energy Audit
To identify areas of excessive energy consumption.
To assess the performance of existing energy systems.
To detect and quantify energy wastage or losses.
To recommend energy-saving measures and technologies.
To estimate cost savings and payback periods.
To create awareness about energy efficiency among staff and management.
🟠 3. Types of Energy Audit
There are typically three levels of energy audits based on the depth and scope of the
analysis:
1. Preliminary Audit (Walk-through Audit):
A quick assessment of energy consumption patterns.
Involves visual inspection and basic data collection.
Identifies obvious areas of energy wastage.
Less time-consuming and less detailed.
2. General (Mini) Energy Audit:
Involves limited data monitoring and some measurements.
Provides general recommendations for energy saving.
More detailed than preliminary audit but less exhaustive than detailed audit.
3. Detailed Energy Audit (DEA):
In-depth analysis of energy consumption with instrumentation.
Monitoring of key parameters like voltage, current, temperature, fuel flow, etc.
Includes cost-benefit analysis, ROI, and detailed action plans.
Most accurate and effective form of audit.
—
🟠 4. Methodology / Steps in Conducting an Energy Audit
1. Planning & Scope Definition:
Define the purpose, area, and goals of the audit.
Form a team and schedule the audit activities.
2. Data Collection:
Collect historical utility bills (electricity, fuel, water) for 12 months.
Survey equipment (motors, lighting, HVAC, boilers, etc.)
Record operating schedules, load factors, and consumption data.
3. Measurement & Monitoring:
Use energy meters, thermometers, flow meters, lux meters, etc.
Measure real-time data for electricity, heat, steam, compressed air, etc.
4. Analysis:
Compare actual energy usage with benchmarks or standards.
Identify areas with high specific energy consumption.
Perform energy balance and loss analysis.
5. Recommendations:
Suggest improvements: equipment replacement, automation, insulation, solar
integration, etc.
Estimate cost savings, investment cost, and payback period.
6. Report Preparation:
Prepare a formal report with findings, graphs, calculations, and recommendations.
Submit to management for implementation.
7. Follow-Up:
Monitor the implementation of suggested measures.
Conduct periodic audits for continuous improvement.
🟠 5. Areas Commonly Audited
Electrical systems (motors, pumps, compressors, lighting)
HVAC systems (air conditioning, ventilation, refrigeration)
Boilers and steam systems
Building insulation and design
Water heating and pumping
Renewable energy integration (solar, biomass)
🟠 6. Tools and Instruments Used
Power analyzer, energy meter
Thermocouple or infrared thermometer
Lux meter (for lighting audit)
Anemometer (for air flow measurement)
Flow meter (liquid/gas)
Tachometer (motor speed)
—
🟠 7. Benefits of Energy Audit
✅ Reduces energy bills and operating costs
✅ Improves process and system efficiency
✅ Extends equipment life
✅ Enhances environmental performance (less CO₂ emissions)
✅ Helps in regulatory compliance (like PAT scheme under BEE)
✅ Increases awareness and promotes energy culture in the organization
—
🟠 8. Real-life Example
In an industrial plant, a detailed energy audit revealed that 30% of compressed air was
leaking from old pipes. Fixing leaks and replacing inefficient compressors saved ₹5 lakhs per
year in electricity bills with a payback period of just 6 months.
Co-generation (Combined Heat and Power – CHP)
—
🟠 1. Introduction
Co-generation is a modern and highly efficient method of generating both electrical (or
mechanical) energy and useful thermal energy (heat or steam) from a single fuel source. This
dual production maximizes the energy output from fuel and reduces overall energy waste,
making it a vital part of energy conservation strategies in industries and large facilities.
Unlike conventional power generation where significant heat energy is wasted into the
environment, co-generation systems capture and utilize this waste heat for productive uses
such as heating, drying, or process steam.
🟠 2. Definition
Co-generation can be defined as:
❝ The simultaneous production of electrical (or mechanical) power and useful thermal energy
from a single source of fuel in an integrated system. ❞
It is also referred to as Combined Heat and Power (CHP) generation.
—
🟠 3. Principle of Co-generation
The basic principle of co-generation is to utilize the waste heat from electricity generation
that would otherwise be lost to the environment. In a typical power plant, only 30–35% of
fuel energy is converted into electricity, and the rest is lost as heat. Co-generation improves
overall energy efficiency up to 80–90% by capturing and using this thermal energy.
🟠 4. Block Diagram of a Co-generation Plant
🟩 (Text Description)
Fuel (Coal/Gas/Biomass) → Prime Mover (Gas Turbine/Steam Turbine/Engine)
↘ Electrical Generator (→ Electricity Supply)
↘ Heat Recovery System (→ Steam/Hot Water → Industrial Process/Heating)
🟠 5. Types of Co-generation Systems
Based on operating cycles and applications:
(A) Topping Cycle System:
⚙️ Fuel is first used to generate electricity, and the waste heat is used for thermal needs.
🟢 Most common type in industries.
(B) Bottoming Cycle System:
⚙️ Fuel is first used for a thermal process (like a furnace), and the waste heat is used to
generate electricity.
🟡 Used in energy-intensive processes like cement or steel plants.
(C) Combined Cycle Co-generation:
⚙️ Uses both gas and steam turbines in sequence for higher efficiency.
🔥 Gas turbine exhaust heat is used to produce steam for a steam turbine.
—
🟠 6. Fuels Used in Co-generation
Natural Gas
Biomass
Coal
Diesel
Industrial waste gases (in refineries, cement plants, etc.)
—
🟠 7. Applications of Co-generation
Sector Use of Co-generation
Industrial Plants Process steam + electricity (e.g., sugar,
textile, paper, cement)
Hospitals Heating, hot water, and electricity
Commercial Buildings Space heating + lighting power
District Heating Urban-scale heating through centralized
steam networks
Educational Campuses Combined heat and power for buildings
and labs
🟠 8. Advantages of Co-generation
✅ High Efficiency:
→ Overall efficiency up to 80–90% compared to ~35% in traditional plants.
✅ Reduced Fuel Consumption:
→ Saves primary energy due to combined use.
✅ Cost Savings:
→ Lower operating and fuel costs in the long run.
✅ Reduced Emissions:
→ Less CO₂ and other pollutants due to reduced fuel burning.
✅ Improved Reliability:
→ On-site power generation reduces dependency on grid supply.
✅ Energy Security:
→ Useful in remote or self-sufficient industrial units.
🟠 9. Disadvantages / Limitations
❌ High Initial Cost:
→ Equipment and setup can be expensive.
❌ Complex Design:
→ Needs detailed engineering and load matching.
❌ Limited Use for Small Loads:
→ Best suited for medium to large scale operations.
❌ Fuel Supply Dependency:
→ Availability and type of fuel affect performance and economics.
🟢 10. Conclusion
Co-generation is a powerful technique for increasing the overall efficiency of energy systems.
It plays a vital role in reducing energy consumption, operating costs, and environmental
impact, especially in energy-intensive sectors. With advancements in technology and
increasing emphasis on sustainability, co-generation is gaining popularity in industrial and
commercial applications worldwide.