0% found this document useful (0 votes)
7 views1 page

Polytropic Rak-Inverter en 2024

The document provides technical specifications for three models of a 3-phase heating system: RAK35 IVT, RAK45 IVT, and RAK90 IVT. It includes details on energy output, coefficient of performance (COP) in different modes (BOOST, SMART, ECO-Silence), noise levels, installation requirements, and dimensions. All models are classified as A according to EN 17645 and have varying performance metrics based on air and water temperatures.

Uploaded by

Burak kılıç
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
7 views1 page

Polytropic Rak-Inverter en 2024

The document provides technical specifications for three models of a 3-phase heating system: RAK35 IVT, RAK45 IVT, and RAK90 IVT. It includes details on energy output, coefficient of performance (COP) in different modes (BOOST, SMART, ECO-Silence), noise levels, installation requirements, and dimensions. All models are classified as A according to EN 17645 and have varying performance metrics based on air and water temperatures.

Uploaded by

Burak kılıç
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Technical specifications

3-PHASE MODEL RAK35 IVT RAK45 IVT RAK90 IVT

SCOP according to EN 17645 7,1 7,1 7,2

Classification according to EN 17645 A A A

Air 26°C / Water 26°C / Humidity 80%

Energy Output BOOST mode 41,5 kW 56,8 kW 110,0 kW

COP BOOST mode 6,1 5,6 6,0

Energy Output SMART mode 41,5 ~ 24,1 kW 56,8 ~ 24,4 kW 110,0 ~ 39,1 kW

COP SMART mode 6,1 ~ 10,2 5,6 ~ 10,2 6,0 ~ 10,1

Energy output ECO-Silence mode 24,1 kW 24,4 kW 39,1 kW

COP ECO-Silence mode 10,2 10,2 10,1

Air 15°C / Water 26°C / Humidity 70%*

Energy Output BOOST mode 35,6 kW 43,7 kW 85,6 kW

COP BOOST mode 4,6 4,4 4,5

Energy Output SMART mode 35,6 ~ 18,0 kW 43,7 ~ 18,2 kW 85,6 ~ 31,9 kW

COP SMART mode 4,6 ~ 7,2 4,4 ~ 7,1 4,5 ~ 6,5

Energy output ECO-Silence mode 18,0 kW 18,2 kW 31,9 kW

COP ECO-Silence mode 7,2 7,1 6,5

Air 7°C / Water 26°C / Humidity 90%

Energy Output BOOST mode 28,5 kW 32,9 kW 63,7 kW

COP BOOST mode 3,7 3,4 3,2

Air -7°C / Water 26°C / Humidity 0%

Energy Output BOOST mode 17,8 kW 21,9 kW 40,4 kW

COP BOOST mode 2,8 2,7 2,4

Noise level CTTM mini-maxi (at 10m)


46 ~ 49 dB(A) 46 ~ 51 dB(A) -
according to EN ISO 3741 : 2010 **

Maximum noise level (at 10m)


39 dB(A) 44 dB(A) 49 dB(A)
according to EN ISO 3744: 2010

Temperature working range -15°C -> 43°C

Installation

Hydraulic connexions D. 63 mm 90 mm flanges + counter-flanges

Power 400 V / 3~+N / 50 Hz

Circuit breaker and cable size 3P +N C 25 A 3P +N C 32 A 3P +N C 50 A


(for 20 m) (5G*4 mm²) (5G*6 mm²) (5G*10 mm²)

Power input Max (air 26°C) 6,8 kW 10,1 kW 18,0 kW

Minimum water flow 12 m³/h 15 m³/h 40 m³/h

Dimensions in mm (L x l x h) 1050 x 1050 x 1260 2144 x 1113 x 1260

Weight net (gross) 207 kg (264 kg) 410 kg (450 kg)

* May to September with cover.


** Tests carried out at an air temperature of 15°C, with a water inlet at 26°C and a water outlet at 28°C to define the water flow rate, heating capacity and consumption, in
accordance with FPP recommendations.