Technical specifications
3-PHASE MODEL RAK35 IVT RAK45 IVT RAK90 IVT
SCOP according to EN 17645 7,1 7,1 7,2
Classification according to EN 17645 A A A
Air 26°C / Water 26°C / Humidity 80%
Energy Output BOOST mode 41,5 kW 56,8 kW 110,0 kW
COP BOOST mode 6,1 5,6 6,0
Energy Output SMART mode 41,5 ~ 24,1 kW 56,8 ~ 24,4 kW 110,0 ~ 39,1 kW
COP SMART mode 6,1 ~ 10,2 5,6 ~ 10,2 6,0 ~ 10,1
Energy output ECO-Silence mode 24,1 kW 24,4 kW 39,1 kW
COP ECO-Silence mode 10,2 10,2 10,1
Air 15°C / Water 26°C / Humidity 70%*
Energy Output BOOST mode 35,6 kW 43,7 kW 85,6 kW
COP BOOST mode 4,6 4,4 4,5
Energy Output SMART mode 35,6 ~ 18,0 kW 43,7 ~ 18,2 kW 85,6 ~ 31,9 kW
COP SMART mode 4,6 ~ 7,2 4,4 ~ 7,1 4,5 ~ 6,5
Energy output ECO-Silence mode 18,0 kW 18,2 kW 31,9 kW
COP ECO-Silence mode 7,2 7,1 6,5
Air 7°C / Water 26°C / Humidity 90%
Energy Output BOOST mode 28,5 kW 32,9 kW 63,7 kW
COP BOOST mode 3,7 3,4 3,2
Air -7°C / Water 26°C / Humidity 0%
Energy Output BOOST mode 17,8 kW 21,9 kW 40,4 kW
COP BOOST mode 2,8 2,7 2,4
Noise level CTTM mini-maxi (at 10m)
46 ~ 49 dB(A) 46 ~ 51 dB(A) -
according to EN ISO 3741 : 2010 **
Maximum noise level (at 10m)
39 dB(A) 44 dB(A) 49 dB(A)
according to EN ISO 3744: 2010
Temperature working range -15°C -> 43°C
Installation
Hydraulic connexions D. 63 mm 90 mm flanges + counter-flanges
Power 400 V / 3~+N / 50 Hz
Circuit breaker and cable size 3P +N C 25 A 3P +N C 32 A 3P +N C 50 A
(for 20 m) (5G*4 mm²) (5G*6 mm²) (5G*10 mm²)
Power input Max (air 26°C) 6,8 kW 10,1 kW 18,0 kW
Minimum water flow 12 m³/h 15 m³/h 40 m³/h
Dimensions in mm (L x l x h) 1050 x 1050 x 1260 2144 x 1113 x 1260
Weight net (gross) 207 kg (264 kg) 410 kg (450 kg)
* May to September with cover.
** Tests carried out at an air temperature of 15°C, with a water inlet at 26°C and a water outlet at 28°C to define the water flow rate, heating capacity and consumption, in
accordance with FPP recommendations.
*** Noise levels in BOOST and ECO mode at 10 m, certified by the independent laboratory Centre de Transfert de Technologie du Mans, in accordance with EN ISO 3741: 2010