Sensitive #
ENT RESOLUTION SHEET (CRS)
Project Name: King Salman International Airport - (SO&W)
Project Number: 0010
Client: King Salman International Airport Development Company
Contract Number: C00063
Reference Document Number, Submission Title & Revision: SF00100039008C-C00063-DOV-XX-MAT-ME-000002-MAR - UPVC Pipe and Fittings - Rev01
CRS Document Number & Revision: SF00100039008C-C00063-DOV-XX-CRS-ME-000010 Rev01
Date of Review: 9/7/2025 Issue Date: 9/3/2025
ASSESSMENT CODES:
OVERALL DISCIPLINE CODE
The following document(s) has/have been reviewed by the
Client/the Client's representative(s) at the Consultant / A - Accepted.
B - Accepted with Comments.
Contractor's request and are returned with the following
Observations & Comments for necessary action
C - Revise and Resubmit. A
D - Rejected.
I - For Information Only. (This is a note only, does not require a response / action)
Comment's Reviewer
Reference Number of Document or Document Doc. Responder's Sign-Off
S/N Reviewer's Name Reviewer's Company Workflow No. Document Name Source - Page/ Reviewer's Comments Assessed Originator Response Reference
Drawing Discipline Rev. Name/Company (Open/ Closed)
Section Code
SF00100039008C-C00063-DOV-XX-MAT-ME- MAR - UPVC Pipe and Fittings -
1 Soundra Murugesan PDP WF-006510 ME 1
000002-MAR Rev01 The current submittal covers UPVC pipes
and fittings (50–125 mm) for wastewater
network inside the building only. If the
scope includes external/underground
drainage works (e.g., external sewer
connections, manholes, underground
networks), then larger diameters (160 mm,
The current submittal only covers for
SF00100039008C-C00063-DOV-XX-MAT-ME- MAR - UPVC Pipe and Fittings - 200 mm, 250 mm, etc.) and alternative
2 Soundra Murugesan PDP WF-006510 ME 1 MAR Form B 200mm for infrastructure for gravity line
000002-MAR Rev01 materials such as HDPE or GRP may be
drainage
required. Please clarify whether these are
excluded from this package. For
completeness and to avoid ambiguity, it is
recommended to provide a clear matrix
indicating application vs. pipe size vs.
material (e.g., UPVC for internal drainage,
HDPE/GRP for external underground).
The sheet mentions “CPVC Pipe and
2.Specification
SF00100039008C-C00063-DOV-XX-MAT-ME- MAR - UPVC Pipe and Fittings - Fittings” in the header, while the request is
3 Soundra Murugesan PDP WF-006510 ME 1 Comparison and B Changed to UPVC
000002-MAR Rev01 for UPVC. This should be corrected for
Compliance Sheet
consistency.
The compliance sheet does not provide
clause-by-clause verification against SBC
701 and other referenced standards.
General “Yes” responses are insufficient.
Please revise the compliance sheet to
2.Specification
SF00100039008C-C00063-DOV-XX-MAT-ME- MAR - UPVC Pipe and Fittings - include specific SBC 701 clause references The compliance sheet have been made with
4 Soundra Murugesan PDP WF-006510 ME 1 Comparison and C
000002-MAR Rev01 and provide clause-by-clause compliance refrence to SBC 702.
Compliance Sheet
statements with supporting test report
references instead of general ‘Yes’ remarks.
This will make the compliance verification
clearer and acceptable to the
consultant/client.
3. Approval and Parts of the text are scanned OCR errors
SF00100039008C-C00063-DOV-XX-MAT-ME- MAR - UPVC Pipe and Fittings - Profile of (e.g., random symbols). Recommend
5 Soundra Murugesan PDP WF-006510 ME 1 B cleared
000002-MAR Rev01 Manufacturer / cleaning and reformatting for readability
Supplier before submission to client.
Ensure that test figures and tables (e.g.,
4. Product
tensile vs temperature, joint dimensions)
SF00100039008C-C00063-DOV-XX-MAT-ME- MAR - UPVC Pipe and Fittings - Catalogue and
6 Soundra Murugesan PDP WF-006510 ME 1 are clearly formatted and legible. Some B relevant have been made clear
000002-MAR Rev01 Technical Data
tables appear cluttered and may need
Sheet
clearer formatting.
Ensure cross-references to contract
SF00100039008C-C00063-DOV-XX-MAT-ME- MAR - UPVC Pipe and Fittings - 5. Reference
7 Soundra Murugesan PDP WF-006510 ME 1 specification clauses are consistent and B Clause number and refrence code added
000002-MAR Rev01 Specification
page/section numbers are properly cited.
It would be clearer to indicate whether
these materials are applicable for
underground drainage or limited to above-
SF00100039008C-C00063-DOV-XX-MAT-ME- MAR - UPVC Pipe and Fittings - 6. Area of ground internal systems. Instead of
8 Soundra Murugesan PDP WF-006510 ME 1 B It is for the underground drainage
000002-MAR Rev01 Application attaching the entire drawing, consider
providing a simple table (Inside / Outside /
Underground / Above-ground) to summarize
applicability.
Recommend highlighting key test results
SF00100039008C-C00063-DOV-XX-MAT-ME- MAR - UPVC Pipe and Fittings - summaries in a table (pass/fail) for easier
9 Soundra Murugesan PDP WF-006510 ME 1 7. Test Report B Supplier doesnot have the format
000002-MAR Rev01 review, instead of only attaching raw
reports.
Ensure all certificates are valid (check
SF00100039008C-C00063-DOV-XX-MAT-ME- MAR - UPVC Pipe and Fittings - 8. Quality
10 Soundra Murugesan PDP WF-006510 ME 1 expiry dates) and attach copies in high- B supplier will provide with MIR
000002-MAR Rev01 Certificates
resolution for client records.
Recommend shortlisting only most
9. Previous
SF00100039008C-C00063-DOV-XX-MAT-ME- MAR - UPVC Pipe and Fittings - relevant/ comparable projects (e.g., with
11 Soundra Murugesan PDP WF-006510 ME 1 Approvals / List of B same approvals to ensure Supplier history
000002-MAR Rev01 similar application in wastewater networks)
Projects
for conciseness.
Specify duration of warranty (in years) and
SF00100039008C-C00063-DOV-XX-MAT-ME- MAR - UPVC Pipe and Fittings - whether it covers material replacement,
12 Soundra Murugesan PDP WF-006510 ME 1 10. Warranties B Warranty will be provided in MIR for 5 years
000002-MAR Rev01 installation defects, or both inline with the
Contract Requirements.
DM99930182000M-C00029-MSE-XX-TEM-PC-000001-03 1 of 2
# Classification - Public
Sensitive #
DM99930182000M-C00029-MSE-XX-TEM-PC-000001-03 2 of 2
# Classification - Public