CDS CS Instrument-Support C.01.10-U3
CDS CS Instrument-Support C.01.10-U3
Supported Instruments
Notices
Manual Part Number Warranty Safety Notices
M8301-90059 Rev. B The material contained in this CAUTION
Edition 05/2020 document is provided “as is,” and is
subject to being changed, without A CAUTION notice denotes a hazard. It
notice, in future editions. Further, to the calls attention to an operating
Copyright maximum extent permitted by procedure, practice, or the like that, if
© Agilent Technologies, Inc. 2010-2019, applicable law, Agilent disclaims all not correctly performed or adhered to,
2020 warranties, either express or implied,
with regard to this manual and any could result in damage to the product
No part of this manual may be information contained herein, including or loss of important data. Do not
reproduced in any form or by any but not limited to the implied warranties
means (including electronic storage proceed beyond a CAUTION notice until
of merchantability and fitness for a
and retrieval or translation into a foreign particular purpose. Agilent shall not be the indicated conditions are fully
language) without prior agreement and liable for errors or for incidental or understood and met.
written consent from Agilent consequential damages in connection
Technologies, Inc. as governed by with the furnishing, use, or performance
United States and international of this document or of any information
WARNING
copyright laws. contained herein. Should Agilent and
A WARNING notice denotes a hazard.
the user have a separate written
agreement with warranty terms It calls attention to an operating
Agilent Technologies, Inc. covering the material in this document procedure, practice, or the like that, if
5301 Stevens Creek Blvd. that conflict with these terms, the
Santa Clara, CA 95051 not correctly performed or adhered to,
warranty terms in the separate could result in personal injury or death.
USA agreement shall control.
Do not proceed beyond a WARNING
Technology Licenses notice until the indicated conditions
Software Revision The hardware and/or software
are fully understood and met.
This guide is valid for the C.01.10 described in this document are
revision update 3 or higher of Agilent furnished under a license and may be
OpenLab CDS ChemStation Edition, used or copied only in accordance with
until superseded. the terms of such license.
Operating Systems
All instrument drivers are supported on the following OS unless otherwise noted
Windows 7 SP1 Enterprise and Professional (64-bit)
Windows 10 Enterprise and Professional (64-bit)
For more detail and support information on server operating systems, please see
OpenLab CDS ChemStation Edition Requirements guide.
Agilent OpenLab CDS drivers are based on the RC.Net architecture. Information in
this guide refers to this driver type, unless otherwise noted.
RC.Net interface version 3.2.1 is integrated with this version of ChemStation.
For single quad Mass Spectrometer, only “Classic Plus” drivers are available with
OpenLab CDS ChemStation Edition. The Classic Plus driver types can be combined
with RC.Net drivers via their CIC ports.
The following Agilent instrument driver software revisions are part of the OpenLab
CDS ChemStation C.01.10 software package and are installed with the software:
Table 1 Driver Revisions provided with OpenLab CDS ChemStation C.01.10 update 3
RC.Net Instrument Driver Driver Software Revision
Agilent LC 3.2
Agilent ELSD 1.8
Agilent GC 3.2
Agilent Micro GC 2.1.3
Agilent 35900E A/D Converter 2.3
If you are looking for information on the build number of the included drivers, please
refer to Driver Revisions, accessible from the Resource Platform > Administration >
Configuration.
Firmware Revisions
Agilent recommends using the most recent firmware revisions to provide the
highest level of system capability.
Agilent and other vendors may release RC.net drivers independent of the OpenLab
CDS ChemStation Edition releases. Agilent driver software is forward compatible
regarding firmware, i.e. the firmware can be updated without the need of updating
the driver or CDS.
LC Instruments:
In the menu, go to Instrument > Revisions & Serial #s
GC Instruments:
1 In the menu, go to Instrument > Instrument Configuration.
2 Select the GC instrument under Selected modules,
3 Click the configure button, then select the configuration tab.
J4100A Jet Direct Card and 82357B USB /GPIB interface are not compatible with
the current version of OpenLab CDS ChemStation
GPIB Compatibility
OpenLab CDS ChemStation Edition can control all Agilent LC modules in support
using LC driver release 3.0 or higher.
The tables in this chapter list the supported LC modules. Please note that using
some driver features require current firmware versions such as valve-thermostat
clusters or new temperature control modes.
Agilent recommends using current LC firmware sets with your OpenLab CDS
ChemStation Edition.
The latest LC firmware sets are 7.01, 6.50, and 6.30.
Some of the modules are supported with firmware revisions lower than the ones
available in the current firmware set. Please see the respective Release Note for
Agilent LC and CE drivers for more information.
NOTE LC and CE firmware revisions are grouped into sets for each module or system.
Firmware sets include just the latest firmware of each module.
Modules of one LC instrument always need to have firmware from the same set.
Firmware of one set is fully compatible with your CDS that supports this firmware
set. However, if one module uses an older firmware revision newly added
functionality might not be supported.
Do not mix firmware revisions from one set with older or newer sets. Firmware is
not tested across set borders!
Please visit the Agilent site LC Firmware News and Downloads to download the
latest Agilent LC firmware.
Firmware Set 7.01 can be downloaded from http://www.agilent.com/en-
us/firmwareDownload?whid=99818.
For more information, please see the respective LC driver release notes. The
Release Notes for Agilent LC and CE drivers (ReleaseNotes_Driver_LC-CE.pdf) is
available on your software media.
You only need to upgrade ALL existing modules if
A new LC module is added to the existing system (recommended)
One of the existing modules requires an upgrade due to a bug fix solved with
the latest release.
Please note that the LC Driver releases are independent from CDS Releases.
The listed Agilent LC modules are supported to be controlled with OpenLab CDS
ChemStation Edition unless stated otherwise. Only RC.net drivers are supported,
unless stated otherwise.
The Agilent LC-drivers are backwards compatible. Modules with identical product
numbers are supported, even if the tables below list only the name of the current
model version. 1100 Series models are supported on a best effort basis only.
For details, please see the driver Release Notes of the driver revision you are using.
Product
Module Name Comment
Number
G1313A 1100 Series Autosampler Best effort
G1329A 1200 Series Standard Autosampler
G1329B 1260 Infinity Standard Autosampler
G1367A 1100 Series Well-Plate Sampler Best effort
G1367B 1200 Series High Performance Autosampler
G1367C 1200 Series High Performance Autosampler SL
G1367D 1200 Series High Performance Autosampler SL+
G1367E 1260 Infinity High Performance Autosampler
G1368A Thermostatted Well plate sampler
G1377A 1260 Infinity High Performance Micro Autosampler
G1389A 1100 Micro-Scale Autosampler Best effort
G2258A 1260 Infinity Dual-Loop Autosampler
G2260A 1260 Infinity Preparative Autosampler (High flow)
G4226A 1290 Infinity Autosampler
G4303A 1260 Infinity SFC Standard Autosampler
Product
Module Name Comment
Number
G4767A 1260 Infinity II SFC Multisampler
G5667A 1260 Infinity Bio-Inert High-Performance Autosampler
G5668A 1260 Infinity II Bio-Inert Multisampler
G7129A 1260 Infinity II Vialsampler
G7129B 1290 Infinity II Vialsampler
G7129C 1260 Infinity II Vialsampler
G7157A 1260 Infinity II Preparative Autosampler
Requires LC driver 3.1, and
ChemStation C.01.10 update 2
or higher.
G7158B 1290 Infinity II Open-bed Sampler / Collector
Instrument configuration shows
two modules: G7169B (injector)
and G7159B (fraction collector)
G7167A 1260 Infinity II Multisampler
G7167B 1290 Infinity II Multisampler
Agilent LC – Pumps
Product
Module Name Comment
Number
G1310A 1200 Series Isocratic Pump
G1310B 1260 Infinity Isocratic Pump
G1311A 1200 Series Quaternary Pump 1
G1311B 1260 Infinity Quaternary Pump 1
G1311C 1260 Infinity Quaternary Pump VL 1
G1312A 1260 Infinity Binary Pump 1
G1312B 1260 Infinity Binary Pump SL1
G1312C 1260 Infinity Binary Pump VL1
G1361A 1260 Infinity Preparative Pump
G1376A 1260 Infinity Capillary Pump
G2226A 1260 Infinity Nanoflow Pump
G4204A 1290 Quaternary Pump 1
G4220A 1290 Infinity Binary Pump 1
G4220B 1290 Infinity Binary Pump VL 1
G4302A 1260 Infinity SFC Binary Pump 1
G4782A 1260 Infinity II SFC Binary Pump
1 Pump valve clusters are possible for marked pumps with up to 2 valves of type G1160A and/or G1170A
Product
Module Name Comment
Number
G7120A 1290 Infinity II High Speed Pump
Agilent LC – Detectors
Product
Module Name Comment
Number
VWD
G1314A 1100 Series Variable Wavelength Detector
G1314B 1260 Infinity Variable Wavelength Detector VL
Product
Module Name Comment
Number
G1314C 1260 Infinity Variable Wavelength Detector VL+
G1314D 1200 Series Variable Wavelength Detector
G1314E 1290 Infinity Variable Wavelength Detector
G1314F 1260 Infinity Variable Wavelength Detector
G7114A 1260 Infinity II Variable Wavelength Detector
G7114B 1290 Infinity II Variable Wavelength Detector
MWD
G1365A 1100 Series Multiple Wavelength Detector Best effort
G1365B 1200 Series Multiple Wavelength Detector
G1365C 1260 Infinity Multiple Wavelength Detector
G1365D 1260 Infinity Multiple Wavelength Detector VL
G7165A 1260 Infinity II Multiple Wavelength Detector
FLD
G1321A 1100 / 1200 Fluorescence Detector
G1321B 1260 Infinity Fluorescence Detector Spectra
G1321C 1260 Infinity Fluorescence Detector
G7121A 1260 Infinity II Fluorescence Detector
G7121B 1260 Infinity II Fluorescence Detector Spectra
DAD
G1315A 1100 Series Diode Array Detector
G1315B 1200 Series Diode Array Detector
G1315C 1200 Series Diode Array Detector VL+
G1315D 1200 Series Diode Array Detector VL
G4212A 1290 Infinity Diode Array Detector
G4212B 1260 Infinity Diode Array Detector
Product
Module Name Comment
Number
G4212A/B 2x G4212A or 2x G4212B or a combination of 1x G4212A and 1x No add-on software
HDR-DAD G4212B required.
Cluster HDR function included
in RC.net drivers
G7115A 1260 Infinity II Diode Array Detector WR
G7117A 1290 Infinity II Diode Array Detector FS
G7117B 1290 Infinity II Diode Array Detector
G7117C 1260 Infinity II Diode Array Detector HS
G7117A/B 2x G7117A or 2x G7117B or a combination of 1x G7117A and 1x No add-on software
HDR-DAD G7117B required. HDR
Cluster function included in
RC.net drivers
RID
G1362A 1100/1200 Infinity Refractive Index Detector
G7162A 1260 Infinity II Refractive Index Detector
G7162B 1290 Infinity II Refractive Index Detector
ELSD
G4218A 1260 Infinity Evaporative Light Scattering Detector Not supported
G4260A 1260 Infinity 380 Evaporative Light Scattering Detector NOT localized for
Japanese and
G4261A 1290 Infinity 385 Evaporative Light Scattering Detector Chinese ChemStation
G4260B 1260 Infinity II Evaporative Light Scattering Detector RS232, not supported
G4261B 1290 Infinity Evaporative Light Scattering Detector on AIC.
Product
Module Name Comment
Number
G5664A 1260 Infinity Bio-Inert Fraction Collector
G5664B 1260 II Infinity Bio-Inert Fraction Collector
G7159B 1290 Infinity II Preparative Open-Bed Fraction Collector
G7166A 1260 Infinity II Preparative Valve-Based Fraction Collector
Fraction Any combination of up to three G1364A/B/C or G5664A plus a fourth G1364A/B/C or
Collector G5664A for recovery can be clustered.
Cluster controlling multiple un-clustered Fraction Collectors is not supported.
G1364 E /F can be clustered with a G7166A or the same module type for recovery
collection.
G7159 can be clustered with a G7166A for recovery
Product
Module Name Communication Comment
Number
Agilent 410 Autosampler RS232 Not supported
Agilent 440 Fraction Collector RS232 Not supported
Product
Module Name Comment
Number
G4293C 1220 Infinity LC System VL, Gradient, ALS, VWD, 400 bar
G4294B 1220 LC Infinity Gradient System
Single Quadrupole Modules listed in the table below are supported, unless
stated otherwise.
Product
Module Name Comment
Number
G6110A 6100 Series Single Quadrupole LC/MS System
G6120A
G6130A
G6140A
G6120B 6100 Series Single Quadrupole LC/MS System
G6125B LC/MSD
G6130B 6100 Series Single Quadrupole LC/MS System
G6135B LC/MSD XT
G6150B 6100 Series Single Quadrupole LC/MS System
G6120C 6100 Series Single Quadrupole LC/MS System
Not supported.
G6130C 6100 Series Single Quadrupole LC/MS System
OpenLab CDS version 2.x
G6125C LC/MSD only
G6135C LC/MSD XT
G6160A LC/MSD iQ Single Quadrupole LC/MS System Not supported. OpenLab
CDS version 2.3 or higher.
LC Single-Quad Sources
G1947A APCI LC SQ Source Not supported
G1947B APCI LC SQ Source
G1971A APPI LC SQ Source Not supported
G1971B APPI LC SQ Source
G1948A ESI LC SQ Source Not supported
Product
Module Name Comment
Number
G1948B ESI LC SQ Source
G1978B Multimode Source
G4240A Chip Cube Interface Not supported
G1968C Active Splitter Kit supported on English
ChemStation only
CTC Autosampler Classic Driver only.
Releases B.01.01 or later are
NOT compatible with the
Cycle Composer software
from CTC. Cannot co-reside
Not supported on Japanese
and Chinese ChemStation
G1979A SIDEBox Not supported
G1958B Agilent Jet Stream for Single Quad
G1951A Analog Output Accessory
NOTE When OpenLab CDS ChemStation Edition is used to control an Agilent 3D Capillary
Electrophoresis system, no additional instruments are supported on the PC system.
When OpenLab CDS ChemStation Edition is used to control the Agilent LC/MS, in
conjunction with the Agilent 3D Capillary Electrophoresis system, no additional
instruments are supported on the PC system (the one PC controls only the CE and
MS system).
CE/MS systems are supported with OpenLab CDS ChemStation Edition when
configured as CE/MS system, workstation, and networked workstation only. Co-
installation is possible, but no Co-execution.
35900E Supported
35900E Series II
Other
NOTE Communication is handled via LAN. GCs using GPIB must update to LAN.
Agilent GC support
Product
Module Name Comment
Number
G3950A Intuvo 9000 GC system Supported
G3952A 7683 ALS family not supported
G3953A
G3540A 8890 Series GC System Supported
G3542A
G3543A
G3545A
Product
Module Name Comment
Number
G2629A 6850 handheld Controller Not Supported
G2630A Supported
G2630B
Other
Product Module Name Comment
Number
G1176A, 6820 GC Not Supported
G1180A
5890A Not Supported
Other
Product
Model Name Comment
Number
19405A Sampler Event Control Module (SECM) Not supported
G7360A Archon Purge and Trap Auto sampler for Water only Not supported
G7361A Archon Purge and Trap Auto sampler for Needle Sparge Not supported
NOTE License number no longer required for installation. The software registration packet
will still include a license number.
Product
Model Name Comment
Number
G1289B, 7694B Not supported
G1290B, 7694E Headspace
G1883A
G4556A, 7697A Headspace Supported,
G4557A
G1888A G1888 Headspace Supported
Product
Model Name Comment
Number
Supported
G6501B,
Agilent PAL-xt PAL-xt method parameters are available
G6502B,
CTC Sampler to Intelligent Reporting beginning in PAL Software
G6509B
Rev. B.01.07.
G7366A,
G7367A, Agilent PAL-3
Supported.
G7368A, CTC Autosampler
G7370A
For further information please consult the respective driver user- and
service documentation, your local Agilent sales representative or check into
SubscribeNet.
Overview
GC instrument
Configure your GC instrument with instrument type Agilent GC Core
System (VL). The appropriate instrument drivers are bundled with the
instrument hardware.
With exception of the MSD drivers, classic drivers are not supported with
ChemStation C.01.10.
For information how to reconfigure instruments with classic drivers to use
RC.net drivers please see the OpenLab CDS ChemStation Edition
Configuration Guide, Chapter 5, section “Convert Classic Instrument
Drivers to RC.NET” (CDS_CS_Concepts.pdf).
www.agilent.com
© Agilent Technologies, Inc. 2010- 2019, 2020
Edition 05/2020
M8301-90059 Rev. B