0% found this document useful (0 votes)
6 views2 pages

Mikro - Apfc PFR-140-120-80-60

The document provides specifications and features of the PFR140 Power Factor Regulator, which includes microprocessor-based control, automatic adjustments, and alarms for various conditions. It outlines technical data such as environmental conditions, control range, output contacts, and mechanical details. Additionally, it lists various models available for different auxiliary voltages and frequencies.

Uploaded by

Mai Văn Bách
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
6 views2 pages

Mikro - Apfc PFR-140-120-80-60

The document provides specifications and features of the PFR140 Power Factor Regulator, which includes microprocessor-based control, automatic adjustments, and alarms for various conditions. It outlines technical data such as environmental conditions, control range, output contacts, and mechanical details. Additionally, it lists various models available for different auxiliary voltages and frequencies.

Uploaded by

Mai Văn Bách
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Power Factor Regulator

www.itmikro.com

PFR140
120
80
60
Features
• Microprocessor based intelligent auto switching
control
• Automatic C/K and rated step adjustment
• Automatic CT polarity correction
• Display of power factor, current & total harmonic
distortion of current
• Programmable sensitivity
• Last step can be used as alarm/fan output
• Under/over voltage alarm, under/over compensate
alarm & high harmonic distortion alarm
• User-friendly setting
• Complies with IEC 61000-6-2 standard

Technical Data
ENVIRONMENTAL CONDITIONS
RATINGS AUXILIARY POWER SUPPLY CURRENT INPUT Temperature : -10°C to 55°C
Current Supply voltage : 220~240 V AC / Rated current ( In ) :5A Humidity : 5% to 95%,
380~415 V AC Operating Limits : 0.05 A to 6.5 A non-condensing
Operating Limits : -15% + 10% Rated Frequency : 50 Hz or 60 Hz
Consumption : 10 VA max
Rated frequency : 50 Hz or 60 Hz MECHANICAL
m

CONTROL RANGE Mounting : Panel mounting


PFR 140 / 120 / 80 / 60

Power factor setting : 0.8 Ind - 0.8 Cap Dimension (mm) : 144(w) x 144(h) x 90(d)
co

OUTPUT CONTACTS C/K setting : 0.03 - 1.20 / Automatic Enclosure protection : IP54 at the panel
Numbers of outputs : 6 / 8 / 12 / 14 Switching sensitivity : 5 - 600 s/step Approximate weight : 1.2 kg
(PFR60/PFR80 Reconnection time for
u.

/PFR120/PFR140 ) same step : 5 - 240 s


Rated voltage : 250 V AC THD threshold : 0.20 - 3.00 ( 20% -
ia

Contact rating :5 A 300% ) / OFF


Expected electrical life : 100,000 operations Switching Program : Automatic / Automatic
ha

at rated current Rotate / 4-quadrant /


Expected mechanical life : 5 x 106 operations Manual
en

Max current for the Rated step coefficient : 0 / 1 / 2 / 3 / 4 / 5 / 6 /


common terminals : 12 A continuous 8 / 12 / 16
( Automatic if C/K set
di

to Auto )
Co
Power Factor Regulator

www.itmikro.com

Typical Application Diagram

Case Dimensions Ordering Information


MODEL DESCRIPTION
PFR60 - 415 - 50 6 Steps, 50 Hz system, auxiliary voltage 380~415 V AC

PFR80 - 415 - 50 8 Steps, 50 Hz system, auxiliary voltage 380~415 V AC

PFR120 - 415 - 50 12 Steps, 50 Hz system, auxiliary voltage 380~415 V AC

PFR140 - 415 - 50 14 Steps, 50 Hz system, auxiliary voltage 380~415 V AC

PFR60 - 220 - 50 6 Steps, 50 Hz system, auxiliary voltage 220~240 V AC

PFR80 - 220 - 50 8 Steps, 50 Hz system, auxiliary voltage 220~240 V AC

PFR120 - 220 - 50 12 Steps, 50 Hz system, auxiliary voltage 220~240 V AC

PFR140 - 220 - 50 14 Steps, 50 Hz system, auxiliary voltage 220~240 V AC


m

PFR60 - 415 - 60 6 Steps, 60 Hz system, auxiliary voltage 380~415 V AC


PFR 140 / 120 / 80 / 60

co

PFR80 - 415 - 60 8 Steps, 60 Hz system, auxiliary voltage 380~415 V AC


u.

PFR120 - 415 - 60 12 Steps, 60 Hz system, auxiliary voltage 380~415 V AC


ia

PFR140 - 415 - 60 14 Steps, 60 Hz system, auxiliary voltage 380~415 V AC

PFR60 - 220 - 60 6 Steps, 60 Hz system, auxiliary voltage 220~240 V AC


ha

PFR80 - 220 - 60 8 Steps, 60 Hz system, auxiliary voltage 220~240 V AC


en

PFR120 - 220 - 60 12 Steps, 60 Hz system, auxiliary voltage 220~240 V AC


di

PFR140 - 220 - 60 14 Steps, 60 Hz system, auxiliary voltage 220~240 V AC