Medium Voltage VFD Selection
Medium Voltage VFD Selection
Medium Voltage
Drive
Catalogue
Midea Group
The Midea Group, with the vision of “bringing great innovations to life” ,
has upheld the philosophy of creating a better life through technology
since its establishment. Based on 55 years’ of development, Midea has
evolved into an international tech-leading company which specializes in
five major businesses including Smart Home Business, Industrial Technolo-
gies, Building Technologies, Robotics &Automation, and Digital Innovation
Business.
190k A/A3/A
Number of Employees S&P/Moody's/Fitch Credit Ratings
500 200+
million Customers Countries & Regions
01 02
Business Group
Midea's Industrial Technology Business Group is one of the five business segments of Midea Group.
It aggregates core scientific and technological strengths in four major fields: intelligent transporta-
tion, industrial automation, green energy, and consumer appliances.
Its product range includes high-precision core components such as compressors, motors, chips,
automotive components, electronic expansion valves, inverters, servo and motion control systems,
gearboxes, and heat dissipation components.
Our brand
27 5600+ 51% 70
R&D & testing centers Licensed Patents Research talents Drafted & participated
in the release of standards
Its products benefit nearly 3 billion consumers worldwide, with 70% of its business focused on green and sustainable products.
03 04
Milestone
05 06
R&D-Driven Innovation
Germany 3
Switzerland 1 Hungary 1
Italy 3
China 15
USA 3 Japan 2
Korea 1
Israel 1
Singapore 1
07 08
NO.1
in the industry to conduct
the mechanical back-to-back test
Real load testing
Manufacturing Quality
10+10
Test platform and ageing platform
Advanced
technology
High-performance external
water circulation
45 days
Shortest lead time
100,000 level
Dust free plant
09 10
Products at a Glance
01
11 02
12
Air-Cooled VFD Solution
High Performance
·Single control board: simplified control system
·Efficient response speed
·High-speed optical fiber communication
Flexibility
Compact Design ·Bypass optional function
Reliability Intelligence
·Better than IEEE519 ·Integrated digital cloud platform, digital O&M
·Lower harmonic ·Fault classification and storage for accurate location
·Carrier phase-shifting algorithm ·Real-time monitoring of key device temperature
·Fault diagnosis and prediction in advance
Naming rules
② Series Number
1000: General VFD (H-bridge)
2000: Low VoltagelGBT
① HC: Hiconics VFD
Four-quadrant VFD
13 14
Air-Cooled VFD Solution
5th Generation Double Side Operation 5th Generation Double Side Operation
6kV 10kV
Power Capacity Model Weight (kg) Dimensionn (W x D x H (mm) ) Power Capacity Model Weight (kg) Dimensionn (W x D x H (mm) )
200 250 HC1000-060/00250 1919 220 275 HC1000-100/00275 2240
MA1.1
400 500 HC1000-100/00500 2383
450 560 HC1000-060/00560 2269
560 700 HC1000-060/00700 2424 560 700 HC1000-100/00700 2593
H:2200mm
H:2700mm
H:2200mm
1800 2250 HC1000-100/02250 5270 :1
65
0m
m
W:2500mm D
H:2400mm
MA3.1
2500 3150 HC1000-100/03150 7678
m
0m
W1:2250mm 60
D:1
1800
W2:2000mm
2250 HC1000-060/02250 5975 W:4250mm
H:2900mm
H:2400mm
2000 2500 HC1000-060/02500 6140
3150 4000 HC1000-100/04000 8958 W1:2250mm W2:2000mm D:1
60
0m
m
W:4250mm
H:2900mm
MA4.1
H:2400mm
H:2930mm
m
0m
ML4.1
H:2900mm
40
H:2400mm
W1:2700mm W2:2600mm D:1
W:5300mm
17 18
Air-Cooled VFD Solution
5th Generation Front Side Operation 5th Generation Front Side Operation
10kV 11kV
Power Capacity Model Weight (kg) Dimensionn (W x D x H (mm) ) Power Capacity Model Weight (kg) Dimensionn (W x D x H (mm) )
H:2700mm
690 860 HC1000-110/00860- 3839
H:2200mm
m
250 320 HC1000-100/00320 3313 20
0m
MB1.1S
280 350 HC1000-100/00350 3363 950 1190 HC1000-110/01190 4239
H:2700mm
1100 1380 HC1000-110/01380 4539
H:2200mm
315 400 HC1000-100/00400 3413 20
0m
m
H:2700mm
H:2200mm
1640 2040 HC1000-110/02040 5274
H:2700mm
H:2200mm
400 500 HC1000-100/00500 3513 20
0m
m
W1:1800mm D:1
1770 2220 5445
W2:2350mm
W:4150mm
MB2.1S HC1000-110/02220 W1:2100mm W2:2700mm 20
0m
m
D:1
W:4800mm
H:2700mm
H:2200mm
2340 2920 HC1000-110/02920 6198
m
0m
560 700 HC1000-100/00700 3713 W1:2100mm W2:2700mm
W:4800mm
D:1
20
H:2900mm
H:2400mm
MB3.1S
710 900 HC1000-100/00900 3913
3510 4390 HC1000-110/04390 8916 W1:2300mm W2:3600mm 20
0m
m
D:1
W:5900mm
H:2200mm
H:2700mm
H:2200mm
MA1.1S
1400 1800 HC1000-100/01800 5033 450 560 HC1000-060/00560 2917 20
0m
m
W1:1800mm W2:1550mm
D:1
W:3350mm
H:2700mm
H:2700mm
H:2200mm
800 1000 HC1000-060/01000 3713
m
0m
20
H:2700mm
W1:2100mm
900 1150 HC1000-060/01150 3917
W2:1950mm
D:1
HC1000-100/02800
W:4050mm
2250 2800 6291
H:2200mm
0m
m MA2.1S
W1:2100mm W2:2700mm
W:4800mm
D:1
20
1000 1250 HC1000-060/01250 4019
H:2700mm
H:2200mm
1120 1400 HC1000-060/01400 4219
2500 3150 HC1000-100/03150 7513 m
0m
W1:2100mm W2:1950mm 20
1250 1600 HC1000-060/01600 4424 W:4050mm
D:1
H:2400mm
H:2900mm
m
0m
H:2400mm
3150 4000 HC1000-100/04000 8413 W1:2300mm W2:3600mm
D:1
20
MA3.1S
W:5900mm
6.6kV 3.3kV
Power Capacity Model Weight (kg) Dimensionn (W x D x H (mm) ) Power Capacity Model Weight (kg) Dimensionn (W x D x H (mm) )
H:2700mm
MC1.1S
H:2200mm
m
250 310 HC1000-033/00310 2386
H:2700mm
570 710 HC1000-066/00710 3142 20
0m
H:2200mm
W1:1800mm W2:1550mm
W:3350mm
D:1
MD1.1S
m
0m
660 830 HC1000-066/00830 3192 290 360 HC1000-033/00360 2456 W1:1800mm W2:1200mm
W:3000mm
D
:1
20
H:2700mm
H:2200mm
840 1050 HC1000-066/01050 3508
m
0m
W1:2100mm W2:1950mm
W:4050mm
D:1
20
420 530 HC1000-033/00530 3114
H:2700mm
H:2700mm
H:2200mm
H:2200mm
1240 1550 HC1000-066/01550 4018 MD2.1S m
m 0m
20
W1:2100mm W2:1950mm
D:1
20
0m
620 780 HC1000-033/00780 3439 W1:2100mm W2:1350mm
W:3450mm
D:1
W:4050mm
1400 1750 HC1000-066/01750 4224
700 880 HC1000-033/00880 3472
1500 1870 HC1000-066/01870 4425
MC3.1S
H:2400mm
D:1
W:4550mm 930 1160 HC1000-033/01160 3730
H:2900mm
H:2400mm
2250 2800 HC1000-066/02800 5991 MD3.1S
1060 1320 HC1000-033/01320 3930 W1:2100mm W2:1550mm
W:3650mm
H:2200mm
MJ1.1S m
620
H:2700mm
MJ2.1S
780 980 HC1000-416/00980 3228
H:2200mm
W:4050mm
H:2400mm
MJ3.1S
1330 1660 HC1000-416/01660 4430 m
0m
W1:2100mm W2:2450mm 20
D:1
W:4550mm
Power unit
Water-cooled radiator uses vacuum welding technology
capable of operating at water pressures up to 12 bar.
Utilize astacked busbar design for minimal parasitic
inductance and a compact unit structure.
Buffer tank
Cold water circulation pump
Plate heat exchanger
Deionization resin
More compact in size Less environmental More cost-effective
constraints
Control room Recirculating pure water-cooled unit
unit size is 30%smaller Operable in dusty and particular lower maintenance costs Feature centralized control for All components in the pipeline loop are made of
convenience and speed,including: stainless steel.
environments without being reduced risk of failure Independent deionized water treatment bypass
Temperature control of transfomers
affected by room temperature significant energy savings Protection and control of the variable device.
frequency drive in the water-cooled Secondary cooling uses a water-to-water method,
cabinet offering high heat exchange efficiency.
Independent PLC monitoring system for remote
control capabilities.
23 24
Water-cooled VFD Solution
4th Generation Double Side Operation
6kV
Power Capacity Model Weight Dimension Power Capacity Model Weight Dimension
3600 4500 HIVERT-Y/T 06/425W 15000 LLW7.2 12500 16000 HIVERT-Y/T 10/1000W 33500 18400x1600*2400
6kV
Power Capacity Model Weight Dimension
10kV
Power Capacity Model Weight Dimension
25 26
No.3, Boxing 2nd Road,
Beijing Economic and Technological
010-59180000
400-058-6116
[email protected]
www.hiconics-global.com
27 28