Parameter List
Printed 10-2012
Book No. 584613–02 rev. 5
Published By:
Alfa Laval Tumba AB
SE-147 80 Tumba, Sweden
2 Operation Modes 15
2.1 Change-over Sequence 15
2.1.1 Change-over without calibration 15
2.1.2 Calibration of the water flow via SV10 15
2.2 Discharge 17
3
1 Parameter list
4 5 6
NOTE 1 2 3
. 0
Relevant parameters only are shown on the display.
REMOTE
i
HEATER DISCHARGE
SEPARATOR CONTROL
CIP
FEED SLUDGE CLEANING
PUMP PUMP IN PLACE
X023912A
i
HEATER DISCHARGE
SEPARATOR CONTROL
can be read.
4. I/O Test – Here it is possible to activate all
outputs and to read the status for all inputs, for
testing purposes.
5. Alarm history – List of alarms which have been
rectified. The latest alarm shows at the top of
the list.
6. System info
7. IP settings
8. Password / Login
9. Set contrast
5
1.1 Setting List 1 Parameter list
. 0
REMOTE
i
HEATER DISCHARGE
SEPARATOR CONTROL
CIP
FEED SLUDGE CLEANING
PUMP PUMP IN PLACE
X023915A
1 2 3
. 0
NOTE
REMOTE
i
HEATER DISCHARGE
SEPARATOR CONTROL
X023913A
6
1 Parameter list 1.1 Setting List
System configuration
P107 1 Flow correction factor 1.00 0,00 2,00
P111 1@ Separator size 0 See Parameters
depending on the
setting of P111,
page 12.
P112 1 Oil type HF380 See Parameters
depending on the
setting of P112,
page 14.
P114 1@ Vibration sensor installed yes/no no Can be changed
in even in
STOP. See also
"System without
vibration sensor"
in the Operating
instructions manual.
P115 1@ Frame cover switch installed yes/no no Can be changed
in even in STOP.
See also "System
without frame
cover switch" in
the Operating
instructions manual.
P116 1 Frame cover switch disabled yes/no no See also "System
(if P115 = yes) without frame
cover switch" in
the Operating
instructions manual.
P117 Not used
P118 1@ Sludge pump installed yes/no no Can be changed in
even in STOP.
7
1.1 Setting List 1 Parameter list
8
1 Parameter list 1.1 Setting List
9
1.1 Setting List 1 Parameter list
10
1 Parameter list 1.1 Setting List
11
1.1 Setting List 1 Parameter list
12
1 Parameter list 1.1 Setting List
NOTE
13
1.1 Setting List 1 Parameter list
14
2 Operation Modes
15
2.1 Change-over Sequence 2 Operation Modes
Test of calibration
The calibration is repeated at every (P242)
discharge. The measured time to fill the bowl
is then compared with the saved time used to
calculate the SV10 flow rate (the old value is
not changed).
16
2 Operation Modes 2.2 Discharge
2.2 Discharge
During discharge three different sequences are
run through:
Sequence Diagram
If a combination of low PT4 pressure (P154) and low speed (P180) is detected when the feed is
on, the system will go to STOP immediately without waiting the time in P238. Alarm ‘A57 Oil
leaking from bowl’.
17