Kransysteme

12.11.2025
From ABUS Kransysteme GmbH
Jo-Achim Visarius
Service Export Department
Tel. 02261-37-151
Fax 02261-37-90382
eMail [email protected]

Parameter for LIS-SV


Order number 36251284-2
Hoist 1 S/N 250-133733 Hoist 2 S/N
Hoist type GM3000L 2/1 Hoist type

LIS-SV1 device tag U32 LIS-SV1 device tag


LIS-SV2 device tag LIS-SV2 device tag
Load pin serial no. G69G-0586 Load pin serial no.

Hoist 1 Hoist 2
S/N 250-133733
Parameter Unit Designation
GM3000L 2/1
U32
0.0 t Load capacity total 3,500
1.0 t Load capacity hoist 1 3,500
2.0 t Load capacity hoist 2 0,000
3.0 t Load capacity hoist 3 0,000
4.0 % Overload shut-down total 110 110
4.1 % Overload shut-down hoist 1 110 110
4.2 % Overload shut-down hoist 2 110 110
4.3 % Overload shut-down hoist 3 110 110
4.40 % 2nd overload shut-down total 110 110
4.41 % 2nd overload shut-down hoist 1 110 110
4.42 % 2nd overload shut-down hoist 2 110 110
4.43 % 2nd overload shut-down hoist 3 110 110
4.5 % External part load switch 110 110
5.01 — Sensitivity to rapid load increase 255 255 255 255
5.6 — Current correction factor 0613 0613 1381 1381
5.7 — Operating on twin hoist - - 00
5.8 — Hoist synchronisation control - - 00
1.3 kHz Frequency at empty hook hoist 1 0,453
1.4 — Amplification factor hoist 1 10,864
2.3 kHz Frequency at empty hook hoist 2 0,000
2.4 — Amplification factor hoist 2 0,000
3.3 kHz Frequency at empty hook hoist 3 0,000
3.4 — Amplification factor hoist 3 0,000
5.11 i Gearbox ratio 0,00 0,00 0,00 0,00
5.12 Hz Maximum motor speed 0100 0100 0050 0050
5.14 min Run-on time for auxiliary fan 3 3

Attention: The load pin values of P1.3, P1.4, P2.3, P2.4, P3.3, and P3.4 are calculated values which are only valid for the load
pin mentioned above. Precise load calculation is only achieved by adjustment on site with known load. The correctness of the