0% found this document useful (0 votes)
2 views1 page

BKAG n3-02-01 TTD 300 KV en

Brugg offers dry type transformer sockets (TTD) for system voltages up to 550 kV, designed for easy installation on any transformer. The sockets are factory tested for reliability and made from UV and corrosion-resistant materials suitable for both indoor and outdoor use. Key features include high flexibility, operating current of 4000 A, and short circuit current capability of up to 50 kA for 3 seconds.

Uploaded by

vikivarma147
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2 views1 page

BKAG n3-02-01 TTD 300 KV en

Brugg offers dry type transformer sockets (TTD) for system voltages up to 550 kV, designed for easy installation on any transformer. The sockets are factory tested for reliability and made from UV and corrosion-resistant materials suitable for both indoor and outdoor use. Key features include high flexibility, operating current of 4000 A, and short circuit current capability of up to 50 kA for 3 seconds.

Uploaded by

vikivarma147
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Dry type plug in GIS and Transformer terminations

Transformer Sockets type TTD


Sockets up to 550 kV

Brugg dry type sockets offer high flexibility to oil insulated


transformers for system voltages up to 550 kV. Regardless of
whether the required dimensions of the cable compartment
are for dry type terminations according to EN 50299‑2 or fluid
filled terminations according to EN 50299‑1, each socket is
provided with all necessary elements for the fast and easy
installation to any transformer independently of the
manufacturer. For the long-term reliability all sockets are in
addition factory tested as per EN 50089 requirements. All
materials used are UV and corrosion resistant thus allowing the
terminations to be applicable for both indoors and outdoors
installations.

Product main features


* Designs according to EN 50299‑1/ ‑2
* Factory tests according EN 50089
* Complete set ready for installation
* Easy adaptation to all transformers
* Operating current 4000 A
* Short circuit current up to 50 kA, 3 sec

Main dimensions according to EN 50299-1 / -2


Type Q V d8 P+10 d10 S D
mm mm mm mm mm mm mm

TTD 72.5 kV 310 120 259 120 299 80 270


TTD 72.5 kV ext. 583 120 259 120 299 80 270
TTD 145 kV 470 120 298 120 350 80 320
TTD 145 kV ext. 757 120 298 110 350 80 320
TTD 145/170 kV 470 120 298 110 348 80 320
TTD 145/170 kV ext. 757 120 298 110 348 80 320
TTD 245/300 kV 620 160 451 160 500 110 475
TTD 245/300 kV ext. 960 160 559 150 500 110 582
TTD 420/550 kV 960 160 617 160 690 110 640
TTD 420/550 kV ext. 1400 160 617 160 690 110 640

Technical data
Type Insulator size Drawing Part no Description Q
mm

TTD 72.5 kV T0 S2038 80168 dry type, fixing ring cylindrical 310
TTD 72.5 kV ext T0-L S2041 80166 dry type, fixing ring cylindrical 583
TTD 145 kV T1 S2039 80167 dry type, fixing ring cylindrical 470
TTD 145 kV ext T1-L S2040 80169 dry type, fixing ring cylindrical 757
TTD 145/170 kV T2 S1940-4 89448 dry type, fixing ring cylindrical 470
TTD 145/170 kV ext. T2-L S1939-4 89449 dry type, fixing ring cylindrical 757
TTD 245/300 kV T3 S2043 89451 dry type, fixing ring cylindrical 620
TTD 245/300 kV ext. T3-L S1909-4 89396 dry type, fixing ring cylindrical 960
Subject to change without notice

TTD 420/550 kV T4 S2025 80072 dry type, fixing ring cylindrical 960
TTD 420/550 kV ext. T4-L S2026 80070 dry type, fixing ring cylindrical 1400
20251121-1

Brugg Kabel AG
Phone +41 56 201 37 77 l [email protected]

You might also like