0% found this document useful (0 votes)
248 views1 page

ADEX Optimized Control of IKN Type Coolers - Cement - Industries - ADEX

ADEX has developed an optimized control system for IKN type coolers used in cement production, which is crucial for managing the flow rate and temperature of secondary air in the clinker process. The innovative design of the IKN cooler requires careful control of both the slope size and the thickness of the clinker bed, presenting unique challenges due to dynamic behavior and measurement difficulties. The successful implementation of adaptive predictive control at Gador's cement factory has led to significant advancements in clinker cooling technology across multiple plants.

Uploaded by

Amr A. Nader
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
248 views1 page

ADEX Optimized Control of IKN Type Coolers - Cement - Industries - ADEX

ADEX has developed an optimized control system for IKN type coolers used in cement production, which is crucial for managing the flow rate and temperature of secondary air in the clinker process. The innovative design of the IKN cooler requires careful control of both the slope size and the thickness of the clinker bed, presenting unique challenges due to dynamic behavior and measurement difficulties. The successful implementation of adaptive predictive control at Gador's cement factory has led to significant advancements in clinker cooling technology across multiple plants.

Uploaded by

Amr A. Nader
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

6/21/12

ADEX Optimized Control of IKN Type Coolers | Cement | Industries | ADEX

C ontact Sitemap Espaol

Technology
Overview Energy Aerospace Petrochemical Water Cement Metallurgical Pulp & Paper Oil & Gas

Systems and Platforms

Products

Industries

About ADEX

Information Center

Home Industries Cement ADEX Optimized Control of IKN Type Coolers

ADEX Optimized Control of IKN Type Coolers


It is well known that the cooler control plays a fundamental role in the clinker process optimization due to its influence in the flow rate and the temperature of secondary air reentering the furnace. The first application of adaptive predictive control in the Gadors cement factory cooler meant an outstanding technological progress. Its success was exposed on the first Colloquium Cement and Concrete in the year 1991, and extended this solution to multiple cement plants. Later technological evolution introduced a new type of clinker cooler (IKN) (shown in the first figure), where the clinker coming from the furnace doesnt fall directly on the mobile grid of the cooler, instead it is dropped into a steady surface in which it forms a slope cooled by a fan acting directly on it, before it falls on to the mobile grid. This new clinker coolers arrangement brought, as pred ictable, a new control problem. The optimization of this process requires simultaneously a good control of the slopes size and a good control of the thickness of the clinkers bed on the mobile grid. Clinker IKN Cooler The clinker IKN cooler (shown at the left) must refrigerate the hot clinker coming from the furnace in order to allow subsequent transport and storage and recover heat energy introducing the hot air produced by the refrigeration process (called secondary air) into the furnace. Thus it is necessary to stabilize the flow rates of air in the fans and the thickness of the clinkers bed acting, both, on the speed of the fans and of the mobile grid.

Problems associated to the IKN grid Two variables must be controlled, the size of the slope and the thickness of the clinkers bed on top of the grid, with only one control action: the grids movement speed. Of course, the process presents other difficulties: great changes on the dynamic behavior of the process, lack of a direct measurement of the clinkers bed thickness, strong non-measurable perturbations, etc. The figure at the left shows the most significant process variables in the plant before the ADEX solution was applied.