COMMBOG01EN
COMMBOG01EN
SAFET Y
Combined pressure/vacuum Wide range of versions and accessories Easy, fast and economical maintenance Low pressure leak tightness Technical support for dimensioning Hygienic design
WWW.SERVINOX . COM
COMM BOG 01 EN
APPLICATION: BOG safety valves are tank safety devices (tanks not covered by PED 97/23/CE, with a working pressure < 0.5 bars) Depending on the model chosen, BOG safety valves protect low pressure tanks from overpressure and vacuum (breaking vacuum) SERVINOX possesses design tools to dimension a valve with respect to tank characteristics (diameter, height), its resistances (pressure and vacuum) and washing conditions (temperature, flow-rate) BOG safety valves are designed only to transport gases; if the valve is actuated, it must be removed and cleaned manually. TECHNICAL DATA: Materials: Parts in contact with product: 1.4404 stainless steel (316L) Gaskets: EPDM Discs: PTFE Characteristics: BOG safety valves are proposed in ND 40, 65, 100 and 150, compliant with most connection standards (DIN, SMS, OD, ISO; for ISO, ND 32, 50, 80 and 125). This equipment it totally autonomous, requiring no external control for its operation. In the standard version, pressure calibration is done with a stainless steel weight mounted on a PTFE disc, vacuum calibration is with a PTFE disc and pressure blowoff is not collected. In the standard version, pressure calibration must be between +2 and +50 mbars, and vacuum calibration is set at -2 mbars (for other calibrations, see the "Options" section); connections are welded In the standard version, the valves are designed to operate at a maximum pressure of 0.5 bars, and at a maximum temperature of 120C. Elastomers and plastics used are US FDA compliant.
OPTIONS: - Pressure blowoff collected - ATEX version 94/9/CE, zones 1 & 2, gases and dust (requires the pressure blowoff collection option) - Protection against freezing by a temperature probe, heater cable and thermostat, to ensure valve operation at outdoor temperatures lower than 0C - Dripping collector and vacuum insect trap filtration - Washing nozzle (requires the dripping collector and insect trap filter) - SMS 25 male connector on elbow for sterile air admission, enabling the use of a single tank tap for protection (pressure and/or vacuum) and to create an inert atmosphere - Inductive opening detection (PNP/NPN programmable) in vacuum - Pressure calibration with spring (60 to 490 mbars), requires the pressure blowoff collection option - Vacuum calibration by stainless steel weight, from -5 to -50 mbars - Vacuum calibration by external spring, for calibration lower than -50 mbars - Female connections by clamp or flange - Gaskets adapted to operating conditions (FKM, silicone, nitrile) - Other grades of material on demand COMMISSIONING AND MAINTENANCE: For all information concerning installation, commissioning, use and maintenance of this equipment, refer to technical notice XXX x F.
WWW.SERVINOX . COM