Internal
OTA101104 OptiX Metro 500 Hardware Description
ISSUE 1.10
www.huawei.com
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
OptiX Metro 500 is new generation optical transmission equipment, based on the current status and development trend of the metropolitan area network (MAN). The equipment supports Ethernet, SDH, and PDH, to transmit voice and data services on a single platform efficiently.
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 2
Learning Guide
Metro 500 System Description Metro 500 Maintenance Manual Metro 500 Installation Manual Metro 500 Hardware Description Manual
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 3
Upon completion this course, you will be able to: Know the network application of OptiX Metro 500. Understand the hardware structure and features of OptiX Metro 500. Understand the functions of normally used units.
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 4
Chapter 1 Network Application Chapter 2 Hardware Structure Chapter 3 Units Introduction Chapter 4 Main Features of OptiX Metro 500
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 5
Network Application
Network Application
OptiX OSN OptiX Metro OptiX Metro Backbone layer
OptiX Metro
OptiX Metro Convergence layer
OptiX Metro
OptiX Metro
OptiX Metro
OptiX Metro
Access layer
GSM
PDH
DDN
Ethernet
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 6
Network Application
Networking
The following network topologies are supported by Metro
500
Link Topology
Ring Topology
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 7
Chapter 1 Network Application Chapter 2 Hardware Structure
2.1 Equipment Types 2.2 System Structure
Chapter 3 Units Introduction Chapter 4 Main Features of OptiX Metro 500
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 8
Hardware Structure
Equipment Types
There are two equipment types of OptiX Metro 500
OptiX Metro 500 I and OptiX Metro 500 II
OptiX Metro 500 I
HUAWEI TECHNOLOGIES CO., LTD.
OptiX Metro 500 II
All rights reserved Page 9
Hardware Structure
Equipment Types
OptiX Metro 500 II has the similar functions with type I except
for the size and power supply.
OptiX Metro 500
E1 Interface T1 Interface E1 8/16/24/32 75/120 T1 16 10/100M 4 EFT N64 Service 2 V.35/V.24/X.21/RS-499/EIA-530 interfaces 2 Framed E1 interfaces 64 Kbit/ s timeslot cross-connection STM-1 Optical Interface Protection 1/2 STM-1 Optical Interface uni/bi-directional path protection and linear multiplex section protection (MSP)
OptiX Metro 500
Same with OptiX Metro 500
Ethernet Interface 10/100M 2 (ET1D
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 10
Hardware Structure
Equipment Types
OptiX Metro 500
External Clock Interface Management interface One 75 /120 external clock interface Clock signal: 2048 kbit/s or 2048 kHz One auxiliary data interface for transparent transmission of serial data One Ethernet management interface Alarm Interface SSM protocol DCC Power Supply 3-input and 1-output Boolean alarm interface Yes DCC channel transparent transmission 220V AC (90~300V) -48V DC (-36~-72V) +24V DC (18V~36V) 220V AC (90~300V) (built-in storage battery)
OptiX Metro 500
Same with OptiX Metro 500
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 11
Hardware Structure
Equipment Types
OptiX Metro 500
Flexible Installation On the wall In 19-inch cabinet In 300 mm deep ETSI cabinet In 600mm deep ETSI cabinet On the desktop Size Weight 436mmX293mmX42mm 4.6kg 350mmX300mmX130mm 15.0kg
OptiX Metro 500
On the wall
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 12
Chapter 1 Network Application Chapter 2 Hardware Structure
2.1 Equipment Types 2.2 System Structure
Chapter 3 Units Introduction Chapter 4 Main Features of OptiX Metro 500
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 13
Hardware Structure
System Structure
OptiX Metro 500 I
1. Grounding Terminal 2. Indicators 6. Boolean Value Interface 11. NM Interface 3. Optical Interface 4. Reset Switch 9. Power Switch 14. extended Slot 5. Clock Input/Output Interface 10. Indicators for the Optical Interfaces 15. Fan 7. ESD Wrist Strap Jack 8. -48V Power Unit 12. Transparent Data Interface 13. E1/T1 Electrical Interface
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 14
Hardware Structure
System Structure
OptiX Metro 500 II has the same interface area with OptiX Metro 500 I.
OptiX Metro 500 II
220V AC power board 220V AC Power Unit
Storage battery Storage Battery
interfaces Interface s
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 15
Hardware Structure
System Structure
The OptiX Metro 500 I structure
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 16
Hardware Structure
System Structure
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 17
Hardware Structure
System Structure
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 18
Chapter 1 Network Application Chapter 2 Hardware Structure Chapter 3 Units Introduction Chapter 4 Main Features of OptiX Metro 500
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 19
Units Introduction
Units
Unit
SDH unit PDH unit
Related Units
SL1D SL1S PL1D PL1S SP2D PM1D
Unit Function
Access and process the STM-1/STM-4 optical signals. Access and process E1 signals. Access and process E1/T1 signals.
PL3ES PL3ED PL3ET Access and process E3/DS3 signals. PL3TS PL3TD PL3TT
Ethernet unit DDN unit Cross-connect unit SCC unit
ET1D EFT N64 ISU
Access and process 10BASE-T and 100BASE-TX Ethernet electrical signals. Add/drop 2-port V.35/X.21/RS-449/V.24/EIA-530 interface signals and 2-port Framed E1 signals. Cross-connect SDH signals with PDH signals; provide system clock for the equipment, provide interfaces between system and the Related units and functions NM system. Process the overhead of SDH signals. All rights reserved Page 20
Orderwire unit HUAWEI TECHNOLOGIES CO., LTD.
Units Introduction
Units
Unit Type Control Unit Clock Unit Cross Connect Unit Line Unit 1 2 3 4 4 Local Tributary Unit 5 5 extended Slot 6 Slot SCC STG XC SL1D SL1S PL1D PL1S Unit Name Explanation Control unit is installed automatically. The module is on ISU unit. The module is on ISU unit. Dual optical interfaces Single optical interface 16 E1 electrical interfaces 8 E1 electrical interfaces
SP2D 16 E1 electrical interfaces / E3,DS3 service unit /PL3ES/PL3ED/PL3ET / /Low rate data processing unit PL3TS/PL3TD/PL3TT / /2 10/100M Ethernet processing unit (use MFPPP) N64 /4 10/100M Ethernet processing unit use /ET1D/EFT GFP/LAPS/HDLC)
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 21
Units Introduction
ISU Unit
ISU unit is fixed in the chassis.
ISU board
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 22
Units Introduction
ISU Unit
The Integrate System Unit (ISU) accomplishes the functions of SCC unit,
line unit, tributary unit, timing unit, order-wire unit and cross-connect unit. Provide system control function for OptiX Metro 500. Provide interfaces for NE communication and network management. Implement service configuration. Provide the extended slots with clocks. Provides 1 or 2 STM-1 optical interfaces. Three optical interface type S-1.1/ L-1.1/ L-1.2 are available, the connector type is SC/PC. Provide 8 or 16 E1 electrical interfaces with 75/120 ohm impedance.
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 23
Units Introduction
ISU Unit
Provide 16 T1 electrical interfaces with 100 ohm impedance. Provide one19.2kbit/s transparent data interface. Provide 1 external clock interface. Provide 3 Boolean inputs and 1 Boolean output. Support synchronization status message (SSM) . Support DCC transparent transmission over the external clock.
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 24
Units Introduction
ISU Unit
The cross-connect unit which be integrated on ISU can realize the
service cross-connection at the VC-4 and VC-12 levels. It can crossconnect 6 x 6 VC-4 at most.
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 25
Units Introduction
ISU Unit
The relation of the ISU with other units is shown below. ISU gets power from
the power unit. It receives and processes the services of extended units. Meanwhile, it monitors the running status of the power unit and extended unit.
+5V ISU -48V Power board
vc-4 Extended board
Mornitor Line Alarm
Crossconnect unit
Tributary
Mornitor Alarm
STM-1
E1
E1
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 26
Units Introduction
Other Units
Except for the PL1S/PL1D/SL1S/SL1D/PM1D /SCC/STG/XC
units which are fixed on ISU board, all the other service units can be inserted to the extended slot.
Extend slot
These units can be inserted to extended slot
SP2D / PL3ES / PL3ED / PL3ET / PL3TS / PL3TD / PL3TT / N64 / ET1D / EFT.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 27
Units Introduction
Other Units
Front panel of SP2D unit
Front panel of ET1D unit
Front panel of N64 unit
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 28
Units Introduction
Other Units
EFT
4 3 2 1
Front panel of EFT unit
Front panel of PL3TT unit
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 29
Units Introduction
Power Units
Front panel of -48V DC power unit
Front panel of +24V DC power unit
Front panel of 220V AC / 110V AC power unit
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 30
Units Introduction
Fan Unit
The fan unit is located on the right side of the OptiX Metro 500 I.
Fan
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 31
Units Introduction
Fan Unit
The fan is used for heat dissipation to keep the equipment temperature
normal.
Both fans lead in fresh and cool air from the right side to the left side of the
equipment.
Cool wind
Ventilation flow in the OptiX Metro 500
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 32
Questions
Which network topologies are supported by OptiX Metro 500? What is the difference between OptiX Metro 500 I and OptiX Metro
500 II?
What is the logical slot number of the extended slot?
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 33
Chapter 1 Network Application Chapter 2 Hardware Structure Chapter 3 Units Introduction Chapter 4 Main Features of OptiX Metro 500
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 34
Main Features of OptiX Metro 500
Access Capability
OptiX Metro 500 provides different service access capabilities
depending on the configuration. The maximum access capability of different services are listed as follow:
Service Type STM-1 E1 service T1 service E3/DS3 service Fast Ethernet (FE) service N64kbit/s service Framed E1
HUAWEI TECHNOLOGIES CO., LTD.
Maximum Access Capability 2 32 16 3 4 2 2
All rights reserved Page 35
Main Features of OptiX Metro 500
Management Mode
OptiX Metro 500 support two different management mode:
OptiX iManager T2000 OptiX iManager T2000 performs operation, administration and maintenance (OAM) over the OptiX Metro 500, realizing service configuration and allocation, and ensuring reliable running of the network.
Web-LCT In the terminal computer with an Explorer of Release 5.0 or above, input the IP address, you can configure services or query alarms of the OptiX Metro 500, as well as other NMS operations.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 36
Main Features of OptiX Metro 500
Network Protection
OptiX Metro 500 supports the following network protection:
Path Protection Two-fiber unidirectional path protection ring Two-fiber bidirectional path protection ring Linear MSP 1+1 linear MSP 1:N linear MSP In addition, the OptiX Metro 500 supports SNCP for the EFT only.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 37
Main Features of OptiX Metro 500
Power Supply Protection
OptiX Metro 500 Type I
-48V (+24V) DC: It provides two DC power supply ports, backing up each other. The two internal power modules back up each other. Monitor the input voltage and generate alarms for over-voltage or under-voltage. 220V AC: Two internal power modules back up each other. Provide alarms upon power module failure.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 38
Main Features of OptiX Metro 500
Power Supply Protection
OptiX Metro 500 Type II
It provides the storage battery. If the 220V AC works normally, the storage battery is charged. If the 220V AC is powered off, the storage battery starts to provide power for the equipment. It provides under-voltage protection for the storage battery.
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 39
Questions
Which management types are supported by OptiX Metro
500?
Which network protections are available with OptiX
Metro 500?
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 40
Summary
Network Application Hardware Structure Units Introduction Main Features of OptiX Metro 500
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
Page 41
Thank You
www.huawei.com