Commissioning RET Using
Antenna Rosenberger in
SBTS17A
Initial Information
• BTS Type : Airscale BTS
• BTS SW version :SBTS17A_ENB_0000_000430_000304
• Antenna Type : Rosenberger (BA-G7W8W8W8W8X65V-11) 10 Port
Antenna Port Assignment and RET Setting
R1:LWG900 Y2:TDD Ant3,4
Y1:TDD Ant1,2
Y3:LG1800 Y4:LU2100
RET PORT
AZNA
FXED FRGU
FXDB
Wiring Diagram
Initial configuration
RET Activation
Add & setup MO RSL
• Go to Parameter RMOD(which will be setup as RET controller)
• Add MO “RSL”
• Set power DC to “true”
• Set HDLC Enabled to “true”
RET Activation
• After plan activation, RET should be detected by
BTS
Check One by One RETU
which covered Port
- RETU-1 for R1
- RETU-2 for Y1
- RETU-3 for Y2
- RETU-4 for Y3
- RETU-5 for Y4
RET Activation
Add & Setup MO “LOGLINK”
• Go to Parameter HWTOP-1
• Add MO “loglink”
• Please refers to Runtime view to fill “firstEndpointDN” &
“secondEndpointDN” for this MO
RET Commissioning
• Go To Parameter Editor
• Add MO ALD-1 under APEQM
• Fill in Details ALD parameters
Commissioning
• Add MO RETU-1 until RETU-5
• Please refer to site Runtime View to check RETU’s in detail.
• If others RET were planed to be used by other’s, fill “external” in
associated Antenna list
• Fill in the additional info as request by Project
• Please follow as example below
Additional Information sample
Commissioning
Runtime View Result
Commissioning template
RETU1
Additional Information list
Commisioning
Runtime View Result
Commissioning template
RETU2
Additional Information list
Commisioning
Runtime View Result
Commissioning template
RETU3
Additional Information list
Commisioning
Runtime View Result
Commissioning template
RETU4
Additional Information list
Commisioning
Runtime View Result
Commissioning template
RETU5
Additional Information list
Site Runtime View
After Plan Activation
RET testing
Calibrating Sample test
Angles adjusting
Before
Angles adjusting
After
Rosenberger Antenna
Datasheet
TERIMAKASIH