Photovoltaic Project Analysis
Using RETScreen software
http://www.retscreen.net/ Case study : 36 kWp installed in South of
Spain, grid connected, fix structure
Fernando Nuño
European Copper Institute
[email protected]
January 09
In cooperation with Infrysol
http://www.infrysol.com/
Index
What a PV system consists on?
Fix Structure vs Tracking System
RETScreen Analysis
– Required inputs
– Computing
– Results
www.leonardo-energy.org
What a PV system consists on?
Photovoltaic
Photovoltaiccells
cells
connected
connectedinto
into
modules
modules
Modules
Modulesgrouped
groupedintointo
panels,
panels,panels
panels
grouped
groupedinto
intoarrays
arrays
Power
Powerconditioning
conditioning
unit
unit(inverter)
(inverter)
Transformer
Transformer
Grid
GridConnection
Connection
Pictures: Fernando Nuño
www.leonardo-energy.org
Fix Structure vs Tracking System
Easy to install and No moving parts, lower Average production in
operate maintenance, more South of Spain : 1500
reliable operation kWh/kWp
Needs higher maintenance Average production in
Needs more solid
and suffers higher risk of South of Spain : 2000
foundations and stiff
unscheduled outages kWh/kWp (+30%)
structure : +1€/Wp
Pictures: Fernando Nuño
www.leonardo-energy.org
Analysis with RETScreen – Required inputs
Technical characteristics
Selected
SelectedPV
PV Nominal Power under Standard conditions Investment
Investment
panels
panels
Selected
Selected Efficiency in operation Investment
Investment
Inverters
Inverters
Transformer Efficiency in operation Investment
Transformer Investment
Cabling, civil works, grid connection
Miscellaneous
Miscellaneous works, support structure / trackers Investment
Investment
Owned : how much it cost?
Land
Land Renting: annual fee? Investment
Investment
Recurrent costs: monitoring and security,
Annual
Annual
Operation
Operation tracker maintenance, land renting,
insurances expenditure
expenditure
www.leonardo-energy.org
Analysis with RETScreen – Required inputs
Selected
SelectedPV
PV
panels
panels
1.94 m2
280 Wp
Efficiency = 280 W / [1,94 m2 * 1000 W/m2] = 14.4%
Picture: Suntech
www.leonardo-energy.org
Analysis with RETScreen – Required inputs
Selected
Selected
inverters
inverters
3.5 kW
95% eff
Picture: Fronius
www.leonardo-energy.org
Analysis with RETScreen – Required inputs
Site
Site Location
characteristics
characteristics
Here
Here
www.leonardo-energy.org
Analysis with RETScreen – Required inputs
Site
Site Building orientation related to
characteristics North/South and roof slope
characteristics
β α ε
South
Picture :
www.leonardo-energy.org
Analysis with RETScreen – Computing
Project
Project Cle
Clean
anEne
Energy
rgyProje
ProjectctAnalys
AnalysisisSSoftware
oftware
Information
Information
Project
Projectinformation
information
S e e proje ct databas e
S e e proje ct databas e
Project name Pedro Muñoz - Fix
Project name Pedro Muñoz - Fix
Project location Pedro Muñoz - Castilla la Mancha - Spain
Project location Pedro Muñoz - Castilla la Mancha - Spain
Prepared for Leonardo Energy Webinars
Grid Prepared for
Prepared by
Leonardo Energy Webinars
Fernando Nuño
connected or Prepared by Fernando Nuño
off-grid
Project type Power
applications Project type Power
Technology Photovoltaic
Technology Photovoltaic
Grid type Central-grid
Grid type Central-grid
Analysis type Method 1
Analysis type Method 1
Two types of
analysis : Heating value reference
Heating value reference
Lower heating value (LHV)
Lower heating value (LHV)
first Show settings
Show settings
approach or Language - Langue English - Anglais
developed in Language - Langue English - Anglais
User manual English - Anglais
User manual English - Anglais
depth
Currency Euro
Currency Euro
Symbol
Symbol
Units Metric units
Units Metric units
www.leonardo-energy.org
Climate data location
Climate data location
Analysis with RETScreen – Computing
Site
Sitereference
reference
conditions
conditions
S e le ct clim ate data location
Site
Sitereference
referenceconditions
conditions S e le ct clim ate data location
Climate data location Tomelloso
Climate data location Tomelloso
Show data
Show data
Large choice
of locations
around the
world
Provides
irradiation,
temperature
and wind
data per
month
www.leonardo-energy.org
Analysis with RETScreen – Computing
Two types of
Type
Typeof
ofPV
PV analysis : 1) first
system
system approach or 2)
developed in
depth
Analysis Method
Method11
Analysistype
type
Method
Method22
Photovoltaic
Photovoltaic
Resource
Resourceassessment
assessment
Solar
Solar trackingmode
tracking mode Fixed
Fixed
Slope
Slope °° 35,0
35,0
Azimuth ° 32,0
Azimuth ° 32,0
Fixed, 1 axis
track, 2 axis
track
www.leonardo-energy.org
Analysis with RETScreen – Computing
Computing
Computing slope
Analysis type slope Method 1
and
andazimut
azimut Method 2
Photovoltaic
Resource assessment
Solar tracking mode Fixed
Slope ° 35,0
Azimuth ° 32,0
Slope = arctan [tan2(α) + tan2(β)]0,5
Azimut = ε + arctan [tan(α) / tan(β)]
β α ε
South
Picture :
www.leonardo-energy.org
Analysis with RETScreen – Results
Estimated
Exported
Exported Electricity Export
Electricity
Electricity to grid
Daily
Dailysolar
solarradiation
radiation- - Daily
Dailysolar
solar Electricity
Electricityexport
export Electricity
Electricity
Month
Month horizontal
horizontal radiation - tilted
radiation - tilted rate
rate exported
exportedtotogrid
grid
kWh/m²/d
kWh/m²/d kWh/m²/d
kWh/m²/d €/MWh
€/MWh MWh
MWh
January
January 2,21
2,21 3,34
3,34 455,1
455,1 3,549
3,549
February
February 3,15
3,15 4,18
4,18 455,1
455,1 3,958
3,958
March
March 4,44
4,44 5,18
5,18 455,1
455,1 5,309
5,309
April
April 5,31
5,31 5,48
5,48 455,1
455,1 5,388
5,388
May
May 6,14
6,14 5,82
5,82 455,1
455,1 5,789
5,789
June
June 7,15
7,15 6,51
6,51 455,1
455,1 6,087
6,087
July
July 7,29
7,29 6,76
6,76 455,1
455,1 6,409
6,409
August
August 6,33
6,33 6,33
6,33 455,1
455,1 6,030
6,030
September
September 4,91
4,91 5,44
5,44 455,1
455,1 5,137
5,137
October
October 3,28
3,28 4,03
4,03 455,1
455,1 4,075
4,075
November
November 2,31
2,31 3,32
3,32 455,1
455,1 3,345
3,345
December
December 1,85
1,85 2,85
2,85 455,1
455,1 3,030
3,030
Annual
Annual 4,54
4,54 4,94
4,94 455,10
455,10 58,106
58,106
Feed-in tariff
applicable in
Spain up to
Sept 2008 www.leonardo-energy.org
Analysis with RETScreen – Results
Actual
Actualvs
vs
Estimated
EstimatedExport
Export
Actual - Expected Electricity Export
20%
Estimated Actual export to Deviation %
15%
export to grid grid
MWh MWh 10%
3,549 3,216
3,958 3,747 5%
5,309 5,764
5,388 6,042 0%
January
July
August
February
March
May
June
October
November
April
September
December
5,789 4,014
6,087 6,084 -5%
6,409 5,749
-10%
6,030 6,311
5,137 5,060
-15%
4,075 4,315
3,345 3,830 -20%
3,030 2,684
58,106 56,816 -25%
-30%
May was
-2% -35% particularl
y cloudy
and rainy
www.leonardo-energy.org
Analysis with RETScreen – Results
Number
Numberofof
panels
panels
Introduce the
power to install and
the panel efficiency
Photovoltaic
Type poly-Si
Power capacity kW 36,00
Manufacturer Suntech
Model poly-Si - STP280-24/Vb 140 unit(s)
Efficiency % 14,4%
Nominal operating cell temperature °C 45
Temperature coefficient % / °C 0,40%
Solar collector area m² 250
Obtain the number
of panels and the
solar collector area
www.leonardo-energy.org
Cost breakdown
4,5 €/W
Prices in Euros Units Price per unit Total price
PV Panels 140x280 W 140 1157 162000
Inverters 10x3500 W 10 2700 27000
Fix Structure 1 12000 12000
Low Voltage Material 1 5200 5200
Civil Works 1 1500 1500
Manforce 1 3000 3000
Project / Design 1 6000 6000
Safety Program 1 700 700
Insurance works + 1st year 1 1000 1000
Grid Connexion 1 1000 1000
Environmental
Fence
Security equipment (anti-theft)
Transformer 6,1 €/W
TOTAL 219400
www.leonardo-energy.org
Cost breakdown
COST BREAKDOWN 2007 - SPAIN
36 kW fixed - roof installed
PV Panels 140x280 W
Inverters 6x5500 W
Fix Structure
Low Voltage Material
Civil Works
Manforce
Project / Design
Safety Program
Insurance works + 1st year
Grid Connexion
www.leonardo-energy.org
Analysis with RETScreen – Results
al parameters
Financial parameters Financial parameters
rate Financial
Financial
Inflation rate Inflation rate
% % 4,0% %
4,0%
Input
ife Projectanalysis
life
analysis
Project life
yr yr 25 yr 25
s80%
io Debt ratio Debt ratio% % 80% %
erest rate Debt interest rate Debt interest
% rate % 6,00% 6,00%
%
m Debt term Debt termyr yr 10 yr 10
osts Initial costs Initial costs
ystem Power system Power system
€ € 0 € 0
Other 0,0% Other € € 219.400 219.400
€
itial costs Total initial costs Total initial
€ costs € 219.400 219.400
€
Outupts 800.000
700.000
600.000
Cumulative cash flows (€)
Financial
Financialviability
viability Output:
500.000
Pre-tax 20,0%
Pre-tax IRR- -equity
IRR equity 27,2%
27,2% %%
Cumulative 27,2%
27,2%
Pre-tax IRR - assets 7,4%
9,9% 400.000 Cash%%
Flow 9,9%
Pre-tax IRR - assets 9,9% 9,9%
Simple
Simplepayback
payback 9,6
7,9
7,9 300.000 yryr 7,9
7,9
Equity payback
Equity payback 9,8
5,6
5,6 200.000
yryr 5,6
5,6
100.000
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
-100.000
www.leonardo-energy.orgYear
Analysis with RETScreen – Results
Reference
CO2
CO2emission
emission power
generation
analysis
analysis technology
Emission Analysis
GHG emission
factor T&D GHG emission
Base case electricity system (Baseline) (excl. T&D) losses factor
Country - region Fuel type tCO2/MWh % tCO2/MWh
Spain Natural gas 0,325 10,0% 0,361
Electricity exported to grid MWh 58 T&D losses 5,0%
GHG emission
Base case tCO2 21,0
Proposed case tCO2 1,0
Gross annual GHG emission reduction tCO2 20,0
GHG credits transaction fee %
Net annual GHG emission reduction tCO2 20,0 is equivalent to 8.132
GHG reduction income
GHG reduction credit rate €/tCO2 15,00
GHG reduction credit duration yr 20 Obtain Net
GHG reduction credit escalation rate % 5,0% annual
emission
reduction
www.leonardo-energy.org
Analysis with RETScreen – Two axis track
Two
Twoaxis
axistrack
track
33.6 kW
www.leonardo-energy.org
Thank you!
SOFTWARE CASE STUDIES by:
http://www.retscreen.net/ http://www.infrysol.com/
www.leonardo-energy.org
Anex – Slope and Azimut calculations
Find γ such that
δγ/δε = 0
(maximum
slope)
β
ε
α
η=90º-ε
β α ε
South
Picture :
www.leonardo-energy.org
Anex – Slope and Azimut calculations
www.leonardo-energy.org
Anex – Slope and Azimut calculations
www.leonardo-energy.org
Anex – Slope and Azimut calculations
Find γ such that
δγ/δε = 0
(maximum
slope)
www.leonardo-energy.org
Anex – Slope and Azimut calculations
www.leonardo-energy.org
Annex – Available surface on roof
Where α is the
lowest sun
height (21
december in
North
hemisphere)
Where β is the
slope
www.leonardo-energy.org