What Is TPF?: Loss of Complete AC Power To Our Auxiliaries Is Known As TOTAL Power Failure

A Total Power Failure (TPF), also known as a blackout, occurs when there is a complete loss of auxiliary AC power. A TPF can be caused by a grid failure resulting in no power across the entire grid, all grid feeders tripping due to electrical faults, or islanding from the combined power plant end which then leads to a TPF. When a TPF occurs, it takes more time to bring a unit back up to full load and there is an increased chance of equipment breakdowns like diaphragm failures in the low pressure turbine, issues with DC drives, and barring gear failures. To protect critical equipment during a TPF, the turbine bearings, low pressure turbine diaphrag

Uploaded by

Sanjay Gupta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
240 views9 pages

What Is TPF?: Loss of Complete AC Power To Our Auxiliaries Is Known As TOTAL Power Failure

A Total Power Failure (TPF), also known as a blackout, occurs when there is a complete loss of auxiliary AC power. A TPF can be caused by a grid failure resulting in no power across the entire grid, all grid feeders tripping due to electrical faults, or islanding from the combined power plant end which then leads to a TPF. When a TPF occurs, it takes more time to bring a unit back up to full load and there is an increased chance of equipment breakdowns like diaphragm failures in the low pressure turbine, issues with DC drives, and barring gear failures. To protect critical equipment during a TPF, the turbine bearings, low pressure turbine diaphrag

Uploaded by

Sanjay Gupta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 9

WHAT IS TPF?

Loss of complete AC power to our


auxiliaries is known as TOTAL
POWER FAILURE.
TPF/ Blackout.

CAUSES OF TPF:

Grid failure (No power in the entire grid) leading


to TPF.
Tripping all grid feeders (electrical faults)
leading to TPF.
Islanding from CPP end ,subsequently leading
to TPF
POWER NETWORK:
OUR RESPONSIBILITIES
The actions which we are taking are to :-

 Protect our equipment.

 To prevent unwanted outages.


AFTER EFFECTS OF TPF

It takes more time to bring a unit, back to


full load after TPF.

Chances of Diaphragm failure of LPT


(more down time).

Chances of major equipment breakdown,


due to malfunction of DC drives.

Barring gear failure


(TG shaft getting stand still)
The things which need to be protected are:-

TG set bearings

LP turbine diaphragm

Condenser tubes

Flame scanners

Air pre heaters


General activities
Every A shift:-
 Start EOP
 Check air motor of APH.
Weekly:-
 Seal oil pump
 And check weather hand gloves,
F-handle, Torch lights are available.
 Every three months conduct mock drills.