This document is a checklist for inspecting a firewall assembly. It lists 22 items to check, including verifying dimensions and orientations of parts, inspecting fasteners, checking for holes, scratches, and sealant issues. Locations to check are identified as areas 1A through 5B for the inboard and outboard sides. Electrical bonding surfaces and areas requiring primer are also called out.

Uploaded by

revanth kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
62 views16 pages

FIrewall RH Final

This document is a checklist for inspecting a firewall assembly. It lists 22 items to check, including verifying dimensions and orientations of parts, inspecting fasteners, checking for holes, scratches, and sealant issues. Locations to check are identified as areas 1A through 5B for the inboard and outboard sides. Electrical bonding surfaces and areas requiring primer are also called out.

Uploaded by

revanth kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 16

SHIPSET NO:……….……………..

WORK ORDER NO:………………………..

DATE:………..………………

PIP ANNEXURE- FIREWALL RH-FINAL

1
Last Updated Date- 21-May-2020
Firewall

INBOARD OUT BOARD

2
Firewall Inboard B1-
B9

LOCATIONS
S.NO CHECKLIST
1A 2A 3A 4A 5A
B1 Check for all open holes as per Engineering          
B2 Verify the Edge distance in Firewall assembly As per B/P and HS217.          
Inspect all the installed fasteners as per B/P Requirement & As per HP3-0(SOLID RIVET,
INSTALLATION),
B3 HP3-1(COUNTERSINKING), HP3-2(HI-LOK, INSTALLATION), HP3-5(BOLT,BLIND          
INSTALLATION ) Check for Rivet head gaps, Rivet gap to shank, Rivet damages,
check for CSK rivet, Blind & Hilok fasteners protrusion & intrusion
Check for the orientation & floating of all Nut plates(one lug floating ,one lug fixed, two lug
B4          
floating, two lug fixed) & Brackets as per Engineering
Check for interior & exterior surfaces for any nicks and scratches as per HS217
B5          
check for part to part gap as per HS217
Check for Sealant Voids , delamination, Bubbles, Pin Holes, smoothness, uneven sealant and
B6          
incomplete sealant.
B7 Check Bearing(2 Qty) free movement condition in Firewall assembly.          
B8 Verify the electrical bonding surface protectively covered as per spec          
B9 Ensure Bare metal touch up as per spec EPB4-230 and the applicable part spec          

3
Firewall Outboard B1-
B9

LOCATIONS
S.NO CHECKLIST
1B 2B 3B 4B 5B
B1 Check for all open holes as per Engineering          
B2 Verify the Edge distance in Firewall assembly As per B/P and HS217.          
Inspect all the installed fasteners as per B/P Requirement & As per HP3-0(SOLID RIVET,
INSTALLATION),
B3 HP3-1(COUNTERSINKING), HP3-2(HI-LOK, INSTALLATION), HP3-5(BOLT,BLIND          
INSTALLATION ) Check for Rivet head gaps, Rivet gap to shank, Rivet damages,
check for CSK rivet, Blind & Hilok fasteners protrusion & intrusion
Check for the orientation & floating of all Nut plates(one lug floating ,one lug fixed, two lug
B4          
floating, two lug fixed) & Brackets as per Engineering
Check for interior & exterior surfaces for any nicks and scratches as per HS217
B5          
check for part to part gap as per HS217
Check for Sealant Voids , delamination, Bubbles, Pin Holes, smoothness, uneven sealant and
B6          
incomplete sealant.
B7 Check Bearing(2 Qty) free movement condition in Firewall assembly.          
B8 Verify the electrical bonding surface protectively covered as per spec          
B9 Ensure Bare metal touch up as per spec EPB4-230 and the applicable part spec          

4
Firewall B10

S.NO CHECK LIST

Orientation of QTY (1) MS21061L3 nutplate common to the 7-311140132-178 angle to be checked
B10 as per B/P requirements

5
Firewall B11

S.NO CHECK LIST

Check for Availability of 4 Red Dots (Proof load test Evidence) Adjacent to Bearings on
B11 Firewall Engine Mount 7-311140048-8.

6
Firewall B12 &
B13

0.220-0.226

Faying should not be present

S.NO CHECK LIST


Ensure (0.220-0.226) Hole Size for MS21075L3 Nutplate center holes on 7-511140200-23
B12 Support assembly
Ensure that no Fay seal is present between Nutplate and 7-511140200-23 Support
B13 assembly

7
Firewall B14

S.NO CHECK LIST

B14 Check for Surface irregularities in 7-311140132-64 & 7-311140132-45 & 46 Angles

8
Firewall B15

S.NO CHECK LIST

B15 Ensure the Availability of 7-311140132-179 & 7-311140132-93 Parts are Clecoed on the Final Assembly

9
Firewall B16

S.NO CHECK LIST

B16 Check for Tapered Shim b/w 7-311140132-101 Doubler and 7-311141133-4 Web

10
Firewall B17

Shim is located between 7-


3111400048-8 , 7-311140047-4 and 7-
311141133-4 Web

S.NO CHECK LIST

B17 Check for Proper Application of Shim b/w 7-311140048-8 and 7-311140047-4 and 7-311141133-4 Web

11
Firewall B18

Min ED = 0.22”

S.NO CHECK LIST

B18 Ensure ED of the Rivet C/T 7-311141144-3 Doubler and 7-311140132-52 & 7-311141133-4 Web

12
Firewall B20 &
B22

S.NO CHECK LIST

B 20 Ensure all Electrical Bonding areas are taped using appropriate tape

Ensure no Primer in indicated holes as per PL note


B 22

13
Firewall B21

S.NO CHECK LIST

Ensure Grommet Lengths on 7-311140132-64P are as per B/P


B 21

14
Firewall B23

S.NO CHECK LIST

Check whether 5th and 11th Holes are in Open conditon till Final assembly
B 23

15
Firewall B24

S.NO CHECK LIST

B 24 Ensure part marking on the Final Assembly