Design Base Shear (NSCP 1992)

This document discusses the seismic analysis of buildings according to the National Structural Code of the Philippines. It outlines the process for determining the design base shear, including defining the seismic zone factor, importance factor, numerical coefficient, fundamental period of vibration, total seismic deadload, and structural system reduction factor. The seismic zones in the Philippines are divided into Zone 2 and Zone 4. Parameters like site coefficient, structure height and type are used to calculate the fundamental period of vibration.

Uploaded by

JMSoriano
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
575 views23 pages

Design Base Shear (NSCP 1992)

This document discusses the seismic analysis of buildings according to the National Structural Code of the Philippines. It outlines the process for determining the design base shear, including defining the seismic zone factor, importance factor, numerical coefficient, fundamental period of vibration, total seismic deadload, and structural system reduction factor. The seismic zones in the Philippines are divided into Zone 2 and Zone 4. Parameters like site coefficient, structure height and type are used to calculate the fundamental period of vibration.

Uploaded by

JMSoriano
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 23

SEISMIC ANALYSIS

SEISMIC ANALYSIS

 Seismic Analysis of Three Storey Building

- Design Base Shear (NSCP 1992)

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 2015


SEISMIC ANALYSIS

SEISMIC ANALYSIS
THREE STOREY BUILDING

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992


SEISMIC ANALYSIS

DESIGN BASE SHEAR

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992


SEISMIC DESIGN & ANALYSIS

 2.2.5.2 Design Base Shear


The total design base shear in a given direction
shall be determined from the following formula:

V = Z I C WT / Rw

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992


SEISMIC ANALYSIS

TABLE 2.2A
SEISMIC ZONE FACTOR, Z

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992


SEISMIC ANALYSIS

 Seismic Zone
The Philippine archipelago is divided into two
seismic zones only. Zone 2 covers the provinces
of Palawan (except Busuanga), Sulu and Tawi-
tawi while the rest of the country in under Zone 4
as shown in Figure 208-1. Each structure shall be
assigned a seismic zone factor Z, in accordance
with Table 208-3

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992


FIGURE 2.2B
SEISMIC ZONE MAP TABLE 2.2A
OF THE PHILIPPINES SEISMIC ZONE FACTOR Z

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992


SEISMIC ANALYSIS

IMPORTANCE FACTOR

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992


TABLE 2.2C OCCUPANCY CATEGORIES

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992


SEISMIC ANALYSIS
TABLE 2.2D OCCUPANCY REQUIREMENTS

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992


SEISMIC ANALYSIS

NUMERICAL
COEFFICIENT, C

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992


SEISMIC DESIGN & ANALYSIS

Numerical coefficient be determined from the


following formula:

C = 1.25 S / T 2/3

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992


SEISMIC ANALYSIS

S = Site Coefficient for soil characteristics

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992


SEISMIC ANALYSIS

T = Fundamental period of vibration in seconds


Fundamental period of vibration in seconds, of the
structure for the direction under consideration
determined in accordance with Sec. 2.2.5.2.2
Sec. 2.2.5.2.2 Structure Period. The Value of T shall
be determined from the following methods.
Method A : For all buildings the value of T may be
approximated from the following formula
T= Ct (hn)3/4
where
Ct = 0.085 for steel moment-resisting frames
Ct = 0.075 for reinforced concrete moment-
resisting frames and eccentrically braced
frames
Ct = 0.05 for all other buildings
hn = Height, in m, above the base level n

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992


SEISMIC ANALYSIS

T = Fundamental period of vibration in seconds


Method B : The fundamental period T may be calculated
using the structural properties and deformational
chareacteristics the resisting elements in properly
subtantiated analysis.

This requirement may be satisfied by using the following


formula:

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992


SEISMIC ANALYSIS

TOTAL SEISMIC DEADLOAD, W

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992


SEISMIC ANALYSIS

The total seismic dead load defined in Section


2.2.5.1.3
(1) In storage and warehouse occupancies, a
minimum of 25 percent of the floor live load shall
be applicable.

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 2015


SEISMIC ANALYSIS

The total seismic dead load defined in Section


2.2.5.1.3
(2) Where an allowance for partition load is
included in the floor design, the applicable portion
of the load shall be not less than 0.5 Kpa.
(3) Total weight of permanent equipment shall
included.

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 2015


SEISMIC ANALYSIS

STRUCTURAL SYSTEM, RW

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 2015


SEISMIC ANALYSIS

TABLE 2.2G STRUCTURAL SYSTEMS

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 2015