Seismic Analysis of Three Storey Building
- Design Base Shear (NSCP 1992)
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 2015
SEISMIC ANALYSIS
SEISMIC ANALYSIS
THREE STOREY BUILDING
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992
SEISMIC ANALYSIS
DESIGN BASE SHEAR
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992
SEISMIC DESIGN & ANALYSIS
2.2.5.2 Design Base Shear
The total design base shear in a given direction
shall be determined from the following formula:
V = Z I C WT / Rw
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992
SEISMIC ANALYSIS
TABLE 2.2A
SEISMIC ZONE FACTOR, Z
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992
SEISMIC ANALYSIS
Seismic Zone
The Philippine archipelago is divided into two
seismic zones only. Zone 2 covers the provinces
of Palawan (except Busuanga), Sulu and Tawi-
tawi while the rest of the country in under Zone 4
as shown in Figure 208-1. Each structure shall be
assigned a seismic zone factor Z, in accordance
with Table 208-3
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992
FIGURE 2.2B
SEISMIC ZONE MAP TABLE 2.2A
OF THE PHILIPPINES SEISMIC ZONE FACTOR Z
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992
SEISMIC ANALYSIS
IMPORTANCE FACTOR
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992
TABLE 2.2C OCCUPANCY CATEGORIES
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992
SEISMIC ANALYSIS
TABLE 2.2D OCCUPANCY REQUIREMENTS
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992
SEISMIC ANALYSIS
NUMERICAL
COEFFICIENT, C
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992
SEISMIC DESIGN & ANALYSIS
Numerical coefficient be determined from the
following formula:
C = 1.25 S / T 2/3
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992
SEISMIC ANALYSIS
S = Site Coefficient for soil characteristics
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992
SEISMIC ANALYSIS
T = Fundamental period of vibration in seconds
Fundamental period of vibration in seconds, of the
structure for the direction under consideration
determined in accordance with Sec. 2.2.5.2.2
Sec. 2.2.5.2.2 Structure Period. The Value of T shall
be determined from the following methods.
Method A : For all buildings the value of T may be
approximated from the following formula
T= Ct (hn)3/4
where
Ct = 0.085 for steel moment-resisting frames
Ct = 0.075 for reinforced concrete moment-
resisting frames and eccentrically braced
frames
Ct = 0.05 for all other buildings
hn = Height, in m, above the base level n
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992
SEISMIC ANALYSIS
T = Fundamental period of vibration in seconds
Method B : The fundamental period T may be calculated
using the structural properties and deformational
chareacteristics the resisting elements in properly
subtantiated analysis.
This requirement may be satisfied by using the following
formula:
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992
SEISMIC ANALYSIS
TOTAL SEISMIC DEADLOAD, W
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 1992
SEISMIC ANALYSIS
The total seismic dead load defined in Section
2.2.5.1.3
(1) In storage and warehouse occupancies, a
minimum of 25 percent of the floor live load shall
be applicable.
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 2015
SEISMIC ANALYSIS
The total seismic dead load defined in Section
2.2.5.1.3
(2) Where an allowance for partition load is
included in the floor design, the applicable portion
of the load shall be not less than 0.5 Kpa.
(3) Total weight of permanent equipment shall
included.
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 2015
SEISMIC ANALYSIS
STRUCTURAL SYSTEM, RW
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 2015
SEISMIC ANALYSIS
TABLE 2.2G STRUCTURAL SYSTEMS
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 2015