Chemical Industry Flow Solutions
Chemical Industry Flow Solutions
Applications
Flow Challenge:
• Manganese sulphate and sulphuric acid with
Level
occasional bursts of slurry.
Environment:
Analysis
• Pipe size: 148mm ID
• Pipe material: Fibreglass
Pressure • Wall thickness: 8.4mm
• Temperature: 85C - 95C
Temperature • Flow rate: 0 - 250m³/hr
Gamma Solution:
• Prosonic flow DMU 93 with
Flow Computer, • DDU 10 high temperature sensors
Recorders,
Components
Product group: Flow Benefit:
Systems/Solutions • No contact to medium
Industry: Chemical industry
• Installation without of process
Installed at: Delta EMD, Newcastle interruption
NSW, Australia
Flow Challenge:
• Tantalum electrodes
Level • ATEX II 2G - EEx ia IIC T6
Analysis Solution:
• Chemical compatibility
Pressure ( PTFE and Tantalum wetted
parts)
Temperature • Installation philosophy
(looped power)
Gamma • Intrinsically Safe installation and
approved
Flow Computer,
Recorders,
Components Benefit:
Product group: Flow
Systems/Solutions • 25% reduced wiring/installation
Industry: Chemical industry cost compared to traditional 4
wire flowmeters
Installed at:
Flow Challenge:
• Measurement of aluminium
Level phosphate in the production of
Phosphalugel
Analysis
Environment:
Pressure • High solid content in the fluid
Temperature Solution:
• Promag 35S - because of the strong
Gamma construction it is able to measure
conductive liquids with solid content
Flow Computer,
Recorders,
Components Product group: Flow Benefit:
Systems/Solutions • Stable and precise flow measurement
Industry: Chemical industry
for high solid content
Installed at: France
Flow Challenge:
• Filling of ships, where there is no
Level space for the meter in the
installation
Analysis
Environment:
Pressure • Isolation of meter, because TDI
does harden in room temperature
Temperature
Solution:
Gamma • 80F1F-ANDS9ACAC4AA
including heating jacket
Flow Computer,
Recorders, Product group: Flow
Components
Industry: Chemical Industry Benefit:
Systems/Solutions • Compact size of meter allows
Installed at: Japan installation after a 90° bend in front of a
shut valve. No inlet or outlet restriction
and quick and easy installation.
Flow Recently Sakura Endress has sold its first Promass F DN150 to Mitsui
Takeda Chemical, a joint venture of Mitsui Chemicals Inc. and Takeda
Level
Chemical Industries Ltd. Together with Mr. Horiguchi (Tokyo Sales)
Analysis
and Mr. Suzuki (Chiba Office Sales). The Promass F DN150 is used in
a filling station for tank ships located on a quay. Currently (May 2003)
Pressure the construction of the filling station receives its finishing touches. In
this plant Mitsui Takeda Chemical manufactures TDI (Toluene
Temperature
Diisocyanate). TDI is an isocyanate used in the production of
Gamma polyurethanes for flexible foam applications ranging from furniture,
Flow Computer,
bedding, and carpet underlay, to transportation and packaging. TDI is
Recorders, also used in the manufacture of coatings, sealants, adhesives, and
Components
elastomers.
Systems/Solutions
Systems/Solutions
Flow Challenge:
• Measurement of coal gas
Level
Environment:
• Petrochemical industry; Ex-Application
Analysis
• DN 80
• Flow rate 200 - 1000 m³/h
Pressure • Pressure: 10 bar
Temperature
Solution:
• Promass 83F for gas measurement
Gamma
Flow Computer,
Recorders, Benefit:
Components • Stable measurement of flow rate
Product group: Flow • No maintenance required.
Systems/Solutions
• No straight inlet or outlet section needed,
Industry: Chemical industry save the space and money.
Installed at: China
Flow Challenge:
• Exchange of PD meters
Level
Environment:
Analysis • Fluid often plugged the PD meters.
Pressure Solution:
• Promass 83F, vertical installation,
Temperature allows self draining and easy cleaning.
Gamma
Flow Computer,
Recorders, Benefit:
Components • Easy installation
Systems/Solutions
• Self draining, no blocking of meter
• Advanced diagnostics allows to
Product group: Flow
recognize very early blocking or
Industry: Chemical Industry sedimentation.
Temperature
Requested flow: 100 – 500 GPM
Pressure: 110 – 120 PSIG
Gamma
Temperature: 200°F
Flow Computer, Density: 5.5 lbs/USGal
Recorders, Viscosity: 3.500 cP
Components
Systems/Solutions
Flow
Level
Analysis
Pressure
Temperature
Systems/Solutions
Endress+Hauser
Installation in the existing
pipeline without
additional work.
Flow Challenges:
• To get a level measurement of brine, is
very important that this application be
Level
Transmitter outside of the cell.
Transmitter • Convince the customer about the
Analysis accuracy and reliability of the Level
Flex.
Pressure
Environment:
• Close place, temperature between
Temperature
30….50ºC
Gamma Solution:
Flow Computer,
• Radar: externally assembled
Recorders,
Components Benefit:
Systems/Solutions Order code: FMP40-APP2CRJB21CA • The big advantage is the easy
Product group: Level
commissioning and start-up, on-
line level and easy change of
Industry: Chemical Industry instrument when required.
Installed at: Carbocloro Cubatão SP/ Brazil
Pressure
Temperature
Gamma
Systems/Solutions
Flow
Level
Analysis
Pressure
Temperature
Gamma
Flow Computer,
Recorders,
Components
Systems/Solutions
Temperature
• Mounting directly into the vessel is
considered now
Gamma
==> higher safety of the plant by
Flow Computer,
Recorders, reduced volume without the bypass, the
Components tubes + valves
Systems/Solutions
Level
Distillation of Raw Benzene
Analysis
Secure Level Measurement
Pressure
• Bypass and stilling Well applications
Temperature within the Petrochemical / chemical /
Energy Industries
Gamma • no risk of blocking due to no moving
parts
Flow Computer,
Recorders, • independent of foam, boiling surface and
Components changing densities
Systems/Solutions
• independent of the outlets .
Flow
Level
Pressure
• Replacement of displacer
• Less maintenance
Temperature • No recalibration of the zero due to
build-up
Gamma • no risk of blocking due to no moving
Flow Computer, parts
Recorders,
• independent of foam and changing
Components
densities
Systems/Solutions
• independent of the tank connections
Flow
Level
Analysis
Pressure
Temperature
Gamma
Flow Computer,
Recorders,
Components
Systems/Solutions
Gamma
Flow Computer,
Recorders,
Components
Systems/Solutions
Systems/Solutions
Flow
Level
Analysis
Pressure
Temperature
Gamma
Flow Computer,
Recorders, • Product: LPG
Components
• 3 Spheres, height: 12 m
Systems/Solutions Stilling well: 6“ (DN150)
with ball valve
• Pressure: 16 bar
• Device: FMR232 with planar antenna
Flow Challenge:
• Replacement of mechanical side
Level glass
• Replacement of FMU40
Analysis • Accuracy 3 mm needed
Pressure Environment:
• Ambient temperature
Temperature
Solution:
Gamma • FMR245
Flow Computer,
Recorders,
Product group: Level Benefit:
Components • Customer bought without
Systems/Solutions Industry: Chemical industry Endress+Hauser recommendation
FMU40, which didn´t reach the
Installed at: Canada accuracy caused by the ambient
environment.
Flow
Level
Analysis
Pressure
Temperature
Gamma
Flow Computer,
Recorders,
Components
Systems/Solutions
Flow Challenge:
• Cost-effective replacement for the old FMM
Level
460
• Strong electrostatic charging of product
• Ceiling with relatively low loading capacity
Analysis
Environment:
Pressure • Measured Media: PE and PP Granulate
• Measuring range 18 m
Temperature • Aluminium silo Ø approx. 3 m
Gamma Solution:
• Level flex M, FMP 40 with 4 mm rope
Flow Computer, • This rope was selected to reduce ceiling
Recorders,
Components load
Product group: Level
Systems/Solutions
Benefit:
Industry: Chemical industry • Integrated protection against electrostatic
charging
• The 4 mm rope provides ample stability (12
kN)
Levelflex M in PVC-powder
Flow Challenge:
• Silo height: 22,8m
Level
• Diameter: ca. 2m
Analysis
Environment:
• Measured Media: PVC-powder
• DC: 1,6
Pressure • Production of plastic profiles
Temperature Solution:
• Levelflex M
Gamma
Flow Computer,
Recorders, Product group: Level
Components
Benefit:
• Guided micro impulses are unaffected
Systems/Solutions Industry: Chemical industry, by dust and dimension
Primaries • Reliable measuring even while filling
Installed at: Kömmerling,
Pirmasens, Germany
Flow Challenge:
• Level measurement in different chemicals
Level
Environment:
• Media: chemicals
Analysis
• HCL 4% + H2O
• NACL 16 % + H2O NACO3 27% + H2O
Pressure • NACO2 22% + NAOH 4% + H2O
• Water
Temperature
Solution:
Gamma • Micropilot M:
• 6 FMR245
Flow Computer, • 2 FMR 240
Recorders, Product group: Level
Components • Process connection flange DN 50 PN
Industry: Chemical industry
Systems/Solutions Benefit:
Installed at: Solvav, Portugal • chemical compatibility
accurate metering
Flow Challenge:
• Detecting the signals from the capacitive
Level
probes in chemical tanks
Environment:
Analysis
• The transmitters are mounted in this station
to operate them from central place.
Pressure
Solution:
Temperature
• Electronic station with Level transmitter
Silometer FMC.
Gamma
Flow Computer,
Recorders,
Components
Systems/Solutions
Product group: Level
Industry: Power
Flow Challenge:
• Replacement of bubbler DP system
Level • Replacement of FMR245
• Extensive build up (polymerisation)
Analysis
Environment:
Pressure • 105 Degrees C , 10mBarG
• Sulphuric Acid, Ammonium Sulphate,
Temperature Water, Methylmethacrylate & Methacrylic
Acids Mixed
Gamma
Solution:
Flow Computer,
Recorders, • FMR255 Fieldtest
Components
Flow
Level
Analysis
Pressure
Temperature
Gamma
Flow Computer, Lucite International are one of the worlds leading suppliers of
Recorders, Methacrylates. These resins and polymers are used in many
Components industries and contain well known brands such as Perspex.
The application detailed is a by product of the manufacturing
Systems/Solutions
Process used on site and is the feedstock for further production.
The main problem seen on site is polymerization, with Perspex
stalegtites forming on the silo roof and tar formation on the liquid
surface reducing any reflected signal from the Level transmitter.
Gamma
Flow Computer,
Recorders,
Components
Systems/Solutions
Analysis
Flow Challenge:
• Accurate measurement of pH value is
necessary for good product quality. Two
Level
phase production process. Measurement
of pH in both phases.
Analysis
Environment:
Pressure • Process carried out at amb. Temperature
and 3 bar pressure.
Temperature
Solution:
• CPS 71
Gamma • CPA471
Flow Computer,
• Topcal S
Recorders,
Components Benefit:
Product group: Analysis
• Accurate measurements
Systems/Solutions
• Exclusion of human factor
Industry: Chemical Industry
• Less maintenance
• Better product quality
Installed at: Procter & Gamble, Italy
Flow Challenge:
• The pH measurement in this TiO2 pulp is decisive
for the final product quality. Customer was used to
Level change the electrodes from Foxboro every month
because of the highly abrasive media. Each of the 4
reactors work with two measuring units. The
Analysis customer had to invest only for the substitution of
the units roundabout 30k USD, not considering the
constant maintenance of the electrodes.
Pressure Environment:
• Very corrosive.
Temperature Solution:
• CPC 300, fully automatic cleaning and calibration
system.
Gamma
Pressure
Temperature
Gamma
Flow Computer,
Recorders,
Components
Systems/Solutions
Analysis
Pressure
Temperature
Gamma
Flow Computer,
16x customized
Recorders, retractable assemblies
Components
Flow • Process:
Batch process
Level
strong acid pH, sometimes pH > 10
temperature 75 - 85 °C
Flow
Company: Bayer DyStar, Brunsbüttel
Industry: Chemical, dye production
Level
E+H responsible: Dr. Einar Möller, Dr. Martin Freudenberger
Analysis Equipment:
Sensor: CPS41-2BC6ESS
Topcal: CPC310, ex version with single ex approval (TÜV),
Pressure
special NAMUR relay configuration
Assembly: Customer owned with pneumatic limit switches
Temperature
Application: Production of different dyes in aqueous
solutions, batch process in tank
Gamma
Process conditions:
Flow Computer, pH: typically pH 2
Recorders, Temperature: 40°C – 50°C
Components Installation location: Production hall
Systems/Solutions Installed since: January 2006
Flow
Company: DOW Chemical, Stade
Industry: Glycol production
Level
E+H responsible: Dr. Einar Möller, Dr. Martin Freudenberger
Analysis Equipment:
Sensor: CPS11-2BA4ESA
Topcal: CPC310-A001B0A021A in plastic housing
Pressure
Assembly: CPA474-E1A3A2H4
Temperature Application:
Waste water: Waste water of glycol production
Gamma Process conditions:
pH: 1
Flow Computer, Temperature: 120°C
Recorders, Installation location: Outside, close to industrial waste
Components water treatment plant
Flow Challenge:
• Brakish water is used for production of
ultrapure water by combination ion
Level
exchange and reverse osmosis
Organic components in the raw water
Analysis would lead to fouling at the RO-
membranes.
Pressure Environment:
• Sea shore
Temperature
Solution:
• CSM 750-7A1A
• CSS 70-A1B3A with Titan head
Gamma
Pressure
Flow Challenge:
• Monitoring the process pressure of
Level different chemicals
Environment:
• Formophenolic resins are produced here
Analysis
for floor and wall coverings made of
plastic
Pressure Solution:
• Several Cerabar S are used to monitor
Temperature the pressure of format, catalysus and
cooling water
Gamma
Aluminium products
Flow Challenge:
• Surface treatment and anodizing
Level of aluminium products
• ... for the cosmetics,
Analysis pharmaceutical and automotive
industries.
Pressure
Solution:
Temperature • Pressure measurement of
chemicals (acids and alkalis) with
Gamma Cerabar S (ceramic sensor).
Flow Computer,
Recorders, Product group: Pressure
Components
Industry: Chemical industry, Pharma
Systems/Solutions
Installed at: France
Ammonium hydroxide
Flow Challenge:
• Head pressure
Level measurement of
ammonium hydroxide
Analysis
Environment:
Pressure • 100°C temperature
• 1 bar pressure
Temperature
Solution:
Gamma • Cerabar
Flow Computer,
Recorders,
Components
Product group: Pressure
Systems/Solutions
Industry: Chemical industry
Temperature
Flow
Level
Analysis
Pressure
Temperature
Gamma
Flow Computer,
Recorders,
Components
Systems/Solutions
Flow
Level
Analysis
Pressure • Application
Temperature
• Solution
Gamma
Flow Computer,
• Design
Recorders,
Components
Systems/Solutions
Level TMT182
HART head transmitter
Analysis
Pressure
Temperature
Gamma
Flow Computer,
Recorders,
Components
Systems/Solutions
8 mm Ø bore.
and Sensor Removal
52 mm Ø
Flow
Thermocouple
mm Ø
Without Disconecting Wiring. Duplex Type `K` Class 1
1/4" NPT St. Steel Insulated Hot Junctions.
1" NPT x 1/2" NPT Compression Fitting.
45.20
45.57
C / Steel Reducer 1" NPT.
Epoxy Painted.
Level
30 mm Ø
Analysis
ROTATE
REMOVE
1.5 mm thick
Fixed Duplex Screw Type Stellite Coated.
Ceramic Terminal Block
with Metal Holding Plate.
10 mm
+
Cable Entry.
+
Temperature Wired on St.Steel
Tag Plate.
Four Terminals
RTD
Connection. Each with Dual Screws.
Components
Floats Road • Incoloy 800H Flange, 2” 600lb RF
Manchester M23 9NF
Tel : +44 (0) 161 286 5100
England
FAX : +44 (0) 161 286 5093
J.K.Khushu
Reliance Industries Ltd
/ Thermowell Design
( Exploded View )
Systems/Solutions
• For product flow with high erosion at 450°C - 500°C
• Insert 6mm INCONEL 600 sheathed MI Thermocouple
• Duplex type K, Class 1 Thermocouple
Flow 25 mm 75 mm
Radiant Shield
Inconel 600
4" long Tubes.
35 mm Ø bar
Inconel 600.
1/4" NPT St. Steel
1" NPT x 1/2" NPT Compression Fitting.
C / Steel Reducer
Level
1" NPT.
Epoxy Painted.
Flamepath Collar 8 mm
& `O` Ring Seal.
Pressure
Forged St. Steel Union. 2" Sch 10
4 - 20 mA Transmitter. 3 - M6 Hex. Headed Bolts Thermocouple
Equally Spaced. Single Type `K` Class 1
Insulated Hot Junction. 3" Sch 10
M20 x 1.5
Cable Entry. + - Incoloy Flange 4" Sch 10
Size & Rating as Required.
Temperature Transmitter 3
4 5
6
Ceramic Cement.
6 mm o.d. x 4 mm i.d.
High Purity Alumina Tube.
25 mm
5 mm
Wiring Diagram
35 mm Ø
25 mm Ø
Gamma
10 mm Ø
15 mm Ø
6.5 mm Ø
10 mm Ø
bore.
bore.
4 off Holes
TDL.4302 / 0 1 of 1
Systems/Solutions
• Pipe measurement containing exit gas flow at 1100°C
• Radiation shield to measure the real gas temperature
• Isolated thermocouple inside the thermocouple (ceramic cement insulation)
Flow
Level
Analysis
Pressure
Temperature
Gamma
Flow Computer,
Recorders,
Components
Systems/Solutions
Level
Analysis
Pressure
T/C 10
T/C 11
T/C 12
T/C 6
T/C 1
T/C 2
T/C 3
T/C 4
T/C 5
T/C 7
T/C 8
T/C 9
Temperature 1686 2536 3386 4236 5086 5936 6786 7636 8486 9336 10186 11036
1700
Gamma 434
1/2" 300lb RF Flange
11036 30 38 100
Flow Computer,
Incoloy 800H.
Reinforcement.
F
Recorders, B
Components
F 12 Ø hole with
3 mm 6 Ø St. Steel
Detail `D` 1 1/2" x 1 1/2" x 1/2" Sch 160 Support Rod. 3 Ø vent hole.
Pot Seals. Thermocouple Tubes
Systems/Solutions
Reducing Tee
Bundled together through End Cap Sch 160
150 Ø x 20 thick Incoloy 800H. 1 Detail `D`
Full Penetration Strengthening Section.
Box Flange. 8 9 10 2 Incoloy 800H.
Weld. 7 3
1 1/2" 300lb RF Flange 1 1/2" 300lb RF Flange 6 11 12 4 Section F - F 12 Off Thermocouples
5
316 St. Steel. Incoloy 800H. 3 mm Ø 316 St. Steel Sheathed
Section A - A Mineral Insulated
ZAG 12 Enclosure IP67
A Single Type `K`
DieCast Aluminium Insulated Hot Junction.
260 x 160 x 90. 22 26
T/C 12
5 Off
20 mm Cable Entries 3 thick
+
+
-
Klippon Type Sealed with Plugs. 316 St. Steel Spacer Discs. 11036
35 SAK 4 Terminals
Mounted on 25
35
1
C 8 2 B
9 10
7 3 1 1
35
11 12 8 9 10 2 8 9 10 2
6 4 7 3 7 3
1 1/2" NPT. 5 6 11 12 4 6 11 12 4
35
5 5
+
-
E
Slide 58 Endress+Hauser Consult AG Sales Support
View on B
with Lid Removed
Section D - D D Section E - E 1.5 thick
316 St. Steel Spacer Disc.
View on C A View on B
211709
Applications in the chemical industry
Flow Engineering:
Level
Analysis
Pressure
Temperature
Gamma
Flow Computer,
Recorders,
Components
Project: SPA PROJECT
Systems/Solutions
Contract: 1-15-0524A Units: DIMER
Ord.: PP0032/1.15.0524A
Job: 94470
Mat. Req.: 0524A-1611C/01; 1611F/01
Flow 12 M
Level
3M
A 18 off
ASTM A182 F316 1 1/2" o.d. Tubes.
B
Mounting Frame. Special Multipoint Probe.
Sheath - Inconel 600, 6.35 mm o.d., 0.66 mm wall thickness , 16 M overall length
1 `K` positive and 5 `K` negative wires , MgO Insulated
All Insulated Hot Junctions
( M.I. Shipped in 610 mm Coil - Sheath bendable round a 50 mm or larger mandrel )
Pressure
1 mm Ø `K` + ve
Temperature Terminals.
Mounting Brackets.
6 off
View on B
M24 x 1.5 St. Steel
Wiring Compression Fittings.
Diagram
Components
St. Steel
Junction Box
with Lid rremoved.
Pot Seal 45 mm long x 15 mm Ø
Epoxy Filled.
Systems/Solutions
• Each
Thermo thermocouple
Devices Limited has 5 measuring points L.Blount
20thSept`00
General Layout & Details of
18 off 5 Point Reactor
Floats Road Manchester M23 9NF England
Thermocouple Assemblies.
• The thermocouples are guided in “guiding tubes”
Tel : +44 (0) 161 286 5100 FAX : +44 (0) 161 286 5093
TDL.4055 / 0 1 of 1
Pressure
Temperature
Gamma
Flow Computer,
Recorders,
Components
Systems/Solutions
Gamma
Flow Challenge:
• Continuous level measurement
Level • Sold as turn key projects
Analysis
Environment:
• Process pressure max. 1 bar
• Process temperature app.200°C
Pressure
Solution:
Temperature
• 2 pcs. Source container QG020
• 1 pcs. Detector DG 57
Gamma • 1 pcs. Transmitter FMG 671
Flow Computer,
Recorders,
Components
Product group: Gammapilot Benefit:
Systems/Solutions • Easy installation
Industry: Chemical industry • Non contact
• Maintenance free
Installed at: Yosu, Korea
Flow Challenge:
• Continuous level measurement by
Level absorption
• High activity with best screening
Analysis
Environment:
• Process pressure max. 30 bar
Pressure • Process temperature app. 250°C
Temperature
Solution:
• 2 pcs. Source container QG 2000
Gamma • 2 pcs. Detector DG 57
• 2 pcs. Transmitter FMG 671
Flow Computer,
Recorders,
Components Product group: Gammapilot
Benefit:
Systems/Solutions Industry: Chemical industry • Easy installation
• Continuous level control
Installed at: FCFC, Taiwan • Maintenance free
Flow
Level
Analysis
Pressure
Temperature
Gamma
Flow Computer,
Recorders,
Components
Systems/Solutions
Flow Challenge:
• Continuous level measurement
• High activity with best screening
Level
Environment:
Analysis
• Process pressure max. 15 bar
• Process temperature app. 250°
Pressure
Solution:
Temperature
• 1 pcs. Source container TSP16636
• 14 pcs. Detector DG 57
Gamma • 14 pcs. Transmitter FMG 671
Flow Computer,
Recorders, Product group: Gamma pilot
Components Benefit:
Industry: Chemical industry • Under extreme condition the measuring
Systems/Solutions
task have been solved
Installed at: FCFC, Taiwan
Flow Challenge:
• Continuous level measurement
• Thick wall of vessel
Level
Environment:
Analysis
• Process pressure max. 10 bar
• Process temperature app.200°C
Pressure
Temperature
Solution:
• 2 pcs. Source container TSP16636
• 8 pcs. Detector DG57
Gamma • 8 pcs. Transmitter FMG671
Flow Computer,
Recorders,
Components Product group: Gammapilot Benefit:
• Two detectors in parallel for higher
Systems/Solutions sensitivity
Industry: Chemical industry
• 8m continuous level control
Installed at: Xiamen, China • Maintenance free
• Installation during operation, no shut down
Flow
Level
Analysis
Pressure
Temperature
Gamma
Flow Computer,
Recorders,
Components
Systems/Solutions
PE powder
Polyester - Esterification
Flow Application
Level measurement in the
Level
Esterification reactor esterification reactor OR
vapor separator
Analysis
Vapor
Pressure separator
Temperature
Gamma
Flow Computer,
Recorders,
Components
Systems/Solutions
Polyester - Finisher
Flow
Application
Level measurement in the finisher at the
Level
inlet as well as in the outlet.
Level at the inlet and outlet are related to the
Analysis viscosity of the product.
Pressure Advantages
• Non invasive
Temperature
• Installations have no influence
Gamma • Free of maintenance
Flow Computer,
Recorders,
Components
Systems/Solutions
Flow
Application
Level measurement below the shaft
Level up to the minimum.
The rotation direction in
Analysis combination with the configuration
of the measurement devices is
necessary for the
Pressure
functionality.
Temperature
Gamma
Flow Computer,
Recorders,
Components
Systems/Solutions
Flow Challenge:
• Recording emission of chlorine gas
(for production of surgical gloves -
Level
health care products)
Analysis Environment:
• 15 distributed chlorine gas sensors
Pressure • Evidence for local inhabitants
• Environmental protection
Temperature
Solution:
Product group: Registration • Memo Graph RSG10-BxxxA2xBA
Gamma
Industry: Chemical industry
Flow Computer,
Recorders, Benefit:
Installed at: Malaysia
Components • 16 measurement inputs, low channel price
• Signal analysis: Display of max, min and
Systems/Solutions
average values over defined time on request
• Data storage makes the past present
• Reliable without pens and paper