Contents
2
Setting Up a Cell and Public Channels
RNC Node B UE
10
Strategy of Cell Selection and Reselection
To B
© ZTE All rights reserved 12
Cell Selection and Reselection (B)
From A
Qqualmeas : Measured cell quality value. The quality of the received signal
expressed in CPICH Ec/No (dB).
Qrxlevmeas : Measured cell RX level value. The quality of the received signal
expressed in CPICH RSCP (dBm).
Qqualmin : Minimum required quality level in the cell (dB).
Qrxlevmin : Minimum required RX level in the cell (dBm).
Pcompensation : max(UE_TXPWR_MAX_RACH - P_MAX, 0) (dB)
UE_TXPWR_MAX_RACH : Maximum TX power level on RACH (dBm)
P_MAX : Maximum RF output power of the UE (dBm)
Select and monitor the indicated PICH and PCH of the cell
according to information sent in system information.
Monitor relevant system information.
Perform necessary measurements for the cell reselection
evaluation procedure.
Execute the cell reselection evaluation process.
P-CPICH Treselections
Ec/Io
Serving Cell Qmeas,s + Qhyst2s Serving Cell
Qqualmin +
SIntraSearch
Qmeas,n - Qoffset2s,n
Qqualmin
Neighboring Cell
Neighboring
cell criterion S
is fulfilled and is
ranked Neighboring Cell
Quality/ Treselections
Rx Lev
UMTS Qmeas,s + Qhyst1s GSM Serving
Serving Cell Cell
Qqualmin +
SSearchRat
Qmean,n – Qoffset1s,n
QRxLevMin
Inter-RAT cell
GSM criterion S is
UMTS
Neighboring Cell fulfilled and is
Neighboring Cell
ranked
Yes
Parameter QualMeas
Name
Description This parameter indicates the quality measure type for
cell selection and reselection.
Range and Step 1: CPICH Ec/No
2: CPICH RSCP
Default Value 1
Configuration View->Configuration Management->ME>UMTS logic
Path function configuration->UltranCell->Cell Selection and
Reselection information->UltranCellXXX-
>Measurement Quality for Cell Selection and
Reselection
Parameter QQualMin
Name
Description This parameter indicates the minimum required quality level of
the cell which satisfies the condition of being selected or
reselected by UE. When the quality measure is CPICH Ec/No, only
when the measured quality of the cell is over Qqualmin then the
cell could be selected. It’s -18dB by default.If value of the
parameter is increased, it’s harder for the cell to satisfy the
condition of being selected. If value of the parameter is
decreased, it’s easier for the cell to satisfy the condition of
being selected.
Range and Step [ 1 , 16 ] dB step 1dB
Default Value 16dB
Configuration Path View->Configuration Management->ME>UMTS logic function
configuration->UltranCell->Cell Selection and Reselection information-
>UltranCellXXX->Qqualmin-offset
Parameter SIntraSearchPre
Name
Description This parameter is a switch indicating whether Sintrasearch is
configured or not. If the value is False, Sintrasearch is not
configured to UE and UE performs periodical intra-
frequency measurement. If the value is True, Sintrasearch is
configured to UE, and UE judges whether to perform the
intra-frequency measurement.
Range and Step False: Not configured to UE.
True: Configured to UE.
Default Value True: Configured to UE.
Configuration View->Configuration Management->ME>UMTS logic function
Path configuration->UltranCell->Cell Selection and Reselection
information->UltranCellXXX-> Sintrasearch Configuration
Tag
Parameter SInterSearchPre
Name
Description This parameter is a switch which indicates whether
Sintersearch is configured or not. If the value is False, Sintersearch
is not configured to UE and UE performs periodical inter-
frequency measurement. If the value is True, Sintersearch is
configured to UE, and UE judges whether to perform the
inter-frequency measurement.
Range and Step False: Not configured to UE.
True: Configured to UE.
Default Value True: Configured to UE.
Configuration View->Configuration Management->ME>UMTS logic
Path function configuration->UltranCell->Cell Selection and
Reselection information->UltranCellXXX->Sintersearch
Configuration Tag
Parameter OtherRATInfoPre
Name
Description This parameter is a switch indicating whether inter-RAT
information parameters used for cell reselection are configured
or not. If the value is False, inter-RAT information parameters are
not configured to UE and UE performs periodical inter-RAT
measurement. If the value is True, inter-RAT information
parameters are configured to UE, and UE judges whether to
perform the inter-RAT measurement.
Range and Step False: Not configured to UE.
True: Configured to UE.
Default Value True: Configured to UE.
Configuration Path View->Configuration Management->ME>UMTS logic function
configuration->UltranCell->Cell Selection and Reselection
information->UltranCellXXX->Inter-System Information
Configuration Tag
Parameter Qhyst2s
Name
Description This parameter indicates the hysteresis value for FDD cells in case the
quality measure for cell selection and reselection is set to CPICH Ec/No. In
cell-ranking criterion R of cell reselection, the R value of serving cell
equals to the measured value plus Qhyst2 s. If value of the parameter is
increased, it’s harder to trigger cell reselection as the R value of the
serving cell will increase. If value of the parameter is decreased, it’s
easier to trigger cell reselection as the R value of the serving cell will
decrease.
Range and Step [ 0 , 40 ] dB step 2dB
Default Value 2dB
Configuration Path View->Configuration Management->ME>UMTS logic function
configuration->UltranCell->Cell Selection and Reselection information-
>UltranCellXXX->Reselection Hysteresis 2 of Serving Cell (QHyst2s)
Parameter Treselections
Name
Description This parameter indicates the cell reselection timer value. UE will reselect
the new cell if the new cell is best ranked according to the criterion R
during a time interval indicated by Treselection and the new cell can be
selected as new serving cell only after extension of the reselection timer.
If value of the parameter is increased, it’s harder to trigger cell
reselection. If value of the parameter is decreased, it’s easier to trigger
cell reselection.
Range and Step [ 0 , 31 ] s step 1s
Default Value 1s
Configuration Path View->Configuration Management->ME>UMTS logic function
configuration->UltranCell->Cell Selection and Reselection information-
>UltranCellXXX->Cell Reselection Timer Value (Treselections)
Parameter CellBarredInd
Name
Description This parameter is cell barred indicator. If the cell barred
indicator is set to “Barred”, UEs are not permitted to
select/re-select this cell, even for emergency calls.
Range and Step 1: Barred
2: Not Barred
Default Value 2: Not Barred
Configuration View->Configuration Management->ME>UMTS logic
Path function configuration->UltranCell->Cell Selection and
Reselection information->UltranCellXXX->Cell Barred
Indicator
Parameter InFreqReselInd
Name
Description This parameter is intra-frequency cell reselection indicator. If cell
is barred, if the value of this parameter is “Allowed”, UE is
allowed to select other intra-frequency cell in case it satisfies the
cell selection/relection condition. If it is set “Not Allowed”,
when cell is barred, UE will not select another intra-frequency
cell.
Range and Step 0: Allowed
1: Not Allowed
Default Value 0: Allowed
Configuration Path View->Configuration Management->ME>UMTS logic function
configuration->UltranCell->Cell Selection and Reselection
information->UltranCellXXX->Intra-frequency Cell Reselection
Indicator
Parameter Sib11orSib11bis
Name
Description This parameter indicates UTRAN neighbour cells are
broadcasted in either SIB11 or SIB11bis, the default
parameter is SIB11. If there are so many neighbour cells,
and the size of system message larger than 3552bit,
select part of cells broadcast in SIB11bis
Range and Step 0: SIB11
1: SIB11bis
Default Value 0: SIB11
Configuration View->Configuration Management->ME>UMTS logic
Path function configuration->UltranCell->adjacent relation
configuration->Neighbouring cell->Broadcast in either
SIB11 or SIB11bis
Parameter MeasPrio
Name
Description This parameter indicates the measurement priority of the
neighboring cell. The smaller value it is, the higher
priority the cell has.
Range and Step [0,2]
Default Value 0
Configuration View->Configuration Management->ME>UMTS logic
Path function configuration->UltranCell->adjacent relation
configuration->Neighbouring cell->Measurement
Priority of Neighboring Cell
40
Strategy of LA and RA Update
NAS Connection
47
Strategy of URA Update
If the new cell that the UE camps on is not in the same URA area
as the former cell that the UE camps on, the URA Update is
triggered.
The UE enters a cell that has no URAs defined. This will trigger a
release of the RRC Connection and the UE enters Idle mode.
UE UTRAN
URA UPDATE
UE UTRAN
URA UPDATE
50
Strategy of CELL Update
CELL UPDATE
CELL UPDATE
UE UTRAN
PHYSICAL CHANNEL RECONFIGURATION COMPLETE
CELL UPDATE
RADIO BEARER
RECONFIGURATION COMPLETE