3 Fmea
3 Fmea
On
Failure Mode Effect Analysis - FMEA
(Refer : FMEA AIAG Manual - 4th Edition)
Process FMEA
Steps to do FMEA
Recommended Actions
Example PFMEA
2
Introduction
3
WHAT IS FMEA ?
FMEA is an acronym that stands for Failure Modes and Effect
Analysis.
5
When PFMEA Required?
• New process being designed
• New equipment developed or purchased
• Existing process being designed or redesigned
• To monitor and track improvement over time
6
Types of FMEA
System
Focus is on functions and interactions among systems.
Design
Focus is on potential failure modes of products due to
design deficiencies and errors.
Process
Focus is on potential failure modes caused by process
deficiencies.
7
FMEA Team
Team approach is necessary
Examples of team representatives:
- Design
- Manufacturing Operators/Supervisors
- Quality
- Reliability
- Materials
- Testing
- Supplier
- Customers
8
FMEA Inputs and Outputs
Inputs Outputs
Actions designed to
Process Flow diagram
prevent failures or detect
effects.
Characteristics Matrix
History of imp. project
Control Plan for existing FMEA under-taken
product
Input to control Plan
Customer
Requirements
9
Definition of Terms
Failure: A ‘Failure’ is that a component, assembly or system which does
not meet the requirements or function in accordance with design intent.
(Ex. Not meeting the specification, heat treatment failure)
Failure Mode - the way in which a specific process input fails - if not
detected and either corrected or removed, will cause Effect to occur. Can
be associated with a defect (in discrete manufacturing) or a process input
variable that goes outside of specification.
Effect - impact on customer requirements. Generally external customer
focus, but can also include local effect or downstream processes. Can be
product or process.
Cause
- Sources of process variation that causes the Failure Mode to occur.
For example, for the Failure Mode, Temperature too High, the Cause
might be a faulty temperature sensor.
- Identification of Causes should start with Failure Modes associated
with the highest severity ratings.
10
Definition of Terms - continued
Current Controls
- Systematized methods/devices in place to prevent or detect failure modes
or Causes (before causing effects).
- Prevention consists of foolproofing, automated control and set-up
verifications
- Controls consists of audits, checklists, Inspection, laboratory testing,
training, SOP’s, preventive maintenance, etc.
Severity (of Effect)- importance of effect on customer requirements - could also
be concerned with safety and other risks if failure occurs (1=Not Severe,
10=Very Severe)
Occurrence (of Cause)- frequency with which a given Cause occurs and creates
Failure Mode. Can sometimes refer to the frequency of a Failure Mode (1=Not
Likely, 10=Very Likely)
Detection (capability of Current Controls) - ability of current control scheme to
detect:
- the causes before creating failure mode
- the failure modes before causing effect
- 1=Likely to Detect, 10=Not Likely at all to Detect
RISK PRIORITY NUMBER (RPN) is multiplication of severity , occurrence &
detection
i.e. RPN = Severity X Occurrence X Detection
11
Process FMEA
12
Process
Customer
Next
Inputs PROCESS Outputs
Operation
OEM ASSY USER
Human Infra
Resources Structure
- Equipment
- Tooling etc.
PROTOTYPE/PRELAUNCH/PRODUCTION
CUSTOMER :
Step-1 Step-2 SUPPLIER CODE VEHICLE / MODEL DOC. NO.
PART NO./REV. NO. CUSTOMER : SUPPLIER : PART NAME DATE(ORIG)
ASSY. NO./REV.NO. CUSTOMER : SUPPLIER : ASSY. NAME REV NO / DATE
CORE TEAM : PROCESS RESPONSIBILITY DVM P.E.
RESP./
C
POTENTIAL CURRENT CURRENT TARGE
PROCESS POTENTIAL S L O D R S O D R
POTENTIAL CAUSE(S) PROCESS PROCESS RECOMMENDED T ACTION
OPN.NO. FUNCTION EFFECT(S) OF E A C E P E C E P
FAILURE MODE V MECHANISM(S) OF C CONTROL CONTROL T N ACTIONS COMPL TAKEN V C T N
REQUIREMENT FAILURE S
FAILURE PREVENTION DETECTION ETION
Step-3 Step-4 S
Step-7 Step-8
DATE Step-9
Step-5 Step-6
16
STEPS to do FMEA
• Step 1 - Select a process to evaluate
• Step 2 - Recruit a multidisciplinary Team
• Step 3 - Have the team meet to list all the steps in the process
• Step 4 - Have the team list failure modes and causes
• Step 5 - For each failure mode have the team assign likelihood of
occurrence, likelihood of detection and severity.
19
Suggested PFMEA Severity Evaluation Criteria
Contd…
Suggested PFMEA Severity Evaluation Criteria (Continued)
Moderate Vehicle/ item operable but Comfort/ Or a portion (less than 100%) of the product
convenience item(s) inoperable. may have to scrapped with no sorting, or 6
Customer dissatisfied. vehicle/ item repaired in repair department with
a repair time less than a half-hour.
Low Vehicle/ item operable but comfort/ Or 100% of product may have to be reworked,
convenience item(s) operable at a or vehicle/ item repair off-line but does not go to 5
reduced level of performance. repair department.
Very low Fit and finish/ squeak and rattle item Or the product may have to be sorted, with no
does not conform. Defect noticed by scrap, and a portion (less than 100%) reworked. 4
most customers. (greater than 75%)
Minor Fit and finish/ squeak and rattle item Or a portion (less than 100%) of the product
does not conform. Defect noticed by may have to be reworked, with no scrap, on-line 3
50% of customers. but out-of-station.
Very minor Fit and finish/ squeak and rattle item Or a portion (less than 100%) of the product
does not conform. Defect noticed by may have to be reworked, with no scrap, on-line 2
discriminating customers (less than but in-station.
25%)
None No discernible effect. Or slight inconvenience to operation or
operator, or no effect. 1
Suggested PFMEA-Occurrence evaluation criteria with Ppk values
Very High : Persistent Failure > 100 per thousand pieces. < 0.55 10
Low : Relatively Few Failures 0.5 per thousand pieces. > 1.20 3
Very remote Controls will probably not detect. X Control is achieved with indirect or random checks 9
only.
Remote Controls have poor chance of detection. X Controls is achieved with visual inspection only. 8
Very low Controls have poor chance of detection. X Control is achieved with double visual inspection only. 7
Low Control may detect. X X Control is achieved with charting methods, such as 6
SPC {Statistical Process Control}.
Moderate Controls may detect. X Control is based on variable gauging after parts have 5
left the station, or Go/No Go gauging performed on
100% of the parts after parts have left the station.
Moderate Controls have a good chance to detect. X X Error detection in subsequent operations, or gauging 4
high performed on setup and first-piece check (for set-up
causes only).
High Controls have a good chance to detect. X X Error detection in-station, or error detection in 3
subsequent operations by multiple layers of
acceptance : supply, select, install, verify. Cannot
accept discrepant part.
Very high Controls almost certain to detect. X X Error detection in-station (automatic gauging with 2
automatic stop feature). Cannot pass discrepant part.
Very high Controls certain to detect. X Discrepant parts cannot be made because item has 1
been error proofed by process/ product design.
Inspection Types:
A. Error-proofed
B. Gauging
C. Manual Inspection
Suggested PFMEA RPN Evaluation Criteria
• RPN = (S) x (O) x (D)
26
HMSI-Suggested PFMEA RPN Evaluation Criteria
• RPN = (S) x (O) x (D)
12 oz in cup Cup
Great Taste Brewed Coffee
- Strength
- Color
- Temperature
- Freshness
Example-PFMEA - Making Coffee
S O D R p
r
E C E P p p p p
Part/Process Failure Mode Failure Effects V Causes C Controls T N Actions Plans S OD n
Install Filter Not Installed Coffee grounds in pot 5 Operator 2 Work Instructions 2 20 0
Operator T raining 2 20 0
Filter package
Wrong T ype Coffee grounds in pot 5 mislabled 1 None 5 25 0
Filter package
None 1 mislabled 1 None 5 5 0
T oo many filters
installed None 1 Filters stuck together 3 Filter T exture 4 12 0
Operator T raining 3 9 0
Filter Skewed/Folded
Over Coffee grounds in pot 5 Operator 3 Operator T raining 3 45 0
Work Instructions 2 12 0
Did not level after
measuring 3 Operator T raining 2 18 0
Different coffee brand 4 Recipe 2 24 0
Measuring tool by
T oo litt le coffee weak coffee 3 wrong measuring tool 2 coffee equipment 1 6 0
Work Instructions 2 12 0
Didn't fill measuring
tool full 3 Operator T raining 2 18
Different coffee brand 4 Recipe 2 24 0
Determine if
premade filter and
coffee packets are
available, cost Julie - 3/17/98:
effective, and taste Report at next
0 acceptable meeting 1 1 1 1
30