You will consider the various area classifications relating to the
probability of release of gases and the likelihood of danger from
such release.
You will also consider temperature classifications of equipment in
terms of their temperature and the categories for operation in
explosive environments.
3
AREA CLASSIFICATION
4
Hazardous areas are classified by gas groups and zones.
▰ Zones are used to define the probability of the presence of flammable materials.
▰ Gas Groups consider the ignition energy of the substance and focuses on
ignition from a spark source.
5
IEC 60079-10
Area classification is a method of
analysing and classifying the
environment where explosive gas
atmospheres may occur.
6
IEC 60079-10
This will facilitate the proper selection and installation of apparatus to be
used safely in that environment, taking into account gas groups and
temperature classes.
7
To determine the Area Classification :
Assemble pertinent information
▰ Codes, standards, practices, and references
▰ Process and operating descriptions
▰ Process flow diagrams (PFDs) and material and heat balance charts
▰ Piping and instrumentation diagrams (P&IDs)
▰ Equipment arrangement drawings and plot plans
▰ Commissioning, testing, operating, and safety procedures.
8
To determine the Area Classification (Continued)
▰ List all flammable and combustible materials, along with their pertinent
properties, such as ignition temperatures and flash points.
▰ Confirm the need for classification by assessing the likelihood of the
presence of flammable and combustible materials.
▰ Locate material release sources, such as:
▰ Open process points, Control valves, Pump seals, Drains, Metering
points, Sampling points, Vents, etc.
9
UNDERSTANDING ZONES
10
Zone Classification
The zone defines the probability of hazardous material being present in an
ignitable concentration in the surrounding atmosphere.
11
The important factors that must be considered for zone classification are:
▰ The probability of the presence of gas or vapour
▰ The quantity of the gas or vapour present in the area
▰ The duration of the gas or vapour present in the area
12
The amount of ventilation present in the area
▰ The nature of the gas. i.e. whether it is lighter or heavier than air
▰ The consequence of an explosion and possible chain reaction
13
Zone 0 is generally found inside tanks or vessels containing flammable liquids.
14
Zone 0
An area in which an explosive gas-air mixture is
present continuously, for long periods or
frequently.
> 1000 hours or more in any given year.
15
Zone 0 gives rise to a Zone 1 as the tank vent is a primary source of release
Zone 1
16
Zone 1
An area in which an explosive atmosphere is
likely to occur for short periods in normal
operation.
10 - 1000 hours in any given year.
17
Zone 1 gives rise to a Zone 2
18
Zone 2
An area in which an explosive atmosphere is not
likely to occur in normal operation, but if it does
occur, will persist for only a short period.
0 - 10 hours in any given year.
19
Explosive Atmosphere
Total hours an explosive atmosphere will exist in any given year.
Zone 0 Zone 1 Zone 2 Zone 0 = 1000 hrs or more.
Zone 1 = 10 - 1000 hrs.
Zone 2 = 0 – 10 hrs.
Red zone explosive atmosphere:
Yellow zone no explosive
atmosphere present:
20
Explosive Atmosphere
Where different zones are created by different sources of release and they
overlap the higher risk of zone will apply in the area.
21
Explosive Atmosphere
Zone 0 An area in which an explosive gas-air
mixture is present continuously, for long
periods or frequently.
Zone 1 An area in which an explosive gas-air mixture
is likely to occur for short periods or
occasionally in normal operation.
Zone 2 An area in which an explosive gas-air mixture
is not likely to occur, and if it occurs it will
only exist for a very short time due to an
abnormal condition.
22
Zone Classifications
23
RELATIVE DENSITY
24
Relative Density
A gas with a density
lighter than air will
H2
rise when released
into the atmosphere
and a gas with a
density heavier than H2S
air will fall.
25
Relative Density
Relative vapour
Material
density
Air 1
Acetylene 0.9
Butane 2.05
Ethylene 0.9
Hydrogen 0.07
Hydrogen
1.19
Sulphide
Methanol 1.11
Petroleum 2.8
26
Relative Density
▰ Lighter than air gases will rise and disperse into the air quickly.
▰ Heavier than air gases will fall and could collect at ground level, or in
sumps or drains, and remain there for long periods.
27
VENTILATION
Zone 1 due to low ventilation
28
Natural Ventilation
▰ Natural ventilation is described as the movement of air caused by the wind or
temperature gradients
▰ In open air areas, natural ventilation can assist in the dispersal of an explosive
gas atmosphere.
29
Artificial Ventilation
▰ Artificial ventilation is provided by the use of fans or extractors.
▰ Although artificial ventilation is mainly used inside a room or enclosed
space, it can also be applied to outside situations as well.
30
Ventilation
The more ventilation there is, the faster the substance will be dispersed into
the air (below the LEL) and therefore the extent of the zone will be smaller.
31
Degrees of ventilation: 3 Types
▰ (VH) High Degree of Ventilation
▰ (VM) Medium Degree of Ventilation
▰ (VL) Low Degree of Ventilation
32
Availability of Ventilation: 3 Types
▰ Good: Ventilation is present continuously
▰ Fair: Ventilation is expected to be present during normal operations.
▰ Poor: This is where there is no continuous ventilation and breaks
happen often.
33
Ventilation can alter the zone.
▰ Ventilation: Type: Natural
Degree: Medium
Availability: Good
34
Ventilation can alter the zone.
▰ Ventilation: Type: Artificial (Natural)
Degree: Low (Medium)
Availability: Fair (Good)
35
36
GRADING OF GAS RELEASE
▰ Sources of Release:
The point from which a flammable gas, vapour or mist can be released into
the atmosphere.
37
Grading of Gas Release
Every item of process equipment should be considered as a potential source
of gas release.
38
Continuous Grade of Release
Zone 0
▰ The surface of a flammable liquid contained in a storage tank.
▰ The surface of an open reservoir.
39
Primary Grade of Release
Zone 1
Seals of pumps, compressor or valves which would normally emit
flammable materials at particular stages of the start up cycle.
40
Primary Grade of Release
▰ Water drainage points on vessels which contain flammable liquid
▰ Outlets from which samples are drawn for analysis.
▰ Relief vents and valves which are expected to release during normal
operations
41
Secondary Grade of Release
Zone 2
Flanges, connections and pipe fittings not expected to release
Flammable materials during normal Operations.
42
Secondary Grade of Release
Seals of pumps, compressor or valves which would not be expected to emit
flammable materials during normal operations.
Relief vents and valves which are not expected to release flammable
materials during normal operations.
43
Secondary Grade of Release
44
Normal Operation
Situation when the equipment is operating within its design parameters.
Minor releases of flammable material may be part of normal operation.
45
Catastrophic Failure !
Catastrophic failure is, for example, the unforeseen rupture of a process
vessel or pipeline that in normal operation cannot be predicted.
46
Catastrophic Failure !
Once a plant has been classified and all necessary records made, it is
important that no modification to equipment or operating procedures are
made.
47
Catastrophic Failure !
Changes can be made but only after discussion with those responsible for
the area classification or a management of change (MOC) is in effect.
48
GAS GROUPS
Gases are grouped for mining and surface applications based on the amount
of energy necessary to ignite the most explosive mixture of gas with air.
49
Group I
Below ground where methane firedamp is present.
50
Group II
Above ground where explosive gas atmospheres exist.
51
Group III
Above ground where explosive dust atmospheres exist.
52
Gas Groups
Ignition
Gas Type Temperature
Group Energy
(Representation) Classification
(Approx)
Methane
I ----- 280 μJ
(Firedamp)
II Propane T1 260 μJ
II Ethylene T2 95 μJ
II Hydrogen T1 20 μJ
53
Group II is further divided into 3 Sub Divisions.
Ignition
Gas Type Temperature
Group Energy mA
(Representation) Classification
(Approx)
IIA Propane T1 260 μJ 70
IIB Ethylene T2 95 μJ 45
IIC Hydrogen T1 20 μJ 21
54
Gas Groups
IIA IIB IIC
Methane Ethylene Acetylene
Propane
Butadine Hydrogen
Petroleum
Butane Hydrogen Carbon
Sulphide Disulphide
Kerosine
55
EXPLOSIVE LIMITS
Oxygen is a key factor in making gases and vapours flammable.
If too much or too little oxygen is present, the gas/oxygen mixture will
not ignite.
The exception to this rule is Acetylene which does not require oxygen to
ignite.
56
Explosive Limits
Lower Explosive
LEL Limit
The percentage concentration of
gas in air below which the
gas atmosphere is not
explosive.
Mixture is too lean
57
Explosive Limits
Upper Explosive
UEL
Limit
The percentage concentration of
gas in air above which the
gas atmosphere is
not explosive.
Mixture is too rich 58
Explosive Limits
59
Explosive Limits
Gas Type Gas Group LEL UEL
(%) (%)
Acetylene IIC 1.5 100
Ethylene IIB 2.7 34
Hydrogen IIC 4.0 75
Methanol IIA 6.7 36
Propane IIA 2.0 9.5
60
Explosive Limits
61
Flashpoint (Definition)
Flashpoint is:
‘the minimum temperature at which sufficient vapour is given off from a
liquid, to form a flammable mixture with air that can be ignited by an arc,
spark or naked flame’.
62
Flashpoint (Definition)
Gas Type Flashpoint LEL (%) UEL
(%)
Acetylene 1.5 100
Butane -60˚C gas 1.4 9.3
Hydrogen 4.0 75
Methanol 11˚C 6.7 36
Propane -104˚C gas 2.0 9.5
63
Flashpoint (Definition)
Methanol will ignite at
11˚C
Insufficient vapour to cause
an ignition at
10˚C
64
Ignition Temperature
The minimum uniform temperature required to initiate or cause:
▰ Self-sustained combustion of a solid, liquid, or gaseous substance
(independent of any other ignition source).
▰ Sometimes called auto ignition.
65
Ignition Temperature
Gas Type Flashpoint Ignition
Temperature
Acetylene 305˚C
Butane -60˚C gas 372˚C
Hydrogen 560˚C
Methanol 11˚C 386˚C
Propane -104˚C gas 470˚C
66
Ignition Temperature
67
TEMPERATURE CLASSIFICATION
When selecting electrical apparatus for use in hazardous areas it is important to
ensure that the maximum surface temperature of the apparatus will not be greater
than the ignition temperature of the gas in the surrounding atmosphere.
68
Temperature Classification
Ignition Temperature
Typical Gas Temperature Class
Methane 595˚C T1
Ethylene 425˚C T2
Cyclohexane 259˚C T3
Diethyl Ether 170˚C T4
69
Temperature Classification
Maximum Surface
Temperature Class
Temperature
T1 450°C
T2 300°C
T3 200°C
T4 135°C
T5 100°C
T6 85°C
70
Maximum Surface Temperature
▰ This is the maximum temperature a piece of equipment will reach in
normal operation.
▰ Equipment with a T3 rating could reach a temperature of 200°c in
normal operation, but will not get any hotter.
71
Temperature Classification
Ignition Temperature
Typical Gas
Temperature Class
Butane 372˚C T2
Hydrogen 560˚C T1
Hydrogen Sulphide 270˚C T3
72
Temperature Classification
Typical Gas Ignition
Temperature
Diethyl Ether 170˚C
Typical Gas Maximum
Temperature
Surface
Class
Temperature
Diethyl Ether T4 135°C
73
74
Ambient Temperatures
▰ Temperatures are based on an ambient temperature of -20˚C to +40˚C
▰ The maximum surface temperature of an item of apparatus depends on
the temperature rise above 40˚C
75
The maximum permissible RISE in temperature is 45˚C
Ignition Temp Ambient Temp
Gas
Temp Class Temp Class
Methane 595˚C T1 40˚C T1
Ethylene 425˚C T2 45˚C T2
Diethyl Ether 170˚C T4 > 45˚C T5
76
EQUIPMENT PROTECTION LEVELS
▰ Where only zones are indentified in the area
classification documentation, then the
relationship between EPL's and zones shall
be followed.
▰ EPLs may be determined on the basis of
risk, i.e. taking into account the
consequences of an ignition.
77
EPL
Equipment Protection Suitable Zones
Level (EPL) of Use
Ga Zones 0, 1 and 2
Gb Zones 1 and 2
Gc Zone 2
78
EPL
If, the risk is considered especially severe, then the required EPL for the
zone may be increased
Normal Low
Zone High Risk
Risk Risk
1 Ga Gb Gc
2 Gb Gc Gc
The required EPL for the zone can also be decreased
79
CATEGORIES OF EQUIPMENT
Gas Group II is designated for explosive atmospheres relating to the oil and
gas industry, (Surface Industrial Applications)
80
Group it has been designed/tested for
Location
Flammable
Group Location Suitable for
Material
Use
Methane
I Below ground Group I
(Firedamp)
II Above ground Gases/Vapours Group II
III Above ground Dusts/Fibres Group III
81
The Categories of Group II equipment
Where the equipment is to be used:
Zone Zone Zone
The period of time over which the 0 1 2
potentially explosive atmosphere is
likely to be present:
82
The Categories of Group equipment
▰ Category 1G: Very high level of protection. Suitable for Zone 0
▰ Category 2G: High level of protection. Suitable for Zone 1
▰ Category 3G: Normal level of protection. Suitable for Zone 2
83
84
Test Yourself
85
Test Yourself
Which of the three zones has the highest risk of gas explosion?
Zone 0
86
Test Yourself
In relation to gas release, what is meant by the terms Continuous?
Continuous release relates to Zone 0 where the release
is expected to be continuous over a lengthy period of
time.
87
Test Yourself
In relation to gas release, what is meant by the terms Primary?
Primary release relates to Zone 1 where the release is
expected during normal operations occasionally.
88
Test Yourself
In relation to gas release, what is meant by the terms Secondary?
Secondary release relates to Zone 2 where the release is
not expected to occur in normal operations and, if it
does, then it will be of short duration only
89
Test Yourself
What does the term ‘explosive limits’ mean in relation to hazardous
atmospheres?
Upper and lower percentage concentrations of gas in
air above and below which explosion will not occur
90
Test Yourself
How should the T classification of an item of apparatus relate to the
ignition temperature of gas in which it is operated?
The maximum surface temperature at which
equipment will operate without igniting gas in the
atmosphere.
91
Test Yourself
How do the three categories of the hazardous equipment relate to their
level of hazard protection and gas zone?
Category 1: Equipment has a very high level of
protection.
Suitable for use in Zones 0, 1 and 2
92
Test Yourself
Category 2: Equipment has a high level of protection.
Suitable for use in Zones 1 & 2
Category 3: Equipment has a normal level of protection.
Suitable for use in Zone 2 only
93
Training Targets
• Identify hazardous area classified
Number 4 zones and gas groups
• Describe the factors relating to the
Number 5 ignition of explosive atmospheres
• Know the categories of equipment
Number 6 for use in explosive atmospheres
94
Activity
▰ For the fixed-roof storage tank shown,identify the hazardous areas zone
0, zone 1 and zone 2
95
Activity
96
Activity Define Zone 0
▰ Zone 0 is an area in which an explosive gas-air mixture is present
continuously.
97
Activity Define Zone 1
▰ Zone 1 is an area in which an explosive gas-air mixture is likely to
occur for short periods or occasionally in normal operation
98
Activity Define Zone 2
▰ Zone 2 is an area in which an explosive gas-air mixture is not likely to
occur, and if it does occur it will only exist for a very short time due to
an abnormal condition.
99