European Standard

160kW Integrated DC Charging Pile

Product Manual

Product Model: TEC-DC1.00/160


User Notification
Dear user,
Thank you for choosing the TELD products. You will learn more about our product
news and the latest technologies by following the TELD official WeChat account!

Use & Deployment Description


In order to put the equipment into use safely and efficiently, please read the instructions
carefully, and install and maintain your equipment according to the instructions.

Risk Notification
For your safe use of TELD's products, please carefully read the following risk notices:

This product is electric power related equipment. The installation, deployment,


operation and commissioning of the equipment should comply with relevant local
regulations and be completed by professional engineers and operation and
maintenance personnel. Do not install and put into use without permission. Please dial
TELD after-sales service hotline for professional services.

Please do not disassemble or modify the circuit yourself; otherwise the fault arising
therefrom will not fall within the TELD's warranty scope, and the company will not bear
any responsibility for personal injury arising therefrom.

After-sales Service
We hereby apologize that the TELD‘s product you purchased may not be completely
consistent with the manual due to the product’s upgrade.

TELD's best service will accompany you from the beginning to the end. Should you
have any question or come across any problem, please call our customer service
hotline (4001-300-001), and we are always at your service.
Contents
Product Introduction 1
Product Characteristics
Functions Configuration 2

Service Environmental Conditions


3
Product Parameters
Operating environment
4
Executive standard

Project Deployment Description 6


Installation Site Selection Conditions
Product Space Scale 7
Product fixation
Incoming line and wiring of product 8

Charging Operation Instructions 9


System power-on
Start charging 10

Charging completed
11
Export logs and upgrade versions
Emergency stop 20
Risk elimination and recovery
Description of equipment status indication 21

Maintenance Instructions
23
22
User Responsibility
Composition of Key Product Components
Classification and Replacement Cycle of Key Components 24
Regular patrol inspection requirements
Charging Pile Operating Specifications and Maintenance Instructions 25

Maintenance requirements for charger tip and charger holder


26
Troubleshooting of Common Faults
Maintenance Card
27
Installation Risk Notification 28
Operation & Maintenance Risk Notification
Use Risk Notification 29
Warranty Statement
Exceptions 30
Product Introduction

The European standard integrated DC charger is mainly composed of circuit breaker,


power module, power output unit, watt-hour meter, charging control unit (CCU) and
centralized control unit. It is a charging system for electric vehicles that can be directly
used outdoors, and can meet the charging requirements of all electric vehicles with
battery voltage within 50~1000V.

Spooling device

POS Machine
Indicators
Centralized control
screen
Emergency Stop

Charger holder

Product Drawing of European Standard 160kW Integrated DC Charging Pile

1
Product Characteristics
产品特点
Safe and reliable
• The whole unit and charging module meet TUV CE certification for safety
assurance;
• AC input Type A RCD residual current protection for safety assurance;
• The whole unit is dustproof, waterproof, moisture-proof, salt fog proof, mildew
proof and cold proof to withstand various climatic environments.
Friendly interaction
• Intelligent HMI and easy-to-operate; four-state display of the "standby, charger
inserted, charging, and fault" are clear at a glance;
• The optional charging cable management system is supported with charger line-
aided design to ensure the charger line will not fall to the ground, saving more
effort in operation and making the charger line more durable, and the station
cleaner.

功能配置

Strong adaptability
• 50-1000Vdc wide range output voltage, covering all car models and charging
scenes;
• TELD cloud platform and OCPP 1.6J protocol platform connection are supported;
• APP, card swiping, credit card, password entry, button entry and other startup
methods are supported to meet various application needs.
Efficient, smart and portable
• The peak efficiency can be more than 95%, which is highly efficient and energy-
saving; real-time detection of charger status, fault and alarm recording and
broadcasting, faster operation and maintenance;
• Integrated delivery of the complete unit and charging module with lower costs in
logistics and installation.

Service Environmental Conditions

Operating temperature - 30 ℃ ~ + 55 ℃
Storage temperature - 40 ℃ ~ + 70 ℃
Relative humidity 5% RH ~ 95% RH (no condensation)
Altitude ≤ 2000m (derating is required at 2000m~4000m)

2
Product Parameters
Product Model: TEC-DC1.0/160-CCDPM

T - EC DC 1.0
Company code Electrical vehicle Type of output Maximum output voltage
【 T 】 TELD 【 EC 】 【 DC 】 Direct Current 【 1.0 】 1000Vdc

160 - C C D P M
Company Connector 1 Connector 2 Electricity POS machine Charging cable
code type type meter type management system

【 160 】 160kW 【 C 】 CCS2 【 C 】 CCS2 【 A 】 DC meter 【 P 】 Configuration 【 M 】 Configuration


【 120 】 120kW 【 N 】 Not Configured 【 N 】 Not Configured 【 D 】 AC meter and 【 N 】 Not Configured 【 N 】 Not Configured
【 80 】 80kW DC meter
【 60 】 60kW

Parameter Name Description

Type of product TEC-DC1.0/160

Protection Grade IP54


Noise ≤65dB
DC output voltage range 50V DC ~ 1000V DC
Single-path output maximum
200A
current
Number of output circuits 2 loops
160kW
Output Power
≥95 %
Peak efficiency

Input system 3P+N+PE


Input Voltage Range 360V AC ~ 440V AC
Frequency 50/60Hz
Maximum Input Current ≤273A
Power factor ≥0.99
Dimensions 850mm (W) x 700mm (D) x 1860mm (H)
Weight ≤ 540kg (including charging module)

Optional devices POS machine, AC meter, charging cable management system

Networking mode Card swiping, POS, APP


Start charging method
Button, card swiping, password entry, plug-
Off Line Mode
and-charge

3
Operating environment
In order to ensure that the product reaches the design life, the following conditions should
be paid attention to during product deployment.

Solid foundation to avoid water Air humidity


accumulation The daily and monthly
The terminal shall be installed on average relative humidity shall
the solid ground or the environment be kept not more than 95%
with foundation is required, and the and 90% respectively
ground should be level and flat; No
strong vibration and impact are
allowed in the use environment

Altitude Low magnetic field


environment
The altitude shall not be more than
2,000m The induction intensity of
external magnetic field shall
not be more than 0.5mT

Executive standard
Standard No. Inspection Content

IEC 61851-1(2017) Electric Vehicle Conductive Charging System-Part 1: General Requirements


Electric vehicle requirements for conductive connection to an AC/DC power
IEC 61851-21
supply
IEC 61851-22 AC electric vehicle charging station

IEC 61851-23(2014) DC electric vehicle charging station


Plugs, socket-outlets, vehicle plugs and vehicle inlets - Conductive charging of
IEC 62196-1
electric vehicles - Part 1: General requirements
Dimensional compatibility and interchangeability requirements for a.c. pin and
IEC 62196-2 part 2
contact-tube accessories
Dimensional compatibility and interchangeability requirements for pin type and
IEC 62196-3 part 3 contact type vehicle couplers with rated operating voltage up to 1000 V d.c.
and rated current up to 400 A for special DC charging
ISO 15118-1-2013 General information and use-case definition

ISO 15118-2-2014 Network and application protocol requirements

ISO 15118-3-2015 Physical and data link requirements


Digital Communication between Electric Vehicle DC Charging Station and
DIN 70121
Electric Vehicle

4
Project Deployment
Description
Installation Site Selection Conditions
Collect and understand the location information of ground and underground tap water,
gas, heating and other pipelines within the red line of the construction site, determine
whether the safe distance for construction and operation meets the requirements, and
obtain relevant drawings of the original construction site, installation and electrical from
the site if conditions permit;

The site where the equipment is to be installed should be close to public facilities for
power supply, fire protection and flood prevention and drainage;

The site should be away from such hazards as potential fire and explosion;

It shall not be set in the place with dust, water mist or corrosive gas. When those
conditions cannot be avoided, the site shall not be in the downwind side of the
pollution source, or a place where there may be water accumulation and severe
vibration;

Whether there are public communication network signals in the area for the
convenience of contacting fire rescue forces;

The distance from high-voltage lines and towers should meet the requirements of local
laws and regulations, namely, all construction activities shall be outside the power line
protection zone;

The earthing system connected to the charging facility shall be a TN-S system, and the
ground resistance shall be less than 4Ω;

The sufficient electricity access load capacity shall be ensured at the place where the
charging equipment is used;

The terminal shall be installed on the solid ground or the environment with foundation
is required. The ground shall be ensured horizontal and flat;

The installation environment of charging facilities shall match the protection grade of
the shell of charging facilities to avoid water accumulation. The installation site shall be
free of explosive hazardous media, conductive media and harmful gases that can
damage insulation;

The site selection, installation and construction of charging facilities shall comply with
the local laws, regulations and related standards. The ventilation side and door
opening side shall not be installed close to the wall. Professional installation personnel
and qualified construction units shall be selected.
6
Product Space Scale

The following is an introduction to the door opening size and angle of the product.
When installing the equipment, the distance from the wall and obstacles shall not
affect the maximum opening range size of the product, so as to meet the maximum
opening angle for maintenance.

Top View of European Standard 160kW Integrated DC Charging Pile

Refer to the following table for the reserved space for product installation:

Description Recommended space

Distance from the front of the product to the boundary It shall be no less than 1000mm

Distance from the rear of the product to the boundary It shall be no less than 200mm

Distance from the left side of the product to the


It shall be no less than 800mm
boundary
Distance from the right side of the product to the
It shall be no less than 800mm
boundary

7
Product fixation

Top View: Look down from the top

As shown in the Figure,


the product engineering
installation dimension
diagram (top view),
lower right Φ 120mm is
the main incoming hole.

Front door

Incoming line and wiring of product


L1 line contact bank
L2 line contact bank
L3 line contact bank
N line contact bank

PE line bank

The figure below shows the three-phase AC incoming cable wiring copper bar.
The engineering cables L1, L2 、 L3, N and PE are respectively connected to the
corresponding positions shown in the figure.

AC cables are recommended for the following copper core cables:


160kW : YJV22-0.6/1kv-3×185mm²+2×95mm² 。

8
Charging Operation Instructions

APP charging
Charging startup modes

You can use mobile phone to


download APP and other
interconnection programs

Swiping-card charging

You can use the complimentary


charging card to start charging after
swiping the card at the card swiping
position of the device, and complete
the charging by swiping the card
again.

POS charging

You can choose POS machine to


POS swipe card to start charging, and
complete the charging by swiping
the card again.

9
System power-on

Power-on Preparation

Before power on, the manufacturer's representative of the charging system must be
informed. The trained electrical engineer must complete the system commissioning.
The rings, watches and other metal objects that may cause short circuits must be
removed.

During operation, pay attention to high-voltage hazards to avoid personal injury and
property loss. The system must be properly grounded before power on, and
installation inspection must be carried out before power on.

Confirm that the AC input front switch is disconnected and the charging gun tip is on
the cabinet body to ensure that all equipment is installed in place.

Please check the charging system one by one in accordance with the items listed
below.

Inspection
Inspection Content
Sequence

1 Ensure that the front switch of the system is not closed.

2 Close all molded case switches and micro-break switches in the cabinet
Multimeter shall be used for measuring if there is short circuit between AC inputs L1 L2
3
L3 N PE
Use a multimeter to measure that there is no short circuit between DC+\DC-\PE of two
4
charger tips respectively.
5 Hang the two charger tips at the designated position on both sides of the cabinet.

6 Open all molded case switches and micro-break switches in the cabinet

Power-on
1
Close the AC input front switch.
2
Use a multimeter to measure the voltage at the input side of the molded case
switch in the charging system cabinet. The input power supply voltage shall be
within the allowable working voltage range of the system.
3
Close the molded case switch in the charging system cabinet and close the
micro-break switch in the system. At this moment, the status indicator on the
front door panel of the system is on, the LCD is on.
4 The system automatically pulls in the AC input contactor and the charging
module starts.

10
Start charging
Charging Connection
1
First confirm that the charger is normal, that is, the corresponding status
indicator on the front door of the charger is green.
2
Confirm that the vehicle meets the charging conditions.
3
Remove the charger at the charger side and insert it into the corresponding
charging port of the vehicle. At this moment, the corresponding status indicator
on the front door of the charger is ice blue color.
4
Confirm that it is connected and proceed to the next step.

Interface Operation

Networking mode - start charging by swiping card


1
Click to swipe card
After inserting the charger, the
corresponding terminal interface on
the screen will display
"Connected", click "Swipe card to
start charging", and "Please swipe
card at the card reader" will be
displayed.

2
Swipe card
After swiping the card, you'll enter
the selection interface. The
charging modes include "Automatic
charging", "Set time charging", "Set
electricity quantity charging", "Set
SOC charging" and "Set amount
charging". Click the corresponding
interface and input the demand
value in accordance with the actual
needs.

11
3
Start charging
Input the corresponding demand value,
click the "Start now" button to prompt
the "Applying for charging" animation
interface, and return to the "Charging
result" prompt interface after response.

4
Charging
After the charging is started, the corresponding status indicator on the front
door of the charger will be in ice blue color. Click the corresponding terminal
interface to display charging information and battery information. Charger A
is taken as an example for charging status interface here.

5
stop charging
After the vehicle is charged as required, the charger will automatically stop
charging. The charging can also be ended by swiping the card in advance
on the main interface and the charging information or battery information
interface.

Networking mode - start charging with APP


1
Download mobile client
Search and download the APP in the app store, open the APP after registration,
scan the QR code of the corresponding charger in the charger interface.

12
2 Start charging
After scanning the QR code, click "Start charging with personal account", and
then click "OK".

3
Charging
After the charging is started, the corresponding status indicator on the front
door of the charger will be in ice blue color. Click the corresponding terminal
interface to display charging information and battery information. Charger A
is taken as an example for charging status interface here.

4
stop charging
After the vehicle is fully charged, the charger will automatically stop charging.
You can also stop charging by clicking the "Stop" button on the mobile client/
WeChat.

Networking mode - start charging with POS

1
Click POS card swiping
After inserting the charger, the
corresponding terminal interface on
the screen will display "Connected",
click POS card swiping to start
charging, and the screen will display
"Please swipe POS machine to start
charging".

13
2
Swipe card
After swiping the card, you'll enter the
selection interface. The charging
modes include "Automatic charging",
"Set time charging", "Set electricity
quantity charging", "Set SOC charging"
and "Set amount charging". Click the
corresponding interface and input the
demand value in accordance with the
actual needs.

3
Start charging
Input the corresponding demand value,
click the "Start now" button to prompt
the "Applying for charging" animation
interface, and return to the "Charging
result" prompt interface after response.

4
Charging
After the charging is started, the corresponding status indicator on the front
door of the charger will be in ice blue color. Click the corresponding terminal
interface to display charging information and battery information. Charger A
is taken as an example for charging status interface here.

14
5 stop charging
After the vehicle is charged as required, the charger will automatically stop
charging. The charging can also be ended by swiping the card in advance
on the main interface and the charging information or battery information
interface.

Local mode - local password entry to start charging


1
Click to input password
The "Connected" will be displayed on
the corresponding terminal interface
on the screen, click the password to
charge, and "Please enter the
password to start charging" will be
displayed.

2
Enter password
After clicking, you'll enter the
password input interface. Click the
corresponding interface, and input the
correct charging password.

3
Charging
After the charging is started, the corresponding status indicator on the front
door of the charger will be in ice blue color. Click the corresponding terminal
interface to display charging information and battery information. Charger A
is taken as an example for charging status interface here.

13
4
Stop charging
After the vehicle is fully charged, the charger will automatically stop charging.
You can also stop charging by clicking the "Stop charging" button on the
charging information interface or battery information interface and inputting
the charging password.

Local mode - start charging by swiping card

1
Click to swipe card
After inserting the charger, the
corresponding terminal interface on the
screen will display "Connected", click
"Swipe card to start charging", and
"Please swipe card at the card reader"
will be displayed.

2
Swipe card
After swiping the card, you'll enter the
selection interface. The charging
modes include "Automatic charging to
full", "Set time charging", "Set
electricity quantity charging", "Set SOC
charging". Click the corresponding
interface and input the demand value
in accordance with the actual needs.

3
Start charging
Input the corresponding demand value,
click the "Start now" button to prompt
the "Applying for charging" animation
interface, and return to the "Charging
result" prompt interface after response.

12
4
Charging
After the charging is started, the corresponding status indicator on the front
door of the charger will be in ice blue color. Click the corresponding terminal
interface to display charging information and battery information. Charger A
is taken as an example for charging status interface here.

5
stop charging
After the vehicle is charged as required, the charger will automatically stop
charging. The charging can also be ended by swiping the card in advance on
the main interface and the charging information or battery information
interface.

Local mode - plug-and-charge


1
Click plug-and-charge
The "Connected" will be displayed on
the corresponding terminal interface on
the screen, click the plug-and-charge,
and "Start charging" will be displayed.

16
2
Charging
After the charging is started, the corresponding status indicator on the front
door of the charger will be in ice blue color. Click the corresponding terminal
interface to display charging information and battery information. Charger A
is taken as an example for charging status interface here.

3
stop charging
After the vehicle is charged as required, the charger will automatically stop
charging. The charging can also be ended by swiping the card in advance on
the main interface and the charging information or battery information
interface.

Charging completed
1
Charging Terminal "Charging Completed"
Status charging
After is completed, the
"Charging report" will be displayed to view
the starting time, electric quantity
charged, charging duration, cause of stop
charging, current SOC information,
starting SOC information, charging
amount, and prompt "charging is
completed, please return the charger".
Click Continue Charging to scan the code
or swipe the card to continue charging.
2
Gun-Line Returning

After charging is finished, please insert the charging gun into the gun holder of
the charger to avoid damaging it.

17
Export logs and upgrade versions
Open the front cabinet door, insert the TELD encryption USB disk into the centralized
control USB port, and the pop-up window "Export log and upgrade version selection"
will show on the interface.
Export Log
1
Click the "Exporting log" button to pop up the "Log exporting" animation interface.

2
The log exporting results include "Hello, log exported" and "Log export failed,
please try again". Click the "Back" button or automatically return to the main
interface after the countdown.

Upgrading Version
1
Click the "Upgrading version" button to pop up the "Version upgrading, please
wait" animation interface.
2
After the system is upgraded, it will restart automatically. When the interface
prompts the calibration screen, the 5-point calibration screen operation must be
followed strictly according to the prompts to ensure that the touch function is
normal.
3
The version upgrading results include "Hello, upgrade completed; restarting" and
"Upgrade failed, please try again". Click the "Back" button or automatically return
to the main interface after the countdown.

Emergency stop

If you find any abnormality during charging, you


can press the emergency stop switch under the
condition of ensuring the safety of personnel.
After the emergency stop switch has been
pressed, the charging pile will immediately end
charging, stop output, and upload the information
to the HMI.

For the record: please do not touch the emergency stop switch in
case of non-emergency. If the equipment operation is abnormal due
to non-emergency situation, our company will investigate the legal
accountability.

18
Risk elimination and recovery

You can press and turn the emergency switch clockwise to


restore the normal state of the equipment.

Description of equipment status indication

Standby state
Solid Green

Charger insertion status


Ice blue light is constantly on

Charging
Ice blue light indicator

Fault State
The red light is constantly on

Note: When the red light is always on in case of fault, please contact the operation
and maintenance personnel directly.

16
Maintenance Instructions
User Responsibility
In daily operation process, user must carry out patrol inspection by himself every three
months. If any problem is found, stop using the equipment in time and contact the local
TELD operation and maintenance personnel for maintenance. See the regular patrol
inspection for specific requirements.

The product shall be maintained regularly every 6 months. The maintenance cycle must
be shortened under special environment (such as in high and cold area, or serious
pollution, etc.).

Keep relevant maintenance records properly, because in some cases you must show
these records to prove that necessary maintenance has been carried out;

The maintenance shall be carried out by professionals with reference to this manual. If
any parts are to be replaced, please strictly follow the electrical maintenance
requirements, and illegal operations are strictly prohibited.

Composition of Key Parts of the Product

DC power module

Incoming line
copper bar

Ground
wire

20
Air outlet system
components

Outgoing line
copper bar

Classification and Replacement Cycle of Key Components


Suggested
Classification Name of Part Included Remarks
Replacement Cycle

Structural Shell assembly, DC cabinet support, / Replace in time if it


components filter screen, and fan cover is damaged

Electrical Fan, DC power module, auxiliary / Replace in time if it


components source, and copper bar is damaged

Regular patrol inspection requirements


Inspection Important Inspection Inspection
Inspection Content Standard
Items Class Method Cycle

Check whether the air flow of the filter


screen at the air inlet is smooth. Spray the
filter screen body with an air gun to clean up
Air inlet Visual
the accumulated dust. Clean the catkins
filter inspectio 1 month
and other fabrics at the air inlet/outlet with a
screen n
brush. If the filter screen is seriously
blocked, replace the filter screen assembly
at the air inlet of the system

21
Inspection Important Inspection Inspection
Inspection Content Standard
Items Class Method Cycle

Check whether the cooling fan


System heat
operates normally and sounds Visual
dissipation 6 months
normally during the normal operation inspection
Fan
of the system.
Charging Check whether the charging system
system status indicator is normal under Visual
6 months
Status standby, plugged in, charging and fault inspection
Indicator conditions
Check the charging gun tip to see if
Visual
Charging gun there is any wear or leakage of copper 1 month
inspection
for the connecting cable of the tip

Charging Pile Operating Specifications and Maintenance Instructions


1
Confirm before charging: check, inspect and charge

Check whether the charger is damaged and whether the


interior of the charger is clean and free of foreign matters.

Before inserting the charger into the vehicle charging


socket, inspect whether the charging socket is clean and
free of foreign matters.

After confirming that the first two steps are normal, start to
plug the charger into the charging socket. During the
process of plugging, hold the handle of the charger with
one hand and hold the lower end of the charger with the
other hand to align the charger tip with the socket, and
insert the charger vertically into the charging socket with
even force.

• It is strictly forbidden to insert the charger and charger holder by rotating to a certain
angle.
• It is strictly forbidden to insert the charger into the charger holder at a certain angle.
• It is strictly forbidden to swing the charger from side to side during insertion, and it
must be inserted vertically with force.
22
2
After charging, pull out the charger by
holding the handle with one hand and
hold the lower end with the other hand
to pull the charger out vertically with
even force. It is strictly forbidden to
swing the charger from side to side
when pulling it out. It must be pulled out
vertically with force.

3
After the charger has been pulled out, the cable shall be straightened out without
obvious twisting, and then the charger shall be plugged back into an available
holder. It is strictly prohibited to discard the charger on the ground at will.

23
Maintenance requirements for charger tip and charger holder

The charger tip and charger holder must be cleaned every half month. If they are to be
used in the following three special environments, they must be cleaned regularly every
week.
1
High dust environment, such as construction site, sand and gravel yard, etc.
2
Inflammable and explosive environment, such as coal plant, mining area, and
distribution plant, etc.
3
High temperature environment, such as steel plant and smelting plant.

Troubleshooting of Common Faults


Failure Cause Analysis Troubleshooting

There is a problem with


The central control Check the AC input cable connection
the AC input cable
display screen does
not light up Q3 not closed Check if Q3 is closed

Q4 not closed Check if Q4 is closed


Fan fault Check the fan power supply terminal to confirm
Fan fails to work whether the power supply is normal; observe whether
the fan can rotate normally
Abnormal matching The system has no
Check if the module has been installed
of channel modules

Q3 not closed Check if Q3 is closed

Check if the power supply of the electricity meter is


Abnormal Electricity meter failure
normal;
communication of
electricity meter
485 communication
Check whether the 485 communication cable and
problem between
wiring between the ammeter and CCU are normal
electricity meter and CCU

Lightening arrester Check the small window of lightning arrester. If it turns


Lightning arrester problem
failure red, replace the lightning protection module in time

Charging module The charging module is


Replace the charging module
failure damaged

Emergency stop The emergency stop


Restore the emergency stop switch
fault button is pressed

The cabinet door is not


Close the cabinet door and the fault disappears
closed properly
Door magnetic fault
Wiring problem of door Check whether the door magnetic cable wiring is
magnetic switch normal

24
Maintenance Card
Maintenance date: Maintenance date:

Accumulated service time of the product: Accumulated service time of the product:

Maintenance personnel: Maintenance personnel:

Tel.: Tel.:

Maintenance date: Maintenance date:

Accumulated service time of the product: Accumulated service time of the product:

Maintenance personnel: Maintenance personnel:

Tel.: Tel.:

Maintenance date: Maintenance date:

Accumulated service time of the product: Accumulated service time of the product:

Maintenance personnel: Maintenance personnel:

Tel.: Tel.:

Maintenance date: Maintenance date:

Accumulated service time of the product: Accumulated service time of the product:

Maintenance personnel: Maintenance personnel:

Tel.: Tel.:

Maintenance date: Maintenance date:

Accumulated service time of the product: Accumulated service time of the product:

Maintenance personnel: Maintenance personnel:

Tel.: Tel.:

Maintenance date: Maintenance date:

Accumulated service time of the product: Accumulated service time of the product:

Maintenance personnel: Maintenance personnel:

Tel.: Tel.:

Maintenance date: Maintenance date:

Accumulated service time of the product: Accumulated service time of the product:

Maintenance personnel: Maintenance personnel:

Tel.: Tel.:

Note: The maintenance card shall be printed by the user.


25
Installation Risk Notification

The hoisting shall be subject to the instructions marked on the product. The hoisting
equipment and slings in line with requirements shall be selected for hoisting;

Such parts as cables and wiring terminals selected for installation shall meet the
current requirements. It is required to ensure the fastening of all wires, good
insulation, correct wiring, and no abrasion and squeezing risks related to the
charging equipment before and after installation. Otherwise, the risk of fire or electric
shock exists;

All holes into the charging equipment shall be properly sealed after wiring. Otherwise,
the prolonged burning risk of cables may occur. Before the equipment is powered on,
make sure to verify whether the equipment is properly grounded, and ensure the
grounding resistance is not greater than 4Ω, so as to avoid electric shock accidents;

Such devices as all protective housings and insulating bushes of electrical


components shall be ensured for no loss after installation. Otherwise, an electric
shock may occur;

If the components are damaged during installation, they shall be repaired or replaced
in time to avoid their use with defects;

It is required to confirm whether metal tools, combustibles or flammables are left in


the charging equipment after installation. Otherwise, a fire may occur.

The product shall be deployed away from the following abnormal environments: a
place near the pollution source; a place with corrosive and destructive material
environment around; environment with conductive dust, explosion hazard and heat
source; water accumulation environment, a place subject to collapse hazards; and an
area with impact of fire protection, power, gas and other functions.

Mold Conductive
Dust
medium

Corrosive Inflammable &


Heat source explosive substances
environment
Operation & Maintenance Risk Notification

It is not allowed to remove or transform the charging equipment and wiring without
permission. Otherwise, a fire or electric shock may occur;

Contact the staff or call the customer service hotline 4001-300-001 in case of power
failure;

Do not maintain the charging equipment without disconnecting the power supply,
which may cause electric shock.

Use Risk Notification

Please confirm whether the parameters of the electric vehicle match those of the
charging device before use, otherwise it may cause damages to the vehicle;

Product cannot be used in case of any equipment fault. If the charging is abnormal,
unauthorized operation is not allowed. For any abnormalities discovered, contact
the staff in time or call the customer service hotline 4001-300-001;

The operation procedures and prompts on the charging equipment shall be strictly
followed. Otherwise, an electric shock or fire may occur;

In case of fire, charging equipment soaking in water and other accidents, it is not
allowed to get close to the charging equipment. The staff familiar with equipment
and emergency processing methods shall be notified in time for emergency
processing;

The product shall be locked for management daily, and it is strictly prohibited to
open, connect, modify or damage the charging equipment without authorization,
otherwise an electric shock risk may occur;

The guardian shall pay attention to the children who move around the charging
equipment to avoid electric shock and other accidents.

26
Warranty Statement

Our company promises that the products are strictly checked for quality, and we will
repair the product for the quality problems in normal use within the warranty period.

Product damage or abnormal use caused by improper handling and installation,


incorrect use and maintenance, user's negligence or natural disasters shall not be
covered by the warranty.

Exceptions

In order to protect the lawful rights and interests of users, please carefully read the
product manual before using the charging equipment. Our company reserves the
right to update the above documents. The equipment shall be operated in strict
accordance with the operation procedures and safety notice.

Once you start to use the equipment, you are regarded that you have read,
understood, approved and accepted all terms and contents specified in the product
manual of the equipment. The user promises to bear the liability for own behaviors
and all consequences therefrom. The user promises to use the equipment only for
proper purposes, and agrees to this article and any other relevant policies or criteria
that our company may establish.

When using the equipment, you are requested to strictly follow and perform the
requirements, including but not limited to operation procedures, safety notice, product
installation conditions and product service conditions. The user shall self-bear the
relevant liabilities and losses for all personal injuries, accidents, property loss, legal
disputes and all other adverse events resulting in a conflict of interest caused by the
using behaviors violating the product manual or force majeure factors. Our company
will not bear any liability.

27
01

Qingdao TELD New Energy Technology Co., Ltd.

National unified service hotline: 4001-300-001


Address: No. 336, Songling Road, Laoshan District, Qingdao
Website: www.teld.cn