Automation and Drives
Project transfer to HMI devices
Addr. = 1
PROFIBUS
SITRAIN
WinCC flexible System course 1 / Project_transfer 08/2006
© Siemens AG, 2006 - All rights reserved
Automation and Drives
Learning targets
The participant will learn about
• Transfer requirements
• Transfer settings
The participant will be able
• to transfer a project
SITRAIN
WinCC flexible System course 1 / Project_transfer 08/2006
© Siemens AG, 2006 - All rights reserved
Automation and Drives
Transfer requirements
• Configured device type identical to type of target device
• Configured device version matches image version on target device
• Connection exists to target device (transfer interface settings)
Direct connection within a bus segment
Connection through routing
• Target device in transfer readiness (transfer mode active)
• Project can be generated without errors
File (*.FWX) is generated
Contains generated configuration data for the target device
• Transfer settings in WinCC flexible match the connection
SITRAIN
WinCC flexible System course 1 / Project_transfer 08/2006
© Siemens AG, 2006 - All rights reserved
Automation and Drives
Settings of the transfer interface
Select
protocol
Select physical
system
Enable
Interface
"OK" "Cancel" properties
SITRAIN
WinCC flexible System course 1 / Project_transfer 08/2006
© Siemens AG, 2006 - All rights reserved
Automation and Drives
Activate transfer mode on target device
Explicit transfer mode
started
Remote control
enabled
Transfer possible during
runtime
Runtime is automatically
terminated, and transfer
mode automatically started
Enable
SITRAIN
WinCC flexible System course 1 / Project_transfer 08/2006
© Siemens AG, 2006 - All rights reserved
Automation and Drives
Creating a project
or Toolbar Result of generation
WinCC flexible decides:
Only those configuration
changes that have been
made since the last
generation are compiled
Rebuild All -> the whole
project is compiled
SITRAIN
WinCC flexible System course 1 / Project_transfer 08/2006
© Siemens AG, 2006 - All rights reserved
Automation and Drives
Start project transfer
Device Transfer
Toolbar selection settings
or
...
Start
transfer
SITRAIN
WinCC flexible System course 1 / Project_transfer 08/2006
© Siemens AG, 2006 - All rights reserved
Automation and Drives
Transfer settings
Selection of HMI Transfer method Transfer options
device(s)
from the project - Transfer mode - Data storage
- Target device address - Transfer scope
For selected devices Start transfer
for all selected devices
SITRAIN
WinCC flexible System course 1 / Project_transfer 08/2006
© Siemens AG, 2006 - All rights reserved
Automation and Drives
Exercise: Transfer TP 177B configuration
• Set connection to target device
(settings of transfer interface on HMI device)
Connection over PROFIBUS DP
• Set target device to transfer readiness
(activate transfer mode "Remote control")
• Transfer a project
SITRAIN
WinCC flexible System course 1 / Project_transfer 08/2006
© Siemens AG, 2006 - All rights reserved