0% found this document useful (0 votes)
24 views8 pages

Partial Discharge Monitoring Tech

Hsens-T is a Transient Earth Voltage Sensor that can be used to detect external partial discharges inside metal clad switchgear or power cables termination box of rotating machines and power transformers. An application of HFCT along with TEV can help in PD diagnostic and confirmation of internal versus external PD.

Uploaded by

monitoringrugged
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
24 views8 pages

Partial Discharge Monitoring Tech

Hsens-T is a Transient Earth Voltage Sensor that can be used to detect external partial discharges inside metal clad switchgear or power cables termination box of rotating machines and power transformers. An application of HFCT along with TEV can help in PD diagnostic and confirmation of internal versus external PD.

Uploaded by

monitoringrugged
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 8

MONIT ORING SIMPLIFIED

HSENS-T
Rugged and Robust design to
measure partial discharges
HSENS-T Rugge d a nd Robust design to
measure partial discharges

Rugged and Robust design to measure


partial discharges in Power Transformers,
Switchgears, Rotating Machines and Cables
(and their accessories)

Hsens-T is a Transient Earth Voltage Sensor


that can be used to detect internal,
external and surface partial discharges
inside metal clad switchgear or power
cables termination box of rotating machines
and power transformers. An application of HFCT along with TEV can help in PD
diagnostic and confirmation of internal versus external PD. Sensor is IP65 rated with
integrated transient overvoltage protection feature inside sensor.
Transient protection will help in minimizing transients that can be expected during PD
monitoring. TEV sensor has strong magnets that help it to attach to the walls of metal
clad switchgear. TEV forms a capacitive coupling with grounded metal switchgear to
detect transients of external PD happening inside metal clad switchgear at termination.

Features
Transient Earth Voltage Sensor RG223 high noise immunity cable
Rugged and compact design with IP65 TNC connector for reliable
rating Strong magnets to attach connection
sensor
Transient overvoltage protection
integrated inside Sensor

Applications
Online periodic partial discharge
monitoring Offline PD measurement
during HV AC testing Multiple point PD
monitoring
Power
transformers
Rotating
machines
AIS/GIS
switchgear
0 Cables, joints
1 and terminations
HSENS-T
Benefits
Rugged and Robust sensors with IP 65 Customizable according to
rating Highly immune to noise customer specific applications

Rigorously tested Suitable for Online or


Offline PD measurements
Transient overvoltage
protection Heavy duty
magnets to hold sensors

Technical
Specifications
Type Integrated magnets help it to attach to metal clad
switchgear
SENSOR
Typical Respons (-6dB) 1 MHz - 100 MHz
Frequency e
Material Rugged Plastic (Black), other options available

Type RG223

SIGNAL CABLE Cable Gland (Sensor End) and TNC connector


Connectors
(Monitor End), other options available
Cable Length 5m as standard, other options available

IP RATING IP65

Ambient -30˚C – 70˚C


TEMPERATURE
Storage -40˚C - 85˚C

DIMENSIONS 70mm (L) x 70mm (W) x 33 mm (H)

CUSTOMIZATION For any different requirement, please consult


Ordering Code
Model of Sensor
(z = 0 to
9)
H s e n s - T z - y y - Sensor
Z Connector
TEV 0 = TNC
(Standard) 1 =
High Frequency Sensor Cable BNC
Partial Discharge Sensor Length
05 = 5 m (Standard)
10 = 10 m
15 = 15 m
20 = 20 m
DS0011R01_HSENS-

0
2
Asset Monitoring :
Enterprise
Architecture
Compatible with Rugge d Monitoring Enterprise
Solution

UI UX
- Data Layer
- Analytics
- User Interface
- Custom Dashboards
- Reporting
- Email/SMS Notifications

RM EYE

0
6

Private Cloud (Customer


Cloud), Rugged Monitoring
Cloud
IEC 60870-104 ODBC
IEC 61850 MODBUS
DNP 3.0
FTP/SFTP HTTPS
- XML, Data
MQTT
JSON Collection
- CSV,
COMTRA Asset Data
DE

Transform - Offline Test - Historian


Switchge Power Power
er Results - CMMS
ar Cable Electronics
Monitorin - Inspection - SCADA/
Monitorin Monitoring (Battery, UPS,
g System Records DCS
g System System VFD, Relay)
0 - Name Plate
3
One Solution for Multi-
Site Multi Asset
Monitoring
Manage different industrial assets on one
platform without human intervention

Features
Advanced and Exceptional Reporting Built on well-established remote
Technology with automated alerts and cloud-based monitoring
technology
Modern remote monitoring solutions
provide valuable insights to Multiple Simple user-friendly interface
Assets at Multiple Sites on real-time providing
fast access to all the features
Robust asset health monitoring and commands
with analysis and recommendations
support asset effectiveness in Quick and easy 1 step configuration
addition to maximizing equipment setup
uptime
Encompasses a secure access to
Establish a real time and consistent data and configuration
monitoring by getting the right
information into right hands Advanced asset algorithms based
on standard ones with new
An efficient, reliable partial ideas
discharge monitoring for all the
assets Systematic fleet management and
analysis
A detailed comprehensive DGA
Extended multilingual support to
Analysis Lifetime Consumption details. handle product inquires or
troubleshoot problems proactively
Features Specific to PD
Monitoring Up System Level
Realtime PD Alarm system
Reporting Industrial IoT
Partial Discharge monitoring and Get Alarm notifications for
Analysis PRPD : Phase resolve partial individual bushing parameters
over Email, sms and push
discharge
notificaions
Partial Discharge Amplitude and
Analytics on Online, and offline
Discharge rate trend analysis
partial discharge test data
Partial Discharge Fault localization
Artificial Intelligence based PD
fault Identification

0
4
Why Customers Choose
Us?
RM solution, the trusted monitoring solution for over 10000+ assets across 50+ countries.
We are a leading High Value Electrical Asset Monitoring Company integrating fibre optic
technology to the assets.

Attention to Details A plan for Success


It’s our attention to the small stuff, Our Customers are well satisfied
scheduling of timelines and keen with the advisory services that
project management that makes us we offer to help them with best
stand out from the rest. in class technological
performance and a long durable
life.

Experts only Meeting Deadlines Money Matters


We bring in our Work with us, and you’ll We protect
diversified experienced work with seasoned you against
team with over 100+ professionals – vigilant of currency
years of experience in deadlines, and committed fluctuation
Asset Monitoring to exceeding client with
expectations. competitive and
fair market
prices

0
5
Rugged Monitoring Services About Rugged Monitoring

Rugged Monitoring provides Industry’s leading team of asset


customization of sensors, monitors & condition monitoring experts with 100+
software. In addition we offer on-site years of combined experience
commissioning services, maintenance committed to delivering customizable
contracts and technical support to all solutions for challenging applications.
customers worldwide. We offer a range of reliable, high
performance, customizable sensors and
monitoring solutions that are immune to
external influence.

Certificatio
n

ISO ISO ISO 45001/ Llyod’ ATEX


9001 14001 OHSA S s Certifi cati
18000 Regist on
er

0
6
Our Presence Across the
Globe

Head Office
Canada
1415 Frank-Carrel,
Suite 230, Quebec,
QC - G1N
4N7, CANADA
+1-418-767-0111

Asia India Europe Latin Middle East North America


Pasific America

ruggedmon ©2021 Rugged Monitoring Company. All


rights reserved. Information subject to
[email protected]
change without notice. All trademarks
www.ruggedmonitoring.com are properties of their respective
companies, as noted herein.

MONIT ORING SIMPLIFIED