Bosch Video Management Systems

Your path to superior video recording management and performance

Bosch VMS 8.0 Bosch iSCSI Storage Products Overview


Bosch VMS Certification Training
Scope and purpose of this slide set
 This presentation is for presence based training purpose only.

 The slides are not self learning material, it is intended that a Bosch professional
trainer explains and gives additional information while going through the topics
step by step.

 The included hands on exercises and live demo scenarios require a test system
based on the specific Bosch Video Management System version as covered in the
training.

 All information and screenshots may be subject of change.

 The slides describe important topics from learning point of view but do not reflect all features and
functions of the Bosch Video Management System. The slides are not part of the product catalog
and do not replace the individual manuals (e.g. Configuration or Operation manuals) which can be
found on: www.boschsecurity.com
Security
select “Product Catalog”  select your country  “Products”  “Video”  “Video Software”  “Video Management Systems”
2 Systems | ST-ESS/MKK | November 2018
© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
Objectives

Get introduced to the Bosch iSCSI storage products in BVMS environment:

 RAID basics

 DIVAR IP Series

 NetApp E-Series

3 Security Systems | ST-ESS/MKK | November 2018


© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
RAID 5: Striping across multiple drives with interleaved
parity P
D1 D2 D3
P D1 D2 D3

D1 P D2 D3

D1 D2 P D3

 Protection against single disk failure


 Minimum 3 disks required
 Redundancy provided by parity
 Reconstruction:
– After disk failure RAID 5 restores missing data from parity or restores missing parity
from data

4 Security Systems | ST-ESS/MKK | November 2018


© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
RAID 6: Striping across multiple drives with dual
interleaved parity
D1 D2 D3 P1 P2
D1 D2 P1 P2 D3
D1 P1 P2 D2 D3
P1 P2 D1 D2 D3

 Protection against double disk-failure


 Minimum 4 disks required
 Redundancy provided by parity
 Reconstruction:
– After disk failure RAID 6 restores missing data from parity and/or restores missing
parity from data

5 Security Systems | ST-ESS/MKK | November 2018


© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
Hot Spare Disk (HS): What is the purpose of it?
Storage
System xyz
RAID
Group 1

HS

X RAID
Group X

• When a disk which is part of any RAID group fails, it can


be replaced by the next free HS-Disk available in the
system
6 Security Systems | ST-ESS/MKK | November 2018
© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
Supported iSCSI storage in Bosch VMS Environment
 The following iSCSI storage disk arrays have been tested:
 DIVAR IP Series:
 DIVAR IP 2000 => EOL in 2016
 DIVAR IP 3000
 DIVAR IP 5000 => New in 2016, replacing DIVAR IP 2000
 DIVAR IP 6000/7000 => EOL in 2016
 DIVAR IP 6000/7000 R2 => New in 2016
 NetApp DSA E-Series:
 DSA E2700 => EOL planned for end of 2017. Successor E2800
End of Life products:
 DVA-12T (EOL)
 DLA Series:
 1200 series (EOL)
 1400 series (EOL)
 DSA E2600 (EOL)
 NetApp FAS 2020, 2040, 3000-series (EOL)

7 Security Systems | ST-ESS/MKK | November 2018


© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
Bosch Storage Product Overview in BVMS environment

8 Security Systems | ST-ESS/MKK | November 2018


© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
DIVAR IP 5000 and 6000 Family Non BVMS
environment:
Live View + Replay
Feature set: via
• Video Security App
• Windows Storage Server 2012 platform or
• Video Client (BVC)
• Pre-licensed SW-components (dependent on DIVAR IP also Pre-
installed): Non BVMS Environment:
use
• Video Recoding Manager (VRM – Bosch Camera recording) Web-Configuration Wizard

and
• Video Streaming Gateway (VSG – for 3rd party camera
recording)
• Built-in transcoder (for remote low-bandwidth video streaming)

Used in two different environments:


• In BVMS environment just use as iSCSI Storage (optional: VRM)
• Standalone VRM based recording (no BVMS). Configured by the

9 Security Systems | ST-ESS/MKK | November 2018


© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

easy to use “Configuration Wizard” for quick installations


Bosch VMS – iSCSI Storage Overview
DIVAR IP 5000: Product Introduction
Hardware Changes (compared to precursor DIVAR IP
2000)
 Redundant NICs: default  teamed
 OS and Recovery on Solid State Drive (SSD)
 Paperclip Reset: camera like factory-default option
 Alarm I/O’s: 2 x Alarm Input, 2 x Alarm Outputs/Relays
 Tamper protection: Integrated 9-Axis-Sensor
 Door hinge more stable

Next generation dynamic transcoding:


 Ultra HD support: Support for all resolutions up to 4K.
 Multiple sessions: Up to four simultaneous sessions
10 in 4K resolution
Security Systems | ST-ESS/MKK | November 2018
© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
DIVAR IP 6000 Revision 2 Recording Appliance (2U or 3U)

Dedicated 2x SSD (RAID-1) with OS pre- Dedicated 2x SSD (RAID-1) with OS pre-
installed installed

2U rack mount unit variants: 3U hardware form factor, rack mount


• Without HDD for video recording but variants:
expandable up to 8x HDDs (up to 8TB • Without HDD for video recording but
HDDs) expandable up to 16x HDDs (up to 8 TB
• Fully populated with 8x up to 8TB hard HDDs)
drives (RAID-5; RAID-5 + HS, RAID-6)
• Also half populated with 4 HDD can be ordered • Fully populated with 16x up to 8 TB hard
For more details check out the datasheet on www.boschsecurity.com
drives (RAID-5; RAID-5 + HS, RAID-6)
11 Security Systems | ST-ESS/MKK | November 2018 Default: RAID-5
© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
DIVAR IP 6000 Revision 2 Recording Appliance (2U or 3U)

New features compared to previous DIVAR IP Series:


• Dynamic transcoding
UHD Resolution support: Support for any video device – also 4k cameras
Multiple sessions: up to four clients may receive transcoded streams at the same time
• Integrated SNMP and Web Monitoring Software of core components
 including SNMP Trap sending functionality related to: RAID Controller, HDDs, Power Supplies, Fans

For more details check out the datasheet on www.boschsecurity.com

12 Security Systems | ST-ESS/MKK | November 2018


© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
Complete BVMS System on board: DIVAR IP 3000 / 7000
DIVAR IP 3000
• 32 channels (cannot be expanded)
• 120 Mbit/s Operator
Client
• JBOD or RAID1*
• max 5 clients (5 pre licensed)
• OS: MS Storage Server 2008 R2
DIVAR IP 7000 Revision 2:
• 32 channels pre licensed  expandable up to 128 channels
• Available as 2U (max. 8 disks) or 3U (max. 16 disks) unit Optional: use
Configuration Wizard
• RAID-5; RAID-5 + HS, RAID-6
• up to 475 Mbit/s Bandwidth
• max 10 clients (5 pre licensed)
• OS: MS Storage Server 2012 R2

* Software based RAID1

For more details check out the datasheet on www.boschsecurity.com

13 Security Systems | ST-ESS/MKK | November 2018


© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
iSCSI Storage – hard limits per Hardware
 Each iSCSI storage array has its hard limitations (performance and capacity):
 Number of cameras which can parallel record to one iSCSI target
 Bandwidth (Mbps) => parallel writing to (camera recording) and reading from the iSCSI target (replay via
OP-Client)
 Net Storage capacity considering the RAID Level (Gross minus RAID Level storage consumption)
 Simultaneous iSCSI sessions per iSCSI Target:
 Each Camera can have maximum 2 iSCSI sessions when 2 iSCSI targets are assigned to it for recording:
 One session for the “mounted” Block which is used for the current recording (on iSCSI Target A)
 One session for the “pre-mounted” Block which is used for the next Block to record on (on iSCSI Target
B)
 Each VRM needs one iSCSI session to each iSCSI target for VRM based replay (default in BVMS Operator
Client)
 Each Workstation needs one iSCSI session to each iSCSI target when feature direct iSCSI replay is
enabled on a per
Writing workstation
to the iSCSI basis. Reading for
(recording) Replay

14 Security Systems | ST-ESS/MKK | November 2018


© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
iSCSI Storage – Hard Limits: What to consider for System
Design?

iSCSI session
RCP+

Storage
calculation
• Number of cameras per iSCSI Target?

via BVMS
Net storage capacity for Video Data?
• Total Bandwidth of one iSCSI Target related to Recording and Project
Replay? Checklist.xl
• Total Number of iSCSI Sessions per iSCSI Target can be handled? s
15 Security Systems | ST-ESS/MKK | November 2018
© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
iSCSI Storage – Hard Limits: DIVAR IP iSCSI Targets
*1 = MS Storage Server
Hard Limits 2008
# of cameras *2 = MS Storage Server
iSCSI Storage Models OS # of iSCSI Important note for
Bandwidth (Mbps) parallel 2012
sessions
recording
Bandwidth:
DIVAR IP 2000 -> EOL in 2016 *1 100 128 32 For all DIVAR IP
products which have
DIVAR IP 3000 *1 120 128 32 given a range in
32 (non BVMS) bandwidth column:
no RAID = 130-310 Check out always the
DIVAR IP 5000 -> New in 2016 *2 128 127** (part of
RAID1 = 90-200
BVMS) Data Sheet to find out
the detailed value
DIVAR IP 6000 -> EOL in 2016 *1 200 128 128
which is dependent on
DIVAR IP 7000 -> EOL in 2016 *1 200 128 128 the RAID-Level used.

# of iSCSI sessions: 128 (non BVMS)


RAID5 = 550
DIVAR IP 6000 R2 -> New in 2016 *2 256 This value is not 255** (part of
RAID6 = 475
mentioned in the data BVMS)
RAID5 = 475 sheet of the product
DIVAR IP 7000 R2 -> New in 2016 *2
So the limiting factor can be the Bandwidth 256 128
RAID6(read
= 475 and write) or the camera count but important for load
** one session is reserved for VRM replay non BVMS means: VRM stand alone environment balancing in VRM.
16 Security Systems | ST-ESS/MKK | November 2018
© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
iSCSI Storage – Load Balancing on VRM Pool Level
Where to configure the Bandwidth and iSCSI sessions?
When more than one iSCSI Target is configured to a Pool operating in “Automatic mode”:
 Important to correctly define the hard limits of each iSCSI storage array
 The Bandwidth value is the key factor for the load balancing algorithm between iSCSI storages
within the storage pool.
 The Bandwidth needs to be given on each iSCSI Target in BVMS by the Config-Client (check the
values in the Datasheet of the iSCSI Storage device)
 Device Tree-> click on the iSCSI device-> Right click “Load Balancing”
Note:
 Only one iSCSI Target is configured within a VRM pool:
No Load Balancing possible (this applies e.g. when
only one DIVAR IP 7000 is deployed)
 In BVMS 7.x there is only one iSCSI device type for DIVAR
IP 6000R2/7000R2 even different bandwidth is required:
Adapt the values manually as given in the datasheet (or
17 Security Systems | ST-ESS/MKK | November 2018 slide before).
© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
DSA E2700 Series with Bosch Firmware: Benefits
 DSA E-Series is an co-branded product from NetApp with Bosch specific operating
mode  can be purchased only from BOSCH
 High storage efficiency with
expansion shelves 1–4
5–8
9–12

High-density shelf with small footprint & power savings


 RAID Protection
Standard RAID-5 / RAID-6  conformant with most tenders
 Initialize / Factory Reset
Time for reconfiguration less than 1 hour
 High out-of-the-box scalability with respect to
capacity, bandwidth and
higher number of iSCSI Sessions (see firmware/ setup dependencies)
up to 1050 Mbps recording bandwidth per controller
 Price per net GB in a competitive range.

18 Security Systems | ST-ESS/MKK | November 2018


© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
DSA E-Series E2700 Product Overview
 Base Controllers  Expansion Shelves
 2U 12-bay with  2U 12-bay with
 2TB, 3TB, 4TB or 6TB hard drives  2TB, 3TB, 4TB or 6TB hard drives
 RAID-5 or RAID-6 protection  RAID-5 or RAID-6 protection
 Simplex Controller or  4U 60-bay with
 Dual simplex controller support  3TB, 4TB or 6TB hard drives
(to address the price and reliability needs)  RAID-5 or RAID-6 protection
 2x 10GbE iSCSI connectivity  Requires dual simplex base controller
Simplex Controller rear view  Max. 7x 2U or 3x 4U expansion shelves per
controller
Ch 1 Ch 2 Port 1 Port 2
Lnk Lnk Lnk Lnk

Lnk Lnk

Lnk Lnk
iSCSI Host
S LS L
Port 1 Port 2 ID/ Drive Expansion
Diag
Ch 3

Ch 4
V 100-240 50/60 Hz

V 100-240 50/60 Hz
A 9.0 - 3.6

A 9.0 - 3.6

DC AC DC AC
額定電壓頻率

額定電壓頻率
額定電流

額定電流

Dual Simplex Controller rear Controller or Expansion shelf front


view Lnk

Lnk
Ch 1 Ch 2
Lnk

Lnk
iSCSI Host
Lnk

Lnk
Port 1 Port 2 Lnk

Lnk Lnk
Ch 1 Ch 2
Lnk Lnk

Lnk
Port 1 Port 2 Lnk

Lnk
view
S LS L Lnk Lnk
Port 1 Port 2 ID/ Drive Expansion
Diag
Ch 3

Ch 4

Port 1 Port 2 ID/ Drive Expansion


Diag

1–4
V 100-240 50/60 Hz

V 100-240 50/60 Hz

5–8
9–12
A 9.0 - 3.6

A 9.0 - 3.6

DC AC DC AC
額定電壓頻率

額定電壓頻率
額定電流

額定電流

Scalable solution which quickly and easily expands to hundreds of TB with a small storage fo
19 Security Systems | ST-ESS/MKK | November 2018
© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
DSA E-Series (E2700): Recommended Hard Limit Values
iSCSI Ports Hard limits
Data bandwidth (Mbps)
iSCSI (per controller for DSA E- Why is the
Storage RAID iSCSI Series) bandwidth
Models Speed Port Usage higher when
sessions Base unit +
Base unit only min 1 adding
(writing/reading) expansion unit expansions
(writing/reading)
shelves on top
Single Port of a Base unit
400 650 / 150 1050 / 200
RAID (CH3 Only) controller?
DSA 1 / 10
5/ Dual Port
E-2700 GbpE
 Performance
RAID 6
data per controller
(CH3 &unit is800 (400
based in a 10
650Gbps
/ 150 network.
1050 / 200
per port)
CH4) network bandwidth is the limiting factor.
 In a 1 Gbps network, the available
 Bandwidth data refer to <Recording> / <Replay>.
 Overall bandwidth specification is per controller and does not depend on the number of used
ports.
 The number of cameras will double by using two ports instead of one.
20  iSCSI sessions refer to total number of recording and replay sessions.
Security Systems | ST-ESS/MKK | November 2018
© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
DSA E-Series E2700 controller series
 Scalability

• Single (Simplex) E2700 Controller

• Max. 7x DE1600 expansion shelves per system (single controller unit)

• DE6600 shelves are not supported

• Dual (Simplex) Controller

• Max. 7x DE1600 expansion shelves per system (dual controller unit)


Only for DE1600 shelves bought after the release of E2700

• Max. 3x DE6600 expansion shelves per system (dual controller unit)

Note: EOL E2600 dual simplex controller was not released with extension shelf of Type

21
DE1600.
Security Systems | ST-ESS/MKK | November 2018
© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
DSA E-Series Integration
 Support of DSA E-series iSCSI storage array with dual controllers.
 E-Series must be preconfigured with Configuration Manager:
Assign IP addresses for Management and iSCSI Ports, Adjust Network Port Speed
 After that targets can be added to BVMS by Configuration Client.

22 Security Systems | ST-ESS/MKK | November 2018


© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
DSA E-Series Integration
 In BVMS Configuration Client add E-Series manually

23 Security Systems | ST-ESS/MKK | November 2018


© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
DSA E-Series Integration
 Enter Management address.
 Enter password.
1
2  Click Connect.
 Other settings are retrieved automatically.
 In case of single controller unit only
Controller group will be populated. 2nd
Controller group will be left grayed out.
 4 targets are added to the pool.
 Targets can be moved to other pools.
3

24 Security Systems | ST-ESS/MKK | November 2018


© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
Bosch iSCSI Storage Solutions in BVMS Environment:
Summary
 Hard Limits for iSCSI Storage in BVMS which can be configured on Storage Device level:
Maximum number of iSCSI sessions.
Maximum bandwidth for writing/reading to/from a system.
DIVAR IP 6000:
 Is a perfect choice for up to 64 TB storage demand and 550 Mbit/s bandwidth for one system.
 Multiple DIVARs are possible to increase the storage demand and deploy iSCSI redundancy
(up to 4 x DIVAR IP 6000 2U and up to 3 x DIVAR IP 3U within one VRM pool).
 RAID 5/6 and Hot spare disk support.
DSA E2700 series:
 Is a high scalable Enterprise graded storage solution up to 1152 TB in one system and up to 1050
Mbit/s bandwidth.
 RAID 5/6 and Hot spare disk support.
 Special Bosch Firmware on top of the controllers ensures high performance and reliability for
recording of video data within a Bosch Camera and VRM Environment.

25 Security Systems | ST-ESS/MKK | November 2018


© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
Short outlook to the E2700 successor: DSA E2800
Controller Unit Expansion Unit
E2812
4.0TB 4.0TB 4.0TB 4.0TB

DE212C

12 bay
4.0TB 4.0TB 4.0TB 4.0TB

4.0TB 4.0TB 4.0TB 4.0TB

- E2800 Product is now launched and


released with BVMS 8.0

2 5 8 11

1 4 7 10

0 1 2 3 4 5 0 3 6 9 6 7 8 9 10 11
Front

2 5 8 11

1 4 7 10

0 3 6 9

60 bay
0 1 2 3 4 5 6 7 8 9 10 11
Front

2 5 8 11

1 4 7 10

0 1 2 3 4 5 0 3 6 9 6 7 8 9 10 11
Front

2 5 8 11

1 4 7 10

0 1 2 3 4 5 0 3 6 9 6 7 8 9 10 11
Front

2 5 8 11

1 4 7 10

0 1 2 3 4 5 0 3 6 9 6 7 8 9 10 11
Front

26 Security Systems | ST-VS/MKP4.1 | November 2018


© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
Short outlook to the E2700 successor: DSA E2800
LNK LNK P1 P2
0a 0b

 Two additional optical ports on the Base Host


LNK LNK

e0c e0d

EXP1 EXP2

 Bandwidth: 1250 Mbit/s (Single or Dual controller system with min 24 HDDs)

 Number of iSCSI sessions: 400 per port -> max 800 per Single or Dual controller system nd
a
d
 Higher capacity drives
che
un .0
– 4TB, 8TB and 10TB (new) options are available at product launch la S 8
o w M
 Improved configuration and monitoring n BV
s
i th
t
c wi
u
od sed
– Web based GUI for expert settings that cannot be configured via Bosch tools
r
P a
– SNMP Traps can be received directly from the storage system 00
e le
28 r
-> no need to install SANtricity Storage Manager -E

27 Security Systems | ST-VS/MKP4.1 | November 2018


© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Questions?
Bosch VMS – iSCSI Storage Overview
RAID 0: Striping
Disk 1 Disk 2 Additional
B O Information for
S C self study (not
H relevant for the
exam)

Data Word = BOSCH


• No protection against failures
• Mainly used to increase the performance
• Load is distributed to multiple disks
• Single failure affects the entire stripe set
29 Security Systems | ST-ESS/MKK | November 2018
© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
RAID 1: Mirroring
Disk 1 Disk 2 Additional
B B Information for
O O self study (not
S S relevant for the
C C exam)
H H

Data Word = BOSCH

• Protection against single disk failures


• High overhead

30 Security Systems | ST-ESS/MKK | November 2018


© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch VMS – iSCSI Storage Overview
JBOD: Just a Bunch Of Disks
Disk 1 Disk 2 Additional
B C Information for
O C self study (not
S T relevant for the
C V exam)
H Disk 1: Data Word = BOSCH
Disk 2: Data Word = CCTV

• No protection against failures


• Disks either appear individually or are combined to larger
volumes
• If disks are exposed individually – disk failure does not
affect other disks in the JBOD
31 Security Systems | ST-ESS/MKK | November 2018
© Robert Bosch GmbH 2016. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.