Wave
Mall,
Noida
Sector -
18 study
  Mall Case
              Group 5: Tanzeeha khan, Rifa Maroof, Sameena Tanweer, Mohd. Javed, Faique
              Ahmed
INTRODUCTION
Location: Noida, Sector 18
Opening year: 2003
Owner: Wave Group
Architect: Hafeez contractor
Type: Shopping mall cum entertainment
complex
Total site area: 8777.75 SQM
Total floor area: 32,516 SQM
Total retail floor area: 23,783 SQM
                                        2
No. of floors: 8
LOCATION
Address: Pocket J, Sector
18, Noida, Uttar Pradesh
201301
Accessibilit
y Nearest Metro: Noida sector
   18
                   (430m)
   Nearest Bus stand: 300m
   Nearest Airport: Indira Gandhi
   international Airport
    Highway
    Roads                           3
4
LOWER
GROUND
FLOOR PLAN
CIRCULATION:
-Follows linear hierarchy
-2 capsule lifts, 2 escalators, 5
staircases
-3m wide corridors
-3m wide staircases(2)
-2.5m wide staircases(2)
-1.5m wide staircase
-640 sqm. space for atrium
GROUND
FLOOR PLAN
CIRCULATION:
-Follows linear hierarchy
-2 capsule lifts, 2 escalators,
5 staircases
-3m wide corridors
-3m wide staircases(2)
-2.5m wide staircases(2)
-1.5m wide staircase
-512 sqm. space for atrium
FIRST
FLOOR PLAN
CIRCULATION:
-Follows linear hierarchy
-2 capsule lifts, 2 escalators,
5 staircases
-3m wide corridors
-3m wide staircases(2)
-2.5m wide staircases(2)
-1.5m wide staircase
SECOND
FLOOR PLAN
CIRCULATION:
-Follows linear hierarchy
-2 capsule lifts, 2 escalators,
5 staircases
-3m wide corridors
-3m wide staircases(2)
-2.5m wide staircases(2)
-1.5m wide staircase
THIRD
FLOOR
FLOOR PLAN
CIRCULATION:
-Follows linear hierarchy
-2 capsule lifts, 2 escalators,
5 staircases
-3m wide corridors
-3m wide staircases(2)
-2.5m wide staircases(2)
-1.5m wide staircase
FOURTH
FLOOR
FLOOR PLAN
CIRCULATION:
-Follows linear hierarchy
-2 capsule lifts, 2 escalators,
5 staircases
-3m wide corridors
-3m wide staircases(2)
-2.5m wide staircases(2)
-1.5m wide staircase
FIFTH
FLOOR
FLOOR PLAN
CIRCULATION:
-Follows linear hierarchy
-2 capsule lifts, 2 escalators,
5 staircases
-3m wide corridors
-3m wide staircases(2)
-2.5m wide staircases(2)
-1.5m wide staircase
SIXTH
FLOOR
FLOOR PLAN
CIRCULATION:
-Follows linear hierarchy
-2 capsule lifts, 2 escalators,
5 staircases
-3m wide corridors
-3m wide staircases(2)
-2.5m wide staircases(2)
-1.5m wide staircase
Multiplex
  • Multiplex are located at third and sixth floor.
  • They can be reached through escalators, lifts and
    staircases.
  • All multiplexes are connected with a common corridor.
  • A common lobby has been provided for both the
Inferences:
    multiplexes.
  • Adequate number of toilets are not provided.
  • No toilets for provided for differently abled people.
  • Entrances and exits have been adjusted according to
    the level.
  • This has been done to adjust the flow of traffic during
    peak hours
                                                              13
Services
           14
Parking
• Parking is provided on lower
  ground floor and basement at
  -2 level.
• Total area for parking is
  4700sqm.
• Parking area is 23% of the
  built up area.
• Total number of car parking is
  110 on both the levels.
                                   15
Area
Statement
            16
Area statement
Inference
s
Positives
• Main floor; makes or breaks the motive of visitor(first impression is the
  last impression).
• Characterized by huge open area; acting as a buffer between exterior
  and interior. Alleviates sudden transition which often is disorienting.
• Consists of ancillary spaces that are the prime motive of this program.
• Break in the flow of spaces. Consists of spaces of different typologies
  This is to ensure a break in the monotony of the shopping experience of
 Negative
  the shopper.
•sSubstantial amount of parking should be provided in order to accommodate
    the crowd i.e. 60% of the built up area according to the UP bylaws.
•   Washrooms are not provided on every floor.
•   segregation of service areas and public areas should be done properly.
•   Entertainment zones like arcade is missing on the upper floors from the mall.
•   Common area should be provided in adequate amount so that any visitor
    can have visual access to the mall; and can have a blueprint idea of the
    space, making it easier for them to move around.
Material and
Exterior
• The building exterior surface has been efficiently
  utilized for branding and advertisements wherein
  not affecting the aesthetics of the elevational
  feature of the building.
• Contemporary outlook has been maintained with
  the use of materials currently trending like
  aluminium composite panels and glazed facades.
• The entrance lobby and atrium has been
   covered with fiber glass which allows
   light to penetrate but covers up the area
   efficiently and reduces the use of
   artificial lighting,
                                                       19
Thank You.
             20