Megapower 3-Level YDC3350E YDC33200E - 052021

The Megapower 3-Level YDC3300 E Series is an online UPS system designed for mission-critical and industrial applications, offering high reliability, low cost of ownership, and efficient service concepts. It features a true online double conversion topology, advanced charging modes, and modular design for easy maintenance, with efficiencies up to 95.5% and a rated output power factor of 1.0. The system supports various configurations and has extensive remote monitoring options, making it suitable for diverse environments including telecom, banking, and healthcare facilities.

Uploaded by

Stuart MacPhail
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
173 views76 pages

Megapower 3-Level YDC3350E YDC33200E - 052021

The Megapower 3-Level YDC3300 E Series is an online UPS system designed for mission-critical and industrial applications, offering high reliability, low cost of ownership, and efficient service concepts. It features a true online double conversion topology, advanced charging modes, and modular design for easy maintenance, with efficiencies up to 95.5% and a rated output power factor of 1.0. The system supports various configurations and has extensive remote monitoring options, making it suitable for diverse environments including telecom, banking, and healthcare facilities.

Uploaded by

Stuart MacPhail
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 76

Megapower 3-Level

YDC3300 E Series

Product
ProductPresentation
Presentation
05/2021
Megapower 3-level
YDC 3300 E series
Online UPS System

Pantone Black C; RAL9005


50/60/80/100/120/160/200kVA/kW
3P 4W System

50kW/60kW 80kW/100kW/160kW 200kW


Mission critical & industrial applications
 Operator Centres, Servers, Computer rooms,
 Telecom Switchgear & Infrastructures,
 Processing Control Equipment,
 Security Systems, Emergency Lighting, Fire
Protection,
 Airport Infrastructure,
 Bank, Hospital, Healthcare Equipment …
Main Features
High Reliability
Low Cost of Ownership

Efficient Service Concept


Space-saving and Simple to Service
Mains-friendly with Low Input Harmonics and Advanced PFC

Technical Specifications
High Reliability
 True Online Double Conversion with 3-level Inverter
Topology
 Energy Control Module for Parallel Control
 Redundancy Auxiliary Power Supply and Fans
 Conformal Coating on PCB Enables to work in harsh
environment
 N+X Parallel Redundancy
 Extended Backup Time Availability
High Reliability
 Powerful Power Module May provide >30% Charging
Capacity
 3-level Intelligent Charging Modes
True Online Double Conversion
Single Line Diagram

Bypass

I/P AC/DC
O/P
EMI BUS DC/AC EMI
Converter Inverter

DC/DC Charger
Converter

Battery
3-level Inverter Topology
Energy Control Module
 For Parallel Control
Redundancy Auxiliary Power Supply and Fans
 Avoid Single Point of Failure
 Support 50% load if one fan is in failure; support 30% load
if two fans are in failure

Redundancy
Conformal Coating on PCB Enables to work in
harsh environment
 Can Work under dust, salty & Misty Environment
 No derating at 40 C
N+X Parallel Redundancy
 Up to 6 UPS can be in Parallel
 More than 1 UPS can be in redundancy
Extended Backup Time Availability
 Powerful Charger 20A for 50kW/60kW, 40A for
80kW/100kW/120kW & 60A for 150kW/200kW
 Matching Battery Cabinet for long backup
Powerful Power Module May provide
>30% Charging Capacity
 Max. 20A per 50kW/60kW and 40A for
80kW/100kW/120kW and 60A for 150kW/200kW
 No need for additional external charger

40A

20A
3-level Intelligent Charging Modes

Equalized Floating
Boost 0.1C =>10H
0.05C=>20H 0~6H

(Boost Charge 2.30V to 2.35V per cell &Float Charge 2.20V to 2.29V per cell)
Low Cost of Ownership
 Up to 95.5% system efficiency
 Up to >=99% efficiency in Eco-mode
 Rated Output Power Factor 1.0
 Near-unity Power factor at partial and full loads
 Wide Input Voltage/Frequency Range
 Superior Overload Capability
 Back feed Protection
 De-rating Operation Available
 Adjustable Battery Voltage(30 ~50 blocks)
 Common Battery
 Dual Input Feed
 Modular Design Concept for 100K Above
 Frequency Converter Mode Is Selectable
Up to 95.5% system efficiency
 Efficiency 94.9% from 10% load
 Flat Efficiency Curve for a Wide Range of Load
Efficiency η
98

96

94
230V
92 220V
Efficiencyη ( % )

90

88
% Load 230V
86 10% 94.40
20% 95.30
84
30% 95.48
82 40% 95.34
230V 50% 95.51
80 Efficiency (10 60% 95.48
% Load 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
points) 70% 95.37
LOAD(%) 80% 95.23
90% 95.13
Up to >=99% efficiency in Eco-mode
 Suitable for good grid area
 Transfer time back to online mode: <5ms
High Efficiency of Up to 95.5% at Low Load
High and Constant Efficiency

√ Traditional UPS operates at efficiency below 85% when in parallel configuration


(10% to 50% system load rate)
√ KSTAR UPS achieves 95.3%efficiency at 75% load rate
√ KSTAR UPS achieves 95.5% at 50% load rate
√ KSTAR UPS achieves 95.46% efficiency at 25% above load rate

Efficiencyη ( % )
KSTAR UPS
98.0
95.46 95.50 95.30
96.0 94.75
94.0 5.5% difference
12.5% difference
92.0 Traditional UPS
90.0
88.0
86.0
84.0
82.0
80.0
25% 50% 75% 100%
LOAD(%)
High Efficiency >95.5% at Low Load Rate
Typical load of 200kW , Air-Con COP=3, electric charge=0.16USD/kWh
Legacy UPS Present UPS in the industry KSTAR UPS
UPS Efficiency 85% 90% 92% 94% 95.5%
UPS power dissipation per 309, 176 194, 667 152, 348 111, 830 81158
year(kWh)
Cooling power dissipation 103, 059 64, 889 50, 783 37, 277 27053
per year(kWh)
Total power consumption 412, 235 259, 556 203, 130 149, 106 108,211
per year(KWh)
Total power cost per 66, 336 41, 767 32, 687 23, 994 17413
year(USD)
Power cost over KSTAR UPS 48,923 24,354 15,274 6,581 0
(USD)

Yearly Power Cost/USD


70000
60000
50000 Power consumption
40000 reduced by 76.6%
30000
20000
10000
0
85% 90% 92% 94% 96%
Rated Output Power Factor 1.0
 Supply loads from 0.5 leading to 0.5 lagging without de-rating
 Can connect 25% more than traditional UPS
Wide Input Voltage/Frequency Range
 Voltage Window: 138V~485V
 Frequency Window: 40~70Hz
 6KV/5KA Lightning Protection

40℃ 323~485V: 100% Load


323~138V: de-rating load
30℃ 305~485V: 100% Load
305~138V: de-rating load
Superior Overload Capability
 Inverter: 110% for 60 min., 125% for 10min., 150%
for 1 min., >=1000% for 100ms
 Bypass: 135% continuously; >=1000% for 100ms
Back feed Protection
 Monitor Bypass SCR status;
 Drive the bypass breaker.

UPS Instruction
Pin1 IN or OUT
Pin3 IN or OUT

No bypass contactor built-in


De-rating Operation Available
 Temperature: Normal operation at
0~40 C & 12% per 5 C (max. 50 C)

 Altitude:

Altitude
(m) 1500 2000 2500 3000 3500 4000 4500 5000

Load
100% 95% 90% 85% 80% 75% 70% 65%
coefficient
Adjustable Battery Voltage(30 ~50blocks)
 Flexible Battery voltage, No need to over-size the
batteries
 No Interruption might occur when few blocks of the
batteries connected to the same string are broken

• 30 blocks: 0.8PF
• 32-34 blocks: 0.9PF
• 36-50 blocks: 1.0PF
Common Battery
 Flexible battery configuration 30~50 blocks
 All UPS in Parallel Share One Battery String
 Big Saving for Battery Management Investment
 Maximize cost Effectiveness
 Minimize Floor Space

Battery Cabinet
Battery Voltage v.s. Output Power Factor

30 Blocks 32-34 Blocks 36~50 Blocks


Power Factor 0.8 PF 0.9 PF 1.0 PF
Dual Input Feed
Modular Design Concept for 100K Above
 If one of the modules is out of order at <50% load for
100K/120K and 67% load for 150K/180K, the UPS may
work continuously without interruption
 Modular design concept saves maintenance cost
For 7” LCD Display Upgrade
 RJ485(RJ45)Port on the rear panel
 LCD Firmware Upgrade via UPSService software
Efficient Service Concept

 Easy Swappable Module with Condition


 Fan Replacement from Front
 Filter Swap from Front
 User-friendly LCD
 Superior MTBF & MTTR
 Remote Monitoring and Connectivity Options
Filter Swap from Front
User-friendly LCD
 Thin film transistor(TFT) LCD
 Supports Multi-languages
 Real-time Meter Readings of System Currents, Voltages,
Active and Reactive Power
 Status Reports and History Files
 System Power Flow On-line Diagram
Event log Shown On the Display
 1000~10,000 Event Can be Recorded
 Event Log can be exported
 First-in First-out Principle
User-friendly LCD
Remaining Backup Time on LCD
User-friendly LCD
 Basic Setting
 Advanced Setting

Password:111111
User-friendly LCD
Basic Setting
 Language
 Password
 Brightness
 Time & Period
 Communication Setup

Password:111111
User-friendly LCD
Advanced Setting
 System
 Parallel
 Output
 Battery
 Bypass
 Dry Contact

Password:191210
User-friendly LCD
System Setup
User-friendly LCD
 Frequency Converter Mode
 LBS mode
 Float Temperature Compensation
 Temperature Sensor Select: NTC and RS485.
p.s. NTC for single and short distance. Rs485 for multiple and far distance.
User-friendly LCD
 Inter Power Walk in: Rack to Rack
 Inter sleep mode
User-friendly LCD
Parallel ID
Parallel Cabinet Quantity
Redundancy Cabinet Quantity
User-friendly LCD
Battery Group(String)
Battery number: The value can be 30~50, default value is 30.
Single Battery Capability 7AH~2000AH.
Boost/Float conversion: The value can be 0~20.
User-friendly LCD
Charge current limit: The value can be 0.05~0.15, and is 0.1 by default.
Cell float voltage: The float voltage value can be 2.23~2.30 V/cell, and is 2.25 V/cell
by default.
Cell boost voltage: The battery equalized voltage value can be 2.30~2.40 V/cell,
(default: 2.30 V/cell)
Average charging Duration: boost charge time limit, the value can be
1~999min(default:240)
User-friendly LCD
Periodically Automatic Battery Test
 Settable from LCD Display
 Periodically Automatic Battery Test Every 30 Days
 Battery Test Period can be set at 10 seconds, 10 min. or EOD
User-friendly LCD
Firmware version for Monitor & LCD
User-friendly LCD
Service Reminder
Superior MTBF & MTTR
 MTBF: 100,000 hours
 MTTR: <30 Min.
Remote Monitoring and Connectivity Options
50kVA &60kVA
 Front EPO & Remote EPO
 RS232/USB/RS485 Port
 Dry Contact Relay Card/SNMP Card
 LBS Port(Load Bus Synchronization)
 SPD(optional)
Remote Monitoring and Connectivity Options
80kVA/100kVA/120kVA/160kVA
 Front EPO & Remote EPO
 RS232/USB/RS485 Port
 Dry Contact Relay Card/SNMP Card
 LBS Port(Load Bus Synchronization)
 SPD(optional)
Remote Monitoring and Connectivity Options
200kVA
 Front EPO & Remote EPO
 RS232/USB/RS485 Port
 Dry Contact Relay Card/SNMP Card
 LBS Port(Load Bus Synchronization)
 SPD(optional)
EPO & Remote EPO

REPO
RS232/USB/RS485 Port
Dry Contact Relay Card
SNMP Communication Card KPM550
Load Bus Synchronization
Battery Temperature Compensation Kits
 Temperature Compensated Charging Algorithm prevents
battery damage
 Prolong battery lifespan

Via RS485 port


Space-saving and Simple to Service

 Smallest Footprint & High Power Density


 Communication Software
 Remote Panel via RS485
 HP Tools to Export Event Log Data
 Periodically Automatic Battery Test
Smallest Footprint High Power Density
 Reduce the Carbon Footprint of the Installation
 Optimize PUE(Power Usage Effectiveness)

828
mm
m
250m
Remote Panel via RS485
 Via RS485 Modbus Protocol
Communication Software
 Kstar ModBus
 Kstar Setting Tool: Muser 5000
UPSService Tools to Export Event Log Data
 UPSService for event log export
Mains-friendly with Low Input Harmonics
and Advanced PFC
 Low input current THD < 2.71%
 Unity Power Factor
 No Additional Filters required in Upstream
 No Disturbance caused to the equipment connected to

the same input source


 Less Investment in Upstream Cabling, Switchgear and
Generator Size
 Reduce heating of Input Transformers
Low input current THD < 2.71%
Input THDI versus load
6.00

5.00

4.00
THDI(%)

R
3.00 S
T
2.00

1.00

0.00
25% 50% 75% 100%
LOAD(%)

% Load R S T
25% 5.12 5.21 5.19
Input THDI versus 50% 3.10 3.20 3.10
load 75% 2.91 2.93 2.92
2.73 2.71 2.74
100%
Unity Power Factor
Input Power Factor versus load
1.000

0.990

0.980

0.970 R
S
PF

0.960 T

0.950

0.940

0.930
25% 50% 75% 100%

LOAD(%)

% Load R S T
25% 0.960 0.958 0.955
Input Power Factor 50% 0.995 0.996 0.996
versus load 75% 0.999 0.999 0.998
0.999 0.999 0.999
100%
Technical Specifications
 Input
 Output
 Battery
 Charging Current
 Cabling
 Breakers
Input
MODEL YDC3350E YDC3360E YDC3380E YDC33100E YDC33120E YDC33160E YDC33200E

Capacity (VA/Watts) 50K / 50K 60k/60k 80k/80k 100k/100k 120k/120k 160k/160k 200k/200k

INPUT
Nominal voltage 380/400/415Vac, (3Ph+N+PE)
Operating voltage range 138~485Vac
Operating frequency 40Hz-70Hz
range
Power factor ≥0.99
Harmonic distortion ≤3% (100% linear load )
(THDi)
220Vac Max.voltage: +25%(optional +10%,+15%,+20% )
230Vac Max.voltage: +20%(optional +10%,+15% )
Bypass voltage range 240Vac Max.voltage: +15%(optional +10% )
Min. voltage: -45% (optional -20%,-30%)
Frequency synchronize tracing range: ±10%

Generator input Support


Output

MODEL YDC3350E YDC3360E YDC3380E YDC33100E YDC33120E YDC33160E YDC33200E

Capacity (VA/Watts) 50K / 50K 60k/60k 80k/80k 100k/100k 120k/120k 160k/160k 200k/200k

OUTPUT

Rated voltage 380/400/415Vac, (3Ph+N+PE)


Power factor 1

Voltage regulation ±1%

Output Line Mode synchronize with input; when input frequency > ±10% (±1%/±2%/±4%/±5% optional),
output (50/60±0.1%)Hz.
frequency
Bat. Mode (50/60±0.1%)Hz

Crest factor 3:1


Harmonic distortion ≤2% with linear load
(THD) ≤4% with non linear load
Efficiency 95.5%
Battery

MODEL YDC3350E YDC3360E YDC3380E YDC33100E YDC331120E YDC33160E YDC33200E

Capacity (VA/Watts) 50k/50k 60k/60k 80k/80k 100k/100k 120k/120k 160k/160k 200k/200k

BATTERY

Optional Voltage:
±180V/192V/±204V/±216V/±228V/±240/±252/±264/±276/±288/±300Vdc
Battery voltage (30/32/34/36/38/40/42/44/46/48/50pcs optional)
384Vdc~480Vdc (30~40 pcs, 40 pcs default , 32 and 50 pcs no power derating; 30 pcs
output power factor 0.8;)
Charging Current

MODEL YDC3350E YDC3360E YDC3380E YDC33100E YDC33120E YDC33160E YDC33200E

Capacity (VA/Watts) 50k/50k 60k/60k 80k/80k 100k/100k 120k/120k 160k/160k 200k/200k

Charging Current Max. 20A Max. 40A Max. 60A


PHYSICAL

MODEL YDC3350E YDC3360E YDC3380E YDC33100E YDC33120E YDC33160E YDC33200E

Capacity(VA/Watts) 50k/50k 60k/60k 80k/80k 100k/100k 120k/120k 160k/160k 200k/200k

Dimension 250*868*900 442*1200*850


WxHxD(mm)

Net weight (kg) 80 83 144 147 155 190 230


Cabling

Cable Dimension
UPS Frame
AC Input AC Output DC Input Grounding
(mm2) (mm2) (mm2) (mm2)

50kVA 25 16 50 16
60kVA 35 35 50 25
80kVA 50 50 70 35
100KVA 70 50 120 35
120KVA 95 70 150 50
160KVA 120 95 185 70
200KVA 150 100 120*2 95
Breakers

Model YDC3350E YDC3360E YDC3380E YDC33100E YDC33120E YDC33160E YDC33200E

Input Breaker 100A 3P 125A 3P 160A 3P 200A 3P 250A 3P 320A 3P 400A 3P

Output Breaker 100A 3P 125A 3P 160A 3P 200A 3P 250A 3P 320A 3P 400A 3P

Bypass Breaker 100A 3P 125A 3P 160A 3P 200A 3P 250A 3P 320A 3P 400A 3P

Battery Breaker 160A 3P 200A 3P 200A 3P 320A 3P 400A 3P 500A 3P 630A 3P


The End
&