Megapower 3-Level
YDC3300 E Series
Product
ProductPresentation
Presentation
05/2021
Megapower 3-level
YDC 3300 E series
Online UPS System
Pantone Black C; RAL9005
50/60/80/100/120/160/200kVA/kW
3P 4W System
50kW/60kW 80kW/100kW/160kW 200kW
Mission critical & industrial applications
Operator Centres, Servers, Computer rooms,
Telecom Switchgear & Infrastructures,
Processing Control Equipment,
Security Systems, Emergency Lighting, Fire
Protection,
Airport Infrastructure,
Bank, Hospital, Healthcare Equipment …
Main Features
High Reliability
Low Cost of Ownership
Efficient Service Concept
Space-saving and Simple to Service
Mains-friendly with Low Input Harmonics and Advanced PFC
Technical Specifications
High Reliability
True Online Double Conversion with 3-level Inverter
Topology
Energy Control Module for Parallel Control
Redundancy Auxiliary Power Supply and Fans
Conformal Coating on PCB Enables to work in harsh
environment
N+X Parallel Redundancy
Extended Backup Time Availability
High Reliability
Powerful Power Module May provide >30% Charging
Capacity
3-level Intelligent Charging Modes
True Online Double Conversion
Single Line Diagram
Bypass
I/P AC/DC
O/P
EMI BUS DC/AC EMI
Converter Inverter
DC/DC Charger
Converter
Battery
3-level Inverter Topology
Energy Control Module
For Parallel Control
Redundancy Auxiliary Power Supply and Fans
Avoid Single Point of Failure
Support 50% load if one fan is in failure; support 30% load
if two fans are in failure
Redundancy
Conformal Coating on PCB Enables to work in
harsh environment
Can Work under dust, salty & Misty Environment
No derating at 40 C
N+X Parallel Redundancy
Up to 6 UPS can be in Parallel
More than 1 UPS can be in redundancy
Extended Backup Time Availability
Powerful Charger 20A for 50kW/60kW, 40A for
80kW/100kW/120kW & 60A for 150kW/200kW
Matching Battery Cabinet for long backup
Powerful Power Module May provide
>30% Charging Capacity
Max. 20A per 50kW/60kW and 40A for
80kW/100kW/120kW and 60A for 150kW/200kW
No need for additional external charger
40A
20A
3-level Intelligent Charging Modes
Equalized Floating
Boost 0.1C =>10H
0.05C=>20H 0~6H
(Boost Charge 2.30V to 2.35V per cell &Float Charge 2.20V to 2.29V per cell)
Low Cost of Ownership
Up to 95.5% system efficiency
Up to >=99% efficiency in Eco-mode
Rated Output Power Factor 1.0
Near-unity Power factor at partial and full loads
Wide Input Voltage/Frequency Range
Superior Overload Capability
Back feed Protection
De-rating Operation Available
Adjustable Battery Voltage(30 ~50 blocks)
Common Battery
Dual Input Feed
Modular Design Concept for 100K Above
Frequency Converter Mode Is Selectable
Up to 95.5% system efficiency
Efficiency 94.9% from 10% load
Flat Efficiency Curve for a Wide Range of Load
Efficiency η
98
96
94
230V
92 220V
Efficiencyη ( % )
90
88
% Load 230V
86 10% 94.40
20% 95.30
84
30% 95.48
82 40% 95.34
230V 50% 95.51
80 Efficiency (10 60% 95.48
% Load 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
points) 70% 95.37
LOAD(%) 80% 95.23
90% 95.13
Up to >=99% efficiency in Eco-mode
Suitable for good grid area
Transfer time back to online mode: <5ms
High Efficiency of Up to 95.5% at Low Load
High and Constant Efficiency
√ Traditional UPS operates at efficiency below 85% when in parallel configuration
(10% to 50% system load rate)
√ KSTAR UPS achieves 95.3%efficiency at 75% load rate
√ KSTAR UPS achieves 95.5% at 50% load rate
√ KSTAR UPS achieves 95.46% efficiency at 25% above load rate
Efficiencyη ( % )
KSTAR UPS
98.0
95.46 95.50 95.30
96.0 94.75
94.0 5.5% difference
12.5% difference
92.0 Traditional UPS
90.0
88.0
86.0
84.0
82.0
80.0
25% 50% 75% 100%
LOAD(%)
High Efficiency >95.5% at Low Load Rate
Typical load of 200kW , Air-Con COP=3, electric charge=0.16USD/kWh
Legacy UPS Present UPS in the industry KSTAR UPS
UPS Efficiency 85% 90% 92% 94% 95.5%
UPS power dissipation per 309, 176 194, 667 152, 348 111, 830 81158
year(kWh)
Cooling power dissipation 103, 059 64, 889 50, 783 37, 277 27053
per year(kWh)
Total power consumption 412, 235 259, 556 203, 130 149, 106 108,211
per year(KWh)
Total power cost per 66, 336 41, 767 32, 687 23, 994 17413
year(USD)
Power cost over KSTAR UPS 48,923 24,354 15,274 6,581 0
(USD)
Yearly Power Cost/USD
70000
60000
50000 Power consumption
40000 reduced by 76.6%
30000
20000
10000
0
85% 90% 92% 94% 96%
Rated Output Power Factor 1.0
Supply loads from 0.5 leading to 0.5 lagging without de-rating
Can connect 25% more than traditional UPS
Wide Input Voltage/Frequency Range
Voltage Window: 138V~485V
Frequency Window: 40~70Hz
6KV/5KA Lightning Protection
40℃ 323~485V: 100% Load
323~138V: de-rating load
30℃ 305~485V: 100% Load
305~138V: de-rating load
Superior Overload Capability
Inverter: 110% for 60 min., 125% for 10min., 150%
for 1 min., >=1000% for 100ms
Bypass: 135% continuously; >=1000% for 100ms
Back feed Protection
Monitor Bypass SCR status;
Drive the bypass breaker.
UPS Instruction
Pin1 IN or OUT
Pin3 IN or OUT
No bypass contactor built-in
De-rating Operation Available
Temperature: Normal operation at
0~40 C & 12% per 5 C (max. 50 C)
Altitude:
Altitude
(m) 1500 2000 2500 3000 3500 4000 4500 5000
Load
100% 95% 90% 85% 80% 75% 70% 65%
coefficient
Adjustable Battery Voltage(30 ~50blocks)
Flexible Battery voltage, No need to over-size the
batteries
No Interruption might occur when few blocks of the
batteries connected to the same string are broken
• 30 blocks: 0.8PF
• 32-34 blocks: 0.9PF
• 36-50 blocks: 1.0PF
Common Battery
Flexible battery configuration 30~50 blocks
All UPS in Parallel Share One Battery String
Big Saving for Battery Management Investment
Maximize cost Effectiveness
Minimize Floor Space
Battery Cabinet
Battery Voltage v.s. Output Power Factor
30 Blocks 32-34 Blocks 36~50 Blocks
Power Factor 0.8 PF 0.9 PF 1.0 PF
Dual Input Feed
Modular Design Concept for 100K Above
If one of the modules is out of order at <50% load for
100K/120K and 67% load for 150K/180K, the UPS may
work continuously without interruption
Modular design concept saves maintenance cost
For 7” LCD Display Upgrade
RJ485(RJ45)Port on the rear panel
LCD Firmware Upgrade via UPSService software
Efficient Service Concept
Easy Swappable Module with Condition
Fan Replacement from Front
Filter Swap from Front
User-friendly LCD
Superior MTBF & MTTR
Remote Monitoring and Connectivity Options
Filter Swap from Front
User-friendly LCD
Thin film transistor(TFT) LCD
Supports Multi-languages
Real-time Meter Readings of System Currents, Voltages,
Active and Reactive Power
Status Reports and History Files
System Power Flow On-line Diagram
Event log Shown On the Display
1000~10,000 Event Can be Recorded
Event Log can be exported
First-in First-out Principle
User-friendly LCD
Remaining Backup Time on LCD
User-friendly LCD
Basic Setting
Advanced Setting
Password:111111
User-friendly LCD
Basic Setting
Language
Password
Brightness
Time & Period
Communication Setup
Password:111111
User-friendly LCD
Advanced Setting
System
Parallel
Output
Battery
Bypass
Dry Contact
Password:191210
User-friendly LCD
System Setup
User-friendly LCD
Frequency Converter Mode
LBS mode
Float Temperature Compensation
Temperature Sensor Select: NTC and RS485.
p.s. NTC for single and short distance. Rs485 for multiple and far distance.
User-friendly LCD
Inter Power Walk in: Rack to Rack
Inter sleep mode
User-friendly LCD
Parallel ID
Parallel Cabinet Quantity
Redundancy Cabinet Quantity
User-friendly LCD
Battery Group(String)
Battery number: The value can be 30~50, default value is 30.
Single Battery Capability 7AH~2000AH.
Boost/Float conversion: The value can be 0~20.
User-friendly LCD
Charge current limit: The value can be 0.05~0.15, and is 0.1 by default.
Cell float voltage: The float voltage value can be 2.23~2.30 V/cell, and is 2.25 V/cell
by default.
Cell boost voltage: The battery equalized voltage value can be 2.30~2.40 V/cell,
(default: 2.30 V/cell)
Average charging Duration: boost charge time limit, the value can be
1~999min(default:240)
User-friendly LCD
Periodically Automatic Battery Test
Settable from LCD Display
Periodically Automatic Battery Test Every 30 Days
Battery Test Period can be set at 10 seconds, 10 min. or EOD
User-friendly LCD
Firmware version for Monitor & LCD
User-friendly LCD
Service Reminder
Superior MTBF & MTTR
MTBF: 100,000 hours
MTTR: <30 Min.
Remote Monitoring and Connectivity Options
50kVA &60kVA
Front EPO & Remote EPO
RS232/USB/RS485 Port
Dry Contact Relay Card/SNMP Card
LBS Port(Load Bus Synchronization)
SPD(optional)
Remote Monitoring and Connectivity Options
80kVA/100kVA/120kVA/160kVA
Front EPO & Remote EPO
RS232/USB/RS485 Port
Dry Contact Relay Card/SNMP Card
LBS Port(Load Bus Synchronization)
SPD(optional)
Remote Monitoring and Connectivity Options
200kVA
Front EPO & Remote EPO
RS232/USB/RS485 Port
Dry Contact Relay Card/SNMP Card
LBS Port(Load Bus Synchronization)
SPD(optional)
EPO & Remote EPO
REPO
RS232/USB/RS485 Port
Dry Contact Relay Card
SNMP Communication Card KPM550
Load Bus Synchronization
Battery Temperature Compensation Kits
Temperature Compensated Charging Algorithm prevents
battery damage
Prolong battery lifespan
Via RS485 port
Space-saving and Simple to Service
Smallest Footprint & High Power Density
Communication Software
Remote Panel via RS485
HP Tools to Export Event Log Data
Periodically Automatic Battery Test
Smallest Footprint High Power Density
Reduce the Carbon Footprint of the Installation
Optimize PUE(Power Usage Effectiveness)
828
mm
m
250m
Remote Panel via RS485
Via RS485 Modbus Protocol
Communication Software
Kstar ModBus
Kstar Setting Tool: Muser 5000
UPSService Tools to Export Event Log Data
UPSService for event log export
Mains-friendly with Low Input Harmonics
and Advanced PFC
Low input current THD < 2.71%
Unity Power Factor
No Additional Filters required in Upstream
No Disturbance caused to the equipment connected to
the same input source
Less Investment in Upstream Cabling, Switchgear and
Generator Size
Reduce heating of Input Transformers
Low input current THD < 2.71%
Input THDI versus load
6.00
5.00
4.00
THDI(%)
R
3.00 S
T
2.00
1.00
0.00
25% 50% 75% 100%
LOAD(%)
% Load R S T
25% 5.12 5.21 5.19
Input THDI versus 50% 3.10 3.20 3.10
load 75% 2.91 2.93 2.92
2.73 2.71 2.74
100%
Unity Power Factor
Input Power Factor versus load
1.000
0.990
0.980
0.970 R
S
PF
0.960 T
0.950
0.940
0.930
25% 50% 75% 100%
LOAD(%)
% Load R S T
25% 0.960 0.958 0.955
Input Power Factor 50% 0.995 0.996 0.996
versus load 75% 0.999 0.999 0.998
0.999 0.999 0.999
100%
Technical Specifications
Input
Output
Battery
Charging Current
Cabling
Breakers
Input
MODEL YDC3350E YDC3360E YDC3380E YDC33100E YDC33120E YDC33160E YDC33200E
Capacity (VA/Watts) 50K / 50K 60k/60k 80k/80k 100k/100k 120k/120k 160k/160k 200k/200k
INPUT
Nominal voltage 380/400/415Vac, (3Ph+N+PE)
Operating voltage range 138~485Vac
Operating frequency 40Hz-70Hz
range
Power factor ≥0.99
Harmonic distortion ≤3% (100% linear load )
(THDi)
220Vac Max.voltage: +25%(optional +10%,+15%,+20% )
230Vac Max.voltage: +20%(optional +10%,+15% )
Bypass voltage range 240Vac Max.voltage: +15%(optional +10% )
Min. voltage: -45% (optional -20%,-30%)
Frequency synchronize tracing range: ±10%
Generator input Support
Output
MODEL YDC3350E YDC3360E YDC3380E YDC33100E YDC33120E YDC33160E YDC33200E
Capacity (VA/Watts) 50K / 50K 60k/60k 80k/80k 100k/100k 120k/120k 160k/160k 200k/200k
OUTPUT
Rated voltage 380/400/415Vac, (3Ph+N+PE)
Power factor 1
Voltage regulation ±1%
Output Line Mode synchronize with input; when input frequency > ±10% (±1%/±2%/±4%/±5% optional),
output (50/60±0.1%)Hz.
frequency
Bat. Mode (50/60±0.1%)Hz
Crest factor 3:1
Harmonic distortion ≤2% with linear load
(THD) ≤4% with non linear load
Efficiency 95.5%
Battery
MODEL YDC3350E YDC3360E YDC3380E YDC33100E YDC331120E YDC33160E YDC33200E
Capacity (VA/Watts) 50k/50k 60k/60k 80k/80k 100k/100k 120k/120k 160k/160k 200k/200k
BATTERY
Optional Voltage:
±180V/192V/±204V/±216V/±228V/±240/±252/±264/±276/±288/±300Vdc
Battery voltage (30/32/34/36/38/40/42/44/46/48/50pcs optional)
384Vdc~480Vdc (30~40 pcs, 40 pcs default , 32 and 50 pcs no power derating; 30 pcs
output power factor 0.8;)
Charging Current
MODEL YDC3350E YDC3360E YDC3380E YDC33100E YDC33120E YDC33160E YDC33200E
Capacity (VA/Watts) 50k/50k 60k/60k 80k/80k 100k/100k 120k/120k 160k/160k 200k/200k
Charging Current Max. 20A Max. 40A Max. 60A
PHYSICAL
MODEL YDC3350E YDC3360E YDC3380E YDC33100E YDC33120E YDC33160E YDC33200E
Capacity(VA/Watts) 50k/50k 60k/60k 80k/80k 100k/100k 120k/120k 160k/160k 200k/200k
Dimension 250*868*900 442*1200*850
WxHxD(mm)
Net weight (kg) 80 83 144 147 155 190 230
Cabling
Cable Dimension
UPS Frame
AC Input AC Output DC Input Grounding
(mm2) (mm2) (mm2) (mm2)
50kVA 25 16 50 16
60kVA 35 35 50 25
80kVA 50 50 70 35
100KVA 70 50 120 35
120KVA 95 70 150 50
160KVA 120 95 185 70
200KVA 150 100 120*2 95
Breakers
Model YDC3350E YDC3360E YDC3380E YDC33100E YDC33120E YDC33160E YDC33200E
Input Breaker 100A 3P 125A 3P 160A 3P 200A 3P 250A 3P 320A 3P 400A 3P
Output Breaker 100A 3P 125A 3P 160A 3P 200A 3P 250A 3P 320A 3P 400A 3P
Bypass Breaker 100A 3P 125A 3P 160A 3P 200A 3P 250A 3P 320A 3P 400A 3P
Battery Breaker 160A 3P 200A 3P 200A 3P 320A 3P 400A 3P 500A 3P 630A 3P
The End
&