SonoScape
VISTA Platform Ultrasound units
Software Upgrade
Content
SW •Which files need to
introductio
n
upgrade?
•How to get the
Get SW files?
Upgrad •How to upgrade
e SW the files?
Software introduction
SW •Which files need to
introductio
n
upgrade?
Get SW
Upgrad
e SW
Software introduction
Adata
Aconfig
Asecure
Kernel Keypass
System
Software
TP software
Touch panel
Software introduction
Kernel
1.85G
B
Bootable USB Size
disk
Kernel version 1.85GB
13.6
Only complete kernel files can make the upgrade system successful.
Software introduction
Adata
Asecu
re
Common
Software
file Only for one
Control
version unit
number
adata_*.*.*.*.tgz and
asecure******_*.*.*.*.tgz
Software introduction
How to get the Control
Number?
1.From system setting/ 2. VBF board S/N
About interface
Software introduction
Aconfi
g
aconfig8002
58
=
Control number asecure80025
8_3.0.8.1.tgz
This file is the function control file, when we install it to the
unit, the equipment function state will be changed from off to
on. and this file will control the time limited.
Software introduction
Keypa
ss
keypas
s
96CA
Serial number of the u-scan hardware
Software introduction
TP software
Touch panel
Software version
Model code
TpUpdate-1.1.3.081_S40.utp
Get software
SW
introductio
n
Get SW
Update
SW
Get software
What should we do?
1. (Customer) Provide the SN & CN of the
target unit;
2. (SonoScape) Check record and apply the
software;
3. (SonoScape) Send Software to you;
4. (Customer) Get the files and upgrade the
software.
Get software
S/ •Back
N Cover
C/ •System
N setting
Net disk
Get software
Open the Website
Get software
Software version
Control number
Format
TpUpdate-1.1.3.081_S40.utp
Update Instructions
SW
introductio
n
Get SW
Upgrad
e SW
Update Instructions
Software
upgrade
Upgrade kernel and software
Non-kernel upgrade
Update Instructions--Update kernel and
software
Upgrade kernel
and software
Update Instructions--Update kernel and
software
Upgrade
kernel and Total reinstall the
software software
Solve system software
problem
Upgrade the kernel file
to the new version
Update Instructions--Update kernel and
software
Kernel •External USB keyboard
Adata •Bootable USB disk
•Yearly password
asecure
•Empty USB disk
aconfig •Yearly password
•Empty USB disk
keypass •Monthly password
Update Instructions--Update kernel and
software
Attention!
The HDD (hard disk drive) will be formatted, please
back up data before the kernel file upgrade.
Update Instructions--Update kernel and
software
Kernel/adata/asecure
1. Copy the right Adata and Asecure files into the Bootable
USB disk “update” folder.
Update Instructions--Update kernel and
software
2. Use an external USB port keyboard connect with the target
unit USB port (rear cover USB port or front cover USB
port),
USB
port
Update Instructions--Update kernel and
software
3. Plug the bootable USB disk into the target unit USB port
(rear cover USB port or front cover USB port), then
Press power button and boot up the system.
4. When the unit boot up, at the same time, hold the external
keyboard Delete key, when the monitor show us below
interface, input password “service” and press enter key,
the system will enter the BIOS interface.
service
Update Instructions--Update kernel and
software
Set the option as below steps:
Choose Boot:
Boot Boot Option Priorities Boot Option #1 UEFI:
USB drive
Update Instructions--Update kernel and
software
Hard Drive BBS Priorities Boot Option #1 USB drive.
Update Instructions--Update kernel and
software
5. After finish set up the option, save and Exit from
BIOS.
Save & Exit->Save Changes and Exit->Yes
Update Instructions--Update kernel and
software
In the system BIOS mode:
Press “up”, “down”, “left” and “right” key choose the
option;
Press “Enter” key enter the option;
Press “ESC” key Exit the option (back to the last page).
Es
c
Ente
r
Update Instructions--Update kernel and
software
6. The upgrade program will run automatically.
Wait till a prompt message appear.
Kernel Version
A force command
Update Instructions--Update kernel and
software
Different command
Update Instructions--Update kernel and
software
7. Now we input “forcekill” and press Enter key to
continue (external keyboard).
forcekill
Enter
All steps should be
DONE, if FAILED
appear, try “forcekill”
command again, or
change another
Bootable USB disk.
At this step, we may
wait about 5 minutes.
Update Instructions--Update kernel and
software
8. When the monitor show us below message, press Enter key
to shut down the system.
Only press Enter key can
shutdown the system.
9. After system shut down, remove the USB disk and USB
keyboard.
Update Instructions--Update kernel and
software
10. Press power on key boot up the system, and then software
will be installed automatically.
When the system reboot, the
screen will show blue
interface like left image, this
mean the software is
installing, and when it is
finished, system will reboot by
itself, during this time, we just
need to wait.
When the Exam
Exam interfaceinterface appeared,
the upgrade Kernel,
Adata and Asecure
files are finished.
Update Instructions--Update kernel and
software
After install config file,
Message will
automatically
disappear.
Update Instructions--Update kernel and
software
Aconfig file
1. Copy the right Aconfig file into the root directory of
any empty USB disk.
aconfig101261
2. Plug the USB disk into the target unit USB port (rear
USB port or front cover USB port).
Update Instructions--Update kernel and
software
3. Press keyboard Shift, E, MENU keys one by one;
MEN
U
E
Shift
Update Instructions--Update kernel and
software
4. when the monitor show you below left interface. Do the
operation as below steps:
a. input the b. Move trackball to c. Move trackball to
password (yearly software update Exit option and
password) and option and press set press set key;
press enter key; key;
Step a Step b Step c
5. Then the monitor interface will back to the EXAM interface,
remove USB disk;
Update Instructions--Update kernel and
software
Keypass file
1.Copy the right Keypass file into the root directory of any
empty USB disk.
2. Return to the exam interface and plug the USB disk into
the target unit USB port (rear USB port or front cover
USB port).
Update Instructions--Update kernel and
software
3. Press keyboard Shift, E, MENU keys one by one;
MEN
U
E
Shift
Update Instructions--Update kernel and
software
4. when the monitor show you below left interface. Do the
operation as below steps:
a. input the b. Move trackball c. Move trackball to
password to Probe table in Exit option and
(monthly option and press press set key;
password) and set key;
press enter key;
Step a Step b Step c
5. return to the EXAM interface, remove the USB disk;
Update Instructions--Update kernel and
software
6. Shut down and reboot unit to the Exam interfaceActive the u-
scan function
a. At Exam interface, press Menu b. Enter About interface
key
General
Exam interface
About
Menu
Update Instructions--Update kernel and
software
c. follow the right prompt message , press Freeze key, input
password directly (yearly password) and press enter key;
Freeze
About
Yearly
Enter
password
Engineer mode
Update Instructions--Update kernel and
software
d. After enter below engineer f. When the monitor show you
mode, choose dealer config below right interface, the u-
and press set key, then click scan function is activated.
keyboard “i” key.
Dealer config
After above all steps,
Return to the Exam interface and
Reboot the unit, then with-kernel
software upgrade is finished.
Update Instructions--Non-kernel update
Non-kernel
upgrade
Update Instructions--Non-kernel update
Non-kernel upgrade
Kernel Version is
not changed
System can work
normally
Get new functions
Update Instructions--Non-kernel update
adata •Empty USB disk
asecure •Yearly password
•Empty USB disk
aconfig •Yearly password
•Empty USB disk
keypass •Monthly password
Update Instructions--Non-kernel update
adata/asecure
1. Copy the right Adata and Asecure files into the root
directory of any empty USB disk.
Update Instructions--Non-kernel update
2. Boot up the unit, and wait until the EXAM interface
appears, then plug the USB disk to the target unit USB
port (rear cover or front side).
USB
port
Update Instructions--Non-kernel update
3. Press keyboard Shift, E, MENU keys one by one;
MEN
U
E
Shift
Update Instructions--Non-kernel update
4. when the monitor show you below left interface. Do the
operation as below steps:
a. input the b. Move trackball to c. Move trackball to
password (yearly software update Exit option and
password) and option and press set press set key;
press enter key; key;
Step a Step b Step c
Update Instructions--Non-kernel update
5. Then the monitor interface will back to the EXAM
screen;
6. Remove the USB disk and reboot the target unit;
the software will be installed automatically.
When the system reboot, the
screen will show blue interface like
left image, this mean the software
is installing, and when it is
finished, system will reboot by
itself, during this time, we just
need to wait.
When the Exam
Exam interfaceinterface appeared,
the update Adata and
Asecure files are
finished.
Update Instructions--Non-kernel update
aconfig
1. Copy the right Aconfig file into the root directory
of any empty USB disk.
aconfig101261
2. Plug the USB disk into the target unit USB port (rear
USB port or front cover USB port).
Update Instructions--Non-kernel update
3. Press keyboard Shift, E, MENU keys one by one;
MEN
U
E
Shift
Update Instructions--Non-kernel update
4. when the monitor show you below left interface. Do the
operation as below steps:
a. input the b. Move trackball c. Move trackball to
password (yearly to software Exit option and
password) and update option and press set key;
press enter key; press set key;
Step a Step b Step c
5. Then the monitor interface will back to the EXAM interface,
remove USB disk;
Update Instructions--Non-kernel update
keypass
1.Copy the right Keypass file into the root directory of any
empty USB disk.
2. Back to the exam interface and Plug the USB disk into the
target unit USB port (rear USB port or front cover
USB port).
Update Instructions--Non-kernel update
3. Press keyboard Shift, E, MENU keys one by one;
MEN
U
E
Shift
Update Instructions--Non-kernel update
4. when the monitor show you below left interface. Do the
operation as below steps:
a. input the b. Move trackball c. Move trackball to
password to Probe table in Exit option and
(monthly option and press press set key;
password) and set key;
press enter key;
Step a Step b Step c
5. return to the EXAM interface, remove the USB disk;
Update Instructions--Non-kernel update
6. Active the u-scan function
a. At Exam interface, press Menu b. Enter about interface
key
General
Exam interface
About
Menu
Update Instructions--Non-kernel update
c. follow the right prompt message , press Freeze key, input
password directly (yearly password) and press enter key;
Freeze
About
Yearly
Enter
password
Engineer mode
Update Instructions--Non-kernel update
d. After enter below engineer f. When the monitor show you
mode, choose dealer config below right interface, the u-
and press set key, then click scan function is activated.
keyboard “i” key.
Dealer config
After above all steps,
Exit to the Exam interface and
Reboot the system, then non-kernel
software upgrade is finished.
S40 touch panel software
upgrade
TP (touch panel)
S40 Touch screen software update
1. Boot up the S40 unit to the EXAM interface.
2. Press TP key long time then the touch panel will
show us like below right image.
TP (touch panel)
S40 Touch screen software update
3. Copy the software into an empty USB disk root
directory.
4. Plug the USB disk to the touch panel left side USB
port. Then the touch panel will show us USB icon.
S40 Touch screen software update
5. Use your finger click touch panel “system update”
Then wait… not do any other operation for the unit.
Wait about five minutes.
S40 Touch screen software update
After software
upgrade, the screen
will show us Update
Finished, Restart!
Then exit and reboot
the S40.
S40 Touch screen software update
6. Boot up the S40 to the EXAM interface.
7. Press TP key long time then the touch panel will
show us like below right image, and click Touch
Adjust;
TP (touch panel)
S40 Touch screen software update
Click the Cross icon and finish the adjust;
S40 Touch screen software update
Then exit to the probe choose interface, and you can
use your unit now.
How to make bootable USB
disk
Size
1.85GB
Bootable USB
disk
Kernel version
13.6
Only complete kernel files can make the update system successful.
How to make the Bootable USB disk
1. Boot up the PC then put the Bootable DVD disk into the
PC DVD writer;
e r ne l
K
Kernel 13 .
6
13.6
How to make the Bootable USB disk
2. Shut down the PC and plug the empty USB driver in to
PC USB port;
3. Reboot the PC;
4. Enter the PC BIOS and choose the PC boot up from the
CD;
How to make the Bootable USB disk
5. The program will13.6
runs automatically, waiting…
when the screen show us like below image, press “enter”
key to continue.
13.6
13.6
Then the screen will show us like below image.
How to make the Bootable USB disk
6. Waiting, when screen show us “Press enter key to
shutdown:” , press “enter” key to shut down your PC.
7. After PC shut down, remove the USB drive.
8. Boot up the PC, and remove the Bootable CD disk.
How to make the Bootable USB disk
9. Check the Bootable USB disk:
a. There are three folders and four files in the bootable
USB disk root directly;
b. the size of bootable USB disk 13.6v: 1.86 GB
Size
1.85GB