FilFil
Simply Quality
Greyhound Q-Fil Syringe Filters
YOUR GLOBAL SCIENCE PARTNER
RangeRange
As a trusted name in the supply of chromatography
consumables and certified reference standards, Greyhound also
offers a comprehensive selection of top quality own brand
Capillary columns and HPLC columns. This catalogue contains
details of the Q-Fil range of Syringe Filters. Other product
catalogues are available on request.
These quality products are backed by the guaranteed reliability
and technical support which has become synonymous with the
name Greyhound.
Visit our website at: www.greyhoundchrom.com for details of
our full range of products.
Welcome to a new era in analyte detection and
column performance.
Greyhound
Your Global Science Partner
Q-Fil Syringe Filters set the new Quality standard for today’s
laboratory syringe filters. Manufactured from the highest quality
medical grade, high density polypropylene. Q-Fil Syringe Filters
provide excellent chemical compatibility with acids, alcohols,
bases, ethers, glycols, ketones and oils.
Every colour-coded filter is printed with details of the membrane
material and its pore size on the outside of the filter and every
box is labelled with the batch number making them ideal for
traceability, GLPs and validation purposes.
Greyhound Q-Fil Syringe
Filters
Q-Fil Syringe Filters
Q-Cap Capillary Columns
Q-Col HPLC Columns
GC Septa and Ferrules
FilFil
SYRINGE FILTERS BY GREYHOUND
Certificate of Conformance • Disposable Syringe Filters
Greyhound Chromatography and Allied Chemicals
6 Kelvin Park Birkenhead Merseyside CH41 1LT England
Tel: +44 (0) 151 649 4000 Fax: +44-(0) 151 649 4001
Email: info@greyhoundchrom.com Web: www.greyhoundchrom.com
This product complies with all Q-Fil Syringe Filter manufacturing specifications and was
produced in accordance with ISO 9001 Quality Management System
Product Q-Fil Syringe Filter
Part Number 40-100001
Lot Number SM280616
Filter Material Hydrophilic Nylon 0.45µm
Housing Material Polypropylene
Membrane Diameter 25mm
Test Specifications
Visual Inspection Absence of External defects
Luer Lock Female Luer-Lock Inlet, Male
Slip Outlet
Bubble Point 29 psi
Burst Pressure 87 psi
Filtration Area 4.08 cm3
Holdup Volume <100μL
Volume Throughput 100mL
Q-Fil Certificate of Conformance
GREYHOUND Q-Fil SYRINGE FILTERS
1
Why filter your
samples for
HPLC?
The main source of particle contamination in HPLC columns originate in the sample to be analysed.
Therefore, the final preparation step prior to sample injection into the HPLC instrument is to remove any small
particulates from the sample by filtration. Removal of the solid materials is very important as they can interfere
with the compound of interest and easily clog up the column being used. This will inevitably have a
detrimental effect on the performance of the column, i.e. back pressure, peak size, retention time, peak shape.
Severe contamination can lead to the column being irreversibly blocked and therefore having to be replaced.
Other costs can include instrument downtime, and the loss of valuable samples.
Sample Types
Samples differ in a variety of ways, they may be heavily loaded with fine or coarse particulates, dissolved in
aqueous or organic solvents with varying viscosities. To facilitate the most appropriate sample preparation
result, filters should be optimised to match the particular requirements of each kind of sample being injected.
Standard Samples
A matrix of 5-10mL is the most common sample volume, with low viscosity, low particle contamination and
dissolved in either an organic or an aqueous solvent. Greyhound Q-Fil Regenerated Cellulose Syringe Filters
are an excellent choice for such samples. Their inert housing manufactured from high density medical grade
virgin polypropylene, complete with the integrated Regenerated Cellulose (RC) membrane has a high chemical
resistance against the most common HPLC solvents and is very suitable for aqueous samples. Every batch
is HPLC-tested for low extractables. Whilst 0.45µm is the most commonly used membrane porosity, the
0.22µm membrane provides improved purity when using capillary columns or HPLC packings with a
particle size of 3µm or less
Demanding Samples
More difficult samples which contain high loads of particulates, high viscosity or unusually high volumes
place additional challenges on the user when preparing samples for HPLC analysis. The particles have a
tendency to block the filter, high viscosities will decrease the flow rate and high volumes increase the time
required to complete the filtration process. These challenges often result in the user applying a greater degree
of manual pressure to the process and potentially exceeding the maximum pressure limit of the filter with a
subsequent risk of bursting the housing. As a result, the sample will be lost and a potential safety risk can
arise if corrosive solvents or harmful chemicals are being filtered. To assist in overcoming these challenges,
the use of Q-Fil Syringe Filters with a built in Glass Microfiber pre-filter are recommended. The pre-filter
removes the larger particulates from the sample leaving only the smaller particulates to be filtered by the
membrane. These filters increase the flow rate through the unit resulting in a higher volume of sample to be
filtered and less pressure being required by the user.
Small Volume Samples
Smaller volume samples are often valuable and require special attention. Any loss of the analyte due to
adsorption by the filter membrane or housing or a large dead volume can have a detrimental effect on the
analysis. Smaller filters of 13mm and 4mm diameter decrease the dead volume to less than 25uL and 8uL
respectively making them ideal for smaller volume samples.
Summary
Sample filtration is an important factor in ensuring that HPLC analysis is achieved in an efficient and cost
effective way. The extensive range of Q-Fil Syringe Filters have been developed to meet the demands of the
analyst and the different sample matrices being used and without losing any of the important sample.
Why use
Greyhound
Q-Fil Syringe
Filters?
• Every batch of filters is manufactured and tested in accordance with strict ISO 9001:2015 quality procedures
• Every individual Q-Fil Syringe Filter is visually inspected to ensure it meets our manufacturing and quality
control specifications
• Each batch of filters is tested prior to release for:
- External Dimensions - Bubble Point - Water Flow Rate - UV Extractables
- Burst Pressure and compliance - Filter Integrity
About our
Quality Control
procedures
• Every box is supplied with a Certificate of Conformance to guarantee its batch to batch quality
and performance
• The unique encapsulating process developed for these filters, forces the sample to pass only through the
membrane, thus avoiding the possibility of leaks or contamination
• Available in the most popular sizes, porosities and membrane types
• Excellent resistance to all routinely used HPLC solvents
• Filter housings are manufactured from the highest quality medical grade, high density polypropylene
• Extremely low level of extractables for highly sensitive work
• Luer connections fully comply with ISO 594-1
GREYHOUND Q-Fil SYRINGE FILTERS
30mm Dia
25mm Dia
13mm Dia
4mm Dia
2
Designed for the largest sample volumes or solvent filtration
Filtration area 5.39cm2
Maximum filtration volume <200ml
Maximum operating pressure 87psi (6.0 bar) at 20°C
Sample volume <200ml
Holdup volume <200µl
Designed for larger sample volumes or solvent filtration
Filtration area 4.08cm2
Maximum filtration volume >100ml
Maximum operating pressure 87psi (6.0 bar) at 20°C
Sample volume <100ml
Holdup volume <100µl
Suitable for most applications
Filtration area 1.09cm2
Maximum filtration volume >10ml
Maximum operating pressure 87psi (6.0 bar) at 20°C
Sample volume <10ml
Holdup volume <25µl
Suitable for smaller volume applications
Filtration area 0.1cm2
Maximum filtration volume <2ml
Maximum operating pressure 75psi (5.0 bar) at 20°C
Sample volume <2ml
Holdup volume <8ul
• Choose the size of filter based on the volume of sample to be filtered
• Choose the filters porosity based on the size of the potential particulates in the sample. It is important to be
aware that the finer the porosity of the membrane the greater the pressure will be required to pass the sample
through the filter. A sample containing large quantities of particulates is best filtered using a filter with a built-in
glass microfiber pre-filter
• Choose the type of membrane based on the solvent being filtered
Selecting the
right Q-Fil
Syringe Filter
GREYHOUND Q-Fil SYRINGE FILTERS
30mm Dia
25mm Dia
13mm Dia
4mm Dia
2
Designed for the largest sample volumes or solvent filtration
Filtration area 5.39cm2
Maximum filtration volume <200ml
Maximum operating pressure 87psi (6.0 bar) at 20°C
Sample volume <200ml
Holdup volume <200µl
Designed for larger sample volumes or solvent filtration
Filtration area 4.08cm2
Maximum filtration volume >100ml
Maximum operating pressure 87psi (6.0 bar) at 20°C
Sample volume <100ml
Holdup volume <100µl
Suitable for most applications
Filtration area 1.09cm2
Maximum filtration volume >10ml
Maximum operating pressure 87psi (6.0 bar) at 20°C
Sample volume <10ml
Holdup volume <25µl
Suitable for smaller volume applications
Filtration area 0.1cm2
Maximum filtration volume <2ml
Maximum operating pressure 75psi (5.0 bar) at 20°C
Sample volume <2ml
Holdup volume <8ul
• Choose the size of filter based on the volume of sample to be filtered
• Choose the filters porosity based on the size of the potential particulates in the sample. It is important to be
aware that the finer the porosity of the membrane the greater the pressure will be required to pass the sample
through the filter. A sample containing large quantities of particulates is best filtered using a filter with a built-in
glass microfiber pre-filter
• Choose the type of membrane based on the solvent being filtered
Selecting the
right Q-Fil
Syringe Filter
4
GREYHOUND Q-Fil SYRINGE FILTERS
Syringe Filter Membrane Compatibility Chart
Chemical Nylon PTFE PVDF PES CA RC PP GMF
ACIDS
Acetic, Glacial LC C C C IC C C C
Acetic, 25% C C C C CA C C C
Hydrochloric, Concentrated IC C C C IC IC C C
Hydrochloric, 25% IC C C C IC IC C C
Sulphuric, Concentrated IC C IC IC IC IC C C
Sulphuric, 25% IC C C C IC LC C C
Nitric, Concentrated IC C C IC IC IC C LC
Nitric, 25% IC C C C IC IC C LC
Phosphoric, 25% IC C ND ND CA LC C ND
Formic, 25% IC C ND ND LC C C C
Trichloroacetic, 10% IC C ND ND CA C C ND
ALCOHOLS
Methanol, 98% C C C C C C C C
Ethanol, 98% C C C C C C C C
Ethanol, 70% IC C C C C C C C
Isopropanol C C C C C C C C
n-Propanol C C C C C C C C
Amyl Alcohol (Butanol) C C C C C C C C
Benzyl Alcohol C C C ND LC C C IC
Ethylene Glycol C C C C C C C C
Propylene Glycol C C C C LC C C C
Clycerol C C C C C C C C
ALKALIS
Ammonium Hydroxide, 25% C C LC C C LC C C
Sodium Hydroxide, 3N C C C C IC LC C IC
AMINES AND AMIDES
Dimethyl Formamide LC C IC IC IC LC C C
Diethylacetamide C C ND ND IC C ND C
Triethanolamine C C ND ND C C ND ND
Aniline ND C ND ND IC C ND ND
Pyridine C C IC IC IC C IC C
Acetonitrile C C C LC IC C C C
ESTERS
Ethyl Acetate/Methyl Acetate C C C IC IC C LC C
Amyl Acetate/Butyl Acetate C C IC IC LC C LC C
Propyl Acetate C C IC IC LC C LC ND
Propylene Glycol Acetate ND C ND IC IC C C ND
2-Ethoxyethyl Acetate ND C ND IC LC C ND ND
Methyl Cellusolve ND C ND IC IC C C C
Use this information to determine the ability of a specific syringe filter membrane to withstand exposure to solvent.
All concentrations are 100% unless noted.
5
GREYHOUND Q-Fil SYRINGE FILTERS
Chemical Nylon PTFE PVDF PES CA RC PP GMF
ESTERS
Benzyl Benzoate C C ND IC C C ND ND
Isopropyl Myristate C C ND IC C C ND ND
Tricresyl Phosphate ND C ND IC C C ND ND
HALOGENATED HYDROCARBONS
Methylene Chloride LC C C IC IC C LC C
Chloroform C C C IC IC C LC C
Trichloroethylene C C C IC C C C C
Chlorobenzene C C C IC C C C C
Freon C C C IC C C C C
Carbon Tetrachloride C C C IC LC C LC C
HYDROCARBONS
Hexane/Xylene C C C IC C C IC C
Toluene/Benzene C C C IC C C IC C
Kerosene/Gasoline C C C LC C C LC ND
Tetralin/Decalin ND C C ND C C ND ND
KETONES
Acetone C C IC IC IC C C C
Cyclohexanone C C IC IC IC C C C
Methyl Ethyl Ketone C C IC IC LC C LC C
Isopropylacetone C C IC IC C C ND C
Methyl Isobutyl Ketone ND C IC IC ND C LC C
ORGANIC OXIDES
Ethyl Ether C C C C C C LC ND
Dioxane C C LC IC I C C C
Tetrahydrofuran C C LC IC I C C C
Triethanolamine C C ND ND C C ND ND
Dimethylsulfoxide (DMSO) C C IC IC I C C C
Isopropyl Ether ND C C C C C C ND
MISCELLANEOUS
Phenol,Aqueous Solution 10% ND C LC IC IC IC C C
Formaldehyde Aqueous C C C C C LC C C
Solution 30%
Hydrogen Peroxide 30% C C ND ND C C ND ND
Silicone Oil/Mineral Oil ND C C C C C C C
LEGEND
PVDF Polyvinylidene
PES Polyethersulfone
CA Cellulose Acetate
RC Regenerated Cellulose
PP Polypropylene
GMF Glass MicroFibre
C Compatible
LC Limited Compatibility (membrane
may swell and shrink)
IC Incompatible (not recommended)
ND No compatibility data currently available
PTFE Polytetrafluoroethylene (Teflon®)
6
GREYHOUND Q-Fil SYRINGE FILTERS
NYLON
• Hydrophilic membrane
• Excellent for HPLC samples and general filtration
• Compatible with organic and aqueous liquids
• Good solvent resistance and high protein retention
• Strong mechanical stability
Not suitable for use with strong acids or bases, halogenated hydrocarbons or protein
Cat. No. Description Colour Pack
40-100007
40-100008
40-100004
40-100003
40-100002
40-100001
40-100006
40-100005
Nylon Syringe Filters, 0.22µm, 4mm Clear 100
Nylon Syringe Filters, 0.45µm, 4mm Clear 100
Nylon Syringe Filters, 0.22µm, 13mm Blue 100
Nylon Syringe Filters, 0.45µm, 13mm Blue 100
Nylon Syringe Filters, 0.22µm, 25mm Blue 100
Nylon Syringe Filters, 0.45µm, 25mm Blue 100
Nylon Syringe Filters, 0.22µm, 30mm Blue 100
Nylon Syringe Filters, 0.45µm, 30mm Blue 100
40-100004-PF
40-100003-PF
40-100002-PF
40-100001-PF
40-100006-PF
40-100005-PF
Nylon Syringe Filters, 0.22µm, 13mm, with pre-filter Blue 100
Nylon Syringe Filters, 0.45µm, 13mm, with pre-filter Blue 100
Nylon Syringe Filters, 0.22µm, 25mm, with pre-filter Blue 100
Nylon Syringe Filters, 0.45µm, 25mm, with pre-filter Blue 100
Nylon Syringe Filters, 0.22µm, 30mm, with pre-filter Blue 100
Nylon Syringe Filters, 0.45µm, 30mm, with pre-filter Blue 100
40-100004-S
40-100003-S
40-100002-S
40-100001-S
40-100006-S
40-100005-S
Nylon Syringe Filters, 0.22µm, 13mm, Sterile Blue 100
Nylon Syringe Filters, 0.45µm, 13mm, Sterile Blue 100
Nylon Syringe Filters, 0.22µm, 25mm, Sterile Blue 100
Nylon Syringe Filters, 0.45µm, 25mm, Sterile Blue 100
Nylon Syringe Filters, 0.22µm, 30mm, Sterile Blue 100
Nylon Syringe Filters, 0.45µm, 30mm, Sterile Blue 100
Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com
7
GREYHOUND Q-Fil SYRINGE FILTERS
Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com
CELLULOSE ACETATE
• Hydrophilic membrane
• Ideal for aqueous based samples, tissue culture media filtration and sensitive
biological samples
• Very low protein binding membrane, lower than PVDF and PES membranes
• Lower chemical resistance than Regenerated Cellulose
Not suitable for use with organic solvents
Cat. No. Description Colour Pack
40-100330
40-100331
40-100063
40-100062
40-100061
40-100060
40-100065
40-100064
Cellulose Acetate Syringe Filters, 0.22µm, 4mm Clear 100
Cellulose Acetate Syringe Filters, 0.45µm, 4mm Clear 100
Cellulose Acetate Syringe Filters, 0.22µm, 13mm Orange 100
Cellulose Acetate Syringe Filters, 0.45µm, 13mm Orange 100
Cellulose Acetate Syringe Filters, 0.22µm, 25mm Orange 100
Cellulose Acetate Syringe Filters, 0.45µm, 25mm Orange 100
Cellulose Acetate Syringe Filters, 0.22µm, 30mm Orange 100
Cellulose Acetate Syringe Filters, 0.45µm, 30mm Orange 100
40-100063-PF
40-100062-PF
40-100061-PF
40-100060-PF
40-100065-PF
40-100064-PF
40-100063-S
40-100062-S
40-100061-S
40-100060-S
40-100065-S
40-100064-S
Cellulose Acetate Syringe Filters, 0.22µm, 13mm, with pre-filter Orange 100
Cellulose Acetate Syringe Filters, 0.45µm, 13mm, with pre-filter Orange 100
Cellulose Acetate Syringe Filters, 0.22µm, 25mm, with pre-filter Orange 100
Cellulose Acetate Syringe Filters, 0.45µm, 25mm, with pre-filter Orange 100
Cellulose Acetate Syringe Filters, 0.22µm, 30mm, with pre-filter Orange 100
Cellulose Acetate Syringe Filters, 0.45µm, 30mm, with pre-filter Orange 100
Cellulose Acetate Syringe Filters, 0.22µm, 13mm, Sterile Orange 100
Cellulose Acetate Syringe Filters, 0.45µm, 13mm, Sterile Orange 100
Cellulose Acetate Syringe Filters, 0.22µm, 25mm, Sterile Orange 100
Cellulose Acetate Syringe Filters, 0.45µm, 25mm, Sterile Orange 100
Cellulose Acetate Syringe Filters, 0.22µm, 30mm, Sterile Orange 100
Cellulose Acetate Syringe Filters, 0.45µm, 30mm, Sterile Orange 100
8
GREYHOUND Q-Fil SYRINGE FILTERS
Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com
PTFE (HYDROPHOBIC)
• Hydrophobic membrane resistant to strong acids, aggressive solvents,
alcohols, bases and aromatics
• Ideal for the filtration and degassing of chromatography solvents and
for extremely basic mobile phase solutions
• Very low extractables
• Mechanically strong
• Excellent thermal stability
Cat. No. Description Colour Pack
40-100300
40-100301
40-100017
40-100016
40-100015
40-100014
40-100019
40-100018
PTFE Hydrophobic Syringe Filters, 0.22µm, 4mm Clear 100
PTFE Hydrophobic Syringe Filters, 0.45µm, 4mm Clear 100
PTFE Hydrophobic Syringe Filters, 0.22µm, 13mm Red 100
PTFE Hydrophobic Syringe Filters, 0.45µm, 13mm Red 100
PTFE Hydrophobic Syringe Filters, 0.22µm, 25mm Red 100
PTFE Hydrophobic Syringe Filters, 0.45µm, 25mm Red 100
PTFE Hydrophobic Syringe Filters, 0.22µm, 30mm Red 100
PTFE Hydrophobic Syringe Filters, 0.45µm, 30mm Red 100
40-100017-PF
40-100016-PF
40-100015-PF
40-100014-PF
40-100019-PF
40-100018-PF
PTFE Hydrophobic Syringe Filters, 0.22µm, 13mm, with pre-filter Red 100
PTFE Hydrophobic Syringe Filters, 0.45µm, 13mm, with pre-filter Red 100
PTFE Hydrophobic Syringe Filters, 0.22µm, 25mm, with pre-filter Red 100
PTFE Hydrophobic Syringe Filters, 0.45µm, 25mm, with pre-filter Red 100
PTFE Hydrophobic Syringe Filters, 0.22µm, 30mm, with pre-filter Red 100
PTFE Hydrophobic Syringe Filters, 0.45µm, 30mm, with pre-filter Red 100
40-100017-S
40-100016-S
40-100015-S
40-100014-S
40-100019-S
40-100018-S
PTFE Hydrophobic Syringe Filters, 0.22µm, 13mm, Sterile Red 100
PTFE Hydrophobic Syringe Filters, 0.45µm, 13mm, Sterile Red 100
PTFE Hydrophobic Syringe Filters, 0.22µm, 25mm, Sterile Red 100
PTFE Hydrophobic Syringe Filters, 0.45µm, 25mm, Sterile Red 100
PTFE Hydrophobic Syringe Filters, 0.22µm, 30mm, Sterile Red 100
PTFE Hydrophobic Syringe Filters, 0.45µm, 30mm, Sterile Red 100
PTFE (HYDROPHILIC)
• Hydrophilic membrane compatible with aqueous, organic solvents,
strong acids and alkalis
• Mechanically strong
• Excellent thermal stability
• Low protein binding
9
GREYHOUND Q-Fil SYRINGE FILTERS
Cat. No. Description Colour Pack
40-100310
40-100311
40-100312
40-100313
40-100314
40-100315
40-100316
40-100317
40-100312-PF
40-100313-PF
40-100314-PF
40-100315-PF
40-100316-PF
40-100317-PF
40-100312-S
40-100313-S
40-100314-S
40-100315-S
40-100316-S
40-100317-S
PTFE Hydrophilic Syringe Filters, 0.22µm, 4mm Clear 100
PTFE Hydrophilic Syringe Filters, 0.45µm, 4mm Clear 100
PTFE Hydrophilic Syringe Filters, 0.22µm, 13mm Red 100
PTFE Hydrophilic Syringe Filters, 0.45µm, 13mm Red 100
PTFE Hydrophilic Syringe Filters, 0.22µm, 25mm Red 100
PTFE Hydrophilic Syringe Filters, 0.45µm, 25mm Red 100
PTFE Hydrophilic Syringe Filters, 0.22µm, 30mm Red 100
PTFE Hydrophilic Syringe Filters, 0.45µm, 30mm Red 100
PTFE Hydrophilic Syringe Filters, 0.22µm, 13mm, with pre-filter Red 100
PTFE Hydrophilic Syringe Filters, 0.45µm, 13mm, with pre-filter Red 100
PTFE Hydrophilic Syringe Filters, 0.22µm, 25mm, with pre-filter Red 100
PTFE Hydrophilic Syringe Filters, 0.45µm, 25mm, with pre-filter Red 100
PTFE Hydrophilic Syringe Filters, 0.22µm, 30mm, with pre-filter Red 100
PTFE Hydrophilic Syringe Filters, 0.45µm, 30mm, with pre-filter Red 100
PTFE Hydrophilic Syringe Filters, 0.22µm, 13mm, Sterile Red 100
PTFE Hydrophilic Syringe Filters, 0.45µm, 13mm, Sterile Red 100
PTFE Hydrophilic Syringe Filters, 0.22µm, 25mm, Sterile Red 100
PTFE Hydrophilic Syringe Filters, 0.45µm, 25mm, Sterile Red 100
PTFE Hydrophilic Syringe Filters, 0.22µm, 30mm, Sterile Red 100
PTFE Hydrophilic Syringe Filters, 0.45µm, 30mm, Sterile Red 100
Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com
10
GREYHOUND Q-Fil SYRINGE FILTERS
Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com
PVDF (HYDROPHOBIC)
• Polyvinylidene difluoride membrane, hydrophobic
• Resistant to solvents, exhibits low levels of extractables
• Low protein binding membrane, can be used with proteins
and peptides
• Suitable for filtration of aqueous and organic solvents
• Ideal for HPLC and general biological filtration
Cat. No. Description Colour Pack
40-100360
40-100361
40-100362
40-100363
40-100364
40-100365
40-100366
40-100367
40-100362-PF
40-100363-PF
40-100364-PF
40-100365-PF
40-100366-PF
40-100367-PF
40-100362-S
40-100363-S
40-100364-S
40-100365-S
40-100366-S
40-100367-S
PVDF Hydrophobic Syringe Filters, 0.22µm, 4mm Clear 100
PVDF Hydrophobic Syringe Filters, 0.45µm, 4mm Clear 100
PVDF Hydrophobic Syringe Filters, 0.22µm, 13mm Yellow 100
PVDF Hydrophobic Syringe Filters, 0.45µm, 13mm Yellow 100
PVDF Hydrophobic Syringe Filters, 0.22µm, 25mm Yellow 100
PVDF Hydrophobic Syringe Filters, 0.45µm, 25mm Yellow 100
PVDF Hydrophobic Syringe Filters, 0.22µm, 30mm Yellow 100
PVDF Hydrophobic Syringe Filters, 0.45µm, 30mm Yellow 100
PVDF Hydrophobic Syringe Filters, 0.22µm, 13mm, with pre-filter Yellow 100
PVDF Hydrophobic Syringe Filters, 0.45µm, 13mm, with pre-filter Yellow 100
PVDF Hydrophobic Syringe Filters, 0.22µm, 25mm, with pre-filter Yellow 100
PVDF Hydrophobic Syringe Filters, 0.45µm, 25mm, with pre-filter Yellow 100
PVDF Hydrophobic Syringe Filters, 0.22µm, 30mm, with pre-filter Yellow 100
PVDF Hydrophobic Syringe Filters, 0.45µm, 30mm, with pre-filter Yellow 100
PVDF Hydrophobic Syringe Filters, 0.22µm, 13mm, Sterile Yellow 100
PVDF Hydrophobic Syringe Filters, 0.45µm, 13mm, Sterile Yellow 100
PVDF Hydrophobic Syringe Filters, 0.22µm, 25mm, Sterile Yellow 100
PVDF Hydrophobic Syringe Filters, 0.45µm, 25mm, Sterile Yellow 100
PVDF Hydrophobic Syringe Filters, 0.22µm, 30mm, Sterile Yellow 100
PVDF Hydrophobic Syringe Filters, 0.45µm, 30mm, Sterile Yellow 100
11
GREYHOUND Q-Fil SYRINGE FILTERS
Cat. No. Description Colour Pack
40-100320
40-100321
40-100033
40-100032
40-100031
40-100030
40-100035
40-100034
PVDF Hydrophilic Syringe Filters, 0.22µm, 4mm Clear 100
PVDF Hydrophilic Syringe Filters, 0.45µm, 4mm Clear 100
PVDF Hydrophilic Syringe Filters, 0.22µm, 13mm Yellow 100
PVDF Hydrophilic Syringe Filters, 0.45µm, 13mm Yellow 100
PVDF Hydrophilic Syringe Filters, 0.22µm, 25mm Yellow 100
PVDF Hydrophilic Syringe Filters, 0.45µm, 25mm Yellow 100
PVDF Hydrophilic Syringe Filters, 0.22µm, 30mm Yellow 100
PVDF Hydrophilic Syringe Filters, 0.45µm, 30mm Yellow 100
40-100033-PF
40-100032-PF
40-100031-PF
40-100030-PF
40-100035-PF
40-100034-PF
40-100033-S
40-100032-S
40-100031-S
40-100030-S
40-100035-S
40-100034-S
PVDF Hydrophilic Syringe Filters, 0.22µm, 13mm, with pre-filter Yellow 100
PVDF Hydrophilic Syringe Filters, 0.45µm, 13mm, with pre-filter Yellow 100
PVDF Hydrophilic Syringe Filters, 0.22µm, 25mm, with pre-filter Yellow 100
PVDF Hydrophilic Syringe Filters, 0.45µm, 25mm, with pre-filter Yellow 100
PVDF Hydrophilic Syringe Filters, 0.22µm, 30mm, with pre-filter Yellow 100
PVDF Hydrophilic Syringe Filters, 0.45µm, 30mm, with pre-filter Yellow 100
PVDF Hydrophilic Syringe Filters, 0.22µm, 13mm, Sterile Yellow 100
PVDF Hydrophilic Syringe Filters, 0.45µm, 13mm, Sterile Yellow 100
PVDF Hydrophilic Syringe Filters, 0.22µm, 25mm, Sterile Yellow 100
PVDF Hydrophilic Syringe Filters, 0.45µm, 25mm, Sterile Yellow 100
PVDF Hydrophilic Syringe Filters, 0.22µm, 30mm, Sterile Yellow 100
PVDF Hydrophilic Syringe Filters, 0.45µm, 30mm, Sterile Yellow 100
Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com
PVDF (HYDROPHILIC)
• Modified Polyvinylidene difluoride membrane, hydrophilic
• Resistant to solvents, acids and chemicals
• Very low protein and preservative binding
• Clarification and purification of aqueous and organic solvents, acids and bases
• Filtration of antibiotics, diagnostics, serum, culture media and vaccines
12
GREYHOUND Q-Fil SYRINGE FILTERS
Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com
POLYPROPYLENE
• Hydrophobic, high resistance to solvents
• Wide range of chemical compatibility to organic solvents
• Ideal for biological sample filtration
• Low protein binding
• Ideal for chromatography protein analysis and biological sample filtration
• Suitable for acids and bases and general HPLC analysis
Cat. No. Description Colour Pack
40-100026
40-100027
40-100023
40-100022
40-100021
40-100020
40-100025
40-100024
Polypropylene Syringe Filters, 0.22µm, 4mm Purple 100
Polypropylene Syringe Filters, 0.45µm, 4mm Purple 100
Polypropylene Syringe Filters, 0.22µm, 13mm Purple 100
Polypropylene Syringe Filters, 0.45µm, 13mm Purple 100
Polypropylene Syringe Filters, 0.22µm, 25mm Purple 100
Polypropylene Syringe Filters, 0.45µm, 25mm Purple 100
Polypropylene Syringe Filters, 0.22µm, 30mm Purple 100
Polypropylene Syringe Filters, 0.45µm, 30mm Purple 100
40-100023-S
40-100022-S
40-100021-S
40-100020-S
40-100025-S
40-100024-S
Polypropylene Syringe Filters, 0.22µm, 13mm, Sterile Purple 100
Polypropylene Syringe Filters, 0.45µm, 13mm, Sterile Purple 100
Polypropylene Syringe Filters, 0.22µm, 25mm, Sterile Purple 100
Polypropylene Syringe Filters, 0.45µm, 25mm, Sterile Purple 100
Polypropylene Syringe Filters, 0.22µm, 30mm, Sterile Purple 100
Polypropylene Syringe Filters, 0.45µm, 30mm, Sterile Purple 100
13
GREYHOUND Q-Fil SYRINGE FILTERSGREYHOUND Q-Fil SYRINGE FILTERS
POLYETHERSULFONE
• Hydrophilic membrane
• Very low protein and nucleotic acid binding
• Provides high flow rates and good throughput volume
• Best choice for tissue culture work
• Very low extractables
• Mechanically strong membrane, suitable for use with strong bases, alcohols
and resistive proteins
• Excellent flow rates
Cat. No. Description Colour Pack
40-100340
40-100341
40-100053
40-100052
40-100051
40-100050
40-100055
40-100054
40-100053-PF
40-100052-PF
40-100051-PF
40-100050-PF
40-100055-PF
40-100054-PF
40-100053-S
40-100052-S
40-100051-S
40-100050-S
40-100055-S
40-100054-S
Polyethersulfone Syringe Filters, 0.22µm, 4mm Clear 100
Polyethersulfone Syringe Filters, 0.45µm, 4mm Clear 100
Polyethersulfone Syringe Filters, 0.22µm, 13mm Dark Green 100
Polyethersulfone Syringe Filters, 0.45µm, 13mm Dark Green 100
Polyethersulfone Syringe Filters, 0.22µm, 25mm Dark Green 100
Polyethersulfone Syringe Filters, 0.45µm, 25mm Dark Green 100
Polyethersulfone Syringe Filters, 0.22µm, 30mm Dark Green 100
Polyethersulfone Syringe Filters, 0.45µm, 30mm Dark Green 100
Polyethersulfone Syringe Filters, 0.22µm, 13mm, with pre-filter Dark Green 100
Polyethersulfone Syringe Filters, 0.45µm, 13mm, with pre-filter Dark Green 100
Polyethersulfone Syringe Filters, 0.22µm, 25mm, with pre-filter Dark Green 100
Polyethersulfone Syringe Filters, 0.45µm, 25mm, with pre-filter Dark Green 100
Polyethersulfone Syringe Filters, 0.22µm, 30mm, with pre-filter Dark Green 100
Polyethersulfone Syringe Filters, 0.45µm, 30mm, with pre-filter Dark Green 100
Polyethersulfone Syringe Filters, 0.22µm, 13mm, Sterile Dark Green 100
Polyethersulfone Syringe Filters, 0.45µm, 13mm, Sterile Dark Green 100
Polyethersulfone Syringe Filters, 0.22µm, 25mm, Sterile Dark Green 100
Polyethersulfone Syringe Filters, 0.45µm, 25mm, Sterile Dark Green 100
Polyethersulfone Syringe Filters, 0.22µm, 30mm, Sterile Dark Green 100
Polyethersulfone Syringe Filters, 0.45µm, 30mm, Sterile Dark Green 100
Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com
14
GREYHOUND Q-Fil SYRINGE FILTERS
Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com
REGENERATED CELLULOSE
• Hydrophilic, solvent resistant
• Very low protein binding
• Compatible with most common HPLC solvents
• Compatible with aqueous samples in pH range 3 to 12
• Suitable for biological samples and important for protein recuperation
• Best choice for low non-specific binding applications, tissue culture media filtration
and biological sample filtration
Not suitable for use with strong acids, chloroform or THF
Cat. No. Description Colour Pack
40-100043
40-100042
40-100041
40-100040
40-100046
40-100045
Regenerated Cellulose Syringe Filters, 0.22µm, 13mm Light Blue 100
Regenerated Cellulose Syringe Filters, 0.45µm, 13mm Light Blue 100
Regenerated Cellulose Syringe Filters, 0.22µm, 25mm Light Blue 100
Regenerated Cellulose Syringe Filters, 0.45µm, 25mm Light Blue 100
Regenerated Cellulose Syringe Filters, 0.22µm, 30mm Light Blue 100
Regenerated Cellulose Syringe Filters, 0.45µm, 30mm Light Blue 100
40-100043-PF
40-100042-PF
40-100041-PF
40-100040-PF
40-100046-PF
40-100045-PF
Regenerated Cellulose Syringe Filters, 0.22µm, 13mm, with pre-filter Light Blue 100
Regenerated Cellulose Syringe Filters, 0.45µm, 13mm, with pre-filter Light Blue 100
Regenerated Cellulose Syringe Filters, 0.22µm, 25mm, with pre-filter Light Blue 100
Regenerated Cellulose Syringe Filters, 0.45µm, 25mm, with pre-filter Light Blue 100
Regenerated Cellulose Syringe Filters, 0.22µm, 30mm, with pre-filter Light Blue 100
Regenerated Cellulose Syringe Filters, 0.45µm, 30mm, with pre-filter Light Blue 100
40-100043-S
40-100042-S
40-100041-S
40-100040-S
40-100046-S
40-100045-S
Regenerated Cellulose Syringe Filters, 0.22µm, 13mm, Sterile Light Blue 100
Regenerated Cellulose Syringe Filters, 0.45µm, 13mm, Sterile Light Blue 100
Regenerated Cellulose Syringe Filters, 0.22µm, 25mm, Sterile Light Blue 100
Regenerated Cellulose Syringe Filters, 0.45µm, 25mm, Sterile Light Blue 100
Regenerated Cellulose Syringe Filters, 0.22µm, 30mm, Sterile Light Blue 100
Regenerated Cellulose Syringe Filters, 0.45µm, 30mm, Sterile Light Blue 100
15
GREYHOUND Q-Fil SYRINGE FILTERS
MIXED CELLULOSE ESTERS (MCE)
• A mixture of nitrocellulose and cellulose acetate
• Hydrophilic membrane
• Suitable for cleaning or sterilising many aqueous solutions
• Ideal for biological samples or culture media
Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com
Cat. No. Description Colour Pack
40-100073
40-100072
40-100071
40-100070
40-100075
40-100074
Mixed Cellulose Ester (MCE) Syringe Filters, 0.22µm, 13mm Light Green 100
Mixed Cellulose Ester (MCE) Syringe Filters, 0.45µm, 13mm Light Green 100
Mixed Cellulose Ester (MCE) Syringe Filters, 0.22µm, 25mm Light Green 100
Mixed Cellulose Ester (MCE) Syringe Filters, 0.45µm, 25mm Light Green 100
Mixed Cellulose Ester (MCE) Syringe Filters, 0.22µm, 30mm Light Green 100
Mixed Cellulose Ester (MCE) Syringe Filters, 0.45µm, 30mm Light Green 100
40-100073-PF
40-100072-PF
40-100071-PF
40-100070-PF
40-100075-PF
40-100074-PF
Mixed Cellulose Ester (MCE) Syringe Filters, 0.22µm, 13mm, with pre-filter Light Green 100
Mixed Cellulose Ester (MCE) Syringe Filters, 0.45µm, 13mm, with pre-filter Light Green 100
Mixed Cellulose Ester (MCE) Syringe Filters, 0.22µm, 25mm, with pre-filter Light Green 100
Mixed Cellulose Ester (MCE) Syringe Filters, 0.45µm, 25mm, with pre-filter Light Green 100
Mixed Cellulose Ester (MCE) Syringe Filters, 0.22µm, 30mm, with pre-filter Light Green 100
Mixed Cellulose Ester (MCE) Syringe Filters, 0.45µm, 30mm, with pre-filter Light Green 100
40-100073-S
40-100072-S
40-100071-S
40-100070-S
40-100075-S
40-100074-S
Mixed Cellulose Ester (MCE) Syringe Filters, 0.22µm, 13mm, Sterile Light Green 100
Mixed Cellulose Ester (MCE) Syringe Filters, 0.45µm, 13mm, Sterile Light Green 100
Mixed Cellulose Ester (MCE) Syringe Filters, 0.22µm, 25mm, Sterile Light Green 100
Mixed Cellulose Ester (MCE) Syringe Filters, 0.45µm, 25mm, Sterile Light Green 100
Mixed Cellulose Ester (MCE) Syringe Filters, 0.22µm, 30mm, Sterile Light Green 100
Mixed Cellulose Ester (MCE) Syringe Filters, 0.45µm, 30mm, Sterile Light Green 100
16
GREYHOUND Q-Fil SYRINGE FILTERS
GLASS MICROFIBER (GMF)
• Commonly used as pre-filters to remove large particulates and extend
the loading capacity of the filter membrane
• Ideal for dissolution tests
Cat. No. Description Colour Pack
40-100350
40-100351
40-100352
40-100353
40-100354
40-100355
40-100350-S
40-100351-S
40-100352-S
40-100353-S
40-100354-S
40-100355-S
Glass Fiber Syringe Filters, 0.7µm 13mm White 100
Glass Fiber Syringe Filters, 1.2µm 13mm White 100
Glass Fiber Syringe Filters, 0.7µm 25mm White 100
Glass Fiber Syringe Filters, 1.2µm 25mm White 100
Glass Fiber Syringe Filters, 0.7µm 30mm White 100
Glass Fiber Syringe Filters, 1.2µm 30mm White 100
Glass Fiber Syringe Filters, 0.7µm 13mm, Sterile White 100
Glass Fiber Syringe Filters, 1.2µm 13mm, Sterile White 100
Glass Fiber Syringe Filters, 0.7µm 25mm, Sterile White 100
Glass Fiber Syringe Filters, 1.2µm 25mm, Sterile White 100
Glass Fiber Syringe Filters, 0.7µm 30mm, Sterile White 100
Glass Fiber Syringe Filters, 1.2µm 30mm, Sterile White 100
6
GREYHOUND Q-Fil SYRINGE FILTERS
NYLON
• Hydrophilic membrane
• Excellent for HPLC samples and general filtration
• Compatible with organic and aqueous liquids
• Good solvent resistance and high protein retention
• Strong mechanical stability
Not suitable for use with strong acids or bases, halogenated hydrocarbons or protein
Cat. No. Description Colour Pack
40-100007
40-100008
40-100004
40-100003
40-100002
40-100001
40-100006
40-100005
Nylon Syringe Filters, 0.22µm, 4mm Clear 100
Nylon Syringe Filters, 0.45µm, 4mm Clear 100
Nylon Syringe Filters, 0.22µm, 13mm Blue 100
Nylon Syringe Filters, 0.45µm, 13mm Blue 100
Nylon Syringe Filters, 0.22µm, 25mm Blue 100
Nylon Syringe Filters, 0.45µm, 25mm Blue 100
Nylon Syringe Filters, 0.22µm, 30mm Blue 100
Nylon Syringe Filters, 0.45µm, 30mm Blue 100
40-100004-PF
40-100003-PF
40-100002-PF
40-100001-PF
40-100006-PF
40-100005-PF
Nylon Syringe Filters, 0.22µm, 13mm, with pre-filter Blue 100
Nylon Syringe Filters, 0.45µm, 13mm, with pre-filter Blue 100
Nylon Syringe Filters, 0.22µm, 25mm, with pre-filter Blue 100
Nylon Syringe Filters, 0.45µm, 25mm, with pre-filter Blue 100
Nylon Syringe Filters, 0.22µm, 30mm, with pre-filter Blue 100
Nylon Syringe Filters, 0.45µm, 30mm, with pre-filter Blue 100
40-100004-S
40-100003-S
40-100002-S
40-100001-S
40-100006-S
40-100005-S
Nylon Syringe Filters, 0.22µm, 13mm, Sterile Blue 100
Nylon Syringe Filters, 0.45µm, 13mm, Sterile Blue 100
Nylon Syringe Filters, 0.22µm, 25mm, Sterile Blue 100
Nylon Syringe Filters, 0.45µm, 25mm, Sterile Blue 100
Nylon Syringe Filters, 0.22µm, 30mm, Sterile Blue 100
Nylon Syringe Filters, 0.45µm, 30mm, Sterile Blue 100
Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com
Greyhound Chromatography
and Allied Chemicals
6 Kelvin Park, Birkenhead,
Merseyside CH41 1LT
United Kingdom
Tel: (+44)-0-151 649 4000
Fax: (+44)-0-151 649 4001
www.greyhoundchrom.com
Greyhound Q-Fil
Syringe Filters
© Copyright Greyhound Chromatography & Allied Chemicals 2020. All rights reserved.

More Related Content

PDF
Industrial training report by sandeep jana
PPT
Thin layer Chromatography and it's Techniques
PPTX
pelletization and pelletization technique
PPTX
Adsorption and partition column chromatography.pptx
PPTX
THIN LAYER CHROMATOGRAPHY
PPTX
Gel chromatography
PPT
Partition chromatography 3
PPTX
Gel Chromatography
Industrial training report by sandeep jana
Thin layer Chromatography and it's Techniques
pelletization and pelletization technique
Adsorption and partition column chromatography.pptx
THIN LAYER CHROMATOGRAPHY
Gel chromatography
Partition chromatography 3
Gel Chromatography

What's hot (20)

PPTX
Formulation & evaluation of Sustained release matrix tablet
PPTX
SPECTROFLUORIMETRY.pptx instrumentation, principle
PPT
PPTX
Affinity chromatography
PPTX
NRDC ppt by Rohit santosh nivdunge .pptx
PPTX
PPTX
Gel electrophoresis
PPTX
Spectrofluorimetry
PPTX
Tifac ppt
PDF
Alzet osmotic pumps
PPTX
PPTX
Study of Consolidation studies, Effect of Diffusion Parameters
PDF
Affinity Chromatography.pdf
PPT
Hplc instrumentation
PPTX
Absorption of drug
PPTX
UV visible Spectroscopy
PPTX
Electrophoresis and various techniques
PPTX
Diverter Valve.pptx
PPTX
High Performance Thin Layer Chromatography
Formulation & evaluation of Sustained release matrix tablet
SPECTROFLUORIMETRY.pptx instrumentation, principle
Affinity chromatography
NRDC ppt by Rohit santosh nivdunge .pptx
Gel electrophoresis
Spectrofluorimetry
Tifac ppt
Alzet osmotic pumps
Study of Consolidation studies, Effect of Diffusion Parameters
Affinity Chromatography.pdf
Hplc instrumentation
Absorption of drug
UV visible Spectroscopy
Electrophoresis and various techniques
Diverter Valve.pptx
High Performance Thin Layer Chromatography
Ad

Similar to Greyhound Chromatography Q - Fil Syringe Filters 2020 (20)

PDF
Greyhound Chromatography 'Q fil' Syringe Filters Catalogue
PDF
Microfiltration
PDF
Membrane selection guide
PPTX
HPTLC_An Introduction - Part 1 by Priyanka Singh
PPTX
High Performance Thin Layer Chromatography
PDF
Residential cartridge pdf document aqua middle east fzc
PDF
Residential cartridge
PDF
Residential cartridge pdf document aqua middle east fzc
PDF
Clarywound GF
PDF
Millipak® Final Fill Filters
PPTX
High Performance Liquid Chromatography (HPLC)
PPTX
PPTX
Instrumentation Of HPLC
PDF
Demalong Brochure
PPTX
HPTLC.pptx
PDF
Find your filter. What’s best for your process?
PDF
Find your filter. What’s best for your process?
PPT
HIGH PERFORMANCE THIN LAYER CHROMATOGRAPHY
Greyhound Chromatography 'Q fil' Syringe Filters Catalogue
Microfiltration
Membrane selection guide
HPTLC_An Introduction - Part 1 by Priyanka Singh
High Performance Thin Layer Chromatography
Residential cartridge pdf document aqua middle east fzc
Residential cartridge
Residential cartridge pdf document aqua middle east fzc
Clarywound GF
Millipak® Final Fill Filters
High Performance Liquid Chromatography (HPLC)
Instrumentation Of HPLC
Demalong Brochure
HPTLC.pptx
Find your filter. What’s best for your process?
Find your filter. What’s best for your process?
HIGH PERFORMANCE THIN LAYER CHROMATOGRAPHY
Ad

More from Greyhound Chromatography and Allied Chemicals (20)

PDF
PFAS TESTING SOLUTIONS FROM GREYHOUND CHROMATOGRAPHY
PDF
PFAS TESTING SOLUTIONS FROM GREYHOUND CHROMATOGRAPHY
PDF
Reference Standards Guide - Greyhound Chromatography.pdf
PDF
Is VAping all Smoke and Mirrors?
PDF
Chem Service Pesticide Reference Standards
PDF
PFAS Chromatography Products From Greyhound
PDF
Forever Chemicals The Hidden Threat from Toxic PFAS
PDF
Reference Standards for Testing Cannabis
PDF
Trajan Scientific Gas Purifiers
PDF
Greyhound Chromatography Q-Range HPLC Pump Spares
PDF
Greyhound Chromatography Q - Fil membrane Filters
PDF
Merlin Microseal For Gas Chromatography, A complete Guide
PDF
Q-Range Greyhound Chromatography Crimpers and Decappers
PDF
Wellington Laboratories Certified Reference Standards & Materials
PDF
Greyhound Chromatography HPLC Pumps
PDF
Greyhound Chromatography Q - Range Vials, Caps & Septa
PDF
PFAS TESTING SOLUTIONS FROM GREYHOUND CHROMATOGRAPHY
PFAS TESTING SOLUTIONS FROM GREYHOUND CHROMATOGRAPHY
Reference Standards Guide - Greyhound Chromatography.pdf
Is VAping all Smoke and Mirrors?
Chem Service Pesticide Reference Standards
PFAS Chromatography Products From Greyhound
Forever Chemicals The Hidden Threat from Toxic PFAS
Reference Standards for Testing Cannabis
Trajan Scientific Gas Purifiers
Greyhound Chromatography Q-Range HPLC Pump Spares
Greyhound Chromatography Q - Fil membrane Filters
Merlin Microseal For Gas Chromatography, A complete Guide
Q-Range Greyhound Chromatography Crimpers and Decappers
Wellington Laboratories Certified Reference Standards & Materials
Greyhound Chromatography HPLC Pumps
Greyhound Chromatography Q - Range Vials, Caps & Septa

Recently uploaded (20)

PPTX
02_OpenStax_Chemistry_Slides_20180406 copy.pptx
PPTX
bone as a tissue presentation micky.pptx
PDF
Worlds Next Door: A Candidate Giant Planet Imaged in the Habitable Zone of ↵ ...
PPT
Biochemestry- PPT ON Protein,Nitrogenous constituents of Urine, Blood, their ...
PDF
CuO Nps photocatalysts 15156456551564161
PDF
Metabolic Acidosis. pa,oakw,llwla,wwwwqw
PPTX
endocrine - management of adrenal incidentaloma.pptx
PDF
Social preventive and pharmacy. Pdf
PPTX
ELISA(Enzyme linked immunosorbent assay)
PDF
Sumer, Akkad and the mythology of the Toradja Sa'dan.pdf
PDF
2019UpdateAHAASAAISGuidelineSlideDeckrevisedADL12919.pdf
PPTX
Toxicity Studies in Drug Development Ensuring Safety, Efficacy, and Global Co...
PDF
The Future of Telehealth: Engineering New Platforms for Care (www.kiu.ac.ug)
PDF
Cosmology using numerical relativity - what hapenned before big bang?
PDF
Sujay Rao Mandavilli IJISRT25AUG764 context based approaches to population ma...
PDF
Chapter 3 - Human Development Poweroint presentation
PPTX
Presentation1 INTRODUCTION TO ENZYMES.pptx
PDF
Science Form five needed shit SCIENEce so
PPT
Animal tissues, epithelial, muscle, connective, nervous tissue
PPT
Enhancing Laboratory Quality Through ISO 15189 Compliance
02_OpenStax_Chemistry_Slides_20180406 copy.pptx
bone as a tissue presentation micky.pptx
Worlds Next Door: A Candidate Giant Planet Imaged in the Habitable Zone of ↵ ...
Biochemestry- PPT ON Protein,Nitrogenous constituents of Urine, Blood, their ...
CuO Nps photocatalysts 15156456551564161
Metabolic Acidosis. pa,oakw,llwla,wwwwqw
endocrine - management of adrenal incidentaloma.pptx
Social preventive and pharmacy. Pdf
ELISA(Enzyme linked immunosorbent assay)
Sumer, Akkad and the mythology of the Toradja Sa'dan.pdf
2019UpdateAHAASAAISGuidelineSlideDeckrevisedADL12919.pdf
Toxicity Studies in Drug Development Ensuring Safety, Efficacy, and Global Co...
The Future of Telehealth: Engineering New Platforms for Care (www.kiu.ac.ug)
Cosmology using numerical relativity - what hapenned before big bang?
Sujay Rao Mandavilli IJISRT25AUG764 context based approaches to population ma...
Chapter 3 - Human Development Poweroint presentation
Presentation1 INTRODUCTION TO ENZYMES.pptx
Science Form five needed shit SCIENEce so
Animal tissues, epithelial, muscle, connective, nervous tissue
Enhancing Laboratory Quality Through ISO 15189 Compliance

Greyhound Chromatography Q - Fil Syringe Filters 2020

  • 1. FilFil Simply Quality Greyhound Q-Fil Syringe Filters YOUR GLOBAL SCIENCE PARTNER
  • 2. RangeRange As a trusted name in the supply of chromatography consumables and certified reference standards, Greyhound also offers a comprehensive selection of top quality own brand Capillary columns and HPLC columns. This catalogue contains details of the Q-Fil range of Syringe Filters. Other product catalogues are available on request. These quality products are backed by the guaranteed reliability and technical support which has become synonymous with the name Greyhound. Visit our website at: www.greyhoundchrom.com for details of our full range of products. Welcome to a new era in analyte detection and column performance. Greyhound Your Global Science Partner Q-Fil Syringe Filters set the new Quality standard for today’s laboratory syringe filters. Manufactured from the highest quality medical grade, high density polypropylene. Q-Fil Syringe Filters provide excellent chemical compatibility with acids, alcohols, bases, ethers, glycols, ketones and oils. Every colour-coded filter is printed with details of the membrane material and its pore size on the outside of the filter and every box is labelled with the batch number making them ideal for traceability, GLPs and validation purposes. Greyhound Q-Fil Syringe Filters Q-Fil Syringe Filters Q-Cap Capillary Columns Q-Col HPLC Columns GC Septa and Ferrules FilFil SYRINGE FILTERS BY GREYHOUND Certificate of Conformance • Disposable Syringe Filters Greyhound Chromatography and Allied Chemicals 6 Kelvin Park Birkenhead Merseyside CH41 1LT England Tel: +44 (0) 151 649 4000 Fax: +44-(0) 151 649 4001 Email: [email protected] Web: www.greyhoundchrom.com This product complies with all Q-Fil Syringe Filter manufacturing specifications and was produced in accordance with ISO 9001 Quality Management System Product Q-Fil Syringe Filter Part Number 40-100001 Lot Number SM280616 Filter Material Hydrophilic Nylon 0.45µm Housing Material Polypropylene Membrane Diameter 25mm Test Specifications Visual Inspection Absence of External defects Luer Lock Female Luer-Lock Inlet, Male Slip Outlet Bubble Point 29 psi Burst Pressure 87 psi Filtration Area 4.08 cm3 Holdup Volume <100μL Volume Throughput 100mL Q-Fil Certificate of Conformance
  • 3. GREYHOUND Q-Fil SYRINGE FILTERS 1 Why filter your samples for HPLC? The main source of particle contamination in HPLC columns originate in the sample to be analysed. Therefore, the final preparation step prior to sample injection into the HPLC instrument is to remove any small particulates from the sample by filtration. Removal of the solid materials is very important as they can interfere with the compound of interest and easily clog up the column being used. This will inevitably have a detrimental effect on the performance of the column, i.e. back pressure, peak size, retention time, peak shape. Severe contamination can lead to the column being irreversibly blocked and therefore having to be replaced. Other costs can include instrument downtime, and the loss of valuable samples. Sample Types Samples differ in a variety of ways, they may be heavily loaded with fine or coarse particulates, dissolved in aqueous or organic solvents with varying viscosities. To facilitate the most appropriate sample preparation result, filters should be optimised to match the particular requirements of each kind of sample being injected. Standard Samples A matrix of 5-10mL is the most common sample volume, with low viscosity, low particle contamination and dissolved in either an organic or an aqueous solvent. Greyhound Q-Fil Regenerated Cellulose Syringe Filters are an excellent choice for such samples. Their inert housing manufactured from high density medical grade virgin polypropylene, complete with the integrated Regenerated Cellulose (RC) membrane has a high chemical resistance against the most common HPLC solvents and is very suitable for aqueous samples. Every batch is HPLC-tested for low extractables. Whilst 0.45µm is the most commonly used membrane porosity, the 0.22µm membrane provides improved purity when using capillary columns or HPLC packings with a particle size of 3µm or less Demanding Samples More difficult samples which contain high loads of particulates, high viscosity or unusually high volumes place additional challenges on the user when preparing samples for HPLC analysis. The particles have a tendency to block the filter, high viscosities will decrease the flow rate and high volumes increase the time required to complete the filtration process. These challenges often result in the user applying a greater degree of manual pressure to the process and potentially exceeding the maximum pressure limit of the filter with a subsequent risk of bursting the housing. As a result, the sample will be lost and a potential safety risk can arise if corrosive solvents or harmful chemicals are being filtered. To assist in overcoming these challenges, the use of Q-Fil Syringe Filters with a built in Glass Microfiber pre-filter are recommended. The pre-filter removes the larger particulates from the sample leaving only the smaller particulates to be filtered by the membrane. These filters increase the flow rate through the unit resulting in a higher volume of sample to be filtered and less pressure being required by the user. Small Volume Samples Smaller volume samples are often valuable and require special attention. Any loss of the analyte due to adsorption by the filter membrane or housing or a large dead volume can have a detrimental effect on the analysis. Smaller filters of 13mm and 4mm diameter decrease the dead volume to less than 25uL and 8uL respectively making them ideal for smaller volume samples. Summary Sample filtration is an important factor in ensuring that HPLC analysis is achieved in an efficient and cost effective way. The extensive range of Q-Fil Syringe Filters have been developed to meet the demands of the analyst and the different sample matrices being used and without losing any of the important sample. Why use Greyhound Q-Fil Syringe Filters? • Every batch of filters is manufactured and tested in accordance with strict ISO 9001:2015 quality procedures • Every individual Q-Fil Syringe Filter is visually inspected to ensure it meets our manufacturing and quality control specifications • Each batch of filters is tested prior to release for: - External Dimensions - Bubble Point - Water Flow Rate - UV Extractables - Burst Pressure and compliance - Filter Integrity About our Quality Control procedures • Every box is supplied with a Certificate of Conformance to guarantee its batch to batch quality and performance • The unique encapsulating process developed for these filters, forces the sample to pass only through the membrane, thus avoiding the possibility of leaks or contamination • Available in the most popular sizes, porosities and membrane types • Excellent resistance to all routinely used HPLC solvents • Filter housings are manufactured from the highest quality medical grade, high density polypropylene • Extremely low level of extractables for highly sensitive work • Luer connections fully comply with ISO 594-1
  • 4. GREYHOUND Q-Fil SYRINGE FILTERS 30mm Dia 25mm Dia 13mm Dia 4mm Dia 2 Designed for the largest sample volumes or solvent filtration Filtration area 5.39cm2 Maximum filtration volume <200ml Maximum operating pressure 87psi (6.0 bar) at 20°C Sample volume <200ml Holdup volume <200µl Designed for larger sample volumes or solvent filtration Filtration area 4.08cm2 Maximum filtration volume >100ml Maximum operating pressure 87psi (6.0 bar) at 20°C Sample volume <100ml Holdup volume <100µl Suitable for most applications Filtration area 1.09cm2 Maximum filtration volume >10ml Maximum operating pressure 87psi (6.0 bar) at 20°C Sample volume <10ml Holdup volume <25µl Suitable for smaller volume applications Filtration area 0.1cm2 Maximum filtration volume <2ml Maximum operating pressure 75psi (5.0 bar) at 20°C Sample volume <2ml Holdup volume <8ul • Choose the size of filter based on the volume of sample to be filtered • Choose the filters porosity based on the size of the potential particulates in the sample. It is important to be aware that the finer the porosity of the membrane the greater the pressure will be required to pass the sample through the filter. A sample containing large quantities of particulates is best filtered using a filter with a built-in glass microfiber pre-filter • Choose the type of membrane based on the solvent being filtered Selecting the right Q-Fil Syringe Filter
  • 5. GREYHOUND Q-Fil SYRINGE FILTERS 30mm Dia 25mm Dia 13mm Dia 4mm Dia 2 Designed for the largest sample volumes or solvent filtration Filtration area 5.39cm2 Maximum filtration volume <200ml Maximum operating pressure 87psi (6.0 bar) at 20°C Sample volume <200ml Holdup volume <200µl Designed for larger sample volumes or solvent filtration Filtration area 4.08cm2 Maximum filtration volume >100ml Maximum operating pressure 87psi (6.0 bar) at 20°C Sample volume <100ml Holdup volume <100µl Suitable for most applications Filtration area 1.09cm2 Maximum filtration volume >10ml Maximum operating pressure 87psi (6.0 bar) at 20°C Sample volume <10ml Holdup volume <25µl Suitable for smaller volume applications Filtration area 0.1cm2 Maximum filtration volume <2ml Maximum operating pressure 75psi (5.0 bar) at 20°C Sample volume <2ml Holdup volume <8ul • Choose the size of filter based on the volume of sample to be filtered • Choose the filters porosity based on the size of the potential particulates in the sample. It is important to be aware that the finer the porosity of the membrane the greater the pressure will be required to pass the sample through the filter. A sample containing large quantities of particulates is best filtered using a filter with a built-in glass microfiber pre-filter • Choose the type of membrane based on the solvent being filtered Selecting the right Q-Fil Syringe Filter
  • 6. 4 GREYHOUND Q-Fil SYRINGE FILTERS Syringe Filter Membrane Compatibility Chart Chemical Nylon PTFE PVDF PES CA RC PP GMF ACIDS Acetic, Glacial LC C C C IC C C C Acetic, 25% C C C C CA C C C Hydrochloric, Concentrated IC C C C IC IC C C Hydrochloric, 25% IC C C C IC IC C C Sulphuric, Concentrated IC C IC IC IC IC C C Sulphuric, 25% IC C C C IC LC C C Nitric, Concentrated IC C C IC IC IC C LC Nitric, 25% IC C C C IC IC C LC Phosphoric, 25% IC C ND ND CA LC C ND Formic, 25% IC C ND ND LC C C C Trichloroacetic, 10% IC C ND ND CA C C ND ALCOHOLS Methanol, 98% C C C C C C C C Ethanol, 98% C C C C C C C C Ethanol, 70% IC C C C C C C C Isopropanol C C C C C C C C n-Propanol C C C C C C C C Amyl Alcohol (Butanol) C C C C C C C C Benzyl Alcohol C C C ND LC C C IC Ethylene Glycol C C C C C C C C Propylene Glycol C C C C LC C C C Clycerol C C C C C C C C ALKALIS Ammonium Hydroxide, 25% C C LC C C LC C C Sodium Hydroxide, 3N C C C C IC LC C IC AMINES AND AMIDES Dimethyl Formamide LC C IC IC IC LC C C Diethylacetamide C C ND ND IC C ND C Triethanolamine C C ND ND C C ND ND Aniline ND C ND ND IC C ND ND Pyridine C C IC IC IC C IC C Acetonitrile C C C LC IC C C C ESTERS Ethyl Acetate/Methyl Acetate C C C IC IC C LC C Amyl Acetate/Butyl Acetate C C IC IC LC C LC C Propyl Acetate C C IC IC LC C LC ND Propylene Glycol Acetate ND C ND IC IC C C ND 2-Ethoxyethyl Acetate ND C ND IC LC C ND ND Methyl Cellusolve ND C ND IC IC C C C Use this information to determine the ability of a specific syringe filter membrane to withstand exposure to solvent. All concentrations are 100% unless noted.
  • 7. 5 GREYHOUND Q-Fil SYRINGE FILTERS Chemical Nylon PTFE PVDF PES CA RC PP GMF ESTERS Benzyl Benzoate C C ND IC C C ND ND Isopropyl Myristate C C ND IC C C ND ND Tricresyl Phosphate ND C ND IC C C ND ND HALOGENATED HYDROCARBONS Methylene Chloride LC C C IC IC C LC C Chloroform C C C IC IC C LC C Trichloroethylene C C C IC C C C C Chlorobenzene C C C IC C C C C Freon C C C IC C C C C Carbon Tetrachloride C C C IC LC C LC C HYDROCARBONS Hexane/Xylene C C C IC C C IC C Toluene/Benzene C C C IC C C IC C Kerosene/Gasoline C C C LC C C LC ND Tetralin/Decalin ND C C ND C C ND ND KETONES Acetone C C IC IC IC C C C Cyclohexanone C C IC IC IC C C C Methyl Ethyl Ketone C C IC IC LC C LC C Isopropylacetone C C IC IC C C ND C Methyl Isobutyl Ketone ND C IC IC ND C LC C ORGANIC OXIDES Ethyl Ether C C C C C C LC ND Dioxane C C LC IC I C C C Tetrahydrofuran C C LC IC I C C C Triethanolamine C C ND ND C C ND ND Dimethylsulfoxide (DMSO) C C IC IC I C C C Isopropyl Ether ND C C C C C C ND MISCELLANEOUS Phenol,Aqueous Solution 10% ND C LC IC IC IC C C Formaldehyde Aqueous C C C C C LC C C Solution 30% Hydrogen Peroxide 30% C C ND ND C C ND ND Silicone Oil/Mineral Oil ND C C C C C C C LEGEND PVDF Polyvinylidene PES Polyethersulfone CA Cellulose Acetate RC Regenerated Cellulose PP Polypropylene GMF Glass MicroFibre C Compatible LC Limited Compatibility (membrane may swell and shrink) IC Incompatible (not recommended) ND No compatibility data currently available PTFE Polytetrafluoroethylene (Teflon®)
  • 8. 6 GREYHOUND Q-Fil SYRINGE FILTERS NYLON • Hydrophilic membrane • Excellent for HPLC samples and general filtration • Compatible with organic and aqueous liquids • Good solvent resistance and high protein retention • Strong mechanical stability Not suitable for use with strong acids or bases, halogenated hydrocarbons or protein Cat. No. Description Colour Pack 40-100007 40-100008 40-100004 40-100003 40-100002 40-100001 40-100006 40-100005 Nylon Syringe Filters, 0.22µm, 4mm Clear 100 Nylon Syringe Filters, 0.45µm, 4mm Clear 100 Nylon Syringe Filters, 0.22µm, 13mm Blue 100 Nylon Syringe Filters, 0.45µm, 13mm Blue 100 Nylon Syringe Filters, 0.22µm, 25mm Blue 100 Nylon Syringe Filters, 0.45µm, 25mm Blue 100 Nylon Syringe Filters, 0.22µm, 30mm Blue 100 Nylon Syringe Filters, 0.45µm, 30mm Blue 100 40-100004-PF 40-100003-PF 40-100002-PF 40-100001-PF 40-100006-PF 40-100005-PF Nylon Syringe Filters, 0.22µm, 13mm, with pre-filter Blue 100 Nylon Syringe Filters, 0.45µm, 13mm, with pre-filter Blue 100 Nylon Syringe Filters, 0.22µm, 25mm, with pre-filter Blue 100 Nylon Syringe Filters, 0.45µm, 25mm, with pre-filter Blue 100 Nylon Syringe Filters, 0.22µm, 30mm, with pre-filter Blue 100 Nylon Syringe Filters, 0.45µm, 30mm, with pre-filter Blue 100 40-100004-S 40-100003-S 40-100002-S 40-100001-S 40-100006-S 40-100005-S Nylon Syringe Filters, 0.22µm, 13mm, Sterile Blue 100 Nylon Syringe Filters, 0.45µm, 13mm, Sterile Blue 100 Nylon Syringe Filters, 0.22µm, 25mm, Sterile Blue 100 Nylon Syringe Filters, 0.45µm, 25mm, Sterile Blue 100 Nylon Syringe Filters, 0.22µm, 30mm, Sterile Blue 100 Nylon Syringe Filters, 0.45µm, 30mm, Sterile Blue 100 Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com
  • 9. 7 GREYHOUND Q-Fil SYRINGE FILTERS Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com CELLULOSE ACETATE • Hydrophilic membrane • Ideal for aqueous based samples, tissue culture media filtration and sensitive biological samples • Very low protein binding membrane, lower than PVDF and PES membranes • Lower chemical resistance than Regenerated Cellulose Not suitable for use with organic solvents Cat. No. Description Colour Pack 40-100330 40-100331 40-100063 40-100062 40-100061 40-100060 40-100065 40-100064 Cellulose Acetate Syringe Filters, 0.22µm, 4mm Clear 100 Cellulose Acetate Syringe Filters, 0.45µm, 4mm Clear 100 Cellulose Acetate Syringe Filters, 0.22µm, 13mm Orange 100 Cellulose Acetate Syringe Filters, 0.45µm, 13mm Orange 100 Cellulose Acetate Syringe Filters, 0.22µm, 25mm Orange 100 Cellulose Acetate Syringe Filters, 0.45µm, 25mm Orange 100 Cellulose Acetate Syringe Filters, 0.22µm, 30mm Orange 100 Cellulose Acetate Syringe Filters, 0.45µm, 30mm Orange 100 40-100063-PF 40-100062-PF 40-100061-PF 40-100060-PF 40-100065-PF 40-100064-PF 40-100063-S 40-100062-S 40-100061-S 40-100060-S 40-100065-S 40-100064-S Cellulose Acetate Syringe Filters, 0.22µm, 13mm, with pre-filter Orange 100 Cellulose Acetate Syringe Filters, 0.45µm, 13mm, with pre-filter Orange 100 Cellulose Acetate Syringe Filters, 0.22µm, 25mm, with pre-filter Orange 100 Cellulose Acetate Syringe Filters, 0.45µm, 25mm, with pre-filter Orange 100 Cellulose Acetate Syringe Filters, 0.22µm, 30mm, with pre-filter Orange 100 Cellulose Acetate Syringe Filters, 0.45µm, 30mm, with pre-filter Orange 100 Cellulose Acetate Syringe Filters, 0.22µm, 13mm, Sterile Orange 100 Cellulose Acetate Syringe Filters, 0.45µm, 13mm, Sterile Orange 100 Cellulose Acetate Syringe Filters, 0.22µm, 25mm, Sterile Orange 100 Cellulose Acetate Syringe Filters, 0.45µm, 25mm, Sterile Orange 100 Cellulose Acetate Syringe Filters, 0.22µm, 30mm, Sterile Orange 100 Cellulose Acetate Syringe Filters, 0.45µm, 30mm, Sterile Orange 100
  • 10. 8 GREYHOUND Q-Fil SYRINGE FILTERS Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com PTFE (HYDROPHOBIC) • Hydrophobic membrane resistant to strong acids, aggressive solvents, alcohols, bases and aromatics • Ideal for the filtration and degassing of chromatography solvents and for extremely basic mobile phase solutions • Very low extractables • Mechanically strong • Excellent thermal stability Cat. No. Description Colour Pack 40-100300 40-100301 40-100017 40-100016 40-100015 40-100014 40-100019 40-100018 PTFE Hydrophobic Syringe Filters, 0.22µm, 4mm Clear 100 PTFE Hydrophobic Syringe Filters, 0.45µm, 4mm Clear 100 PTFE Hydrophobic Syringe Filters, 0.22µm, 13mm Red 100 PTFE Hydrophobic Syringe Filters, 0.45µm, 13mm Red 100 PTFE Hydrophobic Syringe Filters, 0.22µm, 25mm Red 100 PTFE Hydrophobic Syringe Filters, 0.45µm, 25mm Red 100 PTFE Hydrophobic Syringe Filters, 0.22µm, 30mm Red 100 PTFE Hydrophobic Syringe Filters, 0.45µm, 30mm Red 100 40-100017-PF 40-100016-PF 40-100015-PF 40-100014-PF 40-100019-PF 40-100018-PF PTFE Hydrophobic Syringe Filters, 0.22µm, 13mm, with pre-filter Red 100 PTFE Hydrophobic Syringe Filters, 0.45µm, 13mm, with pre-filter Red 100 PTFE Hydrophobic Syringe Filters, 0.22µm, 25mm, with pre-filter Red 100 PTFE Hydrophobic Syringe Filters, 0.45µm, 25mm, with pre-filter Red 100 PTFE Hydrophobic Syringe Filters, 0.22µm, 30mm, with pre-filter Red 100 PTFE Hydrophobic Syringe Filters, 0.45µm, 30mm, with pre-filter Red 100 40-100017-S 40-100016-S 40-100015-S 40-100014-S 40-100019-S 40-100018-S PTFE Hydrophobic Syringe Filters, 0.22µm, 13mm, Sterile Red 100 PTFE Hydrophobic Syringe Filters, 0.45µm, 13mm, Sterile Red 100 PTFE Hydrophobic Syringe Filters, 0.22µm, 25mm, Sterile Red 100 PTFE Hydrophobic Syringe Filters, 0.45µm, 25mm, Sterile Red 100 PTFE Hydrophobic Syringe Filters, 0.22µm, 30mm, Sterile Red 100 PTFE Hydrophobic Syringe Filters, 0.45µm, 30mm, Sterile Red 100
  • 11. PTFE (HYDROPHILIC) • Hydrophilic membrane compatible with aqueous, organic solvents, strong acids and alkalis • Mechanically strong • Excellent thermal stability • Low protein binding 9 GREYHOUND Q-Fil SYRINGE FILTERS Cat. No. Description Colour Pack 40-100310 40-100311 40-100312 40-100313 40-100314 40-100315 40-100316 40-100317 40-100312-PF 40-100313-PF 40-100314-PF 40-100315-PF 40-100316-PF 40-100317-PF 40-100312-S 40-100313-S 40-100314-S 40-100315-S 40-100316-S 40-100317-S PTFE Hydrophilic Syringe Filters, 0.22µm, 4mm Clear 100 PTFE Hydrophilic Syringe Filters, 0.45µm, 4mm Clear 100 PTFE Hydrophilic Syringe Filters, 0.22µm, 13mm Red 100 PTFE Hydrophilic Syringe Filters, 0.45µm, 13mm Red 100 PTFE Hydrophilic Syringe Filters, 0.22µm, 25mm Red 100 PTFE Hydrophilic Syringe Filters, 0.45µm, 25mm Red 100 PTFE Hydrophilic Syringe Filters, 0.22µm, 30mm Red 100 PTFE Hydrophilic Syringe Filters, 0.45µm, 30mm Red 100 PTFE Hydrophilic Syringe Filters, 0.22µm, 13mm, with pre-filter Red 100 PTFE Hydrophilic Syringe Filters, 0.45µm, 13mm, with pre-filter Red 100 PTFE Hydrophilic Syringe Filters, 0.22µm, 25mm, with pre-filter Red 100 PTFE Hydrophilic Syringe Filters, 0.45µm, 25mm, with pre-filter Red 100 PTFE Hydrophilic Syringe Filters, 0.22µm, 30mm, with pre-filter Red 100 PTFE Hydrophilic Syringe Filters, 0.45µm, 30mm, with pre-filter Red 100 PTFE Hydrophilic Syringe Filters, 0.22µm, 13mm, Sterile Red 100 PTFE Hydrophilic Syringe Filters, 0.45µm, 13mm, Sterile Red 100 PTFE Hydrophilic Syringe Filters, 0.22µm, 25mm, Sterile Red 100 PTFE Hydrophilic Syringe Filters, 0.45µm, 25mm, Sterile Red 100 PTFE Hydrophilic Syringe Filters, 0.22µm, 30mm, Sterile Red 100 PTFE Hydrophilic Syringe Filters, 0.45µm, 30mm, Sterile Red 100 Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com
  • 12. 10 GREYHOUND Q-Fil SYRINGE FILTERS Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com PVDF (HYDROPHOBIC) • Polyvinylidene difluoride membrane, hydrophobic • Resistant to solvents, exhibits low levels of extractables • Low protein binding membrane, can be used with proteins and peptides • Suitable for filtration of aqueous and organic solvents • Ideal for HPLC and general biological filtration Cat. No. Description Colour Pack 40-100360 40-100361 40-100362 40-100363 40-100364 40-100365 40-100366 40-100367 40-100362-PF 40-100363-PF 40-100364-PF 40-100365-PF 40-100366-PF 40-100367-PF 40-100362-S 40-100363-S 40-100364-S 40-100365-S 40-100366-S 40-100367-S PVDF Hydrophobic Syringe Filters, 0.22µm, 4mm Clear 100 PVDF Hydrophobic Syringe Filters, 0.45µm, 4mm Clear 100 PVDF Hydrophobic Syringe Filters, 0.22µm, 13mm Yellow 100 PVDF Hydrophobic Syringe Filters, 0.45µm, 13mm Yellow 100 PVDF Hydrophobic Syringe Filters, 0.22µm, 25mm Yellow 100 PVDF Hydrophobic Syringe Filters, 0.45µm, 25mm Yellow 100 PVDF Hydrophobic Syringe Filters, 0.22µm, 30mm Yellow 100 PVDF Hydrophobic Syringe Filters, 0.45µm, 30mm Yellow 100 PVDF Hydrophobic Syringe Filters, 0.22µm, 13mm, with pre-filter Yellow 100 PVDF Hydrophobic Syringe Filters, 0.45µm, 13mm, with pre-filter Yellow 100 PVDF Hydrophobic Syringe Filters, 0.22µm, 25mm, with pre-filter Yellow 100 PVDF Hydrophobic Syringe Filters, 0.45µm, 25mm, with pre-filter Yellow 100 PVDF Hydrophobic Syringe Filters, 0.22µm, 30mm, with pre-filter Yellow 100 PVDF Hydrophobic Syringe Filters, 0.45µm, 30mm, with pre-filter Yellow 100 PVDF Hydrophobic Syringe Filters, 0.22µm, 13mm, Sterile Yellow 100 PVDF Hydrophobic Syringe Filters, 0.45µm, 13mm, Sterile Yellow 100 PVDF Hydrophobic Syringe Filters, 0.22µm, 25mm, Sterile Yellow 100 PVDF Hydrophobic Syringe Filters, 0.45µm, 25mm, Sterile Yellow 100 PVDF Hydrophobic Syringe Filters, 0.22µm, 30mm, Sterile Yellow 100 PVDF Hydrophobic Syringe Filters, 0.45µm, 30mm, Sterile Yellow 100
  • 13. 11 GREYHOUND Q-Fil SYRINGE FILTERS Cat. No. Description Colour Pack 40-100320 40-100321 40-100033 40-100032 40-100031 40-100030 40-100035 40-100034 PVDF Hydrophilic Syringe Filters, 0.22µm, 4mm Clear 100 PVDF Hydrophilic Syringe Filters, 0.45µm, 4mm Clear 100 PVDF Hydrophilic Syringe Filters, 0.22µm, 13mm Yellow 100 PVDF Hydrophilic Syringe Filters, 0.45µm, 13mm Yellow 100 PVDF Hydrophilic Syringe Filters, 0.22µm, 25mm Yellow 100 PVDF Hydrophilic Syringe Filters, 0.45µm, 25mm Yellow 100 PVDF Hydrophilic Syringe Filters, 0.22µm, 30mm Yellow 100 PVDF Hydrophilic Syringe Filters, 0.45µm, 30mm Yellow 100 40-100033-PF 40-100032-PF 40-100031-PF 40-100030-PF 40-100035-PF 40-100034-PF 40-100033-S 40-100032-S 40-100031-S 40-100030-S 40-100035-S 40-100034-S PVDF Hydrophilic Syringe Filters, 0.22µm, 13mm, with pre-filter Yellow 100 PVDF Hydrophilic Syringe Filters, 0.45µm, 13mm, with pre-filter Yellow 100 PVDF Hydrophilic Syringe Filters, 0.22µm, 25mm, with pre-filter Yellow 100 PVDF Hydrophilic Syringe Filters, 0.45µm, 25mm, with pre-filter Yellow 100 PVDF Hydrophilic Syringe Filters, 0.22µm, 30mm, with pre-filter Yellow 100 PVDF Hydrophilic Syringe Filters, 0.45µm, 30mm, with pre-filter Yellow 100 PVDF Hydrophilic Syringe Filters, 0.22µm, 13mm, Sterile Yellow 100 PVDF Hydrophilic Syringe Filters, 0.45µm, 13mm, Sterile Yellow 100 PVDF Hydrophilic Syringe Filters, 0.22µm, 25mm, Sterile Yellow 100 PVDF Hydrophilic Syringe Filters, 0.45µm, 25mm, Sterile Yellow 100 PVDF Hydrophilic Syringe Filters, 0.22µm, 30mm, Sterile Yellow 100 PVDF Hydrophilic Syringe Filters, 0.45µm, 30mm, Sterile Yellow 100 Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com PVDF (HYDROPHILIC) • Modified Polyvinylidene difluoride membrane, hydrophilic • Resistant to solvents, acids and chemicals • Very low protein and preservative binding • Clarification and purification of aqueous and organic solvents, acids and bases • Filtration of antibiotics, diagnostics, serum, culture media and vaccines
  • 14. 12 GREYHOUND Q-Fil SYRINGE FILTERS Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com POLYPROPYLENE • Hydrophobic, high resistance to solvents • Wide range of chemical compatibility to organic solvents • Ideal for biological sample filtration • Low protein binding • Ideal for chromatography protein analysis and biological sample filtration • Suitable for acids and bases and general HPLC analysis Cat. No. Description Colour Pack 40-100026 40-100027 40-100023 40-100022 40-100021 40-100020 40-100025 40-100024 Polypropylene Syringe Filters, 0.22µm, 4mm Purple 100 Polypropylene Syringe Filters, 0.45µm, 4mm Purple 100 Polypropylene Syringe Filters, 0.22µm, 13mm Purple 100 Polypropylene Syringe Filters, 0.45µm, 13mm Purple 100 Polypropylene Syringe Filters, 0.22µm, 25mm Purple 100 Polypropylene Syringe Filters, 0.45µm, 25mm Purple 100 Polypropylene Syringe Filters, 0.22µm, 30mm Purple 100 Polypropylene Syringe Filters, 0.45µm, 30mm Purple 100 40-100023-S 40-100022-S 40-100021-S 40-100020-S 40-100025-S 40-100024-S Polypropylene Syringe Filters, 0.22µm, 13mm, Sterile Purple 100 Polypropylene Syringe Filters, 0.45µm, 13mm, Sterile Purple 100 Polypropylene Syringe Filters, 0.22µm, 25mm, Sterile Purple 100 Polypropylene Syringe Filters, 0.45µm, 25mm, Sterile Purple 100 Polypropylene Syringe Filters, 0.22µm, 30mm, Sterile Purple 100 Polypropylene Syringe Filters, 0.45µm, 30mm, Sterile Purple 100
  • 15. 13 GREYHOUND Q-Fil SYRINGE FILTERSGREYHOUND Q-Fil SYRINGE FILTERS POLYETHERSULFONE • Hydrophilic membrane • Very low protein and nucleotic acid binding • Provides high flow rates and good throughput volume • Best choice for tissue culture work • Very low extractables • Mechanically strong membrane, suitable for use with strong bases, alcohols and resistive proteins • Excellent flow rates Cat. No. Description Colour Pack 40-100340 40-100341 40-100053 40-100052 40-100051 40-100050 40-100055 40-100054 40-100053-PF 40-100052-PF 40-100051-PF 40-100050-PF 40-100055-PF 40-100054-PF 40-100053-S 40-100052-S 40-100051-S 40-100050-S 40-100055-S 40-100054-S Polyethersulfone Syringe Filters, 0.22µm, 4mm Clear 100 Polyethersulfone Syringe Filters, 0.45µm, 4mm Clear 100 Polyethersulfone Syringe Filters, 0.22µm, 13mm Dark Green 100 Polyethersulfone Syringe Filters, 0.45µm, 13mm Dark Green 100 Polyethersulfone Syringe Filters, 0.22µm, 25mm Dark Green 100 Polyethersulfone Syringe Filters, 0.45µm, 25mm Dark Green 100 Polyethersulfone Syringe Filters, 0.22µm, 30mm Dark Green 100 Polyethersulfone Syringe Filters, 0.45µm, 30mm Dark Green 100 Polyethersulfone Syringe Filters, 0.22µm, 13mm, with pre-filter Dark Green 100 Polyethersulfone Syringe Filters, 0.45µm, 13mm, with pre-filter Dark Green 100 Polyethersulfone Syringe Filters, 0.22µm, 25mm, with pre-filter Dark Green 100 Polyethersulfone Syringe Filters, 0.45µm, 25mm, with pre-filter Dark Green 100 Polyethersulfone Syringe Filters, 0.22µm, 30mm, with pre-filter Dark Green 100 Polyethersulfone Syringe Filters, 0.45µm, 30mm, with pre-filter Dark Green 100 Polyethersulfone Syringe Filters, 0.22µm, 13mm, Sterile Dark Green 100 Polyethersulfone Syringe Filters, 0.45µm, 13mm, Sterile Dark Green 100 Polyethersulfone Syringe Filters, 0.22µm, 25mm, Sterile Dark Green 100 Polyethersulfone Syringe Filters, 0.45µm, 25mm, Sterile Dark Green 100 Polyethersulfone Syringe Filters, 0.22µm, 30mm, Sterile Dark Green 100 Polyethersulfone Syringe Filters, 0.45µm, 30mm, Sterile Dark Green 100 Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com
  • 16. 14 GREYHOUND Q-Fil SYRINGE FILTERS Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com REGENERATED CELLULOSE • Hydrophilic, solvent resistant • Very low protein binding • Compatible with most common HPLC solvents • Compatible with aqueous samples in pH range 3 to 12 • Suitable for biological samples and important for protein recuperation • Best choice for low non-specific binding applications, tissue culture media filtration and biological sample filtration Not suitable for use with strong acids, chloroform or THF Cat. No. Description Colour Pack 40-100043 40-100042 40-100041 40-100040 40-100046 40-100045 Regenerated Cellulose Syringe Filters, 0.22µm, 13mm Light Blue 100 Regenerated Cellulose Syringe Filters, 0.45µm, 13mm Light Blue 100 Regenerated Cellulose Syringe Filters, 0.22µm, 25mm Light Blue 100 Regenerated Cellulose Syringe Filters, 0.45µm, 25mm Light Blue 100 Regenerated Cellulose Syringe Filters, 0.22µm, 30mm Light Blue 100 Regenerated Cellulose Syringe Filters, 0.45µm, 30mm Light Blue 100 40-100043-PF 40-100042-PF 40-100041-PF 40-100040-PF 40-100046-PF 40-100045-PF Regenerated Cellulose Syringe Filters, 0.22µm, 13mm, with pre-filter Light Blue 100 Regenerated Cellulose Syringe Filters, 0.45µm, 13mm, with pre-filter Light Blue 100 Regenerated Cellulose Syringe Filters, 0.22µm, 25mm, with pre-filter Light Blue 100 Regenerated Cellulose Syringe Filters, 0.45µm, 25mm, with pre-filter Light Blue 100 Regenerated Cellulose Syringe Filters, 0.22µm, 30mm, with pre-filter Light Blue 100 Regenerated Cellulose Syringe Filters, 0.45µm, 30mm, with pre-filter Light Blue 100 40-100043-S 40-100042-S 40-100041-S 40-100040-S 40-100046-S 40-100045-S Regenerated Cellulose Syringe Filters, 0.22µm, 13mm, Sterile Light Blue 100 Regenerated Cellulose Syringe Filters, 0.45µm, 13mm, Sterile Light Blue 100 Regenerated Cellulose Syringe Filters, 0.22µm, 25mm, Sterile Light Blue 100 Regenerated Cellulose Syringe Filters, 0.45µm, 25mm, Sterile Light Blue 100 Regenerated Cellulose Syringe Filters, 0.22µm, 30mm, Sterile Light Blue 100 Regenerated Cellulose Syringe Filters, 0.45µm, 30mm, Sterile Light Blue 100
  • 17. 15 GREYHOUND Q-Fil SYRINGE FILTERS MIXED CELLULOSE ESTERS (MCE) • A mixture of nitrocellulose and cellulose acetate • Hydrophilic membrane • Suitable for cleaning or sterilising many aqueous solutions • Ideal for biological samples or culture media Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com Cat. No. Description Colour Pack 40-100073 40-100072 40-100071 40-100070 40-100075 40-100074 Mixed Cellulose Ester (MCE) Syringe Filters, 0.22µm, 13mm Light Green 100 Mixed Cellulose Ester (MCE) Syringe Filters, 0.45µm, 13mm Light Green 100 Mixed Cellulose Ester (MCE) Syringe Filters, 0.22µm, 25mm Light Green 100 Mixed Cellulose Ester (MCE) Syringe Filters, 0.45µm, 25mm Light Green 100 Mixed Cellulose Ester (MCE) Syringe Filters, 0.22µm, 30mm Light Green 100 Mixed Cellulose Ester (MCE) Syringe Filters, 0.45µm, 30mm Light Green 100 40-100073-PF 40-100072-PF 40-100071-PF 40-100070-PF 40-100075-PF 40-100074-PF Mixed Cellulose Ester (MCE) Syringe Filters, 0.22µm, 13mm, with pre-filter Light Green 100 Mixed Cellulose Ester (MCE) Syringe Filters, 0.45µm, 13mm, with pre-filter Light Green 100 Mixed Cellulose Ester (MCE) Syringe Filters, 0.22µm, 25mm, with pre-filter Light Green 100 Mixed Cellulose Ester (MCE) Syringe Filters, 0.45µm, 25mm, with pre-filter Light Green 100 Mixed Cellulose Ester (MCE) Syringe Filters, 0.22µm, 30mm, with pre-filter Light Green 100 Mixed Cellulose Ester (MCE) Syringe Filters, 0.45µm, 30mm, with pre-filter Light Green 100 40-100073-S 40-100072-S 40-100071-S 40-100070-S 40-100075-S 40-100074-S Mixed Cellulose Ester (MCE) Syringe Filters, 0.22µm, 13mm, Sterile Light Green 100 Mixed Cellulose Ester (MCE) Syringe Filters, 0.45µm, 13mm, Sterile Light Green 100 Mixed Cellulose Ester (MCE) Syringe Filters, 0.22µm, 25mm, Sterile Light Green 100 Mixed Cellulose Ester (MCE) Syringe Filters, 0.45µm, 25mm, Sterile Light Green 100 Mixed Cellulose Ester (MCE) Syringe Filters, 0.22µm, 30mm, Sterile Light Green 100 Mixed Cellulose Ester (MCE) Syringe Filters, 0.45µm, 30mm, Sterile Light Green 100
  • 18. 16 GREYHOUND Q-Fil SYRINGE FILTERS GLASS MICROFIBER (GMF) • Commonly used as pre-filters to remove large particulates and extend the loading capacity of the filter membrane • Ideal for dissolution tests Cat. No. Description Colour Pack 40-100350 40-100351 40-100352 40-100353 40-100354 40-100355 40-100350-S 40-100351-S 40-100352-S 40-100353-S 40-100354-S 40-100355-S Glass Fiber Syringe Filters, 0.7µm 13mm White 100 Glass Fiber Syringe Filters, 1.2µm 13mm White 100 Glass Fiber Syringe Filters, 0.7µm 25mm White 100 Glass Fiber Syringe Filters, 1.2µm 25mm White 100 Glass Fiber Syringe Filters, 0.7µm 30mm White 100 Glass Fiber Syringe Filters, 1.2µm 30mm White 100 Glass Fiber Syringe Filters, 0.7µm 13mm, Sterile White 100 Glass Fiber Syringe Filters, 1.2µm 13mm, Sterile White 100 Glass Fiber Syringe Filters, 0.7µm 25mm, Sterile White 100 Glass Fiber Syringe Filters, 1.2µm 25mm, Sterile White 100 Glass Fiber Syringe Filters, 0.7µm 30mm, Sterile White 100 Glass Fiber Syringe Filters, 1.2µm 30mm, Sterile White 100
  • 19. 6 GREYHOUND Q-Fil SYRINGE FILTERS NYLON • Hydrophilic membrane • Excellent for HPLC samples and general filtration • Compatible with organic and aqueous liquids • Good solvent resistance and high protein retention • Strong mechanical stability Not suitable for use with strong acids or bases, halogenated hydrocarbons or protein Cat. No. Description Colour Pack 40-100007 40-100008 40-100004 40-100003 40-100002 40-100001 40-100006 40-100005 Nylon Syringe Filters, 0.22µm, 4mm Clear 100 Nylon Syringe Filters, 0.45µm, 4mm Clear 100 Nylon Syringe Filters, 0.22µm, 13mm Blue 100 Nylon Syringe Filters, 0.45µm, 13mm Blue 100 Nylon Syringe Filters, 0.22µm, 25mm Blue 100 Nylon Syringe Filters, 0.45µm, 25mm Blue 100 Nylon Syringe Filters, 0.22µm, 30mm Blue 100 Nylon Syringe Filters, 0.45µm, 30mm Blue 100 40-100004-PF 40-100003-PF 40-100002-PF 40-100001-PF 40-100006-PF 40-100005-PF Nylon Syringe Filters, 0.22µm, 13mm, with pre-filter Blue 100 Nylon Syringe Filters, 0.45µm, 13mm, with pre-filter Blue 100 Nylon Syringe Filters, 0.22µm, 25mm, with pre-filter Blue 100 Nylon Syringe Filters, 0.45µm, 25mm, with pre-filter Blue 100 Nylon Syringe Filters, 0.22µm, 30mm, with pre-filter Blue 100 Nylon Syringe Filters, 0.45µm, 30mm, with pre-filter Blue 100 40-100004-S 40-100003-S 40-100002-S 40-100001-S 40-100006-S 40-100005-S Nylon Syringe Filters, 0.22µm, 13mm, Sterile Blue 100 Nylon Syringe Filters, 0.45µm, 13mm, Sterile Blue 100 Nylon Syringe Filters, 0.22µm, 25mm, Sterile Blue 100 Nylon Syringe Filters, 0.45µm, 25mm, Sterile Blue 100 Nylon Syringe Filters, 0.22µm, 30mm, Sterile Blue 100 Nylon Syringe Filters, 0.45µm, 30mm, Sterile Blue 100 Tel: +44(0)151 649 4000 • Fax: +44(0)151 649 4001 • www.greyhoundchrom.com
  • 20. Greyhound Chromatography and Allied Chemicals 6 Kelvin Park, Birkenhead, Merseyside CH41 1LT United Kingdom Tel: (+44)-0-151 649 4000 Fax: (+44)-0-151 649 4001 www.greyhoundchrom.com Greyhound Q-Fil Syringe Filters © Copyright Greyhound Chromatography & Allied Chemicals 2020. All rights reserved.