Pulmonary artery catheter for cardiac pressure monitoring
and its role in anesthetic practice
Dr. Shalini Saini
University College of Medical Sciences & GTB
Hospital, Delhi
Pulmonary artery catheter
• Introduction
• Insertion technique
• Indications
• Complications
• Abnormal pulmonary artery and wedge pressure
waveform
Introduction
• In 1970, Swan,Ganz and colleague introduced pulmonary artery catheter
Pulmonary artery catheter
• Standard : 7-9 Fr circumference
• 110cm length at 10cm intervals
• Four internal lumen-
1. Distal-pulmonary artery
pressure monitoring
2. Proximal-30cm for CVP
monitoring
3. It leads to balloon near the tip
4. It houses wires for a
temperature thermistor
Uses of pulmonary artery catheter
• Assessment of volume status in patients undergoing major
surgeries
• Cardiac output measurement by thermodilution technique
• Various hemodynamic parameters-pulmonary artery
pressure, pulmonary capillary wedge presssure,CVP,systemic
vascular resistance, pulmonary vascular resistance.
• Respiratory or oxygen transport measurement-mixed venous
oximetry.
Insertion
Sites of insertion
• Right internal jugular vein (preferred)
• Left internal jugular vein (2nd choice)
• Subclavian vein (disadvantages)
• External jugular vein ( superficial location but tortous)
• Antecubital vein
• Femoral vein
*After successful venous cannulation, there might be difficulty in
advancement of the catheter due to abnormal venous anatomy.
- most common: persistence of left superior vena cava.
RA RV PA
IJV-right 20cm 30cm 45cm
left 25cm 35cm 50cm
Antecubital –rt 50cm 65cm 80cm
-lt 55cm 70cm 85cm
Femoral v 40cm 50cm 65cm
Subclavian v 10cm 25cm 40cm
Distances to right atrium, right ventricle and pulmonary artery
Pressure Average (mm Hg) Range (mm Hg)
Right Atrium
a wave 6 2-7
v wave 5 2-7
Mean 3 1-5
Right Ventricle
Peak systolic 25 15-30
End-diastolic 6 1-7
Pulmonary Artery
Peak systolic 25 15-30
End-diastolic 9 4-12
Mean 15 9-19
Pulmonary Artery Wedge
Mean 9 4-12
Left Atrium
Mean 8 2-12
Left Ventricle
Peak systolic 130 90-140
End-diastolic 8 5-12
Normal Cardiovascular Pressures
Wave form recorded during passage of pulmonary artery catheter
• Right atrial pressure resembles central venous pressure waveform
• Right ventricular pressure shows higher systolic pressure
• Pulmonary artery pressure shows diastolic step up
• Pulmonary artery wedge pressure similar morphology as right atrial pressure but a,c
v waves appear later
Temporal relationships between systemic arterial
pressure,pulmonary artery pressure, central venous pressure and
pulmonary artery wedge pressure
-PAP upstroke precedes radial artery pressure upstroke
-Wedge pressure a wave follows ECG R wave
Three-zone model of pulmonary vasculature
-described by West and
colleague
-tip of PAC should lie in
zone3
-supine position favours
zone3 condition
Correlations of RAP to LVEDV
Indications
1. Patients undergoing cardiac surgery with
• Poor left ventricular compliance(ejection fration <0.4, LVEDP>18mm hg)
• Left wall motion abnormality
• Recent MI (<6 Months)
• Left main coronary lesion
• Valvular lesion
• Presence of pulmonary artery hypertension
2. Major procedures involving large fluid shifts or blood loss
in patients with-
• Cardiogenic or septic shock or with multiple organ failure
• Hemodynamic instability requiring ionotropes or intra-aortic
balloon counterpulsation
• Hepatic transplantation
• Massive ascites requiring major surgery
• Surgery of aorta requiring cross-clamping
• Large abdomino-perineal resection etc.
3. Intensive care unit
• To measure pulmonary artery and pulmonary capillary wedge
pressure
• To measure cardiac output by thermodilution
• To obtain intracavitary electrocardiogram
• To perform atrial or ventricular pacing
• To allow infusion of drugs
• To perform angiography
• To detect venous air embolism
4. Continous mixed venous oximetry
- To assess the adequacy of perfusion
Recommendations for perioperative use of PACs
(AHA 2007 guidelines)
• Class 2b-(level of evidence:B)
Use of PAC is reasonable in patients at risk for major hemodynamic
disturbances easily detected by PAC. However, decision must be based
on three parameters-
a. disease
b. surgical procedure
c. practice setting (Experience & interpretation)
• Class 3-(level of evidence:A)
Routine use of PAC perioperatively, especially low risk of hemodynamic
disturbances, is not recommended.
Pulmonary Artery Catheterisation and outcome
controversies
• PAC use in 5735 patients in first 24 hrs intensive care associated with
increased mortality, hospital stay and cost.(Connors etal,1997)
• Three trials including 3468 patients showed no effect on mortality but
higher incidence of adverse effects(Harvey etal,2005; The ESCAPE
Trial,2005; Sandham etal,2003)
• A review of 53312 patients from National Trauma Data Bank showed
-No mortality benefit in patients treated with PAC
-Injury scale greater: mortality decreased(Friese etal,2006)
• In mixed medical and surgical population,APACHE scores
<25 -increased mortality
>31 -significant benefit (Chittock etal,2004)
• A group of experienced cardiac anesthesiologists and surgeons
blinded to information from pulmonary artery catheterisation
during CABG surgery were unaware of 65% of severe
hemodynamic abnormalities.(Waller and Kaplan)
• ICU physicians were unable to accurately predict hemodynamic
data on clinical grounds and 60% made at least one change
in therapy and 33% changed their diagnosis based on PAC
data.(Iberti and Fisher)
Contraindications (Kaplan)
Absolute contraindications
• Tricuspid or pulmonary stenosis
• Right atrial or ventricular mass
• Tetralogy of Fallot
Relative contraindications
• Severe arrhythmias
• Coagulopathy
• Newly inserted pacemaker wires
Complications
1. Catheterisation
a. Arrythmia-primary complication
-most common premature ventricular contractions
-ventricular fibrillation
b. Right bundle branch block
c. Complete heart block
Treatment- balloon deflated and catheter withdrawn to right
atrium
2. Catheter residence
a. Catheter knotting -suspected when difficulty in withdrawing
-diagnosed with chest x-ray
-untied by radiologist
b.Thromboembolism –rising incidence
-increased with antifibrinolytic drugs
c. Pulmonary infarction
d. Infection ,endocarditis
e. Endocardial damage, cardiac valve injury
f. Thrombocytopenia (heparin induced)
g. Pulmonary artery rupture
-Incidence: 0.064%-0.20%
-Increased risk: female sex, hypothermia, anticoagulation,
advanced age, pulmonary hypertension, mitral stenosis,
coagulopathy, distal placement catheter, balloon hyperinflation
-Hallmark:hemoptysis and exsanguination
-Treatment:
1. Resuscitation-adequate oxygenation and ventilation
2. If hemorrhage minimal,with coagulopathy-correct coagulopathy
3. Protection of uninvolved lung by-tilting patient to affected side,
placement of double lumen endotracheal tube
4. Stop hemorrhage- apply PEEP, Bronchial blockers, resection.
5. Severe hemorrhage with recurrent bleeding-transcatheter coil
embolisation.
Abnormal pressure waveforms
A. Artifact
Overwedging occurs
when balloon
overinflated/distal
migration of
cathter/eccentric balloon
inflation.
B.Pathophysiologic changes
1.Mitral regurgitation
-Tall v waves in waveform
with bifid appearance
-PAP upstroke steeper
-Wedge pressure prominent v
wave with gradual upstroke
-Wedge pressure overestimates
left ventricular filling pressure
-Tall v wave:hypervolemia,CHF,
VSD.
2.Mitral stenosis
-Mean wedge pressure
increased
-y descent slurred due to
obstruction to bloood flow
-Similar abnormalities-left
atrial myxoma, left ventricle
infarction, pericardial
constriction,aortic stenosis,
systemic hypertension
3.Pericardial constriction
-prominent a and v waves
-steep x and y descent
-M or W configuration in CVP trace
-diastolic ‘dip and plateau’ pattern or
square root sign due to early diastolic
ventricular filling
-mid diastolic h wave (plateau) due to
interruption in flow due to restrictive
shell
4.Myocardial ischemia
• First time used in patient with
acute MI.
• PAP normal relatively
• PAWP slightly elevated
• PAWP morphology abnormal
-Tall a waves due to diastolic
dysfunction
Condition Site of Discrepancy Cause of Discrepancy
Positive end-expiratory pressure Mean PAWP > mean LAP
Creation of lung zone 1
or 2 or pericardial
pressure changes
Pulmonary arterial hypertension PADP > mean PAWP
Increased pulmonary
vascular resistance
Pulmonary veno-occlusive disease Mean PAWP > mean LAP
Obstruction to flow in
large pulmonary veins
Mitral stenosis Mean LAP > LVEDP
Obstruction to flow
across the mitral valve
Mitral regurgitation Mean LAP > LVEDP
Retrograde systolic v
wave raises mean atrial
pressure
Ventricular septal defect Mean LAP > LVEDP
Antegrade systolic v
wave raises mean atrial
pressure
Tachycardia PADP > mean LAP > LVEDP
Short diastole creates
pulmonary vascular and
mitral valve gradients
Overestimation of Left Ventricular End-Diastolic Pressure
Condition Site of Discrepacy Cause of Discrepancy
Diastolic dysfunction Mean LAP < LVEDP Increased end-diastolic a wave
Aortic regurgitation LAP a wave < LVEDP
Mitral valve closure before
end-diastole
Pulmonic regurgitation PADP < LVEDP
Bidirectional runoff for
pulmonary artery flow
Right bundle branch block PADP < LVEDP
Delayed pulmonic valve
opening
After pneumonectomy PAWP < LAP or LVEDP
Obstruction of pulmonary
blood flow
Underestimation of Left Ventricular End-Diastolic Pressure
Additional uses of pulmonary artery catheter
1. Thermodilution cardiac output monitoring
• Principle: Stewart-Hamilton equation
Q = V(Tb-Ti)K1.K2
Tb(t)dt
Q = Cardiac output
V = Injectate volume
Tb = Blood temperature
Ti = Injectate temperature
K1 = Density factor: (sp heat)(sp gravity)injectate
(sp heat)(sp gravity)blood
K2 = A computation constant which includes heat change in
transit,dead space of the catheter,injection rate, adjusts units to l/min
Tb(t)dt = change in blood temperature as a function of time
2. Mixed venous oximetry
Svo2 = Sao2- Vo2 / Q×1.36×Hb
Svo2 = mixed venous hemoglobin saturation(%)
Sao2 = arterial hemoglobin saturation(%)
Vo2 = oxygen consumption(ml/min)
Q = Cardiac output (l/min)
Hb = hemoglobin concentration(g/dl)
* Mixed venous hemoglobin saturation determined by sampling
from PAC either intermittently or continous
3. Right Ventricular Ejection Fraction
RVEDV = SV/RVEF
RVEDV = Right ventricular end diastolic volume (ml)
SV = Stroke volume
RVEF = Right ventricular ejection fraction
4. Derived Hemodynamic Variables
SVR = MAP-CVP × 80
CO
PVR = MPAP-PAWP×80
CO
SVR = systemic vascular resistance
PVR = pulmonary vascular resistance
MAP = mean arterial pressure
CVP = central venous pressure
MPAP = mean pulmonary artery pressure
PAWP = pulmonary artery wedge pressure
CO = cardiac output
References
• Ronald.D.Miller: Pulmonary artery catheter monitoring.
Cardiovascular monitoring 7th ed:1297-1314.
• Kaplan: Anesthesia techniques for cardiac surgical
procedures;399-408.
• Circulation. 2007;116:e418-e500
• Blitt: Monitoring. Pulmonary artery cathterisation;221-263.
Thank you

More Related Content

PPTX
Anaesthesia for cardiopulmonary bypass surgery [autosaved]
PPTX
Cardiovascular monitoring Part I
PPTX
Monitoring in cardiac ananesthesia
PPTX
INTRA-ARTERIAL BLOOD PRESSURE MONITORING
PPTX
Haemodynamic monitoring during cpb
PPTX
WEANING FROM CPB.pptx
PPTX
Pa catheter ctvac
Anaesthesia for cardiopulmonary bypass surgery [autosaved]
Cardiovascular monitoring Part I
Monitoring in cardiac ananesthesia
INTRA-ARTERIAL BLOOD PRESSURE MONITORING
Haemodynamic monitoring during cpb
WEANING FROM CPB.pptx
Pa catheter ctvac

What's hot (20)

PPTX
ARTERIAL CANNULATION.pptx
PPT
INTRA AORTIC BALLON PUMP (IABP)
PPTX
Anticoagulation and haemostasis during cardiopulmonary bypass
PPTX
Cardiomyopathy and anesthetic concern
PPSX
Transesophageal echocardiography
PDF
Fluid responsiveness in critically ill patients
PDF
Invasive blood pressure_monitoring
PPTX
Pericardiocentesis
PPTX
DHCA
PPT
Cardiac output monitoring
PPT
Pulmonary artery catherisation
PPTX
BMV,PTMC,BALLOON MITRAL VALVOTOMY, BAL, VIRBHAN BALAI, DR VIRBHAN
PPTX
Pulmonary artery catheter
PPTX
ALPHA STAT & PH STAT.pptx
PPTX
Double lumen tubes
PPTX
PPTX
cardiac output pptx
PPT
Airway adjuncts and management in ACLS
PPTX
Anaesthesia for cardiopulmonary bypass surgery
PDF
Pericardiocentesis
ARTERIAL CANNULATION.pptx
INTRA AORTIC BALLON PUMP (IABP)
Anticoagulation and haemostasis during cardiopulmonary bypass
Cardiomyopathy and anesthetic concern
Transesophageal echocardiography
Fluid responsiveness in critically ill patients
Invasive blood pressure_monitoring
Pericardiocentesis
DHCA
Cardiac output monitoring
Pulmonary artery catherisation
BMV,PTMC,BALLOON MITRAL VALVOTOMY, BAL, VIRBHAN BALAI, DR VIRBHAN
Pulmonary artery catheter
ALPHA STAT & PH STAT.pptx
Double lumen tubes
cardiac output pptx
Airway adjuncts and management in ACLS
Anaesthesia for cardiopulmonary bypass surgery
Pericardiocentesis
Ad

Similar to Pulmonary artery-catheter2 (20)

PPTX
Pulmonary artery catheter
PDF
pulmonaryarterycatheter-151008070656-lva1-app6892.pdf
PPT
Hemodynamics
PPTX
Pulmonary capillary wedge pressure or PCWP.pptx
PPT
Hemodynamics
PPTX
Cardiovascular monitoring Part II
PPT
Pulmonary artery Catheter
PPTX
Hemodynamic monitoring
PPTX
pulmonaryarterycatheter-151008070656-lva1-app6892 (1) (1).pptx
PPTX
Right heart cathterization AL-AMIN.pptx
PPTX
PA cathrater ashish.pptx
PPT
HEMODYNAMICS objectives, indication, contraindication
PPTX
Cardiovascular monitoring final ppt.pptx
PDF
Swan-Ganz-catheterisation_amit-panjwani.pdf
PPTX
Hemodynamic Monitoring .pptx
PPTX
Raper, Ray — Charming the Yellow Snake: Pulmonary Artery Catheters
PPSX
CVP Pulmonary artery wedge pressure monitoring: Physiology
PPT
RTC PA CATHETER.ppt
PPTX
Monitoring Invasif Anesthesai in java .
PPTX
PA CATHETER (1).pptx
Pulmonary artery catheter
pulmonaryarterycatheter-151008070656-lva1-app6892.pdf
Hemodynamics
Pulmonary capillary wedge pressure or PCWP.pptx
Hemodynamics
Cardiovascular monitoring Part II
Pulmonary artery Catheter
Hemodynamic monitoring
pulmonaryarterycatheter-151008070656-lva1-app6892 (1) (1).pptx
Right heart cathterization AL-AMIN.pptx
PA cathrater ashish.pptx
HEMODYNAMICS objectives, indication, contraindication
Cardiovascular monitoring final ppt.pptx
Swan-Ganz-catheterisation_amit-panjwani.pdf
Hemodynamic Monitoring .pptx
Raper, Ray — Charming the Yellow Snake: Pulmonary Artery Catheters
CVP Pulmonary artery wedge pressure monitoring: Physiology
RTC PA CATHETER.ppt
Monitoring Invasif Anesthesai in java .
PA CATHETER (1).pptx
Ad

Recently uploaded (20)

PPTX
Critical Issues in Periodontal Research- An overview
PPTX
Nutrition needs in a Surgical Patient.pptx
PDF
Integrating Traditional Medicine with Modern Engineering Solutions (www.kiu....
PDF
FMCG-October-2021........................
PPTX
Surgical anatomy, physiology and procedures of esophagus.pptx
PPTX
sexual offense(1).pptx download pptx ...
PPTX
Journal Article Review - Ankolysing Spondylitis - Dr Manasa.pptx
PPT
fiscal planning in nursing and administration
PPTX
Geriatrics_(0).pptxxvvbbbbbbbnnnnnnnnnnk
PPTX
This book is about some common childhood
PPTX
Acute Abdomen and its management updates.pptx
PPT
intrduction to nephrologDDDDDDDDDy lec1.ppt
PPTX
Genetics and health: study of genes and their roles in inheritance
PPTX
presentation on causes and treatment of glomerular disorders
PDF
Diabetes mellitus - AMBOSS.pdf
PPTX
Hyperthyroidism, Thyrotoxicosis, Grave's Disease with MCQs.pptx
PDF
495958952-Techno-Obstetric-sminiOSCE.pdf
PPTX
Type 2 Diabetes Mellitus (T2DM) Part 3 v2.pptx
PDF
NCCN CANCER TESTICULAR 2024 ...............................
PPTX
gut microbiomes AND Type 2 diabetes.pptx
Critical Issues in Periodontal Research- An overview
Nutrition needs in a Surgical Patient.pptx
Integrating Traditional Medicine with Modern Engineering Solutions (www.kiu....
FMCG-October-2021........................
Surgical anatomy, physiology and procedures of esophagus.pptx
sexual offense(1).pptx download pptx ...
Journal Article Review - Ankolysing Spondylitis - Dr Manasa.pptx
fiscal planning in nursing and administration
Geriatrics_(0).pptxxvvbbbbbbbnnnnnnnnnnk
This book is about some common childhood
Acute Abdomen and its management updates.pptx
intrduction to nephrologDDDDDDDDDy lec1.ppt
Genetics and health: study of genes and their roles in inheritance
presentation on causes and treatment of glomerular disorders
Diabetes mellitus - AMBOSS.pdf
Hyperthyroidism, Thyrotoxicosis, Grave's Disease with MCQs.pptx
495958952-Techno-Obstetric-sminiOSCE.pdf
Type 2 Diabetes Mellitus (T2DM) Part 3 v2.pptx
NCCN CANCER TESTICULAR 2024 ...............................
gut microbiomes AND Type 2 diabetes.pptx

Pulmonary artery-catheter2

  • 1. Pulmonary artery catheter for cardiac pressure monitoring and its role in anesthetic practice Dr. Shalini Saini University College of Medical Sciences & GTB Hospital, Delhi
  • 2. Pulmonary artery catheter • Introduction • Insertion technique • Indications • Complications • Abnormal pulmonary artery and wedge pressure waveform
  • 3. Introduction • In 1970, Swan,Ganz and colleague introduced pulmonary artery catheter
  • 4. Pulmonary artery catheter • Standard : 7-9 Fr circumference • 110cm length at 10cm intervals • Four internal lumen- 1. Distal-pulmonary artery pressure monitoring 2. Proximal-30cm for CVP monitoring 3. It leads to balloon near the tip 4. It houses wires for a temperature thermistor
  • 5. Uses of pulmonary artery catheter • Assessment of volume status in patients undergoing major surgeries • Cardiac output measurement by thermodilution technique • Various hemodynamic parameters-pulmonary artery pressure, pulmonary capillary wedge presssure,CVP,systemic vascular resistance, pulmonary vascular resistance. • Respiratory or oxygen transport measurement-mixed venous oximetry.
  • 6. Insertion Sites of insertion • Right internal jugular vein (preferred) • Left internal jugular vein (2nd choice) • Subclavian vein (disadvantages) • External jugular vein ( superficial location but tortous) • Antecubital vein • Femoral vein *After successful venous cannulation, there might be difficulty in advancement of the catheter due to abnormal venous anatomy. - most common: persistence of left superior vena cava.
  • 7. RA RV PA IJV-right 20cm 30cm 45cm left 25cm 35cm 50cm Antecubital –rt 50cm 65cm 80cm -lt 55cm 70cm 85cm Femoral v 40cm 50cm 65cm Subclavian v 10cm 25cm 40cm Distances to right atrium, right ventricle and pulmonary artery
  • 8. Pressure Average (mm Hg) Range (mm Hg) Right Atrium a wave 6 2-7 v wave 5 2-7 Mean 3 1-5 Right Ventricle Peak systolic 25 15-30 End-diastolic 6 1-7 Pulmonary Artery Peak systolic 25 15-30 End-diastolic 9 4-12 Mean 15 9-19 Pulmonary Artery Wedge Mean 9 4-12 Left Atrium Mean 8 2-12 Left Ventricle Peak systolic 130 90-140 End-diastolic 8 5-12 Normal Cardiovascular Pressures
  • 9. Wave form recorded during passage of pulmonary artery catheter • Right atrial pressure resembles central venous pressure waveform • Right ventricular pressure shows higher systolic pressure • Pulmonary artery pressure shows diastolic step up • Pulmonary artery wedge pressure similar morphology as right atrial pressure but a,c v waves appear later
  • 10. Temporal relationships between systemic arterial pressure,pulmonary artery pressure, central venous pressure and pulmonary artery wedge pressure -PAP upstroke precedes radial artery pressure upstroke -Wedge pressure a wave follows ECG R wave
  • 11. Three-zone model of pulmonary vasculature -described by West and colleague -tip of PAC should lie in zone3 -supine position favours zone3 condition
  • 13. Indications 1. Patients undergoing cardiac surgery with • Poor left ventricular compliance(ejection fration <0.4, LVEDP>18mm hg) • Left wall motion abnormality • Recent MI (<6 Months) • Left main coronary lesion • Valvular lesion • Presence of pulmonary artery hypertension
  • 14. 2. Major procedures involving large fluid shifts or blood loss in patients with- • Cardiogenic or septic shock or with multiple organ failure • Hemodynamic instability requiring ionotropes or intra-aortic balloon counterpulsation • Hepatic transplantation • Massive ascites requiring major surgery • Surgery of aorta requiring cross-clamping • Large abdomino-perineal resection etc.
  • 15. 3. Intensive care unit • To measure pulmonary artery and pulmonary capillary wedge pressure • To measure cardiac output by thermodilution • To obtain intracavitary electrocardiogram • To perform atrial or ventricular pacing • To allow infusion of drugs • To perform angiography • To detect venous air embolism 4. Continous mixed venous oximetry - To assess the adequacy of perfusion
  • 16. Recommendations for perioperative use of PACs (AHA 2007 guidelines) • Class 2b-(level of evidence:B) Use of PAC is reasonable in patients at risk for major hemodynamic disturbances easily detected by PAC. However, decision must be based on three parameters- a. disease b. surgical procedure c. practice setting (Experience & interpretation) • Class 3-(level of evidence:A) Routine use of PAC perioperatively, especially low risk of hemodynamic disturbances, is not recommended.
  • 17. Pulmonary Artery Catheterisation and outcome controversies • PAC use in 5735 patients in first 24 hrs intensive care associated with increased mortality, hospital stay and cost.(Connors etal,1997) • Three trials including 3468 patients showed no effect on mortality but higher incidence of adverse effects(Harvey etal,2005; The ESCAPE Trial,2005; Sandham etal,2003) • A review of 53312 patients from National Trauma Data Bank showed -No mortality benefit in patients treated with PAC -Injury scale greater: mortality decreased(Friese etal,2006) • In mixed medical and surgical population,APACHE scores <25 -increased mortality >31 -significant benefit (Chittock etal,2004)
  • 18. • A group of experienced cardiac anesthesiologists and surgeons blinded to information from pulmonary artery catheterisation during CABG surgery were unaware of 65% of severe hemodynamic abnormalities.(Waller and Kaplan) • ICU physicians were unable to accurately predict hemodynamic data on clinical grounds and 60% made at least one change in therapy and 33% changed their diagnosis based on PAC data.(Iberti and Fisher)
  • 19. Contraindications (Kaplan) Absolute contraindications • Tricuspid or pulmonary stenosis • Right atrial or ventricular mass • Tetralogy of Fallot Relative contraindications • Severe arrhythmias • Coagulopathy • Newly inserted pacemaker wires
  • 20. Complications 1. Catheterisation a. Arrythmia-primary complication -most common premature ventricular contractions -ventricular fibrillation b. Right bundle branch block c. Complete heart block Treatment- balloon deflated and catheter withdrawn to right atrium
  • 21. 2. Catheter residence a. Catheter knotting -suspected when difficulty in withdrawing -diagnosed with chest x-ray -untied by radiologist b.Thromboembolism –rising incidence -increased with antifibrinolytic drugs c. Pulmonary infarction d. Infection ,endocarditis e. Endocardial damage, cardiac valve injury f. Thrombocytopenia (heparin induced)
  • 22. g. Pulmonary artery rupture -Incidence: 0.064%-0.20% -Increased risk: female sex, hypothermia, anticoagulation, advanced age, pulmonary hypertension, mitral stenosis, coagulopathy, distal placement catheter, balloon hyperinflation -Hallmark:hemoptysis and exsanguination -Treatment: 1. Resuscitation-adequate oxygenation and ventilation 2. If hemorrhage minimal,with coagulopathy-correct coagulopathy 3. Protection of uninvolved lung by-tilting patient to affected side, placement of double lumen endotracheal tube 4. Stop hemorrhage- apply PEEP, Bronchial blockers, resection. 5. Severe hemorrhage with recurrent bleeding-transcatheter coil embolisation.
  • 23. Abnormal pressure waveforms A. Artifact Overwedging occurs when balloon overinflated/distal migration of cathter/eccentric balloon inflation.
  • 24. B.Pathophysiologic changes 1.Mitral regurgitation -Tall v waves in waveform with bifid appearance -PAP upstroke steeper -Wedge pressure prominent v wave with gradual upstroke -Wedge pressure overestimates left ventricular filling pressure -Tall v wave:hypervolemia,CHF, VSD.
  • 25. 2.Mitral stenosis -Mean wedge pressure increased -y descent slurred due to obstruction to bloood flow -Similar abnormalities-left atrial myxoma, left ventricle infarction, pericardial constriction,aortic stenosis, systemic hypertension
  • 26. 3.Pericardial constriction -prominent a and v waves -steep x and y descent -M or W configuration in CVP trace -diastolic ‘dip and plateau’ pattern or square root sign due to early diastolic ventricular filling -mid diastolic h wave (plateau) due to interruption in flow due to restrictive shell
  • 27. 4.Myocardial ischemia • First time used in patient with acute MI. • PAP normal relatively • PAWP slightly elevated • PAWP morphology abnormal -Tall a waves due to diastolic dysfunction
  • 28. Condition Site of Discrepancy Cause of Discrepancy Positive end-expiratory pressure Mean PAWP > mean LAP Creation of lung zone 1 or 2 or pericardial pressure changes Pulmonary arterial hypertension PADP > mean PAWP Increased pulmonary vascular resistance Pulmonary veno-occlusive disease Mean PAWP > mean LAP Obstruction to flow in large pulmonary veins Mitral stenosis Mean LAP > LVEDP Obstruction to flow across the mitral valve Mitral regurgitation Mean LAP > LVEDP Retrograde systolic v wave raises mean atrial pressure Ventricular septal defect Mean LAP > LVEDP Antegrade systolic v wave raises mean atrial pressure Tachycardia PADP > mean LAP > LVEDP Short diastole creates pulmonary vascular and mitral valve gradients Overestimation of Left Ventricular End-Diastolic Pressure
  • 29. Condition Site of Discrepacy Cause of Discrepancy Diastolic dysfunction Mean LAP < LVEDP Increased end-diastolic a wave Aortic regurgitation LAP a wave < LVEDP Mitral valve closure before end-diastole Pulmonic regurgitation PADP < LVEDP Bidirectional runoff for pulmonary artery flow Right bundle branch block PADP < LVEDP Delayed pulmonic valve opening After pneumonectomy PAWP < LAP or LVEDP Obstruction of pulmonary blood flow Underestimation of Left Ventricular End-Diastolic Pressure
  • 30. Additional uses of pulmonary artery catheter 1. Thermodilution cardiac output monitoring • Principle: Stewart-Hamilton equation Q = V(Tb-Ti)K1.K2 Tb(t)dt Q = Cardiac output V = Injectate volume Tb = Blood temperature Ti = Injectate temperature K1 = Density factor: (sp heat)(sp gravity)injectate (sp heat)(sp gravity)blood K2 = A computation constant which includes heat change in transit,dead space of the catheter,injection rate, adjusts units to l/min Tb(t)dt = change in blood temperature as a function of time
  • 31. 2. Mixed venous oximetry Svo2 = Sao2- Vo2 / Q×1.36×Hb Svo2 = mixed venous hemoglobin saturation(%) Sao2 = arterial hemoglobin saturation(%) Vo2 = oxygen consumption(ml/min) Q = Cardiac output (l/min) Hb = hemoglobin concentration(g/dl) * Mixed venous hemoglobin saturation determined by sampling from PAC either intermittently or continous
  • 32. 3. Right Ventricular Ejection Fraction RVEDV = SV/RVEF RVEDV = Right ventricular end diastolic volume (ml) SV = Stroke volume RVEF = Right ventricular ejection fraction 4. Derived Hemodynamic Variables SVR = MAP-CVP × 80 CO PVR = MPAP-PAWP×80 CO SVR = systemic vascular resistance PVR = pulmonary vascular resistance MAP = mean arterial pressure CVP = central venous pressure MPAP = mean pulmonary artery pressure PAWP = pulmonary artery wedge pressure CO = cardiac output
  • 33. References • Ronald.D.Miller: Pulmonary artery catheter monitoring. Cardiovascular monitoring 7th ed:1297-1314. • Kaplan: Anesthesia techniques for cardiac surgical procedures;399-408. • Circulation. 2007;116:e418-e500 • Blitt: Monitoring. Pulmonary artery cathterisation;221-263.

Editor's Notes

  • #13: It is difficult to measurelvvolm but lvvol correlates with the lvedp which is indirectly related to rap affected by the various factors.