French leader in electrosurgery since 1947
Optima II
Universal electrosurgical platform with latest generation microprocessors for the providing of energies which are in
real time adapted to the evolution of the tissues (Power Feedback).
Reference: V10GOPT4A /V10GOPT4
Full electrosurgical Endosection Argon system
unit 370 W
Specific wave form Argon module for a com-
Complete electrosur- dedicated to endoscopic plete solution: APC for the
gical units 370 W with a polypectomy hepatic and endoscopic
wide range of monopolar surgery
and bipolar effects
VESSEL SEALING
The gold standard of
A unique system Safe and efficient up to 7 mm
bipolar plasma resection
power dedicated for bi- which can seal, dissect vessel diameter with Validation
polar TUR and hyste- and cut in one instru- signal after sealing process
roresection procedures ment, dedicated for
Thyroid and delicate
procedures
Tél : 00 33 (1) 69 20 69 69, Fax : 00 33 (1) 60 13 97 47, Mail : info@[Link], [Link]
LAMIDEY NOURY MEDICAL, Z.A. Les godets, 3, rue des petits ruisseaux, F-91370 Verrières le Buisson, France 1
RCS Evry 445 145 105 Siret 445 145 105 00018 TVA FR 49445145105 Code APE 331B
French leader in electrosurgery since 1947
Special features:
Friendly user interface with an LCD touch screen without button with 8,66” size.
More than 80 programs for all surgeries specialties.
Saving more than 1 000 personal programs.
4 High Frequency outputs : 2 monopolars and 2 bipolars
Saline cut with PLASMA technology : RTUP/RTUV
Saline cut with PLASMA Technology : uterine resection
Fulguration / Spray with the Argon Module System
Twin coagulation
Recognition and traceability of the intruments
Reusable Cutting and Sealing forceps :
* THERMOCISION forceps :
- Completely reusable
- Dissection, sealing and cutting in one act
* THERMOCUT forceps :
- Completely reusable and autoclovable
- Safe and efficient sealing up to 7 mm Ø vessels
- Completely dismountable for safer cleaning
- Single use blade
- Cable not attached
* THERMOCLAMP forceps:
- Completely reusable
- open surgery clamps in 16, 22 and 32 cm
Tél : 00 33 (1) 69 20 69 69, Fax : 00 33 (1) 60 13 97 47, Mail : info@[Link], [Link]
LAMIDEY NOURY MEDICAL, Z.A. Les godets, 3, rue des petits ruisseaux, F-91370 Verrières le Buisson, France 2
RCS Evry 445 145 105 Siret 445 145 105 00018 TVA FR 49445145105 Code APE 331B
French leader in electrosurgery since 1947
INPUT FEATURES
Main supply 220 V –240 v~ 50 or 60 Hz
Safety Class 1 type CF
Maximum power 1200 VA (600 W)
OUTPUT FEATURES
Waveform sinuswave
Frequency emitted 450 KHz
Modulation frequency 21 KHz
MONOPOLAR CUT
Autocut PURE CUT: 360 W / 250 Ω
BLEND 1 : 330 W / 250 Ω, light haemostatic effect
BLEND 2 : 320 W / 250 Ω, deep haemostatic effect
ENDOSECTION 1/2 : 200 W / 250 Ω for gastrointestinal endoscopy (polypectomy)
Forced cut FORCED PURE CUT : 370 W / 450 Ω, forced cut
Forced Soft HEMOCUT : 340 W / 450 Ω, forced cut with light haemostatic effect
FORCED HEMOCUT : 330 W / 450 Ω, forced cut deep haemostatic effect
SPHINCTEROCUT: 200 W / 450 Ω pulsed cut for sphincterotomy
MONOPOLAR CUT UNDER IRRIGATION (glycine)
HYSTEROCUT : 330 W / 250 Ω autocut for hysteroscopy resection
UROCUT P: 350 W / 450 Ω for transurethral resection of prostate (TURP)
UROCUT V: 330 W / 450 Ω Forced cut for transurethral resection of bladder (TUR)
MONOPOLAR COAGULATIONS
Soft coagulation 170 W / 250 Ω, soft contact coagulation for vascular surgery, pediatric and micro surgery
Desiccation 210 W / 450 Ω, forced contact coagulation for all surgeries
Fulguration 100 W / 900 Ω, spray coagulation for homeostasis of large area
TEAM COAG 100 W / 900 Ω, simultanoeus coagulation from 2 monopolar outputs
Tél : 00 33 (1) 69 20 69 69, Fax : 00 33 (1) 60 13 97 47, Mail : info@[Link], [Link]
LAMIDEY NOURY MEDICAL, Z.A. Les godets, 3, rue des petits ruisseaux, F-91370 Verrières le Buisson, France 3
RCS Evry 445 145 105 Siret 445 145 105 00018 TVA FR 49445145105 Code APE 331B
French leader in electrosurgery since 1947
Coagulation with ARGON (in option), gasflow : 0 to 10 L/min
Cut under ARGON Forced cut , 370 W / 450 Ω
Coagulation under argon forced contact coagulation, 210 W / 450 Ω
Forced Argon plasma Coagulation by ionized gas, 100 W / 900 Ω (open surgery and gastrointestinal endoscopy)
Pulsed Argon plasma Coagulation by ionized gas, 100 W / 900 Ω (gastrointestinal endoscopy)
BIPOLAR CUT
Pure cut 200 W / 150 Ω cut for bipolar scissors
PLASMA EDGE CUT UNDER SALINE LIQUID (NaCl 0,9%)
THIN LOOP TURB & uterine resection
THICK LOOP TURP
VAPORIZATION TURP & uterine resection
BIPOLAR COAGULATION
SOFT Coagulation 100 W / 25 Ω soft coagulation, for neurosurgery and laroscopic
FORCED Coagulation 170 W / 750 Ω for all tissues (vascularized and adipose tissues)
SALINE Coagulation 140 W / 75 Ω for coagulation under saline liquid
VESSEL SEALING SYSTEM
Maximum power: 150 W / 30 Ω
Vessel sealing until 7mm of diameter with reusable forceps.
Jaws are completely isolated: thermal spread doesn’t exceed 2mm.
Action reverse mode for Thermocut handle: clamping pressure is superior to 700mmHG.
THERMOCLAMP forceps for open surgery, with a vessel clamping device
THERMOCUT 10 mm forceps for open surgery (20cm) and laroscopy (30cm), with vessel autoclamping system and integrated
cut system, straight jaws (10 mm) and angled jaws (5 mm)
THERMOCUT (5 mm) forceps for open surgery (20cm), laroscopy (30cm), with vessel autoclamping system and integrated cut
system
THERMOCISION forceps for dissection, homeostasis and cutting in one act (thyroidectomie)
Adjustment of the power by selecting the forceps’s type.
THERMOCONTROL: Vessel sealing process monitoring with sound signal at the end of cycle and diagnosis of incident.
Tél : 00 33 (1) 69 20 69 69, Fax : 00 33 (1) 60 13 97 47, Mail : info@[Link], [Link]
LAMIDEY NOURY MEDICAL, Z.A. Les godets, 3, rue des petits ruisseaux, F-91370 Verrières le Buisson, France
RCS Evry 445 145 105 Siret 445 145 105 00018 TVA FR 49445145105 Code APE 331B
4
French leader in electrosurgery since 1947
ERGONOMY
User’s interface LCD touch-screen
HF power display Digital display in maximum Watts
Adjustments 1 W steps in the touch-screen
Memorizations Storage of interventions parameters :mode of cut and coagulation, power adjustments
Initial programs 80 programs classified by surgical specialties
Personal programs Memorization
ments).
of surgeons’ adjustments (Possible memorization of several thousand adjust-
Update USB port for software update
International plugging for hand switches with a 3 pins in line plug and for cable with one 4mm
male plug
Monopolar outputs
Optima II : 2 outputs
Plugging for wire with two 4 mm diameter male plug ( spreading 28.5 mm)
Bipolar outputs
Optima II : 2 outputs
1 socket for :
Twin footswitches Monopolar and bipolar cut
Monopolar and bipolar coagulation
2 sockets for :
Single footswitches Bipolar coagulation
Vessel sealing system
Hand control Monopolar cut and coagulation control on handswitch
Automatic bipolar coagu- Automatic start and stop by impedance contact sensing on forceps. 3 possible start delay.
lation
Tél : 00 33 (1) 69 20 69 69, Fax : 00 33 (1) 60 13 97 47, Mail : info@[Link], [Link]
LAMIDEY NOURY MEDICAL, Z.A. Les godets, 3, rue des petits ruisseaux, F-91370 Verrières le Buisson, France 5
RCS Evry 445 145 105 Siret 445 145 105 00018 TVA FR 49445145105 Code APE 331B
French leader in electrosurgery since 1947
SAFETIES
Neutral Electrode Safety - Monitoring of skin contact with single use adhesive double plate
- Audible and visual alarm in case of contact failure or short circuit, or electrical discon-
tinuity with inhibition of HF power.
- Compatible with adult and children plates
Neonatal plate safety Limitation of monopolar output power up to 50 W, when used with neonatal adhesive dou-
ble plate.
Single plates (option) Monitoring of electrical continuity between unit and neutral electrode.
HF control power Monitoring of HF power emitted, with automatic power shutdown in case of excessive HF
Power ( IEC 60601-2-2).
HF leakage Ihf < 100mA / 200 Ω (< 130 mA / 200 Ω in fulguration mode)
Electrical safeties class 1, CF type (I <1µA in Normal Conditions)
Defibrillation proof device
Short circuit protection > 10 s
Thermal safety Forced ventilation
HF voltage Regulated (automatic limitation of maximum voltage)
Limited activation Automatic stop after 1 minute of continuous activation. Normal working is restored after
interruption of the control.
Auto check starting When power on, the unit is checking all accessories connected and internal circuits
Tél : 00 33 (1) 69 20 69 69, Fax : 00 33 (1) 60 13 97 47, Mail : info@[Link], [Link]
LAMIDEY NOURY MEDICAL, Z.A. Les godets, 3, rue des petits ruisseaux, F-91370 Verrières le Buisson, France
RCS Evry 445 145 105 Siret 445 145 105 00018 TVA FR 49445145105 Code APE 331B
6