0% found this document useful (0 votes)
180 views2 pages

9491-PS Intrinsically Safe Power Supply

The 9491-PS power supply module provides 12V DC intrinsically safe power for Zone 1 hazardous areas. It can be mounted on a DIN rail or backplane and is certified for ATEX and IECEx zones. Multiple modules can be connected to provide higher power levels. It takes a 24V DC input and produces a 12V DC output to power Ethernet modules in Zone 1 areas. LED indicators show input and output power status and faults.

Uploaded by

mehdi227
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
180 views2 pages

9491-PS Intrinsically Safe Power Supply

The 9491-PS power supply module provides 12V DC intrinsically safe power for Zone 1 hazardous areas. It can be mounted on a DIN rail or backplane and is certified for ATEX and IECEx zones. Multiple modules can be connected to provide higher power levels. It takes a 24V DC input and produces a 12V DC output to power Ethernet modules in Zone 1 areas. LED indicators show input and output power status and faults.

Uploaded by

mehdi227
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

12V DC Intrinsically Safe Power Supply

9491-PS

Isolated power supply Zone 2 mountable DIN-rail or backplane mounting ATEX / IECEx certified FM / CSA approvals (pending)

200mA @10.9V DC - Ex ia IIB output 400mA @11.8V DC - Ex ib IIB output Power over Ethernet option Multiple outputs achieved by ganging 9491-PS modules using 24V DC power distribution backplane

The 9491-PS Power Supply is the preferred method for supplying the 9460-ET series of instrinsically safe Ethernet modules and is based on an isolating power supply. It takes a 24V DC safe area / Zone 2 supply and produces an intrinsically safe, 12V DC nominal output capable of powering the Ethernet modules mounted in a Zone 1 hazardous area. Each 9491-PS can power a single Ethernet module. In order to provide multiple outputs required for several Ethernet modules, the 9491-PS power supply module is ganged up to the required number of ways, either DIN-rail mounted or using the power distribution backplane to simplify the 24VDC input connection to the modules.

The 9491-PS module has LED power indication for both input and output along with internal current limiting and electronic auto-reset circuit breaker action to protect the module in the event of its output being short circuited or overloaded. This also minimises the power dissipation during the fault to a negligible level, thus improving reliability. The output can be from either the Ex ia IIB or Ex ib IIB output connectors depending upon application. The ib IIB output providing a higher useable output power where the Gas Group and Zone allows.

EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283 AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899 ASIA PACIFIC Tel: +65 487 7887 Fax: +65 487 7997 E-mail: enquiry@[Link] Web site: [Link]

Oct 2008

SPECIFICATION
See also System Specification

DIMENSIONS (mm)
Optional TH5000 tag holder for individual module identification. Accepts tag label 25 x 12.5 0.5mm, 0.2mm thick Intrinsically safe connectors 15.8 +/ 0.2 104.8

POWER INPUT Separately powered Input voltage 24V DC (2030V) Input current 350mA Input protection Fuse + supply reversal diode POWER OUTPUT Ex ia IIB output Minimum o/p voltage
12.1 9.7 12.1V minimum

Equivalent circuit
6W maximum

Output current (mA)

400

Ex ib IIB output Minimum o/p voltage


12.1 11.6 Output voltage (V) 12.1V minimum

Equivalent circuit
1.3W maximum

ENVIRONMENTAL Ambient temp Operating 0C to +70C Storage 20C to +70C Relative Humidity 5 to 95% RH (non-condensing) Ingress Protection IP20 to BS EN 60529 (Additional protection by means of enclosure)

Output current (mA)

400

Connectors 9491-PS is supplied with two IS output connectors. (When using crimp ferrules for the IS connectors the metal tube length should be 12mm and the wire trim length 14mm.) ISOLATION Isolation - input to output Um = 253V rms SAFETY Location of module Safe area, Zone 2*, Division 2* Location of field wiring Ex ia output Zone 0, IIB hazardous area or Class 1, Div 1, Groups C, D hazardous location* Ex ib output Zone 1, IIB hazardous area or Class 1, Div 1, Groups C, D hazardous location* Certification Code See approvals Safety description See certificate MECHANICAL Mounting DIN rail or power distribution backplane Dimensions See diagram Weight 130 g

LED INDICATORS
OFF Pwr (green) IS (green) 24V power fail IS power fail Flash N/A ON 24V power OK

121.8

Output voltage (V)

output overload IS power OK or short circuit present

* certification pending

EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283 AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899 ASIA PACIFIC Tel: +65 6 487 7887 Fax: +65 6 487 7997 E-mail: enquiry@[Link] Web site: [Link]

Oct 2008