Project
Job Ref.
Section
Sheet no./rev.
Highland Engineering P.C.
700 Industrial Drive
Suite A
Cary, IL 60013
RSF
Date
Chk'd by
10/22/2010
Date
App'd by
Date
COLUMN BASE PLATE DESIGN (AISC360-05)
In accordance with the LRFD method
TEDDS calculation version 2.0.00;
1.5 "
19.0 "
W 12x96
250.0 kips
Bolt diameter - 0.8 "
Bolt embedment - 18.0 "
Flange/base weld - 0.3 "
Web/base weld - 0.2 "
2800.0 kip_in
20.0 kips
4.42 ksi
1.5 "
20.8 kips
Plan on baseplate
1.5 "
1.5 "
19 "
Elevation on baseplate
Design forces and moments
Axial force;
Pu = 250.0 kips; (Compression)
Bending moment;
Mu = 2800.0 kip_in
Shear force;
Fv = 20.0 kips
Eccentricity;
e = ABS(Mu / Pu) = 11.200 in
Anchor bolt to center of plate;
f = N/2 - e1 = 9.500 in
Column details
Column section;
W 12x96
Depth;
d = 12.700 in
Breadth;
bf = 12.200 in
Flange thickness;
tf = 0.900 in
Web thickness;
tw = 0.550 in
Baseplate details
Depth;
N = 22.000 in
Breadth;
B = 22.000 in
Thickness;
tp = 2.750 in
Design strength;
Fy = 36.0 ksi
Foundation geometry
Member thickness;
ha = 20.000 in
Dist center of baseplate to left edge foundation;
xce1 = 50.000 in
Dist center of baseplate to right edge foundation;
xce2 = 50.000 in
Dist center of baseplate to bot edge foundation;
yce1 = 50.000 in
Dist center of baseplate to top edge foundation;
yce2 = 50.000 in
Holding down bolt and anchor plate details
Total number of bolts;
Nbolt = 4
Bolt diameter;
do = 0.750 in
Project
Job Ref.
Section
Sheet no./rev.
Highland Engineering P.C.
700 Industrial Drive
Suite A
Cary, IL 60013
RSF
Date
10/22/2010
Chk'd by
Bolt spacing;
sbolt = 19.000 in
Edge distance;
e1 = 1.500 in
Minimum tensile strength of steel;
Fy = 36 ksi
Compressive strength of concrete;
fc = 4 ksi
Date
App'd by
Date
Strength reduction factors
Compression;
c = 0.65
Flexure;
b = 0.90
Weld shear;
v = 0.75
Plate cantilever dimensions
Area of base plate;
A1 = B N = 484.000 in2
Maximum area of supporting surface;
A2 = (N + 2 lmin) (B + 2 lmin) = 10000.000 in2
Nominal strength of concrete under base plate;
Pp = 0.85 f'c A1 min((A2 / A1), 2) = 3291.2 kips
Plate bending coefficient X;
X = (4 d bf) / (d + bf)2 min(1.0, Pu / (Pp c)) = 0.12
Plate bending coefficient ;
l = min(1, 2 (X) / (1 + (1 - X))) = 0.35
Bending line cantilever distance m;
m = (N - 0.95 d) / 2 = 4.967 in
Bending line cantilever distance n;
n = (B - 0.8 bf) / 2 = 6.120 in
Yield line theory cantilever distance n;
n = (d bf) / 4 = 3.112 in
Maximum bending line cantilever;
l = max(m, n, l n') = 6.120 in
Check eccentricity
Maximum bearing stress;
fp,max = 0.85 f'c c min((A2 / A1), 2) = 4.42 ksi
Maximum bearing pressure;
qmax = fp,max B = 97.24 kips/in
ecrit = N / 2 - Pu / (2 qmax) = 9.715 in
Critical eccentricity;
e > ecrit so loads cannot be resisted by bearing alone. Therefore consider as a large moment
Plate dimensions adequate as (f + N/2)2 >= (2 Pu (e + f))/qmax and a real solution for bearing length exists
Bearing length - quadratic solution 1;
Y1 = (f + N/2) + ((f + N/2)2 - (2 Pu (e + f))/qmax) = 38.215 in
Bearing length - quadratic solution 2;
Y2 = (f + N/2) - ((f + N/2)2 - (2 Pu (e + f))/qmax) = 2.785 in
Bearing length;
Y = min(Y1, Y2) = 2.785 in
Tension force in bolts;
Tu = qmax Y - Pu = 20.8 kips
Max tension in single bolt;
Trod = Tu / (Nbolt/2) = 10.4 kips
Base plate yielding limit at bearing interface
Required plate thickness;
tp,req = ((4 fp,max Y (l - Y/2))/(b Fy)) = 2.680 in
PASS - Thickness of plate exceeds required thickness
Base plate yielding limit at tension interface
Distance from bolt CL to plate bending lines;
x = abs(l - e1) = 4.620 in
Plate thickness required;
tp,req = 2.11 ((Tu x)/(B Fy)) = 0.736 in
PASS - Thickness of plate exceeds required thickness
Frictional shear resistance
Steel / concrete friction coefficient;
= 0.4
Frictional shear resistance;
Vn = min(v qmax Y, v 0.2 f'c Y B, v 800psi Y B) =
36.77 kips
PASS - Frictional shear resistance exceeds applied shear
Project
Job Ref.
Section
Sheet no./rev.
Highland Engineering P.C.
700 Industrial Drive
Suite A
Cary, IL 60013
RSF
Date
10/22/2010
Chk'd by
Date
App'd by
Date
Flange weld
Flange weld leg length;
tfw = 0.2500 in
Tension capacity of flange;
Ptf = bf tf Fy = 395.3 kips
Force in tension flange;
Ftf = Mu / (d - tf) - Pu (bf tf) / Acol = 139.9 kips
Critical force in flange;
Ff = min(Ptf, max(Ftf, 0kips)) = 139.9 kips
Flange weld force per in;
Rwf = Ff / (2 bf - tw) = 5.9 kips/in
Electrode classification number;
FEXX = 70.0 ksi
Nominal weld stress;
Fw = v 0.60 FEXX (1.0 + 0.5 (sin(90deg))1.5) = 47.2500ksi
Design strength of weld per in;
Rnf = Fw twf / (2) = 10.4 kips/in
PASS - Available strength of flange weld exceeds force in flange weld
Longitudinal web weld
tww = 0.2500 in
Web weld leg length;
Web weld force per in;
Rwl = Fv / (2 (d - 2 tf)) = 0.9174 kips/in
Electrode classification number;
FEXX = 70.0 ksi
Nominal weld stress;
Fw = v 0.60 FEXX (1.0 + 0.5 (sin(90deg))1.5) = 47.2500ksi
Design strength of weld per in;
Rnl = Fw tww / (2) = 8.4 kips/in
PASS - Available strength of longitudinal web weld exceeds force in longitudinal web weld
ANCHOR BOLT DESIGN (ACI318-08)
TEDDS calculation version 2.0.00
Anchor bolt geometry
Type of anchor bolt;
Cast-in headed end bolt anchor
Diameter of anchor bolt;
da = 0.75 in
Number of bolts in x direction;
Nboltx = 2
Number of bolts in y direction;
Nbolty = 2
Total number of bolts;
ntotal = (Nboltx 2) + (Nbolty - 2) 2 = 4
Total number of bolts in tension;
ntens = (NboltN 2) + (Nbolty - 2) = 2
Spacing of bolts in x direction;
sboltx = 19 in
Spacing of bolts in y direction;
sbolty = 19 in
Number of threads per inch;
nt = 10
Effective cross-sectional area of anchor;
Ase = / 4 (da - 0.9743 in / nt)2 = 0.334 in2
Embedded depth of each anchor bolt;
hef = 18 in
Material details
Minimum yield strength of steel;
fya = 105 ksi
Minimum tensile strength of steel;
futa = min(1.9 fya, 125ksi) = 125 ksi
Compressive strength of concrete;
fc = 4 ksi
Concrete modification factor;
= 1.00
Strength reduction factors
Strength reduction factor tension of steel element; t,s = 0.75
Strength reduction factor shear of steel element; v,s = 0.70
Strength reduction factor concrete tension;
t,c = 0.65
Strength reduction factor concrete shear;
v,c = 0.70
Project
Job Ref.
Section
Sheet no./rev.
Highland Engineering P.C.
700 Industrial Drive
Suite A
Cary, IL 60013
RSF
Date
Chk'd by
10/22/2010
Date
App'd by
Date
Steel strength of anchor in tension (D.5.1)
Nominal strength of anchor in tension;
Nsa = Ase futa = 41.81 kips
Steel strength of anchor in tension;
Nsa = t,s Nsa = 31.36 kips
PASS - Steel strength of anchor exceeds max tension in single bolt
1' 7.0"
3' 4.5"
Check concrete breakout strength of anchor bolt in tension (D.5.2)
3' 4.5"
1' 7.0"
1' 6"
1' 8"
3' 4.5"
20.84 kips
3' 4.5"
8' 4"
Plan on foundation
Section A-A
Concrete breakout - tension
Stength reduction factor;
t = 0.65
Coeff for basic breakout strength in tension;
kc = 24
Breakout strength for single anchor in tension;
Nb = 16 (f'c 1 psi) hef5/3 1 in1/3 = 125.10 kips
Projected area for groups of anchors;
ANc = 3942 in2
Projected area of a single anchor;
ANco = 9 hef2 = 2916 in2
Min dist center of anchor to edge of concrete;
ca,min = 40.5 in
Mod factor for groups loaded eccentrically;
ec,N = min(1 / (1 + ((2 e'N) / (3 hef))), 1) = 1.000
Modification factor for edge effects;
ed,N = 1.0 = 1.000
Modification factor for no cracking at service loads; c,N = 1.250
Modification factor for uncracked concrete;
cp,N = 1.000
Nominal concrete breakout strength;
Ncbg = ANc / ANco ed,N c,N cp,N Nb = 211.40 kips
Concrete breakout strength;
Ncbg = t,c Ncbg = 137.41 kips
PASS - Breakout strength exceeds tension in bolts
Pullout strength (D.5.3)
Net bearing area of the head of anchor;
Abrg = 1.5 in2
Mod factor for no cracking at service loads;
c,P = 1.4000
Pullout strength for single anchor;
Np = 8 Abrg f'c = 48.00 kips
Nominal pullout strength of single anchor;
Npn = c,P Np = 67.20 kips
Pullout strength of single anchor;
Npn = t,c Npn = 43.68 kips
PASS - Pullout strength of single anchor exceeds maximum axial force in single bolt
Project
Job Ref.
Section
Sheet no./rev.
Highland Engineering P.C.
700 Industrial Drive
Suite A
Cary, IL 60013
RSF
Date
10/22/2010
Chk'd by
Date
App'd by
Date
Side face blowout strength (D.5.4)
As hef <= 2.5 min(ca1, ca2) the edge distance is considered to be far from an edge and blowout strength need not be
considered