FXS Series
DIN W48H48mm, Preset Counter/Timer
Features
Upgraded counting speed: 1cps/30cps/2kcps/5kcps
Selectable voltage input (PNP) or No-voltage input (NPN)
Addition of Up/Down input mode
Available to set a decimal point (Fixed decimal point of display)
Wide range of input power supply: 100-240VAC 50/60Hz
12-24VAC 50/60Hz, 12-24VDC universal
Selectable Counter/Timer by internal DIP switch
Various time range: Built-in micro computer (Micom)
Please read Caution for your safety in operation
manual before using.
Ordering Information
FX
S
Size
Digit
Item
Output
No mark Single preset
I
Indicator
DIN W48H48mm
9999 (4digit)
99999 (5digit)
FX
Counter/Timer
Specifications
FX4S
FX5S-I
Digit
4digit
5digit
Digit size
W3.8H7.6mm
W4H8mm
AC power
100-240VAC 50/60Hz
Power
supply
AC/DC power
12-24VAC 50/60Hz, 12-24VDC
Allowable voltage range
90 to 110% of rated voltage
AC power
Indication type: Max. 4.7VA, Single preset: Max. 5.7VA (100-240VAC 50/60Hz)
Power
Indication type: Max. 4.5VA, Single preset: Max. 5.6VA (12-24VAC 50/60Hz)
consumption AC/DC power
Indication type: Max. 2.8W, Single preset: Max. 3W (12-24VDC)
Max. counting speed for CP1, CP2 Selectable 1cps/30cps/2kcps/5kcps by internal DIP switch
Min. input INHIBIT input
Approx. 20ms
signal width RESET input
CP1, CP2 input Input logic is selectable
[Voltage input] Input impedance: 5.4k "H" level: 5-30VDC, "L" level: 0-2VDC
(INHIBIT)
Input
[No-voltage input] Impedance at short-circuit: Max. 1k, Residual voltage at short-circuit: Max. 2VDC,
RESET input
Impedance at open-circuit: Min. 100k
One-shot output time
0.05 to 5sec
Type
SPDT (1c)
Contact
Capacity 250VAC 3A at resistive load
Control
output
NPN open collector
Solid- Type
state
Capacity 30VDC Max. 100mA Max.
Memory protection
Approx. 10 years (When using non-volatile semiconductor memory)
External power
12VDC10% 50mA Max.
Insulation resistance
Min. 100M (at 500VDC megger)
Dielectric strength
2000VAC 50/60Hz for 1 minute
AC power
2kV the square wave noise (pulse width: 1) by the noise simulator
Noise
strength
DC power
500V the square wave noise (pulse width: 1) by the noise simulator
Mechanical
0.75mm amplitude at frequency of 10 to 55Hz (for 1 min.) in each X, Y, Z direction for 1 hour
Vibration
Malfunction
0.5mm amplitude at frequency of 10 to 55Hz (for 1 min.) in each X, Y, Z direction for 10 min.
Mechanical
300m/s (approx. 30G) in each X, Y, Z direction for 3 times
Shock
Malfunction
100m/s (approx. 10G) in each X, Y, Z direction for 3 times
Mechanical
Min. 10,000,000 operations
Relay
life cycle Electrical
Min. 100,000 operations (250VAC 3A at resistive load)
Environ- Ambient temperature 10 to 55, storage: -25 to 65
ment
Ambient humidity
35 to 85%RH
Model
Single preset
Indicator
Approval
Unit weight
Approx. 153g
Environment resistance is rated at no freezing or condensation.
J-42
Approx. 143g
Up/Down Counter/Timer
Connections
FX4S
(A)
Photoelectric
Sensors
FX5S-I
CP1 CP2 1 2
CP1 CP2 1 2
RESET
9 10
(INHIBIT)+12VDC 0V
(50mA)
9 10
1: Connection of PNP input
2: Connection of NPN input
CP2 (INHIBIT): Time Hold terminal
when using for timer.
Operated by a power ON start
when it is used as a timer.
(INHIBIT)+12VDC 0V
(50mA)
12
1
- +
CONTACT OUT:
250VAC 3A
SOURCE
RESISTIVE LOAD
100-240VAC 50/60Hz,
12-24VAC 50/60Hz, 12-24DC
4
-
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
(E)
Pressure
Sensors
100-240VAC 50/60Hz,
12-24VAC 50/60Hz, 12-24DC
(F)
Rotary
Encoders
SOURCE
(G)
Connectors/
Sockets
Dimensions
Bracket
(B)
Fiber
Optic
Sensors
RESET
11
91
Min. 55
(I)
SSRs / Power
Controllers
Min. 65
61
44.8
45
+0.6
0
48
(H)
Temperature
Controllers
Panel cut-out
45
(J)
Counters
+0.6
0
(K)
Timers
(unit: mm)
Input Connections
(M)
Tacho /
Speed / Pulse
Meters
Input logic: No-voltage (NPN) input
Solid-state input (Standard sensor: NPN output type sensor)
Sensor
RL
10
Brown
FXS Series
Blue
Contact input
Sensor
FXS Series
Brown
+12V
5.4
Inner
circuit
Black
Black
(NPN output)
5.4
Inner
circuit
FXS Series
+12V
Black
RL
10
Blue
Inner
circuit
5.4
0V
(PNP output)
CP1, CP2 (INHIBIT), RESET input
Sensor
Black
Blue
(PNP open
collector output)
Inner
circuit
(P)
Switching
Mode Power
Supplies
Please select the counting
speed as 1cps or 30cps
when it is used for counter.
FXS Series
+12V
Inner
circuit
5.4
0V
(R)
Graphic/
Logic
Panels
(T)
Software
+12V
(Q)
Stepper Motors
& Drivers
& Controllers
(S)
Field
Network
Devices
Contact input
FXS Series
Brown
(O)
Sensor
Controllers
5.4
0V
Solid-state input (Standard sensor: PNP output type sensor)
Brown
+12V
0V
(NPN open
collector output)
Input logic: Voltage (PNP) input
Sensor
(N)
Display
Units
FXS Series
+12V
Blue
0V
CP1, CP2 (INHIBIT), RESET input
(L)
Panel
Meters
Inner
circuit
5.4
0V
Please select the counting
speed as 1cps or 30cps
when it is used for counter.
J-43
FXS Series
Input Logic Selection
Select NPN (No-voltage input) (Factory default)
NPN
Select PNP (Voltage input)
PNP
NPN
PNP
Please be sure to turn OFF the power before changing input logic.
Input & Output Connections
In case of operating the load by external
power supply
External power
In case of operating the load by power supply
of the sensor
(-) Constant-
Load1
Brown
Black
Blue
6 7 8
6 7 8
9 10
CP1 CP2 +12V 0V RESET
(INHIBIT)
12
12
Load2
3 4 5
1 2
Power supply
for the load
- +
SOURCE
voltage
Load1
(+) circuit
9 10
CP1 CP2 +12V 0V RESET
(INHIBIT)
1 2
Power supply
for the load
3 4 5
- +
SOURCE
Load2
The capacity of Load1 must not be exceed Max. 30VDC,
Max. 100mA of the switching capacity of the transistor.
Please do not supply the reverse polarity voltage.
Please connect the surge absorber (Diode) at both
terminals of Load1, in case of using the inductive load.
(Relay, etc.)
Please select proper capacity of load, because total
current consumption should not be exceed current
capacity. (Max. 50mA )
Contact capacity: Max. 250VAC 3A
Using 2 counters with one sensor
It is available to use 2 counters with one sensor.
Please connect as the power of sensor is supplied from only one way of counters and design input logic with same way.
Black
Brown
Blue
9 10
CP1 CP2 +12V 0V RESET
(INHIBIT)
CP1 CP2 +12V
(INHIBIT)
9 10
0V RESET
12
1
4
-
J-44
SOURCE
<FX4S>
5
+
SOURCE
<FX5S-I>
Up/Down Counter/Timer
Description Of Inner DIP Switches
Output mode selection
Memory protection (ON/OFF)
Max. counting speed
Counter/Timer
Up/Down mode selection
Count input mode (Counter)
Time setting mode (Timer)
Inner selection switch is changed from 10pin
to 11pin with upgrade of counting speed.
There is no output operation mode in
indication type (FX5S-I) and SW2 selection
switch.
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
(G)
Connectors/
Sockets
1cps
(H)
Temperature
Controllers
Counter
ON
2kcps
6
ON
OFF
(J)
Counters
OFF
Timer
(I)
SSRs / Power
Controllers
30cps
OFF
(D)
Proximity
Sensors
CP1, CP2
ON
(C)
Door/Area
Sensors
(F)
Rotary
Encoders
OFF
Up mode
(B)
Fiber
Optic
Sensors
(E)
Pressure
Sensors
ON
Function
ON
SW1
Down mode
Memory protection
SW1
SW1
Function
ON
Max. counting speed
Counter/Timer selection
SW1
SW2
Function
OFF
OFF
Up/Down mode
SW1
(A)
Photoelectric
Sensors
(K)
Timers
(L)
Panel
Meters
5kcps
(M)
Tacho /
Speed / Pulse
Meters
Disable the memory protection
Enable the memory protection
(N)
Display
Units
(O)
Sensor
Controllers
Setting Function Of Decimal point
Displays the decimal point.
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
RUN mode
If pressing RESET
button for over 3sec. it
advanced to decimal
point setting mode.
Return to RUN mode
When "DP" flashes,
touch RESET button
once.
Set the position of decimal
point using ,
buttons
of digital switch.
It returns to RUN mode
by press RESET button
over 3sec.
Changing the decimal point
(Factory default)
It returns to RUN mode if no RESET button or digital switch is applied for 60sec. in decimal point setting status.
The decimal point setting is not existed in indication type.
J-45
(S)
Field
Network
Devices
(T)
Software
FXS Series
Input Operation Mode (Counter)
Input mode
ON
OFF
Up/Down-A
(Command
input)
Up/Down-B
(Individual
input)
Count
up
mode
Up/Down-C
(Phase
difference
input)
SW1
ON
No-voltage input (NPN)
2 3
OFF
ON
OFF
ON
cp1 H
L
Count
value
Up
(Count
up input)
OFF
Count
value
ON
OFF
Up/Down-D
(Command
input)
Up/Down-E
(Individual
input)
Count
down
mode
Up/Down-F
(Phase
difference
input)
2 3
OFF
2 3
ON
OFF
2 3
OFF
ON
OFF
cp2
H
L
Count
value
cp2
cp1
H
L
cp2
H
L
cp1
H
L
cp2
H
L
Count
value
cp1
H
L
cp2
H
L
Count
value
cp1
n-2 n-1 n-2
n-3
cp1
H
L
cp2
H
L
n-2
n-3 n-2
Count
value
0
n-2
n-3
No counting
n-3
n-1 n-2
cp1 H
L
cp2 H
L
Count
value
0
n-1
n-4 n-5
cp2
H
L
H
L
Count
value
0
Count
value
0
cp1
H
L
cp2
H
L
Count
value
0
cp1
No counting
No counting
0
No counting
H
L
n
n-1 n-2
Count
n-1 n-2
n-3 n-2
value
n-3
0
cp1 H
L
n-1
cp2
cp1
H
L
cp1 H
L
cp2 H
L
n
n-1 n-2
Count
n-2 n-1 n-1 n-2
n-3
n-3
value
0
cp2 H
L
Count
value
0
Count
value
H
L
H
L
Count
value
No counting
cp1 H
L
cp2 H
L
Down
(Count
down input)
cp1 H
L
2 3
No counting
cp2 H
L n
n-1 n-2
Count
n-3
value
0
ON
ON
cp2 H
L
cp1 H
L
Count
value
H
cp2 L
ON
H
L
cp1 H
L
2 3
cp1
cp1
cp2 H
L
OFF
cp1 H
L
cp2 H
L
Count
value
2 3
cp2 H
L
Count
value
2 3
Voltage input (PNP)
cp1 H
L
n n-1
n-2
n-3
n-2
n-1 n-1
n-2 n-3
n-1 n-2
n-3
n-2
n-1
n-4 n-5
No counting
H
L
H
L n
Count
value
0
n-3
No counting
n-3
n n-1
n-2
n-2
cp2
n-1
n-2
n-3
n-4 n-5
n-1
n-2
n-3 n-4
n-5
: Over Min. signal width, : Over 1/2 of Min. signal width. Counting miss by one (1) occurs if the signal width of or is less than min.
signal width.
J-46
Up/Down Counter/Timer
Counting Operation Of Indication Type (Counter)
Up input mode
Down input mode
Up/Down-A, B, C
input mode
(A)
Photoelectric
Sensors
Up/Down-D, E, F
input mode
(B)
Fiber
Optic
Sensors
RESET
RESET
RESET
RESET
+Max.
display
value
+Max.
display
value
+Max.
display
value
+Max.
display
value
(C)
Door/Area
Sensors
-Max.
display
value
0
-Max.
display
value
(D)
Proximity
Sensors
-Max.
display
value
(E)
Pressure
Sensors
Time Operation Of Indication Type (Timer)
Up input mode
(F)
Rotary
Encoders
Down input mode
RESET
RESET
INHIBIT
INHIBIT
+ Max.
time range
+ Max.
time range
(G)
Connectors/
Sockets
(H)
Temperature
Controllers
(I)
SSRs / Power
Controllers
- Max.
time range
(J)
Counters
Time Setting Mode (Timer)
SW1
ON
4digit
5digit
(K)
Timers
99.99sec
9999.9sec
(L)
Panel
Meters
1 2 3
OFF
ON
(M)
Tacho /
Speed / Pulse
Meters
1 2 3
999.9sec
99999sec
OFF
ON
(N)
Display
Units
1 2 3
9999sec
9min 59.99sec
99min 59sec
99min 59.9sec
(O)
Sensor
Controllers
OFF
ON
(P)
Switching
Mode Power
Supplies
1 2 3
OFF
ON
(Q)
Stepper Motors
& Drivers
& Controllers
1 2 3
999.9min
9999.9min
99hour 59min
9hour 59min 59sec
(R)
Graphic/
Logic
Panels
OFF
ON
1 2 3
(S)
Field
Network
Devices
OFF
ON
(T)
Software
1 2 3
999.9hour
999hour 59min
9999hour
9999.9hour
OFF
ON
1 2 3
OFF
J-47
FXS Series
Output Operation Mode (By Internal DIP Switch)
One-shot output (0.05 to 5sec.)
Output mode
(SW2)
F
ON
1 2 3
OFF
N
ON
1 2 3
OFF
C
ON
1 2 3
OFF
R
ON
1 2 3
OFF
K
ON
1 2 3
OFF
P
ON
1 2 3
OFF
Q
ON
1 2 3
OFF
1 2 3
OFF
Up, Up / Down-A, B, C
1 2 3
Output
Output
Reset
Preset
Reset
Preset
Output
Output
Reset
Preset
Reset
Preset
Output
Output
Reset
Preset
Reset
Preset
Output
Output
Reset
Reset
Preset
Preset
Output
Output
Reset
Preset
Reset
Preset
Output
Output
Reset
Preset
Preset
Down mode
Operation after count up
The display value continues until
reset signal is applied then output
is held.
Retained output will be maintained
until reset signal is applied.
Display value and retained output
are maintained until Reset signal
is applied.
The display value returns to reset
start status as soon as display
value is reached to preset value.
The display value is held until
output is OFF then returns to
reset start status.
The display value continues until
reset signal is applied.
The display value is held during
one-shot output time, counting
process is returned to reset start
status as soon as output is ON.
Reset
The display value continues
during one-shot output time.
Output
Down input
Reset
Preset
Reset
Preset
Output
Up, Up / Down-D, E, F
Reset
Preset
Output
Up / Down-D, E, F
Reset
Preset
Reset
Preset
Output
Output
Reset
Preset
Reset
Preset
Output
Output
One-shot output time is set by front TIME adjuster.
J-48
ON
OFF
SW1
Reset
Preset
Up / Down-A, B, C
OFF
ON
Up mode
Up input
Counter
Timer
ON
OFF
Output
ON
SW1
Retained output
Up, UP/Down-A, B, C input
mode -Output is ON when
(Display value)
(Preset value)
Down, UP/Down-D, E, F input
mode-Output is ON when
(Display value) (Zero)
The output turns ON after the
setting time and then turns
OFF after the setting time.
This operation is repeated
sequentially. (Flicker operation)
Up/Down Counter/Timer
Proper Usage
Reset function
(A)
Photoelectric
Sensors
INHIBIT (For timer)
Reset
In case of changing the input mode after supplying the
power, please take external reset or manual reset.
If reset is not executed, the counter will be working
as previous mode.
(INHIBIT)
1
Reset input
(B)
Fiber
Optic
Sensors
SW1
Reset signal width
It is reset perfectly when the reset signal is applied
during min. 20ms regardless of the contact input &
solid-state input.
10
CP1 CP2 +12V 0V
(C)
Door/Area
Sensors
1: PNP input
2: NPN input
(D)
Proximity
Sensors
If SW1 is ON, it becomes INHIBIT. (Time Hold)
When power is applied, it starts to progress and INHIBIT
mode is used to stop the time is under the progress at
the moment.
When SW1 is OFF, timer starts to progress again.
Sensor power
The power 12VDC which is provided to sensor is built in it.
Please use it under Max. 50mADC.
Min. signal width
Time display value
0
(I)
SSRs / Power
Controllers
(Up mode)
Error display
ERR0
(J)
Counters
Error description
Returning method
Zero setting status
Change the setting
value to non zero status
(K)
Timers
When Error is displayed, the output continues OFF state.
There is no Error function in indicator.
1
1
(H)
Temperature
Controllers
Setting value
Error signal
(F)
Rotary
Encoders
(G)
Connectors/
Sockets
INHIBIT
1: In case of a contact reset, it is reset perfectly if the ON
time of reset signal is applied during min. 20ms even
though a chattering occurs.
2: It can be input the signal of CP1, CP2 after min.50ms
from closing time of reset signal.
(E)
Pressure
Sensors
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
1: Please make duty ratio (ON/OFF ) 1:1
1cps: Min. 500ms
2: Min. signal width 30cps: Min. 16.7ms
2kcps: Min. 0.25ms
5kcps: Min. 0.1ms
Max. counting speed
This is a response speed per 1 sec. when the duty ratio
(ON:OFF) of input signal is 1:1.
If the duty ratio is not 1:1, the width between ON and OFF
should be over min. signal width and the response speed
will getting slower against input signal. And one of ON width
and OFF width is under min. signal width, this product may
not respond.
Ta Tb
3Ta
Width of Ta (ON)and Tb (OFF)
must be larger than Min. signal
width.
Max. counting speed is 1/2 value
of rated spec. when duty ratio is
1:3.
It can not respond if it is smaller
than min. signal width (Ta).
(O)
Sensor
Controllers
Power
The inner circuit voltage starts to rise up for the first 100ms
after power on, the input may not work at this time. And
also the inner circuit voltage drops down for the last 500ms
after power off, the input may not work at this time.
Power
ON
OFF
100
The unstable time
against the input signal
500
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
Case & DIP switch detachment
(T)
Software
Push a lock part to front direction and widen it
simultaneously.
Please be careful of the injury caused by tools.
J-49