1
Level:
Name
Reference level
Maximum cracking
Exposure
: Standard Level
: --: 0,30 (mm)
: XC1
Concrete creep coefficient
: = 2,75-2,75
cement class
:N
Concrete age (loading moment)
: 28 (days)
Concrete age
: 50 (years)
Structure class
: S3
Quality assurance system (4.4.1.3(3); A.2.1(1))
Fire resistance class
: no requirements
Beam: Beam1
2.1
Number: 1
Material properties:
Concrete
C25/30
fck = 25,00 (MPa)
Rectangular stress distribution [3.1.7(3)]
2501,36 (kG/m3)
16,0 (mm)
B500B fyk = 500,00 (MPa)
Horizontal branch of the stress-strain
Density
:
Aggregate size
:
Longitudinal reinforcement: :
diagram
Ductility class : B
Transversal reinforcement:
2.2
B500B fyk = 500,00 (MPa)
Geometry:
2.2.1
Span
Position
L.supp.
(m)
6,20
L
(m)
0,40
R.supp.
(m)
P1
Span 0,40
Span length: Lo = 6,60 (m)
Section from 0,00 to 4,70 (m)
30,0 x 60,0 (cm)
without left slab
without right slab
30,0 x 60,0, Offset (+ up, - down): 0,0 x +0,0 (cm)
without left slab
without right slab
Section from 4,70 to 6,20 (m)
30,0 x 45,0, Offset (+ up, - down): 0,0 x +30,0 (cm)
without left slab
without right slab
2.3
Calculation options:
Regulation of combinations
: EN 1990:2002
Calculations according to
Seismic dispositions
Precast beam
Cover
: EN 1992-1-1:2004 AC:2008
: No requirements
: no
: bottom
c = 3,0 (cm)
: side
c1= 3,0 (cm)
: top
c2= 3,0 (cm)
: Cdev = 0,0(cm), Cdur = 0,0(cm)
: long-term or cyclic load
: strut inclination
Cover deviations
Coefficient 2 =0.50
Method of shear calculations
2.4
Loads:
2.4.1 Continuous:
Nature
self-weight
uniform
dead load
1
dead load(Structural) top
Live(Category A)
top
-
uniform
Pos.
Span f
Type
X0
Pz0
(m)
1,35
X1
(kN/m)
-
Pz1
(m)
21,56
X2
(kN/m)
-
Pz2
(m)
-
X3
(kN/m) (m)
-
1,50
9,85
1,35
f - load factor
2.5
Calculation results:
The quantity of longitudinal reinforcement has been augmented due to
perpendicular cracks
No. Type
1. M [kN*m]
State
SLS
Span
1
x(m) Value
4.82 162.49
Capacity
143.82
n* - Safety factor
2.5.1
Reactions
Support V1
Case
WALL1
WALL2
LL1
Fx
(kN)
-
Fz
(kN)
13,58
71,15
32,51
Mx
(kN*m)
-
My
(kN*m)
0,00
-0,00
0,00
Fx
(kN)
-
Fz
(kN)
13,58
71,15
32,51
Mx
(kN*m)
-
My
(kN*m)
0,00
0,00
0,00
Support V2
Case
WALL1
WALL2
LL1
2.5.2
Span
P1
Internal forces in ULS
Mt max.
(kN*m)
269,19
Mt min.
(kN*m)
-0,00
Ml
(kN*m)
65,05
Mr
(kN*m)
56,13
Ql
(kN)
153,26
Qr
(kN)
-153,26
n*
0.89
-600
[kN*m]
-400
-200
0
200
400
600
[m]
800
0
Bending Moment ULS:
1
M
Mr
2
Mt
Mc
250
200
[kN]
150
100
50
0
-50
-100
-150
-200
-250
[m]
0
Shear Force ULS:
1
V
2.5.3
Span
P1
Vr
2
Vc(stirrups)
Vc(total)
Internal forces in SLS
Mt max.
(kN*m)
193,44
Mt min.
(kN*m)
0,00
Ml
(kN*m)
-29,02
Mr
(kN*m)
-29,02
Ql
(kN)
110,13
Qr
(kN)
-110,13
-400
[kN*m]
-300
-200
-100
0
100
200
300
400
[m]
0
Bending Moment SLS:
2
M_r
Mr_r
3
Mc_r
Mc_qp
M_qp
Mr_qp
150
[kN]
100
50
0
-50
-100
[m]
-150
0
Shear Force SLS:
1
V_r
2
V_qp
Vr_r
Vr_qp
0.6
0.4
[0.1%]
0.2
0
-0.2
-0.4
-0.6
-0.8
-1
-1.2
-1.4
-1.6
[m]
0
Strains:
1
At
Ac
100
[MPa]
50
0
-50
-100
-150
-200
-250
-300
[m]
0
Stresses:
1
Ats
Acs
2.5.4
Span
P1
Bs
Required reinforcement area
Span (cm2)
bottom top
40,09
0,00
Left support (cm2)
bottom top
2,62
1,61
Right support (cm2)
bottom top
3,16
2,25
60
[cm2]
40
20
0
20
40
60
[m]
80
0
1
Reinforcement Area for Bending:
Abt
2
Abr
3
Ades
Abmin
Aver_gross
20
[cm2/m]
15
10
5
0
5
10
15
20
[m]
0
1
Reinforcement Area for Shear:
2
Ast_strut
Ast
3
AsHang
Asr
2.5.5 Deflection and cracking
Total due to quasi-permanent combination
Allowable due to quasi-permanent combination
Deflection increment from the quasi-permanent load combination after erecting a structure.
Admissible deflection increment from the quasi-permanent load combination after
erecting a structure.
wk
Span
P1
2.6
- width of perpendicular cracks
(cm)
1,5
(cm)
2,6
(cm)
0,5
(cm)
0,0
(mm)
0,2
Theoretical results - detailed results:
2.6.1
P1 : Span from 0,40 to 6,60 (m)
Abscissa
(m)
0,40
0,86
1,52
2,18
2,84
3,50
4,16
4,82
5,48
6,14
6,60
ULS
M max.
(kN*m)
65,05
124,66
192,10
238,01
262,38
269,19
262,38
238,01
187,15
117,72
56,13
M min.
(kN*m)
-40,38
-21,33
-0,00
-0,00
-0,00
0,00
-0,00
-0,00
-0,00
-16,00
-40,38
SLS
M max.
(kN*m)
21,10
69,64
123,80
162,49
185,70
193,44
185,70
162,49
123,80
69,64
21,10
Abscissa
ULS
V max.
SLS
V max.
afp
M min.
(kN*m)
-29,02
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
-29,02
A bottom
(cm2)
2,62
5,20
8,20
10,35
11,52
11,85
11,52
40,09
30,27
6,99
3,16
A top
(cm2)
1,61
0,86
0,00
0,00
0,00
0,00
0,00
40,44
18,93
0,89
2,25
A compressive
(cm2)
0,00
0,00
0,00
0,00
0,00
0,00
0,00
40,44
18,93
0,00
0,00
wk
(m)
0,40
0,86
1,52
2,18
2,84
3,50
4,16
4,82
5,48
6,14
6,60
2.7
(kN)
153,26
130,51
97,89
65,26
32,63
-0,00
-32,63
-65,26
-97,89
-130,51
-153,26
(kN)
110,13
93,79
70,34
46,89
23,45
-0,00
-23,45
-46,89
-70,34
-93,79
-110,13
(mm)
0,0
0,0
0,1
0,1
0,1
0,2
0,2
0,2
0,1
0,0
0,0
Reinforcement:
2.7.1
P1 : Span from 0,40 to 6,60 (m)
Longitudinal reinforcement:
bottom (B500B)
5
5
3
l = 5,01
l = 3,71
l = 4,14
from 0,06
from 3,19
from 5,06
assembling (top) (B500B)
2 12
l = 4,02
from 0,83
support (B500B)
5 12
l = 1,90
from 0,03
5 25
l = 3,55
from 3,15
5 12
l = 1,84
from 5,13
2 25
l = 5,86
from 3,17
25
25
25
to
to
to
5,07
6,90
5,06
to
4,85
to
to
to
to
1,93
6,70
6,97
3,17
Surface reinforcement (B500B):
2
12
l = 4,84
from 0,23
to
5,07
Transversal reinforcement:
main (B500B)
stirrups
30
e=
18
e=
2
e=
8
l = 1,69
1*0,05 + 1*0,06 + 12*0,12 + 12*0,20 + 3*0,18 + 1*0,10 (m)
8
l = 1,39
1*4,79 + 11*0,10 + 6*0,05 (m)
12
l = 4,84
1*-0,17 (m)
pins
30
e=
18
e=
2
e=
8
l = 1,69
1*0,05 + 1*0,06 + 12*0,12 + 12*0,20 + 3*0,18 + 1*0,10 (m)
8
l = 1,39
1*4,79 + 11*0,10 + 6*0,05 (m)
12
l = 4,84
1*-0,17 (m)
Material survey:
Concrete volume
= 1,21 (m3)
Formwork = 10,34 (m2)
Steel B500B
Total weight
= 391,63 (kG)
Density
= 323,53 (kG/m3)
Average diameter = 16,1 (mm)
Survey according to diameters:
Diameter Length
Weight
NumberTotal weight
(mm)
8
8
12
12
12
12
25
25
25
25
25
(m)
1,39
1,69
1,84
1,90
4,02
4,84
3,55
3,71
4,14
5,01
5,86
(kG)
0,55
0,67
1,63
1,69
3,57
4,30
13,67
14,29
15,95
19,32
22,60
(No.)
18
30
5
5
2
2
5
5
3
5
2
(kG)
9,84
19,95
8,17
8,46
7,14
8,60
68,36
71,47
47,84
96,62
45,19