0% found this document useful (0 votes)
100 views4 pages

EGS2000 Size 3 Actuator Specs Manual

This document provides technical specifications for the Size 3 actuator component of an Electronic Governor System (EGS2000), including its mechanical, electrical, and input/output specifications. It describes the dimensions, weights, voltage requirements, and operating ranges for the Size 3 power unit, control unit, actuator, tachometer pickups, and scavenge air pressure transducer. Diagrams and drawings referenced provide additional details on part outlines.

Uploaded by

nitin9860
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
100 views4 pages

EGS2000 Size 3 Actuator Specs Manual

This document provides technical specifications for the Size 3 actuator component of an Electronic Governor System (EGS2000), including its mechanical, electrical, and input/output specifications. It describes the dimensions, weights, voltage requirements, and operating ranges for the Size 3 power unit, control unit, actuator, tachometer pickups, and scavenge air pressure transducer. Diagrams and drawings referenced provide additional details on part outlines.

Uploaded by

nitin9860
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

EGS2000 version 4 - User Manual A0-2 of 5

App. A. Technical Specification for SIZE 3 actuator 2001.05.14

Appendix A - (Size 3).

Electronic Governor System EGS2000.

Technical Specification - Size 3.

This appendix comprises the Technical Specification and outline drawings with the actuator
size relevant for your installation.

The contents is:

1. Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-3


1.1 Power Unit Size 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-3
1.2 Control Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-3
1.3 Actuator Specifications Size 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-3
1.4 Tacho Pickups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-3
1.5 Scavenge Air Pressure Transducer . . . . . . . . . . . . . . . . . . . . . . . . . . A0-4

2. Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-4


2.1 Power Unit Size 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-4
2.2 Control Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-4
2.3 Actuator Specifications Size 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-5
2.4 Tacho System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-5
2.5 Scavenge Air Pressure Transducer . . . . . . . . . . . . . . . . . . . . . . . . . . A0-5

3. Outline Drawings.

Power Unit Outline 960.140.195

Control Unit Outline 960.170.192

Actuator Outline 960.140.497

Typical Arrangement of Tacho


Pickups on MAN B&W Engine 960.170.502
Adjustment of Tacho Pickups 960.170.513

Scavenge Air Pressure Transmitter 083.198.004

960.200.561
EGS2000 version 4 - User Manual A0-3 of 5
App. A. Technical Specification for SIZE 3 actuator 2001.05.14

2. Mechanical Specifications.
2.2 Power Unit Size 3.

Dimensions (MAX) Width 800 mm


See outline drawing: 960.140.195 Height 500 mm
Depth 300 mm
Weight, Size 3 60 Kg.

2.4 Control Unit.

Dimensions Width 288 mm


Height 144 mm
Depth 34 mm
Weight 1.6 Kg

2.6 Actuator Specifications Size 3.

Actuator Dimensions (MAX) Diam 240 mm


Outline: Drawing 960.140.497 Length 551 mm
Weight, Size 3 35 Kg

Output Control Force, continuous rating 1400 N


Output Force, acceleration 2150 N
Full stroke time (95 to 10%) with
full fuel rack load 1.8 kgm and 950 N 0.24 s

2.8 Tacho Pickups.

Tacho Pickup Dimensions (MAX) Diam: M18 x 1


Outline: Drawing 900.276.348 Length 84 mm
Weight 0.1 Kg
Length of cable 5m

Distance between sensors 1/2 Tooth Width


See outline drawing 960.170.513
Distance from sensor face to tooth 1 - 4 mm

Max speed for system 1000 tooth/s


Note that all pickups are identical types.

960.200.561
EGS2000 version 4 - User Manual A0-4 of 5
App. A. Technical Specification for SIZE 3 actuator 2001.05.14

2.10 Scavenge Air Pressure Transducer.

Scavenge Air Transducer Dimensions(MAX) Width 116 mm


Outline: Drawing 083.198.004 Height 120 mm
Depth 71 mm
Weight 1 kg

Range 0 - 4 Bar

4. Electrical Specifications.
Terminals used for connections to the EGS2000 (apart from those used for AC mains
input voltage) are capable of accepting wires of 1.5 [Link] in cross-section.
Terminals used for connection of AC mains input voltage to the Power Unit are capable
of accepting wires of 4 [Link] in cross-section.

4.2 Power Unit Size 3.

Input AC Mains voltage 380/440 V AC 3-phase.


Input AC Mains current (Size 3) 2,5 A max cont, 4 A peak

Input supply voltage 24 V DC 30 % incl. rip-


ple
Input supply current (MAX) 6 A.

Max operating temperature 0 - +55 C

Max storage temperature -10 - +70 C

4.4 Control Unit.

Input supply voltage 24 V DC 30% incl. rip-


ple.
Input supply current 1 A.

Communications format RS-485

Max cable communicating distance to Power Unit 200 m.

Max operating temperature 0 - +55 C

960.200.561
EGS2000 version 4 - User Manual A0-5 of 5
App. A. Technical Specification for SIZE 3 actuator 2001.05.14

Max storage temperature -10 - +70 C

Input supply originates from EGS2000 Power Unit.

4.6 Actuator Specifications Size 3.

Input supply voltage 1 150 V AC 3-phase


Input current (Size 3) 6 A at continuous rating,
10 A peak

Input supply voltage 2 24 V DC 30%


Input supply current 2 (MAX) 1A

Max length of cable between actuator and Power Unit 50 m

The actuator supply originates from EGS2000 Power Unit

4.8 Tacho System.

Output (Open Collector Semiconductor) 0 / 24 V DC

Input supply voltage 24 V DC 30%


Input supply current (Max) 20 mA

Input supply originates from EGS2000 Power Unit

4.10 Scavenge Air Pressure Transducer.

Input supply voltage 24 V DC 30%


Input supply current (MAX) 20 mA.

Input pressure range 0 - 4 Bar


Output signal range 4 - 20 mA

Input supply originates from EGS2000 Power Unit

960.200.561