EGS2000 version 4 - User Manual A0-2 of 5
App. A. Technical Specification for SIZE 3 actuator 2001.05.14
Appendix A - (Size 3).
Electronic Governor System EGS2000.
Technical Specification - Size 3.
This appendix comprises the Technical Specification and outline drawings with the actuator
size relevant for your installation.
The contents is:
1. Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-3
1.1 Power Unit Size 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-3
1.2 Control Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-3
1.3 Actuator Specifications Size 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-3
1.4 Tacho Pickups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-3
1.5 Scavenge Air Pressure Transducer . . . . . . . . . . . . . . . . . . . . . . . . . . A0-4
2. Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-4
2.1 Power Unit Size 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-4
2.2 Control Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-4
2.3 Actuator Specifications Size 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-5
2.4 Tacho System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A0-5
2.5 Scavenge Air Pressure Transducer . . . . . . . . . . . . . . . . . . . . . . . . . . A0-5
3. Outline Drawings.
Power Unit Outline 960.140.195
Control Unit Outline 960.170.192
Actuator Outline 960.140.497
Typical Arrangement of Tacho
Pickups on MAN B&W Engine 960.170.502
Adjustment of Tacho Pickups 960.170.513
Scavenge Air Pressure Transmitter 083.198.004
960.200.561
EGS2000 version 4 - User Manual A0-3 of 5
App. A. Technical Specification for SIZE 3 actuator 2001.05.14
2. Mechanical Specifications.
2.2 Power Unit Size 3.
Dimensions (MAX) Width 800 mm
See outline drawing: 960.140.195 Height 500 mm
Depth 300 mm
Weight, Size 3 60 Kg.
2.4 Control Unit.
Dimensions Width 288 mm
Height 144 mm
Depth 34 mm
Weight 1.6 Kg
2.6 Actuator Specifications Size 3.
Actuator Dimensions (MAX) Diam 240 mm
Outline: Drawing 960.140.497 Length 551 mm
Weight, Size 3 35 Kg
Output Control Force, continuous rating 1400 N
Output Force, acceleration 2150 N
Full stroke time (95 to 10%) with
full fuel rack load 1.8 kgm and 950 N 0.24 s
2.8 Tacho Pickups.
Tacho Pickup Dimensions (MAX) Diam: M18 x 1
Outline: Drawing 900.276.348 Length 84 mm
Weight 0.1 Kg
Length of cable 5m
Distance between sensors 1/2 Tooth Width
See outline drawing 960.170.513
Distance from sensor face to tooth 1 - 4 mm
Max speed for system 1000 tooth/s
Note that all pickups are identical types.
960.200.561
EGS2000 version 4 - User Manual A0-4 of 5
App. A. Technical Specification for SIZE 3 actuator 2001.05.14
2.10 Scavenge Air Pressure Transducer.
Scavenge Air Transducer Dimensions(MAX) Width 116 mm
Outline: Drawing 083.198.004 Height 120 mm
Depth 71 mm
Weight 1 kg
Range 0 - 4 Bar
4. Electrical Specifications.
Terminals used for connections to the EGS2000 (apart from those used for AC mains
input voltage) are capable of accepting wires of 1.5 [Link] in cross-section.
Terminals used for connection of AC mains input voltage to the Power Unit are capable
of accepting wires of 4 [Link] in cross-section.
4.2 Power Unit Size 3.
Input AC Mains voltage 380/440 V AC 3-phase.
Input AC Mains current (Size 3) 2,5 A max cont, 4 A peak
Input supply voltage 24 V DC 30 % incl. rip-
ple
Input supply current (MAX) 6 A.
Max operating temperature 0 - +55 C
Max storage temperature -10 - +70 C
4.4 Control Unit.
Input supply voltage 24 V DC 30% incl. rip-
ple.
Input supply current 1 A.
Communications format RS-485
Max cable communicating distance to Power Unit 200 m.
Max operating temperature 0 - +55 C
960.200.561
EGS2000 version 4 - User Manual A0-5 of 5
App. A. Technical Specification for SIZE 3 actuator 2001.05.14
Max storage temperature -10 - +70 C
Input supply originates from EGS2000 Power Unit.
4.6 Actuator Specifications Size 3.
Input supply voltage 1 150 V AC 3-phase
Input current (Size 3) 6 A at continuous rating,
10 A peak
Input supply voltage 2 24 V DC 30%
Input supply current 2 (MAX) 1A
Max length of cable between actuator and Power Unit 50 m
The actuator supply originates from EGS2000 Power Unit
4.8 Tacho System.
Output (Open Collector Semiconductor) 0 / 24 V DC
Input supply voltage 24 V DC 30%
Input supply current (Max) 20 mA
Input supply originates from EGS2000 Power Unit
4.10 Scavenge Air Pressure Transducer.
Input supply voltage 24 V DC 30%
Input supply current (MAX) 20 mA.
Input pressure range 0 - 4 Bar
Output signal range 4 - 20 mA
Input supply originates from EGS2000 Power Unit
960.200.561