The document contains information about various plant items in an industrial process, including storage tanks, pumps, heat exchangers, scrubbers, and columns. It lists the item number, description, materials of construction, capacities, heat transfer areas, dimensions, operating temperatures and pressures, design pressures, absorbed power, and heat loads for each item. It also includes notes about discrepancies between the process flow diagram and simulation.

Uploaded by

Derek Dennis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
340 views2 pages

Area 200 PFD. in Proforma v2

The document contains information about various plant items in an industrial process, including storage tanks, pumps, heat exchangers, scrubbers, and columns. It lists the item number, description, materials of construction, capacities, heat transfer areas, dimensions, operating temperatures and pressures, design pressures, absorbed power, and heat loads for each item. It also includes notes about discrepancies between the process flow diagram and simulation.

Uploaded by

Derek Dennis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Plant Item No.

T-201 P-201 - E-201 C-201 P-203 - - - E-205 - C-202 - - Legend


Caustic s. Caustic s. - Caustic s. Caustic s. Recycle - - - Process s. - Chill water - -
Description storage pump cooler scrubber pump cooler scrubber Stream
100 PAH
Number Alarm
No. Required 1 1 - 1 1 1 - - - 1 - 1 - -
Matl. Of Constr. Mild steel Cast iron - Copper Mild steel Cast iron - - - Copper - Carb steel - -
Control Element
Capacity (m3) 428.7 N/A - 3.517 - - - - 6.765 - - Relief to
P(I)C (I Indicator)
Heat Trans. Area (m2) N/A N/A - 4.819 N/A N/A - - - 31.87 - N/A - - System
Height: - Height: - - - - Height: - - RTS
9.900 5.361 10.31 N
Overall Dimension (m) Utility Code Relief to
Diameter: Diameter: Diameter:
7.425 0.9140 0.9140 Atmosphere
Number of Utility RTA
Operating Temp. (C) 20 20 - 45 45 32 - - - 126 - 44 - - 2-1
Stream
Operating Press. (bar) 4.4 6.0 - 6.0 1.8 6.0 - - - 1.5 - 1.5 - -
Design Press (bar) 4.8 6.5 - 6.5 2.0 6.5 - - - 1.8 - 1.7 - - cxcxczxcvxzvcvxcv
Absorbed Power (kW) N/A 0.5802 - N/A N/A 0.8517 - - - N/A - N/A - - Transmitter
Heat Load (kW) N/A N/A - 23.54 N/A N/A - - - 541.53 - N/A - - TT

80 C Stream Temperature
4.2 bara Stream Pressure

Service Identification Material Abbreviation


Code Service Code Material
N Nitrogen
NG Natural Gas
HP High Pressure Steam
LP Low Pressure Steam
C Condensate
CW Cooling Water
IFW Industrial Fresh Water
BFW Boiler Feed Water
WW Waste Water
E Electricity
Process Notes

There is no pressure drop across heat exchanger E-205. In


reality there should be a pressure drop of 0.2 bar.

Heat exchanger E-201 and pump P-203 should be the other


way around.

Pump P-201 is not in the simulation but is present on the PFD


because Chemcad does not account for feed flow pressure.

Calculated/Drawn By: Vlad Moraru

Date: 15/04/2017 Sheet 1 of 2


Plant section AREA 200
Plant CM-1
Works
University Of Surrey
Department Of Chemical and Process
Engineering
Process Flow sheet / Flow Diagram
Project No. Ser. No. Rev.
Plant Item No. P-202 - E-202 - P-204 C-203 - - E-204 P-205 E-203 D-201 - - Legend
Column - Column - Bottoms Methanol - - Column Reflux Column Reflux - -
Description feed pump preheat pump column reboiler pump condenser drum Stream
100 PAH
Number Alarm
No. Required 1 - 1 - 1 1 - - 1 1 1 1 - -
Matl. Of Constr. Cast iron - Copper - Cast iron Mild steel - - Copper Cast iron Copper Mild steel - -
Control Element
Capacity (m3) - - 12.96 - - 1.158 - - Relief to
P(I)C (I Indicator)
Heat Trans. Area (m2) N/A - 99.97 - N/A N/A - - 35.69 N/A 25.13 N/A - - System
- - Height: - - Length: - - RTS
44.38 2.368 N
Overall Dimension (m) Utility Code Relief to
Diameter: Diameter:
0.6098 0.789 Atmosphere
Number of Utility RTA
Operating Temp. (C) 66 - 112 - 122 112 - - 126 74 86 86 - - 2-1
Stream
Operating Press. (bar) 2.1 - 2.1 - 2.5 2 - - 2.0 2.9 1.7 1.7 - -
Design Press (Bar) 2.5 - 2.5 - 3.0 2.2 - - 2.4 3.5 2.0 2.0 - - cxcxczxcvxzvcvxcv
Absorbed Power (kW) 1.251 - N/A - 0.1594 N/A - - N/A 0.2229 N/A N/A - - Transmitter
Heat Load (kW) N/A - 282.7 - N/A N/A - - 968.1 N/A 910.9 N/A - - TT

80 C Stream Temperature
4.2 bara Stream Pressure

Service Identification Material Abbreviation


Code Service Code Material
N Nitrogen
NG Natural Gas
HP High Pressure Steam
LP Low Pressure Steam
C Condensate
CW Cooling Water
IFW Industrial Fresh Water
BFW Boiler Feed Water
WW Waste Water
E Electricity
Process Notes

Calculated/Drawn By: Vlad Moraru

Date: 15/04/2017 Sheet 2 of 2


Plant section AREA 200
Plant CM-1
Works
University Of Surrey
Department Of Chemical and Process
Engineering
Process Flow sheet / Flow Diagram
Project No. Ser. No. Rev.