ROTODYNE ENGINEERING SERVICES PVT.
LTD DT: 09-5-2014
INSPECTION REPORT
REPORT
ON
MAJOR OVERHAULING
OF
SIEMENS MAKE TURBINE GG 26/25 - 2 type
M/S. IFFCO , PARADEEP
ODISSA
APRIL 2014
M/S ROTODYNE ENGINEERING SERVICES PVT LTD
Rotodyne House 9 & 10, Annapurna Enclave
[Link] to BSNL Office, Chandanagar, Hyderabad-500 050
PH NO: 040-3032362/66, FAX: 040-3034508
E-MAIL:admin@[Link]
ROTODYNE ENGINEERING SERVICES [Link] DT: 09-5-2014
INSPECTION REPORT
INDEX
Page no.
I. TECHNICAL DATA 1
II. TECHNICAL SPECIFICATIONS 2
III. INTRODUCTION OF OVER HAUL 3
IV. BRIEF HISTORY 6
V. ASSEMBLY PROTOCOL ON MAJOR OVER HAUL 8
TURBINE
1.00 BEARING CLEARANCES 8
2.00 OIL GLAND CLEARANCES 10
3.00 ROTOR SETTING DIMENSIONS 11
4.00 CENTERING READINGS 12
5.00 ROTOR FLOAT AND DISTANCE B/W ROTORS 13
6.00 ALLIGNMENT READINGS 16
7.00 ROTOR RUNOUTS 20
8.00 STEAM FLOW PATH CLEARANCES 21
8.01 AXIAL CLEARANCES 21
8.02 RADIAL CLEARANCES 24
9.00 FINAL THERMAL GAPS OF DIAPHRAGMS 25
10.00 SAFETY SYSTEM 26
11.00 SPARE CONSUMED 34
12.00 SPARES RECOMMENDED 34
VI. SUMMARY REPORT 35