0% found this document useful (0 votes)
3K views7 pages

Hume Pipe Design and Discharge Calculations

This document contains calculations for designing culverts for three locations along a road construction project. It determines the hydraulic discharge using Dickens' formula based on the catchment area, then designs culverts using 1.2 meter diameter pipes. For each location, it calculates the required waterway, number of pipes needed based on the pipe diameter, and proposes 1 row of 1.2 meter diameter NP-4 pipes to meet the discharge requirement.

Uploaded by

fevahe756
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3K views7 pages

Hume Pipe Design and Discharge Calculations

This document contains calculations for designing culverts for three locations along a road construction project. It determines the hydraulic discharge using Dickens' formula based on the catchment area, then designs culverts using 1.2 meter diameter pipes. For each location, it calculates the required waterway, number of pipes needed based on the pipe diameter, and proposes 1 row of 1.2 meter diameter NP-4 pipes to meet the discharge requirement.

Uploaded by

fevahe756
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
  • Hydraulic Discharge Calculation for Km 8+360
  • Hydraulic Discharge Calculation for Km 10+752
  • Hydraulic Discharge Calculation for Km 12+225
  • Hydraulic Discharge Calculation for Km 13+260
  • Hydraulic Discharge Calculation for Km 16+800
  • Hydraulic Discharge Calculation for Km 18+300
  • Hydraulic Discharge Calculation for Km 19+430

CALCULATION OF HYDRAULIC DISCHARGE AND DESIGN OF OPENING

Road Name : Construction of Rajegaon-Kirnapur-Lanji-Amgaon Road - 57.640 Km

1 Chainage of C.D.:- 8+630

2 Description of catchments: 0.05 [Link] Acre. 12.35

3 Hight of fill permitted :- 0.6 Mtr Hectares 10

4 Pipe Diameter proposed:- 1.2 Mtr No 1


Catchment Diameter of
Area pipe(mm)
(Hectares)
Up to 10Hect 1000 Single
PROCEDURE ADOPTED: - Row
10 to 20 1200 (2 Row)
A- For finding discharge dickens's formula is adopted. (For M.P. Plain 20 to 50 1000 or1200
Terrain) (2to3R)
50 to 60 1000 or1200
B- For M.P. Terrain Coefficient of discharge =14 to 19 (4R)
As per S.P.-20
Q = CM¾
= 17*( 0.05 )¾
= 1.797531148 cum/sec
PROPOSAL :- 1.2 Mtr dia NP-4 Hume pipe is proposed to provide

Length of pipe L= 22.5


For Square entry Ke = 1.107 ( R )^0.5 = 0.86 As per article 32 (22.5e) of IRC SP 13

Kf = 0.00394 L/ R^1.2 = 0.07 Kf as per fig [Link] IRC SP 13

Velocity v =4.43*(H/1+Ke+Kf)^0.5 = 2.47

Area of one pipe A= πd^2/4 = 1.13 Up to 7Hect 1 No


8 to 18 2 No
Discharge by one pipe Q = A*v = 2.79 19 to 32 3 No
33 to 47 4 No
No of pipe required :-
As per This Design
Water way required= 1.79753 / v = 0.7275 Sqm

Area of one 1000mm of pipe= π/4(d) 2


= ¼*3.14*(d)^2= 1.1304 Sqm

No. of pipe required = total water way /area of one pipe


= 0.7275 /0.785 0.6436
No, Say = 1

Hence provide 1 rows of 1.2 Mtr dia NP-4 pipes


CALCULATION OF HYDRAULIC DISCHARGE AND DESIGN OF OPENING

Road Name : Construction of Rajegaon-Kirnapur-Lanji-Amgaon Road - 57.640 Km

1 Chainage of C.D.:- 9+670

2 Description of catchments: 0.069 [Link] Acre. 17.04

3 Hight of fill permitted :- 0.6 Mtr Hectares 10

4 Pipe Diameter proposed:- 1.2 Mtr No 1


Catchment Diameter of
Area pipe(mm)
(Hectares)
Up to 10Hect 1000 Single
PROCEDURE ADOPTED: - Row
10 to 20 1200 (2 Row)
A- For finding discharge dickens's formula is adopted. (For M.P. Plain 20 to 50 1000 or1200
Terrain) (2to3R)
50 to 60 1000 or1200
B- For M.P. Terrain Coefficient of discharge =14 to 19 (4R)
As per S.P.-20
Q = CM¾
= 17*( 0.069 )¾
= 2.288683504 cum/sec
PROPOSAL :- 1.2 Mtr dia NP-4 Hume pipe is proposed to provide

Length of pipe L= 22.5


For Square entry Ke = 1.107 ( R )^0.5 = 0.86 As per article 32 (22.5e) of IRC SP 13

Kf = 0.00394 L/ R^1.2 = 0.07 Kf as per fig [Link] IRC SP 13

Velocity v =4.43*(H/1+Ke+Kf)^0.5 = 2.47

Area of one pipe A= πd^2/4 = 1.13 Up to 7Hect 1 No


8 to 18 2 No
Discharge by one pipe Q = A*v = 2.79 19 to 32 3 No
33 to 47 4 No
No of pipe required :-
As per This Design
Water way required= 2.28868 / v = 0.9263 Sqm

Area of one 1000mm of pipe= π/4(d) 2


= ¼*3.14*(d)^2= 1.1304 Sqm

No. of pipe required = total water way /area of one pipe


= 0.92627 /0.785 0.8194
No, Say = 1

Hence provide 1 rows of 1.2 Mtr dia NP-4 pipes


CALCULATION OF HYDRAULIC DISCHARGE AND DESIGN OF OPENING

Road Name : Construction of Rajegaon-Kirnapur-Lanji-Amgaon Road - 57.640 Km

1 Chainage of C.D.:- 10+750

2 Description of catchments: 0.04 [Link] Acre. 9.88

3 Hight of fill permitted :- 0.6 Mtr Hectares 10

4 Pipe Diameter proposed:- 1.2 Mtr No 1


Catchment Diameter of
Area pipe(mm)
(Hectares)
Up to 10Hect 1000 Single
PROCEDURE ADOPTED: - Row
10 to 20 1200 (2 Row)
A- For finding discharge dickens's formula is adopted. (For M.P. Plain 20 to 50 1000 or1200
Terrain) (2to3R)
50 to 60 1000 or1200
B- For M.P. Terrain Coefficient of discharge =14 to 19 (4R)
As per S.P.-20
Q = CM¾
= 17*( 0.04 )¾
= 1.520526225 cum/sec
PROPOSAL :- 1.2 Mtr dia NP-4 Hume pipe is proposed to provide

Length of pipe L= 22.5


For Square entry Ke = 1.107 ( R )^0.5 = 0.86 As per article 32 (22.5e) of IRC SP 13

Kf = 0.00394 L/ R^1.2 = 0.07 Kf as per fig [Link] IRC SP 13

Velocity v =4.43*(H/1+Ke+Kf)^0.5 = 2.47

Area of one pipe A= πd^2/4 = 1.13 Up to 7Hect 1 No


8 to 18 2 No
Discharge by one pipe Q = A*v = 2.79 19 to 32 3 No
33 to 47 4 No
No of pipe required :-
As per This Design
Water way required= 1.52053 / v = 0.6154 Sqm

Area of one 1000mm of pipe= π/4(d) 2


= ¼*3.14*(d)^2= 1.1304 Sqm

No. of pipe required = total water way /area of one pipe


= 0.61539 /0.785 0.5444
No, Say = 1

Hence provide 1 rows of 1.2 Mtr dia NP-4 pipes


CALCULATION OF HYDRAULIC DISCHARGE AND DESIGN OF OPENING

Road Name : Construction of Rajegaon-Kirnapur-Lanji-Amgaon Road - 57.640 Km

1 Chainage of C.D.:- 13+200

2 Description of catchments: 0.025 [Link] Acre. 6.18

3 Hight of fill permitted :- 0.6 Mtr Hectares 10

4 Pipe Diameter proposed:- 1.2 Mtr No 1


Catchment Diameter of
Area pipe(mm)
(Hectares)
Up to 10Hect 1000 Single
PROCEDURE ADOPTED: - Row
10 to 20 1200 (2 Row)
A- For finding discharge dickens's formula is adopted. (For M.P. Plain 20 to 50 1000 or1200
Terrain) (2to3R)
50 to 60 1000 or1200
B- For M.P. Terrain Coefficient of discharge =14 to 19 (4R)
As per S.P.-20
Q = CM¾
= 17*( 0.025 )¾
= 1.068818415 cum/sec
PROPOSAL :- 1.2 Mtr dia NP-4 Hume pipe is proposed to provide

Length of pipe L= 22.5


For Square entry Ke = 1.107 ( R )^0.5 = 0.86 As per article 32 (22.5e) of IRC SP 13

Kf = 0.00394 L/ R^1.2 = 0.07 Kf as per fig [Link] IRC SP 13

Velocity v =4.43*(H/1+Ke+Kf)^0.5 = 2.47

Area of one pipe A= πd^2/4 = 1.13 Up to 7Hect 1 No


8 to 18 2 No
Discharge by one pipe Q = A*v = 2.79 19 to 32 3 No
33 to 47 4 No
No of pipe required :-
As per This Design
Water way required= 1.06882 / v = 0.4326 Sqm

Area of one 1000mm of pipe= π/4(d) 2


= ¼*3.14*(d)^2= 1.1304 Sqm

No. of pipe required = total water way /area of one pipe


= 0.43257 /0.785 0.3827
No, Say = 1

Hence provide 1 rows of 1.2 Mtr dia NP-4 pipes


CALCULATION OF HYDRAULIC DISCHARGE AND DESIGN OF OPENING

Road Name : Construction of Rajegaon-Kirnapur-Lanji-Amgaon Road - 57.640 Km

1 Chainage of C.D.:- 16+080

2 Description of catchments: 0.038 [Link] Acre. 9.39

3 Hight of fill permitted :- 0.6 Mtr Hectares 10

4 Pipe Diameter proposed:- 1.2 Mtr No 1


Catchment Diameter of
Area pipe(mm)
(Hectares)
Up to 10Hect 1000 Single
PROCEDURE ADOPTED: - Row
10 to 20 1200 (2 Row)
A- For finding discharge dickens's formula is adopted. (For M.P. Plain 20 to 50 1000 or1200
Terrain) (2to3R)
50 to 60 1000 or1200
B- For M.P. Terrain Coefficient of discharge =14 to 19 (4R)
As per S.P.-20
Q = CM¾
= 17*( 0.038 )¾
= 1.463142478 cum/sec
PROPOSAL :- 1.2 Mtr dia NP-4 Hume pipe is proposed to provide

Length of pipe L= 22.5


For Square entry Ke = 1.107 ( R )^0.5 = 0.86 As per article 32 (22.5e) of IRC SP 13

Kf = 0.00394 L/ R^1.2 = 0.07 Kf as per fig [Link] IRC SP 13

Velocity v =4.43*(H/1+Ke+Kf)^0.5 = 2.47

Area of one pipe A= πd^2/4 = 1.13 Up to 7Hect 1 No


8 to 18 2 No
Discharge by one pipe Q = A*v = 2.79 19 to 32 3 No
33 to 47 4 No
No of pipe required :-
As per This Design
Water way required= 1.46314 / v = 0.5922 Sqm

Area of one 1000mm of pipe= π/4(d) 2


= ¼*3.14*(d)^2= 1.1304 Sqm

No. of pipe required = total water way /area of one pipe


= 0.59216 /0.785 0.5239
No, Say = 1

Hence provide 1 rows of 1.2 Mtr dia NP-4 pipes


CALCULATION OF HYDRAULIC DISCHARGE AND DESIGN OF OPENING

Road Name : Construction of Rajegaon-Kirnapur-Lanji-Amgaon Road - 57.640 Km

1 Chainage of C.D.:- 16+100

2 Description of catchments: 0.045 [Link] Acre. 11.12

3 Hight of fill permitted :- 0.6 Mtr Hectares 10

4 Pipe Diameter proposed:- 1.2 Mtr No 1


Catchment Diameter of
Area pipe(mm)
(Hectares)
Up to 10Hect 1000 Single
PROCEDURE ADOPTED: - Row
10 to 20 1200 (2 Row)
A- For finding discharge dickens's formula is adopted. (For M.P. Plain 20 to 50 1000 or1200
Terrain) (2to3R)
50 to 60 1000 or1200
B- For M.P. Terrain Coefficient of discharge =14 to 19 (4R)
As per S.P.-20
Q = CM¾
= 17*( 0.045 )¾
= 1.660956684 cum/sec
PROPOSAL :- 1.2 Mtr dia NP-4 Hume pipe is proposed to provide

Length of pipe L= 22.5


For Square entry Ke = 1.107 ( R )^0.5 = 0.86 As per article 32 (22.5e) of IRC SP 13

Kf = 0.00394 L/ R^1.2 = 0.07 Kf as per fig [Link] IRC SP 13

Velocity v =4.43*(H/1+Ke+Kf)^0.5 = 2.47

Area of one pipe A= πd^2/4 = 1.13 Up to 7Hect 1 No


8 to 18 2 No
Discharge by one pipe Q = A*v = 2.79 19 to 32 3 No
33 to 47 4 No
No of pipe required :-
As per This Design
Water way required= 1.66096 / v = 0.6722 Sqm

Area of one 1000mm of pipe= π/4(d) 2


= ¼*3.14*(d)^2= 1.1304 Sqm

No. of pipe required = total water way /area of one pipe


= 0.67222 /0.785 0.5947
No, Say = 1

Hence provide 1 rows of 1.2 Mtr dia NP-4 pipes


CALCULATION OF HYDRAULIC DISCHARGE AND DESIGN OF OPENING

Road Name : Construction of Rajegaon-Kirnapur-Lanji-Amgaon Road - 57.640 Km

1 Chainage of C.D.:- 18+930

2 Description of catchments: 0.034 [Link] Acre. 8

3 Hight of fill permitted :- 0.6 Mtr Hectares 10

4 Pipe Diameter proposed:- 1.2 Mtr No 1


Catchment Diameter of
Area pipe(mm)
(Hectares)
Up to 10Hect 1000 Single
PROCEDURE ADOPTED: - Row
10 to 20 1200 (2 Row)
A- For finding discharge dickens's formula is adopted. (For M.P. Plain 20 to 50 1000 or1200
Terrain) (2to3R)
50 to 60 1000 or1200
B- For M.P. Terrain Coefficient of discharge =14 to 19 (4R)
As per S.P.-20
Q = CM¾
= 17*( 0.034 )¾
= 1.346040444 cum/sec
PROPOSAL :- 1.2 Mtr dia NP-4 Hume pipe is proposed to provide

Length of pipe L= 22.5


For Square entry Ke = 1.107 ( R )^0.5 = 0.86 As per article 32 (22.5e) of IRC SP 13

Kf = 0.00394 L/ R^1.2 = 0.07 Kf as per fig [Link] IRC SP 13

Velocity v =4.43*(H/1+Ke+Kf)^0.5 = 2.47

Area of one pipe A= πd^2/4 = 1.13 Up to 7Hect 1 No


8 to 18 2 No
Discharge by one pipe Q = A*v = 2.79 19 to 32 3 No
33 to 47 4 No
No of pipe required :-
As per This Design
Water way required= 1.34604 / v = 0.5448 Sqm

Area of one 1000mm of pipe= π/4(d) 2


= ¼*3.14*(d)^2= 1.1304 Sqm

No. of pipe required = total water way /area of one pipe


= 0.54477 /0.785 0.4819
No, Say = 1

Hence provide 1 rows of 1.2 Mtr dia NP-4 pipes

You might also like