Doc.
INS/AH/2017
Page
INSPECTA MIDDLE EAST No.
Page 1 of 2
Rev. 0
INSPECTION AND TEST PLAN
FOR PAINTING
ITP
Owner :
Job No :
Document No:
Revision Date Issued by Checked Approved
Page 1 of 2
Doc. INS/AH/2017
Page
INSPECTA MIDDLE EAST No.
Page 2 of 2
Rev. 0
Act Description of of Q/C method Standard and Acceptance Verifying Cont. Client
No Q/ C Activity specification criteria Dotcom. Q/C Q/C
1 Before Surface Preparation
1.1 visual Free from weld Spec no H M
Steel work spatter, sharp edges
and contamination
1.2 Abrasive Lab analysis ISO 11126- Table3&4 H R
ISO11127 SPX
ASTM D4940
1.3 Oil leakage from compressor White Rag ASTM D4285 Oil free H R
1.4 Pressure at nozzle Hypodermic 7 bar H R
Needle gauge
1.5 Rust grade visual ISO 8501-1,2 H R
1.6 Airless pressure ratio Min 1:45 H R
1.7 Oil and grease Water break test Oil free H M
2 During surface preparation
2.1 Climatic condition Sling hygrometer ISO 8502-4 RH < 85% H R
and thermometer
S.T-D.P.T >3ºC
S.T< 47ºC
3 After Surface preparation
3.1 Preparation grade Visually ISO 8501-1,2 H R
3.2 Anchor Pattern Testex tape ASTM D4417 40-75 MICRONS H R
3.3 Salt contamination Besle test ISO8502-6,9 Max 50 mg/m2 H R
Dust On Substrate Pressure sensitive ISO 8502-3 Rating No-2 H R
tape
Climatic condition Sling hygrometer ISO 8502-4 RH < 85% H R
and thermometer
S.T-D.P. T >3ºC
S. T< 47ºC
4 Paint Application
Wet film thickness Comb gauge ASTM D4414 TDS H R
Dry Film Thickness Eddy current SSPC-PA 2 Specified DFT H W
method
5 Final test
5.1 Bond strength Pull off ASTM D4541 3 MPa H W
5.2 Porosity tests Wet sponge ASTM D 5I62 Min 3 points in m2 H W
INSPECTION CLASSIFICATION MARK –UP CODES
H= Hold Inspection and signature required before further operation can progress
W= Full Witness inspection –physical inspection for compliance, approved
R = Review check reports test sheet etc…for accuracy and authenticity
M= Monitor spot check /inspection for compliance
Page 2 of 2