0% found this document useful (0 votes)
2K views4 pages

Siemens Air-Cooled Generators Sgen-1000A Series: Answers For Energy

Uploaded by

Yussif Nawaf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views4 pages

Siemens Air-Cooled Generators Sgen-1000A Series: Answers For Energy

Uploaded by

Yussif Nawaf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
  • Siemens Air-Cooled Generators Overview
  • Technical Features of Air-Cooled Generators
  • Design Principles and Customer Benefits
  • SGen-1000A Series References

Siemens Air-Cooled Generators

SGen-1000A Series
with ratings from 165 MVA up to 350 MVA

SGen5-1000A at Simmering Power Plant near Vienna, Austria

Siemens offers in its Siemens Generator This generator product line brings together
(SGen™) product line advanced air-cooled, all of the experience gained in the manufac-
two-pole generators, called SGen‑1000A turing of more than 9,000 generators over
­series, with ratings between 165 and the past 100 years, with a combined total
350 MVA for steam and gas turbines. of more than 700 GW of installed capacity.

Answers for energy.


Air-Cooled Generators

1 The complete stator core and winding assembly 5 The aluminium "high-efficiency endplate" acts 7 The stator core is flexibly supported in the
is Global Vacuum Pressure Impregnated (GVPI) as both a mechanical pressure plate for the lam- ­outer casing by spring assemblies. This prevents
with an epoxy-mica (MICALASTIC®) insulation inated stator core and a shield for the magnetic vibration at double rotational frequency from
system that provides uniform electrical insulation field. The design of the generator makes use of impacting the outer casing and thus the foun­
and added mechanical strength materials that reduce eddy-current losses in the dation tabletop
area of the pressure plate
2 The radially direct cooled stator core provides 8 The use of multiple cooling zones in the active
maximum heat transfer capability for the stator 6 The RIGI-FLEX® end-winding support system has part of the generator yields a more uniform
winding with minimum flow resistance for the been in successful operation since the 1980s. temperature profile
overall cooling circuit This well-proven bracing system provides rigidity
9 Collector housing for static excitation system.
to withstand transient fault loads combined
3 Radial path rotor cooling with flow path that Brushless exciters also available
with flexibility to withstand normal operation
provides a uniform flow and temperature distri-
cyclic thermal expansion and contraction, which
bution and reduces field current requirements
occurs during startups and load changes
4 Symmetrical ventilation system uses two
low‑pressure air blowers in conjunction with
a multi-zone stator cooling construction

6 5

9 7

2
Siemens generator design principles, which Customer benefits
have been validated both in the manufacturing
■■ World class efficiency
process and in continuous generator operation,
have been further improved by applying the ■■ Uniform temperature profile for decades
­patents and experience that came to us through of reliable service
acquisition of Westinghouse's Power Generation
■■ Suitable for outdoor installation
Business Unit, with the objective of increasing
the benefits to plant operations. ■■ Simplified installation through use
of a baseframe
The proven modular system makes it possible
■■ Transport dimensions suitable for rail
to produce a wide range of generators by using
transport in most countries
rotors with different diameters as well as different
active body lengths. ■■ Design based on field-proven generator
component designs
The same active generator components are
used in both the air-cooled and hydrogen-cooled
generators. This means that customers who
choose air-cooled generators benefit from the
manu­facturing and operational advances made
with respect to hydrogen-cooled generators.

A design requiring low maintenance in connec-


tion with our worldwide service network guaran-
tees the highest availability.

Technical data

Frequency Model Power factor Apparent power Efficiency Terminal voltage

50 Hz SGen5-1000A 0.8 to 0.9 165 MVA to 350 MVA >98.8 % 10.5 kV to 20 kV

60 Hz SGen6-1000A 0.8 to 0.9 165 MVA to 310 MVA >98.8 % 13.8 kV to 18 kV

Coolant Air-, OAC (Open Air-Cooled) or TEWAC (Totally Enclosed Water to Air-Cooled)

Design In accordance with IEC and ANSI standards

Thermal classification Class F insulation system

Type of enclosure Suitable for outdoor and indoor installation

Excitation Static or brushless

Transport dimensions Suitable for rail transport in most countries

3
SGen-1000A Series Air-Cooled Generators: References

Jebel Ali L2, UAE


Combined-cycle power plant

Performance

Net plant output: 410 MW

Generator Type: SGen5-1000A

Apparent Power: 256 MVA

Simering 1, Austria
Combined-cycle power plant

Performance

Net plant output: 894 MW

Generator Type: SGen5-1000A

Apparent Power: 315 MVA

Ambarli, Turkey
Combined-cycle power plant

Performance

Net plant output: 560 MW

Generator Type: SGen5-1000A

Apparent Power: 350 MVA

For more information please contact


your local Siemens sales representative.

Published by and copyright © 2012: For more information, please contact Fossil Power Generation Division All rights reserved.
Siemens AG our Customer Support Center. Order No. E50001-G210-A183-X-4A00 Trademarks mentioned in this document
are the property of Siemens AG, its affiliates,
Energy Sector Phone: +49 180/524 70 00 Printed in Germany
or their respective owners.
Freyeslebenstrasse 1 Fax: +49 180/524 24 71 Dispo 34802, c4bs No. 7449
91058 Erlangen, Germany (Charges depending on provider) TH 214-120204 432361 DB 08121.0 Subject to change without prior notice.
E-mail: [Link]@[Link] The information in this document contains
Siemens Energy, Inc. Printed on elementary chlorine-free general descriptions of the technical options
available, which may not apply in all cases.
4400 Alafaya Trail bleached paper.
The required technical options should therefore
Orlando, FL 32826-2399, USA be specified in the contract.

[Link]/energy

Answers for energy.
Siemens Air-Cooled Generators 
SGen-1000A Series
with ratings from 165 MVA up to 350 MVA
SGen5-1000A at S
2
Air-Cooled Generators
1 	 The complete stator core and winding assembly 
is Global Vacuum Pressure Impregnated (GVPI) 
with
3
Technical data
Frequency
Model
Power factor
Apparent power
Efficiency
Terminal voltage
50 Hz
SGen5-1000A
0.8 to 0.9
165 MVA
Simering 1, Austria 
Combined-cycle power plant
Performance
Net plant output:
894 MW
Generator Type:
SGen5-1000A