SEPAKAT SETIA PERUNDING SDN BHD (14142-M) JOB NO.
: 33106
TITLE : DESIGN OF BASEMENT WALL TO BS8110 & BS8007 Designer : KKL Date : 11/1/2020
SUBJECT : WALL WITH RAMP AT GRID Q (FROM SUPPORT C TO SUPPORT F) Checker : LKW Date : 11/1/2020
PROJECT : PUTRAJAYA DEVELOPMENT - LOT 2G5 Page No. : Of :
Written by K. L. Kuan, May 2001
DESIGN INFORMATION
Width, b = 1000 mm Support C
Wall Thickness at Support C, H1 = 550 mm 550 mm
Wall Thickness at Support F, H2 = 700 mm
Concrete Cover Thickness, c = 40 mm
Concrete Grade, fcu = 35 N/mm2
Steel Grade, fy = 460 N/mm2 INNER FACE OUTER FACE
Partial Material Factor, gm = 1.25
Allowable Crack Width, w = 0.2 mm Support F
Temperature rise due to hydration of cement, T1 = 35 o
C 700 mm
Temperature fall due to seasonal variation, T2 = 5 o
C
T 1 + T2 = 40 o
C
OUTER FACE @ SUPPORT C
Ultimate Moment at Support C, Mu = 105.0 kNm (per meter strip)
Service Moment at Support C, Ms = 80.0 kNm (per meter strip)
From Design Table to BS8007 (see Table B1), minimum reinforcements are:
T 12 @ 125 c/c As = 904.8 mm2 (per meter strip) or
T 16 @ 225 c/c As = 893.6 mm2 (per meter strip) or
T 20 @ 300 c/c As = 1047.2 mm2 (per meter strip)
Hence, provide T 12 @ 125 c/c As = 904.8 mm2 (per meter strip) where
Ultimate Moment Capacity, Mu(cap) = 173 kNm ==> O.K.!
Service Moment Capacity, Ms(cap) = 151 kNm ==> O.K.!
Ultimate Shear Force at Support C (ULS), Vu = 172.0 kN (per meter strip)
Shear Force at 1d from Support C (ULS), Vd = 134.0 kN (per meter strip)
Effective Depth, d = 504 mm (H1 - c - dia/2)
Shear Stress at 1d from Support C (ULS), vd = 0.2659 N/mm2 (1000*Vd/b/d)
Allowable Maximum Shear Stress, 0.8 fcu1/2 = 4.7329 N/mm2 (but < 5.0 N/mm2)
Allowable Shear Stress, vc = 0.3988 N/mm2 (0.79*(100As/bd)1/3*(400/d)1/4/gm*(fcu/25)1/3)
(but 100As/bd <= 3, 400/d > 1, & fcu <= 40)
Shear Stress Check: vd < 0.8 fcu1/2 or 5.0 ==> O.K.!
vd < vc ==> So Shear Capacity OK !
Thermal & Shrinkage Check:
Wall Thickness = 550 mm
Surface Zone Depth = 250 mm (H/2 but <= 250 mm)
From Design Table to BS8007 (see Table A1),
For T 12 , As(req) = 1206.0 mm2 ==> Not OK !
OUTER FACE @ SUPPORT F
Ultimate Moment at Support F, Mu = 168.0 kNm (per meter strip)
Service Moment at Support F, Ms = 120.0 kNm (per meter strip)
From Design Table to BS8007 (see Table B1), minimum reinforcements are:
T 12 @ 100 c/c As = 1131.0 mm2 (per meter strip) or
T 16 @ 200 c/c As = 1005.3 mm2 (per meter strip) or
T 20 @ 300 c/c As = 1047.2 mm2 (per meter strip)
Hence, provide T 12 @ 100 c/c As = 1131.0 mm2 (per meter strip) where
Ultimate Moment Capacity, Mu(cap) = 281 kNm ==> O.K.!
Page 1 of 6
SEPAKAT SETIA PERUNDING SDN BHD (14142-M) JOB NO. : 33106
TITLE : DESIGN OF BASEMENT WALL TO BS8110 & BS8007 Designer : KKL Date : 11/1/2020
SUBJECT : WALL WITH RAMP AT GRID Q (FROM SUPPORT C TO SUPPORT F) Checker : LKW Date : 11/1/2020
PROJECT : PUTRAJAYA DEVELOPMENT - LOT 2G5 Page No. : Of :
Written by K. L. Kuan, May 2001
Service Moment Capacity, Ms(cap) = 262 kNm ==> O.K.!
Page 2 of 6
SEPAKAT SETIA PERUNDING SDN BHD (14142-M) JOB NO. : 33106
TITLE : DESIGN OF BASEMENT WALL TO BS8110 & BS8007 Designer : KKL Date : 11/1/2020
SUBJECT : WALL WITH RAMP AT GRID Q (FROM SUPPORT C TO SUPPORT F) Checker : LKW Date : 11/1/2020
PROJECT : PUTRAJAYA DEVELOPMENT - LOT 2G5 Page No. : Of :
Written by K. L. Kuan, May 2001
Ultimate Shear Force at Support F (ULS), Vu = 249.0 kN (per meter strip)
Shear Force at 1d from Support F (ULS), Vd = 158.0 kN (per meter strip)
Effective Depth, d = 654 mm (H2 - c - dia/2)
Shear Stress at 1d from Support F (ULS), vd = 0.2416 N/mm2 (1000*Vd/b/d)
Allowable Maximum Shear Stress, 0.8 fcu1/2 = 4.7329 N/mm2 (but < 5.0 N/mm2)
Allowable Shear Stress, vc = 0.3939 N/mm2 (0.79*(100As/bd)1/3*(400/d)1/4/gm*(fcu/25)1/3)
(but 100As/bd <= 3, 400/d > 1, & fcu <= 40)
Shear Stress Check vd < 0.8 fcu1/2 or 5.0 ==> O.K.!
vd < vc ==> So Shear Capacity OK !
Thermal & Shrinkage Check:
Wall Thickness = 700 mm
Surface Zone Depth = 250 mm (H/2 but <= 250 mm)
From Design Table to BS8007 (see Table A1),
For T 12 , As(req) = 1206.0 mm2 ==> Not OK !
INNER FACE @ MIDSPAN
Ultimate Moment at Midspan, Mu = 67.2 kNm (per meter strip)
Service Moment at Midspan, Ms = 48.0 kNm (per meter strip)
From Design Table to BS8007 (see Table B1), minimum reinforcements are:
T 12 @ 125 c/c As = 904.8 mm2 (per meter strip) or
T 16 @ 225 c/c As = 893.6 mm2 (per meter strip) or
T 20 @ 300 c/c As = 1047.2 mm2 (per meter strip)
Hence, provide T 12 @ 125 c/c As = 904.8 mm2 (per meter strip) where
Ultimate Moment Capacity, Mu(cap) = 199 kNm ==> O.K.!
Service Moment Capacity, Ms(cap) = 186 kNm ==> O.K.!
Thermal & Shrinkage Check:
Wall Thickness = 625 mm (H1+H2)/2
Surface Zone Depth = 250 mm (H/2 but <= 250 mm)
From Design Table to BS8007 (see Table A1),
For T 12 , As(req) = 1206.0 mm2 ==> Not OK !
DISTRIBUTION STEEL
Nominal Area of Reinforcement Required, As(req) = 910.0 mm2 (per meter strip) (0.13%bH)
Hence, provide T 16 @ 125 c/c As = 1608.5 mm2 (per meter strip)
Thermal & Shrinkage Check:
Wall Thickness = 700 mm (Max of H1 and H2)
Surface Zone Depth = 250 mm (H/2 but <= 250 mm)
From Design Table to BS8007 (see Table A1),
For T 16 , As(req) = 1608.0 mm2 ==> O.K.!
Page 3 of 6
SEPAKAT SETIA PERUNDING SDN BHD (14142-M) JOB NO. : 33106
TITLE : DESIGN OF BASEMENT WALL TO BS8110 & BS8007 Designer : KKL Date : 11/1/2020
SUBJECT : WALL WITH RAMP AT GRID Q (FROM SUPPORT C TO SUPPORT F) Checker : LKW Date : 11/1/2020
PROJECT : PUTRAJAYA DEVELOPMENT - LOT 2G5 Page No. : Of :
Written by K. L. Kuan, May 2001
Page 4 of 6
How to use this worksheet, please refer to "Design of concrete structures for retaining aqueous liquids" by R. Cheng, published by Thomas Telford 1996
DESIGN TABLE TO BS8007- A1
REINFORCEMENTS REQUIRED FOR CONTROL OF THERMAL AND SHRINKAGE CRACKS (BY IR. T.C. LIM)
Crack width, W= 0.20 mm f =
y
460 N/mm2
Coefficient of thermal expansion, e= 12E-06 ftc/fb = 0.67
T1 = Temperature rise due to hydration of cement
T2 = Temperature fall due to seasonal variation
Minimum reinforcement assumed r = 0.35%bh for high tensile steel
crit
and r = 0.65%bh for mild steel
crit
Bar SURFACE ZONE DEPTH
T1+T2
Dia 250 250 250 250 0 0 0 0 0 0 0 0 0
area of reinforcement in mm 2
12 15 875 875 875 875 0 0 0 0 0 0 0 0 0
12 20 875 875 875 875 0 0 0 0 0 0 0 0 0
12 25 875 875 875 875 0 0 0 0 0 0 0 0 0
12 30 905 905 905 905 0 0 0 0 0 0 0 0 0
12 35 1055 1055 1055 1055 0 0 0 0 0 0 0 0 0
12 40 1206 1206 1206 1206 0 0 0 0 0 0 0 0 0
12 45 1357 1357 1357 1357 0 0 0 0 0 0 0 0 0
12 50 1508 1508 1508 1508 0 0 0 0 0 0 0 0 0
12 55 1658 1658 1658 1658 0 0 0 0 0 0 0 0 0
12 60 1809 1809 1809 1809 0 0 0 0 0 0 0 0 0
12 65 1960 1960 1960 1960 0 0 0 0 0 0 0 0 0
12 70 2111 2111 2111 2111 0 0 0 0 0 0 0 0 0
16 15 875 875 875 875 0 0 0 0 0 0 0 0 0
16 20 875 875 875 875 0 0 0 0 0 0 0 0 0
16 25 1005 1005 1005 1005 0 0 0 0 0 0 0 0 0
16 30 1206 1206 1206 1206 0 0 0 0 0 0 0 0 0
16 35 1407 1407 1407 1407 0 0 0 0 0 0 0 0 0
16 40 1608 1608 1608 1608 0 0 0 0 0 0 0 0 0
16 45 1809 1809 1809 1809 0 0 0 0 0 0 0 0 0
16 50 2010 2010 2010 2010 0 0 0 0 0 0 0 0 0
16 55 2211 2211 2211 2211 0 0 0 0 0 0 0 0 0
16 60 2412 2412 2412 2412 0 0 0 0 0 0 0 0 0
16 65 2613 2613 2613 2613 0 0 0 0 0 0 0 0 0
16 70 2814 2814 2814 2814 0 0 0 0 0 0 0 0 0
20 15 875 875 875 875 0 0 0 0 0 0 0 0 0
20 20 1005 1005 1005 1005 0 0 0 0 0 0 0 0 0
20 25 1256 1256 1256 1256 0 0 0 0 0 0 0 0 0
20 30 1508 1508 1508 1508 0 0 0 0 0 0 0 0 0
20 35 1759 1759 1759 1759 0 0 0 0 0 0 0 0 0
20 40 2010 2010 2010 2010 0 0 0 0 0 0 0 0 0
20 45 2261 2261 2261 2261 0 0 0 0 0 0 0 0 0
20 50 2513 2513 2513 2513 0 0 0 0 0 0 0 0 0
20 55 2764 2764 2764 2764 0 0 0 0 0 0 0 0 0
20 60 3015 3015 3015 3015 0 0 0 0 0 0 0 0 0
20 65 3266 3266 3266 3266 0 0 0 0 0 0 0 0 0
20 70 3518 3518 3518 3518 0 0 0 0 0 0 0 0 0
25 15 942 942 942 942 0 0 0 0 0 0 0 0 0
25 20 1256 1256 1256 1256 0 0 0 0 0 0 0 0 0
25 25 1570 1570 1570 1570 0 0 0 0 0 0 0 0 0
25 30 1884 1884 1884 1884 0 0 0 0 0 0 0 0 0
25 35 2198 2198 2198 2198 0 0 0 0 0 0 0 0 0
25 40 2513 2513 2513 2513 0 0 0 0 0 0 0 0 0
25 45 2827 2827 2827 2827 0 0 0 0 0 0 0 0 0
25 50 3141 3141 3141 3141 0 0 0 0 0 0 0 0 0
25 55 3455 3455 3455 3455 0 0 0 0 0 0 0 0 0
25 60 3769 3769 3769 3769 0 0 0 0 0 0 0 0 0
25 65 4083 4083 4083 4083 0 0 0 0 0 0 0 0 0
25 70 4397 4397 4397 4397 0 0 0 0 0 0 0 0 0
32 15 1206 1206 1206 1206 0 0 0 0 0 0 0 0 0
32 20 1608 1608 1608 1608 0 0 0 0 0 0 0 0 0
32 25 2010 2010 2010 2010 0 0 0 0 0 0 0 0 0
32 30 2412 2412 2412 2412 0 0 0 0 0 0 0 0 0
32 35 2814 2814 2814 2814 0 0 0 0 0 0 0 0 0
32 40 3216 3216 3216 3216 0 0 0 0 0 0 0 0 0
32 45 3618 3618 3618 3618 0 0 0 0 0 0 0 0 0
32 50 4020 4020 4020 4020 0 0 0 0 0 0 0 0 0
32 55 4422 4422 4422 4422 0 0 0 0 0 0 0 0 0
32 60 4824 4824 4824 4824 0 0 0 0 0 0 0 0 0
32 65 5226 5226 5226 5226 0 0 0 0 0 0 0 0 0
32 70 5628 5628 5628 5628 0 0 0 0 0 0 0 0 0
10 15 875 875 875 875 0 0 0 0 0 0 0 0 0
DESIGN TABLE TO BS8007 - SERVICE AND ULTIMATE MOMENT CAPACITY BY IR. T.C. LIM DESIGN TABLE B1
Crack width, w= 0.2 mm Modulus of elasticity of steel, Es = 200 kN/mm²
Concrete cover, c= 40 mm Modulus of elasticity of concrete, Ec = 13.28 kN/mm² where Ec = [ 5.5*SQRT(fcu/1.5) ]/2
Concrete grade, fcu = 35 N/mm² Modular ratio, a = Es/Ec a= 15.06
Steel grade, fy = 460 N/mm²
Slab (h) Slab Thickness(h), Service Moment(Ms) & Ultimate Moment(Mult) in kNM
Reinforcement 550 700 625 100 100 50 50 50 50 50 50 50 50
Dia. c/c As Ms Mult Ms Mult Ms Mult Ms Mult Ms Mult Ms Mult Ms Mult Ms Mult Ms Mult Ms Mult Ms Mult Ms Mult Ms Mult
10 100 785 0 0 0 0 0 0 6 14 6 14 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
10 125 628 0 0 0 0 0 0 5 12 5 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
10 150 524 0 0 0 0 0 0 5 10 5 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
10 175 449 0 0 0 0 0 0 4 9 4 9 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
10 200 393 0 0 0 0 0 0 4 8 4 8 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
12 100 1131 179 217 262 281 219 249 7 16 7 16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
12 125 905 151 173 0 0 186 199 6 15 6 15 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
12 150 754 0 0 0 0 0 0 6 13 6 13 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
12 175 646 0 0 0 0 0 0 5 12 5 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
12 200 565 0 0 0 0 0 0 5 11 5 11 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
12 225 503 0 0 0 0 0 0 4 10 4 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
12 250 452 0 0 0 0 0 0 4 9 4 9 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
12 275 411 0 0 0 0 0 0 4 8 4 8 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
12 300 377 0 0 0 0 0 0 4 7 4 7 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
16 100 2011 254 383 361 498 306 441 9 15 9 15 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
16 125 1608 204 307 294 399 247 353 8 15 8 15 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
16 150 1340 173 256 252 332 211 294 7 15 7 15 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
16 175 1149 152 219 224 285 187 252 7 15 7 15 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
16 200 1005 138 192 205 249 170 221 6 15 6 15 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
16 225 894 128 171 0 0 158 196 6 15 6 15 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
16 250 804 0 0 0 0 0 0 5 13 5 13 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
16 275 731 0 0 0 0 0 0 5 12 5 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
16 300 670 0 0 0 0 0 0 5 12 5 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
20 100 3142 348 578 487 767 416 673 10 14 10 14 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0
20 125 2513 273 471 384 621 327 546 9 14 9 14 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0
20 150 2094 225 397 319 518 271 458 8 14 8 14 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0
20 175 1795 193 341 276 444 233 392 8 14 8 14 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0
20 200 1571 171 299 246 388 207 343 7 14 7 14 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0
20 225 1396 154 265 225 345 188 305 7 14 7 14 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0
20 250 1257 142 239 209 311 174 275 6 14 6 14 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0
20 275 1142 133 217 197 282 163 250 6 14 6 14 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0
20 300 1047 126 199 188 259 155 229 6 14 6 14 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0 #DIV/0! 0
25 100 4909 491 855 680 1149 584 1002 10 12 10 12 47 -5 47 -5 47 -5 47 -5 47 -5 47 -5 47 -5 47 -5
25 125 3927 378 703 524 939 450 821 10 12 10 12 27 -4 27 -4 27 -4 27 -4 27 -4 27 -4 27 -4 27 -4
25 150 3273 306 597 425 794 364 695 9 12 9 12 17 -3 17 -3 17 -3 17 -3 17 -3 17 -3 17 -3 17 -3
25 175 2805 257 518 359 687 306 603 9 12 9 12 12 -3 12 -3 12 -3 12 -3 12 -3 12 -3 12 -3 12 -3
25 200 2454 222 458 312 604 266 532 8 12 8 12 9 -2 9 -2 9 -2 9 -2 9 -2 9 -2 9 -2 9 -2
25 225 2182 197 410 279 537 236 475 8 12 8 12 7 -2 7 -2 7 -2 7 -2 7 -2 7 -2 7 -2 7 -2
25 250 1964 178 371 254 483 214 427 7 12 7 12 5 -2 5 -2 5 -2 5 -2 5 -2 5 -2 5 -2 5 -2
25 275 1785 163 338 235 439 197 389 7 12 7 12 4 -2 4 -2 4 -2 4 -2 4 -2 4 -2 4 -2 4 -2
25 300 1636 152 309 220 403 184 356 7 12 7 12 3 -2 3 -2 3 -2 3 -2 3 -2 3 -2 3 -2 3 -2
32 100 8042 729 1261 1011 1744 868 1503 9 11 9 11 127 -18 127 -18 127 -18 127 -18 127 -18 127 -18 127 -18 127 -18
32 125 6434 557 1062 767 1448 661 1255 9 11 9 11 72 -15 72 -15 72 -15 72 -15 72 -15 72 -15 72 -15 72 -15
32 150 5362 445 914 611 1236 527 1075 9 11 9 11 45 -12 45 -12 45 -12 45 -12 45 -12 45 -12 45 -12 45 -12
32 175 4596 368 801 505 1077 435 939 8 11 8 11 30 -10 30 -10 30 -10 30 -10 30 -10 30 -10 30 -10 30 -10
32 200 4021 313 713 430 954 370 833 8 11 8 11 22 -9 22 -9 22 -9 22 -9 22 -9 22 -9 22 -9 22 -9
32 225 3574 273 642 376 856 323 749 8 11 8 11 16 -8 16 -8 16 -8 16 -8 16 -8 16 -8 16 -8 16 -8
32 250 3217 242 583 335 776 287 680 7 11 7 11 12 -7 12 -7 12 -7 12 -7 12 -7 12 -7 12 -7 12 -7
32 275 2925 219 535 304 710 260 622 7 11 7 11 10 -7 10 -7 10 -7 10 -7 10 -7 10 -7 10 -7 10 -7
32 300 2681 200 493 279 654 238 574 7 11 7 11 8 -6 8 -6 8 -6 8 -6 8 -6 8 -6 8 -6 8 -6